Make the most of your energy

Looking for accurate electricenergy metering and simple,easy installation?

PowerLogic® Energy Meter

December 2008 Energy Meter

Schneider Electric 2- Marketing – Energy Meter – December 2008

PowerLogic® Energy Meter

● Stand-alone electrical sub-meter with built in display

● High Resolution Backlit LCD display provides not only valuable energy data but also diagnostic and alarming information

● Optional communications network capability for communications to a PowerLogic system

● 1% accuracy for meter system with meter and CT’s being calibrated together.

● Easy to use and install split-core CT’s with self gripping Iris

● Enhanced model has kWh pulse output and phase loss alarm contact - easy interface to Building Automation Systems

● Monitors up to 3 separate circuits with additional CT’s

Schneider Electric 3- Marketing – Energy Meter – December 2008

Both models offer the same readings

Basic Model

● kWh, Energy Consumption

● kW (3 Ph. & Total), Power

● kW Max

● kVAR, Reactive Power

● kVA, Apparent Power

● Power factor (3 Ph & Total)

● Amps (3 Ph & Avg)

● Volts (3 Ph & Avg)

● kW Demand [with EMCB]

Extended Range Model

● kWh, Energy Consumption

● kW (3 Ph. & Total), Power

● kW Max

● kVAR, Reactive Power

● kVA, Apparent Power

● Power factor (3 Ph & Total)

● Amps (3 Ph & Avg)

● Volts (3 Ph & Avg)

● kW Demand [with EMCB]

Schneider Electric 4- Marketing – Energy Meter – December 2008

Model Comparison(Differences in Red)

Basic Model

● Hi-Res Backlit Display

● IR port

● Optional Modbus communication card with kWD (interval)

● 120/240V and 120/208V services

Extended Range Model

● Hi-Res Backlit Display

● IR port

● Optional Modbus communication card with kWD (interval)

● Extended voltage range: 120-600V

● kWhr pulse output

● Phase loss output

Schneider Electric 5- Marketing – Energy Meter – December 2008

Applications

●Commercial tenant submetering●Multi-residential buildings●Performance Contracting●Cost Allocation●Real time power monitoring via local display or through DCS or

PowerLogic systems

Schneider Electric 6- Marketing – Energy Meter – December 2008

Display

●High resolution backlit display provides energy readings, and diagnostics

●Straight forward information - no need to apply multipliers

Schneider Electric 7- Marketing – Energy Meter – December 2008

208/120 VAC, 3-wire three phase

EMB3

240 VAC, 3-wire Single phase

EMB2 120 VAC, 2-wire Single phase

EMB1

System type must be known

to order the correct Energy Meter

Application wiring examples

Schneider Electric 8- Marketing – Energy Meter – December 2008

Part Number Description

One CTEMB1-010 Energy Meter, Basic 100A, Size 0, 1 CTEMB1-021 Energy Meter, Basic 200A, Size 1, 1 CT

Two CTsEMB2-010 Energy Meter, Basic 100A, Size 0, 2 CTsEMB2-021 Energy Meter, Basic 200A, Size 1, 2 CTsEMB2-083 Energy Meter, Basic 800A, Size 3, 2 CTs

Three CTsEMB3-010 Energy Meter, Basic 100A, Size 0, ID, 3 CTsEMB3-021 Energy Meter, Basic 200A, Size 1, 3 CTsEMB3-083 Energy Meter, Basic 800A, Size 3, 3 CTsEMB3-084 Energy Meter, Basic 800A, Size 4, 3 CTs

Basic Model

Schneider Electric 9- Marketing – Energy Meter – December 2008

Part Number Description

One CTEME1-010 Energy Meter, Extended Range 100A, Size 0, 1 CTEME1-021 Energy Meter, Extended Range 200A, Size 1, 1 CT

Two CTsEME2-010 Energy Meter, Extended Range 100A, Size 0, 2 CTsEME2-021 Energy Meter, Extended Range 200A, Size 1, 2 CTsEME2-083 Energy Meter, Extended Range 800A, Size 3, 2 CTs

Three CTsEME3-010 Energy Meter, Extended Range 100A, Size 0, 3 CTsEME3-021 Energy Meter, Extended Range 200A, Size 1, 3 CTsEME3-083 Energy Meter, Extended Range 800A, Size 3, 3 CTsEME3-084 Energy Meter, Extended Range 800A, Size 4, 3 CTsEME3-164 Energy Meter, Extended Range 1600A, Size 4, 3 CTs

Extended Range Model

Schneider Electric 10- Marketing – Energy Meter – December 2008

Options

Part Number Description

EMCB Energy Meter Communication Board

EMFP1 Energy Meter Fuse Pack, Set of 1 EMFP2 Energy Meter Fuse Pack, Set of 2 EMFP3 Energy Meter Fuse Pack, Set of 3

Schneider Electric 11- Marketing – Energy Meter – December 2008

Dimensions

Schneider Electric 13- Marketing – Energy Meter – December 2008

Size 0

Size 1

CT Dimensions

Schneider Electric 14- Marketing – Energy Meter – December 2008

Size 3

Size 4

CT Dimensions

Schneider Electric 15- Marketing – Energy Meter – December 2008

Energy Meter – Easy Installation

●3 Simple Steps● Mount the meter

● Connect the COLOR CODED voltage leads (fuse kit is a must)

● Connect the COLOR CODED CT’s (auto corrects for reverse CT)

Schneider Electric 16- Marketing – Energy Meter – December 2008

Energy Meter - Installation

Schneider Electric 17- Marketing – Energy Meter – December 2008

Energy Meter - Communications

●Modbus Communications● Easily connect to Power Monitoring or BMS

●Measures Demand/Interval●2 or 4 wire compatible●Field Retrofitable

Schneider Electric 18- Marketing – Energy Meter – December 2008

More Submetering Products

●Multiple Meter Enclosures – HDM● Available in 1, 4, 8 and 16 meter sizes

●Socket Meters● Revenue accurate● On board communications and pulse output● Multiple socket form factors available

●Tenant Metering Software● Automatic meter reading and billing generation

Schneider Electric 19- Marketing – Energy Meter – December 2008

Application Example – which model to specify?

●Customer has a requirement to monitor a 480 Volt 3 phase 4 wire panel with 200 amp feeders. Application requires local readout for kWh

● First the 480V requirement is too high for the Basic model therefore the Enhanced must be selected

● Referring to the list of Enhanced models find the p/n with 3 CT’s rated at 200Amps

● Therefore the correct p/n will be EME3-021 (Enhanced / 3 CT / 200A / size1)

●If the application requires also requires that the meter provide 15 minute kW Demand info via a serial connection to a remote system then the Communications Board would also be required

● p/n would be EMCB

●Make sure to advise the customer to that Fuses are required for proper installation and specify…

● p/n EMFP3 / Energy Meter Fuse Pack, Set of 3

Schneider Electric 20- Marketing – Energy Meter – December 2008

Literature

●Doc# 3020HO0002R4/08

Schneider Electric 21- Marketing – Energy Meter – December 2008

Instruction Bulletins

Energy Meter Installation Doc# 63230-216-201A5

Addendum: Parallel CT Installation Doc# 63230-216-227A1

Communication BoardDoc# 63230-216-213A1

Schneider Electric 22- Marketing – Energy Meter – December 2008

Submetering Part #’s – Digest Section 4