madison company product catalog
DESCRIPTION
ÂTRANSCRIPT
© Copyright Madison Company – 7/10
SINGLE-POINT LEVEL SENSORS & SWITCHES LL-1 TO LL-43• Stainless Steel Single-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-2 to LL-3• Plastic Single-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-4 to LL-5• Brass Single-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-6• Metric Single-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-7 to LL-8• Data Sheet/Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-9 to LL-10• Combination Level & Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-11 to LL-12• HVAC Condensate Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-13 to LL-14• Harsh Environment Level Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-15 to LL-16• Harsh Environment & High-Purity PTFE Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-17 to LL-18• Heavy-Duty Side-Mounted “Tank Commander” Level Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-19 to LL-20 • Heavy-Duty Industrial Side-Mounted “Big Dipper” Level Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-21 to LL-22 • Subminiature Liquid Level Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-23 to LL-24• Leak Detection Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-25 to LL-26• Bilge & Bottle Switches for Bilges and External Tank Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-27 to LL-28• Adjustable Height Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-29 to LL-30• Interstitial Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-31 to LL-32• Drum Level Indication Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-33 to LL-34• Refrigerant Recovery Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-35 to LL-36• Side-Mounted Switches with Male Spade Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-37 to LL-38• Tilt Float Switch for Open Vessels, Sumps & Ponds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-39 to LL-40• Stainless Steel Side-Mounted “Side Kick” Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-41 to LL-42• Single-Point Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-43
• Data Sheet/Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-45 to LL-46• Stainless Steel Multi-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-47• Plastic Multi-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-48• Brass Multi-Point Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-49• Multi-Point Switch Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-50• Full-Size Multi-Point Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-51• Miniature Multi-Point Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LL-52
• Field-Repairable Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL-2 to CL-6• 1-inch, 5mm & 10mm Transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL-2 to CL-8• 1-inch Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL-9• 5mm & 10mm Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CL-10• Continuous Level Sensors with Integrated Programmable Display & Alarm . . . . . . . . . . . . . . . . . CL-3, CL-11 to CL-12
• Probe for Food Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CD-1 to CD-2• Switches & Switch Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CD-3 to CD-4• Conductivity Switch Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CD-5
• Hydrostatic Pressure Level Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS-1 to PS-2• Hydrostatic Pressure Level Sensors for Turbulent Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS-3 to PS-4• Pressure Sensor with Integrated Programmable Display & Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS-5 to PS-6• Differential Pressure Transmitter with Integrated Programmable Display & Alarm . . . . . . . . . . . . . . . . . . . PS-7 to PS-8• Pressure Sensor Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS-9 to PS-10
• Optical Switch Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OP-1• Optical Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OP-2 to OP-4• Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OP-5 to OP-6• Optical Switch Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OP-7
TABLE OF CONTENTS
LL
MULTI-POINT LEVEL SENSORS & SWITCHES LL-45 TO LL-52
CONTINUOUS LEVEL INDICATORS CL-1 TO CL-12
CONDUCTIVITY LEVEL SWITCHES CD-1 TO CD-5
PRESSURE LEVEL SENSORS PS-1 TO PS-10
OPTICAL LEVEL DETECTION SWITCHES OP-1 TO OP-7
LL
CL
CD
PS
OP
FL
NC
TM
PR
AC
RF
© Copyright Madison Company – 6/10
FLOATS FL-1 TO FL-4
NON-CONTACT LEVEL SENSORS NC-1 TO NC-28
TEMPERATURE SENSORS TM-1 TO TM-20
PROXIMITY SENSORS PR-1 TO PR-3
ACCESSORIES AC-1 TO AC-10
TECHNICAL DATA & REFERENCE MATERIAL RF-1 TO RF-33
FL
NC
TM
PR
AC
RF
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.comMadison Europe • +31 (0) 548 659 034 • Fax +31 (0) 548 659 010 • E-mail: [email protected]
LL
LL
CL
CD
PS
OP
• Ultra-Low-Level Floats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FL-1 to FL-2• Standard Floats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FL-3 to FL-4
• U Series Ultrasonic Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-2 to NC-3• Madisonic™ Short-Range Ultrasonic Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-5 to NC-6• U4466 Series Programmable Ultrasonic Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-7 to NC-8• U4467 Series Loop-Powered Ultrasonic Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-9 to NC-10• U4468 Series Web-Enabled Ultrasonic Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-11 to NC-12• Standard Ultrasonic Sensors Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-13 to NC-14• Madison-Omni® Ultrasonic Sensors with Integrated Programmable Display & Alarm . . . . . . . . . . . . . . . NC-15 to NC-16• U3M Mini Ultrasonic Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-17 to NC-18• R Series Radar Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-4• Standard Radar Sensors Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-19 to NC-20• Sanitary “Smart” Radar Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-21 to NC-22• Non-Contact Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC-23 to NC-24
• Standard Part Numbers/Ordering Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-2 to TM-6 • Indicators & Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-7• Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-8• Type K, J & T Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-2, TM-9 to TM-10• RTDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-5, TM-11 to TM-12• Temperature Sensor Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-8, TM-13 to TM-14• RTDs with Integrated Programmable Display & Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-15 to TM-16• Thermistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-17 to TM-18• Bimetal Thermal Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-19 to TM-20• Temperature Sensor Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TM-21 to TM-22
• Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PR-1 to PR-2• Proximity Sensor Specification Work Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PR-3
• ESM & EZM Series Process Controllers, Indicators & Timers/Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC-1 to AC-2• R1 General-Purpose Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC-3 to AC-4• R2-120 & R2-220 Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC-5 to AC-6• PD765 Trident Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC-7 to AC-8• ED Series Loop Powered Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC-9 to AC-10
Liquid Level Switches• Material Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-1• General Product Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-2• Float Switch Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-3• Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-4 to RF-6• Switch Fittings & Stems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-7• Multi-Point Switch Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-8• Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-9 to RF-14
Non-Contact Sensors• Ultrasonic Level Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-15 to RF-16• Radar Level Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-17 to RF-19• Mounting Information & Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-20 to RF-21• Installation Guidelines & Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-22• Operation & Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-23 to RF-24• Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-25 to RF-26
Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-27 to RF-30
Thermocouple Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF-31 to RF-33
Please visit www.MadisonCo.com for Installation Manuals and additional product reference information.
Madison Company's comprehensive line of level sensors includessingle- and multi-point level switches, continuous level andconductivity sensors, non-contact sensors and more. The wideselection of materials offers reliable and durable level sensors for all liquid environments, as well as a full range of other applicationconditions. Madison engineers can incorporate temperature sensorsinto level sensor designs, offering combination sensing and costsavings for many applications.
• Hermetically sealed reed switches
• Various models operate at temperatures ranging up to 300˚C
• Units available to withstand pressures up to 500 PSI
• Electronic controllers, relays and converters can be provided
Liquid Level Switchesand Sensors
© Copyright Madison Company – 5/08 LL-1
Madison Company(203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • E-mail: [email protected]
Madison EuropePhone + 31 (0) 548 659 034 • Fax + 31 (0) 548 659 010 • E-mail: [email protected]
www.madisonco.com
LL
Full-Size Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
With SLOSH
SHIELD #
MS5000
MS4400
MS8010
MS8020
FITTING
1/8" NPT
1/8" NPT
1/8" NPT
1/8" NPT
FLOAT
SG
0.70
0.45
0.80
0.80
MAX
PSIG
300
150
100
100
MAX TEMP
(CELSIUS)
200°
105°
105°
105°
STEM
MATL
316SS
316SS
316SS
316SS
FLOAT
MATL
316SS
Buna-N
PP†
PP†
DWG
NO.
5
6
6a
6
NOMINAL
VA
30
30
30
30
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C,D
A,B,C
A,B,C
A,B,C,D
Miniature Switches
With SLOSH
SHIELD #
–
–
–
–
MS5010
–
FLOAT
SG
0.60
0.60
0.60
0.70
0.70
0.50
MAX
PSIG
300
300
300
100
300
50
MAX TEMP
(CELSIUS)
200°
200°
200°
200°
200°
150°
STEM
MATL
316SS
316SS
316SS
316SS
316SS
316SS
FLOAT
MATL
316SS
316SS
316SS
316SS
316SS
304SS
DWG
NO.
11
13
12
14
15
42
NOMINAL
VA
30
30
30
30
30
30
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24”
22 AWG Halar Cable
APPROVALS
A,B,C,D,E
A,B,C,D,E
A,B,C,D,E,I
A,C
A,B,C,D
C
FLOAT
SG
0.60
0.60
0.60
0.60
0.60
0.60
0.55
MAX
PSIG
50
50
50
50
50
50
300
MAX TEMP
(CELSIUS)
200°
200°
200°
200°
200°
200°
250°
STEM
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
FLOAT
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
DWG
NO.
16
17
18
16
16
16
14
NOMINAL
VA
30
30
30
30
30
30
60
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
18 AWG TFE 24"
OUTER
THREAD
1/2-13 Bulkhead
1/2 NPT
1/8 NPT
1/2-13 Bulkhead
1/2 NPT
1/8 NPT
5/8-11 Thread
APPROVALS
C
C
C
C
C
C
C
Side-Mounted Switches
MODEL
M5000
M4400
M8010
M8020
MODEL
M5900 b
M5910 b
M5920 b
M5970
M5010
M4214
MODEL
M3827-1
M3827-2
M3827-3
M3827-1NO
M3827-2NO
M3827-3NO
M4249
MODEL
NO.
M5600***
M5600-SPDT
M5601
M5917
M4600
M4600-SPDT
M4601
M8600
M8600-SPDT
M8601
M5600-PR
MSB5600
M3842
With SLOSH
SHIELD #
MS5600
MS5600-SPDT
MS5601
MS5917
MS4600
MS4600-SPDT
MS4601
MS8600
MS8600-SPDT
MS8601
MS5600-PR
–
–
DWG
NO.
1
1
1
1
2
2
2
2
2
2
3
4
4
FLOAT
MATL
316SS
316SS
316SS
316SS
Buna-N
Buna-N
Buna-N
PP†
PP†
PP†
316SS
316SS
316SS
STEM
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
MAX TEMP
(CELSIUS)
200°
200°
200°
250°
105°
105°
105°
105°
105°
105°
200°
110°
90°
MAX
PSIG
200
200
200
200
150
150
150
100
100
100
500
85
30
FLOAT
SG
0.55
0.55
0.55
0.55
0.45
0.45
0.45
0.75
0.75
0.75
0.70
0.55
0.64
NOMINAL
VA
60
25a
100
60
60
25a
100
60
25a
100
100
60
25a
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
18 ga. UL/CSA appr.
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
Teflon Cable 6 ft.
18 AWG Neoprene Cable 10 ft.
FITTING
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
–
–
APPROVALS
A,B,C,D,E,I
A,B,C,D,I
A,B,C,D
A,B,C,D
A,B,C
A,B,C
A,B,C
A,B,C,D
A,B,C,D
A,B,C,D
C,D,I
C, I
C
**
**
**
M Series Stainless Steel Liquid Level Switches
All specifications are subject to change without notice.
PP=Polypropylene † Also available in Polysulfone (consult factory) # Approval “D” does not apply to units with Slosh Shieldsa SPDT switch operation b Available with extended stem length, see drawing No. 19. Consult factory for appropriate model number.** Refer to Approvals pages in Reference Section. Individual product explosion-proof (E) approvals vary. Consult factory for current product listings.*** Also available with a Thermocouple or RTD
LL-2 © Copyright Madison Company – 4/09
**
LL
3/8-24 THD
2.96"(75.1)
1"(25.4)
1.13"(28.7) max.
1.61"(40.8)
BulkheadMounting
0.34”(8.6)min.
0.75” (19.1) HEX
3.19” (81.0) max.
1.06” (26.9) max.
25˚ max.
(1.80”)
(0.93”)
SS Washer
1/2-13 HEX Nut
1/2-13 UNC Thread
Gasket24 ± 1
4.60" max.(116.8)
1/2-14 NPT
1/2-14 NPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
4.60" max.(116.8)
1/2-14 NPT
1-11.5 NPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
4.60" max.(116.8)
1/4-18 NPT
1/2-14 NPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
DWGNo. 15
DWG No. 13
DWG No. 12
DWG No. 11
5.12" (130.05)
6.25" (158.75) max.
3.50"(88.90)
1/2-13THD
1/2" NPT
1/8" NPT
5.77" (146.56)~
5.77" (146.56)~
5
DWGNo. 16
DWGNo. 17
DWG No. 18
DWGNo. 14
1/4" NPT
2.13" (54.1) dia. max.
3.38"(85.8)
2"(50.8)
2.63"(66.8)
1.50" (38.1) dia. max. (Polypro.)1.25" (31.75) dia. max. (Buna-N)
1/4" NPT
3.38"(85.8)
2"(50.8)
2.63"(66.8)
1/4" NPT
2.05" (52.0) dia. max.
2.63"(66.8)
3.38"(85.8)
Mounting bytwo 0.281"(7.1) dia.
holes
2.50"(63.5)
1.75"(44.4)
3.89"(98.8)
Actuationlevel 1.37"(34.7)
DWGNo. 1
1/8" NPT
2.25"(57.1)
1.19"(30.2)
1.63"(41.4)
1.13"(28.7)max.
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
DWGNo. 3
DWGNo. 2
DWGNo. 4
DWGNo. 6
DWGNo. 5
2" dia. max.(50.8 mm)
1/2" NPTINNER THREAD
1/2" NPTOUTER THREAD
“X”SEE TABLE
FOR LENGTH
“Y”SEE TABLE
FOR LENGTH
STEMLENGTH
(0.10")
(1.22" max.)
(1.15" max.)
FITTING
APPROXIMATE ACTUATION LEVEL
1.50" dia. max.(38.1 mm)
1.90" dia. max.(48.2 mm)
1.90" dia. max.(48.2 mm)
2.38" dia. max.(60.4 mm)
Cutaway Showing Slosh Shield Operation Cutaway Showing Slosh Shield Operation
CutawayShowing Slosh ShieldOperation
DWG No. 19
4.63” (117.6) max.
1.30” (33.0) max.
0.40” (10.2)approx.operationpoint
1.50”(33.6)max.
“H” Grommet
30˚ max.
WasherHex Nut
72 ± 2
5/8-11 UNCThreads,
1.25” (31.8) long
0.94”(23.9)Hex
0.50” (12.7)Flats
ø 2.05”(52.1) max.
DWG No. 42
Vertical Switches
Side-Mounted Switches
M Series Stainless Steel Liquid Level Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 8/06 LL-3
3/8-24 THD
2.96"(75.1)
1"(25.4)
1.61"(40.8)
BulkheadMounting
1"(25.4)
DWGNo. 6a
All specifications are subject to change without notice.
Cutaway Showing Slosh Shield Operation Cutaway Showing Slosh Shield Operation
STEM LENGTH “X” DIMENSION REF. “Y” DIMENSION MAX.STANDARD 0.81” 4.60”4-INCH 2.59” 6.42”6-INCH 4.61” 8.42”8-INCH 6.61” 10.42”
LL
Full-Size Switches
Miniature Switches
MODEL
NO.
M8800
M8800-SPDT
M8801
M8800-PR
M7800a
M7800-SPDTa
M7801a
M8060-PR
MSB7800a
MSB8800
With SLOSH
SHIELD #
MS8800
MS8800-SPDT
MS8801
MS8800-PR
MS7800a
MS7800-SPDTa
MS7801 a
MS8060-PR
–
–
DWG
NO.
28
28
28
28
28
28
28
28
29
29
FLOAT
MATL
PP†
PP†
PP†
PP†
Buna-N†
Buna-N†
Buna-N†
PP†
Buna-N†
PP†
STEM
MATL
PP†
PP†
PP†
PP†
PBT†
PBT†
PBT†
CPVC†
PBT†
PP†
MAX TEMP
(CELSIUS)
105°
105°
105°
105°
105°
105°
105°
105°
105°
105°
MAX
PSIG
100
100
100
100
150
150
150
100
150
100
FLOAT
SG
0.75
0.75
0.75
0.75
0.45
0.45
0.45
0.75
0.45
0.75
NOMINAL
VA
60
25b
100
100
60
25b
100
100
60
60
LEAD
WIRES
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. MTW 24"
Nylon Cable 6 ft.
PP Cable 6 ft.
FITTING
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
–
–
APPROVALS
A,B,C,D,I
A,B,C,D
A,B,C,D
C,D
A,B,C
A,B,C
A,B,C
C
C
C
DWG
NO.
30
30
30
30
FLOAT
MATL
PP†
Buna-N†
Buna-N†
Kynar†
STEM
MATL
PP†
PP†
PBT†
Kynar†
MAX TEMP
(CELSIUS)
105°
105°
105°
105°
MAX
PSIG
100
150
150
15
FLOAT
SG
0.80
0.45
0.45
0.85
NOMINAL
VA
30
30
30
30
LEAD
WIRES
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
FITTING
1/8" NPT
1/8" NPT
1/8" NPT
1/8" NPT
APPROVALS
A,B,C,D
A,B,C
A,B,C
A,B,C,D
MODEL
M8000***
M4008
M7000a
M9000
With SLOSH
SHIELD #
MS8000
MS4008
MS7000a
MS9000
Side-Mounted SwitchesMODEL
NO.
M8700
M8725
M8740
M8750
M8790
M8790-14/4184
M7700a
M7725a
M7740a
M7750a
M7790a
M9700
With SLOSH
SHIELD #
M8705
MS8725
–
M8755
–
–
M7705 a
MS7725 a
–
M7755 a
–
M9705
DWG
NO.
32
33
34
35
36
36a
32
33
34
35
36
32
FLOAT
MATL
PP†
PP†
PP†
PP†
PP†
PP†
PBT†
PBT†
PBT†
PBT†
PBT†
Kynar†
STEM
MATL
PP†
PP†
PP†
PP†
PP†
PP†
PBT†
PBT†
PBT†
PBT†
PBT†
Kynar†
MAX TEMP
(CELSIUS)
105°
105°
105°
105°
105°
105°
130°
130°
130°
130°
130°
105°
MAX
PSIG
100
100
100
100
100
100
100
100
100
100
100
100
FLOAT
SG
0.60
0.60
0.60
0.60
0.60
0.60
0.70
0.70
0.70
0.70
0.70
0.93
NOMINAL
VA
30
30
30
30
30
30
30
30
30
30
30
30
LEAD
WIRES
22 ga. MTW 24"
1/4" Spade Terminals
22 ga. Teflon 24"
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. Teflon 24"
1/4" Spade Terminals
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C,D
A,B,C,D
A,B,C ,D
A,B,C,D
A,B,C,D
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C,D
**
**
**
M Series Plastic Liquid Level Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.LL-4 © Copyright Madison Company – 6/08
PP=Polypropylene † Also available in Polysulfone (consult factory) # Approval “D” does not apply to units with Slosh Shields.a Not for use in hot water at temperatures above 65oC b SPDT switch operation** Refer to Approvals pages in Reference Section *** Also available with a Thermocouple or RTD
LL
† Also available in Polysulfone (consult factory) PP=Polypropylene ** Refer to Approvals pages in Reference Section
Subminiature SwitchesMAX TEMP
(CELSIUS)
105°
105°
105°
105°
105°
105°
105°
105°
105°
FLOAT
SG
0.70
0.70
0.70
0.70
0.85
0.70
0.70
0.70
0.70
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
24 ga. Teflon 24"
24 ga. Teflon 24"
With TEMP.
SENSOR
–
–
–
–
–
Type J
Type K
–
–
1.50" (38.1) dia. max. (Polypro.)1.25" (31.75) dia. max. (Buna-N)
1/4" NPT
3.38"(85.8)
2"(50.8)
2.63"(66.8)
DWG No. 28
2" dia. max.(50.8 mm)
Cutaway Showing Slosh Shield Operation
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
DWG No. 30
1.50" dia. max.(38.1 mm)
Cutaway Showing Slosh Shield Operation
Mounting bytwo 0.281"(7.1) dia.
holes
2.50"(63.5)
1.75"(44.4)
3.89"(98.8)
Actuationlevel 1.37"(34.7)
DWG No. 29
1.85"(47)
1.25"(31.7)
.58"(14.7)
"O"Ring
3/8-16 THD
.63"(16.0)
DWG No. 31a
1/2" NPT 2.75" (69.8) max.
DWG No. 32
2.75" (69.8) max.1/2" NPT
DWG No. 33
4.30" (109.2)
3.31" (84.0) 7/8-14 THD
3/4-16 THD
DWG No. 34
2.75" (69.8) max.1/2" NPT
DWG No. 35
4.02" (102.1)
2.84" (72.1)5/8-11 THD
DWG No. 36
24.0 ± 1.0Wire Leads: 22 AWG MTW
Washer
Compression Gasket
ø.88” (22.4) Requires ø.91 mounting hole
5/8-11 UNC Nut
3.31” (84.1) max.
0.63” (16.0) min.
0.56” (14.2) min.
0.60” (15.2) min.
DWG No. 36a
2.84" (73.1 mm) max.
1" NPT
Cutaway Showing Slosh Shield Operation
**
M Series Plastic Liquid Level Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/10 LL-5
DWG No. 31b
1.68"(42.6)
1.25"(31.7)
.58"(14.7)
.63"(16.0)
1/8" NPT
DWG No. 31c
"O" Ring
1.85"(47)
1.24"(31.5)
24” ± 1.0”22 AWG TEFLONLEADS
Hex Nut3/8-16 UNC 2B9/16 acrossFlats
"O" Ring
.44"(11.2)
MØ.78"(19.8)
All specifications are subject to change without notice.
STEM
MATL
PP†
PP†
PP†
PP†
PP†
PP†
PP†
316SS
316SS
1/8" NPT
2 x 24” LEAD WIRES24 AWG TEFLONINSULATED
APPROX.ACTIVATIONLEVEL
7/16 HEX
.75"(19.1)
.27"(6.9) 1.44"
(36.6)
ø.78"(19.8)
DWG No. 39a
3/8 x 24 THREAD.75” (19.1) LONG
2 x 24” LEAD WIRES24 AWG TEFLONINSULATED
APPROX.ACTIVATIONLEVEL
.56” HEX(14.2)
.50"(12.7) .95"
(24.1)
MOUNTING NUT(SUPPLIED)
ø.78"(19.8)
1.70"(43.2)
DWG No. 39b
With SLOSH
SHIELD
M3326
M3326-NO
M3326-NPT
M3326-NPT-NO
M3326-SM
MT3920-1
MT3920-2
M4035
M4035-B
DWG
NO.
31a
31a
31b
31b
31c
31a
31a
39a
39b
FLOAT
MATL
PP†
PP†
PP†
PP†
PP†
PP†
PP†
PP†
PP†
MAX
PSIG
50
50
50
50
50
50
50
100
100
NOMINAL
VA
15
15
15
15
15
15
15
15
15
FITTING
3/8-16
3/8-16
1/8" NPT
1/8" NPT
3/8-16
3/8-16
3/8-16
1/8" NPT
3/8-24
APPROVALS
A,B,C
A,B,C
C
C
A,C
A,B,C
A,B,C
C
C
LL
3/8-24 THD
2.96"(75.1)
1"(25.4) max.
1.61"(40.8)
BulkheadMounting
Full-Size Switches
With SLOSH
SHIELD
MS4500
MS5040
MS8040
FITTING
1/8" NPT
1/8" NPT
1/8" NPT
FLOAT
SG
0.45
0.70
0.80
MAX
PSIG
150
300
100
MAX TEMP
(CELSIUS)
105°
200°
105°
STEM
MATL
Brass
Brass
Brass
FLOAT
MATL
Buna-N
316SS
PP†
DWG
NO.
22
22
22
NOMINAL
VA
30
30
30
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C
A,B,C
A,B,C
Miniature Switches
With SLOSH
SHIELD
MS4010
FLOAT
SG
0.45
MAX
PSIG
100
MAX TEMP
(CELSIUS)
105°
STEM
MATL
Brass
FLOAT
MATL
Buna-N
DWG
NO.
23
NOMINAL
VA
30
LEAD
WIRES
22 ga. Teflon 24"
APPROVALS
A,B,C
Side-Mounted Switches
MODEL
M4500
M5040
M8040
MODEL
M4010
MODEL
NO.
M4300
M4300-SPDT
M4301
M5400
M5400-SPDT
M5401
M8400
M8400-SPDT
M8401
With SLOSH
SHIELD
MS4300
MS4300-SPDT
MS4301
MS5400
MS5400-SPDT
MS5401
MS8400
MS8400-SPDT
MS8401
DWG
NO.
21
21
21
21
21
21
21
21
21
FLOAT
MATL
Buna-N
Buna-N
Buna-N
316SS
316SS
316SS
PP†
PP†
PP†
STEM
MATL
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
MAX TEMP
(CELSIUS)
105°
105°
105°
200°
200°
200°
105°
105°
105°
MAX
PSIG
150
150
150
200
200
200
100
100
100
FLOAT
SG
0.45
0.45
0.45
0.55
0.55
0.55
0.75
0.75
0.75
NOMINAL
VA
60
25*
100
60
25*
100
60
25*
100
LEAD
WIRES
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. MTW 24"
22 ga. Teflon 24"
22 ga. MTW 24"
FITTING
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
APPROVALS
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
A,B,C
1.50" (38.1) dia. max. (Polypro.)1.25" (31.75) dia. max. (Buna-N)
1/4" NPT
3.38"(85.8)
2"(50.8)
2.63"(66.8)
DWG No. 21
2" dia. max.(50.8 mm)
Cutaway Showing Slosh Shield Operation
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
DWG No. 22
1.50" dia. max.(38.1 mm)
Cutaway Showing Slosh Shield Operation
DWG No. 23
Cutaway Showing Slosh Shield Operation
1.50" dia. max.(38.1 mm)
**
**
**
M Series Brass Liquid Level Switches
* SPDT switch operation PP=Polypropylene † Also available in Polysulfone (consult factory) ** Refer to Approvals pages in Reference Section
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.LL-6 © Copyright Madison Company – 1/06
LL
M Series Metric Sizes Liquid Level Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/10 LL-7All specifications are subject to change without notice.
Full-Size SwitchesMODEL
NO.
M3842
M5000-E
M5600-E
MSB5600
MSB7800
MSB8800
With SLOSH
SHIELD
M3782
DWG
NO.
40
4
5
1
4
29
29
FLOAT
MATL
Buna-N*
316SS
316SS
316SS
316SS
Buna-N
PP†
STEM
MATL
Brass
316SS
316SS
316SS
316SS
PBT
PP
MAX TEMP
(CELSIUS)
105°
90°
200°
200°
110°
105°
105°
MAX
PRESSURE
3.4 BAR
2 BAR
20 BAR
13 BAR
5.8 BAR
10 BAR
6 BAR
FLOAT
SG
0.45
0.64
0.70
0.55
0.55
0.45
0.75
NOMINAL
VA
30
25
30
60
60
60
60
LEAD
WIRES
22 ga. PVC cable 6m
18 AWG Neoprene cable 3m
22 ga. Teflon 500mm
22 ga. Teflon 500mm
Teflon cable 1.8m
Nylon cable 1.8m
PP cable 1.8m
FITTING
G 1/8 A
G 1/4 A
APPROVALS
C
C
A,B,C,D
A,B,C,D
C, I
C
C
* Slosh Shield is PBT PP=Polypropylene † Also available in Polysulfone (consult factory) # Consult factory for specific size** Refer to Approvals pages in Reference Section. Individual product explosion-proof (E) approvals vary. Consult factory for current product listings.
Side-Mounted SwitchesWith SLOSH
SHIELD FITTING
Bulkhead #
Bulkhead #
Bulkhead #
Bulkhead
Available Mountings and OptionsM5900: 1-11.5 NPT x 1/2-14 NPT M5910-E: Fittings/Flanges: 1/2-14 BSPT x 1/4-19 BSPT M5920-E: 1/2-14 BSPT x 1/2-14 BSPT M5970: 1/2-13 Bulkhead
Subminiature SwitchesMODEL
NO.
M3326
M3326-NO
With SLOSH
SHIELD
DWG
NO.
31a
31a
FLOAT
MATL
PP†
PP†
STEM
MATL
PP
PP
MAX TEMP
(CELSIUS)
105°
105°
MAX
PRESSURE
3 BAR
3 BAR
FLOAT
SG
0.70
0.70
NOMINAL
VA
15
15
LEAD
WIRES
22 ga. Teflon 500mm
22 ga. Teflon 500mm
FITTING
3/8-16
3/8-16
APPROVALS
A,B,C
A,B,C
Miniature SwitchesMODEL
NO.
M7000B
M8000B
M8010
With SLOSH
SHIELD
MS8000B
DWG
NO.
30
30
6a
FLOAT
MATL
Buna-N
PP†
PP†
STEM
MATL
PBT
PP
316SS
MAX TEMP
(CELSIUS)
105°
105°
105°
MAX
PRESSURE
10 BAR
6 BAR
6 BAR
FLOAT
SG
0.45
0.80
0.80
NOMINAL
VA
30
30
30
LEAD
WIRES
22 ga. Teflon 500mm
22 ga. MTW 500mm
22 ga. Teflon 500mm
FITTING
Bulkhead
Bulkhead
Bulkhead
APPROVALS
A,B,C
A,B,C,D
C
Multi-Level SwitchesMODEL
NO.
M5002-E
M5602-E
With SLOSH
SHIELD
DWG
NO.
7
7
FLOAT
MATL
316SS
316SS
STEM
MATL
316SS
316SS
MAX TEMP
(CELSIUS)
200°
200°
MAX
PRESSURE
20 BAR
13 BAR
FLOAT
SG
0.70
0.55
NOMINAL
VA
30
60
LEAD
WIRES
22 ga. Teflon 500mm
22 ga. Teflon 500mm
FITTING APPROVALS
A,B,C,D
A,B,C,D
Available Mountings and OptionsM5002-E Fittings/Flanges: Outside Mount Flange or pipe plug; Inside mount (specify thread size) or bulkheadM5602-E Fittings/Flanges: Outside Mount Flange or pipe plug; Inside mount (specify thread size) or bulkhead
**
**
**
**
**
DWG
NO.
16
–
–
11
13
12
14
42
34
35
34
36
36a
36
41
23
MODEL
NO.
M3827-1
M3827-1NO
M4003
M5900
M5910-E
M5920-E
M5970
M4214
M8740
M8750
M7740
M8790
M8790-14/4184
M7790
M3769
M4010
FLOAT
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
304SS
PP†
PP†
PBT
PP†
PP†
PBT
PP†
Buna-N
STEM
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
PP†
PP†
PBT
PP†
PP†
PBT
PVC
Brass
MAX TEMP
(CELSIUS)
200°
200°
200°
200°
200°
200°
200°
150°
105°
105°
150°
105°
105°
150°
105°
105°
MAX
PRESSURE
3 BAR
3 BAR
20 BAR
20 BAR
20 BAR
20 BAR
6 BAR
3.45 BAR
6 BAR
6 BAR
6 BAR
6 BAR
6 BAR
6 BAR
1 BAR
6 BAR
FLOAT
SG
0.60
0.60
0.60
0.60
0.60
0.60
0.70
0.50
0.60
0.60
0.70
0.60
0.60
0.70
0.45
NOMINAL
VA
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
LEAD
WIRES
22 ga. Teflon 600mm
23 ga. Teflon 600mm
22 ga. PVC 2m
22 ga. Teflon 600mm
22 ga. Teflon 500mm
22 ga. Teflon 500mm
22 ga. Teflon 600mm
22 AWG Halar Cable
22 ga. Teflon 600mm
22 ga. MTW 600mm
22 ga. Teflon 600mm
22 ga. MTW 600mm
22 ga. MTW 600mm
22 ga. Teflon 600mm
22 ga. Halar Cbl. 3m
22 ga. Teflon 600mm
APPROVALS
C
C
C
A,B,C,D,E
A,B,C,D,E
A,B,C,D,E,I
A,C
C
A,B,C,D
A,B,C,D
A,B,C
A,B,C,D
A,B,C
A,B,C
C
A,B,C
LL
M Series Metric Sizes Liquid Level Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.LL-8 © Copyright Madison Company – 10/07
G 1/4 A
2.13" (54.1) dia. max.
3.38"(85.8)
2"(50.8)
2.63"(66.8)
DWGNo. 1
2.38" dia. max.(60.4 mm)
Cutaway Showing Slosh Shield Operation
Mounting bytwo 0.281"(7.1) dia.
holes
2.50"(63.5)
1.75"(44.4)
3.89"(98.8)
Actuationlevel 1.37"(34.7)
DWGNo. 4
G 1/8 A
2.25"(57.1)
1.19"(30.2)
1.63"(41.4)
1.13"(28.7)max.
DWGNo. 5
1.90" dia. max.(48.2 mm)
Cutaway Showing Slosh Shield Operation
3/8-24 THD
2.96"(75.1)
1"(25.4)
1.61"(40.8)
BulkheadMounting
1"(25.4) DWG
No. 6a
DWG No. 7
4.60" max.(116.8)
1/2 BSPT
1/2 BSPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
4.60" max.(116.8)
1/2-14 NPT
1-11.5 NPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
4.60" max.(116.8)
1/4 BSPT
1/2 BSPT
WIRE LEADS
0.81" min.(20.6)
1.22" max.(31.0)
1.15" max.(29.2)
FITTINGCENTERLINE
.10"(2.5)
APPROXIMATEACTUATION LEVEL
DWG No. 13
DWG No. 12
DWG No. 11
0.34”(8.6)min.
0.75” (19.1) HEX
3.19” (81.0) max.
1.06” (26.9) max.
25˚ max.
(1.80”)
(0.93”)
SS Washer
1/2-13 HEX Nut
1/2-13 UNC Thread
Gasket24 ± 1
5.12" (130.05)
6.25" (158.75) max.
3.50"(88.90)
1/2-13THD
1/2" NPT
1/8" NPT
5.77" (146.56)~
5.77" (146.56)~
5
DWGNo. 16
DWGNo. 14
Mounting bytwo 0.281"(7.1) dia.
holes
2.50"(63.5)
1.75"(44.4)
3.89"(98.8)
Actuationlevel 1.37"(34.7)
DWGNo. 29
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
DWG No. 301.50" dia. max.
(38.1 mm)
Cutaway Showing Slosh Shield Operation
1.85"(47)
1.25"(31.7)
.58"(14.7)
"O"Ring
3/8-16 THD
.63"(16.0)
DWG No. 31a4.30" (109.2)
3.31" (84.0) 7/8-14 THD
3/4-16 THD
DWG No. 34
2.75" (69.8) max.1/2" NPT
DWG No. 35
4.02" (102.1)
2.84" (72.1)5/8-11 THD
DWG No. 36
3/8-24 THD
2.96"(75.1)
1"(25.4) max.
1.61"(40.8)
BulkheadMounting
DWGNo. 23
Cutaway Showing Slosh Shield Operation
1.50" dia. max.(38.1 mm)
Wire Leads
4.06"(103.1)
ø1.44"(36.6)
DWG No. 40
3.00"(76.2)
1.50"(38.1)
0.375" (9.53)
10' Cable Leads
Switch Housing
Float
Pivot Pin
Attach String Here to Pull Through Tank
.75" REF (19.1)
DWG No. 41
2.13" dia. max.(54.1)
24.0 ± 1.0Wire Leads: 22 AWG MTW
Washer
Compression Gasket
ø.88” (22.4) Requires ø.91 mounting hole
5/8-11 UNC Nut
3.31” (84.1) max.
0.63” (16.0) min.
0.56” (14.2) min.
0.60” (15.2) min.
DWG No. 36a
4.63” (117.6) max.
1.30” (33.0) max.
0.40” (10.2)approx.operationpoint
1.50”(33.6)max.
“H” Grommet
30˚ max.
WasherHex Nut
72 ± 2
5/8-11 UNCThreads,
1.25” (31.8) long
0.94”(23.9)Hex
0.50” (12.7)Flats
ø 2.05”(52.1) max.
DWG No. 42
LL
M SeriesSingle-Point Liquid Level Switches
Engineered single-level switches
Madison Company offers a complete line of Standard andConfigured (slightly modified Standard designs) models.These products continue to meet the needs ofapplications in many markets, at competitive prices. Inaddition, Madison Company offers the capability to designspecific liquid level switches for OEM applications thatrequire unique considerations in materials, configurationsand system interfacing.
Engineered designs incorporate over 50 years ofexperience in liquid level switch applications in a varietyof environments and installation configurations. Highreliability of the magnetic reed switch technology assuresrepeatability at an economical price. Our designexperience and flexible manufacturing techniques alsooffer customers many value-added design and assemblyoptions to reduce their product cost.
Features
• Single-point • Magnetic reed switch technology
• High reliability • Wide selection of available materials
• Three basic sizes: full, miniature and subminiature
• Direct interface to controllers available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 3/11 LL-9
Each style switch is equipped with a means to identify which type of operation to which the switch is set.
Vertical: NO/NC operation is indicated by the position of the witness mark (stainless steel models) or magnets
(plastic models). NO is indicated by circle up (stainless steel) or magnets down plastic); NC is indicated by circledown (stainless steel) or magnets up (plastic).
Horizontal: NO/NC operation is indicated by the direction of the arrow on the hex. NO is indicated by arrow up;
NC is indicated by arrow down. An ohmmeter or continuity meter can be used to verify the switch setting andoperation. Simply connect the meter to the leads and, with the float hanging down away from the fitting, measure theswitch. If the meter reads a short, then the switch is normally closed and will open on rise.
All switches are shipped in the Normally Closed (NC) position, unless otherwise specified. To change the contactoperation, simply remove the retaining ring and float and reverse the float on the stem. The only exception to this isthe subminiature switch (M3326/M3326-NO), for which operation must be specified when ordered, since the float isnot reversible on this switch.
LL
Material Selection Guide
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-10 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
The first consideration is the type of liquid, temperature and pressure to which the switch will be subjected. Madisonmanufactures liquid level switches in various styles, in avariety of materials, to cover a broad range of conditions.Following are some basic recommendations for selectingthe proper liquid level switch material for your application.
Material
316 Stainless Steel
PolypropylenePolysulfone
Brass & Buna-NPBT & Buna-N
KynarPTFE
Application
For high-temperature (to 300˚C), high-pressure (to 300 PSIG) andcorrosive conditions. Commonly used in food processing, medical,heating and cooling equipment.
For acidic conditions, such as found in electroplating and metalcleaning. Another choice for lower-temperature (to 105˚C) foodprocessing applications (Madison Company uses only polypropylenethat is FDA-approved for food contact). Also a good choice forgeneral-purpose applications in commercial or consumer appliancesand equipment. Available in white and other colors.
The selection for petroleum-based liquids, such as lubricating oils,gasoline and diesel fuels. Widely used in storage tanks of vehicles,generators, transmissions and hydraulic systems. Other uses are inlubrication, recovery, refining and fuel processing equipment. Please note: PBT is not suitable for use in temperatures above 130˚C.
Chemical- and solvent-resistant properties make this material aproblem solver for many applications. Its high-purity nature is idealfor food handling and sensitive laboratory or test equipment.
Once a suitable material has been selected, the type of switch and configuration are the nextconsiderations. Madison Company stocks a full line of standard products that can meet therequirements of many applications. For specific designs, Madison can custom-build, to order,switches with an infinite number of variations and options. Please utilize our M & MT Series single-level specification sheet which, when completed, will allow our engineering department tobetter meet your needs.
COMPONENT
See Approvals pages in Reference Section
LL
MT SeriesCombinationLevel/Temperature Sensors
Features
• Full size range of level switches available
• Broad selection of materials
• Dual-condition monitoring
• Standard or custom designs
• Electronic interfaces available
• Selected models carry industry-specific approvals (UL, NSF, CE)
• All technologies highly reliable
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 LL-11
Switches shown above arerepresentative of our combination
level/temperature sensor capabilities.(Models MT3920-1, MT5600-1
and MT8000-1)
Madison Company offers many of its liquid level switchproducts with temperature sensing capabilities. Theincorporation of either thermocouples, RTD sensors,thermistors or bimetal switches can offer the user theability to determine level and temperature in the vesseland save the cost of having dual mounting considerations.Linked with Madison’s cable assemblies and controllers,combination sensors can provide a readout of theenvironmental conditions, as well as the capability to turnassociated equipment on and off.
The temperature limitations are dependent on thematerials selected for the level switch itself. As anexample, the subminiature Model MT3920-1 is apolypropylene level switch with a Type J thermocouple.The thermocouple temperature range is -40˚C to 250˚C (-40˚F to 482˚F), while the polypropylene is rated to105˚C (221˚F). Another example is a single-point 316stainless steel liquid level switch engineered for use in a300˚C (572˚F) environment. Other considerations thatMadison Company makes are the position of the sensors,time response and signal conditioning. Time responsetesting on selected MT configurations has shown a typicalresponse time to be 20 to 25 seconds.
LL
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-12 © Copyright Madison Company – 10/10
MT Series Specifications
All specifications are subject to change without notice.
Nearly all of Madison’s Single-Point, Multi-Point and Continuous Level Switches and Sensors areavailable as MT Series Combination Level/Temperature Sensors. Consult factory for details.
* SPDT reed switch operation NC Creep-action bimetal switch, open on rise NO Creep-action bimetal switch, close on rise† Also available in Polysulfone (consult factory) PP=Polypropylene** Refer to Approvals pages in Reference Section
Note regarding Bimetal switches: Snap action and creep action may be available in other temperature ranges. Complete our Specification WorkSheet with your specific application requirements and submit it for a quote.
Standard Stainless Steel MT Series SwitchesDWG
NO.
5
1
1
1
1
1
1
1
MAX TEMP
(CELSIUS)
200°
200°
200°
200°
200°
200°
200°
200°
MAX
PSIG
300
200
200
200
200
200
200
200
FLOAT
SG
0.70
0.55
0.55
0.55
0.55
0.55
0.55
0.55
NOMINAL
VA
30
60
60
60
25*
25*
60
60
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
FITTING
1/8" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
1/4" NPT
APPROVALS
C,D
A,C,D
A,C,D
A,C,D
A,C,D
A,C,D
A,C,D
A,C,D
MODEL
MT5000-HT-J
MT5600
MT5600-1
MT5600-2
MT5600-3*
MT5600-4*
MT5600-5-85C
MT5600-5-85C-NO
With TEMP.
SENSOR
Type J
Type J
Type K
100 ohm RTD
Type J
Type K
BimetalNC
BimetalNO
**FLOAT
MATL.
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
STEM
MATL.
316SS
316SS
316SS
316SS
316SS
316SS
316SS
316SS
Standard Plastic MT Series SwitchesDWG
NO.
