  • 8/8/2019 M26 Anti Fouling

    1/33

    Corrpro

    Companies

    Europ e Limited

    A Comm itment to Excellence

    Adam Street, Bowesfield Lane

    Slockton-on-Tees

    Cleveland TS18 3HQ. England

    Tel:  (01642 )61410 6 Telex: 587388

    Fax:(01642)614100

  • 8/8/2019 M26 Anti Fouling

    2/33

    ANFOMATIC MANUAL DOC:

      G 04/02

    PAGE:  OF 41

    REV: 05

    ANFOMATIC

    ANTI-FOULING AN D CORRO SION

    RPEVENTION SYSTEM

    FINNAL DRAWING

  • 8/8/2019 M26 Anti Fouling

    3/33

    ANFOMATIC INSTRUCTION MANUAL DOC:

      G 04/02

    PAGE:  OF 25

    REV: 8

    ANFOMATIC

  • 8/8/2019 M26 Anti Fouling

    4/33

    ANFOMATIC INSTRUCTION MANUAL DOC : G.04/02

    PAGE: 2 OF 25

    REV: 8

    INDEX

    1.0 INTRODUCTION

    1.1 Gene ral System Description

    1.2 Safety Preca utions

    2.0 MATERIALS AND EQUIPMEN T

    2.1 Electrical

    2.1.1 Pow er Control Unit

    2.1.2 Electric Cable

    2.1.3 Junction Box

    2.2 Alloy Anodes

    3.0 INSTALLATION INSTRU CTIONS

    3.1 Power Control Unit

    3.2 Connecting Cables/Junction Boxes

    3.3 Anode/Cofferdam/Flange

    3.4 Anode Replacement Procedure

    4.0 COMMISSIONING

    5.0 OPERATION & DISPLAY S

  • 8/8/2019 M26 Anti Fouling

    5/33

    ANFOMATIC INSTRUCTION MANUAL DO C: G.04/02

    PAGE: 3 OF 25

    REV: 8

    1.0 INTRODUCTION

    1.1 General System Description

    Principle of Operation.

    Marine fouling and biological fouling commonly occur in seawater circulation

    systems. This involves the establishment of marine plants and animals, and bacterial

    growths. These fouling organisms enter the system in microscopic and macroscopic

    form, e.g. larvae and spats, settle and develop into adult forms wherever favourable

    environmental conditions exist.

    Hard fouling by mussels, barnacles etc. most commonly occurs in seawater circuits

    and can result in interference in flow conditions, blockage and increased corrosion.

    Traditional chemical methods of water treatment to prevent fouling are now less

    favoured particularly, for example, chlorination. Chlorine accelerates corrosion rates,

    usually by causing pitting attack on steel, is environmentally unacceptable and

    treatment requires continuous m onitoring an d control.

    The Anfomatic System.

  • 8/8/2019 M26 Anti Fouling

    6/33

    ANFOM ATIC INSTRU CTION MANUAL DO C: G.04/02

    PA GE : 4 OF 25

    RE V: 8

    1.2 Gen eral Safety Precautions for Electrical Equipm ent

    The following is given as a guideline only and the operators own safety rules

    and regulations should be followed at all times.

    Non-energised Equipment

    1. Isolate the supply, carry ou t the Tag Ou t system drill or equivalent as

    specified by the operators own safety procedures.

    2.  Obtain an approved voltage tester and check it against a know n good

    power supply. Test the equipm ent circuits across all lines and between

    each line and earth to ensure that it has been isolated from its power

    supply before you touc h it. Check the tester again after u se.

    3.  Ensure that any capac itors associated with the equ ipm ent are fully

    discharged, fitting shorting straps if necessary.

    Energised Equipment

  • 8/8/2019 M26 Anti Fouling

    7/33

    ANFOM AT IC INST RUCT ION MANUAL DO C: G.04 /02

    PA GE : 5 OF 25

    RE V: 8

    2.0 MATERIALS AND EQUIPMENT

    2.1 Electrical

    2.1.1 Power Control Units

    2.1.2 Electric Cable

    2.1.3 Junction Box

    2.1.1 Controller Pow er Units.

    The Mk IV modular control unit is a variable voltage, constant current unit designed

    for single-phase input power supplies of between 90v to 260v or 350 to 450v AC at

    50-60Hz and is available in two cabinet sizes. The smaller cabinet (AM ll5 8/ 14 ) can

    accommodate between one and five control modules with the larger cabinet

    (AM I 158/13) being able to accommodate between six and ten. Eac h two-channel

    control module is rated at a maximum 65-Watts power output with each output

    channel having a m aximum output of 3.5 amp s DC at 12 volts.

