Advantages�for�you�:•��Double�break�per�pole�facilitaling�suitability�for�isolation�as�per�
���IEC�60947-3
•��Safe�isolation�at�0�position�for�maintenance�
•��Compact�dimension�to�save�panel�space
•��Flexibility�to�mount�accessories�on�site
•��Voltage�free�stable�position�contact�(I,�0,�II)
•��Line�load�reversibility
•��Silver�plated�contact�for�long�life
Technical�data�:•��Complies�with�IEC�60947-3
•��Rating:�63A�-�1600A
•��Suitable�for�AC23
•��Lockable�position:�0
ManualChangeover�Switches63A to 1600A
Experttips
Quick switching operation by�spring�action�with�
sweeping�silver�contacts1
3 stable positionchangeoverwith�padlocking�at�zero�position
for�maintainance�on�direct�&�
extended�handle
2
3
Site mountable widerange�of�accessories�based�on
application�needs4
Compact dimension with�back�to�back�terminals
4
Manual�changeover�switches63�to�1600A
63A - 100A (HI403I & (HI405I)
HI403i HI405i HI451i HI452i HI453i HI454i HI455i HI456i HI458i HI460i HI461i HI462i HI464i
In 63�A 100�A 125�A 160�A� 200A� 250�A� 315A 400�A� 630�A� 800�A� 1000A 1250�A� 1600�A
insulation�voltage�Ui�(V)� 750 750 800 800� 800 800� 1000 800� 1000� 1000� 1000 1000� 1000
impulse�withstand�voltage�Uimp�(kV)� 6 6 8 8� 8 12� 12 8� 12� 12� 12 12� 12
Ie�AC�22A�/�22B,�400�V�(A)� 63 100 125 160� 200 250� 315 400� 630� 800� 1000 1250� 1600
Ie�AC�23A�/�23B,�400�V�(A)� 63 100 125 160� 200 250� 315 250� 500� 800� 1000 1250� 1600
operational�power�(kW)AC�23A�à�400�V� 30 30 63 80� 80 132� 132 220� 280� 450� 710 710� 710
short�circuit�current�with�gG�DIN�fuses�(kA)� 80 80 100 100� 50 50� 50 18� 70� 50� 100 100� 100
associated�fuse�rated�(A)� 63 100 125 160� 200 250� 315 400� 630� 800� 1000 1250� 2�x�800
rated�short�circuit�making�capacity�Icm�(kA�peak)� 15 15 12 12� 12 17� 22 15,3� 30� 48� 75 75� 86
rated�short�time�withstand�current�Icw�(kA/1s)� 5 5 7 7� 7 9� 9 9� 13� 26� 35 50� 50
mechanical�endurance�(cycles)� 10000 10000 10000 10000� 10000 10000� 10000 8000� 5000� 3000� 10000 4000� 4000
connection�for�lugs�(mm²)� 16 25 50 95� 120 150� 240 240� 2�x�300� 2�x�300� 4�x�185 4�x�185� 6�x�185
Technical characteristics
Dimensions diagram (in mm)
5
Manual�changeover�switches63�to�1600A
H B
F
J
A
K
G
C
D min.
45
E
18
140
125
I
11
A
F38
52
88
220
460
O
II
KKK
J
B B
C
D min.
