Advantages�for�you�:•��Double�break�per�pole�facilitaling�suitability�for�isolation�as�per�

���IEC�60947-3

•��Safe�isolation�at�0�position�for�maintenance�

•��Compact�dimension�to�save�panel�space

•��Flexibility�to�mount�accessories�on�site

•��Voltage�free�stable�position�contact�(I,�0,�II)

•��Line�load�reversibility

•��Silver�plated�contact�for�long�life

Technical�data�:•��Complies�with�IEC�60947-3

•��Rating:�63A�-�1600A

•��Suitable�for�AC23

•��Lockable�position:�0

ManualChangeover�Switches63A to 1600A

Experttips

Quick switching operation by�spring�action�with�

sweeping�silver�contacts1

3 stable positionchangeoverwith�padlocking�at�zero�position

for�maintainance�on�direct�&�

extended�handle

2

3

Site mountable widerange�of�accessories�based�on

application�needs4

Compact dimension with�back�to�back�terminals

4

Manual�changeover�switches63�to�1600A

63A - 100A (HI403I & (HI405I)

HI403i HI405i HI451i HI452i HI453i HI454i HI455i HI456i HI458i HI460i HI461i HI462i HI464i

In 63�A 100�A 125�A 160�A� 200A� 250�A� 315A 400�A� 630�A� 800�A� 1000A 1250�A� 1600�A

insulation�voltage�Ui�(V)� 750 750 800 800� 800 800� 1000 800� 1000� 1000� 1000 1000� 1000

impulse�withstand�voltage�Uimp�(kV)� 6 6 8 8� 8 12� 12 8� 12� 12� 12 12� 12

Ie�AC�22A�/�22B,�400�V�(A)� 63 100 125 160� 200 250� 315 400� 630� 800� 1000 1250� 1600

Ie�AC�23A�/�23B,�400�V�(A)� 63 100 125 160� 200 250� 315 250� 500� 800� 1000 1250� 1600

operational�power�(kW)AC�23A�à�400�V� 30 30 63 80� 80 132� 132 220� 280� 450� 710 710� 710

short�circuit�current�with�gG�DIN�fuses�(kA)� 80 80 100 100� 50 50� 50 18� 70� 50� 100 100� 100

associated�fuse�rated�(A)� 63 100 125 160� 200 250� 315 400� 630� 800� 1000 1250� 2�x�800

rated�short�circuit�making�capacity�Icm�(kA�peak)� 15 15 12 12� 12 17� 22 15,3� 30� 48� 75 75� 86

rated�short�time�withstand�current�Icw�(kA/1s)� 5 5 7 7� 7 9� 9 9� 13� 26� 35 50� 50

mechanical�endurance�(cycles)� 10000 10000 10000 10000� 10000 10000� 10000 8000� 5000� 3000� 10000 4000� 4000

connection�for�lugs�(mm²)� 16 25 50 95� 120 150� 240 240� 2�x�300� 2�x�300� 4�x�185 4�x�185� 6�x�185

Technical characteristics

Dimensions diagram (in mm)

5

Manual�changeover�switches63�to�1600A

H B

F

J

A

K

G

C

D min.

45

E

18

140

125

I

11

A

F38

52

88

220

460

O

II

KKK

J

B B

C

D min.

61

E

18

210

240

800A - 1600A

125A - 630A

Rating A B C D E F G H J K L

HI451I 125A 251 135 218 208 148 186 101 235 20 36 -

HI452I 160A 251� 135� 218� 208� 148� 186� 101� 235� 20� 36� -

HI453I 200A 251� 160� 218� 208� 148� 246� 116� 280� 20� 50� -

HI454I 250A 312� 160� 218� 208� 148� 246� 116� 280� 25� 50� -

HI455I 315A 312� 170� 218� 208� 148� 246� 116� 280� 35� 50� -

HI456I 400A 312� 170� 218� 208� 148� 246� 116� 280� 35� 50� -

HI458I 630A 379� 260� 295� 285� 225� 306� 176� 400� 45� 65� -

HI460I 800A 460� 320� 374� 390� 302� 335� 220� 460� 50� 80� 609

HI461I 1000A 466� 321 375� 425� 298� 336� 250� 459� 50� 80� -

HI462I 1250A 592� 330� 374� 390� 302� 467� 220� 460� 60� 120� 741

HI464I 1600A 592� 360� 374� 390� 302� 467� 220� 460� 90� 120� 741

Dimensions (in mm)