    Refer to drawings AM I 158/14 & A M I 158/13.

  • 8/8/2019 M26 Anti Fouling

    8/33

    ANFOMATIC INSTRUCTION MANUAL DO C: G.04/02

    PAGE: 6 OF 25

    REV: 8

    2.1.2 Cable

    (a) Input

    All input cables and shrouds are of shipyard supply. Fittings, term inations,

    glands, etc are also usually of shipyard supply. The AC supply cable size is

    rated according to the maximum DC output of the power unit. Usually, a very

    small conductor size is adequate but for physical and electrical reasons, it is

    preferable to use a larger cable conductor size than the nominal current

    capacity needed. Cable insulation, armouring and sleeving is dictated by ship

    classification requirements.

    Input cable size of minimum cross-section 4 sq. mm per conductor is

    recommended.

    e.g. 3 X 4 sq. mm PVC/PVC/SW A/PVC

    (b) P .C . Output

    The positive DC output from each channel is connected to a corresponding

  • 8/8/2019 M26 Anti Fouling

    9/33

    ANFOMAT IC INST RUCT ION MANUAL

    D O C :

      G.04/02

    PA GE : 7 OF 25

    R E V : 8

    2.1.3 Junction Bo xes (Optional Supply)

    An intermediate junction box facilitates separation of individual anodes from the

    supply thus avoiding interference with the rest of the system during inspection or

    anode replacement.

    Junction bo xes should be intrinsically safe or have an IP rating to client specification.

    Corrpro Companies Europe supplies polymer enclosures rated to IP65 for two, four

    and six anode arrangements in each sea chest.

    Refer to Drawings AM 1513, AM1514 & A M1515.

    2.2 Alloy Anod es

    A typical anode assembly, complete with cofferdam and mounting flange is shown in

    drawing No . AM I500 . The anode can be separated from the cofferdam and flange as

    shown in drawing A M I503

    Anode size and material type is indicated by an alphanumeric code identifying the

    model, material & dimensions of each anode.

  • 8/8/2019 M26 Anti Fouling

    10/33

    ANFOMATIC INSTRUCTION AUNUAL DO C: G.04/02

    PAG E: 8 OF 25

    REV: 8

    3.0 INSTALLATION INSTRUCTIONS

    3.1 Installation of the Power Control Unit

    3.2 Conn ecting Cables & Junction Boxe s

    3.3 An ode s, Cofferdams & Flanges

    3.1 Power Con trol Unit

    The control panel should be located as near as possible to a suitable AC power supply

    and the anode locations in order to minimise the DC cable length and voltage drop.

    The control panel location should m eet the following requirem ents:

    (a) M ax. ambient temperature of 50 deg. C. (Unit rated to 55 deg. C) .

    (b) Ad equ ate space around unit to assist ventilation.

    (c) Ap prox . head height to faciHtate ease of reading display, current adjustment in

  • 8/8/2019 M26 Anti Fouling

    11/33

    ANFOMATIC INSTRUCTION MANUAL DO C: G.04/02

    PAGE: 9 OF 25

    REV: 8

    3.3 Ano des, Cofferdams and Flanges

    Where possible, anodes should be installed in the position specifically shown or

    advised for each vessel.

    The anodes are installed in the selected compartments, usually sea chests, injection

    strainers, crossover channels or specially designed reaction vessels.

    (a) The agreed positio ns for the apertu res for the cofferdam entry poi nts should be

    clearly marked and burnt or cut out taking precautions to protect surrounding

    equipment with heat resistant blankets etc. A stand-by fire extinguisher and

    fire sentry should be provided.

    (b) The mating flange to receive the anode and cofferdam flange should be welded

    in position with continuous welds on both inside and outside joints and

    inspected by the relevant certifying authority at the time of installation.

