manage your emc captiva 7.1 upgrade with application performance management

11

Click here to load reader

Upload: reveille-software

Post on 21-Jun-2015

2.035 views

Category:

Technology


0 download

DESCRIPTION

Learn tips and best practices about how application performance management can help you successfully complete your migration. See how performance benchmarks and key performance indicators pre- and post-upgrade can help set expectations and measure results - streamlining the upgrade process. Presentation includes: - Who needs to upgrade to EMC Captiva 7.1 - 4 steps to getting prepared and details: 1) clean up existing Captiva system, 2) recommended new hardware/operating systems, 3) establish performance baselines, 4) test/prepare for update - How you successfully QA your upgrade process See how Reveille can help with pre-configured Captiva metrics, pre- and post-upgrade values, at-a-glance trending and more. Take a product tour: reveillesoftware.com/product-tour

TRANSCRIPT

Page 1: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Manage Your EMC® Captiva® 7.1 Upgrade

Are you Ready?

Page 2: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Who’s Upgrading?

2

InputAccel 6.5 SP2

InputAccel 6.5 SP1

InputAccel 6.5

InputAccel 5.3 SP4

Captiva Capture

7.0

InputAccel 6.0 SP3

Page 3: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

First thing first,

Get Prepared

Page 4: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Clean Up Existing Captiva System

• Check for old batches, which can cause problems when updating

• Zero priority batches

• Task with error status

• Locked batches

• Old incomplete batches

• 7.1 Update process will update the Captiva Database

4

1 Reminder:

Reveille’s out-

of-box tests

identify old

batches

Page 5: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

New Hardware/Operating Systems

• Take advantage of 64 bit OS for memory

• Update IA server to 64 Bit Windows

• Strongly recommended to enhance performance

• Enables access to full 32-bit memory space (4 GB)

• Update at least some of your module servers to 64 bit Windows OS

• Some new IA modules will be strongly recommended to run on 64 bit Windows

5

DO!

DO!

2

Remember:

64-bit Windows

offers increased

performance and

security

Page 6: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Establish Performance Baseline

• Captiva Server Metrics for existing system

• DAL average execution time

• DAL average number of data requests

• DAL error count

• Processing message count

• VBA message thread queue length

• Database event queue length

• WMI Classes for this data

• Win32_PerfFormattedData_IA6Dal_IA6Dal

• Win32_PerfFormattedData_InputAccel_IA6Server_InputAccel

6

3 Did you know?

Reveille’s built-

in KPIs provide

these Captiva

Server Metrics

Page 7: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Test/ Prepare for Update

• Captiva Database Updates

• Create backup copy of current Captiva Database

• Run 7.1 database update program against this back up copy and check for any errors

• Scripts or Batch files to cleanly shutdown and restart on Captiva modules on all servers

• Shutdown Module services first

• Shutdown Captiva Server

• Apply updates

• Start Captiva Servers

• Start all module services

• Check all modules are connected

7

4 Don’t forget!

Reveille tests

can be used to

verify all

modules are

connected

Page 8: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Next step,

Successfully QA

Your Upgrade

Page 9: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Check update process

• Check update logs

• Database update logs

• Windows Event Logs on Captiva Module servers

• Start of Captiva Module servers

• Confirm all modules are connected to new Captiva IA servers

• Compare batch numbers in converted system to those prior to conversion of database

• Check Server Side performance against baseline data

• Process known set of batches and check for expected results.

• Check documents were created as expected

9

Note:

Use Reveille to verify

pre- and post-

upgrade performance

statistics & Reveille’s

out-of-box tests can

verify a test batch

runs successfully

5

Page 10: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Last, find out how

Reveille Can Help

Captiva metrics

At-a-glance

trending

Pre- / Post-

upgrade values

Thresholds

Page 11: Manage Your EMC Captiva 7.1 Upgrade with Application Performance Management

Take a Product Tour: http://reveillesoftware.com/product-tour/

user/ReveilleSoftware @ReveilleSoftwre

company/Reveille-Software