31a
31a
30
30
30
30
MAX TEMP
(CELSIUS)
105°
105°
105°
105°
105°
105°
MAX
PSIG
50
50
100
100
100
100
FLOAT
SG
0.70
0.70
0.80
0.80
0.80
0.80
NOMINAL
VA
15
15
30
30
30
15
LEAD
WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. MTW 24"
22 ga. MTW 24"
FITTING
3/8-16
3/8-16
1/8" NPT
1/8" NPT
1/8" NPT
1/8" NPT
APPROVALS
A,C
A,C
A,C,D
A,C,D
A,C,D
C,D
MODEL
MT3920-1
MT3920-2
MT8000
MT8000-1
MT8000-2
MT8000-4-66C
With TEMP.
SENSOR
Type J
Type K
Type J
Type K
100 ohm RTD
BimetalNO
**FLOAT
MATL.
PP†
PP†
PP†
PP†
PP†
PP†
STEM
MATL.
PP†
PP†
PP†
PP†
PP†
PP†
1/4" NPT
2.13" (54.1) dia. max.
3.38"(85.8)
2"(50.8)
2.63"(66.8)
DWG No. 1
1/8" NPT
2.25"(57.1)
1.19"(30.2)
1.63"(41.4)
1.13"(28.7)max.
DWG No. 5
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
DWG No. 30
1.85"(47)
1.25"(31.7)
.58"(14.7)
"O"Ring
3/8-16 THD
.63"(16.0)
DWG No. 31a
LL
M SeriesHVAC SeriesCondensate Level Switches
Features
• Highly reliable
• Affordable off-the-shelf design
• Easy installation
• Custom features available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 LL-13
Madison Company offers a standard family ofwater-activated level switches designed forcondensate return systems in HVAC and HVACRsystems. These condensate level float switchescan be used for the return of hot condensate in aboiler system, in an air conditioning condensateline, or to give a signal to a pump or compressorcontrol when water is detected in the drain pan.
The M8000-C float switch is designed for either apress fit into a standard 3/4” schedule 40 PVC pipetee allowing for future clean out, or glued in placeusing standard PVC pipe cement. This verticallymounted switch will provide an excellent levelsignal at up to a 30° angle and incorporates a venthole for line air to escape.
The M8000, also a vertically mounted switch,requires a mounting hole to accommodate a 1/8”NPT fitting. The M8700-C is a horizontally mountedfloat switch for use where side mounting ispreferred, such as in the side of a pan or reservoir.
These switches can also be used in compressed air condensate drain lines that are normally found on intercoolers, after coolers, dryers, drip legs and receiver tanks. They are cost-effectivesolutions when compared to electric solenoidvalve methods.
M8000
M8000-C
M8700-C
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-14 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
* With vent hole plugged
INSTALLATION NOTE: As with any condensate line, contamination from water content and debris could inhibit proper floatoperation. Occasional cleaning can be accomplished by wiping with a soft cloth. Flush line with bleach and a descaling solution if water conditions require such treatment.
HVAC Series
Material
Maximum Pressure
Maximum Temperature
Float Specific Gravity
Fitting
Lead Wires
Nominal VA
Approvals
M8700-C
Polypropylene
100 PSIG
105˚C (221˚F)
0.60
1/2” NPT or 3/4” NPT
22 ga. MTW 24”
30
UL, CSA, CE, NSF
M8000
Polypropylene
100 PSIG
105˚C (221˚F)
0.80
1/8” NPT
22 ga. MTW 24”
30
UL, CSA, CE, NSF
M8000-C
Polypropylene/PVC
50 PSIG*
60˚C (140˚F)
0.85
3/4” PVC Pipe
22 ga. MTW 24”
30
UL, CSA, CE
1.99"(50.5)
1.55"(39.4)
ø1.058"(26.9)
ø.875"(22.2)
1.125 1.25"OPERATION POINT
24.0 1.0"
.063"(609.6)
(1.6)
(28.6)
M8000 M8000-C
M8700-C
1/8" NPT
2.25"(57.1)
1.63"(41.4)
1"(25.4)
1"(25.4)
1/2" NPT 2.75" (69.9) max.3/4" NPTLL
M SeriesLevel Switchesfor Harsh Environments
Features
• Magnetic reed switch technology
• High reliability under harsh conditions
• Can incorporate both point level indication and temperature measurement
• Available in single-point and multi-point designs
• Continuous level in standard resolutions of 1”, 5mm or 10mm
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 LL-15
Madison Company offers many of its liquid level switch products with high-temperaturecapabilities. A list of available models is on thereverse side. In addition, engineered designs tomeet specific application needs can be provided.Such designs will deal with harsh environmentssuch as high temperature and pressure and ensure material compatibility.
Using highly reliable magnetic float switchtechnology, units capable of reliable operation attemperatures as high as 300˚C (572˚F) andpressures of up to 1500 PSI (103 BAR) have beendesigned. Such harsh-environment switches canincorporate Madison’s temperature sensors, offeringthe combination of both point level indication andtemperature measurement within the same levelswitch design. This can eliminate costs for multiplemountings during assembly, while providing dual-condition monitoring. Level indication can be single-point, multi-point or continuous level, in one of threestandard resolutions.
Lead wires with overbraiding or shielding andvarious terminations can be designed for extremeconditions, as well as easy interfacing to conditionmonitoring devices.
A selection of engineered level switches
LL
Level Switches for Harsh Environments
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-16 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Engineered designs available to meet application-specific needs. Please consult factory.
StandardModels
M5600M5600-SPDTM5601M5600-PRM5000M5900M5910M5920M5970M5010M3827-1M3827-2M3827-3M3827-1NOM3827-2NOM3827-3NOM5400M5400-SPDTM5401M5040M5602M5002M5402M5042M5600-EM5000-EM5910-EM5920-EM5602-EM5002-EM5917M3627
withSlosh Shield
MS5600MS5600-SPDTMS5601MS5600-PRMS5000
MS5010
MS5400MS5400-SPDTMS5401MS5040
MS5917
Max.Temp.
200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C200˚C250˚C250˚C
Max.Pressure
200 PSIG200 PSIG200 PSIG500 PSIG300 PSIG300 PSIG300 PSIG300 PSIG100 PSIG300 PSIG50 PSIG50 PSIG50 PSIG50 PSIG50 PSIG50 PSIG200 PSIG200 PSIG200 PSIG300 PSIG200 PSIG300 PSIG200 PSIG300 PSIG13 BAR20 BAR20 BAR20 BAR13 BAR20 BAR
200 PSIG300 PSIG
FloatSG
0.550.550.550.700.700.600.600.600.700.700.600.600.600.600.600.600.550.550.550.700.550.700.550.700.550.700.600.600.550.700.550.70
Fitting
1/4” NPT1/4” NPT1/4” NPT1/4” NPT1/8” NPT1” NPT X 1/2” NPT1/2” NPT X 1/4” NPT1/2” NPT X 1/2” NPT1/2-13 Bulkhead3/8-24 Bulkhead1/2-13 Bulkhead1/2” NPT1/8” NPT1/2-13 Bulkhead1/2” NPT1/8” NPT1/4” NPT1/4” NPT1/4” NPT1/8” NPT
G 1/4 AG 1/8 A1/2-14 BSPT X 1/4-19 BSPT1/2-14 BSPT X 1/2-14 BSPT
1/4” NPT1/8” NPT
LL
M SeriesSwitches for Harsh Environments& High-Purity Applications
Features
• All PTFE wetted surfaces
• Chemically inert
• Low particulate generation
• High purity reduces contamination
• Standard and engineered liquid level designs available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 LL-17
Madison Company has a complete line of level switches thatoffer all wetted polytetrafluoroethylene (PTFE) materials.PTFE is a chemically inert material that offers exceptionalperformance when aggressive solvents such as alcohols,esters and ketones, or other corrosive acids and bases, oils,steam and most chemicals, are present in your application.
These M Series switches are ideal for medical,pharmaceutical and food or beverage applications wherehigh-purity contact is essential. Other applications withstringent requirements, such as electronic componentmanufacturing, sterilization systems and those systemsrequiring biosafety performance standards of the liquid levelswitch, will find this Madison material capability suitable.
PTFE’s characteristics are ideal for withstanding extremeoperating temperatures, strenuous chemical environmentsand those applications where highly abrasive-resistantperformance is required.
The switch’s float is designed with an advanced chemicallymodified PTFE. While retaining the exceptional chemicalproperties of the conventional PTFE, superior thermal andmechanical properties have been introduced. This modifiedPTFE has also allowed some designs to be offered withoutthe spring assist that is found in many heavier float designs.
With the highly reliable reed switch technology and thePTFE wetted material, these liquid level switches offerdependability over a long service life.
Representative PTFE switches
LL
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-18 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Material Approvals – CE, FDA Regulation 21 CFR 177.1550, USP Class 6
Standard Models
M9200
M9200-E
M9200-NO
M9200-NO-E
M9500
M9500-E
M9202-XXXX
M9502-XXXX
MaximumTemperature
150˚C (302˚F)
150˚C (302˚F)
150˚C (302˚F)
150˚C (302˚F)
150˚C (302˚F)
150˚C (302˚F)
MaximumPressure*
25 PSIG
25 PSIG
25 PSIG
25 PSIG
40 PSIG
40 PSIG
Fitting
1/8-27 NPT
G 1/8 A
1/8-27 NPT
G 1/8 A
1/4-18 NPT
G 1/4 A
SwitchRating
60-Watt SPST
60-Watt SPST
60-Watt SPST
60-Watt SPST
60-Watt SPST
60-Watt SPST
Float SG
0.69
0.69
0.69
0.69
0.63
0.63
NO – Normally Open; SPST – Single Pole Single Throw
Multi-point switch with M9200 characteristics
Multi-point switch with M9500 characteristics
* Maximum pressure at 21˚C
Lead wires are PTFE jacketed unless otherwise specified.
LL
M Series“Tank Commander” Heavy-DutySide-Mounted Level Switch
Features
• Rugged design
• Field serviceable
• Allows for direct switching
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 LL-19
Madison Company’s M4065 side-mountedliquid level switch has both a rugged designand sufficient electrical switch power toeliminate the need for separate relays inyour current.
As with all Madison side-mount designs, theM4065 “Tank Commander” is intended formounting through a tank’s side wall utilizinga 1-1/2” NPT through hole.
The switch’s electrical ratings (refer to backside of sheet) allow for direct switchingcontrol of a pump’s on/off action. Thiseliminates the need for intermediate relays,along with their associated costs.
The M4065 basic design allows for fielddisassembly and cleaning when used inliquids containing contaminants or causingresidual build-up. This can extend theswitch’s serviceable life with plannedmaintenance.
M4065 heavy-duty side-mounted liquid level switch
LL
M4065 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-20 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Electrical – 20 A @ 125, 250 or 480 VAC10 A @ 125 VAC inductive1 HP @ 125 VAC2 HP @ 250 VAC1/2 A @ 125 VDC1/4 A @ 250 VDC
In-rush current is good for 75 A @ 120-480 VAC and varying currents at DC voltages.
Max. Operating Pressure – 100 PSIG (6.89 bar)
Max. Operating Temperature – 125˚C (257˚F)
Wetted Materials – 304 Stainless Steel, standard
Float Specific Gravity – 0.6
Mounting Box Enclosure – PVC with Viton sealing gasket
Wiring Diagram
NO
NC
Com
Switch type: SPDT Micro switch, screw terminals
4.13”(104.9)
3.13” (79.5)
2.56”(65.0)
1.56”(39.6)
4.75” (120.7)1.13” (28.7)0.69” (17.5)
5.5” (139.7)
1-1/2-11.5 NPT
1.65”(41.9)
LOWEST FLOAT POSITIONSCALE 3/4
HIGHEST FLOAT POSITIONSCALE 3/4
1.66”(42.1)
5.00”(127.0)
2.00”(50.8)
4.50” (114.3)
2.25” (57.2)
LL
M Series“Big Dipper” Heavy-DutyIndustrial Side-Mounted Switch
Features
• Easy mounting to vessel side wall
• Easy control circuit wiring
• Rugged design
• Suitable for high-contamination applications with field cleaning of float by user
• High reliability
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/06 LL-21
Madison Company’s M4190 family of side-mountedliquid level switches features a robust design forheavy industrial tank applications.
Their corrosion-resistant construction, inconjunction with standard SPDT switch operation,provides for simplified wiring of control circuits. The M4190’s standard end thread is a 1/2” NPTstub for easy connection to common junction boxesor conduit.
The base model M4190 features 304 stainless steelconstruction, including the float. The M4190-BUoffers a Buna-N float for hydrocarbon liquids, andthe M4190-HP offers a float rated for 900 PSIoperational performance.
The standard configuration can be modified toaddress specific application requirements. ConsultMadison Company for such needs.
M4190
M4190-BU
M4190-HP
LL
M4190 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-22 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
* Due to the M4190-HP’s float diameter (2”), if access to the inside of the vessel is not available you must use a suitable bushing oradapter for a mounting hole larger than 2”.
“Big Dipper”
Wetted Materials:FloatStemOther
Operating Temperature
Operating Pressure
Switch Rating
Float Specific Gravity
Lead Wires
Mounting
M4190-HP
304SS304SS
Teflon® & Ceramic
150˚C (302˚F)
900 PSI
0.5
*
M4190
304SS304SS
Teflon® & Ceramic
150˚C (302˚F)
150 PSI
~ 0.5
1-11.5 NPT
M4190-BU
Buna-N304SS
Teflon® & Ceramic
105˚C (221˚F)
100 PSI
0.4
1-11.5 NPT
All Models: SPDT, 100 VA; 120 VAC max.
All Models: 22 AWG Teflon® jacket, 24” length standard
VE
4.
5.81” (147.6) max.
ø 1.00”(25.4)
1-11.5 NPTmounting threads
1-3/8 HEX
1/2” NPTconduit connection
22 AWG Teflon-insulated lead wires,24” long
3.45” (87.6)
VE
4.
4.43” (112.5) max.
ø 0.92”(23.4)
VE
4.
3.98” (101.1) max.
ø 2.04”(51.8)
Demountable float
4
M4190
M4190-BU
M4190-HP
M4190 Wiring Diagram
VE
4.
1.70”(43.2)
ø 1.00”(25.4)
4.06” (103.1) max.
B
M4190-SMVertical Mount
VE
BLACK – COMMON
ORANGE – N.O.
RED – N.C.
LL
M SeriesSubminiature Liquid Level Switches
Features
• Subminiature size
• Single or dual point indication
• Vertical or horizontal mounting
• Level and temperature sensing in one device
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/08 LL-23
Madison Company’s line of subminiature liquidlevel switches offers a full range of vertical and horizontal mount configurations in single-point switch designs. In addition, there is a multi-level subminiature switch design offering two switch points within the same subminiaturedesign envelope.
As with all Madison Company liquid level switch products, the reliability and low cost of our reed switch technology provides for excellentservice life.
Our standard subminiature models (see back sideof this sheet) are also available as combinationsensors designed to provide point level indicationand temperature indication in one unit. Thetemperature sensor can be a thermocouple type K, J or T or platinum thin film RTDs.
Madison’s engineering department can design aswitch specific to your application. We havemounted this micro-miniature switch tosubassembly configurations for labor savings andenhanced product quality.
Above: Standardsubminiature liquidlevel switches
Right: Side-by-sidesize comparison withMadison’s miniatureswitches
LL
Representative Sizes
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-24 © Copyright Madison Company – 10/10
All specifications are subject to change without notice.
Standard Subminiature Models
M3326
M3326-NO
M3326-NPT
M3326-NPT-NO
MT3920-1*
MT3920-2**
M4035
M4035-B
M3326-SM
FloatMaterial
PP
PP
PP
PP
PP
PP
PP
PP
PP
StemMaterial
PP
PP
PP
PP
PP
PP
316SS
316SS
PP
Max.Temp.
105˚C
105˚C
105˚C
105˚C
105˚C
105˚C
105˚C
105˚C
105˚C
Max.PSIG
50
50
50
50
100
100
100
100
50
FloatSG
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.85
NominalVA
15
15
15
15
15
15
15
15
15
Lead Wires
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
22 AWG, Teflon®, 24”
Fitting
3/8-16
3/8-16
1/8” NPT
1/8” NPT
3/8-16
3/8-16
1/8” NPT
3/8-24
3/8-16
* with Type J Thermocouple; ** with Type K Thermocouple
1.85"(47)
1.25"(31.7)
.58"(14.7)
"O"Ring
3/8-16 THD
.63"(16.0)
1.68"(42.6)
1.25"(31.7)
.58"(14.7)
.63"(16.0)
1/8" NPT
3/8 x 24 THREAD.75” (19.1) LONG
2 x 24” LEAD WIRES24 AWG TEFLONINSULATED
APPROX.ACTIVATIONLEVEL
.56” HEX(14.2)
.50"(12.7) .95"
(24.1)
MOUNTING NUT(SUPPLIED)
ø.78"(19.8)
1.70"(43.2)
M3326, M3920 M3326-NPT M4035-B
Consult factory for approvals for each model. For design or material modifications, you can complete aproduct specification worksheet found in this catalog and on our website, or contact one of our salesrepresentives with your specific requirements. Alternative materials or colors may require a a minimumorder quantity.
Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
LL
M SeriesSuspendible/SubmersibleLeak Detection Switch
Features
• Affordable
• Easy installation; compact size
• Highly reliable; long service life
• No calibration required
• Suitable for water and hydrocarbons
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 5/05 LL-25
Madison Company offers a standard model M3782liquid level switch that can be fully submerged with 20’ of 22 AWG HALAR® jacketed 2-conductorwire. This model is weighted for suspension in non-magnetic tanks and can be used in conjunctionwith a still pipe. Its materials are suitable for water,hydrocarbons and certain chemicals. ContactMadison Company to check on material compatibility.
This low-cost switch is ideally suited for sumps,dispenser pans, monitoring wells and double-walltanks where monitoring for leaks is required. Thedepth of the vertical mount can be easily adjusted bycutting the cable length as required.
This standard model can also be customized to meetyour specific application needs. Simply complete the M Series Specification Worksheet and send it toMadison Company for a quotation.
M3782
HALAR® is a registered trademark of Ausimont USA, Inc.
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-26 © Copyright Madison Company – 7/08
All specifications are subject to change without notice.
MaterialsStem and Extension – Brass
Float – Buna-N
Slosh Shield – PBT (optional 316SS slosh shield also available)
Cable – 20’ 22 AWG, HALAR jacketed 2-conductor cable with watertight connector
OperationNormally Closed (NC), open on liquid rising
Options– Wire lengths– Wetted materials
Wire Leads
4.06"(103.1)
ø1.44"(36.6)
M3782Current and Voltage Ratings
Current Amps(Resistive)
0.140.280.070.28
Voltage
240 AC120 AC120 DC
24 DC
LL
M SeriesBilge/Bottle & Submersible Switches
Features
• Available with anodized or electropolish finish for harsh environments
• Universal design for bilge or bottle switch applications
• Reliable reed switch technology
• Multiple submersible switch models are also available as standard products(see reverse side)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 5/07 LL-27
Madison Company offers its newest universaldesign for bilge and external tank applications.The M4182 Series is a standard liquid level switchproduct available in four housing materialconfigurations. These Bilge/Bottle models allow forin-field replacement of the float switch, helping toensure minimal down time in applications wherethey are used. The same highly reliable liquid levelswitch technology used in other MadisonCompany reed switch products is also used in the M4182.
This design supplements the M4147 bracket-mounted liquid level switch and the othersubmersible switches referenced on the back sideof this sheet, which have been long-standingsolutions for bilge and sump applications. TheM4182 family of designs can also be bracketmounted and encloses the float for purposes ofminimizing the effect of turbulence and possiblecontamination of the float’s performance.
Madison Company can also provide application-specific designs for external tank and bilgeapplications.
M4182 Bottle Switch for bilge and external tank applications, available in
stainless steel (left) and aluminum (right)
LL
M4182 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-28 © Copyright Madison Company – 11/08
All specifications are subject to change without notice.
Specific Gravity – Float: 0.70
Max. Pressure – M4182-SS: 300 PSIGM4182-AL: 150 PSIG
Max. Temperature – M4182-SS: 200˚C (392˚F)M4182-AL: 105˚C (221˚F)
Switch Operation – SPST, normally closed
Electrical – 70 VA; 240 VAC resistive load
Other Submersible Switches
M4182-SS
M4182-SS-EP
M4182-AL
M4182-AL-A
HousingMaterial
316SS
316SS
6061 Aluminum
6061 Aluminum
FloatMaterial
316SS
316SS
Polypropylene
Polypropylene
Finish
Natural
Electropolish
Natural
Anodized (Clear)
FLOAT
MATL.
316SS
Buna-N
PP
Buna-N
316SS
MAX. TEMP.
(CELSIUS)
110˚
105˚
105˚
93˚
100˚
NOMINAL
VA
60
60
60
60
60
MAX.
PSIG
85
150
100
85
30
FLOAT
SG
0.55
0.45
0.75
0.45
0.64
MODEL
MSB5600
MSB7800
MSB8800
M3200
M3842
HOUSING
MATL.
316SS
PBT
PP
316SS
316SS
MSB5600MSB7800
M3200M3842
MSB8800
ø 2.38”(60.5)
Field-replaceable switch
1.71”(43.4)
4.3”(109.2)
2.0”(50.8)
3/4” NPTfluid connections
7.2”(182.9)
1.24”(31.5)
24” LeadWires
1/2” NPTfemale conduitconnection
Approx.actuation point
With optional mountingbracket kit
(stainless steel)
For 1/2” bolt(top & bottom)
3.75” (95.3)
5.38”(136.7)
ø 2
Includes self-test feature
Field replacement liquid level switch for the M4182-SS and M4182-SS-EP is the M5002-7801; for the M4182-AL andM4182-AL-A, it is the M5002-7802. Consult factory for availability and prices.
LL
M SeriesAdjustable Switch Height Feature
Features
• Common level switches allow end user to adjust switch depth or height
• Bracket designs can provide for easy mounting to tanks
• Can overcome uneven tank stands to allow for accurate low level indication
• User can change operation from normally closed to normally open
• Engineered configurations available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/09 LL-29
M4302-7807-x and M5602-7808-x adjustable-height liquid level switches
Madision Company’s engineered designs can provide a liquidlevel switch for tank applications with slight changes in thelevel at which the switch signal is needed, to accommodatemultiple tank designs or conditions.
In the M4302-7807 and M5602-7808 base models, downwardswitch height adjustment by the end user can be as much as2”, and an upward adjustment could be from 9” to 69”. Thiswould allow a series of tanks to use the same level switchconfiguration and provide easier field adjustments for low levelindication. Multi-level indications can also be provided.
The adjustment is done by loosening the compression fittingon the top of the 2’’-11.5 NPT pipe plug and moving the entirestem up or down as needed in the application. The M4302-7807-x series is manufactured with nylon ferrules in thecompression fitting. The M5602-7808-x series is supplied withTeflon ferrules in the compression fitting. These types offerrules allow the end user to adjust the length multiple times.The retaining rings are not to be moved, unless the operationneeds to be changed from normally closed to normally open.
The picture inset at right shows twoapproaches where bracket designscan also be used to provide heightadjustability in addition to multipleactivation points in a single tank.
Several standard MadisonCompany designs utilizing full-sizefloats are listed on the reverse sideof this page. Miniature-size stemsand/or floats can be engineered,which would additionally allow forMadison’s Ultra-Low-Level float options to be utilized.
LL
M4302-7807 Specifications (representative standard designs)
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-30 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Wetted Materials – Stem and Fittings: BrassFloat: Buna-N Grip Rings: Beryllium Copper
Operation – Normally closed, opens on rising level. User can reverse operation.
Max. Temperature – 105˚C (221˚F)
Max. Pressure – 150 PSIG
Float Specific Gravity – 0.45
Electrical Rating of Switch – 60 Watt, SPST
Mounting – 2”-11.5 NPT Pipe Plug
M4302-7807-1M4302-7807-2M4302-7807-3M4302-7807-4M4302-7807-5M4302-7807-6
TotalLength
12” (30.5cm)
24” (61.0)
36” (91.4)
48” (121.9)
60” (152.4)
72” (182.9)
Adjustable Switch LevelDown
2” (50.8mm)
2” (50.8)
2” (50.8)
2” (50.8)
2” (50.8)
2” (50.8)
Up
9” (22.9cm)
21” (53.3)
33” (83.8)
45” (114.3)
57” (144.8)
69” (175.3)
Level 1(± 0.125”)
10.5” (26.7cm)
22.5” (57.2)
34.5” (87.6)
46.5” (118.1)
58.5” (148.6)
70.5” (179.1)
M5602-7808 Specifications (representative standard designs)Wetted Materials – 316 Stainless Steel
Operation – Normally closed, opens on rising level. User can reverse operation.
Max. Temperature – 200˚C (392˚F)
Max. Pressure – 200 PSIG
Float Specific Gravity – 0.55
Electrical Rating of Switch – 60 Watt, SPST
Mounting – 2”-11.5 NPT Pipe Plug
M5602-7808-1M5602-7808-2M5602-7808-3M5602-7808-4M5602-7808-5M5602-7808-6
TotalLength
12” (30.5cm)
24” (61.0)
36” (91.4)
48” (121.9)
60” (152.4)
72” (182.9)
Adjustable Switch LevelDown
2” (50.8mm)
2” (50.8)
2” (50.8)
2” (50.8)
2” (50.8)
2” (50.8)
Up
9” (22.9cm)
21” (53.3)
33” (83.8)
45” (114.3)
57” (144.8)
69” (175.3)
72” ± 2”(1828.8 ± 50.8)
2.0” (50.8),adjustable
1/2-14 NPTconduit connection
Compression fittingwith nylon ferrulesfor adjustability
2-11.5 NPTpipe plug
Level 1
Total Length
2.10” max.(53.3)
ø 2.13” max.(54.1)
72” ± 2”(1828.8 ± 50.8)
2.0” (50.8),adjustable
1/2-14 NPTconduit connection
Compression fittingwith nylon ferrulesfor adjustability
2-11.5 NPTpipe plug
Level 1
Total Length
2” max. (50.8)
ø 1.25” max.(31.8)
Level 1(± 0.125”)
10.5” (26.7cm)
22.5” (57.2)
34.5” (87.6)
46.5” (118.1)
58.5” (148.6)
70.5” (179.1)
LL
M SeriesInterstitial Switch
Features
• Thin profile
• Wide range of electrical voltages
• Full choice of alarms or control systems
• Easy installation
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 1/07 LL-31
M3769
Madison Company’s Interstitial Switch is a thinprofile device designed for double-wall tanks and pipes. The 3/8” high switch is ideal forunderground tanks and piping where the double-wall construction needs to be monitored forproduct release from the inner tank. It can alsobe used to signal the presence of liquid leaks oroverflows in any containment area by connectingto a suitable alarm indicator. The avoidance ofpotential cleanup costs through early detection of leaks is well worth the cost of this unit.
The M3769 Interstitial Switch is constructed of a Valox 420 housing and foamedpolypropylene float with a stainless steel pivotpin. The standard M3769 model comes with 10’ of Halar-jacketed cable.
Shown in Open Position
Cable toCustomerController
Double-WalledPipe or Tank
M3769
Typical Installation
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-32 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Materials –
Body – Valox 420
Float – Foamed polypropylene
Cable – 10’, two conductorsHalar jacketed
Temperature – 105˚C (221˚F), maximum
Pressure – 50 PSIG, maximum
Switch Rating – 30 Watt, SPST
Operation – Normally Closed (NC), open on liquid rising
Approvals – UL, CE
3.00"(76.2)
1.50"(38.1)
0.375" (9.53)
10' Cable Leads
Switch Housing
Float
Pivot Pin
Attach String Here to Pull Through Tank
.75" REF (19.1)
Current and Voltage Ratings –
M3769
Current Amps(Resistive)
0.140.280.070.28
Voltage
240 AC120 AC120 DC
24 DC
LL
M SeriesDrum Level Indication
Features
• Multiple drum level choices
• Easy mating to standard drum bungs
• Remote alarm and power abilities
• Choice of contact or non-contact level indication
• Choice of high and/or low level indication and alarm
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 LL-33
Madison Company offers several level indicationproducts designed specifically for standard 20-, 30-and 55-gallon drums. These level indicators will fit-updirectly with standard 3/4” NPT bungs.
This family of standard level indicators comes in low-level, high-level and multi-level designs, for both low-and high-level indication. The basic level switchesrequire a power source. When configured with analarm, battery power is on-board.
Optional alarms are available in either a fixed-mount(to the level switch) or a remote-mount design. Thisoption provides both the level switch and the alarmwith battery power for ease of use in remote siteswhere a power source is not readily available.
For those drum applications requiring a non-contactlevel device, the Madison U3M Mini Ultrasonic Sensoris the way to go. This sensor also mounts directly intoa 3/4” NPT bung and requires a power source. Thesensor is calibrated by the user using an on-boardpush button. The U3M is available in twoconfigurations: one that is designed for infrequentremoval and the other with a connector lead-wiretermination for quick disconnect and removal from thedrum head. These sensors are configured withRS485 communications for PC networks.
Above: Madisonoffers severalstandard and
non-contact sensorsfor drum levelindication
Left: Mini UltrasonicSensor mounted to
drum head
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-34 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
M4168-X (4168-1 without alarm)Wetted Materials:
Stem and Fittings – BrassFloats – Buna-NGrip Rings – Beryllium Copper
Maximum Temperature: 105˚C (221˚F)Maximum Pressure: 150 PSIGFloat Specific Gravity: ~ 0.5Reed Switch Rating: 30-Watt SPSTLead Wires: 2 or 4 conductor, 22 AWG,
Halar-jacketed; 72” length (±2”)
M4169-X (M4169-1 without alarm)Wetted Materials:
Stem, Fittings and Floats — 316SSGrip Rings — PH-15-7 Mo SS
Maximum Temperature: 150˚C (302˚F)Maximum Pressure: 250 PSIGFloat Specific Gravity: 0.73 (±0.02)Reed Switch Rating: 30-Watt SPSTLead Wires: 2 or 4 conductor, 22 AWG,
Halar-jacketed; 72” length (±2”)
U3M-XWetted Materials: PVCMaximum Temperature: 60˚C (140˚F)Maximum Pressure: 30 PSIGLead Wires: 6 conductor, 24 AWG,
shielded, PVC-jacketed; 60” length (±2”)Electrical: 12-30 VDC, 0.07 A max. @ 24 VDC
Liquid-tightfitting, typical
M
32” ± 0.125”(812.8 ± 3.2)
31” ± 0.125”(787.4 ± 3.2)
actuation point
1” ± 0.125”(25.4 ± 3.2)
actuation point
3/4-14 NPT,typical
31” ± 0.125”(787.4 ± 3.2)
actuation point
32” ± 0.125”(812.8 ± 3.2)
72” ± 2”(1828.8 ± 50.8),
typical
1.25” (31.8)max.
ø .90” (22.9)max.
2” ± 0.125”(50.8 ± 3.2)
1” ± 0.125”(25.4 ± 3.2)
actuation point
Liquid-tightfitting, typical
32” ± 0.125”(812.8 ± 3.2)
31” ± 0.125”(787.4 ± 3.2)
actuation point
1” ± 0.125”(25.4 ± 3.2)
actuation point
3/4-14 NPT,typical
31” ± 0.125”(787.4 ± 3.2)
actuation point
32” ± 0.125”(812.8 ± 3.2)
72” ± 2”(1828.8 ± 50.8),
typical
1.59” (40.4)max.
ø .90” (22.9)max.
2” ± 0.125”(50.8 ± 3.2)
1” ± 0.125”(25.4 ± 3.2)
actuation point
Electrical Data for M4168-1 & M4169-1
Watts
30303030
Voltage
240 VAC120 VAC120 VDC24 VDC
Amps(Resistive)
0.140.280.070.28
Alarms• Fixed mount to level switch 4168-X
or 4169-X• LED alarm standard• Audible alarm option (to replace LED or
in conjunction with an LED alarm)• All alarms are battery powered
Fixed-Mount Models
M4168-1-FMM4168-2-FMM4168-3-FMM4169-1-FMM4169-2-FMM4169-3-FM
Remote-Mount Models
M4168-1-RMM4168-2-RMM4168-3-RMM4169-1-RMM4169-2-RMM4169-3-RM
Alarm Level
HighLow
High & LowHighLow
High & Low
Alarm Level
HighLow
High & LowHighLow
High & Low
Electrical Connectorsor Lead Wires?
NoYesNoYesNoYesNoYes
Non-Contact Models
U3M-148-3/4U3M-148-3/4-18P154U3M-148C485-3/4U3M-148C485-3/4-18P154U3M-148C485R-3/4U3M-148C485R-3/4-18P154U3M-148R-3/4U3M-148R-3/4-18P154
RS485Communications?
NoNoYesYesYesYesNoNo
Relay?
NoNoNoNoYesYesYesYes
Operation (Dry Conditions)
NONC
NO/NCNONC
NO/NC
Operation (Dry Conditions)
NONC
NO/NCNONC
NO/NC
ø4.0"(ø101.6)
STANDARD CABLE OPTIONAL CABLE
1" NPT
4.1"(104.1) 3.125"
(79.4)1.95"(49.5)
ø1.125"(ø28.6)U3M-X
M4169-3
M4169-2 M4169-1
M4168-3 M4168-2
M4168-1
Standard Models
Note: The remote distance from top of drum to alarm box is 72”.
LL
M SeriesSingle-Level RefrigerantRecovery Switch
Features
• Highly reliable
• Float options and custom designs available
• UL, CSA and CE approved
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 LL-35
M5042
Madison Company’s M5042 and M8042 models are 80% shut-off switches for all standard 30- and 50-pound D.O.T. approved recovery tanks. They are designed specifically to meet EPA directives foroverfill protection of refrigerant recovery tanks.
Madison Company can provide customized switchdesigns to meet specific customer needs, includingmultiple floats, actuation points or termination styles.The Madison M and MT Series Specification Sheetshould be used to define custom requirements.
Models M5042 and M8042 (model M8042 not shown)have wetted materials that are compatible with allcommercially available refrigerants. Their PSIG rating is 300, which is standard for 30- and 50-pound D.O.T.refrigerant tanks.
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-36 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Materials
Body and Float – M5042 – Yellow Brass stem and fitting; 316 Stainless Steel float M8042 – Yellow Brass stem and fitting; Teflon® float
Operating SpecificationsTemperature – 150˚C (302˚F) max.
Pressure – 300 PSIG, max.
Specific Gravity – 0.70 (M5042), 0.50 (M8042)
Switch Operation – SPDT normally closed (dry state)
Electrical Rating – 60 VA resistive; 120/240 VAC, 5-30 VDC
Mounting – Vertically mounted with 3/4” NPT; fitting hex is 1-1/16”
Connector OptionsM5042-134-3 = 3-pin connector, Brad Harrison 70303 Series or equivalent
M5042-134-4 = 4-pin connector, AMP (TYCO) CPC connector #20606-1 or equivalent
M8042-134-3 = 3-pin connector, Brad Harrison 70303 Series or equivalent
M8042-134-4 = 4-pin connector, AMP (TYCO) CPC connector #20606-1 or equivalent
NOTE:There are no user-serviceable components, and the location of the float retaining rings must not be changed. If service or repair is required, call for a return authorization.
3.31"(84.1)
5.31"(134.9)
7.28" max.(184.9)
3/4" NPT
SWITCH ACTUATIONPOINT
ø.88"(22.4)
3.31"(84.1)
4.75"(120.7)
6.66" max.(169.2)
3/4" NPT
SWITCH ACTUATIONPOINT
M5042
M8042
LL
M SeriesSide-Mounted Switch with Spade Connector
Features
• Integral male spade connectors
• Simplified electrical and mechanical installation
• Compact size
• Improved field maintainability
• Choice of materials for various liquid applications
• Available with wire leads
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 LL-37
M8725 Polypropylene material (top) M7725 PBT material (bottom)
Madison Company offers a standard liquid levelside-mounted switch that has a 1/4” male spadeconnector for simplified electrical installation. Themounting is a 1/2” NPT thread for a vessel wallthrough hole. Both design features provide foreasy field maintenance.
The M7725 is constructed of PBT (PolybutyleneTerephthalate) with an operating temperature upto 130˚C for most hydrocarbon liquids. PBTshould not be used in water over 65˚C. TheM8725 is all polypropylene, for general-purposeapplications and those involving highly acidicliquids. Its operating temperature should notexceed 105˚C.
The M8750 and M8755 (not shown) are similar to the M8725 but come with 24” 22 ga. MTW wire leads. All models are UL, CSA, CE and NSF approved.
Madison Company also offers designs engineeredspecifically for unique application needs.
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-38 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
MaterialsBody and Float – M7725* – PBT (Polybutylene Terephthalate)
M8725 – Polypropylene
Operating SpecificationsTemperature – M7725* – 130˚C (266˚F) max.
M8725 – 105˚C (221˚F) max.
Pressure – 100 PSIG, max.
Specific Gravity – M7725* – 0.70M8725 – 0.60
Switch Operation – Normally Open (NO), close on liquid risingNormally Closed (NC), open on liquid rising
2.75" (69.85) max.
1/2" NPT
.29"(7.37)
2 x .25" x .03"(6.35 x 0.76)Male QC tabs
1" Hex.
.56" (14.22) min.
.60" (15.24) min.
.621" (15.77)
MAX
PSIG
100
100
FLOAT
SG
0.60
0.70
SWITCH
OPERATION
NO or NC
NO or NC
NOMINAL
VA
30
30
THREADS
1/2” NPT
1/2” NPT
MODEL
M8725
M7725*
MAX TEMP
(CELSIUS)
105˚
130˚
* Not for use in water over 65˚C
LL
M SeriesTilt Float Switch
Features
• Low cost
• Easy installation
• Versatile in application
• Custom lead lengths available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 5/09 LL-39
Madison Company’s Tilt Float Switch is aninexpensive, efficient and highly reliable leveldetector for open vessels, sumps and ponds.
The molded rubber float has an integral threeconductor cable and operates on a micro-switchdevice that is located inside the float on an anti-vibration mount.
The rubber float is constructed of ethylenepropylene diene (EPDM), a synthetic rubber withrigid and durable characteristics for long servicelife and resistance to heat, oxidation, ozone andaging due to weather. As a non-polar elastomer,EPDM has good electrical resistivity, as well asresistance to polar solvents such as water, acids,alkalies, phosphate esters and many ketones and alcohols.
The basic operating principle is that as the fluidlevel rises the float will rise, causing the micro-switch to tilt and generate a signal that can beused to start or stop a pump, open or close avalve or actuate indicator alarms as required.
Float travel is approximately ± 45˚ arc from itsnominal position.
M4189 Tilt Float Switch
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-40 © Copyright Madison Company – 5/09
All specifications are subject to change without notice.
Contact Rating – 16(8)A 250V ~ 16(4)A 380V; Form C (SPDT)
Max. Temperature – 70˚ C (158˚F)
Standard Cable Length – 6.5’ (2 m); Additional lengths available. Lengths above 2 meters will have asplice in the length. Additional cable will be neoprene jacketed, andadhesive-lined polyolefin shrink tube will be used to insulate the splice.Non-spliced lengths can be special ordered upon request.
Max. Submerged Depth – 65’ (20 m)
Max. Working Pressure – 1 bar
Circuit Breaking Capacity – Directly 1KW with 250V
Wetted Materials – Float: EPDM rubber Cable: PVC jacket Weight: Polypropylene sealed housing
Specific Gravity – Stem & Float: 2.16 g/cm3
– Operational in specific gravity from 0.9 to 1.3
Mounting & InstallationThere are no specific installation concerns. However, the lead cable should be supported in anenclosed tank. Additionally, in an open tank, sump, or pond, it is advantageous to clip the lead cable tothe side, especially if excessive turbulence is experienced (a nylon cable-tie is included).
To alleviate the effects of rapid switching conditions if such turbulence is expected, it is recommendedthat a maintaining circuit be used to both safeguard the micro-switch and cut out any chatter from thestarters of associated equipment, such as pumps.
An optional stabilizing weight and rubber “O” ring are included with the M4189 Tilt Float Switch. Thismay be installed at any point on the lead cable.
LL
M SeriesStainless Steel “Side Kick”Side-Mounted Switch
Features
• Ideal for heavy-bodied liquids or fluids containing metal particles
• Compact installed height of 3-1/2” from switch to float
• Reed switch will not come in contact with the liquid
• All stainless steel construction
• Float is attached to an extended pivot arm
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 LL-41
M3827-2
The M3827 is a traditional style reed switch in a new design. This all stainless steel side-mounted switch is engineered such that themagnetically-actuated reed switch will notcome in contact with the fluid being monitored.The float is attached to an extended pivot armthat, when moved, triggers the switch function.
This design makes the M3827 ideal for use in heavy-bodied liquids or in fluids containingmetal particles that would otherwise beattracted to a conventional style float. Thislevel switch has a compact installed height of 3-1/2” from switch to float and is availableNormally Open (NO) or Normally Closed (NC).The M3827 is offered in a choice of threemounting styles: 1/8” NPT, 1/2” NPT and 1/2-13 bulkhead.
LL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-42 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Normally Open
MaterialsBody – Stainless Steel
Float – Stainless Steel
Gasket – Silicone*
Operating SpecificationsTemperature – 200˚C (392˚F), maximum
Pressure – 50 PSIG, maximum
Specific Gravity – 0.60
Switch – 30 VA, SPST
Operation – Normally Open (NO), close on liquid risingNormally Closed (NC), open on liquid rising
5.12" (130.05)
6.25" (158.75) max.
3.50"(88.90)
1/2-13THD
1/2" NPT
1/8" NPT
5.77" (146.56)~
5.77" (146.56)~
5
5.25" (133.35) max.
2.79"(70.87)
3.79"(96.27)
Normally Closed
MAX.
PSIG
50
50
50
50
50
50
FLOAT
SG
0.60
0.60
0.60
0.60
0.60
0.60
SWITCH
OPERATION
NC
NC
NC
NO
NO
NO
NOMINAL
VA
30
30
30
30
30
30
THREADS
1/2-13 Bulkhead
1/2" NPT
1/8" NPT
1/2-13 Bulkhead
1/2" NPT
1/8" NPT
MODEL
M3827-1*
M3827-2
M3827-3
M3827-1NO*
M3827-2NO
M3827-3NO
MAX. TEMP.