6

Manual�changeover�switches63�to�1600A

Direct rotary handle

M

Bridgingbar

Mounting

Rating: 125A - 630A

Fixing of door interlock mechanism

Rating: 63A - 100A

7

Manual�changeover�switch�enclosures63�to�1600A

Enclosure for Manual Changeover Switch

Rating A B C K’OUT

VYE63M 63A 250 202 205 32

VYE100M 100A 250 202 205 32

VYE125M 125A 355 350 275 32

VYE160M 160A 355 350 275 32

VYE250M 250A 420 410 275 50

VYE400M 400A 420 410 275 50

VYE630M 630A 520 580 353 50

VYE800M 800A 610 680 538 50

VYE1000M 1000A 800 680 538 50

VYE1250M 1250A 800 680 538 50

VYE1600M 1600A 800 680 538 50

Dimensions (in mm)

Diagram:

#�Note:�Enclosures�are�supplied�assembled�together�with�Manual�Changeover�Switch

Advantages�for�you�:•��Manual�override�function�for��emergency�operations

•��Flexibility�to�have�line�load�reversibility�

•��Voltage�free�stable�position�contact�(I,�0,�II)�

•��Changeover�position�indicator

•��LED�indicator�of�power�ON�and�manual�override

•��Padlocking�facility�at�zero�position�in�manual�mode�for�

���maintainance

•��Emergency�stop�command�option�with�external�push�button

Technical�data�:•��Complies�with�IEC�60947-6-1

•��Rating:�125A�-�1600A

•��Suitable�for�AC33B

•��Lockable�position:�0

AutomaticTransfer�Switches125A to 1600A

Experttips

Padlocking facilityin�manual�mode�for�position

O1

Line loadreversibility2

4

5

Position indicator

Emergency manual operation�by�removable

handle3

Power ON and Manualoverride�indicator

Plug-in terminals6

Advantages�for�you�:•��Easy�parameter�display�using�remote�interface

•��Controller�with�On�/�Off�load�testing�facility

•��Controller�with�Genset�Start�/�Stop�option

•��Plugin�terminals�for�convenient�wiring

•��LED�indication�of�source�and�changeover�status

Features�:•��Voltage�monitoring

•��Frequency�monitoring

•��Phase�sequence�monitoring

•��No�auxiliary�supply�required

•��Security�access�codes�for�programming�and�testing

AutomaticTransfer�Switchescontroller

Experttips

Controller with LCD forparameter display for�easy�monitoring�and�flexibility

to�modify�parameters1

Genset Start / Stopfunctionenables�convenient�control

of�Genset�during�power�failure2

4

5

LED Indicationof�source�availability�and�

changeover�position

RJ45 port allows�easy�communication�

with�Remote�Interface3

Over / Under voltage,Over / Under frequencyPhase�sequence�monitoring�

and�adjustable�delay�timers

6ON-OFF load testingfacility�for�the�system

Automatic�transfer�switches125�to�1600A

12

HIB412I HIB416I HIB420I HIB425I HIB440I HIB463I HIB480I HIB490I HIB491I HIB492I

rated�current�In� 125�A� 160�A� 200A 250�A� 400�A� 630�A� 800�A� 1000�A� 1250�A� 1600�A

rated�insulation�voltage�Ui�(V)� 800� 800� 800 1000� 1000� 1000� 1000� 1000� 1000� 1000

rated�impulse�withstand�voltage�Uimp�(kV)� 8� 8� 8 12� 12� 12� 12� 12� 12� 12

Ie�AC�31B,�415�V�(A) 125� 160� 200 250� 400� 630� 800� 1000� 1250� 1600

Ie�AC�32B,�415�V�(A) - - - 200 400 500 800 1000 1250 1600

Ie�AC�33B,�415�V�(A)� - - - 200 200 400 800 1000 1250� 1000

short�circuit�current�with�gG�DIN�fuses�(kA)� 100� 100� 50 50� 50� 50� 50� 100� 100 100