61
E
18
210
240
800A - 1600A
125A - 630A
Rating A B C D E F G H J K L
HI451I 125A 251 135 218 208 148 186 101 235 20 36 -
HI452I 160A 251� 135� 218� 208� 148� 186� 101� 235� 20� 36� -
HI453I 200A 251� 160� 218� 208� 148� 246� 116� 280� 20� 50� -
HI454I 250A 312� 160� 218� 208� 148� 246� 116� 280� 25� 50� -
HI455I 315A 312� 170� 218� 208� 148� 246� 116� 280� 35� 50� -
HI456I 400A 312� 170� 218� 208� 148� 246� 116� 280� 35� 50� -
HI458I 630A 379� 260� 295� 285� 225� 306� 176� 400� 45� 65� -
HI460I 800A 460� 320� 374� 390� 302� 335� 220� 460� 50� 80� 609
HI461I 1000A 466� 321 375� 425� 298� 336� 250� 459� 50� 80� -
HI462I 1250A 592� 330� 374� 390� 302� 467� 220� 460� 60� 120� 741
HI464I 1600A 592� 360� 374� 390� 302� 467� 220� 460� 90� 120� 741
Dimensions (in mm)
6
Manual�changeover�switches63�to�1600A
Direct rotary handle
M
Bridgingbar
Mounting
Rating: 125A - 630A
Fixing of door interlock mechanism
Rating: 63A - 100A
7
Manual�changeover�switch�enclosures63�to�1600A
Enclosure for Manual Changeover Switch
Rating A B C K’OUT
VYE63M 63A 250 202 205 32
VYE100M 100A 250 202 205 32
VYE125M 125A 355 350 275 32
VYE160M 160A 355 350 275 32
VYE250M 250A 420 410 275 50
VYE400M 400A 420 410 275 50
VYE630M 630A 520 580 353 50
VYE800M 800A 610 680 538 50
VYE1000M 1000A 800 680 538 50
VYE1250M 1250A 800 680 538 50
VYE1600M 1600A 800 680 538 50
Dimensions (in mm)
Diagram:
#�Note:�Enclosures�are�supplied�assembled�together�with�Manual�Changeover�Switch
Advantages�for�you�:•��Manual�override�function�for��emergency�operations
•��Flexibility�to�have�line�load�reversibility�
•��Voltage�free�stable�position�contact�(I,�0,�II)�
•��Changeover�position�indicator
•��LED�indicator�of�power�ON�and�manual�override
•��Padlocking�facility�at�zero�position�in�manual�mode�for�
���maintainance
•��Emergency�stop�command�option�with�external�push�button
Technical�data�:•��Complies�with�IEC�60947-6-1
•��Rating:�125A�-�1600A
•��Suitable�for�AC33B
•��Lockable�position:�0
AutomaticTransfer�Switches125A to 1600A
Experttips
Padlocking facilityin�manual�mode�for�position
O1
Line loadreversibility2
4
5
Position indicator
Emergency manual operation�by�removable
handle3
Power ON and Manualoverride�indicator
Plug-in terminals6
Advantages�for�you�:•��Easy�parameter�display�using�remote�interface
•��Controller�with�On�/�Off�load�testing�facility
•��Controller�with�Genset�Start�/�Stop�option
•��Plugin�terminals�for�convenient�wiring
•��LED�indication�of�source�and�changeover�status
Features�:•��Voltage�monitoring
•��Frequency�monitoring
•��Phase�sequence�monitoring
•��No�auxiliary�supply�required
•��Security�access�codes�for�programming�and�testing
AutomaticTransfer�Switchescontroller
Experttips
Controller with LCD forparameter display for�easy�monitoring�and�flexibility
to�modify�parameters1
Genset Start / Stopfunctionenables�convenient�control
of�Genset�during�power�failure2
4
5
LED Indicationof�source�availability�and�
changeover�position
RJ45 port allows�easy�communication�
with�Remote�Interface3
Over / Under voltage,Over / Under frequencyPhase�sequence�monitoring�
and�adjustable�delay�timers
6ON-OFF load testingfacility�for�the�system
