Magnetic Background Issues above 1Hz for CLIC beams Cezary Jach CLIC2009

Upload: talon

Post on 22-Feb-2016

32 views

Category:

Documents


0 download

DESCRIPTION

Magnetic Background Issues above 1Hz for CLIC beams. Cezary Jach CLIC2009. 326 klystrons 33 MW, 139 m s. combiner rings Circumferences delay loop 72.4 m CR1 144.8 m CR2 434.3 m. drive beam accelerator 2.38 GeV, 1.0 GHz . CR1. CR1. 1 km. delay loop. CR2. 326 klystrons - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Magnetic Background Issues above 1Hz for CLIC beams

Magnetic Background Issues above 1Hz for CLIC beams

Cezary JachCLIC2009

Page 2: Magnetic Background Issues above 1Hz for CLIC beams

e+ injector, 2.4 GeV

e- injector2.4 GeV

CLIC 3 TeV

e+ main linace- main linac , 12 GHz, 100 MV/m, 20.85 km

BC2BC2

BC1

e+ DR365m

e- DR365m

booster linac, 9 GeV, 2 GHz or 4 GHz ?

decelerator, 24 sectors of 868 m

IP1

BDS2.75 km

BDS2.75 km

47.9 km

drive beam accelerator2.38 GeV, 1.0 GHz

combiner rings Circumferences delay loop 72.4 m

CR1 144.8 mCR2 434.3 m

CR1CR2

delayloop

326 klystrons33 MW, 139 ms

1 km

CR2delayloop

drive beam accelerator2.38 GeV, 1.0 GHz

326 klystrons33 MW, 139 ms

1 km

CR1

TAR=120m

TAR=120m

245m 245m

Page 3: Magnetic Background Issues above 1Hz for CLIC beams

Tolerance to variable fields

• In the Main Linac• In the long transfer line of the Main Beam• Near the IP• In all cases, we must consider– Frequencies above 1 Hz – Quasi-static field (above tolerance, implies re-

adjustment of the line)

Page 4: Magnetic Background Issues above 1Hz for CLIC beams

Main Linac & MB_LTL• Main Linac :

B < 0.2 nT at f>1 Hz

• Long Transfer Line :• Adding fields of variable f to the FODO

line• Track, get the beam displacement • From this, compute the tolerance ,

corresponding to 10% emittance growth after filamentation

B ≈ 0.01 nT at f>1 Hz

(To allow neat feed-back at 50 Hz - D. Schulte)

Study by J. Snuverink

(For incoherent addition by sector)

Page 5: Magnetic Background Issues above 1Hz for CLIC beams

Near the IP

Momentum Tolerance Field Current

P Δ B I @ 1m

250 GeV/c 0.1 nm 30 nT 0.14 A

1500 GeV/c 0.2 nm 80 nT 0.4 A

Current to produce B, in a conductor parallel to the beam in the horizontal planeat r from the beam axis :

s

L = 3.5 m

y

x

B

Δ⊗

Page 6: Magnetic Background Issues above 1Hz for CLIC beams

Possible Sources of Stray Magnetic Field

• High voltage transmission lines• Site power distribution system• Linac power distribution system• Electronics, vacuum pumps, compressors, etc.• Railroads• ?

Page 7: Magnetic Background Issues above 1Hz for CLIC beams

High voltage transmission lines

• Along the Jura, both in F +CH• Still awaiting detailed data from EDF and EOS• Considering a generic case:

● ●

● ●

● ●+I

+I

+I -I

-I

-I

7m

Bx = 16 nT at(+300m,-100m)

Even with the 1st-order cancellationoffered by the 3 phases , it remains :

Page 8: Magnetic Background Issues above 1Hz for CLIC beams
Page 9: Magnetic Background Issues above 1Hz for CLIC beams

Coupling rejection

Page 10: Magnetic Background Issues above 1Hz for CLIC beams

Train Leakage Currents (LEP)*

*"The Influence of Train Leakage Currents on LEP Dipole Field" - CERN SL 97-47

Page 11: Magnetic Background Issues above 1Hz for CLIC beams

Train Leakage Currents (2)

Page 12: Magnetic Background Issues above 1Hz for CLIC beams

Train Leakage Currents (3)

Page 13: Magnetic Background Issues above 1Hz for CLIC beams

Train Leakage Currents (4)

Proportional to train leakage current

Proportional to LEP vacuum chamber current

ΔB/B ≈ 10-5

Page 14: Magnetic Background Issues above 1Hz for CLIC beams

FNAL data I - Courtesy of Dmitri Sergatskov

Data taken in the A0 exp-hall

In a ‘quiet’ officebuilding :10 × lower

Page 15: Magnetic Background Issues above 1Hz for CLIC beams

FNAL data II - Courtesy of Dmitri Sergatskov

• Level 10 × above HV-network estimate∼

Page 16: Magnetic Background Issues above 1Hz for CLIC beams

Next Steps

• Confirmation of stray magnetic field sensitivities

• Stray magnetic field mapping• Proposals for stray magnetic field reduction