(CELSIUS)
200˚
200˚
200˚
200˚
200˚
200˚
* Silicone gasket supplied on M3827-1 and M3827-1NO
LL
Sensor Type: Thermocouple Thin-Film RTD Bimetal ThermistorType K 100 Ohm Snap ActionType J 1000 Ohm Creep ActionType T
Temperature Range:
Actuation Point (Open/close on rise at temp.): Other Considerations:
Madison Company can engineer single-point liquid level switches to meet your application needs. Pleaseprovide the information requested below so that our Engineering Department can determine the appropriateswitch design for your application.
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
ENVIRONMEN
TELEC
TRICAL
PHYS
ICAL
PROJECT
NOTES
DES
IGN
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Application Description:
Fluid: Tank Materials:
Temp. Range: Max. Pressure:
Misc. Conditions (vibration, food contact, hazardous location, turbulence, solids, approvals [i.e. UL, NSF] etc.):
Current: Voltage:
What type of device is being controlled:
4-20 mA Transmitter: o Yes o No
Controller required (refer to Accessory section for model):
Port Type: Inside/Outside Mount:
Lead Length: Cable/Flying Leads:
Connector/Terminations:
Misc:
TEMPE
RAT
URE
Unit Volume (monthly):
Packaging/Labeling:
Pricing Target:
Stocking/Shipping Requirements:
Design Completion Date:
First Delivery Date:
Sensor solutions for today and the future™
M & MT Series Specification SheetSingle-Point Liquid Level Switch (with temperature option)
© Copyright Madison Company – 2/05 LL-43
LL
LL
M SeriesMulti-Point Liquid Level Switches
Features
• Multi-point
• Customer-designed
• Magnetic reed switch technology
• High reliability
• Wide selection of available materials
• Three basic sizes: full, miniature and subminiature
• Direct interface to controllers available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 3/11 LL-45
A selection of engineered multi-level switches
Madison Company offers a complete lineof Standard and Configured (slightlymodified Standard designs) models. These products continue to meet theneeds of applications in many markets, at competitive prices. In addition, Madison Company offers the capability to design specific liquid level switches for OEM applications that require unique considerations in materials,configurations and system interfacing.
Engineered designs incorporate over 50 years of experience in liquid level switchapplications in a variety of environmentsand installation configurations. Highreliability of the magnetic reed switchtechnology assures repeatability at aneconomical price. Our design experienceand flexible manufacturing techniques alsooffer customers many value-added designand assembly options to reduce theirproduct cost.
LL
Material Selection Guide
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
LL-46 © Copyright Madison Company – 6/08
All specifications are subject to change without notice.
The first consideration is the type of liquid, temperature and pressure to which the switch will be subjected. Madisonmanufactures liquid level switches in various styles, in avariety of materials, to cover a broad range of conditions.Following are some basic recommendations for selectingthe proper liquid level switch material for your application.
Material
316 Stainless Steel
PolypropylenePolysulfone
Brass & Buna-NPBT & Buna-N
KynarPTFE
CPVC
Application
For high-temperature (to 300˚C), high-pressure (to 300 PSIG) andcorrosive conditions. Commonly used in food processing, medical,heating and cooling equipment.
For acidic conditions, such as found in electroplating and metalcleaning. Another choice for lower-temperature (to 105˚C) foodprocessing applications (Madison Company uses only polypropylenethat is FDA-approved for food contact). Also a good choice forgeneral-purpose applications in commercial or consumer appliancesand equipment. Available in white and other colors.
The selection for petroleum-based liquids, such as lubricating oils,gasoline and diesel fuels. Widely used in storage tanks of vehicles,generators, transmissions and hydraulic systems. Other uses are inlubrication, recovery, refining and fuel processing equipment. Please note: PBT is not suitable for use in temperatures above 130˚C.
Chemical- and solvent-resistant properties make this material aproblem solver for many applications. Its high-purity nature is idealfor food handling and sensitive laboratory or test equipment.
Good for water, acids, bases and oil products. Not suitable for use intemperatures above 90˚C.
Once a suitable material has been selected, the type of switch and configuration are the nextconsiderations. Madison Company stocks a full line of standard products that can meet therequirements of many applications. For specific designs, Madison can custom build, to order,switches with an infinite number of variations and options. Please utilize our multi-levelspecification sheet which, when completed, will allow our engineering department to better meet your needs.
COMPONENT
See Approvals pages in Reference Section
LL
Multi-point switches are available in many materials and configurationsand can contain as many float actuation points as the application andswitch design may allow (normally up to five). These rugged units canbe mounted within any vessel, utilizing the mounting options shownabove, or customized to the specific application. The actuation pointsare defined by the customer and can be engineered to address offsetlocations within the vessel, allowing for the bypass of obstructions orsaddle type tanks. For turbulent conditions, slosh shields, as well aselectronic interface components and accessories, can be provided.Temperature sensors can also be incorporated into these models.
MODEL
M5602-XXXX
M5605
M4602-XXXX
M8602-XXXX
M5002-XXXX
M4402-XXXX
M8002-XXXX
DWG
NO.
7
7
8
8
9
10
10
FLOAT
MATL
316SS
316SS
Buna-N
PP†
316SS
Buna-N
PP†
STEM
MATL
316SS
316SS
316SS
316SS
316SS
316SS
316SS
MAX TEMP
(CELSIUS)
200°
200°
105°
105°
200°
105°
105°
MAX
PSIG
200
200
150
100
300
150
100
FLOAT
SG
0.55
0.55
0.45
0.75
0.70
0.45
0.80
NOMINAL
VA
60
60
60
60
30
30
30
LEAD WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C,D,E,I
C
A,B,C
A,B,C,D
A,B,C,D,I
A,B,C
A,B,C,D
PIPE PLUG
2"
–
2", 1-1/2"
2", 1-1/2"
2", 1-1/2", 1-1/4"
2", 1-1/2", 1-1/4"
2", 1-1/2", 1-1/4"
FLANGE
SPECIFY SIZE
–
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
MOUNTINGS – NPT
Most Common Mountings and Options*
2.13" dia. max.(54.1)
1" dia. max.(24.4)
1.13" dia. max.(28.7)
1.50" dia. max.(38.1)
DWGNo. 7
Multi-Point Switches
Multi-Point Switch KitThis kit provides the user with the opportunity to optimize their own multi-point switch and fabricate it in the field fromthe kit components. The kit is furnished with two floats and a 2” pipe plug. Maximum stem length is 36” (914.4mm). Please contactfactory for additional components. See Multi-Point Switch Kits page for full specifications.
**
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/09 LL-47
† Also available in Polysulfone (consult factory). PP=Polypropylene ** Refer to Approvals pages in Reference Section. Individual product explosion-proof (E) approvals vary. Consult factory for current product listings.
MODEL
M5602-XXXX
M5605
M4602-XXXX
M8602-XXXX
M5002-XXXX
M4402-XXXX
M8002-XXXX
MALE THREAD
3/8", 1/2"
1/2"
3/8", 1/2"
3/8", 1/2"
1/8", 1/4", 3/8", 1/2"
1/8", 1/4", 3/8", 1/2"
1/8", 1/4", 3/8", 1/2"
BULKHEAD
1/2-13, 3/4-10
–
1/2-13, 3/4-10
1/2-13, 3/4-10
3/8, 3/4-10
3/8, 3/4-10
3/8, 3/4-10
SPST 100 W
OPTION
YES
NO
YES
YES
NO
NO
NO
SPDT 25 W
OPTION
YES
NO
YES
YES
NO
NO
NO
DWGNo. 8
DWGNo. 9
DWGNo. 10
All specifications are subject to change without notice.
M Series Stainless Steel Liquid Level Switches
LL
* An expanded list of U.S. fittings and European BSPP and BSPT fittings is available in our e-catalog at www.madisonco.com.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.LL-48 © Copyright Madison Company – 4/09
M Series Plastic Liquid Level Switches
Multi-point switches are available in configurations containing up tosix different levels, providing maximum flex i bil i ty for each user. Theserugged units can be mounted within any vessel, utilizing either malepipe threads, pipe plugs, flanges or bulk head fittings. The length ofeach switch, as well as the location of each of the floats, may bees tab lished by the designer. For difficult in stal la tions, stems can bebent to bypass obstructions within the vessel. Slosh shields are alsoavailable for turbulent conditions. Temperature sensors can beincorporated into these models.
1" dia. max.(24.4)
1.50" dia. max.(38.1)
DWGNo. 38
DWGNo. 37
MODEL
M8802-XXXX
M8080-XXXX
M8085
M6602-XXXX
DWG
NO.
37
38
38
37
FLOAT
MATL
PP†
PP†
PP†
PP
STEM
MATL
PP†
PP†
PP†
CPVC
MAX TEMP
(CELSIUS)
105˚
105˚
105˚
90˚
MAX
PSIG
100
25
100
100
FLOAT
SG
0.75
0.80
0.80
0.75
NOMINAL
VA
60
30
30
60
LEAD WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C,I
A,B,C,D,I
C
A,B,C
MODEL
M8802-XXXX
M8080-XXXX
M8085
M6602-XXXX
MALE THREAD
1/2"
1/8", 1/4", 1/2"
1/4"
1/2", 3/4", 1"
PIPE PLUG
2", 1-1/2"
2", 1-1/2", 1-1/4"
–
1-1/2", 2", 2-1/2"
FLANGE
SPECIFY SIZE
SPECIFY SIZE
–
2", 3"
BULKHEAD
1/2-13
1/2-13
–
–
MOUNTINGS – NPT SPST 100 W
OPTION
YES
NO
NO
YES
SPDT 25 W
OPTION
YES
NO
NO
YES
Most Common Mountings and Options*
Multi-Point Switches
**
† Also available in Polysulfone (consult factory). PP=Polypropylene ** Refer to Approvals pages in Reference Section
Multi-Point Switch KitThis kit provides the user with the opportunity to optimize their own multi-point switch and fabricate it in the field fromthe kit components. The kit is furnished with two floats and a 2” pipe plug. Maximum stem length is 36” (914.4mm). Please contactfactory for additional components. See Multi-Point Switch Kits page for full specifications.
LL
* An expanded list of U.S. fittings and European BSPP and BSPT fittings is available in our e-catalog at www.madisonco.com.
Multi-point switches are available in configurations containing up to sixdifferent levels, providing maximum flex i bil i ty for each user. These ruggedunits can be mounted within any vessel, utilizing either male pipe threads,pipe plugs, flanges or bulk head fittings. The length of each switch, as wellas the location of each of the floats, may be es tab lished by the designer.For difficult in stal la tions, stems can be bent to bypass obstructions withinthe vessel. Slosh shields are also available for turbulent conditions.Temperature sensors can be incorporated into these models.
MODEL
M4302-XXXX
M4502-XXXX
M5042-XXXX
M5402-XXXX
M8042-XXXX
M8402-XXXX
DWG
NO.
25
27
26
24
27
25
FLOAT
MATL
Buna-N
Buna-N
316SS
316SS
PP
PP
STEM
MATL
Brass
Brass
Brass
Brass
Brass
Brass
MAX TEMP
(CELSIUS)
105°
105°
200°
200°
105°
105°
MAX
PSIG
150
150
300
200
100
100
FLOAT
SG
0.45
0.45
0.70
0.55
0.80
0.75
NOMINAL
VA
60
30
30
60
30
60
LEAD WIRES
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
22 ga. Teflon 24"
APPROVALS
A,B,C,I
A,B,C,I
A,B,C
A,B,C
A,B,C
A,B,C
MODEL
M4302-XXXX
M4502-XXXX
M5042-XXXX
M5402-XXXX
M8042-XXXX
M8402-XXXX
MALE THREAD
1/2"
1/8", 1/4", 1/2"
1/8", 1/4", 1/2"
1/2"
1/8", 1/4", 1/2"
1/2"
PIPE PLUG
2", 1-1/2"
2", 1-1/2", 1-1/4"
2", 1-1/2", 1-1/4"
2"
2", 1-1/2", 1-1/4"
2", 1-1/2"
FLANGE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
SPECIFY SIZE
BULKHEAD
1/2-13
3/8
3/8
1/2-13
3/8
1/2-13
MOUNTINGS – NPT SPST 100 W
OPTION
YES
NO
NO
YES
NO
YES
SPDT 25 W
OPTION
YES
NO
NO
YES
NO
YES
Most Common Mountings and Options*
Multi-Point Switches
**
2.13" dia. max.(54.1)
1" dia. max.(24.4)
1.13" dia. max.(28.7)1.50" dia. max.
(38.1)
DWGNo. 24
DWGNo. 27
DWGNo. 26
DWGNo. 25
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/09 LL-49
PP=Polypropylene ** Refer to Approvals pages in Reference Section
Multi-Point Switch KitThis kit provides the user with the opportunity to optimize their own multi-point switch and fabricate it in the field from the kit components. The kit is furnished with two floats and a 2” pipe plug. Maximum stem length is 36” (914.4mm). Please contactfactory for additional components. See Multi-Point Switch Kits page for full specifications.
All specifications are subject to change without notice.
M Series Brass Liquid Level Switches
LL
* An expanded list of U.S. fittings and European BSPP and BSPT fittings is available in our e-catalog at www.madisonco.com.
Stainless Steel
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.
These easy-to-use, Do-It-Yourself Kits provide the user with the opportunity to optimize their own multi-pointswitches and fabricate them in the field from the kit components. The standard ML-XXXX kits are furnishedwith two floats and a 2” pipe plug. Maximum stem length is 36” (914.4mm). Users who require a 3rd or 4th
level can purchase adder kits as follows:
ML-XXXX-LVL3 to add a 3rd level to the ML-XXXX kitML-XXXX-LVL4 to add a 4th level to the ML-XXXX-LVL3 kitML-XXXX-LVL3&4 to add a 3rd and 4th level to the ML-XXXX kit
Kits are also available with Bent Stem (ML-XXXX-BENT). Bend angle is 90˚.
* Must be ordered in conjunction with ML-XXXX** Must be ordered in conjunction with ML-XXXX-LVL3
All kits are UL and CE approved. For full assembly guidelines and a sample configuration, please visit www.madisonco.com.
Plastic
Brass
LL-50 © Copyright Madison Company – 6/09
M Series Multi-Point Switch Kits
LL
MODELFLOATMATL
STEMMATL
MAX TEMP(CELSIUS)
MAXPSIG
FLOATSG
NOMINALVA
ML-5555 316SS 316SS 200˚ 200 0.55 60
ML-5555-LVL3*
316SS 316SS 200˚ 200 0.55 60
ML-5555-LVL4**
316SS 316SS 200˚ 200 0.55 60
ML-5555-LVL3&4*
316SS 316SS 200˚ 200 0.55 60
ML-5555-BENT
316SS316SS
(90˚ Bend)200˚ 200 0.55 60
MODELFLOATMATL
STEMMATL
MAX TEMP(CELSIUS)
MAXPSIG
FLOATSG
NOMINALVA
ML-8888 PP PP 105˚ 100 0.75 60
ML-8888-LVL3*
PP PP 105˚ 100 0.75 60
ML-8888-LVL4**
PP PP 105˚ 100 0.75 60
ML-8888-LVL3&4*
PP PP 105˚ 100 0.75 60
ML-8888-BENT
PPPP
(90˚ Bend)105˚ 100 0.75 60
MODELFLOATMATL
STEMMATL
MAX TEMP(CELSIUS)
MAXPSIG
FLOATSG
NOMINALVA
ML-4444 Buna-N Brass 105˚ 150 0.45 60
ML-4444-LVL3*
Buna-N Brass 105˚ 150 0.45 60
ML-4444-LVL4**
Buna-N Brass 105˚ 150 0.45 60
ML-4444-LVL3&4*
Buna-N Brass 105˚ 150 0.45 60
ML-4444-BENT
Buna-NBrass
(90˚ Bend)105˚ 150 0.45 60
PP=Polypropylene
INSTRUCTIONSComplete Process Conditions (Table 1). Select float design, stemmaterial and watt rating (Table 2). Select mounting configuration(Table 3). Provide required dimensions and switch operation(Table 4). Mail or fax with purchase order to Madison Company.
All measurements in parentheses are in millimeters.
TABLE 1 PROCESS CONDITIONS
MAX. TEMP. MIN. TEMP.
MAX. PRESSURE SPECIFIC GRAVITY
FLUID
SPECIAL COND.
QUANTITY WIRE LENGTH24" (609.6mm) standard
TEMPERATURE SENSOR OPTION:
THERMOCOUPLE: TYPE J TYPE K TYPE T
THIN-FILM RTD: 100 OHM 1000 OHM
BIMETAL: CREEP ACTION SNAP ACTION THERMISTOR
TEMPERATURE RANGE
OTHER CONSIDERATIONS
CONTROLLER NEEDED?
TABLE 2
TABLE 3 MOUNTING CONFIGURATIONSMALE THREAD MALE PIPE PLUG FLANGE
BULKHEAD FITTING
1/8" NPT
1/4" NPT
3/8" NPT
1/2" NPT
3/4" NPT
2"
1-1/2"
1-1/4"
BULKHEAD
SPECIFY SIZE:
TABLE 4 LENGTH & OPERATING POINTAdditional levels are available. Please consult factory.
SPDT SLOSHSHIELD
L1
L2
L3*
L4
L5
L (Total) =
LENGTHSREQUIRED
LH =LH
L5
L (Total)
L1
SWITCHOPER.NO/NC
L4L2
L3
L4
L5
Refer to Switch Set-Up Criteria (Table 5)in order to determine lengths required.
*M5602
M5402
M8802
M8602
M8402
M6602
M4602
M4302
Full-Size FloatsSPST 60 WATTS SPDT 25 WATTSSPST 100 WATTS
STAINLESS STEEL
POLYPROPYLENE
BUNA-N
2"(50.8)
2.13" (53.9)
2"(50.8)
1.5" (38.1)
2"(50.8)
1.25" (31.75)
*Rated for hazardous locations.
For switches with bent stems,specify horizontal distance (LH).
Please specify lengths and switch operation inchart below, always starting with thebottom switch (L5).
FLOAT DESIGNAVAILABLE
STEM MATERIALSMODEL NO.
STAINLESS STEEL
BRASS
POLYPROPYLENE
POLYSULFONE
STAINLESS STEEL
BRASS
CPVC
STAINLESS STEEL
BRASS
For M5602, M5402, M8602, M8402, M4602, M4302L (Total) = L5 + 1-1/2" (38.1mm) Min.Distance from mounting fitting to first switch = 1-1/4" (31.7mm) Min.Minimum distance between floats: 2-1/2" (63.5mm)Minimum LH = 2-1/2" (63.5mm)
For M8802, M6602L (Total) = L5 + 2" (50.8mm) Min.Distance from mounting fitting to first switch = 1-3/4" (44.4mm) Min.Minimum distance between floats: 3" (76.2mm)
State your current ________ and voltage ________ requirements.
TABLE 5 SWITCH SET-UP CRITERIA
Max. Max.Model Temp. PSIG
M5602* 200˚C 200M5402 200˚C 200M4302 105˚C 150M4602 105˚C 150M6602 90˚C 100M8802* 105˚C 100M8602 105˚C 100M8402 105˚C 100
InstallationNC Operation:
SS Floats: Witness mark(round circle) down.
Plastic Floats: Magnets up.
NO Operation:SS Floats: Witness mark (round circle) up.Plastic Floats: Magnets down.
Above ratings are for resistive loads only.For inductive loads, maximum life will beachieved if appropriate arc suppressionis used.
Typical Current& Voltage Ratings
Watts
100
60
25
Voltage
240 AC120 AC120 DC24 DC
240 AC120 AC120 DC24 DC
240 AC120 AC120 DC24 DC
Current Amps
0.41.00.41.0
0.40.50.20.5
–0.28
–0.28
* NSF approved for use in food equipment.
* 4 levels maximum on model M8802
Madison Company • (203) 488-4477 • Fax (203) 481-5036 • E-mail: [email protected] • www.madisonco.com © Copyright Madison Co. – 6/08 LL-51
M Series Specification SheetFull-Size Multi-Point Liquid Level Switches
LL
INSTRUCTIONSComplete Process Conditions (Table 1). Select float design, stemmaterial and watt rating (Table 2). Select mounting configuration (Table 3). Provide required dimensions and switch operation (Table 4). Mail or fax with purchase order to Madison Company.
All measurements in parentheses are in millimeters.
TABLE 2
TABLE 3 MOUNTING CONFIGURATIONSMALE THREAD MALE PIPE PLUG FLANGE
BULKHEAD FITTING
1/8" NPT
1/4" NPT
3/8" NPT
1/2" NPT
3/4" NPT
2"
1-1/2"
1-1/4"
BULKHEAD
SPECIFY SIZE:
TABLE 4 LENGTH & OPERATING POINTAdditional levels are available. Please consult factory.
SLOSHSHIELD
L1
L2
L3*
L4
L (Total) =
LENGTHSREQUIRED
LH =LH
L4
L1
SWITCHOPER.NO/NC
L3L2
L3*
L4
L (Total)
Refer to Switch Set-Up Criteria (Table 5) in order to determinelengths required.
For switches with bent stems,specify horizontal distance (LH).
Please specify lengths and switch operation inchart below, always starting with thebottom switch (L4).
FLOAT DESIGNAVAILABLE
STEM MATERIALSMODEL NO.
For M5002, M5042, M8080, M8002, M8042, M4402, M4502
L (Total) = L4 + 1" (25.4mm) Min.
Distance from mounting fitting to first switch = 3/4" (19.05mm) Min.
Minimum distance between floats: 1-1/2" (38.1mm) / 1-3/4" (44.5mm) for M8080
Minimum LH = 1-1/2" (38.1mm) / NA for M8080
State your current ________ and voltage ________ requirements.
TABLE 5 SWITCH SET-UP CRITERIA
Max. Max.Model Temp. PSIG
M5002* 200°C 300M5042 200°C 300M4502 105°C 150M4402 105°C 150M8002* 105°C 100M8042 105°C 100M8080* 105°C 25
Installation
NC Operation:SS Floats: Witness mark (round circle) down.Plastic Floats: Magnets up.
NO Operation:SS Floats: Witness mark (round circle) up.Plastic Floats: Magnets down.
Above ratings are for resistive loads only.For inductive loads, maximum life will beachieved if appropriate arc suppressionis used.
Typical Current& Voltage Ratings
Watts
30
Voltage
240 AC120 AC120 DC24 DC
Current Amps
0.140.280.070.28
* NSF approved for use in food equipment.
* 3 levels maximum on model M8080
M5002
M5042
M8080
M8002
M8042
M4402
M4502
STAINLESS STEEL
BRASS
POLYPROPYLENE
POLYSULFONE
STAINLESS STEEL
BRASS
STAINLESS STEEL
BRASS
Miniature-Size Floats SPST 30 WATTS
STAINLESS STEEL
POLYPROPYLENE
BUNA-N
1.19"(30.2)
1.13" (28.7)
1"(25.4)
1" (25.4)
1"(25.4)
1" (25.4)
Madison Company • (203) 488-4477 • Fax (203) 481-5036 • E-mail: [email protected] • www.madisonco.comLL-52 © Copyright Madison Co. – 1/08
TABLE 1 PROCESS CONDITIONS
MAX. TEMP. MIN. TEMP.
MAX. PRESSURE SPECIFIC GRAVITY
FLUID
SPECIAL COND.
QUANTITY WIRE LENGTH24" (609.6mm) standard
TEMPERATURE SENSOR OPTION:
THERMOCOUPLE: TYPE J TYPE K TYPE T
THIN-FILM RTD: 100 OHM 1000 OHM
BIMETAL: CREEP ACTION SNAP ACTION THERMISTOR
TEMPERATURE RANGE
OTHER CONSIDERATIONS
CONTROLLER NEEDED?
M Series Specification SheetMiniature Multi-Point Liquid Level Switches
LL
© Copyright Madison Company – 4/09 CL-1
Model C3957 withStainless Steel Float
Madison Company offers a full line of standardmodels of continuous liquid level indicators withsensing ranges up to 96”. On the reverse side ofthis sheet, you will find a representative list of thesestandard models.
Our engineering staff can also provide customdesigns that are application specific to meetmaterial compatibility, length, resolution andmounting requirements. Use our C SeriesSpecification Sheet to define your requirements.
Our resolution options of 5mm, 10mm and 1”combine the accuracy and reliability of reed switchtechnology with a level indication interface that canmatch your need for continuous level monitoring atan affordable price.
Our 1” resolution model (C3975-XXXX) is offeredwith a field-repairable sensor strip. This allows forpermanent mounting of the level switch assemblywhile permitting in-field replacement of the flexiblesensor strip via a simple screw-in assembly. This isvery desirable where limited overhead space orpermanent tank closure are a consideration. This isoffered with a standard linear output or applicationspecific output.
• Continuous level indication
• Controllers available
• Various material choices, lengths andmounting configurations
• Wide selection of U.S. and European BSPP and BSPT fittings
• Configure online through our Product Configuratorand receive an instant quotation
Model C3975 withreplaceable flexible
sensor strip
ContinuousLevel Indicators
Madison Company(203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • E-mail: [email protected]
Madison EuropePhone + 31 (0) 548 659 034 • Fax + 31 (0) 548 659 010 • E-mail: [email protected]
www.madisonco.com
CL
* Replacement Sensing Strips(For Models C3975-XXXX)
Continuous Level Transducers
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.
PP = Polypropylene SS = Stainless Steel** All models are CE approved; refer to Approvals page in the Reference section for more information.† A wide selection of U.S. and European BSPP and BSPT fittings is available for all of these items.
CL-2 © Copyright Madison Company – 4/09
MODEL
080-003976-1000
080-003976-1004
080-003976-1003
080-003976-1007
080-003976-1006
SENSING LENGTH
16"
24"
32"
42"
48"
C Series Continuous Level Transducers
MODEL** RESOLUTIONFLOATMATL.
STEMMATL.
MAX.TEMP.(CELCIUS)
MAX.PSIG
FLOATSG
SENSINGLENGTH FITTING† OUTPUT
C3946-1002 10mm PP 316SS 85˚C 100 0.75 16" 2" Pipe Plug 4-20 mA
C3946-1007 10mm PP 316SS 85˚C 100 0.75 24" 2" Pipe Plug 4-20 mA
C3946-1018 10mm PP 316SS 85˚C 100 0.75 32" 2" Pipe Plug 4-20 mA
C3946-1019 10mm PP 316SS 85˚C 100 0.75 36" 2" Pipe Plug 4-20 mA
C3946-1020 10mm PP 316SS 85˚C 100 0.75 48" 2" Pipe Plug 4-20 mA
C3946-1000 10mm Buna-N 316SS 85˚C 150 0.45 40" 2" Pipe Plug 4-20 mA
C3946-1003 10mm Buna-N 316SS 85˚C 150 0.45 30" 2" Pipe Plug 4-20 mA
C3946-1006 10mm Buna-N 316SS 85˚C 150 0.45 76" 2" Pipe Plug 4-20 mA
C3946-1010 10mm Buna-N 316SS 85˚C 150 0.45 62" 1-1/2" Pipe Plug 4-20 mA
C3946-1011 10mm 316SS 316SS 85˚C 200 0.55 30" 2" Pipe Plug 4-20 mA
C3957-1000 5mm PP 316SS 85˚C 100 0.75 16" 2" Pipe Plug 4-20 mA
C3957-1016 5mm PP 316SS 85˚C 100 0.75 24" 2" Pipe Plug 4-20 mA
C3957-1017 5mm PP 316SS 85˚C 100 0.75 32" 2" Pipe Plug 4-20 mA
C3957-1007 5mm Buna-N 316SS 85˚C 150 0.45 36" 1/2" NPT 4-20 mA
C3957-1018 5mm PP 316SS 85˚C 100 0.75 42" 2" Pipe Plug 4-20 mA
C3957-1004 5mm 316SS 316SS 85˚C 200 0.55 48" 2" Pipe Plug 1-5 Volt
C3957-1001 5mm Buna-N 316SS 85˚C 150 0.45 16" 2" Pipe Plug 4-20 mA
C3957-1006 5mm 316SS 316SS 105˚C 200 0.55 8" 1/2" NPT Resistive
C3975-1000* 1" PP 316SS 85˚C 100 0.75 16" 1-1/2" Pipe Plug 4-20 mA
C3975-1004* 1" PP 316SS 105˚C 100 0.75 24" 2" Pipe Plug 220 Ohms/inch
C3975-1003* 1" PP 316SS 105˚C 100 0.75 32" 2" Pipe Plug 220 Ohms/inch
C3975-1007* 1" PP 316SS 105˚C 100 0.75 42" 2" Pipe Plug 220 Ohms/inch
C3975-1006* 1" PP 316SS 105˚C 100 0.75 48" 2" Pipe Plug 220 Ohms/inch
CL
In addition to the standard part numbers listed above, these Continuous Level Indicators can be custom configuredusing our online Product Configurator.
Visit www.madisonco.com for details.
Madison-Omni® Continuous Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/08 CL-3
PP = Polypropylene SS = Stainless Steel
All specifications are subject to change without notice.
C Series Continuous Level Transducers
MODEL RESOLUTION / TYPEFLOATMATL.
STEMMATL.
MAX.TEMP.(CELCIUS)
MAX.PSIG
FLOATSG
SENSINGLENGTH FITTING
C4048-1000 5mm vertical PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4048-1000S 5mm swan PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4048-1001 5mm vertical PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4048-1001S 5mm swan PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4048-1002 5mm vertical PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4048-1002S 5mm swan PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4048-1003 5mm vertical PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4048-1003S 5mm swan PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4048-1004 5mm vertical PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4048-1004S 5mm swan PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4048-1005 5mm vertical PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
C4048-1005S 5mm swan PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
C4049-1000 10mm vertical PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4049-1000S 10mm swan PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4049-1001 10mm vertical PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4049-1001S 10mm swan PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4049-1002 10mm vertical PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4049-1002S 10mm swan PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4049-1003 10mm vertical PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4049-1003S 10mm swan PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4049-1004 10mm vertical PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4049-1004S 10mm swan PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4049-1005 10mm vertical PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
C4049-1005S 10mm swan PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
C4047-1000 1" vertical PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4047-1000S 1" swan PP 316SS 70˚C 100 0.75 12" 2" Pipe Plug
C4047-1001 1" vertical PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4047-1001S 1" swan PP 316SS 70˚C 100 0.75 24" 2" Pipe Plug
C4047-1002 1" vertical PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4047-1002S 1" swan PP 316SS 70˚C 100 0.75 36" 2" Pipe Plug
C4047-1003 1" vertical PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4047-1003S 1" swan PP 316SS 70˚C 100 0.75 48" 2" Pipe Plug
C4047-1004 1" vertical PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4047-1004S 1" swan PP 316SS 70˚C 100 0.75 60" 2" Pipe Plug
C4047-1005 1" vertical PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
C4047-1005S 1" swan PP 316SS 70˚C 100 0.75 72" 2" Pipe Plug
CL
CL
C SeriesField-RepairableContinuous Level Switches
Features
• Field-repairable, watertight removable core
• Stainless steel or brass stem
• 3” minimum required above tank level
• Temperature sensing available
• Alarm and various output signals available
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 CL-5
C3945 & C3975ContinuousLevel Switches
When your application calls for a sealed tank, or the installation does not lend itself to easy removal,Madison Company’s C3945 and C3975 field-repairablecontinuous level switches should be considered.
The entire stem and face mount can be permanentlysealed to the vessel. Should replacement of the reed switches become necessary, unscrewing the top mount and removing the entire switch assembly can be accomplished without compromising the vessel’s interior environment.
The ability to easily remove the C3945 and C3975 from a sealed tank allows most repairs to be completed on-site.When compared to conventional liquid level switches, thisfield-repairable continuous level switch eliminates the need for tank depressurization and reduces the chance ofenvironmental contamination.
Removal and replacement offlexible sensor strip can beeasily accomplished on-site
CL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
CL-6 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Options
Resolution – 1”
Resistive Value – 220 ohms with 220 ohms per inch linear, standard
– 240-33 or 0-90 ohms also available
– Application-specific ohms per inch, engineered
Max Power – 1/8 Watt
Lengths – 12” to 96”Standard lengths: 16”, 24”, 32”, 36”, 42”, 48”Shorter and longer, engineered-specific
Materials – Stainless Steel or Brass stem and fitting,Polypropylene and Buna-N floats
Temperature Range – -40˚C to 105˚C (-40˚F to 221˚F)
Output – 220 ohms to 5.2 K ohms, standardApplication-specific ohms, engineered
Float Diameter – Buna-N: 1-1/4”; Polypropylene: 1-1/2”
Approval – All models carry CE approval. Model C3975 is also ABS approved. Other approvals areavailable, please consult factory.
1.92”(48.8)
ø1.25”(31.8)
Buna-NFloat
1.85”(47.0)
ø1.5”(38.1)
PolypropyleneFloat
2.10”(53.3)
ø2.05”(52.1)
StainlessSteel Float
Inside Mount Outside Mount ANSI Flange
Fitting Options: Representative samples at right
• 3/4”, 1” or 1-1/2” NPT inside mount
• 1-1/2” or 2” NPT outside mount*
• 2”, 3” or 4” ANSI flange
• Other mounting options available
• 4-20 mA output – 2-wire• 1-5 VDC output – 3-wire• Additional alarm levels• Temperature sensing• Replacement sensor assembly• Elbow extension for fitting available• Controller
*1-1/2” NPT outside mount not available with stainless float
SensingRange
L Total
0.25” (7.1)Deadband*
2.63” (66.8)Deadband*
CL
C SeriesContinuous Level Transducer
Features
• Flexibility for varied fluid environments
• Suitable for any tank application
• Provides precise, uninterrupted readout with 5mm or 10mm resolution
• Various output signals available (4-20 mA, 1-5 DC, resistive, etc.)
• Ideal for: – Remote sensing in tanks with restricted or limited access– Precise liquid level monitoring in a series of tanks in
mixing operations– Central monitoring of liquid level in remote multiple tanks– Any tank application where the exact liquid level has to be
known at any time
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 CL-7
Model C3957 withStainless Steel Float
Madison’s continuous level transducers aredesigned for vertical mounting in a tank. Reedswitches are evenly spaced over the operationrange to achieve the desired resolution. A singlemagnet-containing float travels the length of thesensing range. The reed switches aremagnetically actuated as the float moves with theliquid level. DC power is applied to the switch,and the output signal can then be routed toprogrammable controllers, microprocessors orother readout devices.
Model C3946 is a 10mm resolution continuouslevel float switch with a stainless steel or brassstem and available with either a polypropylene,Buna-N or stainless steel float.
Model C3957 is a 5mm resolution continuouslevel float switch with a stainless steel or brassstem and is available with either a stainless steel,polypropylene or Buna-N float.
Both models are suitable for petroleum-basedliquid applications, in addition to many otherliquids with low- to mid-range viscosity.
Model C3946 withBuna-N Float
Model C3946 withPolypropylene
Float
CL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
CL-8 © Copyright Madison Company – 5/05
All specifications are subject to change without notice.
Inside Mount Outside Mount ANSI Flange
Fitting Options: Representative samples at right
• 1/2”, 3/4”, 1” or 1-1/2” NPT inside mount
• 1-1/2” or 2” NPT outside mount*
• 2”, 3” or 4” ANSI flange
• Other mounting options available
• Temperature Sensing
• High/Low Set Point Alarms
Resolution – 5 or 10mm
Signal Output – 1/10 Watt resistive, 100 ohms per 5mm3-wire: 10-30 VDC, 1-5 V output2-wire: 10-30 VDC, 4-20 mA output
Wiring Details – 2-wire: Red - positiveBlack - negative
3-wire: Red - positiveBlack - negativeWhite - signal out
Switch Materials – 316 SS or brass stem and
Buna-N float (float dia. 1.25”) orStainless float (float dia. 2.05”) orPolypropylene float (FDA approved) (float dia. 1.5”) Note: all stem diameters are 0.5” OD
Sensing Length – 6” to 96”Standard lengths: 16”, 24”, 32”, 36”, 42”, 48”Note: overall switch length will be longer, to allow float travel over the sensing range
Operating Temp. – -40˚C to 105˚C (-40˚F to 221˚F), Resistive output– -40˚C to 85˚C (-40˚F to 185˚F),
4-20 mA, 1-5 V output
Approval – All models carry CE approval. Model C3975 is also ABS approved. Other approvals areavailable, please consult factory.
.75” (19.1)Deadband
L Total
SensingRange
1.88” (47.8)Deadband
Buna-NFloat
PolypropyleneFloat
StainlessSteel Float
*1-1/2” NPT outside mount not available with stainless float
Options
1.92”(48.8)
ø1.25”(31.8)
1.85”(47.0)
ø1.5”(38.1)
2.10”(53.3)
ø2.05”(52.1)
CL
Sensing Range: ___________________________________
Signal Output: 3-wire, 1-5 VDC
2-wire, 4-20 mA
Resistive
Controller (specify type): ____________________________
Madison Company can engineer field-repairable continuous level transducers to meet your application needs.Please provide the information requested below so that our Engineering Department can determine theappropriate design for your application.
PART
#M
ATER
IALS
TOTA
L LE
NG
TH
NO
TES
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Madison Part Number:
C3945 Non-Linear C3975 Linear
MO
UN
TIN
G
Stem and fitting are Stainless Steel or Brass. Stem dia. is 0.5”.Stem: Stainless Steel BrassCollar is stainless steel. Float is Buna-N or polypropylene.Float: Buna-N Polypropylene
REQ
UIR
EMEN
TS
Sensing Range: _________________
Plus Top Deadband: 0.25” (C3975) or 1” (C3945)
Plus Bottom Deadband: 2.63” (C3975) or 1” (C3945)
Equals L Total: _________________
Sensor solutions for today and the future™
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
* DEADBAND: EXTRA STEMLENGTH TO ALLOW FORPROPER FLOAT TRAVELOVER SENSING RANGE
LTOTAL
LTOTAL
LTOTAL
Pipe Plug:Outside Mount
1-1/2” 2”
Flange: Outside Mount
2” 3” 4”
NPT: Inside Mount
3/4” 1”
1-1/2”
Other mountingconfiguration(please describe below)
Buna-NFloat
PolypropyleneFloat
StainlessSteel Float
1.92”(48.8)
ø1.25”(31.8)
1.85”(47.0)
ø1.5”(38.1)
ø2.05”(52.1)
2.10”(53.3)
SensingRange
L Total
0.25” (7.1)Deadband*
2.63” (66.8)Deadband*
OPT
ION
S
Temperature sensor (Type) _________________
High/low set point alarms
© Copyright Madison Company – 10/05 CL-9
C Series Specification SheetField-Repairable 1” Continuous Level Transducer
CL
Sensing Range (6” to 96” standard): _____________________
Resolution: 5mm (C3957) 10mm (C3946)
Signal Output: 3-wire – 1-5 VDC
2-wire – 4-20 mA
2-wire (resistive) – 1/10 W rating,100 ohms per 5mm of indication
Controller (specify type): ______________________________
Madison Company can engineer continuous level transducers to meet your application needs. Pleaseprovide the information requested below so that our Engineering Department can determine the appropriatedesign for your application.
MAT
ERIA
LSTO
TAL
LEN
GTH
NO
TES
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
OPT
ION
S
Stem: 316 Stainless Steel BrassStem diameter is 0.5”.
Float: Polypropylene Stainless Steel* Buna-N
*1-1/2” NPT outside mount not available with stainless float
REQ
UIR
EMEN
TS
L Total: _________________
Sensor solutions for today and the future™
C Series Specification Sheet5 and 10 mm Continuous Level Transducers
* DEADBAND: EXTRA STEMLENGTH TO ALLOW FORPROPER FLOAT TRAVELOVER SENSING RANGE
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected] © Copyright Madison Company – 10/05
Temperature sensor (Type) _________________
High/low set point alarms
Buna-NFloat
PolypropyleneFloat
StainlessSteel Float
MO
UN
TIN
G
Pipe Plug:Outside Mount
1-1/2” 2”
Flange: Outside Mount
2” 3” 4”
NPT: Inside Mount
1/2” 3/4”
1” 1-1/2”
Other mountingconfiguration(please describe below)
1.92”(48.8)
ø1.25”(31.8)
1.85”(47.0)
ø1.5”(38.1)
ø2.05”(52.1)
2.10”(53.3)
1.88” (47.8)Deadband
SensingRange
L Total
.75” (19.1)Deadband
LTOTAL
LTOTAL
LTOTAL
CL
C SeriesMadison-Omni® Sensors
Features
• Two switching points (e.g. high and low alarms)
• Hysteresis selectable in magnitudeand direction
• 4-20 mA analog output
• Graphical LCD display (increasedtemperature range, illuminated, unitsin the display, includes super-brightsignaling LED)
• Programming ring; lock in customsettings by inverting or removing ring
• Dialog messages in the display
• Stainless steel housing
• Mineral glass (tempered, scratch- andbreak-proof) for covering the display
• M 12x1 connector system
• System mounting to all Madisonprimary C-Series sensors
• Compact dimensions
• IP 67
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.comMadison Europe • Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • [email protected]
© Copyright Madison Company – 5/08 CL-11
Madison Company introduces a self-contained, compact alarmdisplay as an integral part of its continuous liquid level switch family.The Madison-Omni is a user-programmable device that has a simpleand secure set of options for level indication, unit of measure andseveral other variables. The LCD display is easy to read, and aseparate red LED light is a visual alarm when the programmedparameters are outside the set ranges. The program ring can beremoved or left on the unit in a reverse manner to secure the settings.
Switch point indications can be set directly on site using Madison-Omni Sensors for upper and lower set point values. Using the display,these settings can also be programmed without the Madison-Omniinstalled in the tank. The current values at the measuring point arealways visible and all the important parameters can be called up atthe point of measurement, saving time during installation, setup andtroubleshooting. The analog current signal can be evaluated over longdistances and the momentary value made available remotely.Madison-Omni Sensors are configured to your specifications and areready for use without any programming. If you need to changeparameters, use the programming ring directly on the sensor withoutany additional tools.
CL
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
CL-12 © Copyright Madison Company – 1/09
Supply Voltage – 18-30 VDC
Power Consumption – 0.5 Watts
Measurement Range – Varies according to specific model
Accuracy – 1% of full scale
Reproducibility – 0.1% of full scale
Dynamic Response – Measurement cycle: 32 ms; Display cycle: 0.5 s
Operating Temperature – -20˚C to 70˚C (-4˚F to 158˚F)
Storage Temperature – -20˚C to 80˚C (-4˚F to 176˚F)
Signal Output – 4-20 mA, 2-10 V through 500 Ohm termination resistance
Switching Points S1 & S2 – PNP or NPN selectable; 300 mA load in sum, maximum; programmable asminimum or maximum value; short-circuit and reverse-polarity proof
Hysteresis – Adjustable; position of hysteresis depends on minimum or maximum
Display – Graphical LCD display, extended temperature range -20˚C to 70˚C; 32x16 pixels; back-lit; showsvalue and units; LED signaling lamp with simultaneous message in display
Connection – At locking plug M 12x1, 5-pole*
Protection Class – IP67
Material – Varies according to specific model
Mounting – Varies according to specific model
Approval –
All specifications are subject to change without notice.