    (c) To provide a connection point for the negative retum , a screw or suitable

    alternative connection can be welded onto the sea chest mounted flange or to

    any other convenient location in direct and continuous electrical contact with

  • 8/8/2019 M26 Anti Fouling

    12/33

    ANFOMA TIC INSTRU CTION MANUAL DO C: G.04/02

    PAG E : 10 OF 25

    RE V: 8

    (h) Secure anode cables and negative single cable together and take back for

    connection in the junction b ox.

    Anode Type Cofferdam Colour Cable Colour

    WW Cuproline Blue Red

    WW Aloline Silver Grey Black

    WW Ferroline Black Black

    No te: Cable colour scheme is indicative only and refers only to Corrpro

    Com panies (Europe) Ltd. standard supply cable. Where client

    specified cable is supplied it may not be possible to match this colour

    scheme.

    (i) W hen vessel is afloat, carry out leakage tests by checking for ingress of water

    into the cofferdam.

    3.4 Anode Replacem ent Procedure

    Power to the anodes mu st be switched off before carrying out the following procedu re.

  • 8/8/2019 M26 Anti Fouling

    13/33

    ANFOMAT IC INST RUCT ION MANUAL DO C: G.04 /02

    PA GE : 11 OF 25

    RE V: 8

    (k) Us ing a suitable test meter ensure that the anode is electrically isolated from

    the cofferdam mounting.

    (1) Loc ate com plete assembly in the sea chest and secure with the eight (8)

    cofferdam flange nuts. Ensure gasket is in position and tighten down evenly.

    (m) Conn ect anode positive cable, re-fit lid and tighten cable gland.

    A specific d ata sheet for each vessel stating ano de sizes, locations and operating conditions is

    provided (Section 7.0). This data sheet is for completion on board by the vessel's engineers

    after installation and testing of the equipment has been carried out. All anodes are designed

    with a +20% margin allowing for overrun and higher current settings if required.

  • 8/8/2019 M26 Anti Fouling

    14/33

    ANFOMAT IC INST RUCT ION MANUAL

    DOC: G.04/02

    PA GE : 12 OF 25

    R E V : 8

    4.0 COMM ISSIONING AND FAULT FINDING

    4.1 Commissioning

    (ONLY TO BE CARRIED OUT WH EN THE VESSEL IS AFLO AT)

    a) Check all cable connections at pow er control unit, terminal box and a nodes.

    b) Identify each positive output and relevant anode, and record the same .

    c) Switch on AC supply and then the pane l on/off switch.

    e) Adjust output to the recommended current values on each anode.

    4.2 Fault Findin g

    FAULT

    LCD display on one module

    fails to illuminate.

    PROBABLE CAUSE

    Faulty module.

    REMED IAL ACTION

    Exchange module with

    another that is known to be

    working. If fault remains on

  • 8/8/2019 M26 Anti Fouling

    15/33

    ANFOMATIC INSTRUCTION MANUAL DO C: G.04/02

    PAGE:  3 OF 25

    REV: 8

    5.0 OPERATION & DISPLAYS

    Each M k IV plug-in module controls two individual output channels. The Mk V and

    VI models have a fixed number of output channels with displays configured in the

    same way as the modular units.

    The new style Power Module has a new look front plate that comprises of a graphic

    LCD display and four control buttons. The b uttons function left to right as follows:

    Function: Symbol

    Cancel or Exit M enu

    U p or Increase

    Down ' or Decrease

    OK or Enter

    The Main Screen.

    < -

    t

    i

    J

    On initial power up the LCD will display the manufacturers logo for a period of 4

  • 8/8/2019 M26 Anti Fouling

    16/33

    ANFOMAT IC INST RUCT ION MANUAL DO C: G.04 /02

    PA GE : 14 OF 25

    RE V: 8

    The Status menu screen.

    This screen will display a menu of three items,

      OPTIONS , HOUR COUNTS

    and

      VOLTAGES .

      The module software version is also displayed in the bottom

    right comer of the screen.

    The user can move through the menu using the

      UP

    an d

      DOWN

    buttons to

    highlight each menu item and then press

      ENTER

    to select the function.

    Pressing CA N CE L or not pressing a button for 4 min utes will return to the main

    screen.

    The Options menu

    The Options menu shows a further five items to allow the user to set the shutdown

    current percentage, material identifier an d shutdown inpu t.

