    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page i, Total 38

    Product Name Confidentiality

    OMStar INTERNAL

    Product Version

    38 PagesOMStar V500R006

    Maintenance Guide to OMStar V500R006

    (For internal use only)

    Prepared by: Jia Xiaorun Date: 2011-07-24

    Reviewed by: Date:

    Approved by: Date:

    Huawei Technologies Co., Ltd.

    All Rights Reserved

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    2/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page ii, Total 38

    Contents

    Huawei Technologies Co., Ltd. .................................................................................................. i

    1 Problems Related to the SQL Server ..................................................................................... 5

    1.1 Problems Related to the SQL Server Installation ........................................................................................ 5

    1.1.1 Version Mapping Between the Operating System and the Database ....................... .................. ........... 5

    1.1.2 Can the MSDE 2000 Be Used? ......................................................................................................... 5

    1.1.3 Can the OMStar Share the Database with the CME? ...................... .................. ....................... ........... 5

    1.1.4 How Do I Install SQL Server 2000 on a Server That Is Installed with SQL Server 2005? .............. ..... 6

    1.1.5 What Are the Precautions for Installing the SQL Server in the Windows 7 Operating System? ........... 8

    1.1.6 What Do I Do When the System Displays the Message "A previous program installation created

    pending file operations on the installation machine"? .................... ..................... ....................... ................10

    1.1.7 What Do I Do When the System Displays the Message "The installation program fails to configure the

    server"? ....................................................................................................................................................10

    1.1.8 What Do I Do When the System Displays the Message "command line option syntax error"?............ 11

    1.1.9 What Do I Do If the GUI is Suspended During Installation? ............................... .................... .......... 11

    1.1.10 Confirming the Patch Version and Checking Whether the Collation Setting Is Correct .................... . 11

    1.2 Problems Related to the SQL Server Connection ............... ..................... ....................... ..................... .......13

    1.2.1 SQL Server Service Not Started .......................................................................................................13

    1.2.2 Incorrect Database Instance Being Selected When the OMStar Is Logged In To ...................... ..........14

    1.2.3 Incorrect Server Name for Logging In to the Database ...................... ..................... ..................... ......14

    1.2.4 Incorrect User Name or Password for Logging In to the Database ...................... .................. .............15

    1.2.5 Invalid Connection or Common Network Error ................................................................................16

    1.2.6 SQL Server Start Failure After the Domain Password Is Changed .................... ................. ................17

    2 Problems Related to the NIC ................................................................................................ 19

    2.1 How Do I Handle the NIC Install Failure? ...................... ..................... ..................... ....................... ..........19

    2.2 How Do I Handle the NIC Startup Failure? ...............................................................................................19

    2.3 How Do I Handle the Failure of Adding NEs to the NIC? ....................... ................. ........................ ..........19

    2.4 Why Does the System Display the Message "Adaptation layer does not match the C version of the NE"

    When the User Adds an NE?...........................................................................................................................20

    2.5 Data Collection Failure Scenarios (Configuration Data, Traffic Statistics Data, and MML Data) ............... .20

    2.6 Why Does It Take Time for the NIC to Collect Inspection Data?............................ ................. ...................20

    2.7 How Do I Add NEs More Efficiently by Using the Batch Import Function? .................... ................. ..........21

    2.8 Why Does the System Display the Message "Please check whether the NIC application services and the

    database services run normally." During Batch Management of NEs? .................... ................. .........................23

    2.9 What Is the Maximum Number of NEs Whose Data Is Collected Concurrently on the NIC? ............... .......23

    2.10 What Do I Do If the Data Collection Fails? .............................................................................................24

    2.11 What Do I Do If the Internet Explorer Does Not Respond? ...................... ..................... ..................... ......24

    3 Problems Related to the Transdata ...................................................................................... 25

    3.1 System Prompting Incorrect Program Configuration at Startup of the Transdata ................... ..................... .25

    3.2 System Prompting Project Information Loading Failure and Invalid Parameters at Startup of the Transdata 25

    3.3 Exceptions That May Occur During the Data Import of the Transdata ....................... ................. ................25

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    3/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page iii, Total 38

    3.4 Alarm Data Failing to Be Imported ...........................................................................................................26

    3.5 Transdata task dose not respond in Windows 7 ................................. ........... Error! Bookmark not defined.