M12 x 1
2.09" (53)
≈ 1.
10" (
28)
ø1.3
8" (3
5)
ø1.7
7" (4
5)
CL
Wherever Madison Company’s C-Series continuous level switches have been used, a direct replacementwith the Madison-Omni switch can be made. Give us the previously used part number and we will provideyou with a new Madison-Omni part number.
Where the Madison C-Series switch with a separate display was used, with minimal effort you can now usethe Madison-Omni as a combined sensor with integrated display.
Applications
* Madison-Omni® Sensor Accessories (sold separately)029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug
029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
M SeriesSingle-Point Probe ConductivitySensor for Food Applications
Features
• Small size
• Low cost
• Sensitivity-adjustable controller
• No moving parts
• Safe operation
• Made entirely of food-grade materials
• Can be used for multiple level indication
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 CD-1
M3850
The M3850 is a small, low-cost sensor designed forfood applications in metal-walled tanks or vessels.Installation is simple, and they can be wired in phaseso that multiple level points can be detected. Allmaterials are food-grade, and the contours of theinsulator shell meet NSF requirements for cleaning.
While a conductivity switch and a float-type switchperform the same functions, the advantage of nomoving parts is that the conductivity switch can beused in several environments that would cause afloat to stick or to not operate at all. The probe ismounted with an insulator shell for sensing in suchliquids. With no moving parts, switch operation of theM3850 is not interrupted.
Only an extremely small amount of current isnecessary for the unit to perform. As with anydevice, a properly installed and grounded systemposes no electrical hazard.
Madison supplies a basic controller with the M3850that will satisfy a broad range of applications.Because conductivity varies widely among liquids,the controller is adjustable for sensitivity in differentliquids. Consult factory for details on a specific liquid.
CD
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
CD-2 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
01.00"(25.4)
0.75"(19.05)
0.59"(14.99)
1.63"(41.4)
0.84"(21.3)
ConductivityProbe
NutWasher
Tank Wall
Insulator
Chamfer45° x 0.080" (2.03)
Upper Probe
Lower Probe
CommonProbe
1
4 NC
3 NO
7
2
Switched Contacts
120 VAC Input
5 6 8
• 120 VAC is connected between pins 2 and 7
• Wire the Common Probe to pin 5• Wire the Lower Probe to pin 6• Wire the Upper Probe to pin 8
Pins 1-3 and 1-4 are isolated switchcontacts to switch power to a valve or pump.
For single level control, connect probe to pin 8 and use pin 5 as the return.
R2 Conductivity Configuration
M3850
105˚C (221˚F)
30
Bulkhead 1/2-13
Model No.
Max. Temp.
Max. PSIG
Available Mounting
R2
3 max., High, Low, Common
12 VAC
Adj. to 100,000 Ohms
120 VAC 50/60 Hz
5 Amps res. @ 240 VAC, form SPDT
Socket mount; socket is DINrail-mountable
Model No.
Sensing Inputs
Sensing Voltage
Sensing Resistance
Input
Output
Mounting
M3850
R2
Sensing Head
Controller
(1-3 or 1-4)
5A @ 220 VAC10A @120 VAC10A @ 30 VDC
Output Contact Rating
PUMP
INPUTPOWER
R2
8 7
643
12
LOW LEVEL
HIGH LEVEL
COMMON
M3850 (X3)
5
NOTE: DRAWING FOR PUMP UP OPERATION.TO CHANGE TO PUMP DOWN, WIRE PUMPTO TERMINAL 3 ON CONTROLLER INSTEADOF TERMINAL 4.
Three M3850 units in phase
CD
M SeriesConductivity Switch
Features
• Sensitivity-adjustable controller
• No moving parts
• Safe operation
• Controls up to two levels with controller
• NPT fitting (bulkhead or flange-type fitting available)
• One to three electrodes, depending on tankmaterial and number of functions required
• Electrodes are 1/8” diameter 316 Stainless Steel; all wetted materials are food-grade
• Standard 24” electrode can be cut by end user toshorter length; two 24” extensions can be added fora maximum recommended length of 72”
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 CD-3
M3784
Madison Company’s conductivity switch is the current choice forheavy-bodied or semisolid liquids.
Madison supplies a basic controller with the M3784 that will satisfy abroad range of applications. Because the conductivity varies widelyamong liquids, the controller is adjustable for sensitivity in differentliquids. Consult factory for details on specific liquids.
While a conductivity switch and a float-type switch provide the samefunctions, the advantage of no moving parts is that the conductivityswitch can be used in several environments that would cause a floatto stick or to not operate at all. These would include semisolid liquidslike food industry and industrial slurries or heavy-bodied liquids likewastewater. With no moving parts, switch operation of the M3784 isnot interrupted.
Only an extremely small amount of current is necessary for the unit toperform. As with any device, a properly installed and grounded systemposes no electrical hazard.
Model No.
M3784-12M3784-110M3784-220
M3784-2
Voltage
12 AC110 AC220 AC
no controller
For installation instructions,please visit
www.madisonco.com
CD
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
CD-4 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Sensing Head
Electrodes
Materials
Mounting
Pressure
Temperature
Other
24” length, standard72” length, maximum (with two extensions)May be cut to custom length
316 Stainless Steel electrodesPolypropylene all food-grade materials
1” NPT, standardBulkhead or snap-in flange optional
30 PSIG, maximum
100˚C, maximum (212˚F)
Integral junction box with IP68 (NEMA 6)protection 10’ cable for attaching sensinghead to controller
Controller
Model No.
Sensing Inputs
Sensing Voltage
Sensing Resistance
Input
Output
Mounting
R2-120 (Refer to Accessories sectionfor more information)
3 maximum (High, Low, Common)
12 VAC
Adjustable to 100,000 Ohms
120 VAC 50/60 Hz
Contact rating 5 Amps resistive @ 240 VAC, form SPDT
Socket mount, socket is DIN rail-mountable
Options– Electrode extensions, two each, 24” length, with coupling nuts and electrode spreader– Single electrode fitting with 24” electrode
Upper Probe
Lower Probe
CommonProbe
1
4 NC
3 NO
7
2
Switched Contacts
120 VAC Input
5 6 8
• 120 VAC is connected between pins 2 and 7
• Wire the Common Probe to pin 5• Wire the Lower Probe to pin 6• Wire the Upper Probe to pin 8
Pins 1-3 and 1-4 are isolated switchcontacts to switch power to a valve or pump.
For single level control, connect probe to pin 8 and use pin 5 as the return.
R2 Conductivity Configuration
R2
(1-3 or 1-4)
5A @ 220 VAC10A @120 VAC10A @ 30 VDC
Output Contact Rating
Conductivity Switch KitM3784-110MK
CD
Madison Company can engineer custom-designed conductivity switches to meet your application needs.Please provide the information requested below so that our Engineering Department can determine theappropriate design for your application.
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Sensor solutions for today and the future™
M Series Specification SheetCustom-Designed Conductivity Switches
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
© Copyright Madison Company – 10/05 CD-5
Male Thread: 1/4” NPT – One probe max. (plastic only)
3/8” NPT – One probe max. (plastic or metal)
1/2” NPT – Two probe max. (plastic or metal)
3/4” NPT – Three probe max. (plastic or metal)
1” NPT – Four probe max. (plastic or metal)
Flange: Specify size: (plastic or metal)
PRO
CESS
ING
CO
ND
ITIO
NS
CON
NEC
TIO
NS
Maximum Temperature:
Minimum Temperature:
Maximum Pressure:
Fluid:
Special Conditions:
Quantity:
Controller (specify type):
ADD
ITIO
NAL
REQ
UIR
EMEN
TS
MO
UN
TIN
G C
ON
FIG
UR
ATIO
NS
Standard insulated stainless steel screw lock terminal
Wire length: Gauge:
Cable (specify):
Other (specify):
LEN
GTH
S
Required Lengths (refer to diagram at right):
L1
L2
L3
L4
L1
L2
L3
L4
Please use the space below to list any additional requirements, such
as junction box, etc.
CD
CD
PR SeriesHydrostatic Pressure Level Sensors
Submersiblehydrostaticpressure sensors;tube filter shownat left (P/N 099-00088,sold separately)
The MAD4500 and MAD4510 submersible pressure sensorsare approved to UL/cUL913 (CSA 157) Class I Div 1,Groups C and D for use in intrinsically safe areas with an approved barrier. For pressure ranges from 0-2.5 PSIGto 0-100 PSIG that require a wide range of mediacompatibility, the submersible series is an excellent solutionfor level monitoring in both indoor and outdoor applications.
With their rugged construction and materials, these pressure sensors offer a wide range of compatibility. Typicalapplications include: ground water level depth measurement;earthen and concrete dams; liquid tanks; gasoline and dieselfuel tanks; irrigation; and waste water canals.
Madison’s hydrostatic line of liquid leve l sensors utilizes aunique diaphragm technology and solid state design thatprovides high accuracy, reliability and versatility in variousvessel configurations with liquid specific gravity pressure up to 100 PSIG. Should these standard models not matchyour application, our PR Series Specification Worksheet can be completed and submitted for engineering evaluationand quotation.
Features
• High-strength stainless steel construction
• One-piece construction – no internal O-ring
• Wide operating temperature range
• Ranges up to 100 PSI with 4-20 mA or 0-5 V output; tank depths of 3’ to 250’
• Unparalleled price and performance
• Rugged design is suitable for harsh environments
• Compatible with a wide range of liquids
• EMI/RFI protection
• Easy to install
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/09 PS-1
PS
MAD4500 & MAD4510 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PS-2 © Copyright Madison Company – 9/09
Output 4-20 mA 1-5 VDCExcitation 10-28 VDC 10-28 VDC
Output Impedance > 10k Ohms < 100 Ohms, nominal
Current Consumption 20 mA, typical < 10 mA
Bandwidth (-3 dB) DC to 250 Hz DC to 1 kHz
Output Noise N/A < 2 mV RMS
Zero Offset < ±1% of FS < ±1% of FS
Span Tolerance < ±2% of FS < ±1.5% of FS
Output Load 0-800 Ohms @ 10-28 VDC 10k Ohms, min.
Reverse Polarity Protection Yes Yes
Jacketed cable,customer specified length,0.25” max. dia.
Nose cone(optional)
0.88” (22.4)
4.78” (121.4)
Jacketed cable,customer specified length,0.25” max. dia.
Nose cone(optional)
1.00” (25.4)
5.62” (142.7)
M
MAD4500 MAD4510
MAD4510 L 00005 P 4 X 1 000
Series Type
Configuration InterfaceL = Cone
Pressure RangeInsert pressure range from chart
Pressure UnitH= Inches H20P = PSI
Outputs3 = 1-5 VDC4 = 4-20 mA
ElectricalX = Optional Length (see Options below)
Wetted Materials1 = 316L, 304, Nickel Plated Brass, Hytrel
Options: Cable Lengths:003 = 100 Ft. (30.5m) Special Order050 = 150 Ft. (45.7m) Special Order065 = 50 Ft. (15.2m) Standard Length074 = 25 Ft. (7.6m) Standard Length
Note: Sensors are vented to atmosphere through surface end of cables.In high-humidity areas, a Hydrophobic Filter for the end of the vent tube (P/N 099-P00088) is recommended.
All specifications are subject to change without notice.
Intrinsically safe installations require approved barriers. Refer to the PR Seriesarea of the Reference section on www.madisonco.com for further details.
Performance @ 25˚C (77˚F):Accuracy* – < ± 0.25% BFSLStability (1 year) – ±0.25% FS, typicalOver-Range Protection – 2X Rated PressureBurst Pressure – 5X or 1,250 PSI (whichever is less)Pressure Cycles – > 50 Million* Accuracy includes non-linearity, hysteresis & non-repeatability
Environmental:Operating Temperature – -40˚F to 185˚F (-40˚C to 85˚C)Storage Temperature – -40˚F to 212˚F (-40˚C to 100˚C)Compensated Range – 30˚F to 130˚F (0˚C to 55˚C)TC Zero – < ±1.5% of FSTC Span – < ±1.5% of FSShock – 100G, 11 msec, 1/2 sineVibration – 10G peak, 20 to 2000 HzEMI/RFI Protection – YesRating – IP-68Cable Length (recommended max.) – 1-5 V < 35’; 4-20 mA, 500’
Electrical:PS
Pressure Ranges:MAD4500
Gage PSIG BAR Pressure Range Code
0-100 6.89 00100
0-50 3.45 00050
0-30 2.07 00030
0-20 1.38 00020
MAD4510
Gage PSIG BAR Pressure Range Code
0-15 1.03 00015
0-10 0.69 00010
0-7.5 0.52 00208**
0-5 0.35 00005
0-2.5 0.17 00069
0-1† 0.068 00001
Typical ranges. All ranges between 0-15 PSI and 0-100 PSI are available. Please consult factory.** Must be ordered in inches of H2O.† Only available with 1-5 VDC output.
PR SeriesHydrostatic Pressure LevelSensors for Turbulent Tanks
MAD4520-x hydrostatic pressure level sensorfor turbulent tanks
The MAD4520 Flush Submersible Series is thelatest addition to Madison’s line of hydrostaticpressure level sensors. It is designed formonitoring viscous material and/or turbulentconditions within a vessel. This cost-effectivesensor is approved to UL/cUL913 Class 1Division 1 IS, Groups C and D, with anapproved barrier. There are four pressureranges available, and the cage design allowsfor proper media flow while keeping the sensorat the bottom of the vessel or well.
The 316L and PVDF construction will withstandthe toughest environments. The MAD4520 isideal for sewage lift stations, food tanks andviscous media applications. Other typical usesinclude: grease and lubrication tanks; drillingmud pits; vegetable and animal oil tanks; andstorm and industrial holding tanks.
Features
• Compatible with a wide range of chemicals
• Suitable for waste, salt, brackish or fresh water systems and a wide range of chemicals
• EMI/RFI protection
• Reverse polarity protection
• Compact, non-clogging design
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 11/08 PS-3
PS
MAD4520 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PS-4 © Copyright Madison Company – 11/08
All specifications are subject to change without notice.
Performance @ 25˚C (77˚F):Accuracy* – < ±0.25% BFSLStability (1 year) – ±0.25% of FS, typicalOver-Range Protection – 2X rated pressureBurst Pressure – 5X or 1,250 PSI (whichever is less)Pressure Cycles – > 50 Million* Accuracy includes non-linearity, hysteresis and non-repeatability
Environmental:Operating Temperature – -40˚F to 185˚F (-40˚C to 85˚C)Storage Temperature – -40˚F to 212˚F (-40˚C to 100˚C)Temperature Compensated Range – 30˚F to 130˚F (0˚C to 55˚C)TC Zero – < ±1.5% of FSTC Span – < ±1.5% of FSShock – 100G, 11 msec, 1/2 sineVibration – 10G peak, 20 to 2000 HzEMI/RFI Protection – YesRating – IP-68Wetted Materials – Kynar and 316L stainless steelCable – PVDF jacketed
Electrical:Output – 4-20 mAExcitation – 10-28 VDCOutput Impedence – > 10k OhmsCurrent Consumption – 20 mA, typicalBandwidth – (-3 dB): DC to 250 HzZero Offset – < ±1% of FSSpan Tolerance – ±2% of FSOutput Load – 0-800 Ohms @ 10-28 VDCReverse Polarity Protection – YesLightning and Surge Protection – Yes
Approvals:UL and cUL913 listed, Class 1 Div 1 IS, Groups C and D with approved barrier
Pressure Ranges:0-150-100-7.5**0-5** Must be ordered in inches of H2O.Note: All ranges between 0-100 PSI are available. Please consult factory for specific needs.
Intrinsically safe installations require approvedbarriers. Refer to the PR Series area of the Reference section onwww.madisonco.com for further details.
Jacketed cable,customer-specified length,0.25” max. OD
Ø 1.00”(25.4)
Ø 3.00”(76.2)
5.54”(140.7)
2.25”(57.2)
† Wiring: 24 AWG, 4-conductorKynar (PVDF-jacketed) cable withdrain wire and breather tube;Standard lengths: 25’, 50’ and 75’
†
PS
PR SeriesMadison-Omni® Pressure Sensors
Madison-Omni-P and Omni-P1pressure sensors with integrated
programmable display
The Madison-Omni-P and Omni-P1 pressure sensormodels offer the same standard Madison-Omniprogrammable display as found on our level, ultrasonic andtemperature Madison-Omni switch models.
These pressure sensors consist of a primary sensor and the integrated signal processing electronics. Theprimary sensor is available in two different technologiesand ranges.
The Omni-P features a stainless steel diaphragm that transmits pressure data via an oil-filled cavity onto a mono-silicone substrate, utilizing anaccommodated piezo-resistive measuring bridge andthin-film poly-silicone technology. With a flush membrane,this sensor is suitable for applications with sticky fluid(such as glue components) or other critical liquids.
The Omni-P1 features an economical monolithic ceramicmeasuring cell with an accommodated resistive bridgeand thick-film technology. The integrated signalprocessing microcontroller evaluates the signal andoperates an analog output beside the display. Since thecomplete upper part of the housing can be rotated, thecable connection can be easily aligned as needed.
Features
• Analog output, two switching outputs
• Clear, easy-to-read backlit LCD display
• Changeable display units
• Designed for industrial applications
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 PS-5
PS
Madison-Omni-P & Omni-P1 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PS-6 © Copyright Madison Company – 1/09
All specifications are subject to change without notice.
Madison-Omni-P Madison-Omni-P1
Relative PressureRanges
Range Overload Range Burst
PSIG BAR PSIG BAR PSIG BAR PSIG BAR
0-14.50-36.30-87.0
0-145.00-362.60-870.2
0-1450.40-3626.00-5801.5
0-10-2.50-6
0-100-250-60
0-1000-2500-400
58.0145.0348.1580.2
1450.43480.95801.58702.38702.3
4102440100240400600600
0-14.50-29.00-72.50-87.00-290.10-725.20-1450.40-2900.8*0-5801.5*
0-10-20-50-100-200-500-1000-200*0-400*
58.087.0217.6580.2870.22175.64061.15801.515229.0
46
154060
150280400
1050
Options – Additional measurement ranges – Absolute pressure metering (low limit 10 mbar abs.)
* For gas applications, by request only
Accuracy ±1% v. FS, above 60˚C 0.02% / ˚C ±1% FS; 0.05% / ˚C below 0˚C and above 60˚C
Reproductability ±0.5% FS ±0.1% FS
Dynamic Measurement and output cycle 32 ms; display cycle 0.5 sec.
Operating Temp. -4˚F to 158˚F (-20˚C to 70˚C); 248˚F (120˚C) max. with swan neck
Storage Temp. -4˚F to 176˚F (-20˚C to 80˚C)
Supply Voltage 18-30 VDC
Power Consumption < 1 W
Analog Output 4(0)-20mA, 2(0)-10 V via resistor of 500 Ohm to GND (impedance of receiver > 100 kOhm)
Switching Outputs (S1 and S2)
PNP or NPN (push-pull), programmable as minimum- or maximum-switchMax. 300 mA output current (sum of both outputs), short-circuit proof, polarity safe
Hysteresis Adjustable, direction dependent on setting min. or max.
Display Graphical LCD display with extended temperature range -4˚F to 158˚F (-20˚C to 70˚C), 32x16 pixels, backlitLED-indicator flashing with additional message on display
Connection Process connection is only available with parallel threads (not NPT) and at locking plugs M12x1, 5 pole
Protection Class IP67
Materials – Media Contact Stainless steel 1.4301 Stainless steel 1.4571, ceramic Al2O3, Viton
Materials – Electronic Housing
Stainless steel 1.4305 (housing), hardened mineral glass, POM (programming ring), cobalt-samarium (magnet)
ø1.
77”
(45)
2.76” (70)
ø1.
38”
(35
)
0.55” (14)
G1/2A
SW 2727 AF
Locking plugs M12x1, 5-pole (accessory)*
5.51” (140)
An optional swan neck betweenthe electronic head and thesensor offers easy adjustmentand readout. This optionadditionally ensures the thermaldecoupling of both units.
18 to 30 VDC
4(0)-20 mA
OmniSensor
white
brown
gray
black
bluez
z
Z = load
1
2
3
4
5
z
or NPNExample: PNP
0 V
S1
S2
Terminal Assignment
Before carrying out the electrical installation,make sure that the supply voltage correspondsto the data provided. The switching outputs canbe connected as NPN or PNP without anyhardware or software settings (push-pull driver).A shielded cable (< 30m) and supply lines (< 10m) are recommended.
PS
* Madison-Omni® Sensor Accessories (sold separately)029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug
029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
PR SeriesMadison-Omni® Differential Pressure Transmitter
Madison-Omni-DP1 differentialpressure transmitter with integrated
programmable display
The Madison-Omni-DP1 is a differential pressuretransmitter that incorporates a programmable display. Thisis the same display that is featured on our Madison-Omnicontinuous level switches, ultrasonic sensors andtemperature sensors.
The Madison-Omni-DP1 has two separate ceramic sensorsembedded in a thick-film technology. The bridge signals aretemperature compensated. These PSIG measurements arecompaired and processed as a differential pressure outputsignal. The wetted materials are stainless steel, Al2O3
ceramic and Viton O-rings, making this model suitable formost liquid applications.
Features
• Suitable for use in most liquid applications
• Can also be used for high differential pressures
• High-quality materials offer high chemical resistance
• Display head can be turned for alignment after installation
• Analog output, frequency output, switching outputs
• Clear, easy-to-read backlit LCD display
• Changeable display units
• Designed for industrial applications
• Small and compact
• Quick and easy installation
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 PS-7
PS
Relative Pressure Operating Ranges / Overload Limits / Burst Pressure:
Differential Pressure Range: Customer-specified (min.: 10% of operating range; max.: operating range)Accuracy – ± 1% FSDOperating Temperature – 32˚F to 158˚F (0˚C to 70˚C); 185˚F (85˚C) max. with swan neckStorage Temperature – -4˚F to 176˚F (-20˚C to 80˚C)Supply Voltage – 18-30 VDCPower Consumption – < 1 WSwitching Values (S1 and S2) – PNP or NPN selectable; 300 mA load in sum max.; programmable as min.
or max. value; short-circuit proof; reverse-polarity proofHysteresis – Adjustable; position of hysteresis depends on min. or max.Display – Graphical back-lit LCD display with extended temperature range (-4˚F to 158˚F / -20˚C to 70˚C);
32x16 pixels; shows value and units; LED signaling lamp with simultaneous message in displayConnection – At locking plug M12x1, 5-pole*Protection Class – IP67Materials: Medium Contact – Stainless steel 1.4571, Viton, Ceramic Al2O3
Materials: Electronic Housing – Stainless steel 1.4305 (housing); tempered mineral glass (glass); cobalt samarium (magnet); POM (ring)
Madison-Omni-DP1 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PS-8 © Copyright Madison Company – 1/09
All specifications are subject to change without notice.
ø1.77” (45)
3.98
” (1
01)
2.09
” (5
3)
0.79
” (2
0)
Locking plugs M12x1, 5-pole (accessory)*
G 1
/80.83”
(21)
1.97” (50)
1.97
” (5
0)
5.51” (140)
An optional swan neck betweenthe electronic head and thesensor offers easy adjustmentand readout. This optionadditionally ensures the thermaldecoupling of both units.
18 to 30 VDC
4(0)-20 mA
OmniSensor
white
brown
gray
black
bluez
z
Z = load
1
2
3
4
5
z
or NPNExample: PNP
0 V
S1
S2
Terminal Assignment
The switch points are changing to PNP or NPN,depending on your interface, automatically.
Range Overload Burst
PSIG BAR PSIG BAR PSIG BAR
0-14.50-29.00-72.50-87.00-290.10-725.20-1450.40-2900.8
0-10-20-50-100-200-500-1000-200
43.587.0
217.6435.1870.2
2175.62900.84061.1
36
153060
150200400
58.0116.0290.1580.21015.32610.75076.38702.3
48204070180350600
PS
* Madison-Omni® Sensor Accessories (sold separately)029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
Madison Company can engineer hydrostatic pressure sensor designs for liquid level applications. To request this, your specific requirements must be defined below to help us determine both the technical andeconomic requirements for your application.
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
ENVI
RO
NM
ENT
ELEC
TRIC
AL
DES
IGN
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Application: Indoor Outdoor Mobile Hazardous Location Other:
Feet to PSI: (1 ft. of water = 12” H2O = 0.4335 PSI; multiply 0.4335 by the span to be measured within your vessel)
PSI Range: 0-100 0-50 0-30 0-20 0-15 0-10 0-7.5 0-5 0-2.5 Other:
Pressure Fitting: 1/4” NPT Male 1/8” NPT Male 1/2” NPT Male 1/4” NPT Female 1/8” NPT Female
7/16-20 UNF Male 7/16-20 UNF Female 9/16-18 UNF Male 1/4” BSP Male
F250C Female Autoclave
Pressure Range: Type: PSIG PSIS Bar Inches H2O kg/cm2
Vibration / Shock: Low High Humidity: Low High Accuracy:
Media:
Ambient Temperature – MIN: MAX: Media Temperature – MIN: MAX:
Submersible Transducer? Yes – Cable Length: Type: Jacket: Hytrel Kynar Other:
Turbulent Media? Yes No If yes, added weight required for stability:
Wetted Material: 17/4 PH 316 SS 304SS Inconel 718 Titanium Hastaloy Plated Brass
Other:
Agency Approvals (i.e. UL, NSF):
Output: 0-50 mV 0.5-4.5 VDC 1-5 VDC 4-20 mA 1-6 V 0-5 V, 3-wire 0-5 V, 4-wire
1-6 kHz Other:
Supply Voltage: 5 VDC 10 VDC 10-30 VDC
Electrical Connection: Cable, 2 ft Cable, 4 ft Cable, 6 ft Cable, 10 ft Bendix 6 pin
2 ft with conduit 4 ft with conduit 6 ft with conduit 10 ft with conduit
2 ft 18 AWE wires 4 ft 18 AWE wires 2 meter AWE wires
Packard Metripack 150 Other:
Sensor solutions for today and the future™
PR Series Specification SheetLevel Pressure Sensor
© Copyright Madison Company – 6/08 PS-9
Continuedon Back
PS
PRO
JECT
NO
TES
Unit Volume (annual; minimum qty. may apply): Prototype Quantity Required:
Packaging/Labeling:
Pricing Target:
Design Completion Date:
First Delivery Date:
PR Series Specification SheetLevel Pressure Sensor
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PS-10 © Copyright Madison Company – 6/08
PS
Madison Company offers an extensive line of standard optical single-point liquid level detectionswitches for use in non-coating liquids.
These compact optical switches incorporate a phototransistor that provides a digital outputindicating the presence or absence of liquid. The sensor tip houses the phototransistor in a formthat provides highly reliable and repeatable performance in compact designs.
Housings are offered in both metal and plastic with various mounting configurations. When youchoose from the extensive list of our standard part numbers, Madison can provide you with a verycost-effective solution to those level indication applications where high reliability, ease ofinstallation and maintenance-free performance are desired.
At the end of this product section, you will find the O Series Specification Sheet. This sheet can beused to define your unique optical switch requirements and application needs. By sending this toMadison Company, a custom-engineered design may be quoted.
• Accurate, repeatable switching point detection with no moving parts
• Can be mounted with limited space required
• Easy to install
• Reverse polarity, over voltage, short circuit and transient protected
Optical Liquid LevelDetection Switches
© Copyright Madison Company – 5/08 OP-1
Madison Company(203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • E-mail: [email protected]
Madison EuropePhone + 31 (0) 548 659 034 • Fax + 31 (0) 548 659 010 • E-mail: [email protected]
www.madisonco.com
OP
Standard Optical Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.OP-2 © Copyright Madison Company – 4/07
O Series Optical Liquid Level Switches
MODELDWG.NO. OPERATION MODE MOUNTING
HOUSINGMATL.
OPERATINGTEMPERATURE
SUPPLYVOLTAGE TERMINATION TYPE
Standard LLE Series Optical Switches
OPT4290-1 O-1 Digital output; high in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 250mm
OPT4290-2 O-1 Digital output; high in air From outside PSU -40˚C to 125˚C 5 to 12 VDC Lead wires, 250mm
OPT4291-1 O-2 Digital output; high in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 250mm
OPT4291-2 O-2 Digital output; high in air From outside PSU -40˚C to 125˚C 5 to 12 VDC Lead wires, 250mm
OPT4292-1 O-3 Digital output; high in air From inside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 250mm
OPT4292-2 O-3 Digital output; high in air From inside PSU -40˚C to 125˚C 5 to 12 VDC Lead wires, 250mm
OPT4293-1 O-4 Digital output; high in air From inside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 250mm
OPT4293-2 O-4 Digital output; high in air From inside PSU -40˚C to 125˚C 5 to 12 VDC Lead wires, 250mm
OPT4294-1 O-5 Digital output; high in air From outside Brass a -25˚C to 80˚C 5 to 12 VDC Lead wires, 250mm
Standard High-Reliability POS Series Optical Switches†
OPT4295-1 O-6 NPN N.O.; high in air From outside SS -25˚C to 100˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4295-2 O-6 NPN N.C.; low in air From outside SS -25˚C to 100˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4295-3 O-6 PNP N.O.; low in air From outside SS -25˚C to 100˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4295-4 O-6 PNP N.C.; high in air From outside SS -25˚C to 100˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4296-1 O-7 NPN N.O.; high in air From outside SS -25˚C to 100˚C* 12 to 28 VDC M12 Connector
OPT4296-2 O-7 NPN N.C.; low in air From outside SS -25˚C to 100˚C* 12 to 28 VDC M12 Connector
OPT4296-3 O-7 PNP N.O.; low in air From outside SS -25˚C to 100˚C* 12 to 28 VDC M12 Connector
OPT4296-4 O-7 PNP N.C.; high in air From outside SS -25˚C to 100˚C* 12 to 28 VDC M12 Connector
OPT4297-1 O-8 NPN N.O.; high in air From outside SS -25˚C to 140˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4297-2 O-8 NPN N.C.; low in air From outside SS -25˚C to 140˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4297-3 O-8 PNP N.O.; low in air From outside SS -25˚C to 140˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4297-4 O-8 PNP N.C.; high in air From outside SS -25˚C to 140˚C* 12 to 28 VDC Cable PUR 3x0.25mm sq; 2m long
OPT4298-1 O-9 NPN N.O.; high in air From outside SS -25˚C to 140˚C* 12 to 28 VDC M12 Connector
OPT4298-2 O-9 NPN N.C.; low in air From outside SS -25˚C to 140˚C* 12 to 28 VDC M12 Connector
OPT4298-3 O-9 PNP N.O.; low in air From outside SS -25˚C to 140˚C* 12 to 28 VDC M12 Connector
OPT4298-4 O-9 PNP N.C.; high in air From outside SS -25˚C to 140˚C* 12 to 28 VDC M12 Connector
Standard High-Performance LLHP Series Optical Switches
OPT4299-1 O-10 NPN N.O.; high in air From outside PSU -25˚C to 80˚C 10 to 40 VDC Lead wires, 200mm
OPT4299-2 O-10 NPN N.C.; low in air From outside PSU -25˚C to 80˚C 10 to 40 VDC Lead wires, 200mm
OPT4299-3 O-10 PNP N.O.; low in air From outside PSU -25˚C to 80˚C 10 to 40 VDC Lead wires, 200mm
OPT4299-4 O-10 PNP N.C.; high in air From outside PSU -25˚C to 80˚C 10 to 40 VDC Lead wires, 200mm
OPT4300-1 O-11 Digital output; high in air From outside SS -25˚C to 80˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-2 O-11 Digital output; high in air From outside SS -40˚C to 125˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-3 O-11 Push-pull; high in air From outside SS -25˚C to 80˚C 10 to 40 VDC Cable, 1m
OPT4300-4 O-11 Push-pull; high in air From outside SS -40˚C to 125˚C 10 to 40 VDC Cable, 1m
OPT4300-5 O-11 Digital output; high in air From outside Brass -25˚C to 80˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-6 O-11 Digital output; high in air From outside Brass -40˚C to 125˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-7 O-11 Push-pull; high in air From outside Brass -25˚C to 80˚C 10 to 40 VDC Cable, 1m
OPT4300-8 O-11 Push-pull; high in air From outside Brass -40˚C to 125˚C 10 to 40 VDC Cable, 1m
OPT4300-9 O-11 Digital output; high in air From outside SS -25˚C to 80˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-10 O-11 Digital output; high in air From outside SS -40˚C to 125˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-11 O-11 Push-pull; high in air From outside SS -25˚C to 80˚C 10 to 40 VDC Cable, 1m
OPT4300-12 O-11 Push-pull; high in air From outside SS -40˚C to 125˚C 10 to 40 VDC Cable, 1m
OPT4300-13 O-11 Digital output; high in air From outside Brass -25˚C to 80˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-14 O-11 Digital output; high in air From outside Brass -40˚C to 125˚C 5 to 12 VDC Lead wires, 150mm
OPT4300-15 O-11 Push-pull; high in air From outside Brass -25˚C to 80˚C 10 to 40 VDC Cable, 1m
OPT4300-16 O-11 Push-pull; high in air From outside Brass -40˚C to 125˚C 10 to 40 VDC Cable, 1m
Repeatability of all LLE, POS and LLHP Series Optical Switches is ±1mm. Hysteresis is 1mm (dependent on liquid). PSU = PolysulfoneAll LLE, POS and LLHP Series Optical Switches have reverse polarity protection. SS = Stainless Steel† POS Series is *not* available with NPT threads. POS Series Switches are CE approved.* Sensing tip only a Nickel-plated brass
OP
© Copyright Madison Company – 7/10 OP-3All specifications are subject to change without notice.
O Series Optical Liquid Level Switches
Standard Optical Switches (continued)
MODELDWG.NO. OPERATION MODE MOUNTING
HOUSINGMATL.
OPERATINGTEMPERATURE
SUPPLYVOLTAGE TERMINATION TYPE
Standard LLN Series Optical Switches
OPT4301-1 O-12 NPN N.O.; high in air From outside SS -40˚C to 125˚C 10 to 40 VDC M12 Connector, 3-pin
OPT4301-2 O-12 NPN N.C.; low in air From outside SS -40˚C to 125˚C 10 to 40 VDC M12 Connector, 3-pin
Standard LLC Series Optical Switches
OPT4303-3* O-14 Digital output; high in air From inside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
OPT4303-5* O-14 Digital output; low in air From inside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
OPT4305-3* O-16 Digital output; high in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
OPT4305-5* O-16 Digital output; low in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
OPT4305-9* O-16 Digital output; high in air From outside PSU -25˚C to 80˚C 24 VDC Lead wires, 200mm
OPT4305-11* O-16 Digital output; low in air From outside PSU -25˚C to 80˚C 24 VDC Lead wires, 200mm
OPT4306-3* O-17 Digital output; high in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
OPT4306-5* O-17 Digital output; low in air From outside PSU -25˚C to 80˚C 5 to 12 VDC Lead wires, 200mm
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
Repeatability of all LLN and LLC Series Optical Switches is ±1mm. Hysteresis is 1mm (dependent on liquid). PSU = PolysulfoneAll LLN Series Optical Switches have reverse polarity protection. They are *not* available with NPT threads. SS = Stainless Steel* Model has reverse polarity protection
OP
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice. OP-4 © Copyright Madison Company – 10/06
O Series Optical Liquid Level Switches
0.49”(12.4)
0.19”(4.7)
6.1” - 8.1”(155 - 205)
0.40”(10.3)
0.61”(15.5)
M12x1
R.14(3.5)
DOME
0.75”(19.0)HEX
0.75”(19.0)HEX
R.14(3.5)
CAPERUZA
M12x1
0.76”(19.4)
0.49”(12.4)
0.19”(4.7)
0.89”(22.5)
6.1” - 8.1”(155 - 205)
0.75”(19.0)HEX
0.69”(17.5)
R.14(3.5)
DOME
M12x1
6.1” - 8.1”(155 - 205)
0.41”(10.3)
0.51”(13.0)
0.57”(14.4)
LLE Series
DWG No. O-2
ø.48”(12.2)
R.14(3.5)
DOME
0.63”(16.1)
0.51”(13.0)
0.42”(10.7)
0.35”(8.9)
6.1” - 8.1”(155 - 205)
ø.39”+.004-.000
10.0+.1- 0( )
6.1” - 8.1”(155 - 205)
0.94”(24.0)HEX
1.81” MAX(46.0)
R.14(3.5)
DOME
1/2 BSPT
2.30”(58.5)
1.36”(34.5)
0.65”(16.5)
0.17”(4.2)
DWG No. O-4
DWG No. O-3
0.94”(24.0)HEX
R.22(5.5)
DOMEG 1/2
3.07” MAX(78.0)
2.64”(67.0)
1.77”(45.0)
76.8” - 80.7”(1950 - 2050)
LED
0.94”(24.0)HEX
R.22(5.5)
CAPERUZA
G 1/2
LED
M12x1CONECTORELÉCTRICO
3.07” MAX(78.0)
2.64”(67.0)
1.77”(45.0)
0.94”(24.0)HEX
R.22(5.5)
DOME
G 1/2
LED
5.43” MAX(138.0)
5.04”(128.0)
4.17”(106.0)
76.8” - 80.7”(1950 - 2050)
DWG No. O-6
DWG No. O-7
DWG No. O-8
0.94”(24.0)HEX
R.22(5.5)
DOME
G 1/2
5.43” MAX(138.0)
5.04”(128.0)
4.17”(106.0)
LED
M12x1ELECTRICALCONNECTOR
DWG No. O-9
POS Series
0.75”(19.0)HEX
R.16(4.0)
DOME
M12x1
1.17”(29.7)
0.90”(22.8)
0.59”(15.0)
1.33”(33.7)
6.9” - 8.9”(175 - 225)
DWG No. O-10
0.94”(24.0)HEX
R.16(4.0)
DOME
3/8 BSPor 1/2” NPT
2.27”(57.6)
2.11”(53.5)
1.50”(38.0)
0.12”(3.0)
5.0” - 7.0”(127 - 177.8)
DWG No. O-11
0.94”(24.0)HEX
R.14(3.5)
DOME3/8 BSP
3.54” MAX(90.0)
3.39”(86.0)
2.56”(65.0)
1.77”(45.0)
1.22”(31.0)
0.35”(9.0)
M12x1ELECTRICALCONNECTOR
DWG No. O-12
LLN Series
DWG No. O-1
DWG No. O-5
LLHP Series
ø.40”(10.2)
R.16(4.0)
DOME
M8x1
0.89”(22.7)
0.74”(18.7)
0.66”(16.7)
6.9” - 8.9”(175 - 225)
DWGNo. O-13
ø.47”(12.0)
R.16(4.0)
DOME
M10x1
0.89”(22.7)
0.74”(18.7)
0.66”(16.7)
6.9” - 8.9”(175 - 225) DWG
No. O-14
ø.47”(12.0)
R.12(3.1)
DOME10mmPRESS FIT
0.74”(18.7)
0.58”(14.7)
0.50”(12.7)
6.9” - 8.9”(175 - 225) DWG
No. O-15
0.75”(19.0)HEX
R.16(4.0)
DOME
M12x1
1.33”(33.7)
1.17”(29.7)
0.90”(22.8)
0.59”(15.0)
6.9” - 8.9”(175 - 225)
0.75”(19.0)HEX
0.92”(23.4)
0.76”(19.4)
0.49”(12.5)
0.19”(4.7)
R.16(4.0)
DOME
M12x1
6.9” - 8.9”(175 - 225)
DWGNo. O-17
LLC Series
DWGNo. O-16
OP
O SeriesOptical Liquid Level Switches
Madison’s optical liquid level switches are ideal foruse in non-coating materials
Madison Company offers an extensive lineof standard optical point level detectionswitches for use in non-coating liquids.
These compact optical switchesincorporate a phototransistor thatprovides a digital output indicating the presence or absence of liquid. Thesensor tip houses the phototransistor.The refractive index is changed whencovered by liquid, thus indicating the level.
There are several wetted materials andoperating ranges to choose from withinMadison’s optical switch series, includinghigh-temperature performance options.
As with all Madison products, engineeredconfigurations for your uniquerequirements can be quoted.
Features
• Compact size
• Solid-state technology with digital output
• Robust design
• Wire and supply current options available
• Digital (TTL output)
• Various voltage outputs available
• 4-wire option offers sensitivity adjustment
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/07 OP-5
OP
Optical Switch Series
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
OP-6 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
LLE SeriesBasic range of polysulfone optical sensors ideal for commercial and industrial applications:
• -40˚F to 257˚F (-40˚C to 125˚C)• Solid-state technology, micro-processor compatible• Reverse polarity, over voltage, short circuit and transient protected
POS SeriesHigh-performance, high-reliability sensors ideal for high or low temperatures and suitable for aggressive environments, with a wide variety of optional terminations:
• Shock resistant• Chemical resistant• Optional high switching currents• -13˚F to 284˚F (-25˚C to 140˚C)• Additional power sinking• Stainless steel housing• CE approved
LLN SeriesDesigned for harsh environments with extremes in temperature, pressure, vibration and shock. Sealed to meet IP67 in a stainless steel housing:
• Phototransistor trigger• Digital output, solid-state technology• Output: TTL 200 mA, sinking• Fast response
LLHP SeriesUtilizes the basic LLE or LLC series sensor with enhanced electronic capability to switch at higherpower or operate at higher temperatures:
• Polysulfone or metal housing• Optoschmitt trigger with digital output, compatible with TTL/CMOS
LLC SeriesA low-cost family of sensors offering high reliability. Ideal for medical, appliance and commercial applications:
• Compact size• Voltage output• Pre-wired
OP
Madison Company can engineer single-point optical switch designs for liquid level applications. To requestthis, your specific specifications must to be defined below to help us determine both the technical andeconomic requirements for your application.