    In each of the

      Shutdown

      screens the

      UP

      and

      DOWN

    buttons can be used to set

    the percentage of the normal current that should flow when the module shutdown

    input is connected to ground or the manual shutdown is selected. Pressing   ENTER

    is required to confirm changes.  CANCEL will discard the changes and return to the

  • 8/8/2019 M26 Anti Fouling

    17/33

    ANFOMAT IC INST RUCT ION MANUAL DO C: G.04 /02

    PA GE : 15 OF 25

    RE V: 8

    The Voltages screen

    This screen shows anode voltages, the module internal temperature and the total

    power consumption for that mo dule. Voltages are accurate to O.IV, the module

    temperature is accurate to 5 C and the po we r is in watts.

    Pressing CA N CE L will return to the Status menu.

    Shutdown Operation

    Each modu le can be set to respond to either manual control or a remote inpu t signal.

    If

      Manual

    shutdown mode is selected then the

      UP

    an d

      DOWN

    buttons can be

    used to go between normal operation (UP) and shutdown mode (DOW N).

    If Signal shutdown mode is selected then the module will only respond to an

    external input signal such as pump ruiming/pum p stopped . In this m od e

      UP

    and

    DOWN for selecting between normal runnin g and shutdown are disabled

    The selected setting is stored even if power to the module is rem oved.

  • 8/8/2019 M26 Anti Fouling

    18/33

    ANFOMAT IC INST RUCT ION MANUAL DO C: G.04 /02

    PA GE : 16 OF 25

    R E V : 8

    6.0 MAINTENANCE

    The maintenance requirement for the Anfomatic system is minimal. The system

    operates at constant current output and does not therefore require adjustment unless

    the operational requirements specifically require regular adjustments to b e made .

    A w eekly recording of current outputs on each anode is recomm ended for which a log

    sheet is provided as enclosed.

    This provides a record of the system's operation, an indication of any changes in

    fiinction and a reminder when anode replacements are scheduled.

    A complete loss of current on any anode should be investigated by checking all cable

    connections, power panel fiises or by interchanging modules.

    Regular electrical maintenance should be carried out according to the operators own

    procedures and planned maintenance system.

    Anodes should be replaced at the end of their designed life span or during each dry

    docking of the vessel according the procedure laid down in the m anual.

  • 8/8/2019 M26 Anti Fouling

    19/33

    A N F O M A T IC I N S T R U C T IO N M A N U AL D O C :   G 04/02

    PA G E : 17 OF 25

    R E V : 8

    7.0 SPECIFIC VESSEL DETAILS

    (To be completed on board at time of commissioning by appointed engineer)

    PROJECT REFERENCE NUMBER

    VESSEL NAME

    INSTALLATION DETAILS

    POWER CON TROL UNIT

    AC INPUT CABLE

    PANEL EARTH CABLE

  • 8/8/2019 M26 Anti Fouling

    20/33

    ANFOMATIC INSTRUCTION M ANUAL

    7.0 SPECIFIC VESSEL DETAILS Cont.

    DOC:

      G 04/02

    PAGE:  8 OF 25

    REV: 8

    PROJECT REFERENCE NUMBER

    VESSEL NAME

    INSTALLATION DETAILS

    INSTALLATION DATE/LOCATION

    OPERATION PERIOD

    ORDER

     DATE

     FOR REPLACEMENT ANODES

  • 8/8/2019 M26 Anti Fouling

    21/33

    ANFOMATIC INSTRUCTION MANUAL DO C: G.04/02

    PAG E: 19 CF 25

    R EV : 8

    8.0 DRAW ING SCHEDULE

    1. AM 1164 Anfomatic General Arrange men t

    2.  AM 1158/14 Modular Controller Pow er Unit Mk IV (2-10 channels)

    3.

      AM 1167 Modular CPU Terminal Connec tions (M k IV units only, 2-10 channel)

    4.

      AM 1500 Anode General Assembly.

    5.

      AM 1501 Anode General Arrangem ent

    6. AM 1514 Junction Box Detail Type 2 (4 Anodes)

  • 8/8/2019 M26 Anti Fouling

    22/33

    ANFOMATIC INSTRUCTION MANUAL DOC:

      G 04/02

    PAGE: 20 OF 25

    REV: 08

    9.0 LOG DATA SHEET

    See over.