    3.6 Supported Format of Imported NodeB Traffic Statistics .................... ..................... ....................... .............27

    4 Problems Related to Mini_OMStar ..................................................................................... 28

    4.1 How Do I Handle the Failure to Start the Mini-OMStar Because vcredist.exe Is Not Installed? ..................28

    4.2 Why Does the System Display the Information Indicating That Transdata Is Started or Fails to Be Started

    After the Mini_OMStar Starts a Task? ............................................................................................................28

    4.3 Why Does the Mini-OMStar Fail to Create a Project? .................... ..................... ....................... ................29

    4.4 How Do I Handle the Problem That the Task Is in the Stopping State for a Long Time After the

    Mini-OMStar Stops the Task? .........................................................................................................................32

    4.5 How Do I Back Up Tasks Created by the Mini-OMStar After the OMStar Program Is Uninstalled? ............32

    5 Problems Related to OMStar ................................................................................................ 33

    5.1 The Map Cannot Be Displayed Correctly ..................................................................................................33

    5.2 Failure to Load Report Node .....................................................................................................................33

    5.3 What Do I Do If a Task Fails to Be Executed Because the Word Program Is Abnormal? ................... ..........34

    5.4 Task Manager Popping Up Occasionally When the Tool Is Generating Reports .................... ..................... .34

    5.5 Why Am I Not Allowed To Use the Copy/Paste Function of Windows During the Process of OMStar Word

    Report Generation? ........................................................................................................................................34

    5.6 Is the OMStar Compatible with Office 2007? ............................................................................................35

    6 Miscellaneous ......................................................................................................................... 36

    6.1 What Are the Precautions for Installing the OMStar in the Windows 7 Operating System? ..................... ....36

    6.2 OMstar running stop caused by automatic sleep in Windows 7 ................................. ....................... ..........37

    6.3 Problems of Using OMStar V500R006 on Windows 2003 Server .................................. ........................ ....38

    6.4 Obtaining OMStar Logs in One-Key Mode ...............................................................................................38

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    4/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 4, Total 38

    Operation Guide to the OMStar V500R006 for Maintenance

    Key Word

    SQL server, NIC, Transdata, Mini_OMStar, OMStar

    Abstract

    This document describes the FAQs that occur during the installation and using of OMStar

    V500R006 and the NE information collector (NIC). In addition, this document provides the

    solutions on the FAQs. In case of any question during the installation and the using of thetools, see the maintenance manual. If the question cannot be handled by using themaintenance manual, contact tool maintenance personnel Jia Xiaorun (ID: 00151470) forassistance.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    5/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 5, Total 38

    1 Problems Related to the SQL Server1.1 Problems Related to the SQL Server Installation

    1.1.1 Version Mapping Between the Operating System and theDatabase

    OS Version Database Version Remarks

    Windows Server 2003Standard Edition

    SQL Server 2000, StandardEdition (SP4)

    The installation and upgradecan be performed.

    Windows Server 2003

    Enterprise Edition

    SQL Server Enterprise

    Edition (SP4)

    The installation and upgrade

    can be performed.

    Windows XP SQL Server 2000personalized edition (SP4)

    The installation and upgradecan be performed.

    Windows 7 SQL Server 2000personalized edition (SP4)

    The installation and upgradecan be performed.

    The preceding configuration is the recommended standard configuration.

    1.1.2 Can the MSDE 2000 Be Used?

    1. The MSDE 2000 is equivalent to a lite edition of SQL Server 2000 with the limitedspecification (the performance decreases abruptly when the size of a single table exceeds

    2 GB). The MSDE 2000 is not recommended especially when the performancemeasurement data collected from a single BSC exceeds 150 MB.

    2. If the conditions for installing the SQL Sever 2000 are not met but users can take the lowefficiency risks caused by the MSDE, the GENEX MSDE program must be installed.

    The GENEX MSDE program can be downloaded from the following URL:http://support.huawei.com/support/pages/editionctrl/catalog/ShowVersionDetail.do?actionFlag=getDetail&node=000001423430&colID=ROOTENWEB|CO0000000174.

    3. The MSDEs of other vendors may not be applicable to normal analysis of the OMStar.

    1.1.3 Can the OMStar Share the Database with the CME?

    The database for the OMStar is incompatible with that for the CME.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    6/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 6, Total 38

    Cause:

    The CME uses SQL Server 2005 Express. SQL Server 2005 Express does not support theimport of multiple threads. Therefore, the OMStar cannot use it.

    Solution:

    The OMStar supports that SQL Server2000 and SQL Server 2005 are installed on the sameserver. For details about the installation method and precautions, see section 1.1.4 "How Do IInstall SQL Server 2000 on a Server That Is Installed with SQL Server 2005?"