associated�fuse�rated�(A)� 125� 160� 200 250� 400� 630� 800� 1000� 1250� 2�x�800

rated�peak�making�capacity�(kA�peak)� 20� 20� 20 30� 30� 45� 55� 55� 80� 110

rated�short�time�withstand�current�Icw�(kA/1s)� 7� 7� 7 8� 8� 10� 26� 35� 50� 50

mechanical�endurance�(cycles)� 10000� 10000� 10000 8000� 8000� 5000� 4000� 4000� 4000� 3000

lugs�connection�(mm²)�MAX 50� 95� 120 150� 240� 2�x�300� 2�x�300� 4�x�185� 4�x�185� 6�x�185

Technical characteristics

Automatic�transfer�switches125�to�1600A

Automatic transfer switches

==

250

M

T

51,5

280

C 21

13

HIB412I - HIB463I

HIB480I - HIB492I

125A 160A 200A 250A 400A 630A

J1 34 34 34 35 34 34

M 150 150 150 210 210 270

T 36 36 36 50 50 65

C 244 244 244 244 244 320

U 20 20 20 25 35 45

W 9 9 9 11 11 13

CA 10 10 10 15 15 20

Dimensions (in mm)

4P

1

Door cut-out for front panel

50.5

20138

150

Door cut-out for front panel

800A 1000A 1250A 1600A

M 335 335 335 467

T 80 80 80 120

C 391 391 391 523

Dimensions (in mm)

4P

Where

is my

nearest

Hager

contact

person?

©�javiindy�-�Fotolia.com

AlwaysNear

Our network to serve you better...

• 300+ Authorised Channel Partners• 35+ System Integrators

North

NCR

Haryana

Uttar Pradesh

Uttarakhand

1 North West

Punjab

Chandigarh

Himachal�Pradesh

J&K

Rajasthan

2 West

Greater�Mumbai

Gujarat

Goa

Madhya�Pradesh

3 Central

Maharashtra�

(without�Greater�Mumbai)

Chattisgarh

Telangana

Andhra�Pradesh

4

South

Tamilnadu

Pondicherry

Karanataka

Kerala

5 East

West�Bengal

Orissa

Bihar

Jharkhand

North�East

6 Nepal7 Bhutan8

ChennaiCoimbatore

Calicut

Cochin

Madurai

Trichy

Bangalore

Goa

Nagpur

Aurangabad

Surat

Vadodara

Ahmedabad

Rajkot

Jaipur

Jalandhar

Chandigarh

Ludhiana

Lucknow

Vizag

Hyderabad

Bhubaneshwar

Ranchi

Kolkata

Siliguri

Guwahati

Legends

Patna

Indore

Raipur

Sales�Office

Sales�Team

Factory

Warehouse

Export�Market

*�Product�development�is�an�continuous�process�and�hence�the�described�content�in�the�catalogue�are�subject�to�change�without�prior�notice.

Contact�your�nearest�Hager�Partner�for�the�latest�information.��

Hager Electro Private LimitedSales & Marketing office :Office�2A,�First�FloorNorth�Court�BuildingOpposite�Joggers�ParkKalyani�NagarPune-411006India

Delhi Sales Office :B�217�Tower�BDLF�Towers,�JasolaNew�Delhi-110025�India

Mumbai Sales Office :Office�#�1301A,�Tower�3Indiabulls�Finance�CentreElphistone�RoadMumbai-400013India

Hager Electro SAS:132�Boulevard�d`�EuropeBP�78F-67212�Obernai�France

Tel:� +91�20�41477500Fax:�+91�20�41477510Toll�free�no.:�1800�103�5440Email:�[email protected]�Website:�www.hager.co.in

Tel:� +91�11�49677500Fax:�+91�11�49677555

Tel:� +91�22�71813200