  • 8/8/2019 M26 Anti Fouling

    23/33

    ANFOM AT IC INST RUCT ION MANUA L

    Corrpro

    Companies

    Europe Limited

    A Comm itment to Excellence

    Adam Street, Bowesfield Lane

    Stockton on Tees, Cleveland. TS 18 3 HQ

    Telephone (01642) 614106 (8 lines)

    Telex 587388

    Fax (01642) 614100

    Anfomatic System Log

    DOC:

      G 04/02

    PAGE:

      21 OF 25

    REV: 08

    Vessel

    Anode

    1

    2

    3

    4

    5

    Ship Owner

    Month

    CPU Serial Number

    Amperage R eading

    W e e k l Week 2

    Weeks

    Week 4 Week 5

    Anode Location

  • 8/8/2019 M26 Anti Fouling

    24/33

    ANFOMATIC INSTRUCTION MANUAL

    10.0 NOTES

    D O C :

    PA GE:

    REV:

    G 04/02

    22 OF 25

    08

  • 8/8/2019 M26 Anti Fouling

    25/33

    ANFOM ATIC INSTRUCTION MANUAL DO C: G.04/02

    PAGE: 23 OF 25

    REV: 08

    10.0 NOTES Cent.

  • 8/8/2019 M26 Anti Fouling

    26/33

    ANFOMATIC INSTRUCTION >UNUAL

    DOC:

    PAGE:

    REV:

    G 04/02

    24 O 25

    08

    APPEND IX 1.

    SPARE PARTS LIST

    ITEM: Part. N o.

    Power U nit:

    Power Unit Complete

    State CP U serial N o.

    CPU Step Down Transformer

    Module Transformer.

    Plug in Mod ule.

    Power Failure Relay Kit

    Door Key

    3 Amp Fuse

    5 Amp Fuse

    Indicator Lamp Bulb

    AN-CPU(TRl)

    AN-CPU(TR2)

    AN-CPU(M)

    AN-CPU(PFA)

    AN-CPU(K)

    AN-CPU(F3)

    AN-CPU(F5)

    AN-CPU(IL)

  • 8/8/2019 M26 Anti Fouling

    27/33

    ANFOMATIC INSTRUCTION MANUAL

    DOC:

      G.04/02

    PAG E: 25 OF 25

    REV: 08

    Anode Installation C ables:

    Positive Anti-fouling An ode Supply Cab le (5 meter)

    Positive Anti-corrosion A node Supply Cable (5 meter)

    CXP006R

    CXP006B

    The Following Items supplied as part of complete or replacement an ode assemb lies:

    Heat Shrink Sleeve AM 1500/4

    Nitrile Gasket A M 1500/6

    Rigid PVC Washer AM I500 /7

    Rigid Sleeve AM 1500/8

    Phenolic Resin Washer A M I 500/9

    Galvanised Washer A M I 500/11

    Galvanised Full Nut AM 1500/12

    Galvanised Lock Nut A M 1500/13

    6mm^ X M .8 Brass Terminal AM 1500/14

    High Tensile Support Stud A M 1500/23

    Galvanised Spring Washer AM I500 /24

    M.8 Brass Screw & washer AM 1500/25

  • 8/8/2019 M26 Anti Fouling

    28/33

    D.C. OUTPUT

    A.C.

      INPUT

    POWER CONTROL

    UNIT

    É , É

    JUNCTION BOX

    ORG No AMI 178

    3 CORE CABLE

    EPR/CSP/GSWB/CSP

    K

    JUNCTION BOX

    ORG.  No. AM1178

    ^ I

      W

    SEA CHEST 2

    ANTI-FOULING

    ANTI-CORROSION

    r

    L

    n

    CORE

    EARTH (SEA CHEST)

    ANTI-CORROSION

    ANTI-FOULING

    J

    REDRAWN IN CAD

    DESCRIPTION

    DCR

    No.

    DATE

    \ W

    ilson Walton International (UK) Ltd.

    a corrpro company

    Adam Street,BowesHeld Lane,

    Stockton-on-Tees,Cleveland TS18 3HQ.