    Except SQL Server 2000, the OMStar can support the SQL Server 2005 Standard and SQLServer 2005 Express, which is only compatible with the Windows Server 2003 and laterversions.

    1.1.4 How Do I Install SQL Server 2000 on a Server That IsInstalled with SQL Server 2005?

    SQL Server2000 and SQL Server 2005 must use different instance names. When installingSQL Server 2000, you must specify an instance name under Instance name, as shown the

    following figure.

    If the server is installed with the SQL Server 2005 database, check whether SQL Server 2005uses the default port, 1433.

    To check the port used by SQL Server 2005, choose Start> All Programs> Microsoft SQLServer 2005> Configuration Tools> SQL Server Configuration Manager> SQL Server2005 Network Configuration> Protocols for MSSQLSERVER.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    7/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 7, Total 38

    Double-click TCP/IPand click the IP Addresstab in the displayed dialog box.

    SQL Server 2000 must use a port different from that used by SQL Server 2005. For example,

    set Port numberto 1434for SQL Server 2000.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    8/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 8, Total 38

    After SQL Server 2000 is installed, the SQL Server 2005 instance maps the MSSQL.1folderand the SQL Server 2000 instance maps the MSSQL$mssfolder in the SQL Server

    installation directory. Set the SQL Server instance name in the Login Serverdialog box, asshown in the following figure.

    1.1.5 What Are the Precautions for Installing the SQL Server inthe Windows 7 Operating System?

    The SQL Server 2000 that is compatible with the Windows XP operating system may not beinstalled properly in the Windows 7 operating system. Do not install the SQL Server by

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    9/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 9, Total 38

    double-clicking autorun.exe in the installation package; otherwise the following error message

    is displayed:

    To solve the problem, do as follows: Double-click setup.batin the installation package. TheProgram Compatibility Assistantdialog box is displayed twice informing that this programhas known compatibility issues. Click Run program. The follow-up operations are the same

    as those performed in the Windows XP operating system. The error message displayed duringinstallation can be ignored. Database errors are not encountered temporarily.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    10/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 10, Total 38

    1.1.6 What Do I Do When the System Displays the Message "Aprevious program installation created pending file operations onthe installation machine"?

    Cause:

    This error usually occurs when the SQL Server is uninstalled and then reinstalled.

    Solution:

    Delete the key value "PendingFileRenameOperation" in

    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager ofthe registry.

    1.1.7 What Do I Do When the System Displays the Message "Theinstallation program fails to configure the server"?

    Cause 1:

    The previously installed SQL Server 2000 is uninstalled incompletely.

    Solution:

    Delete the Microsoft SQL Serverfolder in C:\Program Files.

    Find "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SQL Server"in the registry and delete it.

    Cause 2:

    The name of the PC running Windows contains lower-case letters.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    11/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 11, Total 38

    Solution:

    The SQL Server 2000 fails to be installed when the name of the PC running Windowscontains some or only lower-case letters, with the message of general network error in thesqlstp.logfile.

    To solve this problem, change the lower-case letters to upper-case letters. For example, to

    change the PC name fromjys0800964to JYS0800964, do as follows:

    Open the registry (by running the regeditcommand in the Runwindow), find

    "HKEY_LOCAL_MACHINE\System\CurrenControlSet\Control\ComputerName\ComputerN

    ame" and"HKEY_LOCAL_MACHINE\System\CurrenControlSet\Control\ComputerName\ActiveCom

    puterName", and then change the primary key value of 'ComputerName' fromjys0800964toJYS0800964. Then, log out the user or restart the system to make the modification take effect.

    1.1.8 What Do I Do When the System Displays the Message"command line option syntax error"?

    Cause:

    The cause of this error is that the name of the directory for saving the source files of the SQLServer installation package contains Chinese characters. In this case, the SQL Server can be

    installed successfully after you click OK, but the OMStar fails to connect to the database.

    Solution:

    Ensure that the name of the directory for saving source files of the SQL Server does notcontain any Chinese character.

    1.1.9 What Do I Do If the GUI is Suspended During Installation?

    Cause:

    The version of the database does not match with that of the operating system.

    Solution:

    The SQL Server 2000 Personal Edition should be installed for Windows XP. Check whether

    the SQL Server Standard Edition or Enterprise Edition is installed on Windows XP (the twoeditions can be installed only on Windows Server 2000 or Windows Server 2003).