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
ENVI
RO
NM
ENT
ELEC
TRIC
ALPR
OJE
CTN
OTE
S
DES
IGN
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Application Description:
Fluid: Shock: Pressure:
Temp. Range: Vibration:
Humidity Range: Immersion:
Misc. Conditions (vibration, food contact, hazardous location, turbulence, solids, approvals [i.e. UL, NSF] etc.):
Sensor Inputs: Supply Voltage: Current Consumption:
Input Protection: Trigger Signal:
Sensor Outputs: Signal Type: Voltage Swing:
Output Current: Connecting Load:
Termination Type:
Other Electrical Considerations:
Unit Volume (annual):
Packaging/Labeling:
Pricing Target:
Design Completion Date:
First Delivery Date:
Sensor solutions for today and the future™
O Series Specification SheetOptical Liquid Level Switch
© Copyright Madison Company – 9/06 OP-7
OP
OP
M SeriesUltra-Low-Level Switch Designs
Features
• Lowest reed switch liquid level indication available
• Requires 0.19” to 0.31” of liquid to become buoyant
• Efficient use of tank capacity
• Can provide early alarm
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/07 FL-1
When very low liquid levels (0.19” to 0.31”) need to be monitored, a reed switch device can be used. Madison Company’s array of ultra-low-level floats are offered in several standard levelswitch designs.
The liquid level switch configuration can featureplastic or metal stems for the ultra-low-level floatsto ride on. In the case of multi-level switches, thelow level indication can be as much as 0.57” lowerthan a typical barrel float design.
Ultra-low-level floats are available in Kynar forhigh-purity applications, PBT or Buna-N forhydrocarbon liquids and FDA-approvedpolypropylene for food applications and general-purpose liquids.
With this unique ultra-low-level monitoring ability,these switches make more efficient use of high-cost liquids, and an early indication of liquidpresence can be attained.
Madison’s Ultra-Low-Level Switches areavailable in Kynar,PBT, Buna-N,Polypropylene andPolysulfone and canmonitor liquid levelsas low as 0.19”.
FL
Standard Ultra-Low-Level Switch Floats
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
FL-2 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Kynar (Model Number: 200-M04176-K)
Maximum Temperature: 105˚CMaximum Pressure: 25 PSIGFloat Specific Gravity: 0.69Can be used on Madison Company Liquid Level Switches: M9000 and M9002-xxxx*
* Only available for bottom level of Multi-Point Switches M9002-xxxx
PBT (Model Number: 200-M04176-PBT)
Maximum Temperature: 105˚CMaximum Pressure: 25 PSIGFloat Specific Gravity: 0.55Can be used on Madison Liquid Level Switches: M4008, M4400, M4402-xxxx*, M4500, M4502-xxxx* and M7000
* Only available for bottom level of Multi-Point Switches M4402-xxxx and M4502-xxxx
Buna-N (Model Numbers: 200-M03544-NC or 200-M03544-NO)
Maximum Temperature: 105˚CMaximum Pressure: 25 PSIGFloat Specific Gravity: 0.44Can be used on Madison Liquid Level Switches: M4008, M4400, M4402-xxxx*, M4500, M4502-xxxx* and M7000
* Only available for bottom level of Multi-Point Switches M4402-xxxx and M4502-xxxx
Polypropylene (Model Number: 200-M04176-PP)
Maximum Temperature: 105˚CMaximum Pressure: 25 PSIGFloat Specific Gravity: 0.42Can be used on Madison Liquid Level Switches: M8000, M8020, M8040, M8080-xxxx, M8002-xxxx* and M8042-xxxx*
* Only available for bottom level of Multi-Point Switches M8002-xxxx and M8042-xxxx
Polysulfone (Model Number: 200-M04176-PS)
Maximum Temperature: 105˚CMaximum Pressure: 25 PSIGFloat Specific Gravity: 0.53Can be used on Madison Liquid Level Switches: M8000, M8020, M8040, M8042-xxxx* and M8080-xxxx** Only available for bottom level of Multi-Point Switch M8042-xxxx and M8080-xxxx
Standard Ultra-Low-Level Float Dimensions:Diameter: 1.875” max. Height: 1.156” for any Miniature Stem
FL
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 3/08 FL-3All specifications are subject to change without notice.
Standard FloatsAll measurements in parentheses are in millimeters.
Stainless Steel
1.50" (38.1) O.D. max.
2"(50.8)
0.59" I.D.(14.99)
2.13" (54.1) O.D. max.
2"(50.8)
0.595" I.D.(15.11)
0.555" (14.10) I.D.
1.31"(33.27)
1.54" O.D.(39.1) max. 2.05" (52.1) O.D. max.
0.555" I.D.(14.1)
Buna-N
1.25" (31.75) O.D. max.
2"(50.8)
0.59" I.D.(14.99)
Stainless Steel
1.59"(40.39)
0.90"(22.86) O.D. max.
0.35" I.D.(8.89)
1.19"(30.2)
1.13"(28.7) O.D. max.
0.35" I.D.(8.89)
Polypropylene
Polypropylene
1"(25.4) O.D. max.
1"(25.4)
0.37" I.D.(9.4)
Buna-N Kynar
1"(25.4) O.D. max.
1"(25.4)
0.34" I.D.(8.64)
1"(25.4) O.D. max.
1"(25.4)
0.37" I.D.(9.4)
3.5" (88.9) O.D. max.
0.555" I.D.(14.1)
200-M03645 200-M03196 200-P00011 200-M03656
200-P00002 200-P00004 200-M03592
200-M03890 200-P00055
200-P00001 200-P00030 200-M04378-K
1.87"(47.5) O.D. max.
1.82"(46.23)
0.62" I.D.(15.75)
0.376" I.D.(9.55)
1.18"(29.97)
O.D. max.200-P00015
Max.Temp. 150˚CMax. PSIG 120Float SG 0.61 ±.02
Max.Temp. 200˚CMax. PSIG 200Float SG 0.55
Max.Temp. 250˚CMax. PSIG 1000Float SG 0.66
Max.Temp. 200˚CMax. PSIG 300Float SG 0.28
Max.Temp. 105˚CMax. PSIG 100Float SG 0.75
Max.Temp. 105˚CMax. PSIG 150Float SG 0.45
Max.Temp. 105˚CMax. PSIG 15Float SG 0.45
Max.Temp. 200˚CMax. PSIG 300Float SG 0.70
Max.Temp. 200˚CMax. PSIG 250Float SG 0.73 ±.02
Max.Temp. 105˚CMax. PSIG 100Float SG 0.80
Max.Temp. 105˚CMax. PSIG 150Float SG 0.45
Max.Temp. 105˚CMax. PSIG 25Float SG 0.75
1"(25.4) O.D. max.
1"(25.4)
0.37" I.D.(9.4)
200-M04378-P
Max.Temp. 105˚CMax. PSIG 25Float SG 0.55
Full-Size Floats
Miniature-Size Floats
Max.Temp. 200˚CMax. PSIG 500Float SG 0.70
FL
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.FL-4 © Copyright Madison Company – 1/08
Standard FloatsAll measurements in parentheses are in millimeters.
For special applications, such as detecting water in a petroleum product, three full-size Buna-Ninterface floats with different specific gravities are available. For detection of dissimilar fluids that arenot petroleum-based, specially weighted full-size interface floats are available in polypropylene orstainless steel.
Typical application: separation of oil and water
Buna-NPolypropylene
For ultra-low-level detection, special floats which will actuate in as little as 0.19” of liquid are availableto fit various single-point and multi-point switch configurations. In the case of multi-level switches, thelow-level indication can be as much as 0.57” lower than a typical barrel float design. Ultra-low-levelfloats are available in Kynar for high-purity applications, PBT or Buna-N for hydrocarbon liquids andFDA-approved polypropylene for food applications and general-purpose liquids. With this unique ultra-low-level monitoring ability, these switches make more efficient use of high-cost liquids, and an earlyindication of liquid presence can be attained. Typical applications include sump pumps and drain pans.Please see the Ultra Low-Level Switch Designs sheet (page FL-1) in this catalog for more standardmodels and Madison level switch compatibility.
1.50" (38.1) O.D. max.
2"(50.8)
0.59" I.D.(14.99)
200-M03745 200-M03641-1200-M03641-2200-M03641-3
2.05" (52.1) O.D. max.
0.555" I.D.(14.1)
200-P00090
Stainless Steel
Ultra-Low-Level Floats
Interface Floats
Max.Temp. 105˚CMax. PSIG 100Float SG 0.95 ±.02
Max.Temp. 105˚CMax. PSIG 150Float SG
-1 0.95-2 0.87 - 0.90 (.885 ±.015)-3 0.915 ±.01
Max.Temp. 250˚CMax. PSIG 1000Float SG 0.90
1.25" (31.75) O.D. max.
2"(50.8)
0.59" I.D.(14.99)
Kynar200-M04176-K
PBT200-M04176-PBT
Buna-N200-M03544-NC200-M03544-NO
Polypropylene200-M04176-PP
Polysulfone200-M04176-PS
FL
Madison Company's expanding line of non-contact level sensors utilize both ultrasonic and radartechnologies. The U and R Series models are available in both standard and engineeredconfigurations, making them cost-effective solutions to your specific application needs. Theseproducts can provide accurate single-point or continuous level measurement for a full range ofliquids and solids. Madison’s non-contact sensors are temperature compensated, with a self-cleaning sensor face and on-board push-button calibration. Most models come withcommunication and programming capabilities to aid in self-adjusting to application conditions.
Some of these non-contact products are approved for use in hazardous locations. The U4468series of ultrasonic sensors is web enabled for remote monitoring of tanks and other vesselsthrough secure communications over the Internet.
For user-programmable settings and on-board display with alarm, the Madison-Omni® ultrasonicsensor is the compact and secure solution for continuous level measurement.
Non-ContactLevel Sensors
© Copyright Madison Company – 6/10 NC-1
Madison Company(203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • E-mail: [email protected]
Madison EuropePhone + 31 (0) 548 659 034 • Fax + 31 (0) 548 659 010 • E-mail: [email protected]
www.madisonco.com
NC
U4468
U3M
U4359
U4466
Madison-Omni®
U2
U3
R3
** Refer to Approvals pages in Reference Section
Maximum operating temperature for PVC-94V0 is 60°C. Optional materials for higher temperatures are available.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.NC-2 © Copyright Madison Company – 6/10
U and R Series Non-Contact Level Sensors
U Series Ultrasonic Sensors
MODEL
U3-70
U3-70C2
U3-70C4
U2-70
U2-80
U2-81
U2-148
(INCHES)
0.130
0.130
0.130
0.130
0.088
0.070
0.040
(MM)
3.4
3.4
3.4
3.4
2.2
1.8
0.98
RESOLUTIONMOUNTING
3.0/2.0" NPT
3.0/2.0" NPT
3.0/2.0" NPT
2.0" NPT
2.0" NPT
1.5" NPT
1.0" NPT
OPERATINGFREQUENCY
70 KHz
70 KHz
70 KHz
70 KHz
80 KHz
81 KHz
148 KHz
BEAMANGLE
12˚
12˚
12˚
12˚
12˚
12˚
12˚
VOLTS
24 DC
24 DC
24 DC
Loop PwrLoop PwrLoop PwrLoop Pwr
**APPROVALS
C,H
C,H
C,H
COMM.PORT
RS232
RS485
HOUSING MATL.STD. (OPTIONAL)
Aluminum (PVC-94V0)
Aluminum (PVC-94V0)
Aluminum (PVC-94V0)
PVC-94V0 (Aluminum)
PVC-94V0 (Aluminum)
PVC-94V0 (Aluminum)
PVC-94V0 (Aluminum)
DWGNO.
NC-4
NC-4
NC-4
NC-7
NC-7
NC-7
NC-7
(M)
0.2-9.1
0.2-9.1
0.2-9.1
0.2-9.1
0.2-6.1
0.2-4.9
0.1-2.7
RANGE
** Refer to Approvals pages in Reference Section
U Series Mini Ultrasonic Sensors
MODEL
U3M-148C485
U3M-148C485R
U3M-148S15C485
U3M-148S15C485R
(INCHES)
0.040
0.040
0.040
0.040
(MM)
0.98
0.98
0.98
0.98
RESOLUTIONMOUNTING
1" NPT
1" NPT
1" NPT
1" NPT
OPERATINGFREQUENCY
148 KHz
148 KHz
148 KHz
148 KHz
BEAMANGLE
12˚
12˚
12˚
12˚
VOLTS
24 DC
24 DC
24 DC
24 DC
** APPROVALSCOMM.PORT
RS485
RS485
RS485
RS485
HOUSING MATL.
PVC-94V0
PVC-94V0
PVC-94V0
PVC-94V0
DWGNO.
NC-9
NC-9
NC-9
NC-9
(FEET)
0.33-6
0.33-6
0.33-6
0.33-6
RANGE(M)
0.10-1.8
0.10-1.8
0.10-1.8
0.10-1.8
** Refer to Approvals pages in Reference Section
U Series Madison-Omni® Sensors
MODEL
UM4270-1
UM4270-4
UM4270-3
UM4270-6
(INCHES)
0.12
0.20
0.12
0.20
(MM)
3.0
5.0
3.0
5.0
RESOLUTIONMOUNTING
Flange
Flange
Flange
Flange
OPERATINGFREQUENCY
180 KHz
130 KHz
180 KHz
130 KHz
BEAMANGLE
8˚
8˚
8˚
8˚
VOLTS
18-30 DC
18-30 DC
18-30 DC
18-30 DC
** APPROVALS
C
C
C
C
HOUSING MATL.
SS
SS
SS
SS
DWGNO.
NC-15
NC-15
NC-15
NC-15
(FEET)
4.92
8.20
4.92
8.20
RANGE(M)
1.5
2.5
1.5
2.5
U Series Madison-Omni Sensor AccessoriesK5 PU-02SG – Ready-made cable; 5-pole, 2m length, molded-on straight plugK5 PU-05SG – Ready made cable; 5-pole, 5m length, molded-on straight plugK5 PU-10SG – Ready-made cable; 5-pole, 10m length, molded-on straight plugK5 PU-02SW – Ready-made cable; 5-pole, 2m length, molded-on 90˚ angled plugK5 PU-05SW – Ready-made cable; 5-pole, 5m length, molded-on 90˚ angled plugK5 PU-10SW – Ready-made cable; 5-pole, 10m length, molded-on 90˚ angled plugKB05 PU-W – For user-constructed cable; 5-pole, 90˚ angled plugKB05 PU-G – For user-constructed cable; 5-pole, straight plug
NC
(FEET)
0.8-30
0.8-30
0.8-30
0.8-30
0.7-20
0.6-16
0.4-9
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/10 NC-3All specifications are subject to change without notice.
U and R Series Non-Contact Level Sensors
NC
ø3.95"(ø100.3)
COVER TOOLACCESS HOLE
1/2" NPT CONDUIT ENTRY
USE PVC CONDUIT ONLY
4.75"(120.7)
øB
C A
DWGNo. NC-7
ø4.0"(ø100.3)
COVER TOOLACCESS HOLE
6.2"(157.5)
8.9"(226.1)
2.7"(68.6)
1/2" NPT CONDUIT ENTRY
USE PVC CONDUIT ONLY
3" NPT
ø3.0"(ø76.2)
DWGNo. NC-4
Ultrasonic Sensors
ø4.0"(ø101.6)
STANDARD CABLEOPTIONAL CABLE
1" NPT
4.1"(104.1) 3.125"
(79.4)1.95"(49.5)
ø1.125"(ø28.6)
DWGNo. NC-9
Mini Ultrasonic Sensors
MODEL
U2-70
U2-80
U2-81
U2-148
A
2.25" (57.2)
2.25" (57.2)
2.10" (53.3)
2.00" (50.8)
B
1.80" (45.7)
1.80" (45.7)
1.50" (38.1)
1.10" (27.9)
C
2.0" NPT
2.0" NPT
1.5" NPT
1.0" NPT
DWGNo. NC-15
Shown with optionalswan neck sensor head
Madison-Omni® Ultrasonic Sensors
MODEL
UM4270-1
UM4270-2
UM4270-3
UM4270-4
UM4270-5
UM4270-6
LENGTH
3.98" (101)
3.98" (101)
3.98" (101)
5.55" (141)
5.55" (141)
5.55" (141)
FIXED-MOUNTSENSOR HEAD
3 x ø.177” (4.5) THRU
ø2.165” (55.0)BOLT CIRCLE
ø2.756” (70.0)MOUNTING
FLANGE
SWAN NECKSENSOR HEAD
M12x1 5-POLELOCKING PLUG
LENGTH
ø1.378” (35.0)
0.591” (15.0)
M12x1 5-POLELOCKING PLUG
SET SCREW FORADJUSTING POSITIONOF SENSOR
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice. NC-4 © Copyright Madison Company – 6/10
U and R Series Non-Contact Level Sensors
R Series Radar Sensors
MODEL
R3-50C232
R3-50C485
R3-100C232
R3-100C485
(INCHES)0.22
0.22
0.44
0.44
RESOLUTION(MM)5.7
5.7
11.0
11.0
MOUNTING
2.0" NPT
2.0" NPT
2.0" NPT
2.0" NPT
OPERATINGFREQUENCY
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
BEAMANGLE
20˚
20˚
20˚
20˚
VOLTS
24 DC
24 DC
24 DC
24 DC
**APPROVALS
J
J
J
J
COMM.PORT
RS232
RS485
RS232
RS485
HOUSING MATL.STD. (OPTIONAL)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
DWGNO.
NC-10
NC-10
NC-10
NC-10
(FT)50
50
100
100
(M)15.2
15.2
30.5
30.5
RANGE
** Refer to Approvals pages in Reference Section
All the above models are available with AC or DC power and in sanitary (food-grade) designs. Please contact the factory for further information.
NC
R Series Explosion-Proof Radar Sensors
** Refer to Approvals pages in Reference Section PP = Polypropylene Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
MODEL
R3-50C232-EXP
R3-50C485-EXP
R3-50C232-EXP-T
R3-50C482-EXP-T
R3-100C232-EXP
R3-100C485-EXP
R3-100C232-EXP-T
R3-100C485-EXP-T
VOLTS
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
DWGNO.
NC-11
NC-11
NC-11
NC-11
NC-11
NC-11
NC-11
NC-11
HOUSING MATL.STD. (OPTIONAL)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
Aluminum (316 SS)
ANTENNAMATL.
PP
PP
Teflon®
Teflon®
PP
PP
Teflon®
Teflon®
COMM.PORT
RS232
RS485
RS232
RS485
RS232
RS485
RS232
RS485
(FT)
50
50
50
50
100
100
100
100
(M)
15.2
15.2
15.2
15.2
30.5
30.5
30.5
30.5
(INCHES)
0.22
0.22
0.22
0.22
0.44
0.44
0.44
0.44
(MM)
5.7
5.7
5.7
5.7
11.0
11.0
11.0
11.0
MOUNTING
2" NPT
2" NPT
2" NPT
2" NPT
2" NPT
2" NPT
2" NPT
2" NPT
OPERATINGFREQUENCY
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
6.3 GHz
BEAMANGLE
20˚
20˚
20˚
20˚
20˚
20˚
20˚
20˚
**APPROVALS
J,K
J,K
J,K
J,K
J,K
J,K
J,K
J,K
RESOLUTIONRANGE
4"(101.6)
ACCESS HOLECOVER TOOL
1/2" NPTCONDUITENTRY
ANTENNA
2" NPT
SANITARYANTENNA
2" NPT
7.3"(186.5)
10.2"(259.1) 9.4"
(238.8)
1.5"Ø(38.1)
1.5"Ø(38.1)
2.125"(54.0)
DWGNo. NC-10
ACCESS HOLECOVER TOOL
1/2" NPTCONDUITENTRY
2-11.5NPT
6.6"(168.4)
10.3"(260.4)
ø1.5(38.1)
OPTIONALSANITARY
MOUNTANTENNA
ø 3.97(100.84)
1.3"(33.6)
DWGNo. NC-11
(Explosion-Proof)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 NC-5
U SeriesMadisonic™ U4359 Short-RangeUltrasonic Level Sensor
The Madisonic™U4359 ultrasonicsensor is ideal forcontinuous levelmeasurement in small tanks.
Madison Company has designed and developed theMadisonic™ ultrasonic sensor for small-tank continuouslevel measurement. With its range of 4” to 70” (0.1m to1.78m), it is ideal for small tanks, day tanks and drums in aprocess environment.
With its accuracy of ± 0.25% of full span with temperaturecompensation at atmospheric pressure, the Madisonic is areliable sensor for the continuous monitoring of critical
liquids and some solids. A 10-degree beam angle and supply voltage of 12 to 28 VDC, coupled with ease of use and 3/4-inch NPT mounting, allow thesensor to accomodate many applications withoutfurther alterations.
The Madisonic’s attractive polycarbonate housing is very rigid and is NEMA 4X (IP65) rated. A simplegreen/red LED indicates the ultrasonic operation, and the 4-20 mA and 0-5 volt industry-standardoutputs may be used individually or at the same time. Madison Company can also offer interfacing
process controllers or indicators, which will directly connectto the Madisonic.
• Compact size
• Competitively priced
• Easy installation and operation
• LED for operation display indication
• Fixed calibration
• Nema 4X (IP65)
• FM (pending)
• Temperature compensated
• Day tanks and drums in process lines
• Small tanks for industrial liquids and certain solids
• Food and beverage
Features
Applications
NC
U4359 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-6 © Copyright Madison Company – 6/08
All specifications are subject to change without notice.
Electrical:Supply Voltage – 12 to 28 VDCOutput – 4-20 mA or 0 to 5 VDC linear
Operational:Accuracy – ± 0.25% of full span @ 22˚C (72˚F)Resolution – .040” (min.)Beam Angle – 10˚Loss of Echo – 2 mA ± 10%Calibration – Fixed Display – LEDDead Band – 4” (10.1cm)Range of Operation – 4” to 70” (0.1m to 1.78m)
Environmental:Temperature Range of Operation – -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 1 barHousing – PolycarbonateIngress Protection – NEMA 4X (IP65)Sensor – Closed-face, PVDFWetted Materials – PVDF
Mechanical:Cable Leads – 6’, 4 conductor, 24 AWG with PVC jacketMounting – 3/4” NPTApprovals – FM (pending)
Controllers, Displays, Relays and Annunciators:ESM series – Controllers, indicators and timersPD series – Programmable 4 or 8 channel controllers, multiple relays and set points,
RS232, RS422/RS485 communications and explosion-proof models availableNC
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 1/10 NC-7
U SeriesU4466 Ultrasonic Sensor
The U4466 is a self-containedultrasonic sensor.
Madison Company’s U4466 Series is an ultrasonic sensormodel designed for non-contact level, presence/absence,volume, proximity and distance measurements. This self-contained sensor is supplied with hassle-free set-upsoftware and user-selectable options that allow for a varietyof easy application interface considerations.
These microprocessor-based sensors are enhanced withinternal temperature compensation, wave action(turbulence) compensation, agitator blanking and humiditycompensation, among other user-defined settings.
The sensor adjustments and calibration can be made bythe user via a Windows™ computer and the RST modulewith its software. This computer interface may beconnected using either USB or RS-232 connections.
• Range from 4” to 79” (102 to 2007mm)
• Housing – Polycarbonate blend with 1”, 2” NPT or 2” sanitary 3A flange; wetted material is PVDF
• Programmability – Utility program supplied on CD, requires MS Windows; 5 real-time sensorstatus parameters to choose from (distance, analog output, temperature, communicationstatus and signal strength)
• Approvals – NEMA 4X, (pending), IP65
• Works with liquids and solids
• Easy to install and set up
• Virtually maintenance free
Features
NC
Applications
The U44xx series of ultrasonic sensors provide a non-contact method of detecting level,presence/absence, volume, proximity and distance measurements. With this versatility, these ultrasonic sensors are ideal for a variety of applications. Some examples are:
• Car wash vehicle position and spray arm locations• Vessel level of liquid or solid media• River, stream or irrigation canal flow and level• Waste water effluent gate for discharge rate monitoring• Process control applications for liquids
US
U4466 Series Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-8 © Copyright Madison Company – 1/10
All specifications are subject to change without notice.
Electrical:Operating Voltage – 12 to 28 VDCProgramming Voltage – for RST module: 15 to 28 VDCOutput – 4-20 mA; or 4-20 mA with (2) NPN outputs; or 0-2.5 V / 0-5 VTotal Current Draw – 75 mA @ 24 VDCMaximum Power Rating – 2.5 W
Operational:Accuracy – ±0.25% of detectable range with no temperature gradient Resolution – 0.1” (2.5mm)Beam Angle – 9˚ at full signal strength and sensitivity settingFrequency – 143 kHzTemperature Compensation – Yes, internalCalibration – Factory settings, user-programmableRange – 4” to 79” (102mm to 2007mm)Response Time – User-programmable, 20 ms minimumSampling Rate – User-programmable, 1 to 22 Hz
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 30 psi maximum (2 BAR)Installation Category – Class 1, Div. II, Groups A, B, C & D (pending)Approvals – NEMA 4X, (pending), IP65
Mechanical:Cable – Flying leads (pigtails) or micro connector (Phoenix) standardsComputer Interface – USB for RST-3001 or RS-232 for RST-2001AEnclosure – Polycarbonate/PET blend; Transducer is PVDF-faced ceramicMounting – 1” NPT; or 2” NPT; or 2” sanitary feral standards
Optional Features:Over-molded extension cables (shielded), 4-conductor or 5-conductor, with straight or right-angled Phoenix connector, in 2mm or 5mm lengths (see page 12-13 of our installationmanual for details)
NC
IRU-xxx5-M1 Brown +24VDC2 White NPN 13 Blue Ground
4 Black mA+5 Grey NPN 2
Sample Connector
(US
Madison Company’s U4467 Series is a microprocessor-basedultrasonic sensor that offers non-contact continuous levelmeasurement in a low-powered sensor suitable for hazardouslocations (when used with approved barrier). This sensor is listedby CSA for Class 1, Division I, Groups C & D and Class 1, Zone0, A Ex ia II B hazardous areas.
Featuring a ceramic transducer designed with a rugged Kynarhousing, the U4467 Series is ideal for harsh enviroments andoffers a high degree of chemical compatibility over a wide rangeof materials.
Factory settings allow you to power-up-and-use with the softwareprovided. An optional remote programmer (U4467-99) is alsoavailable, eliminating the otherwise required sensor-to-computerlink. Either way, there are a host of user-selected variables totailor the U4467 Series to your specific application. User settingscan be saved into a Word document and downloaded whenneeded, for example, to set up another sensor with identicalapplication parameters.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/10 NC-9
Madison’s U4467 Loop-PoweredUltrasonic Sensor, shown with optionalU4467-99 remote programmer
U SeriesLoop-Powered Ultrasonic Level Sensors
NC
Applications
This loop-powered 4-20 mA output ultrasonic sensor was specifically designed for measuring volume and flow of liquids. The U44xx series of ultrasonic sensors provide a non-contact method of detecting level,presence/ absence, volume, proximity and distance measurements. With this versatility, these ultrasonic sensorsare ideal for a variety of applications. Some examples are:
• Car wash vehicle position and spray arm locations• Vessel level of liquid or solid media• River, stream or irrigation canal flow and level• Waste water effluent gate for discharge rate monitoring• Process control applications for liquids
• Range from 1 to 25 feet (0.3 to 7.6m) in liquids, or 1 to 10 feet (0.3 to 3.0m) in solids
• Housing – PC/PBT with 2” NPT; wetted material is PVDF (Kynar®)
• Programmability – Fully programmable using an external programming module that acts as an interfacebetween the sensor and your personal computer. Utility program supplied on CD, requires MS Windows;5 real-time sensor status parameters to choose from (distance, analog output, temperature,communication status and signal strength)
• Approvals – Class I, Div 1, Groups C & D; Class I, Zone 0, AEx ia llB, T3; IS with approved barrier; IP65; (pending)
• Graphical representation for level, volume and flow applications
• Easy to install and set up
• Virtually maintenance free
Features
US
Electrical:Operating Voltage – 12 to 28 VDC, loop current 4-20 mAProgramming Voltage – 24 VDCOutput – 4-20 mA, loop-poweredTotal Current Draw – 4-20 mAMaximum Power Rating – 0.91 Watt
Operational:Accuracy – ±0.25% of detectable range with no temperature gradient Resolution – 0.1” (2.5mm)Beam Angle – 9˚ off-axisFrequency – 68 kHzTemperature Compensation – Yes, internalCalibration – Factory settings, user-programmable with U4467-99 or USB-to-computer,
software providedRange – 1 to 25 feet (0.3 to 7.6m) in liquids; 1 to 10 feet (0.3 to 3.0m) in solidsResponse Time – Dependent on output ranges, from 0.6 to 3 secondsSampling Rate – 2 seconds
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 30 psi maximum (2 BAR)Installation Category – Class 1, Div. 1, Groups C & D; Class 1, Zone 0, A Ex ia, T3Approvals – IP65, (pending), IS
Mechanical:Cable – 2-conductor shielded, with 6-foot length standardComputer Interface – USB through U4467-99 programmerEnclosure – Polycarbonate/PBT blend; Transducer is ceramic with PVDF housingMounting – 2” NPT
Optional Features:Remote Programmer (U4467-99)
Safety Barrier:Recommended Stahl part number 9001/51-280-091-141
U4467 Series Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-10 © Copyright Madison Company – 2/10
All specifications are subject to change without notice.
NC
o y
US
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 3/10 NC-11
U SeriesWeb-Enabled Ultrasonic Sensors
Madison Company’s U4468 Series of Web-enabled ultrasonicsensors are ideal for monitoring both local and remote tanklocations. The non-contact measurements that can be obtainedfrom the U4468 Series are level, presence/absence, volume anddistance. Each individual sensor model is designed for a specificrange (span).
The Internet connection from any computer will provide access toa secure site – after you enter your sensor’s IP address set-up,measurements will begin to be logged in real time. You canprogram the website to send you an E-mail, text message orboth, as well as set two relays for pump control and/or alarm.
Sensor parameters and settings can be changed via the sensor’sinternal Web page and the unique IP address. This affordableremote tank monitoring set-up provides, essentially, maintenance-free service.U4468 Series Ultrasonic Sensors are
web enabled for monitoring both localand remote tank locations.
NC
• Detect ranges from 1 foot to 15 feet (model dependent)
• Housing – Polycarbonate blend with 2” or 3” NPT; wetted material is PVDF
• Programmability – Ethernet connections to World Wide Web to secure host server (ideal for remotemonitoring); AutoSence software for hassle-free set up
• Approvals – Class I, Div 2, Groups A B C & D; (pending)
• Works on liquids and solids
• Calculates level or volume of vessel’s contents
• Storage of readings to a secure, private database
• Remote monitoring and control and/or alarm features
Features
Applications
This loop-powered 4-20 mA output ultrasonic sensor was specifically designed for measuring volume and flow of liquids. The U44xx series of ultrasonic sensors provide a non-contact method of detecting level,presence/absence, volume, proximity and distance measurements. With this versatility, these ultrasonic sensorsare ideal for a variety of applications. Some examples are:
• Car wash vehicle position and spray arm locations• Vessel level of liquid or solid media• River, stream or irrigation canal flow and level• Waste water effluent gate for discharge rate monitoring• Process control applications for liquids
US
U4468 Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-12 © Copyright Madison Company – 3/11
All specifications are subject to change without notice.
Electrical:Operating Voltage – 48 VDC POE; Sensor is powered over Ethernet cable – requires POE
injector or switchOutput – Ethernet TCP/IP to internal Web page;
(2) isolated solid state relays (130 mA maximum)Total Current Draw – 40 mA @ 48 VDCMaximum Power Rating – 2.0 WElectrical Connection – RJ-45 port; terminal blocks for relay connections
Operational:Accuracy – ±0.25% of detectable range with no temperature gradient Resolution – 0.1” (2.5mm)Beam Angle – 9˚ off-axis at full signal strength and sensitivity settingsFrequency – U4468-1 and -3 are 69 kHz; U4468-2 is 43 kHz Temperature Compensation – Yes, internalCalibration – User-programmableRange – 1 to 25 feet (305mm to 7620mm) for U4468-1
1.5 to 40 feet (457mm to 12192mm) for U4468-24” to 180” (102mm to 4572mm) for U4468-3
Response Time – User-programmableSampling Rate – User-programmable, 1 to 12 Hz
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 30 psi maximum (2 BAR)Installation Category – Class 1, Div. II, Groups A, B, C & DApprovals – IP65, (pending), IS
Mechanical:Computer Interface – Windows XP or higherEnclosure – Polycarbonate/PBT blend; Transducer is ceramic with PVDF housingMounting – 2” NPT for U4468-1 and U4468-3; 3” NPT for U4468-2
Optional Features:7 ft. orange crossover (P/N 136282) 7 ft. blue cable (P/N 136284-0007)7 ft. red cable (P/N 136283-0007) 25 ft. blue cable (P/N 136284-0025)25 ft. red cable (P/N 136283-0025) POE power supply, 48V, 0.42 A & cable (P/N 136281-0001)
Safety Barrier:Recommended Stahl part number 9001/51-280-091-141
NC
Installation Category –IP65, (pending), IS
US
• Pulse ultrasonic technology
• Non-contact measurement
• Programmable
• Field/Bench calibration
• Push-button calibration
• Elimination ofunwanted echoes
• Food and beverage
• Water and wastewater
• Microprocessor-based reliability
• Temperature compensation
• Self-cleaning sensor face
• Non-volatile memory (batteries not required)
• Automatic adjustment of power andsensitivity to any environment
• Window Out of unwanted echoes
• Electrical and acoustical noise filters
• Chemicals and oils
• Various liquids, slurries and solids
Madison Company offers a complete line of Standardmodels of advanced ultrasonic level measurementsensors for liquids and solids. These products continueto meet demanding applications in many markets, atcompetitive prices.
In addition, Madison Company has the engineeringcapabilities to design these sensors for your specificnon-contact level measurement needs, providingunique considerations for materials to be measured,vessel configuration and system interfacing.
The microprocessor-based circuits provide atemperature-compensated signal for improvedaccuracy. All models have the ability to filter falseechoes produced by peripheral obstructions.
Continuous level measurement can be provided in a range of 0.16’ to 30’ (0.049m to 9.1m) with severalpower and programmability options. Point level can alsobe obtained using a PLC (Industrial ProgrammableController). Measurement of solids requires thecommuncations option; when selecting a standardmodel for these cases, cut the range of the unit in half.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/10 NC-13
Space-savingmodels areavailable withremote sensorsthat can beseparated fromhousings by upto 6 feet.
U SeriesUltrasonic Level Sensors
Features
Applications
NC
Electrical:Power Options – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
R load = (Vs–6)/24 mAOutput – 4-20 mA or 20-4 mA, 6.1 uA resolution; 750 ohms (isolated
on 4-wire models only)Optional RS232 or RS485 communications port
Fuse – 0.125 Amps/250 V type 2AG
Operational:Accuracy – ±0.25% of max. target range (in air) Beam Angle – 6-12 degrees at -3 dB (model dependent)Loss of Echo Hold – 1 minute (programmable 1-4 min.), 22 mA or 2 mA current outputTemperature Compensation – Onboard the sensorCalibration – Push-button or optional programmableDiagnostics (Echo Profile) – Via optional programmable portDead Zone Range – Model dependent or engineered to minimum
Environmental:Operating Temperature Range: -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 1 BAR (15 PSIG max.)Approval – Entela, CE (in aluminum enclosure)
Mechanical:Conduit Entry – 1/2” NPT hole (PVC only)Enclosure – PVC-94V0, aluminumIngress Protection – NEMA 4X (IP65)Mounting Options – Swivel socket (cold-rolled steel); PVC flange with 3”-8 or 6”-8 NPT thread
Optional Features:Sanitary designsBSP thread typesVarious housing materials (may affect approval)High-temperature designsRemote displayBall coupler with 3” NPT thread for mounting and easy beam alignment
Approvals:Consult factory
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-14 © Copyright Madison Company – 6/10
All specifications are subject to change without notice.
NC
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 NC-15
U SeriesMadison-Omni® Sensors forShort-Range Measurement
The Madison-Omni®
integrated displaydesign is available for ultrasonic (non-contact) sensors
In addition to the Madison-Omni® configurations featured inMadison’s reed-switch-based continuous level devices, theMadison-Omni® design is available as an ultrasonic sensorfor short-range (8” - 48” or 12” - 90”) measurement.
There are four models and two standard ranges availablewith the integrated Madison-Omni® display. This universaldisplay is the same one utilized in reed-switch-based levelmeasurement. It offers user-programmable settings and, inaddition to the displayed values, features an LED alarm light.
This non-contact level measurement sensor can be used invarious liquids and solids. Level measurement can bedisplayed in inches or centimeters. As with all ultrasonicdevices, you should avoid turbulance or sloping surfaces onthe level to be measured.
• Range: 8” - 90”
• Ultrasonic level sensing with integrated user-programmable display
• Narrow 8˚ beam width
• Adjustable ranges and alarm set points (NPN or PNP)
• Scalable 4-20 mA output
• Several mounting options
Features NC
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-16 © Copyright Madison Company – 1/09
All specifications are subject to change without notice.
Electrical:Supply Voltage – 18 to 30 VDCPower Consumption – < 3 WattsOutput – 4(0)-20 mA, 2(0)-10 V across; 500 Ohm resistor to 0 VSwitching Values (S1 and S2) – PNP or NPN selectable; 300 mA load sum max.;
programmable as min. or max. value; short circuit proof; reverse polarity proofHysteresis – Adjustable; position depends on min. or max. settingDisplay – Graphical LCD display; temperature range -20˚C to 70˚C (-4˚F to 158˚F);
32x16 pixels; back-lit LED signaling lamp Connection – M 12x1; 5-pole locking plug*
Operational:Accuracy – ±0.2% full scale Linearity Error – < 0.3% full scaleTemperature Error – 0.03% ˚COperating Temperature – 0˚C to 70˚C (32˚F to 158˚F)Operating Pressure – Ambient
Environmental:Approval – IP67, CE
Mechanical:Wetted Materials – PET 30% GV, epoxy resin, POMHousing Materials – Stainless steel, tempered glass, POM ringMounting – Flange mount with center hole 35.5mm and three fastening through holes for
screws or bolts
Options:Swan Neck – Optional swan neck between the electronics head and the primary sensor
provides complete freedom in the sensor alignment and reading direction. Additionallyprovides thermal decoupling between units. See catalog drawing #NC-15 for illustration.
Operating RangeDead Zone
Emergency-Off Contact
4.3’ (1.3m)7.5’ (2.3m)
0.66’ (0.2m)0.98’ (0.3m)
Type: 4.9’ (1.5m)8.2’ (2.5m)
8˚
Madison-Omni® Operation: Wiring Diagram: 18 to 30 VDC
4(0)-20 mA
OmniSensor
white
brown
gray
black
bluez
z
Z = load
1
2
3
4
5
z
or NPNExample: PNP
0 V
S1
S2
NC
* Madison-Omni® Sensor Accessories (sold separately)029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug
029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 NC-17
U SeriesU3M “Mini Probe” Ultrasonic Level SensorsMadison Company’s “Mini Probe” is an addition to the fullrange of ultrasonic level sensors already offered. Its design iscompact, extending just over 2” in height above the tank ordrum surface, and it has an operating range of 4” to 6’(0.10m to 1.8m).
As with all of our standard Ultrasonic models, the U3M has aPVC housing that allows for an operating temperature rangeof -40˚C to 60˚C (-40˚F to 140˚F). This range can beincreased to 80˚C (176˚F) with an optional CPVC housing orincreased to 125˚C (257˚F) with an optional Kynar housing.
The U3M’s microprocessor-based circuits provide atemperature-compensated signal for improved accuracy andthe ability to filter false echoes produced by peripheralobstructions. On-board push buttons allow for calibrationwithout the need for software and computers. OptionalRS485 communications are available for computer interfacingand for networking up to 128 sensors. Relay models foralarm and/or on/off control by sensor can be provided.
For applications requiring a sanitary interface to the sensor, an optional 316L stainless steel transducer face withtri-clover clamp is also available.
• Pulse ultrasonic technology
• Non-contact measurement
• Programmable
• Push-button calibration
• Elimination ofunwanted echoes
• Microprocessor-based reliability
• Food and beverage
• Water and wastewater
• Temperature compensation
• Field or bench calibration
• Self-cleaning sensor face
• Non-volatile memory (batteries not required)
• Automatic adjustment of power andsensitivity to any environment
• Low profile
• Chemicals and oils
• Various liquids, slurries and solids
Features
Applications
U3M Ultrasonic “Mini Probe”
NC
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-18 © Copyright Madison Company – 6/08
All specifications are subject to change without notice.
Electrical:Power Options – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
R load = (Vs–6)/24 mAOutput – 4-20 mA, 6.1 uA resolution
Relay: DPST, 5 Amps @ 230 VACOptional RS485 communications port (comes with free software)Note: If a converter is required, Madison recommends B & B Electronics Model 485SD9TB
Operational:Accuracy – ±0.25% of max. target range (in air) Beam Angle – 12 degrees at -3 dBLoss of Echo Hold – 1 minute (programmable 1-4 min.), 22 mA or 2 mA current outputTemperature Compensation – Onboard the sensorCalibration – Push-button or optional programmableDiagnostics (Echo Profile) – Via optional programmable portHigh-Level Alarm – 5 Amp relay has hysteresis and delay of 5% of the tank height;
changes at full tank calibration heightRange – 0.33’ to 6’ (0.10m to 1.8m)Resolution – 0.04” (0.98mm)Operating Frequency – 148 kHz
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Pressure – 1 BAR to 2 BARInstallation Category – Class 11Approval – CE
Mechanical:Cable – 24 AWG, 3 pair, 60” long (1.5m); Relay option requires 18 AWG, 3 conductorEnclosure – PVC-94V0Ingress Protection – NEMA 4X (IP65)Mounting Options – Swivel socket (cold-rolled steel); PVC flange with 3”-8 or 6”-8 NPT thread
Optional Features:U3M-148 Standard modelU3M-148C485 with communications portU3M-148-R with relay U3M-148C485-R with communications port and relayFor higher operating temperatures, request factory quote for a CPVC or Kynar housing.
NC
Madison Company offers a series of low-costradar sensors for continuous levelmeasurement. This product series offers alogical extension to the ultrasonic sensorseries, where application conditions are in need of non-contact liquid level measurement,and where ultrasonic level measurement is not acceptable.
As with all Madison products, this radartechnology can be designed for your specificlevel measurement needs, providing uniqueconsiderations for materials to be measured,vessel configuration and system interface.