    Tel:  (01642) 614106. Fax: 614100 Telex: 587388

    WILSON WALTON

    Informat ion shown on this drawing is conf ident ial and must not be co pied or conveyed to third part ies

    without the express permission of Wilson Walton Internat ional (UK)Ltd.

    Certain I tems shown on this drawing are subject to worldwide patent applicat ions.

    ANFOMATIC GENERAL ARRANGEMENT

    SP

    NTS

    • 2 5 / 2 / 9 8

    AH

    AM I 164

    ' 2 5 / 2 / 9 8

    00

  • 8/8/2019 M26 Anti Fouling

    29/33

    * -

    O o

    £1 £1

    st 0° t •C'08

    «MOC MODUU

    £t

    ^

    NOTES

    PANEL ENCLOSURE TO BE IP54

    UNIT TO BE MOUNTED ON HULL WITHOUT

    REMOVING ANY INTERNAL EQUIPMENT

    ALL DIMENSIONS IN mm.

    MODULE ASSEMBLY

    (VARIABLE - 10 WAY CONTROL SHOWN).

    CABLE ENTRY GLAND PLATE ON BOTTOM OF UNIT

    h-

    ' A ' l L -

    W l

    (L

    X

    -JTA

    T Y P E H

    2

      TO 10 WAY

     CONTROL

      2 1 2

    W

    6 0 0

    D

    4 0 2

    Wt.  -  CASE ONLY

    1 8 k q .

    FIXING HOLE CTRS.

    W1

    5 6 0

    H I

    1 3 4

    VIEW ON CABINET REAR

    cM|  _08HOLE

    120

    60

    (TYP)

    6No.  (820 HOLES

    -ih

      -ffi- - ^ - ^

      -S- -S-

    600

    A = = ^ f r ^

    GLAND PLATE. DETAIL

    18

    = K

    SECTION 'A-A' (TYP).

    ff

    orrpro

    Companies

    Europe Limited

    A  ommitmsDJt  to iso ülenc^

    Adam Street, Bowesfield Lane.

    Stockton-on-Tees,Cleveland TSl 8 3HQ.

    Tel;

      (01642) 614106. Fax: 614100 Telex: 587388

    Inlormation shown on Iti is drawing is

    conlidentia l and must not be copied

    or conveyed l o third parties without

    the express permission of Corrpro

    Companies Europe Ltd.

    Certain items shown on this drawing are

    subject to wor ldwide patent applications.

    ANFOMATIC SYSTEM

    MODULAR CONTROLLER POWER UNIT ASSEMBLY

    (IONIZING MPGS SYSTEM)

    RO

    NTS

    ' 1 3 / 6 / 0 3

    AH

    A M 1 1 5 8 / 1 4

    1 3 / 6 / 0 3

    01

  • 8/8/2019 M26 Anti Fouling

    30/33

    ANODE CONNECTION DETAILS FOR UP TO 10 WAY CONTROL PANEL

    1 2 3 4 5 6 7 8 9 10

    1 ^ ^ 3 ^ S 4 ^ ^ 5 ^ 2

    • f • •

    -lllh

    10 -

    9 -

    AC

    • ^

    • ^

    MAINS IN

    - E

    - N

    - L

    COMMON -VE

    FOR ALL ANODES

    •i- ^-

      I - I - I - • • •

      • •

      • •

    +

    UJ

    Q

    O

    +

    UJ

    a

    o

    +

    ro

    ÜJ

    O

    O

    +

    UJ

    C l

    o

    +

    ID

    Q

    O

    +

    CO

    UJ

    Q

    O

    +

    UJ

    Q

    o

    z:

    <

    +

    00

    Q

    O

    <

    +

    CD

    Q

    O

    +

    O

    UJ

    Q

    O

    01

    UPGRADED FROM 8 TO 10 WAY

    1007

    SP

    AH

    1/10/98

    REDRAWN IN CAD

    2 5 /3 /9 7

    DCR

    No.

    CHECK

    \aff

    ilson Walton International (UK) Ltd.

    a  corrpro company

    Adam Street ,Bowes(ieid Lane,

    Stockton-on-Tees,Cleveland TS18 3HQ.

    Tel:

      (01642) 614106. Fax: 614100 Telex: 587388

    WILSON WALTON

    Informat ion shown on this drawng is conf ident ial and must not

     be

     copie d or conveyed to third part ies

    without the express permission of Wilson Walton Internat ional (UK)Ltd.