    1.1.10 Confirming the Patch Version and Checking Whether theCollation Setting Is Correct

    To check the patch version and collation setting, perform the following steps:

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    12/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 12, Total 38

    Step 1 Choose Start> Program> Microsoft SQL Server> Enterprise Manager.

    The Console Rootwindow is displayed, as shown in Figure 1-1.

    Figure 1-1Console Root window

    In the Console Rootwindow, choose Tree> SQL Server Group> xxxx (Windows NT).Right-click xxxx (Windows NT), and choose Properties.

    The SQL Server Propertieswindow is displayed, as shown in Figure 1-2.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    13/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 13, Total 38

    Figure 1-2SQL Server Properties window

    In the SQL Server Propertiesdialog box, check whether the Product versionand Server

    collationfields are correct..

    ----End

    1.2 Problems Related to the SQL Server Connection

    1.2.1 SQL Server Service Not Started

    Solution:

    Check whether the server is started in the SQL Server Service Managerwindow. If theserver is not started, start it.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    14/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 14, Total 38

    1.2.2 Incorrect Database Instance Being Selected When theOMStar Is Logged In To

    Solution:

    Multiple database instances are configured on certain devices. Check whether the name of theselected database instance is correct when logging in to the OMStar. You can view all

    installed database instances by using the SQL server service manager to ensure that theincorrect database instance is selected when you log in to the OMStar.

    1.2.3 Incorrect Server Name for Logging In to the Database

    Solution:

    Verify that the typed server name is correct. Note that the only the slash "\" can be contained

    in the server name. The following figure shows the incorrect server name:

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    15/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 15, Total 38

    1.2.4 Incorrect User Name or Password for Logging In to the

    DatabaseSolution:

    Solution 1: Verify that the user name or password for logging in to the database is correct.

    Solution 2: If you forget the user name or password, perform the following steps to modifythe user name or password:

    Step 1 Choose Microsoft SQL Server> Enterprise Manager.

    Step 2 In the SQL Server Enterprise Managerwindow, choose Microsoft SQL Servers>

    SQL Server Group> (local) (Windows NT)> Security> Loginsfrom the left

    navigation tree to view the names of users that have logged in to the database. To modify

    the password of a user, right-click a user in the right pane and choose Propertiesfrom the

    shortcut menu. To create a new user, right-click a user in the right pane and choose New

    Loginfrom the shortcut menu.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    16/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 16, Total 38

    ----End

    1.2.5 Invalid Connection or Common Network Error

    Either of the following log is recorded in the WCDMA\UNP\Log\...\ofc.logfile:

    [Microsoft][ODBC SQL Server Driver][DBNETLIB]invalid connection or[Microsoft][ODBC SQL Server Driver][DBNETLIB]common network error.

    Solution:

    Solution 1: Open the configuration manager, and then double-click TCP/IP to view theTCP/IP configuration.

    Check that the TCP dynamic port is left blank.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    17/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 17, Total 38

    Solution 2: Restart the service by using the service manager. Note that you need to perform

    this operation several times to solve this problem.

    1.2.6 SQL Server Start Failure After the Domain Password IsChanged

    Solution:Choose Control Panel> Management Tools> Services. In the displayed window,

    right-click MSSQLSERVERand choose Propertiesfrom the shortcut menu. Then, click the

    Logintab and change the password to the password of the current domain user.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    18/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 18, Total 38

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    19/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 19, Total 38

    2 Problems Related to the NIC2.1 How Do I Handle the NIC Install Failure?

    1. The NIC tool can only support installed in Chinese or English operating system, andother small language operating systems do not support.

    2. Installation user must have Administrator privileges

    2.2 How Do I Handle the NIC Startup Failure?1. At present, the ports conflict between the M2000 client and the NIC. Therefore, disable

    the M2000 client before starting the NIC.

    2. For other causes, send the log information to R&D engineers for troubleshooting.

    2.3 How Do I Handle the Failure of Adding NEs to theNIC?

    1. Check whether the user name and password are correct, that is, check whether the loginby using the LMT succeeds.

    2. Check whether the IP address in FTP Server Configuration is consistent with the IPaddress of the PC.

    If the IP addresses are inconsistent, modify them and restart the NIC to make themodification take effect. (Caution: Restart the NIC program without restarting theInternet Explorer.)

    3. Check Mediation layer managerto ensure that mediation matching the version of theNE whose data needs to be collected has been installed.