Automatic�transfer�switches125�to�1600A
12
HIB412I HIB416I HIB420I HIB425I HIB440I HIB463I HIB480I HIB490I HIB491I HIB492I
rated�current�In� 125�A� 160�A� 200A 250�A� 400�A� 630�A� 800�A� 1000�A� 1250�A� 1600�A
rated�insulation�voltage�Ui�(V)� 800� 800� 800 1000� 1000� 1000� 1000� 1000� 1000� 1000
rated�impulse�withstand�voltage�Uimp�(kV)� 8� 8� 8 12� 12� 12� 12� 12� 12� 12
Ie�AC�31B,�415�V�(A) 125� 160� 200 250� 400� 630� 800� 1000� 1250� 1600
Ie�AC�32B,�415�V�(A) - - - 200 400 500 800 1000 1250 1600
Ie�AC�33B,�415�V�(A)� - - - 200 200 400 800 1000 1250� 1000
short�circuit�current�with�gG�DIN�fuses�(kA)� 100� 100� 50 50� 50� 50� 50� 100� 100 100
associated�fuse�rated�(A)� 125� 160� 200 250� 400� 630� 800� 1000� 1250� 2�x�800
rated�peak�making�capacity�(kA�peak)� 20� 20� 20 30� 30� 45� 55� 55� 80� 110
rated�short�time�withstand�current�Icw�(kA/1s)� 7� 7� 7 8� 8� 10� 26� 35� 50� 50
mechanical�endurance�(cycles)� 10000� 10000� 10000 8000� 8000� 5000� 4000� 4000� 4000� 3000
lugs�connection�(mm²)�MAX 50� 95� 120 150� 240� 2�x�300� 2�x�300� 4�x�185� 4�x�185� 6�x�185
Technical characteristics
Automatic�transfer�switches125�to�1600A
Automatic transfer switches
==
250
M
T
51,5
280
C 21
13
HIB412I - HIB463I
HIB480I - HIB492I
125A 160A 200A 250A 400A 630A
J1 34 34 34 35 34 34
M 150 150 150 210 210 270
T 36 36 36 50 50 65
C 244 244 244 244 244 320
U 20 20 20 25 35 45
W 9 9 9 11 11 13
CA 10 10 10 15 15 20
Dimensions (in mm)
4P
1
Door cut-out for front panel
50.5
20138
150
Door cut-out for front panel
800A 1000A 1250A 1600A
M 335 335 335 467
T 80 80 80 120
C 391 391 391 523
Dimensions (in mm)
4P
AlwaysNear
Our network to serve you better...
• 300+ Authorised Channel Partners• 35+ System Integrators
North
NCR
Haryana
Uttar Pradesh
Uttarakhand
1 North West
Punjab
Chandigarh
Himachal�Pradesh
J&K
Rajasthan
2 West
Greater�Mumbai
Gujarat
Goa
Madhya�Pradesh
3 Central
Maharashtra�
(without�Greater�Mumbai)
Chattisgarh
Telangana
Andhra�Pradesh
4
South
Tamilnadu
Pondicherry
Karanataka
Kerala
5 East
West�Bengal
Orissa
Bihar
Jharkhand
North�East
6 Nepal7 Bhutan8
ChennaiCoimbatore
Calicut
Cochin
Madurai
Trichy
Bangalore
Goa
Nagpur
Aurangabad
Surat
Vadodara
Ahmedabad
Rajkot
Jaipur
Jalandhar
Chandigarh
Ludhiana
Lucknow
Vizag
Hyderabad
Bhubaneshwar
Ranchi
Kolkata
Siliguri
Guwahati
Legends
Patna
Indore
Raipur
Sales�Office
Sales�Team
Factory
Warehouse
Export�Market
*�Product�development�is�an�continuous�process�and�hence�the�described�content�in�the�catalogue�are�subject�to�change�without�prior�notice.
Contact�your�nearest�Hager�Partner�for�the�latest�information.��
Hager Electro Private LimitedSales & Marketing office :Office�2A,�First�FloorNorth�Court�BuildingOpposite�Joggers�ParkKalyani�NagarPune-411006India
Delhi Sales Office :B�217�Tower�BDLF�Towers,�JasolaNew�Delhi-110025�India
Mumbai Sales Office :Office�#�1301A,�Tower�3Indiabulls�Finance�CentreElphistone�RoadMumbai-400013India
Hager Electro SAS:132�Boulevard�d`�EuropeBP�78F-67212�Obernai�France
Tel:� +91�20�41477500Fax:�+91�20�41477510Toll�free�no.:�1800�103�5440Email:�[email protected]�Website:�www.hager.co.in
Tel:� +91�11�49677500Fax:�+91�11�49677555
Tel:� +91�22�71813200