These radar level sensors are ideal forreflective liquids that have a foaming surface or vapor conditions beyond ultrasonic wave capabilities.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/08 NC-19
R SeriesRadar Level Sensors
Features• Non-contact measurement
• Continuous level measurement
• Pulse radar measurement range 10” to 100’ (0.254m to 30m)
• Networkable, multi-sensor with available software
• Programmable and push-button calibration
• Various liquids and solids
Applications
NC
Electrical:Power Options – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
R load = (Vs–6)/24 mAOutput – 4-20 mA, 6.1 uA resolution; 750 ohms
Optional RS232 or RS485 communications port
Operational:Accuracy – ±0.25% of max. target range (in air)
Frequency – 5.8 GHz or 6.3 GHzLoss of Echo Hold – 30 seconds, 22 mA outputTransmitter Power – 50 uW averageCalibration – Programmable via communications portDiagnostics (Echo Profile) – Via programmable portAntenna – Dielectric rod
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Installation Category – Class IIApprovals – FCC Part 15 – low-power communication device
– CE – 5.8 GHz models
Mechanical:Conduit Entry – 1/2” NPT standardHousing – Aluminum or stainless steel 316L (optional)Ingress Protection – NEMA 4 (IP65)Decoupler – PolypropyleneMounting Options – Swivel socket (cold-rolled steel); PVC flange with 3”-8 NPT thread
Options:PTFE antenna or sanitary PTFE antenna1.5” or 2” NPT PTFE decoupler for high-temperature applicationsSanitary designsAntenna extension: 6” or 8”
Approvals:Consult factory
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-20 © Copyright Madison Company – 6/10
All specifications are subject to change without notice.
NC
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/10 NC-21
R SeriesSanitary “Smart” RadarLevel Measurement Sensors
Features• Programmable and push-button calibration
• Output: 4-20 mA/20-4 mA (isolated on 4-wire models only)
• PLC compatible (Modbus RTU)
• 3-wire operation
• Food and beverage
• Water
• Pharmaceutical
Applications
Standard sanitaryunit features
aluminum housing, polypropylene antenna and 2” tri-clamp
MODEL
R3-50S3-wire, DC
R3-100S3-wire, DC
RANGEIn Liquids
* to 50’(* to 15m)
* to 100’(* to 30m)
RESOLUTION
0.22”(5.7mm)
0.44”(11mm)
TRI-CLAMPFitting
2.0”
2.0”
* Minimum distance starts at the lower tip of the antenna.
NC
Electrical:Power – DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
R Load = (Vs–6)/24 mAOutput – 4-20 mA output, 6.1 uA resolution; 750 ohms
RS232 or RS485 communications port
Operational:Operation – Pulse radarAccuracy – ± 0.1% of maximum range in lab using 4-20 mA current output
± 0.25% of maximum range (typically in field)Frequency – 5.8 GHz or 6.3 GHzLoss of Echo Hold – 30 seconds, 22 mA output timeTransmitter Power – 50 uW averageCalibration – Programmable via communications port or push buttonDiagnostics (Echo Profile) – Via communications portAntenna Dielectric Rod – Polypropylene (standard), PTFE (optional)Decoupler – Polypropylene (standard), PTFE (optional)
Environmental:Operating Temperature Range – -40˚C to 60˚C (-40˚F to 140˚F)Installation Category – Class IIApprovals – FCC Part 15 – low-power communication device
Mechanical:Conduit Entry – 1/2” NPT standardEnclosure – Aluminum (standard) or stainless steel 316L (optional)Ingress Protection – NEMA 4 (IP65)Mounting Options – Swivel socket (galvanized steel); PVC flange with 3”-8 NPT thread
Process:Temperature – PTFE Rod: -40˚C to 204˚C (-40˚F to 400˚F) with tri-clampMaterial Dielectric – Class IIPressure – 1-10 BAR, 15-150 PSI
Approvals:CE approval on 5.8 GHz modelsConsult factory for others
Specifications
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
All specifications are subject to change without notice.
NC-22 © Copyright Madison Company – 6/10
NC
Unit Volume (monthly): Packaging/Labeling:
Price Target:
Stocking/Shipping Requirements:
Design Completion Date: First Delivery Date:
ENVIRONMEN
TELEC
TRICAL
PHYS
ICAL
NOTES
DES
IGN
Application description:
Material to be measured:
Vessel construction (wall material, shape, size):
Max. distance from top of vessel to lowest measurement point: Turbulence?
Level range – Min: Max: Normal: Liquid? Solid?
Ambient temperature range (inside the vessel) – Min: Max: Normal:
Material density: Units: Material dielectric constant:
Pressure – Min: Max: Normal: Units: Vented? Vacuum?
Washdown required? IP rating required: 3A?
Other considerations (vibration, food contact, hazardous location, turbulence, foams, solids, approvals, filling method, vapors/dust, etc.):
Installation: Indoors or Outdoors Intrinsically safe or Explosion proof
Output: 4-20 mA 20-4 mA 0-5 V 5-0 V PNP NPN N.O.N.C.
Communications: RS232 RS485 None Wireless Type required:
Power: 3-wire: 24 VDC 2-wire: Loop powered
Resolution: Accuracy: Repeatability:
Terminations:
Cable length:
Mounting considerations:
Antenna Material: Polypropylene (standard) PTFE
Sanitary design High temperature (above 140˚F)
PROJECT
See reverse side for Considerations for Sensor Applications
Madison Company can engineer the ultrasonic or radar sensor to meet your application needs. Please provide thefollowing information so that our engineering staff can determine the appropriate sensor design for your requirements.
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
U or R Series Specification Work SheetUltrasonic or Radar Sensor
Sensor solutions for today and the future™
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
© Copyright Madison Company – 6/10 NC-23
NC
Considerations for Sensor Applicationsin a Typical Vessel, Container or Tank
Sensor Location?*
Mounting Style?Fill Location?
Wall Material/Surface Typeand Shape?
Distance?
TemperatureRange InsideVessel?
Material to Measure?Foam (Depth)?
Valve
Vapor? Y N
Dust? Y NType:
Condensation? Y N
Cavitation? Y N(Air Bubbles)
Turbulence? Y N
Foam? Y N
Obstructions?
* Note: Sensor must be installed on the top of the vessel. Please indicate hole location.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
NC-24 © Copyright Madison Company – 6/10
Tank Shape?
Shape of Tank Top?
Top of Tank:Open
Closed
Shape of Tank Bottom?
Power Required: 24 VDC (3-Wire) Loop Power (2-Wire)
Communications: RS232 RS485 Mod Bus Wireless required
Liquid Solid
Slurry
NC
Madison Company has been incorporating temperature sensors into its level switch products for
over 50 years. With this temperature sensor experience, a basic standard product line has been
established to complement our capability to design and manufacture application-specific sensors.
Madison’s temperature offerings include:
• Thermocouples
• RTDs (Resistance Temperature Detectors)
• Madison-Omni® RTDs with integrated user-programmable controls
• Bimetal Thermal Switches
• Indicators and Controllers
• Accessories for Temperature Sensors
Temperature Sensors,Controllers & Accessories
© Copyright Madison Company – 3/11 TM-1
Madison Company(203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • E-mail: [email protected]
Madison EuropePhone + 31 (0) 548 659 034 • Fax + 31 (0) 548 659 010 • E-mail: [email protected]
www.madisonco.com
TM
Thermocouples
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice.TM-2 © Copyright Madison Company – 7/09
T Series Standard Temperature Sensors
MODEL CALIBRATION TYPEWIRE SIZE
(DIA.)
OVERALL LENGTH
(INCHES) (M)
T4271-J5 J 0.005” 12 0.3
T4271-J10 J 0.010” 12 0.3
T4271-J15 J 0.016” 12 0.3
T4271-J20 J 0.020” 12 0.3
T4271-J30 J 0.032” 12 0.3
T4271-K5 K 0.005” 12 0.3
T4271-K10 K 0.010” 12 0.3
T4271-K15 K 0.016” 12 0.3
T4271-K20 K 0.020” 12 0.3
T4271-K30 K 0.032” 12 0.3
T4271-T5 T 0.005” 12 0.3
T4271-T10 T 0.010” 12 0.3
T4271-T15 T 0.016” 12 0.3
T4271-T20 T 0.020” 12 0.3
T4271-T30 T 0.032” 12 0.3
MODELCALIBRATION
TYPESHEATHMATL.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
WIRESIZE
OVERALL LENGTH
TERMINATIONTIP
STYLE(INCH) (MM) (INCH) (M)
T4269-J12NC25 J 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-J12MP25 J 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-J12CP25 J 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-K12NC25 K 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-K12MP25 K 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-K12CP25 K 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-T12NC25 T 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-T12MP25 T 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-T12CP25 T 316 SS 0.250 6.35 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-J12NC12 J 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-J12MP12 J 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-J12CP12 J 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-K12NC12 K 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-K12MP12 K 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-K12CP12 K 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-T12NC12 T 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-T12MP12 T 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-T12CP12 T 316 SS 0.125 3.18 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-J12NC19 J 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-J12MP19 J 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-J12CP19 J 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-K12NC19 K 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-K12MP19 K 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-K12CP19 K 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
T4269-T12NC19 T 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Strip lead Closed
T4269-T12MP19 T 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Mini plug Closed
T4269-T12CP19 T 316 SS 0.188 4.76 MgO Grounded 24 AWG 12 0.3 Full-size plug Closed
Bare-wire thermocouples. Sold in packages of 10 pieces.
General-purpose thermocouples with fiberglass-insulated extensionleads and various termination styles.
TM
© Copyright Madison Company – 4/07 TM-3All specifications are subject to change without notice.
T Series Standard Temperature Sensors
Thermocouples
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
MODELCALIB.TYPE
SHEATHMATL.
MAX.TEMP.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
WIRESIZE
OVERALL LENGTHPROCESS
CONNECTIONTIP
STYLE(INCH) (MM) (INCH) (M)
T3966-1001 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 2 0.05 1/4” tube Closed
T3966-1002 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 6 0.15 1/4” tube Closed
T3966-1003 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 12 0.30 1/4” tube Closed
T3966-2001 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 2 0.05 1/4” tube Closed
T3966-2002 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 6 0.15 1/4” tube Closed
T3966-2003 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 12 0.30 1/4” tube Closed
T3967-1001 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 2 0.05 1/4” tube Closed
T3967-1002 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 6 0.15 1/4” tube Closed
T3967-1003 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 12 0.30 1/4” tube Closed
T3967-2001 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 2 0.05 1/4” tube Closed
T3967-2002 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 6 0.15 1/4” tube Closed
T3967-2003 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 12 0.30 1/4” tube Closed
T3964-1001 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 2 0.05 1/2” NPT Closed
T3964-1002 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 6 0.15 1/2” NPT Closed
T3964-1003 J 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 12 0.30 1/2” NPT Closed
T3964-2001 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 2 0.05 1/2” NPT Closed
T3964-2002 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 6 0.15 1/2” NPT Closed
T3964-2003 J 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 12 0.30 1/2” NPT Closed
T3965-1001 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 2 0.05 1/2” NPT Closed
T3965-1002 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 6 0.15 1/2” NPT Closed
T3965-1003 K 316 SS 200˚C 0.188 4.76 Epoxy Ungrounded 24 AWG 12 0.30 1/2” NPT Closed
T3965-2001 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 2 0.05 1/2” NPT Closed
T3965-2002 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 6 0.15 1/2” NPT Closed
T3965-2003 K 316 SS 200˚C 0.250 6.35 Epoxy Ungrounded 24 AWG 12 0.30 1/2” NPT Closed
MODELCALIBRATION
TYPESHEATHMATL.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
CABLELENGTH
OVERALL LENGTH
TERMINATIONTIP
STYLE(INCH) (MM) (INCH) (M)
T4268-J12C J 316 SS 0.250 6.35 MgO Grounded 5' 12 0.30 Mini connector Closed
T4268-J24C J 316 SS 0.250 6.35 MgO Grounded 5' 24 0.60 Mini connector Closed
T4268-J36C J 316 SS 0.250 6.35 MgO Grounded 5' 36 0.90 Mini connector Closed
T4268-K12C K 316 SS 0.250 6.35 MgO Grounded 5' 12 0.30 Mini connector Closed
T4268-K24C K 316 SS 0.250 6.35 MgO Grounded 5' 24 0.60 Mini connector Closed
T4268-K36C K 316 SS 0.250 6.35 MgO Grounded 5' 36 0.90 Mini connector Closed
T4268-T12C T 316 SS 0.250 6.35 MgO Grounded 5' 12 0.30 Mini connector Closed
T4268-T24C T 316 SS 0.250 6.35 MgO Grounded 5' 24 0.60 Mini connector Closed
T4268-T36C T 316 SS 0.250 6.35 MgO Grounded 5' 36 0.90 Mini connector Closed
T4268-J12NC J 316 SS 0.250 6.35 MgO Grounded 10' 12 0.30 Stripped ends Closed
T4268-J24NC J 316 SS 0.250 6.35 MgO Grounded 10' 24 0.60 Stripped ends Closed
T4268-J36NC J 316 SS 0.250 6.35 MgO Grounded 10' 36 0.90 Stripped ends Closed
T4268-K12NC K 316 SS 0.250 6.35 MgO Grounded 10' 12 0.30 Stripped ends Closed
T4268-K24NC K 316 SS 0.250 6.35 MgO Grounded 10' 24 0.60 Stripped ends Closed
T4268-K36NC K 316 SS 0.250 6.35 MgO Grounded 10' 36 0.90 Stripped ends Closed
T4268-T12NC T 316 SS 0.250 6.35 MgO Grounded 10' 12 0.30 Stripped ends Closed
T4268-T24NC T 316 SS 0.250 6.35 MgO Grounded 10' 24 0.60 Stripped ends Closed
T4268-T36NC T 316 SS 0.250 6.35 MgO Grounded 10' 36 0.90 Stripped ends Closed
Thermocouples with reduced tip for improved response time. The probe comes with a nylon handle, cable strain reliefand extension cable. Overall length listed below refers to probe only.
General-purpose epoxy-insulated thermocouples.
TM
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice. TM-4 © Copyright Madison Company – 1/09
T Series Standard Temperature Sensors
MODELCALIB.TYPE
SHEATHMATL.
MAX.TEMP.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
WIRESIZE
OVERALL LENGTHTIP
STYLE(INCH) (MM) (INCH) (M)
T4267-J20TFEEC J N/A 200˚C N/A N/A PTFE jacket Enclosed 20 AWG 120 3.00 Epoxy coated
T4267-J24TFEEC J N/A 200˚C N/A N/A PTFE jacket Enclosed 24 AWG 120 3.00 Epoxy coated
T4267-K20TFEEC K N/A 200˚C N/A N/A PTFE jacket Enclosed 20 AWG 120 3.00 Epoxy coated
T4267-K24TFEEC K N/A 200˚C N/A N/A PTFE jacket Enclosed 24 AWG 120 3.00 Epoxy coated
T4267-T20TFEEC T N/A 200˚C N/A N/A PTFE jacket Enclosed 20 AWG 120 3.00 Epoxy coated
T4267-T24TFEEC T N/A 200˚C N/A N/A PTFE jacket Enclosed 24 AWG 120 3.00 Epoxy coated
T4267-J20TFEEJ J N/A 250˚C N/A N/A PTFE jacket Exposed 20 AWG 120 3.00 Bare
T4267-J24TFEEJ J N/A 250˚C N/A N/A PTFE jacket Exposed 24 AWG 120 3.00 Bare
T4267-K20TFEEJ K N/A 250˚C N/A N/A PTFE jacket Exposed 20 AWG 120 3.00 Bare
T4267-K24TFEEJ K N/A 250˚C N/A N/A PTFE jacket Exposed 24 AWG 120 3.00 Bare
T4267-T20TFEEJ T N/A 250˚C N/A N/A PTFE jacket Exposed 20 AWG 120 3.00 Bare
T4267-T24TFEEJ T N/A 250˚C N/A N/A PTFE jacket Exposed 24 AWG 120 3.00 Bare
T4267-J20FGEJ J N/A 500˚C N/A N/A Fiberglass jacket Exposed 20 AWG 120 3.00 Bare
T4267-J24FGEJ J N/A 500˚C N/A N/A Fiberglass jacket Exposed 24 AWG 120 3.00 Bare
T4267-K20FGEJ K N/A 500˚C N/A N/A Fiberglass jacket Exposed 20 AWG 120 3.00 Bare
T4267-K24FGEJ K N/A 500˚C N/A N/A Fiberglass jacket Exposed 24 AWG 120 3.00 Bare
T4267-T20FGEJ T N/A 400˚C N/A N/A Fiberglass jacket Exposed 20 AWG 120 3.00 Bare
T4267-T24FGEJ T N/A 400˚C N/A N/A Fiberglass jacket Exposed 24 AWG 120 3.00 Bare
T4267-J20HTEJ J N/A 700˚C N/A N/A Fiberglass jacket* Exposed 20 AWG 120 3.00 Bare
T4267-J24HTEJ J N/A 700˚C N/A N/A Fiberglass jacket* Exposed 24 AWG 120 3.00 Bare
T4267-K20HTEJ K N/A 700˚C N/A N/A Fiberglass jacket* Exposed 20 AWG 120 3.00 Bare
T4267-K24HTEJ K N/A 700˚C N/A N/A Fiberglass jacket* Exposed 24 AWG 120 3.00 Bare
T4267-J20PVCEC J N/A 90˚C N/A N/A PVC Jacket Exposed 20 AWG 120 3.00 Bare
T4267-K20PVCEC K N/A 90˚C N/A N/A PVC Jacket Exposed 20 AWG 120 3.00 Bare
T4267-T20PVCEC T N/A 90˚C N/A N/A PVC Jacket Exposed 20 AWG 120 3.00 Bare
T4267-J20PVCEJ J N/A 90˚C N/A N/A PVC Jacket Enclosed 20 AWG 120 3.00 Epoxy coated
T4267-K20PVCEJ K N/A 90˚C N/A N/A PVC Jacket Enclosed 20 AWG 120 3.00 Epoxy coated
T4267-T20PVCEJ T N/A 90˚C N/A N/A PVC Jacket Enclosed 20 AWG 120 3.00 Epoxy coated
Thermocouples
MODELCALIBRATION
TYPESHEATHMATL.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
OVERALL LENGTH
TERMINATIONTIP
STYLE(INCH) (MM) (INCH) (M)
T4266-J12 J 316 SS 0.250 6.35 MgO Grounded 12 0.30 1” bare leads Closed
T4266-J21 J 316 SS 0.250 6.35 MgO Grounded 24 0.60 1” bare leads Closed
T4266-K12 K 316 SS 0.250 6.35 MgO Grounded 12 0.30 1” bare leads Closed
T4266-K21 K 316 SS 0.250 6.35 MgO Grounded 24 0.60 1” bare leads Closed
T4266-T12 T 316 SS 0.250 6.35 MgO Grounded 12 0.30 1” bare leads Closed
T4266-T21 T 316 SS 0.250 6.35 MgO Grounded 24 0.60 1” bare leads Closed
Sheathed thermocouples with MgO insulation, grounded junction. Sold in packages of 6 pieces.
MODELCALIBRATION
TYPESHEATHMATL.
SHEATH ODINSULATIONMATERIAL
JUNCTIONTYPE
OVERALL LENGTH
TERMINATIONTIP
STYLE(INCH) (MM) (INCH) (M)
T4274-JA* J 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
T4274-KA* K 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
T4274-TA* T 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
T4274-J1** J 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
T4274-K1** K 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
T4274-T1** T 316 SS 0.250 6.35 MgO Grounded 18 0.40 1” bare leads Closed
Industrial thermocouples with 1/2” NPT process connection and aluminum or cast iron J-box.
* Aluminum J-box ** Cast iron J-box
Thermocouples with mini plug termination.
* High-temperature fiberglass jacket.
TM
© Copyright Madison Company – 4/07 TM-5All specifications are subject to change without notice.
T Series Standard Temperature Sensors
RTDs (Resistance Temperature Detectors)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
MODELOHM
VALUEPROBE
MATERIALMAX.TEMP.
PROBE LENGTH PROBE DIAMETER
WIRES TERMINATION(INCH) (M) (INCH) (MM)
T4272-4A 100 316 SS 200˚C 4 0.10 0.250 6.4 3 Aluminum J-box
T4272-6A 100 316 SS 200˚C 6 0.15 0.250 6.4 3 Aluminum J-box
T4272-9A 100 316 SS 200˚C 9 0.22 0.250 6.4 3 Aluminum J-box
T4272-12A 100 316 SS 200˚C 12 0.30 0.250 6.4 3 Aluminum J-box
T4272-4N 100 316 SS 200˚C 4 0.10 0.250 6.4 3 Plastic J-box
T4272-6N 100 316 SS 200˚C 6 0.15 0.250 6.4 3 Plastic J-box
T4272-9N 100 316 SS 200˚C 9 0.22 0.250 6.4 3 Plastic J-box
T4272-12N 100 316 SS 200˚C 12 0.30 0.250 6.4 3 Plastic J-box
Industrial 100 ohm RTD probes, rigid mount. Process connection is 1/2” NPT with 1/2” conduit connection.
MODELOHM
VALUEPROBE
MATERIALMAX.TEMP.
PROBE LENGTH PROBE DIAMETER
WIRES TERMINATION(INCH) (M) (INCH) (MM)
T4273-2-9 100 316 SS 200˚C 9 0.22 0.250 6.4 2 #8 spade terminals
T4273-2-12 100 316 SS 200˚C 12 0.30 0.250 6.4 2 #8 spade terminals
T4273-2-18 100 316 SS 200˚C 18 0.45 0.250 6.4 2 #8 spade terminals
T4273-3-9 100 316 SS 200˚C 9 0.22 0.250 6.4 3 #8 spade terminals
T4273-3-12 100 316 SS 200˚C 12 0.30 0.250 6.4 3 #8 spade terminals
T4273-3-18 100 316 SS 200˚C 18 0.45 0.250 6.4 3 #8 spade terminals
RTD probes with 48” Teflon®-jacketed cables terminated with spade terminals.
MODELOHM
VALUEPROBE
MATERIALMAX.TEMP.
PROBE LENGTH PROBE OD
WIRES INSULATION TERMINATION(INCH) (M) (INCH) (MM)
T3969-1001 100 316 SS 200˚C 2 0.05 0.188 4.8 2, 22 AWG Teflon® Leads
T3969-1002 100 316 SS 200˚C 6 0.15 0.188 4.8 2, 22 AWG Teflon® Leads
T3969-1003 100 316 SS 200˚C 12 0.30 0.188 4.8 2, 22 AWG Teflon® Leads
T3969-2001 100 316 SS 200˚C 2 0.05 0.250 6.4 2, 22 AWG Teflon® Leads
T3969-2002 100 316 SS 200˚C 6 0.15 0.250 6.4 2, 22 AWG Teflon® Leads
T3969-2003 100 316 SS 200˚C 12 0.30 0.250 6.4 2, 22 AWG Teflon® Leads
T3968-1001 100 316 SS 200˚C 2 0.05 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3968-1002 100 316 SS 200˚C 6 0.15 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3968-1003 100 316 SS 200˚C 12 0.30 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3968-2001 100 316 SS 200˚C 2 0.05 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
T3968-2002 100 316 SS 200˚C 6 0.15 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
T3968-2003 100 316 SS 200˚C 12 0.30 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
T4198 100 316 SS 200˚C 316 SS plug N/A N/A 3, 24 AWG Teflon® 2 x 1/16” NPT
T3971-1001 1000 316 SS 200˚C 2 0.05 0.188 4.8 2, 22 AWG Teflon® Leads
T3971-1002 1000 316 SS 200˚C 6 0.15 0.188 4.8 2, 22 AWG Teflon® Leads
T3971-1003 1000 316 SS 200˚C 12 0.30 0.188 4.8 2, 22 AWG Teflon® Leads
T3971-2001 1000 316 SS 200˚C 2 0.05 0.250 6.4 2, 22 AWG Teflon® Leads
T3971-2002 1000 316 SS 200˚C 6 0.15 0.250 6.4 2, 22 AWG Teflon® Leads
T3971-2003 1000 316 SS 200˚C 12 0.30 0.250 6.4 2, 22 AWG Teflon® Leads
T3970-1001 1000 316 SS 200˚C 2 0.05 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3970-1002 1000 316 SS 200˚C 6 0.15 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3970-1003 1000 316 SS 200˚C 12 0.30 0.188 4.8 2, 22 AWG Teflon® 1/2” NPT
T3970-2001 1000 316 SS 200˚C 2 0.05 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
T3970-2002 1000 316 SS 200˚C 6 0.15 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
T3970-2003 1000 316 SS 200˚C 12 0.30 0.250 6.4 2, 22 AWG Teflon® 1/2” NPT
RTD probe style is closed tip.
TM
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice. TM-6 © Copyright Madison Company – 4/07
T Series Standard Temperature Sensors
Madison-Omni® RTDs
MODEL NECK STYLE
PROBE LENGTH TEMPERATURE RANGE
THREAD(INCH) (MM) (˚C) (˚F)
T4275-1 Vertical 1.96 50 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-2 Swan 1.96 50 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-3 Swan 1.96 50 0˚C to 250˚C 32˚F to 482˚F NPT 1/2 A
T4275-4 Vertical 3.93 100 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-5 Swan 3.93 100 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-6 Swan 3.93 100 0˚C to 250˚C 32˚F to 482˚F NPT 1/2 A
T4275-7 Vertical 5.90 150 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-8 Swan 5.90 150 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-9 Swan 5.90 150 0˚C to 250˚C 32˚F to 482˚F NPT 1/2 A
T4275-10 Vertical 7.87 200 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-11 Swan 7.87 200 0˚C to 100˚C 32˚F to 212˚F NPT 1/2 A
T4275-12 Swan 7.87 200 0˚C to 250˚C 32˚F to 482˚F NPT 1/2 A
T4275-13 Vertical 1.96 50 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-14 Swan 1.96 50 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-15 Swan 1.96 50 0˚C to 250˚C 32˚F to 482˚F G 1/2 A
T4275-16 Vertical 3.93 100 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-17 Swan 3.93 100 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-18 Swan 3.93 100 0˚C to 250˚C 32˚F to 482˚F G 1/2 A
T4275-19 Vertical 5.90 150 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-20 Swan 5.90 150 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-21 Swan 5.90 150 0˚C to 250˚C 32˚F to 482˚F G 1/2 A
T4275-22 Vertical 7.87 200 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-23 Swan 7.87 200 0˚C to 100˚C 32˚F to 212˚F G 1/2 A
T4275-24 Swan 7.87 200 0˚C to 250˚C 32˚F to 482˚F G 1/2 A
Madison-Omni® RTD Sensor Accessories029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
User-programmable indicator that provides range indication and offers two alarm settings. The platinum RTD sensor with a 316 stainless steel sheath has an analog 4-20 mA outputsignal and a supply voltage of 10-30 VDC. The electrical connection has an M 12x1 thread; ifa mating connector is required, one of the accessory cables (listed below) should be ordered.The process connection is available with either a G 1/2 or a 1/2” NPT thread and meets IP67.
TM
© Copyright Madison Company – 4/07 TM-7All specifications are subject to change without notice.
Temperature Indicators and Controllers
Temperature Indicators
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
MODEL BASE UNIT PART NO.
SIZE (W x H) DISPLAY HEIGHT
DISPLAY DIGITS(INCH) (MM) (INCH) (MM)
ESM-4400 ESM-4400-12011/0000 1.89 x 1.89 48 x 48 0.39 10.0 4
ESM-4900 ESM-4900-12011/0000 3.78 x 1.89 96 x 48 0.80 20.3 4
ESM-7700 ESM-7700-12011/0000 2.83 x 2.83 72 x 72 0.55 14.0 4
ESM-9900 ESM-9900-12011/0000 3.78 x 3.78 96 x 96 0.55 14.0 4
Base indicator with NO contact, programmable to NC for reverse action. Display has fourprocess and four set points. Supply voltage is 100-240 VAC, 50/60 Hz. Features a universalinput for thermocouple, RTD (2- or 3-wire), analog 0-50 V, 0-5 V, 0-10 V or 4-20 mA. Alsoincludes a communications port for RS232 MODBUS.
Additional module chips are available (specify indication model): Output: Input:– Relay Output – Thermocouple– SSR Output (15-18 VDC / 50 mA) – RTD– Transistor Output (24 VDC / 100 mA)– Volt/Current Output (0/4-20 mA, 0-10 V)
Temperature Controllers
MODEL BASE UNIT PART NO.
SIZE (W x H) DISPLAY HEIGHT
DISPLAY DIGITS(INCH) (MM) (INCH) (MM)
ESM-4450 ESM-4450-12011/0000 1.89 x 1.89 48 x 48 0.39 10.0 4
ESM-7750 ESM-7750-12011/0000 2.83 x 2.83 72 x 72 0.55 14.0 4
ESM-9450 ESM-9450-12011/0000 1.89 x 3.78 48 x 96 0.39 10.0 4
ESM-9950 ESM-9950-12011/0000 3.78 x 3.78 96 x 96 0.55 14.0 4
Base controller with NO contact, programmable to NC for reverse action. Display has fourprocess and four set points (8mm height). Features a universal input for thermocouple, RTD(2- or 3-wire), analog 0-50 V, 0-5 V, 0-10 V or 4-20 mA, and can accept a second input modulechip. Communications port is RS232 MODBUS; an optional RS485 port can be requested.
Additional module chips are available (specify indication model): Output: Input:– Relay Output – Thermocouple– SSR Output (15-18 VDC / 50 mA) – RTD– Transistor Output (24 VDC / 100 mA)– Volt/Current Output (0/4-20 mA, 0-10 V)
Other wire gauges, insulation types and lengths are available. Contact factory for details.
TM
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
All specifications are subject to change without notice. TM-8 © Copyright Madison Company – 4/07
Temperature Sensor Accessories and Kits
Accessories
MODEL TYPE DESCRIPTION
Thermocouple Extension Wires011-P00003-J25 J 24 AWG, TFE-jacketed, 25’ long
011-P00004-K25 K 24 AWG, TFE-jacketed, 25’ long
011-P00008-T25 T 24 AWG, TFE-jacketed, 25’ long
Miniature Connectors018-P00173 J Plug style
018-P00174 K Plug style
018-P00175 T Plug style
018-P00189 J Jack style
018-P00190 K Jack style
018-P00191 T Jack style
Full-Size Connectors018-P00178 J Plug style
018-P00179 K Plug style
018-P00180 T Plug style
018-P00184 J Jack style
018-P00185 K Jack style
018-P00186 T Jack style
Temperature Kits
MODELTEMPERATURESENSOR TYPE INDICATOR CONTROLLER
TK-CB001 RTD 1000 ohm No Yes
TK-CB002 Thermocouple Type J No Yes
TK-CB003 Thermocouple Type K No Yes
TK-CD001 RTD 1000 ohm No Yes*
TK-CD002 Thermocouple Type J No Yes*
TK-CD003 Thermocouple Type K No Yes*
TK-DB001 RTD 1000 ohm Yes No
TK-DB002 Thermocouple Type J Yes No
TK-DB003 Thermocouple Type K Yes No
TK-DD001 RTD 1000 ohm Yes* No
TK-DD002 Thermocouple Type J Yes* No
TK-DD003 Thermocouple Type K Yes* No
* With bench-top enclosure and fused input power setup.
Madison Temperature Kits include a temperature sensor(RTD or choice of J or K Thermocouples) and either abasic temperature indicator or a full-featured controller. The kits contain all of the hardware that is necessary tomeasure temperature (Basic kits – TK-xBxxx) or measure temperature and control a process (Deluxe kits –TK-xDxxx). Each kit includes complete wiring instructionsand a stainless steel compression fitting to mount thetemperature sensor. Also included in each kit are MadisonCompany Application Notes to guide you through the set-up of the indicator or controller. Choose from Basic kits with a panel-mountedinstrument or Deluxe kits that have the instrument factory assembled into a bench-top enclosure. The Deluxe kits alsoinclude a fused power inlet and mating 120 VAC power cord.
TK-CB003
TK-DB003
TM
T SeriesType K, J & T Thermocouples
Madison Company’s T Series thermocouples aredesigned specifically for long life and reliability using well-established engineering techniques. They are intendedfor use in measuring environmental temperatures inindustrial applications from engines and ovens todishwashers and heaters. Madison Company’s engineersconsider all aspects of the application including vibration,mechanical and thermal shock, time response, hightemperature and other environmental extremes.
The T Series Type K, J and T have a typical constructionof grounded, ungrounded or exposed tips using stainlesssteel sheath material, standard lead lengths of 24” withcustomer-specified terminations. Tip configurations canbe general purpose, penetration, air surface or tapered.
Madison Company’s thermocouple assemblies areconstructed from a variety of materials that are selectedfor the performance capability required by the applicationfor which they are designed. In addition to materialselections, junction style will also be considered withregard to time response requirements.
All Madison thermocouple products are manufacturedunder our strict total quality management system in conformance with ISO 9001:2000. T Seriesthermocouples are available in custom configurations tomeet the unique requirements of individual applications.
Typical configurations of T-typethermocouples. Madison’sengineers will design a customprobe to your specifications.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 TM-9
Features
• Custom configuration to customer specifications
• Wide selection of thermocouple styles, sheath materials and insulation materials
• All thermocouple material is certified, traceable to N.I.S.T.
• Sheath coatings can be provided to enhance the thermocouple
TM
Junctions
Protecting Sheath
Three main styles of thermocouple junctions are available on T Seriesthermocouples:
• Closed tip – specified when a pressure seal or protection from the atmosphereis desired. Can be made with an isolated junction or grounded junction.
• Exposed junction – specified when IR radiation or contamination by-productsare not a factor, or where fast response to temperature change is desired.
• Shielded junction – used when it is necessary to reduce the effect of radiationon accuracy but still maintain a fast response time.
Insulation Materials
Typical Design Specifications
Terminations and Leads
Although maximum sensitivity is achieved with an exposed thermocouple, the majority of applicationsrequire that the thermocouple wires be protected from mechanical damage by a tube. Sheath materials canbe specified from a variety of metals, including various stainless steels, usually 300 series or alloys.
T Series terminations can be supplied with a wide variety of terminal, stud, junction box and connectorconfigurations. All terminations are manufactured from materials that eliminate undesired junctions. Leadwires can be designed with overbraid and other forms of protection.
Magnesium oxide (MgO) is the most commonly used insulation; however, other materials such asaluminum oxide (Al2O2) and boron nitride (BN) are available.
Refer to the Madison Company Temperature Sensor Specification Sheet.For interfacing controllers, refer to Madison's E Series products.Interconnect cable assemblies can also be supplied.
Isolated
ExposedShielded
Closed Tip
Grounded
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-10 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
TM
T SeriesRTDs (Resistance Temperature Detectors)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 TM-11
Features
• Interchangeable without sensor-to-sensor recalibration
• Very small thermal mass for fast response time
• Air or liquid temperature sensing
• Proven reliability
• Long-term stability
Madison Company’s T Series ResistanceTemperature Detectors (RTDs) are selected for theirhigh accuracy. Used in a multitude of process, foodand HVAC applications, these general-purpose RTDsare offered with a choice of elements and insulatingmaterials, providing the user with a range of valuesand accuracies. Choices in lead wire, sheathmaterials and terminations are also available.
Madison’s thin-film platinum RTDs are available in100 Ohm or 1,000 Ohm versions and are suitable forapplications that require small envelope size andlinear output. The T Series RTDs respond rapidly totemperature changes with an accuracy of ±0.7˚C at20˚C. Dependent upon the application requirements,the outside sheath materials and insulation materialswill determine the sensor assembly’s response time.Termination and fit up options are directly related tothe application specifications of the customer.
The typical configurations are three wire output -40˚C to 125˚C (-40˚F to 257˚F).
Madison Company can also provide the interfacingtransmitters, interconnecting cable and controllers fora matched subsystem.
Typical platinum RTDs offered by Madison Company provide a change in resistance thatcorresponds to a temperaturechange.
TM
Typical Applications• HVAC – room, duct and refrigerant temperatures
• Process Control – temperature regulation
• Appliances – cooking and cleaning temperatures
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-12 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Specifications
Thin-film platinum RTD
-40˚C to 125˚C (-40˚F to 257˚F)
±0.7˚C
100 or 1000 ohms
Customer defined, dependent on application
Customer defined, dependent on application
Sensor Type
Temperature Range
Temperature Accuracy
Resistance at 0˚C
Sheath Material
Termination and Leads
TM
T SeriesTemperature Sensor Kits
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 3/11 TM-13
Features
• Choice of temperature sensor -1000 ohm RTD or Type J or K Thermocouple
• Choice of digital temperature indicator or full-featured process controller
• Stainless steel compression fitting for easy mounting of the sensor
• Complete wiring instruction and application notes
• Built-in front panel interface for easy indicator set-up
Madison Company has been incorporating temperature sensors into
its level switch products for over 50 years. As an extension of this
experience, these temperature kits provide the user with the
components that are required to either measure temperature or
measure temperature and control a process.
Temperature kits are available with your choice of sensor:
• 1000 ohm RTD
• Type J Thermocouple
• Type K Thermocouple
The Basic Temperature Kits provide the user with a basic set of
components that can be incorporated into a variety of applications
that require temperature measurement and/or process control. Both
the indicator and controller are designed for panel mounting using
supplied hardware.
Deluxe Temperature Kits are turn-key and feature an indicator or
controller assembled in a bench-top enclosure with all of the
electrical (AC power) wiring completed. All the user needs to do is
mount the sensor, connect it to the indicator or controller and plug in
the power cord.
Madison Temperature Kits include a temperature sensor (RTD or
choice of J or K Thermocouples) and either a basic temperature
indicator or a full-featured controller. The kits contain all of the
hardware that is necessary to measure temperature (Display kits
TK-Dxxxx) or measure temperature and control a process (Controller
kits TK-Cxxxx). Each kit includes complete wiring instructions and a
stainless steel compression fitting to mount the temperature sensor.
Also included in each kit are Madison Company Application Notes to
guide you through the setup of the indicator or controller.
TK-CB003
TK-CD003
Basic Indicator Kit
Deluxe Controller Kit
TM
Temperature Sensor Kits
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-14 © Copyright Madison Company – 3/09
All specifications are subject to change without notice.
MODEL TEMPERATURE SENSOR TYPE INDICATOR CONTROLLER
TK-CB001 RTD 1000 ohm Yes Yes
TK-CB002 Thermocouple Type J Yes Yes
TK-CB003 Thermocouple Type K Yes Yes
TK-DB001 RTD 1000 ohm Yes No
TK-DB002 Thermocouple Type J Yes No
TK-DB003 Thermocouple Type K Yes No
MODEL TEMPERATURE SENSOR TYPE INDICATOR CONTROLLER
TK-CD001 RTD 1000 ohm Yes Yes
TK-CD002 Thermocouple Type J Yes Yes
TK-CD003 Thermocouple Type K Yes Yes
TK-DD001 RTD 1000 ohm Yes No
TK-DD002 Thermocouple Type J Yes No
TK-DD003 Thermocouple Type K Yes No
Basic Temperature Indicator & Process Controller Kits Panel-Mounted Instruments
Deluxe Temperature Indicator & Process Controller Kits Bench-Top Enclosure Instruments
Process Indicator Features:• Large 4-digit display – digits are 0.80” (20.3mm) high• Plug-in output module design• On-board sensor power supply• Universal process input (TC, RTD, VDC, mA)
Process & Temperature Controller Features:• 4 digits process and 4 digits set display• Universal process input (TC, RTD, VDC, mA)• Dual- or multi-point calibration for V and mA inputs• Programmable ON/OFF and PID control forms
Both of these units feature standard relay output. Additional input and output modules are availableto meet your requirements.
TM
T SeriesMadison-Omni®RTD Temperature Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 1/07 TM-15
Features
• Provides the accuracy of RTD sensors with the easy-to-use convenience ofthe user-programmable Madison-Omni® display interface
• Compact design
• Adjustable limits and alarm points with LED alarm light
• 4-20 mA output
In addition to being offered with our continuous levelsensing products (reed switch or ultrasonic), theMadison-Omni® integrated display/control unit can beprovided with a platinum RTD (resistance temperaturedetector) temperature sensor tip. Featuring the sameuser-programmable interface utilized throughout theMadison-Omni® family, the RTD can be set for twoalarm points and offers a uniform readout for severalsensor monitoring options.
There are 12 standard configurations available for thisMadison-Omni® temperature sensor, all usingplatinum RTD technology. The temperature range ismodel dependent.Madison-Omni ® RTD
temperature sensor with integrated display/control
TM
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-16 © Copyright Madison Company – 1/09
All specifications are subject to change without notice.
SpecificationsElectrical:
Supply Voltage – 10-30 VDC ±10% Maximum Load – 700 Watts @ 24 V (100 Watts @ 10 V, 1K @ 30 V, linear to the
operation voltage)Output – 4-20 mAPlug Connection – M 12x1*Cable Length Options (sold separately) –
5-pole shielded cable with 90˚ angled connector in 2m, 5m or 10m lengths5-pole shielded cable with straight connector in 2m, 5m or 10m lengths
Mechanical:Sheath Material – 316 stainless steel Thread – 1/2” NPT
Operational:
Standard Models
T4275-1T4275-2T4275-3T4275-4T4275-5T4275-6T4275-7T4275-8T4275-9T4275-10T4275-11T4275-12T4275-13T4275-14T4275-15T4275-16T4275-17T4275-18T4275-19T4275-20T4275-21T4275-22T4275-23T4275-24
Neck Style
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
VerticalSwanSwan
Probe Length
1.96” (50mm)1.96” (50mm)1.96” (50mm)3.93” (100mm)3.93” (100mm)3.93” (100mm)5.90” (150mm)5.90” (150mm)5.90” (150mm)7.87” (200mm)7.87” (200mm)7.87” (200mm)1.96” (50mm)1.96” (50mm)1.96” (50mm)3.93” (100mm)3.93” (100mm)3.93” (100mm)5.90” (150mm)5.90” (150mm)5.90” (150mm)7.87” (200mm)7.87” (200mm)7.87” (200mm)
Thread
NPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 ANPT 1/2 A
G 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 AG 12 A
Temperature Range
0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 100˚C (32˚F to 212˚F)0˚C to 250˚C (32˚F to 482˚F)
* Madison-Omni® Sensor Accessories (sold separately)029-P00001 – Shielded cable; 2m length with straight plug029-P00002 – Shielded cable; 5m length with straight plug029-P00003 – Shielded cable; 10m length with straight plug
029-P00004 – Shielded cable; 2m length with 90˚ angled plug029-P00005 – Shielded cable; 5m length with 90˚ angled plug029-P00006 – Shielded cable; 10m length with 90˚ angled plug
TM
T SeriesThermistors (Thermally Sensitive Resistors)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 TM-17
Features
• Interchangeable without sensor-to-sensor recalibration
• Very small thermal mass for fast response time
• Air or liquid temperature sensing
• Proven reliability
• Long-term stability
Madison Company’s T Series Thermistors(THERMally sensitive resISTORS) are selected fortheir high accuracy. Used in a wide variety of process,food and HVAC applications, these general-purposeThermistors are offered with a choice of elements andinsulating materials, providing the user with a range ofvalues and accuracies. Choices in lead wires, sheathmaterials and terminations are also available.