    4. For other causes, send the log information to development engineers for troubleshooting.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    20/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 20, Total 38

    2.4 Why Does the System Display the Message"Adaptation layer does not match the C version of theNE" When the User Adds an NE?

    1. This error is a type of NE adding failures. Check whether the mediation matching the NEversion is installed.

    2. If the mediation matching the NE version is installed, the possible cause is that the NIC

    of Chinese version has been manually installed with the mediation of English version.

    2.5 Data Collection Failure Scenarios (ConfigurationData, Traffic Statistics Data, and MML Data)

    1. If the NIC fails to be connected to NEs, check whether the FTP Server of the NIC isdisabled.

    Do not disable the FTP Server during startup or running of the NIC.

    2. Check whether the IP address in FTP Server Configuration is consistent with the IPaddress of the PC.

    If the IP addresses are inconsistent, modify them and restart the NIC to make themodification take effect. (Caution: Restart the NIC program without restarting theInternet Explorer.)

    3. Check whether the user has the operation right.

    It is recommended to collect data as user admin; otherwise, the collection may fail dueto lack of rights for certain collection items.

    Check whether the user is authorized to operate MML commands. If the user is notauthorized to operate MML commands, collecting configuration data and MML datamay fail.

    Check whether the user is authorized to back up configuration files. If the user is notauthorized to back up configuration files, collecting configuration files may fail.

    Check whether the user is authorized to run the BINcommand. If the user is notauthorized to run the BINcommand, collecting traffic statistics data may fail.

    2.6 Why Does It Take Time for the NIC to CollectInspection Data?

    1. Check whether the BSC6000 mediation of the NIC V100R006C00T downloaded fromhttp://support.huawei.com.

    2. Check whether the default SOP scenario of the NIC is used for collection (it isunnecessary to collect the massive data such as logs for inspection or SOP).

    3. At present, the NIC reports the progress according to collection items. The executionsequence of the collection items may change each time a task is created. If the amount ofthe data collected by the first collection item is large, the required time is longer anddisplayed as X%.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    21/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 21, Total 38

    4. The execution sequence of collection items may change each time a task is created.

    When the items with a small amount of data are collected in priority, it seems that thecollection becomes faster.

    5. If the collection progress does not change for a long time, send the log information toR&D engineers to check whether the NIC still collects data.

    2.7 How Do I Add NEs More Efficiently by Using theBatch Import Function?

    1. Choose NE Management> NE Information Maintenance, and click Batch Manage.

    2. In the Batch Managewindow, click Download Template to save the template to thelocal PC.

    3. Open the batch import template (XLS file) downloaded to the local PC and generate anXML file according to the description.

    The generated XML file is saved in the NE List folder in the same-level directory as theXLS template.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    22/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 22, Total 38

    4. In the Batch Manage window, click Browse, select the .xml file, and then click Import.

    5.

    After the XML file is imported, click OK.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    23/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 23, Total 38

    2.8 Why Does the System Display the Message"Please check whether the NIC application servicesand the database services run normally." DuringBatch Management of NEs?

    It is a bug of the NIC V100R005C00SPC200. This error occurs when the imported .xml file

    contains Chinese characters because the default XML code is UTF-8. You can use either ofthe following methods to solve this problem:

    Modify the NE name to contain only English characters.

    Modify the XML code to GB2312.

    If you have any question, contact R&D engineers.

    2.9 What Is the Maximum Number of NEs WhoseData Is Collected Concurrently on the NIC?

    NIC V100R006C00T and earlier versions:

    1. The maximum number of multiple collection tasks running concurrently on the NIC is10.

    2. The maximum number of NEs whose data is collected concurrently in a single collectiontask is 5.

    3. The maximum number of NEs (including BSCs/RNCs and BTSs/NodeBs) created in asingle collection task is 100.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    24/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 24, Total 38

    Versions later than the NIC V100R006C00T:

    1. The maximum number of multiple collection tasks concurrently running on the NIC is 5.

    2. The maximum number of NEs whose data is collected concurrently in a single collectiontask is 10.

    3. The maximum number of NEs (including BSCs/RNCs and BTSs/NodeBs) created in asingle collection task is 250.

    To sum up, the maximum number of NEs whose data is collected concurrently on theNIC is 50.

    Currently, the data for maintenance SOP is collected only from BSCs or RNCs.

    2.10 What Do I Do If the Data Collection Fails?If the acquisition task has been completed, but some of the network element or part of

    the data collection fails, you can use the fill mining function acquisition.In the Task Managerscreen, select the task to make mining and choose to make mining.