    Certain items shown on this drawing are subject to worldwide patent applicat ions.

    ANFOMATIC SYSTEM

    M O D U L A R C . P . U . - A N O D E C O N N E C T I O N S

    Drawn

    DPS

    2 4 / 6 / 9 2

    PFR

    2 5 / 6 / 9 2

    NTS

    AM I 167

    01

  • 8/8/2019 M26 Anti Fouling

    31/33

    o

    n

    D

    t

    ^

     

    i

    C

    C

  • 8/8/2019 M26 Anti Fouling

    32/33

    ITEM

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    1

    DESCRIPTION

    COFFERDAM

    COFFERDAM LID

    HEAT SHRINK SLEEVE

    NITRILE GASKET

    RIGID   P.V.C.  WASHER

    ELECTRODE

    NITRILE GASKET

    M,16 WASHER

    M.16 NUT

    M.I 6 STUD X 6 0 LG .

    MOUNTING BOSS (SEE DETAIL)

    NOTES

    1) YARD TO CUT HOLE 130 DIA. IN TOP PLATE

    AND WELD ON MOUNTING BOSS AS SHOWN.

    2) REMOVE ALL BURRS  &  SHARP EDGES

    No .

      HOLES

    M l 6x2 0 DEEP

    NOTE.

    SPECIAL ATTENTION TO BE

    PAID DURING O UTFin iNG

    TO ENSURE THAT THE CABLE

    GLAND IN THE GOFFERDAM LID

    IS NOT DAMAGED

    NO T E: - ALL DIM ENSIO NS IN m m .

    MOUNTING BOSS DETAIL

    MATERIAL - MILD STEEL

    OCR

    No.

    ff

    orrp ro

    Companies

    Europe Limited

    for

      Every Comer of Your

     World

    Adam Street, Bowesfield Lane,

    Slocklon-on-Tees,Cleveland TSl 8 3HQ.

    Tel:

      (01642) 614106. Fax; 614100 Telex: 587388

    Information shown on this drawing is

    conr idenlia l and must not be copied

    or conveyed to third parties without

    the express permission of Corrpro

    Companies Europe Ltd.

    Certsun items shown on this drawing are

    subject to wor ldwide patent applications.

    ANFOMATIC ANODE

    GENERAL ARRANGEMENT

    RO

    1:2

    1 5 / 1 1 / 0 1

    AH

    AM1501

    1 5 / 1 1 / 0 1

    01

  • 8/8/2019 M26 Anti Fouling

    33/33

    148 CRS.

    4No. LID LOCATION HOLES

    FOR SPRING LOADED

    CAPTIVATED LOCKING

    SCREWS IN LID

    BRASS TERMINALS BLOCK BAR

    ELEVATION WITH COVER REMOVED

    NOTE : - ALL DIMENSIONS IN m m

    ABS JUNCTION BOX

    LENGTH - 160 mm

    WIDTH - 80mm

    DEPTH - 42mm

    M.25 ENTRY PLASTIC

    CABLE GLAND

    SUITABLE FOR

      3 CORE

    6mm2 EPR/CSP/GSWB/CSP CABLE

    4No. 04 FIXING HOLES

    TERMINALS BLOCK

    M.I 6 ENTRY PLASTIC

    CABLE GLAND. SUITABLE

    FOR 6mm2 SINGLE CORE

    XLPE/PVC/PVC

    DCR

    No.

    CHECK

    ff

    orrpro

    Companies

    Europe Limited

    For very  omer  of Your

      forW

    Adam Street,Bowesfield Lane,

    Stockton-on-Tees,Cleveland TS18 3HQ.

    Information shown on this drawing is

    confidential and must not t« copied

    or conveyed to third parties without

    the express permission of Corrpro

    Companies Europe Ltd.

    Certain items shown on this drawing are

    subject to w orldwide patent applications.

    Tel:

     (01642) 614106. Fax: 614100 Telex: 587388

    ANFOMATIC SYSTEM

    JUNCTION BOX DETAIL

    RO

    NTS

    4 / 1 1 / 0 2 AH

    AM1514

    1 1 / 1 1 / 0 2