Madison’s Thermistors are available in NegativeTemperature Coefficient (NTC) versions. NTCThermistors exhibit decreasing electrical resistancewith increases in environmental temperature andincreasing electrical resistance with decreasingtemperature.
The T Series Thermistors respond rapidly totemperature changes, with an accuracy of ±2˚C.Depending on the application requirements, theoutside sheath materials and insulation materials willdetermine the sensor assembly’s response time.Termination and fit up options are directly related tothe application specifications of the customer.
Typical Thermistors offered byMadison Company.
TM
Typical Applications• HVAC – room, duct and refrigerant temperatures
• Process Control – temperature regulation
• Appliances – cooking and cleaning temperatures
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-18 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Specifications
Thermistor
-80˚C to 150˚C (-112˚F to 302˚F)
±0.2˚C
Customer defined, dependent on application
Customer defined, dependent on application
Sensor Type
Temperature Range
Temperature Accuracy
Sheath Material
Termination and Leads
TM
T SeriesBimetal Thermal Switches
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/07 TM-19
Madison Company offers a full range of thermal switches that can be designed as a stand-alonetemperature sensor or combined into liquid level switches. The thermal switches are preciselycalibrated devices that cover a broad temperature range. Configurations using snap-action bimetallicdisk, bimetal slow make/slow break, rod and tube and solid state construction are also available tooffer a broad array of temperature control solutions.
The bimetal contact movement is achieved using the different expansion rates of two metals fusedtogether. This is a creep action device, providing very-close-tolerance temperature sensing andhaving small differential. The set point range is 30˚C to 130˚C. All thermal switches are factory-calibrated to customer-defined set point range.
Features
• Bimetal construction
• Creep action (slow make/slow break switching) or snap action
• Low differential between opening/closing temperatures
• Various contact types and ratings are available, depending on application
• Available in open on rising temperature or close on rising temperature configuration
• Close on rising available from 30˚C to 130˚C (86˚F to 266˚F)
• Open on rising available from 30˚C to 125˚C (86˚F to 257˚F)
• Accuracy of ±5˚C (±9˚F)
• Rated life: 100,000 cycles, depending on application
• Repeatability of ±1˚C (±1.8˚F)
• Small size permits flexible and innovative product enhancementsTM
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
TM-20 © Copyright Madison Company – 5/08
All specifications are subject to change without notice.
Typical Applications• HVAC – room, duct and refrigerant temperatures
• Process Control – temperature regulation
• Appliances – cooking and cleaning temperatures
• Motors – overload protection
Specifications
Bimetal Thermal Switch
30˚C to 130˚C (86˚F to 266˚F)
±5˚C (±9˚F) – Special tolerances can be quoted
Customer defined, dependent on application
Customer defined, dependent on application
Quick make/quick break switching
In some cases, the differential between opening/closing temperatures can be specified from 2˚C to 40˚C (36˚F to 104˚F); most models have“zero” differential
Various ratings available, depending on application
Sensor Type
Temperature Range
Temperature Accuracy
Sheath Material
Termination and Leads
Snap Action
Temperature Differential
Contact Ratings
Madison Company offers two types of Bimetal Switches:
Creep ActionCreep action is when the switch element is designed to open slowly at the rated temperature. Many switches have atemperature differential between the opening and closing temperature. This type of action may be useful in anapplication where the switch is being used as a protection device for when the temperature of the process has rapidtransient changes. The creep action tends to “average” the changes and prevent nuisance operation of the switch.This is also important because most of the temperature switches listed for protection applications are listed for alimited number of cycles. This type of switch is intended for use as a protection device only.
Snap ActionThese switches are called snap action because they open very rapidly (“snap”) at the rated temperature. This type isusually best for thermostat applications. They typically have no (or very small) temperature differential betweenopening and closing. They will respond to relatively short-lived changes in temperature, which can make them cyclevery frequently in applications where the temperature changes often.
TM
Madison Company can engineer temperature sensors to meet your application needs. Please provide theinformation requested below so that our Engineering Department can determine the appropriate sensordesign for your application.
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
© Copyright Madison Company – 2/05 TM-21
SENSO
R TYP
E
Temperature Switch: Open on rising Close on rising
@ degrees C or F Tolerance: (±%)
Snap action Creep action
Current capacity: Amps @ Volts AC or DC
RTD Sensor: 100 Ohm 1000 Ohm
Temperature range – High limit: Low limit: degrees F or C
Critical range of measurement:
Thermistors: Resistance Ohms @ 25 degrees C Tolerance (%)
Temperature range – High limit: Low limit: degrees F or C
Critical range of measurement:
Thermocouples: Type J Type K Type T
Temperature range – High limit: Low limit: degrees F or C
Critical range of measurement:
Accuracy – Standard limits: Special limits:
Junction type: Ungrounded Grounded Exposed
OUTP
UT
Output: Direct 4-20 mA 0-5 V Other
Interface requirements: Controller Digital thermometer Relay Other
PACK
AGIN
G
Media (type and concentration): Pressure:
Probe length: Diameter:
Mounting connection: Flange – Size: Weight:
Pipe thread – Size: Inside mount Outside mount
Bulkhead fitting – Size:
Adjustable fitting – Size:
Lead termination: Bare leads – Length:
Insulated ext. cable – Length: Type:
Connector – Type:
Junction box – Size: Type:
Other:
Environmental (special requirements, e.g. immersion):
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
T Series Specification SheetTemperature Sensor
Continuedon Back
TM
Sensor solutions for today and the future™
APPL
ICAT
ION DES
CRIPTION
DES
IGN
PROJE
CT
Unit Volume (monthly):
Packaging/Labeling:
Pricing Target:
Stocking/Shipping Requirements:
Design Completion Date:
First Delivery Date:
TM-22 © Copyright Madison Company – 2/05
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
T Series Specification SheetTemperature Sensor
St
TM
P SeriesProximity Sensors
Madison Company’s P Series proximity sensors use reedswitch-based technology, which offers reliability of up to 5 million cycles. Offered in both plastic and metalhousings, these proximity sensors are interchangeablewith existing sensors of similar characteristics or can bedesigned specifically for individual application needs.
These noncontact sensors are available with single poledouble throw switches (Form C), or Form A and B. Theyoffer a variety of ways to sense the relative position ofspecific machine elements requiring continuousmonitoring. Several different fabrication materials can beused. Materials are selected based on the applicationenvironment. The standard operating temperature rangeis from -40˚C to 125˚C (-40˚F to 257˚F).
Sensors can be ordered in sets containing the sensor, the actuator and hardware, or the components can beordered separately. These cost-effective sensors areoffered in standard designs and engineered designs withvarious actuation points.
DIRECTIONS OFUSE FOR PROPERACTUATION
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 PR-1
Typical standard product designsoffered from stock.
Features
• Fully potted switch and leads
• High cycle rate capabilities
• High-speed operation
• Compact for limited-spaceapplications
• No moving parts, for longer life
• Corrosion-resistant
• Wide selection of materials
• Engineered designs available
PR
Proximity Sensors
Specifications for Representative Standard Products
Contact Form
Maximum Voltage(based on switch selection)
Maximum Switching Amps
Watts (max.)
Contact Resistance
Breakdown Voltage
Operating Temperature
“Must Operate” Distance
“Must Release” Distance
Standard Actuator Size
Operating Time
Release Time
Leads (standard)(3 leads with color options)
P300 SeriesStainless Steel
A (SPDT)
300 V
.5 A
50 W
.1 Ohm maximum
600 VDC
-40˚C to 125˚C
.200”
.600”
.670” OD x .200” H
.6 msec
.05 msec
24”, 22 AWG Teflon®
P450 SeriesPVC
1C
120 VDC; 120 VAC
3 A
100 W
.5 Ohm maximum
250 VDC
0˚C to 60˚C
.200”
.700”
1.125” OD x .470” H
3 msec
3 msec
24”, 22 AWG Teflon®
P400 SeriesStainless Steel
1C
120 VDC; 120 VAC
3 A
100 W
.5 Ohm maximum
250 VDC
-40˚C to 125˚C
.200”
.700”
1.125” OD x .470” H
3 msec
3 msec
24”, 22 AWG Teflon®
WIRE LEADSSEE CHART FOR
LENGTH AND TYPE
4.030" (102.4)3.330" (84.6)
2.415"(61.3)0.188" (4.8)
4 PLACES
.210"(5.3)
1/2" NPT 1.105"(28.1)
.214"(5.4)
1" (25.4)square
1" (25.4)square
WIRE LEADSSEE CHART FOR
LENGTH AND TYPE
2.750"(69.9)
1.000"(25.4)
.750"(19.1)
1/2" NPT 5/8-18THREAD
WIRE LEADSSEE CHART FOR
LENGTH AND TYPE 1.575"(40.0)
HEX NUT5/16-18
THREAD
P450 Series P400 Series P300 Series
Wiring Chart
Common Black
NC Yellow
NO Green
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
PR-2 © Copyright Madison Company – 5/08
PR
Madison Company can engineer proximity sensors to meet your application needs. Please provide theinformation requested below so that our Engineering Department can determine the appropriate switchdesign for your application.
ENVI
RO
NM
ENT
ELEC
TRIC
ALPH
YSIC
ALPR
OJE
CTN
OTE
S
DES
IGN
Customer: Contact Name:
Address:
Phone No.: Fax No.: E-mail:
Application Description:
Fluid:
Temp. Range: Max. Pressure:
Misc. Conditions (vibration, food contact, hazardous location, turbulence, solids, approvals [i.e. UL, NSF], etc.):
Contact Form (1A, 1B or 1C): Voltage:
Type of device being controlled:
Operating Time: Release Time: Switch Amps:
Misc.:
Operational Distance: Release Distance:
Lead Length: Lead Color:
Connector/Terminations:
Mounting:
Unit Volume (monthly):
Packaging/Labeling:
Pricing Target:
Stocking/Shipping Requirements:
Design Completion Date:
First Delivery Date:
Sensor solutions for today and the future™
Madison Company27 Business Park Dr., Branford, CT 06405800-466-5383 • 203-488-4477 • Fax: 203-481-5036www.madisonco.com • E-mail: [email protected]
© Copyright Madison Company – 2/05 PR-3
P Series Specification SheetProximity Sensors
St
PR
PR
E Series
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 7/06 AC-1
Features
• Input can be scaled for a linear readout; 4-20 mA input is reversible
• Base models are offered in industry-recognized sizes
• Module chips allow for many input configurations for the same base model
• Minimal down time
• Software is downloadable to text file for easy uploading, without having toprogram each individual unit
• Communication port standard; network port optional
Madison Company offers a full line of process controllers, indicatorsand timer/counters that mate to any of our liquid level switches,ultrasonic sensors, thermocouples or RTD temperature sensors.
This common family of interfacing devices offers both a base unitand modular chip that is inserted to provide flexibility when inputsignals vary from one sensor to another, plus a common base type.This is the most cost-effective way to maintain a factory-wide systemor multiple application needs.
ESM CONTROLLERS offer universal input capabilities with a 4-digitdisplay for both process and set points. The plug-in module chipdesign allows for the configuration of one or two input channels forthermocouples, 2- or 3-wire RTDs or analog 0-5 V, 0-50 V, 0-10 V or4-20 mA. This chip array allows for more than 150 possibleconfigurations from the same base controller. ESM Controllersfeature programmable ON/OFF, P, PI, PD and PID control forms andautomatic or manual operation within the base controller. There areheating, cooling and alarm functions and ramp, soak and assuredsoak settings. Standard RS232 with optional RS485 serialcommunication connection allows for PC interfacing or networking.
ESM INDICATORS are not designed to maintain (control) a process but can be used as high-limit alarm units by virtueof a programmable latch feature. Otherwise, these Indicators offer many of the features of the ESM Controllers. Theseindicators offer dual or multi-point calibration for Volt and mA inputs. There can be up to three output channels and twolevels of password protection. All Indicators offer the same module chip design.
EZM TIMER/COUNTERS have two 6-digit displays: red for the actual count and green for either of the two set points.They will accept input signals from NPN, PNP, Encoder or Dry Contact with reset, pause and channel A and channel Bcounter inputs. Programmable counter/totalizer counter, batch counter, timer, chronometer, frequency meter andtachometer functions are all offered within the same model. Programmable time range is from 0.01 second to 999.99hours, with programmable alarm functions. All Timer/Counters offer the same module chip design.
ESM and EZM Series Controllers
AC
ESM and EZM Series Specifications
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
AC-2 © Copyright Madison Company – 5/08
ESM Controller Family:• 4-digit process and 4-digit set point displays• Plug-in input and output module chips• Universal process input: Thermocouple, RTD, V, mA• Dual- and multi-point calibration for V and mA inputs• Programmable ON/OFF, P, PI, PD and PID control forms• Autotune and Selftune selection• Automatic or manual operation
Model**
ESM4450ESM7750ESM9450ESM9950
Size
1.89” x 1.89” (48 x 48mm)2.83” x 2.83” (72 x 72mm)1.89” x 3.78” (48 x 96mm)3.78” x 3.78” (96 x 96mm)
Base Part Number
ESM4450-12011/0000ESM7750-12011/0000ESM9450-12011/0000ESM9950-12011/0000
EZM ProgrammableTimer/Counter Family:
• Two 6-digit displays: one for actualcount, one for up to two set points
• Reset, pause and channel A and B inputs• Input signals from NPN, PNP, Encoder or Dry Contact• Programmable counter/totalizer counter, batch counter, timer,
chronometer, frequency meter and tachometer functions• Programmable time range from 0.01 sec. to 999.99 hours• Automatic and manual resets• Programmable alarm functions
• Counting functions are selectable: INC, DEC, INC/INC,INC/DEC or UP/DOWN; x1/x2/x4 with Encoder type of counting
• Coefficient and decimal point position to precisely scale input(eg. feet/min., gal./hr., etc.)
• Password protection• Standard RS232 or optional RS485 serial interface port• On-board sensor power supply
Model**
EZM4450EZM4950EZM7750EZM9950
Size
1.89” x 1.89” x 4.13” (48 x 48 x 105mm), 1/16 DIN1.89” x 3.78” x 2.99” (48 x 96 x 76mm), 1/8 DIN2.83” x 2.83” x 2.99” (72 x 72 x 76mm), 1/8 DIN3.78” x 3.78” x 2.99” (96 x 96 x 76mm), 1/4 DIN
Base Part Number
EZM4450-10010/0000EZM4950-10010/0000EZM7750-10010/0000EZM9950-10010/0000
Module Chips:Relay Output*SSR Output (15-18 VDC)Transistor OutputVolt / Current Out (0/4-20 mA, 0-10 V)
Digital Input (5-30 VDC)0/4-20 mA Current Input0-5 A AC Current InputThermocouple Input (Type J, K, T, R, S, B, E, N or C)RTD Input
**Base Size: 4xxx
EMO400EMO410EMO420EMO430
EMI400EMI410EMI420EMI430EMI440
7xxx
EMO700EMO710EMO720EMO730
EMI700EMI710EMI720EMI730EMI740
9xxx
EMO900EMO910EMO920EMO930
EMI900EMI910EMI920EMI930EMI940
* Relay Outputs: 3 A @ 250 VAC for EMO400;5 A @ 250 VAC for EMO700 and EMO900
** Base Size is Model Number Type
• Heating, cooling and alarm functions• Ramp, soak and assured soak settings• Standard RS232 or optional RS485 serial interface port
ESM Indicator Family:• Large 0.80” (20.3mm) high 4-digit display (on ESM4900)• Plug-in output module chips • Universal process input: Thermocouple, RTD, V, mA• Dual- and multi-point calibration for V and mA inputs• Cold dual- and multi-point calibration for V and mA inputs• Junction compensation• Adjustable input filtering, 0.0 to 900.0 seconds
Model**
ESM4400ESM4900ESM7700ESM9900
Size
1.57” x 1.89” (40 x 48mm)3.78” x 1.89” (96 x 48mm)2.83” x 2.83” (72 x 72mm)3.78” x 3.78” (96 x 96mm)
Base Part Number
ESM4400-12011/0000ESM4900-12011/0000ESM7700-12011/0000ESM9900-12011/0000
• Up to three outputs• Password protection at two levels• Standard RS232 or optional RS485 serial interface port
AC
R SeriesR1 General-Purpose Relay
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 7/09 AC-3
Features
R1 General-Purpose Relay
Madison Company offers a full range of relays forcustom applications. Our engineers are available to review customers’ specifications and suggest the proper relay for their application.
This DPDT relay device provides electrical isolation for all Madison single-level and multi-levelswitches. Multi-level switches typically require one relay per level. Relay coils are available for110 VAC, 220 VAC or 12 VDC applications. Theisolated output contacts can be used to switch awide variety of voltages. The relay can be used forsolenoid valves, pumps and alarm applications thatdo not exceed the listed output contact ratings. The30 amp load rating can eliminate the need for apump motor starter in some applications.
Terminal Configuration (switch protection)
1. Apply the input power through the Float Switch and attach to terminals 1 and 0 as shown.
2. Connect one line of the switched power to pin 8. Connect the other power lead through the switched device and to the desired operationterminal (pin 6 or 7).
Switched Terminals
7 Normally Closed 3 Normally Closed6 Normally Open 2 Normally Open8 Common (6-7) 4 Common (2-3)
Output Contact Ratings
(8-6, 8-7 or 4-2, 4-3)30A @ 277 VAC20A @ 28 VDC
1 Hp @ 120 VAC3 Hp @ 240 VAC
• DPDT switching capability
• Control compressor loads to 3.5 tons,25.3 FLA, 110 LRA
• Extended life: > 300,000 operations @ 30A, 240 VAC (DC coil)> 100,000 operations @ 30A, 240 VAC (AC coil)
• Meets UL873, UL508 and VDE 8mmspacing requirements
• UL Class F construction; UL approved for 600 VAC switching
• Conforms to VDE 0435, 0631 & 0700
6
8
7
1
2
4
3
0
115 VAC
V+ -
Pump / Valve
AC
Specifications
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
AC-4 © Copyright Madison Company – 7/09
Electrical: Contact Ratings – @ 25˚C (77˚F) with relay properly vented.
Maximum Load Ratings –Normally Open Contacts:
40A @ 277 VAC, resistive; 6K Ops. (Flange Mount);
30A @ 120/277 VAC, resistive; 10A @ 600 VAC, resistive;
1 Hp @ 120 VAC, 3 Hp @ 240 VAC;
1.5 Hp @ 480 VAC, 1.5 Hp @ 600 VAC;
110 LRA, 25.3 FLA @ 240 VAC with DC coil*;
60 LRA, 14 FLA @ 240 VAC with AC coil;
3A @ 240 VAC pilot duty; 20A @ 28 VDC; TV10 @ 120 VAC
VDE Rating (Flange Mount): 25A @ 400 VAC, 30K Ops.
Normally Closed Contacts:
3A @ 28 VDC or 277 VAC, 2A @ 480 VAC, 1A @ 600 VAC
VDE Rating: 3A @ 400 VAC, 30K Ops.
Minimum Load Ratings –Normally Open Contacts: 500 mA @ 12 VAC/VDC
Normally Closed Contacts: 100 mA @ 6 VAC/VDC
Expected Mechanical Life – 5 million operations
Expected Electrical Life – 100,000 operations at rated load
ARI 780-86 Endurance Test (section 6.6) – HVAC Definite
Purpose Contactor Standard
Normally Open Contacts:
Single Phase/Two Pole (Both poles together switching a single load)
100 LRA, 25.3 FLA, 200K operations (DC Coil)
Single Phase Per Pole (Single load per pole)
110 LRA, 18 FLA, 200K operations (DC Coil)
60 LRA, 14 FLA, 200K operations (AC Coil)
Initial Dielectric Strength: Between Contacts & Coil – 4,000 V rms, 50/60 Hz.
Between Open Contacts – 1,500 V rms, 50/60 Hz.
Between Poles – 2,000 V rms, 50/60 Hz.
Initial Insulation Resistance: Between Mutually Insulated Elements – 109 ohm min. @ 500 VDC
Coil: Voltage – 12 VDC, 120 VAC and 220 VAC
Nominal Power – AC Coil: 4.0 VA; DC Coil: 1.7 W
Coil Temp. Rise – 35˚C/W (95˚F/W)
Maximum Coil Temp. – 155˚C (311˚F)
Duty Cycle – Continuous
Operational: Must Operate Voltage –
AC Coil: 80% of nominal voltage or less
DC Coil: 75% of nominal voltage or less
Must Release Voltage – 10% of nominal voltage or more
Initial Operate Time** – 15 ms typical (25 ms max. w/ bounce)
Initial Release Time** – 10 ms typical (25 ms max. w/ bounce)
Maximum Operating Frequency – 14 operations per minute
Environmental: Temperature Range –
Storage: -55˚C to 155˚C (-67˚F to 311˚F)
Operating: AC Coil: -40˚C to 65˚C (-40˚F to 149˚F)
DC Coil: -40˚C to 85˚C (-40˚F to 185˚F)
Vibration – 0.065” (1.65mm) double amplitude for
10-55 Hz., functional
Shock, Operational – 10g for 11 ms, 1/2 sine wave pulse
with no contact opening > 100 ms
Mechanical: Termination – 0.25” (6.35mm) quick connects for coil
and contacts
Enclosure – Immersion cleanable, plastic
Weight – Approx. 3 oz. (86 g)
Conditions: All parametric, environmental and life tests are performed
according to EIA Standard RS-407-A at standard test
conditions (25˚C ambient, 20-50% RH, 29.5 ± 1” Hg.), unless
otherwise noted.
* FLA and LRA ratings are compatible with 3.5 ton
compressor applications
** Nominal voltage, no coil suppression, excluding bounce
AC
R SeriesR2 Controllers
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 6/09 AC-5
Features
• Dual probe level detection
• Solid state circuitry, coated for moisture protection
• Factory-fixed or adjustable sense resistance
• UL and CSA approvals
• Electromechanical relay output for isolation and reliability
R2-120 Liquid Level Controller
The R2-type liquid level controllers provide high-level,low-level or bilevel control in a convenient octal plug-inpackage. Models are available for pump-up or pump-down operation. Transformer isolated AC voltage on theprobes prevents electrolytic plating. Less than 1/1000of an amp of current is used to sense the presence ofconductive liquid between the probes and common.Onboard sensitivity-adjustable units eliminate falsetripping caused by floating debris and foaming agents.Isolated electromechanical relay contacts can be directlyconnected to the control circuitry or control pumps andsolenoids. The R2-type controllers can be used at adistance of up to 500 feet from probes, and twisted pairor shielded cable is recommended.
Typical Controller Hookup to Switches
1. Set switches “Normally Open.”
2. Connect Upper switch to pins 5 and 8, Lower switch to pins 5 and 6.
3. Connect the switched voltage to terminal 1 (AC or DC Volts).
4. FOR PUMP-UP: Connect one end of the pump/valve to terminal 4 andthe other end to the switched voltage return.FOR PUMP-DOWN: Connect one end of the pump/valve to terminal 3and the other end to the switched voltage return.
5. Connect line voltage to terminals 2 and 7.
AC
Specifications
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
AC-6 © Copyright Madison Company – 6/09
Control
Sensing Type
Voltage at Probe Terminals
Sensing Resistance
Sensing ResistanceTolerance
ON/OFF resistance
12 VAC nominal
Factory-fixed or adjustable to 100,000 ohms
Factory-fixed – ±10%; adjustable – guaranteed range
R2-24 – 24 VACR2-120 – 120 VACR2-220 – 220 VAC
±15% nominal
50/60 Hertz
Output
Type
Contact
Output Contact Ratings (1-3 or 1-4)
Socket Rating
Electromechanical relay
SPDT isolated
5A @ 220 VAC 10A @ 120 VAC 10A @ 30 VDC
10A @ 300 VAC
Transient Protection – Dielectric Breakdown: 1500 volts RMS minimum
Environmental – -20˚C to 60˚C Operating Temperature
Mechanical – Plug-in Mounting: DIN-type track mount/surface mount, 8-pin socket termination: Octal 8-pin plug
Mounting Connection – Two molded thru holes for mounting with #8 screws or bolts; can be DIN rail-mounted
Dimensions
Controller
Socket
Total Installed Height
1-3/4” x 2-3/8” x 2-3/4”
1-9/16” x 2” x 11/16”
3-11/16”
AC
Operating Voltage (Input)
Voltage
Tolerance
Frequency
PD SeriesPD765 Trident Meter
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 AC-7
Features
• Current, voltage, thermocouple and RTD inputs
• Shallow depth case, 3.6” behind panel
• NEMA 4X, IP65 front
• Universal Power Supply: 85-265 VAC or 90-265 VDC
• Two-relay output
• Process and temperature
• High and low alarms
• Latching or non-latching relays
• Pump alternation control
• Time delay and fail-safe relays
• Maximum and minimum readings
• Easy four-button programming and setup with lockout capability
• Display: 4 digits (-1999 to 9999), 0.56” high
• Linear or square root function with low-flow cutoff
• Optional plastic, steel and stainless steel NEMA 4 and 4X boxes
Model PD765
The Madison Model PD765 Trident Meter is aUniversal Panel Meter that handles all of thecommon process display applications withsimplicity, reliability, accuracy and ease. It isfactory calibrated to accept process voltage andcurrent inputs, 100 ohm platinum RTDs and thefour most common thermocouples. Setup andprogramming are a jumper-free, single-switchsnap using a simple four-button programmingmethod or a computer. If there are multiplemeters to be programmed, the Trident’s copycapability allows one meter’s setup to beautomatically copied to another.
AC
PD765 Available Options
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
AC-8 © Copyright Madison Company – 5/08
4-20 mA Analog Output option
24 VDC @ 200 mA Transmitter Power option
RS-232, RS-422/485 Serial Communication options
Data Acquisition with MeterView® software
Meter Copy feature
Optional Plastic, Steel and Stainless Steel NEMA 4 and 4X Boxes
2.45"(62.2)
0.59"(15.0) 3.6"
(91.4)
3.2"(81.3)
1.76" (44.7)
2.50"(63.5)
4.68”(118.9)
3.61"(91.7)
Side View Top View
AC
ED SeriesLoop Powered Displays
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 4/09 AC-9
Features
Model ED-001 Loop Powered Probe-Mount Display – Plastic Housing
Model ED-002 (not shown) –Metal Housing
For use with most Ultrasonic andRadar Sensor models
Model ED-003 Loop Powered Wall-Mount Display
For use with any Level Switch with a4-20 mA output, and with Ultrasonic orRadar Sensor models
• For use with tanks whose level isbeing monitored by a sensor witha 4-20 mA output
• Indicates the percentage full or empty
• Display can be changed to indicate100% at 4 mA or 20 mA by simplymoving an internal link
• Packaged in a compact NEMA 4X enclosure that can be wallmounted (ED-003) or probe mounted(ED-001 or ED-002)
AC
ED-003 Specifications
All specifications are subject to change without notice.
Sensor solutions for today and the future™
Madison Company 800-466-5383 www.madisonco.com27 Business Park Drive, Branford, CT 06405 • 203-488-4477 • Fax: 203-481-5036 • E-mail: [email protected] Europe – Phone: + 31 (0) 548 659 034 • Fax: + 31 (0) 548 659 010 • E-mail: [email protected]
AC-10 © Copyright Madison Company – 4/09
Display – 3 digit LCD 1/2” (12.7mm) high
Temperature – -40˚C to 60˚C (-40˚F to 140˚F)
Voltage Drop – 0.95V @ 20 mA
Accuracy – Reading ±0.5%
Humidity – 0-95% non-condensing
Range – 3.5 mA to 22 mA
Maximum Current – 150 mA
Display Range – Normal 100% @ 20 mA -3% to +112%0% @ 4 mA
Reverse 100% @ 4 mA -12% to +113%0% @ 20 mA
22 mA and Above – LOE (Loss of Echo)
Wall-Mounted Enclosure – NEMA 4X, IP65
LOOP POWERED DISPLAY
20
%
4
++
+ +
3.54"(89.9)
2.37"(60.2)
4.53"(115.1)
4.05"(102.9)
ø0.172" Typ. of4 Mtg. Holes
Front View
0.24"(6.1)
AC
The first consideration is the type of liquid, temperature and pressure to which the switch will be subjected. Madisonmanufactures liquid level switches in various styles, in a variety of materials, to cover a broad range of conditions.Following are some basic recommendations for selecting the proper liquid level switch material for your application.
Material
316 Stainless Steel
Polypropylene (PP)
Polysulfone (PSU)
Brass
Buna-N (Nitrile)
PBT(PolybutyleneTerephthalate)
Kynar
PTFE (Teflon®)
Application
For high-temperature (to 300˚C), high-pressure (to 300 PSIG) and corrosive conditions.Commonly used in food processing, medical, heating and cooling equipment.
For acidic conditions, such as found in electroplating and metal cleaning. Another choice forlower-temperature (to 105˚C) food processing applications (Madison Company uses onlypolypropylene that is FDA-approved for food contact). Also a good choice for general-purpose applications in commercial or consumer appliances and equipment.
A hydrolysis-resistant material for continuous use in hot water and steam, at temperaturesup to 148˚C. High chemical resistance to acidic and salty solutions and good resistance todetergents. Commonly used for analytical instrumentation, medical devices andsemiconductor process equipment components. Food-grade material available with FDA,NSF, 3A-Dairy and USP Class VI compliance, upon request.
The selection for petroleum-based liquids, such as lubricating oils, gasoline and diesel fuels.Widely used in storage tanks of vehicles, generators, transmissions and hydraulic systems.Other uses are in lubrication, recovery, refining and fuel processing equipment withtemperatures up to 130˚C.
Suitable for use with aromatic hydrocarbons, dilute acids and bases with a temperature rangeof -50˚C to 120˚C. Applications include fuel tanks, transmissions and hydraulic systems.
A strong and highly crystaline plastic featuring good dimensional stability. Generally serveswhere temperature resistance and permeability are not important. Ideal for applicationssuch as fuel and hydraulic systems with continuous service at 120˚C.Please note: PBT is not suitable for use in temperatures above 130°C.
Chemical- and solvent-resistant properties make this material a problem solver for manyapplications. Its high purity nature is ideal for food handling and sensitive laboratory or testequipment with temperatures up to 105˚C.
This material is ideal for acids, alkalis, oils and gasoline applications where temperaturesare up to 260˚C. Temperature-stable and chemical-resistant, with a very low coefficient of friction.
Environmental Considerations
Madison Company also manufactures selected switch models in a combination of materials that are available fromstock or in a custom, build-to-order configuration.
Once a suitable material has been selected, the type of switch and configuration of actuation points, fittings and wireterminations are the next considerations. Madison Company stocks a full line of standard products that can meet therequirements of many applications. For specific designs, Madison can custom build, to order, switches with an infinitenumber of variations and options.
Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
Material Selection Guide
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-1
RF
Mat
eria
l Typ
e
316
Sta
inle
ss S
teel
Bra
ss &
Bu
na-
N
PB
T &
Bu
na-
N
Kyn
ar
Po
lyp
rop
ylen
e
PB
T (
Po
lybu
tyle
ne
Tere
ph
thal
ate)
N/A
- N
ot
Ava
ilab
leS
losh
Sh
ield
s fo
r tu
rbu
len
ce p
rote
ctio
n a
vaila
ble
on
mo
st s
wit
ches
.O
ther
mat
eria
l co
mb
inat
ion
s, s
ub
mer
sib
les
and
sp
ecia
lty
swit
ches
are
ava
ilab
le.
Typ
ical
Ap
plic
atio
ns
Hig
h t
emp
erat
ure
Hig
h p
ress
ure
Co
rro
sive
co
nd
itio
ns
Lu
bri
cati
ng
oils
Hyd
rau
lic f
luid
sG
aso
line
and
die
sel f
uel
s
All
pla
stic
Lu
bri
cati
ng
oils
H
ydra
ulic
flu
ids
Gas
olin
e an
d d
iese
l fu
els
Ch
emic
al r
esis
tan
tH
igh
pu
rity
ap
plic
atio
ns
Gen
eral
pu
rpo
seF
DA
ap
pro
ved
fo
r fo
od
use
Aci
dic
co
nd
itio
ns
All
pla
stic
Lu
bri
cati
ng
oils
Hyd
rau
lic f
luid
sG
aso
line
and
die
sel f
uel
s
Mo
un
tin
g:
Bu
ild t
o O
rder
Sid
e M
ou
nt
Fu
ll-S
ize
Flo
at
Ver
tica
l Mo
un
t
Sin
gle
Th
read
M50
10M
5970
M40
10
N/A
M97
50
M87
50M
8790
M87
25
M77
50M
7790
M77
25
Du
alT
hre
ad
M59
00M
5910
M59
20
N/A
N/A
M97
00
M87
00M
8740
M77
00M
7740
Sta
nd
ard
Sw
itch
M56
00M
5917
(oth
ers)
M43
00(o
ther
s)
M78
00(o
ther
s)
M98
00
M88
00(o
ther
s)
N/A
Po
wer
Ree
dS
wit
ch
M56
00P
R(o
ther
s)
N/A
N/A
N/A
M88
00P
R(o
ther
s)
N/A
Min
iatu
reF
loat
M50
00(o
ther
s)
M45
00(o
ther
s)
M70
00
M90
00
M80
00(o
ther
s)
N/A
Su
bm
inia
ture
Sw
itch
N/A
N/A
N/A
N/A
M33
26
N/A
Mu
lti-
Lev
elS
wit
ch
M56
02M
5002
(w/ o
pti
on
s)
M43
02M
4502
(w/ o
pti
on
s)
N/A
M98
02M
9090
(w/ o
pti
on
s)
M88
02M
8080
(w/ o
pti
on
s)
N/A
IN S
TOC
K
Sel
ecte
d S
wit
ches
Mad
iso
n C
om
pan
y •
(203
) 48
8-44
77
•(8
00)
466-
5383
•
Fax
(203
) 48
1-50
36
•in
fo@
mad
iso
nco
.co
m
•w
ww
.mad
iso
nco
.co
m
RF-2 © Copyright Madison Company – 2/05
General Product Guide
RF
Intensive agitation of liquid, boiling fluids and surging due tolarge inflows of liquid can all cause tur bu lence and erraticfloat switch operation. This problem can be eliminated by theuse of slosh shields with adequately-sized fluid and ventholes, as il lus trat ed here. Available for vertical, horizontal(side-mounted) and multi-level switches with full-size orminiature floats, these slosh shields can be sup plied in stain less steel, brass, polypropylene, PBT or Kynar.
Turbulence
Every Madison float switch has a float containing a magnet and a dry reed switch encapsulated within a stem. Thefloat travel in the liquid magnetically actuates the reed switch, providing an “on” or “off ” function.
NORMALLY CLOSEDNORMALLY OPEN
Operation (NO/NC)
Every Madison float switch contains a dry reed switch encapsulated within a stem. Reed switches are highly reliableand able to deliver more than 5 million switching cycles when operated at their rated electrical load. To ensure manyyears of operation, it is important to consider the electrical load conditions to which the switch will be subjected.
All reed switches are rated for resistive loads or steady state current. Devices such as motors, solenoids, coils, strobesor tungsten lights are capable of producing a capacitive or inductive electrical load. When power is applied or removed,these devices can produce a current spike that is four to ten times the steady state current. The resulting exposure tohigh current can burn the reed switch contacts or fuse the reeds together, causing a shortened switch life or failure.
We recommend that a circuit be used to protect a reed switch from current overload caused by a capacitive orinductive device. The commonly-used circuits shown below will allow the switch to function while preventing highcurrent from damaging the reed switch contacts.
–+
Ind. Load
DC Contact Protection/Load Drain
1N4004
Note: For AC loads, the diode can be replaced with a varistor.
–+
Ind. Load
Reed Protection
V
R
Is
Lamp Loads
Switch operation is determined while the switch is inthe dry position with the installation fitting up.
Normally Closed: Switch will open on the rise ofliquid and close on the fall of liquid.
Normally Open: Switch will close on the rise ofliquid and open on the fall of liquid.
Madison switches are supplied in the normallyclosed (NC) position, unless otherwise specified.
Reed Contact Protection
R = Current limiting resistor("R" should be selected to give "Is" less than the rated carrying current.)
L
Float Switch Technology
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-3
RF
Madison has extensive experience in the design and production of tank levelcontrols. Level switches with two or more floats are often used as part of a controlsystem for pumps and other filling devices. For single-phase devices, such assolenoids and pumps with fractional horsepower motors, a single relay circuit maybe incorporated in an enclosure for either filling or draining operations. For largerpumps, where three-phase operation is required, the same relay circuit can beused to control the three-phase contactor in the motor control circuit. ConsultMadison's fluid control engineers for assistance with these applications. Typicalcircuits for this type of control are illustrated here.
TopSwitch
BottomSwitch
Relay
Relay
Single Phase Pump Motoror 3-Phase Contactor Coil
or Solenoid Valve
B
BottomSwitch
TopSwitch
Relay
Relay
Single Phase Pump Motoror 3-Phase Contactor Coil
or Solenoid Valve
F
Electrical Considerations for Reed Switch Devices
For Pump-Up Applications
For Pump-Down Applications
Electrical current overload is a common cause of failure for liquid level switches utilizing reed switch technology. Reedswitches are rated for a steady-state current. Devices such as motors, solenoids or coils can produce capacitive orinductive electrical loads. When power is applied or removed from these devices, it can produce a current spike from 4 to 10 times the switch’s steady-state current. This spike in the current can arc across the contacts of the reed switch,causing the contacts to fuse together or stick. When this occurs, the switch may fail or appear unreliable. To preventthis type of failure, a circuit can be wired in conjunction with the switch to protect it from the current overload causedby capacitive or inductive devices. A resistor/capacitor network or varistor can be used for AC loads, and a diode canbe used for DC loads.
cable capacitance
R
load
load
load
diod
e
+
-
load
R
C
varistor (VDR)
Capacitive Load
Inductive Load
When trying to switch loads (capacitive orinductive) that exceed the maximum steady-state current rating of the reed switch (see UL Current & Voltage Rating Chart onfollowing page), Madison recommends the use of general-purpose/isolation relays orcontrollers to protect the switch from currentoverload. This will prevent the contact of thereed switch from fusing together, therebyincreasing the lifespan and reliability of theswitch. Madison offers the R1 general-purpose DPDT relay for switching simpleloads, as well as the R2 controller to performpump-up or pump-down control when usedwith at least two levels. Keep in mind that anyrelay or controller that you use should berated to handle your supply voltage and havea current rating greater than your maximumsupply current.
The life of the reed switch istypically 10 6 - 10 9 operations,dependent upon loadconditions. The special reedblade material is selected toensure a mechanical life of atleast 3 x 10 9 operations.
Contact Protection: Thespecified value of switchingcurrent and/or voltage mustnever be exceeded, even forvery short periods. It isstrongly recommended thatcontact protection be usedwhenever there are capacitiveor inductive loads (long leadsand relay loads). High inrushloads caused by filamentlamp switching orcapacitances may becompensated for by usingcurrent limiting resistors.These should limit the currentto that acceptable to the reedswitch.
Tank Level Control
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-4 © Copyright Madison Company – 2/05
Electrical Data
RF
Nominal VA
360
100
60
30
25
15
Amperes(resistive)at 240 VAC
1.50
0.40
0.40
0.14
–
–
Amperes(resistive)at 120 VAC
3.00
1.00
0.50
0.28
0.28
0.12
Amperes(resistive)at 120 VDC
0.75
0.40
0.20
0.07
–
100 VDC / 0.10
Amperes(resistive)at 24 VDC
3.00
1.00
0.50
0.28
0.28
0.30
Amperes(resistive)at 12 VDC
3.00
2.00
0.70
0.56
0.28
0.30
MadisonCalculation
UL Rating of Level Switch
Current & Voltage Rating of Liquid Level Switches
Above ratings are for resistive loads only.Maximum voltage ratings: SPST Switches – 240 VAC; SPDT Switches – 120 VAC
Please note: Nominal VA is Volts x Amps and is the term used for Apparent Power in AC circuits. It is simply the product ofvoltage and current, without taking into account the type of load (resistive or inductive). In this chart we use the Nominal VAwith resistive load in conjunction with the applied AC voltage to determine the current – we are stating currents with aresistive load. Watts and VA can be used interchangeably in the charts above.
We recommend that switches stay below these ratings for non-resistive loads.
Current and Voltage ratings are for resistive loads only. For inductive loads, maximum life will be achieved ifappropriate arc suppression is used.Maximum voltage ratings: SPST Switches — 240 VAC
SPDT Switches — 120 VAC
Each switch has a power rating in watts. These power ratings are for resistive loads that are at a steadystate and are calculated as Power (Watts) = Voltage (AC/DC) * Current (Amps-resistive load). Most deviceshave other things to consider, such as current or voltage spikes caused when powering up or shuttingdown. Common devices such as pumps, coils and light bulbs can create these types of spikes. For thesemore complex cases, one must remember to stay within the maximum current and voltage ratings of theswitch regardless of the power rating.
For example, our 30-watt standard switches have a maximum switching current of 1 Amp and a carryingcurrent of 2.5 Amps. If the switch is connected to a 12 V circuit that spikes to 2 Amps and runs at a steadystate of 1 Amp, the power spike exceeds the switch rating although the steady state running power is 12 Watts. Due to the heat and type of power dissipated during the spike, the contact may be damaged or even welded together, causing switch failure.
Custom designs have other elements to consider and even alternative ground paths that may affect thepower delivered to a switch. It is important to consult your engineering department before assuming thesystem's power requirements. Contact the factory for additional assistance.
Electrical Data
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 5/07 RF-5
RF
Wire Color Guide
Wire Colors forStandard Switches
Wire Colors for Full-Size Multi-Point Switches with SPDT Switches
Note: Maximum of four levels with SPDT switchesWireColor
White
Black
Yellow
Brown
Red
Switch Materialor Model No.