    This feature NIC V1R6C00SPC100T and later versions, NIC V1R6C00T and earlier do not have thisfeature.

    2.11 What Do I Do If the Internet Explorer Does NotRespond?

    Cause:

    This problem occurs because users installed other versions of NIC, and the buffer informationin the Internet Explorer is not cleared.

    Solution:

    Clear the buffer information in the Internet Explorer as follows:

    Step 1 Start the Internet Explorer.

    Step 2 On the main menu, choose Tool > Internet Options.

    Step 3 On the General tab page in the Internet Options dialog box, click Deletein the InternetTemporary File area.

    Step 4 Log in to the network information collection page once again.

    ----End

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    25/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 25, Total 38

    3Problems Related to the Transdata

    3.1 System Prompting Incorrect ProgramConfiguration at Startup of the Transdata

    Cause:

    The possible cause is that the OS of an earlier version is installed on the PC.

    Solution:

    Install the vcredist_x86.exepatch.

    vcredist_x86.exe

    3.2 System Prompting Project Information LoadingFailure and Invalid Parameters at Startup of theTransdata

    Cause:

    This error occurs when the Nastar CS Transdata or the CDMA Transdata was deployed on the

    PC but the project library was directly deleted from the PC.

    Solution:

    This prompt does not affect other project operations. You can directly click OKand then

    proceed according to the normal procedure.

    3.3 Exceptions That May Occur During the Data

    Import of the Transdata The import data format or the import data content is incorrect, as shown in Figure 3-1.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    26/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 26, Total 38

    Figure 3-1Prompt of incorrect data format or content

    The disk space is insufficient, as shown in Figure 3-2.

    Figure 3-2Prompt of insufficient disk space

    3.4 Alarm Data Failing to Be Imported

    Cause:

    The same alarm data can be imported on certain devices but fails to be imported on a certaindevice.

    This problem occurs because the ordering rules during the installation of the database areincorrect.

    Solution:

    For details about the method of checking whether ordering rules of the database are correct,see section 1.1.10 "Confirming the Patch Version and Checking Whether the Collation Setting

    Is Correct."

    If ordering rules are incorrect, make correct ordering rule of the database. Then, the problemis solved.

    3.5 Windows 7 installed with SQL Server 2000 doesnot support the large amount of data imported

    Windows 7 system installed with SQL Server 2000 ,and when imported large amount of

    data into the Transdata ,the Transdata will be no response occasionally.

    Cause:

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    27/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 27, Total 38

    Windows 7 system installed with SQL Server 2000,the course will be occasional virtual

    memory overflow(when imported large amount of data into the Transdata,about 25 BSC,andeach BSC the data about 800M),resulting in Transdata data import task not working.

    Solution:

    The problem is occasional, usually by restarting the SQL Server to circumvent.Restart the

    SQL Server services,then restart the Transdata task.

    3.6 Supported Format of Imported NodeB TrafficStatistics

    Currently, NodeB traffic statistic files only in CSV format exported from the M2000 can beimported and analyzed.

    NodeB traffic statistic files are named as follows: pmresult_counter set_granularity_starttime_end time_csv.

    For example:The following shows an example of a traffic statistic file related to HSDPA:

    pmresult_50331648_15_200709150000_200709150015.csv

    The following shows an example of a traffic statistic file related to Iub:

    pmresult_50331649_15_200709150000_200709150015.csv

    The following shows an example of a traffic statistic file related to the CE interface:

    pmresult_50331650_15_200709150000_200709150015.csv

    The following shows an example of a traffic statistic file related to HSUPA:

    pmresult_50331651_15_200709150000_200709150015.csv

    The following shows an example of a traffic statistic file related to OPERATOR:

    pmresult_50331652_15_200807012300_200807012315.csv

    The following shows an example of a traffic statistic file related to the CPC cell:

    pmresult_50331653_15_200807012300_200807012315.csv

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    28/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 28, Total 38

    4 Problems Related to Mini_OMStar4.1 How Do I Handle the Failure to Start theMini-OMStar Because vcredist.exe Is Not Installed?

    Cause:

    When you run the Mini-OMStar, the following message is displayed because the vcredist.exeis not installed.

    Solution:

    After the vcredist.exe is installed, restart the Mini-OMStar.

    The directory for saving the vcredist.exe is as follows: \OMStar V500R006_ENG \OMStarV500R006\Mini_OMStar\vcredist_x86.exe.

    4.2 Why Does the System Display the InformationIndicating That Transdata Is Started or Fails to BeStarted After the Mini_OMStar Starts a Task?

    Cause:

    Transdata is manually started or Transdata is stopped abnormally, but the Transdata processstill exists in the task manager.

    Solution:

    If Transdata is started, stop Transdata and then restart the Mini task.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    29/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 29, Total 38

    In case of other situations, check whether the Transdata process exists in the task manager. If

    the Transdata process exists in the task manager, stop the process and then restart the Minitask.

    4.3 Why Does the Mini-OMStar Fail to Create aProject?

    Cause 1:

    1. If the version is earlier than OMStarV500R006C03SPC400, by default, the automaticimport and analysis tasks created by the Mini-OMStar in one key mode are saved in

    disk D. If disk D is unavailable on the PC, the data cannot be imported automatically.

    Solution:

    Check the versions of OMStar and whether disk D is available on the PC.

    Step 2 Open the config.inifile in the installation directory\OMStar

    V500R006\Mini_OMStar\config.inidirectory.

    Step 3 Find the DBPATHfield and change Dbehind the equal mark (=) to a disk label available ona local PC. At least 2 GB free space is required in the available disk.

    ----End

    Cause 2:

    The disk space is insufficient.

    Solution:

    Check the size of the disk space. If the disk space is insufficient, configure a disk with

    sufficient space (based on experience, size of disk space = size of data package x 25). In caseof a task involving multiple NEs, the required disk space is subject to the NE that has thelargest amount of data.

    Cause 3:

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    30/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 30, Total 38

    The user does not have permission on the associated disk files.

    Solution:

    Check whether the disk for project creation has the write property. If the disk does not havethe write property, set the write property or configure a disk that has the write property.

    Cause 4:

    The SQL Server Patch Version and the Collation Setting are incorrect.

    Solution:

    Firstly confirming the Patch Version and checking whether the Collation Setting is correct,you can follow to section 1.1.10 "Confirming the Patch Version and Checking Whether theCollation Setting Is Correct." If the Patch Version or the Collation Setting is not correct,please reinstall the SQL Server.

    Cause 5:

    The database is removed and then installed. Commonly, SQL 2005 database is installedbefore the removal but SQL 2000 database is installed after the removal. Certain database

    files are not cleared when the database is removed.

    Solution:

    Step 1 Open the SQL Server Enterprise Manager.

    Choose Start> Program> Microsoft SQL Server> Enterprise Manager.

    Check whether the file that is named beginning with Nastarexists. If the file exists,

    right-click the file and choose Delete.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    31/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 31, Total 38

    Step 2 Check whether the file that is named beginning with Nastarexists in the installation directoryof the database. If the file exists, delete it.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    32/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 32, Total 38

    Step 3 Start the SQL service and restart the Mini_OMStar.

    ----End

    4.4 How Do I Handle the Problem That the Task Is inthe Stopping State for a Long Time After theMini-OMStar Stops the Task?

    The Mini-OMStar supports periodic stopping of tasks. After you stop a task that is running on

    the Mini-OMStar, the task is waiting for being stopped until it runs to a certain stage. Youneed to wait with patience.

    4.5 How Do I Back Up Tasks Created by the

    Mini-OMStar After the OMStar Program IsUninstalled?

    The automatic tasks are saved in the project folder in the root directory of the OMStarprogram. When the OMStar is uninstalled, the project folder is also deleted. Therefore, youneed to back up the project folder before uninstalling the OMStar. After the OMStar of a new

    version is installed, you need to copy the project folder to the directory of the OMStarprogram.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    33/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 33, Total 38

    5 Problems Related to OMStar5.1 The Map Cannot Be Displayed Correctly

    Cause:

    Project parameter data is not imported or GenexShare components are not installed.

    Solution:

    Check whether project parameter data is imported.

    If the project parameter data is imported, check whether GenexShare components are installed.If GenexShare components are not installed, install the components. Then the map can bedisplayed normally.

    5.2 Failure to Load Report Node

    When the report node is loaded, a dialog box shown in Figure 5-1 is displayed, indicating thatthe report is locked by IT DIVISION and cannot be edited. After users click OK, this nodestill cannot be loaded successfully.

    Figure 5-1File In Use dialog box

    Cause:

    This problem occurs because the template file is closed abnormally last time. As a result, aword process exists in the process list.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    34/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 34, Total 38

    Solution:

    After users close such word process, this problem is solved.