Polypropylene
Stainless Steel,Brass/Buna-N, PBT
Kynar
M3326
M3326-NO
Number ofSwitches
1
2
3
4
Color Code(Top to Bottom)
C - Black, NO - Green, NC - Yellow
C - Blue, NO - White, NC - RedC - Black, NO - Green, NC - Yellow
C - Blue, NO - White, NC - RedC - Brown, NO - Orange, NC - VioletC - Black, NO - Green, NC - Yellow
C - Blue, NO - White, NC - RedC - Brown, NO - Orange, NC - VioletC - Grey, NO - Red/White, NC Yellow/WhiteC - Black, NO - Green, NC - Yellow
Note: Custom colors are available at customer request.
Wire Colors forFull-Size and Miniature
Multi-Level Switcheswith SPST Switches
Number of Switches
2
3
4
5
6
Color Code (Top to Bottom)
RedBlack
RedWhiteBlack
RedWhiteBlueBlack
RedWhiteBlue
GreenBlack
RedWhiteBlue
GreenYellowBlack
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-6 © Copyright Madison Company – 5/07
Electrical Data
RF
Pipe Plug Flange Male Thread Bulkhead
Madison multi-pointswitches are available withbulkhead, male thread,male pipe plug or flangemounting. These switchesmay be mounted with thestem at up to a 30° anglefrom the vertical position.
Obstructions in tanks anddifficult mountings oftenrequire bending the tube toallow proper installation.Madison's engineering staffcan design switches withoffset stems to solve manytypes of installation problems.All metal stems are availablewith offset configurations.
Typical Installation Fittings
Offset Stems
Switch Fittings and Stems
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-7
RF
Many Madison switches can be furnished inadjustable form, permitting installationpersonnel to set any desired level of switchactuation. A male pipe plug with integralcompression fitting is installed in the tank. Thetube containing the reed switch can then beadjusted to actuate at any desired level. Allmetal multi-point switches are available withthe adjustable feature.
Mounting Plug
Compression Fittingfor Adjusting Length
1/2" NPTConduit Connector
Adjustable Liquid Level Switches
Madison Company uses special floats, stems, fittings and construction techniques to produce levelswitches which will operate properly under conditions of severely high pressure. Two high pressureranges are available: HP (750 PSIG maximum) and VHP (1500 PSIG maximum).
The M5602 switch with 2” NPT pipe plug mounting is available for use under high-pressure conditions.
High-Pressure Applications
Multi-Point Switch Set Up Criteria
Special OptionsPlease consult factory concerning available options such as the following:
• TERMINATIONS • TEMPERATURE SENSORS • OTHER FITTINGS • ADJUSTABLE FITTINGS• OFFSET SWITCHES • JUNCTION BOXES • EXTRA CABLE LENGTHS • CABLE • FLOATS • PLASTIC COLORS
For M5002, M5042, M8080*, M8002, M8042, M4402, M4502
L (Total) = L4 + 1” (25.4mm) Min.
Distance from mounting fitting to first switch = 3/4” (19mm) Min.
Minimum distance between floats:1-1/2” (38.1mm) / 1-3/4” (44.4mm) for M8080
Minimum LH = 1-1/2” (38.1mm)
Not applicable for M8080*
* Note: 3 levels maximum on model M8080.
For M8802
L (Total) = L5 + 2” (50.8mm) Min.
Distance from mounting fitting to first switch = 1-3/4” (44.4mm) Min.
Minimum distance between floats: 3” (76.2mm)
For M5602, M5402, M8602, M8402, M4602, M4302
L (Total) = L5 + 1-1/2” (38.1mm) Min.
Distance from mounting fitting to firstswitch = 1-1/4” (31.7mm) Min.
Minimum distance between floats: 2-1/2” (63.5mm)
Minimum LH = 2-1/2” (63.5mm)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-8 © Copyright Madison Company – 10/07
Multi-Point Switches
RF
Frequently-Asked Questions
1. How can I connect my float level switch to a pump or valve while protecting it from the highcurrent that these devices use?
In most applications, a relay is required to isolate the float switch from the device. The float switch will be connected in series with a relay input coil that typically draws less than 500 mA.When the switch is closed, the relay coil is activated and closes the output contacts. Thesecontacts turn on or off the high current required by the device.
1a. How can I control my pump to maintain a range of fluid in my application?
Madison offers several solutions to control fluid levels in custom applications. The most common isby using a Double Pole Double Throw (DPDT) relay combined with a custom two-level float switchor two independent Normally Open float switches placed at the levels to turn the pump on and off.
The diagrams shown on the fourth page of this Reference section illustrate typical circuits for these“pump-up” or “pump-down” applications.
Madison also stocks an R2 pump controller that can be used with float switches or conductivityprobes. Madison stocks relays and controllers to activate pumps, solenoid valves, motors andalarms. Our fluid control engineers are on-hand to assist you with these applications.
2. How can I tell if my switch is set for Normally Open (NO) or Normally Closed (NC) operation?How can I change from NO to NC (or vice versa)?
Each style switch is equipped with a means to identify the type of operation to which the switch is set.
Vertical: NO/NC operation is indicated by the position of the witness mark (stainless steel models)or magnets (plastic models). NO is indicated by circle up (stainless steel) or magnets down plastic); NC is indicated by circle down (stainless steel) or magnets up (plastic).
Horizontal: NO/NC operation is indicated by the direction of the arrow on the hex. NO is indicatedby arrow up; NC is indicated by arrow down. An ohmmeter or continuity meter can be used toverify the switch setting and operation. Simply connect the meter to the leads and, with the floathanging down away from the fitting, measure the switch. If the meter reads a short, then the switchis normally closed and will open on rise.
All switches are shipped in the Normally Closed (NC) position, unless otherwise specified. Tochange the contact operation, simply remove the retaining ring and float and reverse the float onthe stem. The only exception to this is the subminiature switch (M3326/M3326-NO), for whichoperation must be specified when ordered, since the float is not reversible on this switch.
Magnetic Float Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-9
RF
Frequently-Asked Questions
3. Is there a way to sense between two liquids?
Madison can furnish an Interface Float that, given two mediums, is designed to sink in onemedium and float in the other. A typical application would be one where oil and water accumulatein one tank, and sensing of only a fall in water level is required (oil level is not an issue). Since astandard float of any material will float in any liquid with a specific gravity higher than the specificgravity of the float, Madison would “weight” the float to a specific gravity of 0.95. Since the specificgravity of the oil is 0.8-0.9 and that of the water is 1.0, the float will sink in the oil and float in thewater. Both full-size Buna-N and polypropylene floats can be modified in this manner.
4. How do I make sure the switch I choose has the correct specific gravity?
One of the main considerations when choosing a switch is the specific gravity of the float. To makesure the float will function properly in the application, the specific gravity of the fluid must begreater than the float’s specific gravity at the maximum temperature range of the application. Forreference, below are specific gravities of some of our floats.
Full-size floats:Stainless steel — 0.55 SG, except M5600-PR float is 0.70 SGPolypropylene — 0.75 SGBuna-N — 0.45 SGKynar — 0.75 SG
Miniature floats: Stainless steel — 0.70 SGPolypropylene — 0.80 SG, except M3326 is 0.60 SGBuna-N — 0.45 SGKynar — 0.85 SG
Side-mounted floats:M5900 series (stainless steel) — 0.60 SGM5970 — 0.70 SGM5010 — 0.60 SGM4010 — 0.45 SGPolypropylene — 0.60 SGPBT — 0.75 SGKynar — 0.75 SG
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-10 © Copyright Madison Company – 2/08
Magnetic Float Level Sensors
RF
Frequently-Asked Questions
5. Which switch material is best suited for my liquid level application?
316 Stainless Steel: For high-temperature (to 300°C), high-pressure (to 300 PSIG) and corrosiveconditions. Commonly used in food processing, medical, heating and cooling equipment.
Polypropylene & Polysulfone: For acidic conditions, such as found in electroplating and metalcleaning. Another choice for lower-temperature (to 105°C) food processing applications (MadisonCompany uses only polypropylene that is FDA-approved for food contact). Also a good choice forgeneral-purpose applications in commercial or consumer appliances and equipment.
Brass & Buna-N, PBT & Buna-N: The selection for petroleum-based liquids, such as lubricatingoils, gasoline and diesel fuels. Widely used in storage tanks of vehicles, generators, transmissionsand hydraulic systems. Other uses are in lubrication, recovery, refining and fuel processingequipment. PBT is not suitable for use at temperatures above 130°C.
Kynar: Chemical- and solvent-resistant properties make this material a problem solver for many applications. Its high-purity nature is ideal for food handling and sensitive laboratory or test equipment.
6. Can I order directly from Madison, or should I go through a distributor?
Madison products can be ordered direct from the factory. Minimum order is $300. We acceptpayment by credit card (Visa, MasterCard and American Express) or COD. Please contactMadison to set up an account on open terms.
We also have a network of distributors located in various regions across the U.S. and Europe.Please visit www.madisonco.com.
7. How can I ensure that my switch’s performance will not be affected by turbulence?
Turbulence, which can be caused by a vibrating tank, intensive mixer agitation or surging of liquidduring tank filling, can result in premature failure of both the switch and the relay, due to chattering.A very low-cost, reliable solution to this problem is the use of a slosh shield. This device is equippedwith fluid and vent holes and surrounds the switch float to prevent erratic switch operation.
Madison stocks a complete selection of slosh shields for vertical and horizontal switches instainless steel, polypropylene, PBT, brass or Kynar.
8. Can I customize a standard switch?
Madison Company offers a full range of value-added options, including terminations andconnectors; extra-long or -short lead lengths; special cable or wire; shrink tubing for wireprotection; and special sealing materials, such as Viton or Buna-N gaskets and O-rings. We can also meet special requirements with our temperature switches, slosh shields and weather-proof or explosion-proof junction boxes.
Magnetic Float Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-11
RF
Frequently-Asked Questions
9. Which Madison switches are explosion-proof?
Our vertical M5600 series and our horizontal M5900 series are rated explosion-proof by UL andCSA for use in Hazardous Locations, Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class I.These switches are also approved by DEMKO for use in potentially explosive atmospheresEEx d IIC T2 and carry the Ex mark.
10. Are liquid level switches affected by semi-solid particles or magnetic particles in the liquid?
Yes, standard float switches may be affected by these conditions because such particles cancause a float to stick or to not operate at all. Instead, we recommend using a conductivity switch,such as our multi-point model M3784 or single level model M3850. Because our conductivityswitches have no moving parts, operation of these switches is not interrupted. Furthermore, theM3827 side-mounted switch is engineered such that the magnetically actuated reed switch will notcome in contact with the fluid being monitored. The float is attached to an extended pivot arm that,when moved, triggers the switch function. This switch is ideal for use in heavy-bodied liquids or influids containing metal particles that would otherwise be attracted to a conventional style float.
11. What industry ratings do Madison’s switches have?
We have a continuing program to upgrade our list of UL and CSA approvals. Madison Company’sliquid level switches have general-purpose approval as recognized components granted by ULunder file number E54633 and CSA file number LR56150.
Some Madison switches are also NSF-certified for food applications.
In addition, we are self-certified for CE under the following directives:
EN60730-1 — Automatic Electric Controls for Household and Similar Use – Part 1: GeneralRequirements (1995)
EN60730-2 — Automatic Electric Controls for Household and Similar Use – Part 2: ParticularRequirements – Section 2-15: Automatic Electrical Water Level Sensing of the Float or Electrode-Sensor Type used in Boiler Applications (1996)
Low Voltage Directive (72/73/EEC)
Our M5600 and M5900 switches are certified explosion proof by DEMKONo. 99E.126064X EEx d IIC T2: Protected for use in potentially explosive atmospheres.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-12 © Copyright Madison Company – 2/05
Magnetic Float Level Sensors
RF
Frequently-Asked Questions
12. What types of testing do Madison switches undergo?
Madison Company periodically life tests the reed switches used in its liquid level switches. This isdone to ensure that the reed switches, as obtained from our vendors, have not had a shift inoperating characteristics. The reed switches are tested, rather than the complete assembly,because they are the principal electrical component of the liquid level switch.
The testing is performed by cycling the switch, using a standard coil, one million times. The loadon the switch is an incandescent light bulb rated for the maximum wattage of the reed switch (i.e.,a 60-Watt bulb is used to test a reed switch rated at 60 Watts maximum).
A resistive load (light bulb) is used because it provides a uniform standard against whichcomparisons can be made. Inductive loads vary greatly from device to device, making comparativeanalysis very difficult.
The degree of deterioration of a reed switch after life cycle testing is measured by determining thechanges in contact resistance, pull-in force and drop-out force as compared to those samemeasurements made before testing commenced.
Madison Company has the capability of doing life-cycle testing of reed switches using specificelectrical loads, such as relays or solenoids supplied by our customers. Please contact the factoryfor more information.
13. What type of warranty does Madison offer on its sensors? What is the return policy?
Our sensors are warranted for one year from date of manufacture. We only accept returns that areauthorized by the factory. Please contact the Sales Department for a Return Authorization Number.
14. Does Madison offer special packaging and/or labeling?
Yes, we offer a variety of custom packaging — bar coding, special unit packs, etc. Please contactthe factory for more information.
Magnetic Float Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-13
RF
Frequently-Asked Questions
15. How does Madison keep such a large variety of sensors in stock?
In order to better serve our customers, we continually review our Lean Manufacturing techniquesand Kanban systems to meet demands. These systems eliminate both overstocks and stockoutsand allow us to maintain the proper level of inventory for both standard switches and custom fittings.
16. What kind of lead time can I expect once I order my switch? Is there a difference whenordering standard or custom switches?
Standard switches have a lead time of one to two weeks. Custom switches have a three-weeklead time.
17. Can I order a Madison switch with more than one level?
Yes, Madison offers multi-point switches in many configurations. Our full-size multi-point switchescan be set for up to six levels, and our miniature switches can be set for up to four levels. Theycan be mounted within any vessel, utilizing male pipe threads, pipe plugs, flanges or bulkheadfittings. The length of each switch, as well as the location of the floats, can be established by thedesigner. For those users who want to design and install their own systems, multi-point switch kitsare available in three different materials.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-14 © Copyright Madison Company – 2/05
Magnetic Float Level Sensors
RF
Madison’s ultrasonic sensors rely on high-frequency soundwaves above the range of human hearing (over 20,000hertz) to measure level. Our ultrasonic sensors useultrasonic sound waves to sense the level of liquids, solids orpowders in airbased containers, tanks and vessels of allsizes and shapes.
Madison’s sensors can be bench- or field-calibrated throughcommunications with a PC or a push button on the sensor.This capability enables the user to define the span in thevessel and only trigger on objects within that window. Eachstandard model has its defined operating distance listed onthe catalog chart page. Custom models can be designed forspecific application needs based on the variables that can befound on the Madison Specification Work Sheet.
These ultrasonic sensors are not susceptible to error due tothe target material’s color, shape or composition (e.g.,transparent or opaque, liquid or solid). They are particularlygood for applications that must sense a non-metallic object inan environment where there is systematic, heavy wash down, liquid, dust, heavy spray, food, ink, or otherenvironmental hazards. Since sound energy is used for detection, the reflecting object does not have to bemetal, but can also be glass, plastic or even paper.
Stagnant, non-agitated liquids and solids consisting of large and hard particles are good reflectors and, therefore,good candidates for ultrasonic level measurement. Fluff, foam and loose dirt are poor reflectors, and dust, mistor humidity in the vapor space tend to absorb ultrasonic pulse. When these conditions are present, they aregenerally not measurable. As a rule of thumb, use 20% of the stated range of a Standard model to see if it will overcome these conditions. Where these characteristics are present, a Madison radar sensor might be appropriate.
Refer to the Product Data Sheet(s) for specific product operation characteristics, or contact a Madisonrepresentative for further information.
Ultrasonic Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-15
Architecture of an Ultrasonic Level Device
1/2” conduit for wiring
3” NPT thread
1” to 2” NPT on select models
Ultrasonic trandsucer vibrating face
Zero Distance (when communication with a computer is utilized)
Dead Zone / Minimum Range (no measurement in dead zone)
20 mA or 4 mA
Span
4 mA or 20 mA (target)
RF
Ultrasonic Level Sensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-16 © Copyright Madison Company – 10/05
Operation Principle of Ultrasonic Level Devices
An ultrasonic transducer matched to air is stimulated by a pulse transmitter, and it generates a pressure wavethat propagates to a target and then reflects (in similar fashion to a loudspeaker). The reflected wave is receivedby the same transducer, in the receiver mode, and is converted into an electrical signal (as a microphone would).The electrical signal is amplified and processed to find the reflected echo and then calculated to find the distanceto a specific target. Distances to a target are converted linearly to a 4-20 mA current and, optionally, informationabout level measurement is sent via RS232 or RS485 to a PC for processing such functions as diagnostics,programmble set-up and data logging.
PROCESSOR
PULSE RECEIVER
PULSE TRANSMITTER
4-20 mA output RS232/485
communications
Ultrasonic Transducer
Ultrasonic Sensor Still-Pipe Mounting Considerations
Still-Pipe: Use metal or plasticpipe with a smooth inside.
Make sure the transducernozzle does not make physicalcontact with the still-pipe.
Remove all sharp edges.
45˚
No end cut is required for pipes shorterthan 6”. The ID of the pipe must be greaterthan the OD of the transducer nozzle.
If pipe is longer than 6”, a 45˚ cut is required.
If pipe issubmerged inliquid, a vent holeis required.
RF
If a Madison ultrasonic sensor can’t measure the level of your liquid, ourradar sensors can. Madison’s radar sensors can detect the liquid levelunder a layer of airy foam.
Internal piping, deposits on the antenna, multiple reflections or reflections from the wall can all interfere with the proper operation of the radar sensor.
Madison’s radar sensors use improved microwave pulse technology totrack any target material from the tip of its antenna to the bottom of thetank. Their power, pulse widths and sensitivity depend on the distance of the target from the antenna and the dielectric constant of the reflecting material.
Madison’s radar sensors feature “echo marker” signal processing, makingthem among the most technologically advanced pulse radar systems onthe market. This technology will provide a reliable continuous pulseshape unaffected by environmental conditions such as:
The antenna is offered in Polypropylene or an optional high-resistance PTFE (Teflon®) that can help provideresistance to material buildup.
Simple mounting and push-button calibration make for a very easy installation. Calibration can be completed on thebench or in the field by following simple instructions. The sensor can be threaded directly into a 2” NPT metal orplastic flange. Unique application requirements can be described on the Madison Specification Work Sheet, which ourengineering department will use to produce a design that meets your needs.
Refer to the Product Data Sheet(s) for specific product operation characteristics, or contact a Madison representativefor further information.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-17
Radar Level Sensors
Architecture of a Microwave Device
Rod Antenna
Aluminum Enclosurewith 1/2” conduit for wiring
1-1/2” and 2” NPT thread. For 1-1/2” NPT models, a thermal decoupler isavailable for use in high-temperature applications.
Zero Distance
Dead Zone / Minimum Range (no measurement in dead zone)
20 mA or 4 mA
Span
4 mA or 20 mA (target)
• Temperature• Pressure• Vapors
• Steam• Wind• Vacuums
• Methane• CO2
• Condensation
RF
Operation NoteTurning the low dielectric materials operation mode ON or OFF
The ON mode is recommended for materials with a dielectric constant lower than 4 and to eliminate multiplereflections in tanks.
1. To turn the low dielectric materials mode ON, push the calibration button and hold until the LED light flashes yellow,then red, and then turns off. Release the button. The blinking green LED light indicates that the low dielectricmaterials mode is ON.
2. To turn the low dielectric materials mode OFF, push the calibration button and hold until the LED light flashes yellow,then red, then turns off. Release the button. The constant green LED light indicates that the low dielectric materialsmode is OFF.
The low dielectric materials operation can also be turned ON or OFF with Madison’s software during PC communications, which is recommended.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-18 © Copyright Madison Company – 10/05
Radar Level SensorsOperation Principle of Microwave Level Devices
The microwave rod antenna is stimulated by an electromagnetic pulse transmitter and sends very short pulses toa target. The pulses reflect from the target and then they are received back by the same antenna. The electricalsignal from the antenna is amplified and processed. The distance to an object is calculated and then convertedto 4-20 mA. Optionally, level information is also sent to a PC via RS232 or RS485 for diagnostic data logging andprogrammable set-up.
PROCESSOR
PULSE RECEIVER
PULSE TRANSMITTER
4-20 mA output
Microwave Antenna
RS232/485 communications
RF
FCC Information for UsersSensors have been tested and found to comply with the limits for Class A digital device, pursuant to Part15 of the FCC rules. These limits are designed to provide reasonable protection against harmfulinterference when the equipment is operating in a commercial environment. These sensors generate, use,and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause interference with radio communications. Operation of this equipment in a residential area islikely to cause interference that the user will be required to correct.
Radar features: Madison Company’s radar sensors are highly accurate, noiseless and self-adjustingpulse radar transmitters for distances up to 100’. The sensors adjust their microwave pulse amplitude andwidth to a target distance and target reflection properties. The receivers change their sensitivity with theamplitude of received echoes. In addition, the sensors analyze the shapes of the received echoes andeliminate the ones coming from tank walls, standpipes and other obstructions. These features allow thesensors to track any wanted target from the tips of their rod antennas to the bottom of the tank,regardless of the tank shape or environmental conditions. For very low dielectric constant materials (≈2),the radar sensor needs at least 2’ from the antenna tip to detect the material. Any buildup on the rodantennas does not deteriorate the performance of the radar sensors. The radar transmitters do not haveany mismatch between resonator and transceiver. This eliminates problems when a target is close to theantenna and gives optimal performance of the radar sensor’s very high efficiency. The Madison radarsensors also feature a low dielectric mode. In this mode, the Madison sensors will ignore echoes fromtank bottoms with material present, and they will increase their transmit energy and the sensitivity of theirreceivers until they detect echoes from the surfaces of the low dielectric materials. This mode will workwith dielectrics around 2 and higher.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-19
Radar Level SensorsRadar Sensor Still-Pipe Mounting Considerations
If pipe issubmerged inliquid, a vent holeis required.
Remove all sharp edges.
45˚
No end cut is required for the following: End cut of 45˚ is required for pipes longer than 10.5”; the ID of the pipe must be greater than 6”.
Pipe ID
2.0”3.0”
4.0” and 5.0”6.0”
Max. Length
2.5”3.5”6.0”10.5”
RF
The best echo is obtained when the sensor diaphragm is parallel to the surfaceof the material being monitored. Make sure that the material does not encroachinto the dead zone (ultrasonic sensor).
A ball aimer with a 3” NPT thread is available for all ultrasonic models.
For ultrasonic model U3-25U, a 9” PVC flange is available.
Do not attempt to measure through thefilling curtain. Make sure that the materialor product does not encroach into thedead zone.
X X
X X
Fill
FillHole
FillHole
Dead Zone
Dead Zone
Avoid interference from the side ofthe tank or from obstructions insidethe vessel. Do not install the sensorat an angle.
The sensor must be installed on the top of the vessel and must be positioned to ensure that the sensor face hasan unobstructed line of sight to the “empty” level of the tank. (Ultrasonic Sensors will not operate in a vacuum.)
To calculate the minimum distance from the wall for sensor placement, use: Minimum Distance From Wall = Tangent (Beam Angle/2) (Tank Height)
Range
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-20 © Copyright Madison Company – 10/05
Mounting of Non-Contact Level Sensors
2/3
1/3
In tanks with dome tops, thesensor should not be installedin the center. Place it 2/3 ofthe way between the wall andthe center line.
In tanks with domed tops, aimthe sensor to point toward thedischarge hole.
RF
SphericalTanks
CylindricalTanks
Conical Tanksand Hoppers
Moving Parts(During Calibration)
TypicalApplicationsfor Ultrasonicand RadarSensors
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-21
Non-Contact Level Sensors
RF
Software
Standard Mounting
Mounting the sensor correctly is critical to its proper operation. Refer to instruction manual forwiring information.
Ultrasonic – The ultrasonic sensor can bemounted directly by threading it into a 2” NPTplastic or metal mounting flange with the sensorface below the flange and pointing down, withoutmaking contact with any surface.
Radar – The radar sensor can be mounted directlyby threading it into a 2” NPT metal mounting flangewith the antenna pointing down. The radar sensormust be installed in a metal flange. If a still-pipe isrequired, it must be metal as well.
Metal Still-Pipe Mounting
Pipe Diameter(Radar models*)
2.0”3.0”
4.0” and 5.0”6.0”
Maximum Length
2.5”3.5”6.0”10.5”
StandardMounting
(Radar shown)
Mountingwith MetalStill-Pipe(Ultrasonic
shown)
2” NPT
Still-Pipe
For any Madison ultrasonic orradar model ordered with oneof the optional communicationports, the interfacing software is provided. The softwareoperates on a basic PC that is
running Microsoft Windows 95™
or higher and has a serial port.Please refer to the standardcatalog chart pages or selectthis option when completing the Madison Specification Work Sheet.
Both ultrasonic and radar sensors can beinstalled utilizing a metal still-pipe. Plastic may also be used for ultrasonic.
* For metal still-pipes that have a small ID and that are longer than 4” in this table, use 6” or 8” antenna extensions that are equal toor longer than the still-pipe.
If your mounting material or configuration doesnot comply with these notes, please consultMadison Company for proper interface.
45°
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-22 © Copyright Madison Company – 10/05
Installation of Ultrasonic or Radar Sensors
For pipes longerthan 6”, use a 45˚termination.
RF
A pulse is emitted from the sensor’s transmitter. The pulse travels tothe surface being monitored and is reflected off the surface, back tothe sensor. The time of flight is divided by 2 and converted to anoutput signal directly proportional to the material level. In the case ofthe ultrasonic sensor, temperature is measured to compensate forthe speed variation of the ultrasonic pulse.
Span(Ultrasonic)Span
(Radar)
Material
Pulse
RadarSensor
UltrasonicSensor
Dead Zone (Ultrasonic)Dead Zone(Radar)
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-23
Operation of Non-Contact Level Sensors
4 mA or 20 mA at target
RF
Full Tank Calibration
Empty Tank Calibration
20 mA or 4 mA (750 ohm max.) outputset near target (full tank)
1. Calibration mode LED color green2. Push button
Hold until LED turns yellow (20 mA)or hold until LED turns red (4 mA)
3. Release button, observe, LED flashesto acknowledge
Note: When calibrating radar sensor, lowdielectric materials mode must be OFF.See reference page for instructions.
4 mA or 20 mAset far from target (empty tank)
1. Calibration mode LED color green2. Push button
Hold until LED turns red (4 mA)or hold until LED turns yellow (20 mA)
3. Release button, observe, LED flashesto acknowledge
Note: When calibrating radar sensor, lowdielectric materials mode must be OFFSee reference page for instructions.
Calibration Push ButtonLED Indicator
FULL
Calibration Push ButtonLED Indicator
EMPTY
A single push button is used to set the zero and span. Calibration can be done in the vessel by varying thematerial level, the sensor can be calibrated on the bench by aiming it at a target or it can be set by usingprogramming. Factory-calibrated sensors can be provided; consult factory. The zero and span points areindependent of each other, fully adjustable over the sensor’s range and stored in a non-volatile memory.Calibration feedback uses LED lights in green, yellow and red. For radar and long-range ultrasonicapplications, please use the programmable calibration that is demonstrated in the instruction manual.
Note: Factory-supplied installation manuals are packaged with each sensor.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-24 © Copyright Madison Company – 10/05
Calibration of Non-Contact Level Sensors
RF
Frequently-Asked Questions
1. How can ultrasonic sensors help my customer?
They can provide a cost-effective, non-contact level measurement method with unique advantages notoffered by other sensing technologies. With the Madison line of Standard models, a full range of distanceoptions are offered. To address specific application conditions, engineered designs can be developed inconjunction with the customer.
2. What are the advantages of ultrasonic sensors?
When compared to other more conventional level measurement sensors, theMadison ultrasonic sensors…
– are not affected by dust, dirt or wet environments– have varying distance ranges that can detect many types of materials– are impervious to most materials, colors and surfaces– have a virtually unlimited, maintenance-free life– are resistant to external vibration, ambient noise and infrared or EMI radiation– adapt power and sensitivity automatically to any environmental conditions
3. How are specific application problems solved?
Madison Company has a staff of trained sales personnel and engineers that can assist the customer inselecting the appropriate standard model or recommend an engineered model based on the applicationconsiderations provided by the customer. Customers should use the Specification Work Sheet to help giveour staff a complete understanding of their needs.
4. How do the ultrasonic and radar sensors work with the software?
Madison’s standard ultrasonic and radar sensor models can be selected with a communication option. This option is a choice of an RS-232 or an RS-485 connection. The RS-232 is for a one sensor to one PC link, and the RS-485 is for up to multiple sensors (up to 128) to one PC. Madison supplies user-friendly software for sensors purchased with this option. Once the software is loaded onto the user’s PC,the user can tailor several characteristics of the sensor so that the graphs and displays of the sensor'ssignals can be representative of the measurements being taken in the vessel.
5. How do I mount the sensor to assure proper performance?
Although there are several different options that can be offered, the most common is where the sensor isscrewed into a standard fitting that is attached to the outside of the vessel. The sensor’s face or lens isinside and just below the vessel’s inside surface. The sensor should be relatively upright, aiming at thelowest part of the vessel and away from any filling source, piping, ladders, propellers, etc. that could bewithin the beam spread and cause a false echo. See diagrams on previous reference pages.
6. What about dust and foam on the material surface?
Whether or not the ultrasonic echo will be interfered with depends on how dense and how reflective thedust or foam is. Once we understand what the material is and the depth of the dust/foam above the targetmaterial, the sensor selection can be made so that the signal strength can be greater, to penetrate theinterference and provide reliable level measurement. If the application cannot be solved with the ultrasonicsensor, the radar sensor will most likely do the job.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 10/05 RF-25
Non-Contact Level Sensors
RF
Frequently-Asked Questions
7. If I have a small vessel, and the blanking distance is too great, can it be reduced?
Yes; complete the Specification Work Sheet and return it to Madison Company’s sales account manager
for a technical evaluation and quote. Each application and mounting area/method is different, so the fit up
envelope will be an important set of dimensions to make reference to (outline drawings are best). Madison
has several non-standard, alternative designs already in use that may be suitable.
8. Can the transducer housing on the end of the ultrasonic sensor be used in food applications or
applications that are not suitable for the standard PVC housing?
Yes, the transducer housing is offered in a sanitary design on several standard models; refer to the
catalog listing for the standard models. The transducer housing can also be designed in Teflon®, Kynar
and other materials.
9. What are the thread options on the sensors?
The catalog chart lists the thread for each Madison standard sensor model. The standard thread
configuration is 1” NPT. Madison can also quote the price of sensors with BSP threads, for customers
who require them.
10. What are the sensor housings made of?
The Madison ultrasonic sensors’ housings are PVC in dark gray. The PVC can be quoted in white
and light gray as well. For ultrasonic models carrying CE approval, the housing is aluminum. The Madison
radar sensors’ housings are aluminum, and it can also be quoted in 316L Stainless Steel. The radar
antenna is white polypropylene and can be quoted in Teflon®.
11. Is the Madison radar antenna only available in the cone shape?
No, although the cone shape is preferred in applications that require sanitary surfaces or have media that
tend to build up.
12. My gateway PC software doesn’t communicate with my radar or ultrasonic sensor, or the
communication has long delays?
The default serial port settings for the transmit and receive buffers are likely set too high in Windows. To
correct this, go to the Control Panel; select System; select Hardware; select Device Manager; select Ports
(COM and LPT); select Communications Port (the COM port the sensor is connected to); select Port
Settings; select Advanced; move the arrows on both Receive and Transmit Buffers to their lowest settings.
Then click OK. This should correct the problem.
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-26 © Copyright Madison Company – 03/11
Non-Contact Level Sensors
RF
C - CE
A - Underwriter’s Laboratories
Underwriter’s Laboratories is one of the world’s premier safety testing andcertification sources. Many applications require UL approval for insuranceand/or other compliance purposes. There are several areas of interest,
but the most applicable is UL 508, the Standard for Industrial Control Equipment. For moreinformation on UL, check their Web site at www.ul.com.
Madison Company offers many sensors with UL approval. Those product approvals are to aspecific design. Some modifications to an approved design may cause the approval to beinvalid. Should that be a critical issue for you, contact us to determine what course of actionwould be best.
B - Canadian Standards Association
Canadian Standards Association (CSA) tests products for compliance to nationaland international standards and issues certification marks for qualified products.Certification marks tell potential users that a product has been evaluated by aformal process involving examination, testing and follow-up inspection, and that it
complies with applicable standards for safety and performance. CSA is recognizedthroughout Canada as the premier certification organization for electrical products. Formore information on CSA, visit their Web site at www.csa-international.org.
As with UL approval, CSA certification is design-specific. Therefore, modifications to acertified design may cause the certification to be invalid. Please confer with MadisonCompany if this certification is crucial for your application.
The 15 member nations of the European Union (EU) have created a set ofproduct-specific regulations with which those companies doing business in thosenations must comply. The EU’s “New Approach Directives” constitute its unified set
of health and safety regulations, symbolized by the CE mark. The mark is required for abroad range of products, including machinery, medical devices and electrical/electronicproducts. Madison Company self-certifies all of its level switches to CE specificationsEN60730-1 and EN60730-2, and Low Voltage Directive (72/73/EEC).
Continued on next page
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 7/06 RF-27
Approval Reference
RF
E - Explosion-ProofNOTE: Individual Madison product explosion-proof approvals vary. Consult Madison Company forcurrent product listings.
Certain Madison product models have been tested and approved byUnderwriters Laboratories, Inc. for use in hazardous locations. The liquid levelswitch product is normally approved as a recognized component to be used
with a UL Listed component in hazardous locations for Class I, Groups A, B, C and D; Class II,Groups E, F and G; and Class III. Visit www.ul.com for more information.
Certain Madison product models have been tested and approved by CSA Internationalfor use in hazardous locations. The liquid level switch product is normally approved asa Class 2258 02 Process Control Equipment for hazardous locations classified as Class
A, B, C and D; Class II, Groups E, F and G; Class III. For more information on CSA, visit theirWeb site at www.csa-international.org.
ATEX Directive 94/9/EC (also known as ATEX 95 or ATEX 100A) is used in theEuropean Union (EU) to test and certify products designed for use in potentiallyexplosive atmospheres. Madison’s liquid level switch products would normally fallunder Equipment Group II, Equipment Category 2, for atmosphere group G, zones 0,
1 and 2. For more information on DEMKO, visit their Web site at www.demko.dk.
Continued on next page
D - NSF InternationalNSF International sets standards for products and systems related to public health,safety and the environment with focus on the essential elements of water, foodenvironment and air. The NSF Certification programs are accepted and frequently
mandated by public health regulators throughout the United States, as well as internationally.Madison Company offers over 30 NSF-approved sensors which meet NSF Standard C-169 – FoodEquipment and Related Products, Components and Materials. For more information on NSF, visittheir Web site at www.nsf.org.
F - International Protection Codes (IP)An IP number is used to specify the environmental protection of enclosures aroundelectronic equipment.
First Number0 – No protection (sometimes X)
1 – Protected against solid objects up to 50mm2
2 – Protected against solid objects up to 12mm2
3 – Protected against solid objects up to 2.5mm2
4 – Protected against solid objects up to 1mm2
5 – Protected against dust, limited ingress (no harmful deposit)
6 – Totally protected against dust
Second Number0 – No protection (sometimes X)1 – Protected against vertically falling drops of water (i.e. condensation)2 – Protected against direct sprays of water up to 15˚ from vertical3 – Protected against direct sprays of water up to 60˚ from vertical4 – Protected against water sprayed from all directions - limited ingress permitted5 – Protected against low-pressure jets of water from all directions – limited
ingress permitted6 – Protected against low-pressure jets of water, limited ingress permitted (i.e. ship deck)7 – Protected against the effect of immersion between 15cm and 1m 8 – Protected against long periods of immersion under pressure
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-28 © Copyright Madison Company – 8/07
Approval Reference
RF
G - NEMA
NEMA 1 Indoor Use Protects against accidental contact by personneland falling dirt
NEMA 2 Indoor Use Protects against falling dirt, liquid and light splash
NEMA 3 Outdoor Use Protects against rain, sleet, snow, dirt and dust
NEMA 3A Outdoor Use Protects against rain, sleet, snow, dirt and ice buildup
NEMA 4 In- or Outdoor Protects against dirt, dust, hosedown andheavy splash
NEMA 4X In- or Outdoor Protects against dirt, dust, hosedown and prolonged submersion
NEMA 6 In- or Outdoor Protects against dirt, dust, hosedown andoccasional submersion
NEMA 6P In- or Outdoor Protects against dirt, dust, hosedown and prolonged submersion
NEMA 7 Indoor Use For use in areas of explosive gases or vaporsor combustible dust
NEMA 9 Indoor Use For use in areas of atmospheres containingcombustible dust
NEMA 12 Indoor Use Protects against dirt, dust, light splash and oilor coolant seepage
NEMA 13 Indoor Use Protects against dirt, dust, light splash and oil orcoolant spray
National Electrical Manufacturers Association (NEMA) Standards Publication No. 250guidelines are as follows:
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/06 RF-29
Approval Reference
RF
H - entelaentela is an OSHA (Occupational Safety and Health Administration) approved testing laboratory.It is accredited by the SCC (Standard Council of Canada), for electrical product safety;participating National Certification Board (NCB) within the IECEE (the IEC System for ConformityTesting and Certification of Electrical Equipment).
Products have been tested and certified to:CSA C22.2 No. 1010.1-M92 and A2IEC 61010-1:90 and A1:92 and A2:95UL 61010A-1 (2002)
I - ABSABS (American Bureau of Shipbuilding) Type Approval certifies that the approved equipment hasbeen designed and manufactured per ABS Rules for use on shipboard applications. Any limitationof use will be listed as part of the applicable approval.
Sensors have been tested and found to comply with the limits for Class A digital device, pursuantto Part 15 of the FCC rules. These limits are designed to provide reasonable protection againstharmful interference when the equipment is operating in a commercial environment.
J - FCC
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-30 © Copyright Madison Company – 7/09
Approval Reference
K - FM GlobalFM Approvals are intended to verify that the product will meet stated conditionsof performance, safety and quality. The purpose of FM Approval Standards is topresent the criteria for FM Approval of various types of products as guidance forFactory Mutual personnel, manufacturers, users and authorities havingjurisdiction. Madison Company products having this approval reference would
require the purchaser to contact Madison Company for the specific class of product approval.
Madison Company products are in compliance with European RoHS (Restriction of HazardousSubstances) and WEEE (Waste Electrical and Electronic Equipment) directives. Our products areadditionally ESA (Electrical Safety Authority) registered in Canada.
RF
RoHS, WEEE (Europe); ESA (Canada)
Thermocouple Wire Color CodesColor codes have been adopted by various national and international standard agencies for identification ofthermocouple wire and thermocouple products. In the United States, thermocouple-grade wire normally has a brownoverall jacket. For Types B, R and S, the color codes relate to the compensating cable normally used.
Type
E
J
K
N
B
R
S
T
United StatesANSI96.1
Purple+ Purple– Red
Black + White– Red
Yellow + Yellow– Red
Orange+ Orange– Red
Grey+ Grey– Red
Green+ Black– Red
Green+ Black– Red
Blue+ Blue– Red
United KingdomBS
1843
Brown+ Brown– Blue
Black + Yellow– Blue
Red + Brown– Blue
—
—
Green+ White– Blue
Green+ White– Blue
Blue+ White– Blue
West GermanyDIN
43714
Black+ Red– Black
Blue + Red– Blue
Green + Red– Green
—
Grey+ Red– Grey
—
White+ Red– White
Brown+ Red– Brown
JapanJIS
C1610-1981
Purple+ Red– White
Yellow + Red– White
Blue + Red– White
—
Grey+ Red– White
Black+ Red– White
Black+ Red– White
Brown+ Red– White
FranceNF
C42-323
—
Black + Yellow– Black
Yellow + Yellow– Purple
—
—
—
Green+ Yellow– Green
Blue+ Yellow– Blue
National Standards
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-31
RF
Comparison of Temperature Transducers
Thermocouple Reference
Time Constants
The time constant of any sensor isdefined as the time required for thatsensor to respond to 63.2% of itstotal output signal when subjectedto a step change. The step changecan be either an increase ordecrease in the parameter beingmeasured. Five constants arerequired for a sensor to reach 99%of its total change. The graph to theright illustrates this relationship.
Type
Advantages
Disadvantages
Thermocouple
Self-powered
Simple, rugged
Lower cost
Wide temperature range
Nonlinear
Low voltage
Least stable
Least sensitive
Reference required
RTD
Most stable
Most accurate
Better linearity
Expensive
Current source required
Small resistance change
Low absolute resistance
Self-heating
Thermistor
High output
Fast
Nonlinear
Limited temp. range
Fragile
Current source required
Self-heating
0 1 2 3 4 5
63
100
Per
cen
t o
f C
han
ge
Time Constant
99%
Type
Material
Temperature Range
J
Iron (+)vs.
Constantan (-)
0˚C to 760˚C
K
Nickel (10%) Chromium (+)vs.
Nickel (5%) AluminumSilicon (-)
0˚C to 1370˚C
T
Copper (+)vs.
Constantan (-)
-160˚C to 400˚C
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
RF-32 © Copyright Madison Company – 2/05
RF
Time Constant of Exposed Thermocouples
Time Constant as a Function ofWire Size for Exposed Wire
Thermocouples in Air T=200˚F
Radiation Error of Exposed Thermocouples
Radiation Error as a Function ofWire Sizes for Thermocouples in
Air at 2000˚F, at 1 Atmosphereand Mach 0.3
0
0
0.5
1.0
1.5
2.0
.004 .008 .012 .016 .020 .024
4
Tim
e C
on
stan
t, se
c.
Wire Diameter, in. Wire Diameter, in.
T
MICRO-MINIATURE THERMOCOUPLE
40 GAUGE
36 GAUGE
30 GAUGE
28 GAUGE
26 GAUGE
24 GAUGE
22 GAUGE
400
300
200
100
00 .02 .04 .06 .08 .10 .12
T
Rad
iati
on
Err
or,
˚F
Wire Diameter, in.
T
40 GAUGE
36 GAUGE32 GAUGE30 GAUGE
26 GAUGE
24 GAUGE
20 GAUGE
16 GAUGE
10 GAUGE
8 GAUGE
MICRO-MINIATURE THERMOCOUPLE
Time Constants and Radiation Error
Madison Company • (203) 488-4477 • (800) 466-5383 • Fax (203) 481-5036 • [email protected] • www.madisonco.com
© Copyright Madison Company – 2/05 RF-33
RF
RF