    5.3 What Do I Do If a Task Fails to Be ExecutedBecause the Word Program Is Abnormal?

    After you run a task, the Fail to execute task dialog box is displayed. If the problem persists

    after the OMStar V500R006 NetworkEvaluate is restarted, you can infer that the cause is thatthe Word program on the PC is abnormal.

    Solution:

    In this case, you need to run FixTool (2).batin the\OMStar V500R006\WCDMA directoryand restart the PC.

    5.4 Task Manager Popping Up Occasionally When theTool Is Generating Reports

    Solution:

    The task manager pops up occasionally when the tool is generating reports.

    Solution:

    The popped task manager, however, does not affect the functions and execution results of the

    tool. Engineers are working on this problem.

    5.5 Why Am I Not Allowed To Use the Copy/PasteFunction of Windows During the Process of OMStarWord Report Generation?

    When the OMStar is generating a DOC report, a lot of charts and pictures will be copied from

    the temporary Excel file and pasted to the DOC report, so using the copy/paste functionsomething of Windows may cause a DOC report generate failure. Therefore, you are not

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    35/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 35, Total 38

    recommended to use the copy/paste function of Windows during the generation of a DOC

    report.

    5.6 Is the OMStar Compatible with Office 2007?The OMStar V500R006C01T and later versions can support Office 2007.

    The OMStar cannot be used if both Office 2003 and Office 2007 are configured on the same

    computer.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    36/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 36, Total 38

    6 Miscellaneous6.1 What Are the Precautions for Installing theOMStar in the Windows 7 Operating System?

    The installation and usage of the OMStar that is developed based on the Windows XPoperating system may be affected because the security control in the Windows 7 operating

    system is different from that in the Windows XP operating system.

    The known issues are as follows:

    License verification is not performed for reinstalling the OMStar. This occurs because youhave set the UAC to a high level. In this case, you do not need to import the license again for

    reinstalling the OMStar. However, the validity period and authority are still controlled by thelicense that is imported previously. It is recommended that you set the UAC to the lowestlevel.

    To change UAC settings, do as follows: Choose Start> Control Panel> User Accounts. Inthe displayed User Accountspage, click Change User Account Control Settings.

    The OMStar may fail to read or write files in the installation directory, which causes thatOMStar runs abnormally. For example, the OMStar fails to read or write logs or createnecessary temporary folders.

    This occurs because you have not logged in to the Windows 7 operating system as userAdministrator and the OMStar is installed on the drive C.

    It is recommended that you log in to the operating system as user Administrator. In addition,to start the OMStar, do as follows: Right-click the OMStar icon and choose Properties from

    the shortcut menu. In the displayed SETUP Propertiesdialog box, click Compatibility,select Run this program as an administrator, and click OK.

    The OMStar fails to be uninstalled even through the message is displayed indicating that the

    software is uninstalled successfully. However, some files cannot be deleted and the OMStar

    fails to be reinstalled. This occurs because you have set the UAC to a high level. If thesecurity level is set too high, the OMStar is not authorized to delete all files. It is

    recommended that you set the UAC to the lowest level.

    To change UAC settings, do as follows: Choose Start> Control Panel> User Accounts. In

    the displayed User Accountspage, click Change User Account Control Settings.

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    37/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 37, Total 38

    6.2 OMstar running stop caused by automatic sleep inWindows 7

    The automatic sleep function is started in default; OMSTAR will be stopped by systemautomatic sleep during the running.

    To change automatic sleep setting, do as follow: Choose Start> Control Panel> Hardware

    Sound> Power Options, click Change when the computer sleeps.

    Figure 6-1Select Change when the computer sleeps in Power Option

  • 5/20/2018 Maintenance Guide to OMStar V500R006

    38/38

    Maintenance Guide to OMStar V500R006 Confidentiality:

    2012-04-12 Huawei Confidential Page 38, Total 38

    Figure 6-2Select Never in the Put the computer to sleep, then click Save changes

    6.3 Problems of Using OMStar V500R006 on Windows

    2003 ServerThe standalone OMStar V500R006 NetworkEvaluate does not support the operations ofmultiple users at the same time when it is installed on a Windows 2003 server.

    If the OMStar V500R006 NetworkEvaluate uses the database on the server, the operating

    efficiency of the NetworkEvaluate will be affected when multiple users access the database atthe same time.

    6.4 Obtaining OMStar Logs in One-Key ModeRun the GetInfo.exe tool in the installation path of the OMStar, for example, D:\Program

    Files\OMStar V500R006\OMStar V500R006\GetInfo.exe

    In the path, the log folder named All_log_filesis generated.