management pack for dell emc isilon - management packs for

43
Management Pack for Dell EMC Isilon Management Packs for vRealize Operations 4.0

Upload: others

Post on 03-Jun-2022

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Management Pack for Dell EMC Isilon - Management Packs for

Management Pack for Dell EMC Isilon

Management Packs for vRealize Operations 4.0

Page 2: Management Pack for Dell EMC Isilon - Management Packs for

You can find the most up-to-date technical documentation on the VMware website at:

https://docs.vmware.com/

VMware, Inc.3401 Hillview Ave.Palo Alto, CA 94304www.vmware.com

Copyright ©

2022 VMware, Inc. All rights reserved. Copyright and trademark information.

Management Pack for Dell EMC Isilon

VMware, Inc. 2

Page 3: Management Pack for Dell EMC Isilon - Management Packs for

Contents

1 Management Pack for Dell EMC Isilon 4

2 Getting Started (Dell EMC Isilon) 5

3 System Requirements (Dell EMC Isilon) 6Assigning Dell EMC Isilon User Permissions 6

Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon) 7

4 Installing the Management Pack (Dell EMC Isilon) 9

5 Configuring the Management Pack (Dell EMC Isilon) 10Creating a Credential (Dell EMC Isilon) 10

Creating an Adapter Instance (Dell EMC Isilon) 11

Validating Data Collection (Dell EMC Isilon) 12

6 Troubleshooting the Management Pack (Dell EMC Isilon) 14

7 Using the Management Pack (Dell EMC Isilon) 16Resource Kinds and Relationships (Dell EMC Isilon) 16

Inventory Tree (Traversal Spec) (Dell EMC Isilon) 18

Dashboards (Dell EMC Isilon) 18

Analysis Badges and Capacity Definitions (Dell EMC Isilon) 18

Alerts (Dell EMC Isilon) 19

Metrics (Dell EMC Isilon) 32

VMware, Inc. 3

Page 4: Management Pack for Dell EMC Isilon - Management Packs for

Management Pack for Dell EMC Isilon 1The VMware vRealize® Management Pack for Dell EMC Isilon is an embedded adapter for vRealize Operations (vROps), collecting performance, health, and availability data from your Dell EMC Isilon clustered network area storage (NAS) and providing predictive analytics and real-time monitoring information—all within the vRealize Operations user interface.

Notable Features

The Management Pack for Dell EMC Isilon provides the following notable features:

n Comprehensive monitoring dashboards:

n Dell EMC Isilon Overview – Get a bird's-eye view of the throughput KPIs and available vs. used disk space for your Isilon clusters, nodes, and interfaces

n Dell EMC Isilon Health Investigation – Drill down and quickly troubleshoot your Isilon resources using health status, active alerts, and metrics

n Dell EMC Isilon Performance – Gauge cluster and node performance via protocol throughput

n 200+ collected metrics for Dell EMC Isilon resources, including key metrics like Quota Usage Percentage, Average Disk Busy, and Total Connected Clients

n 250+ detailed alerts and notifications for events like SmartPool Over Capacity and Node IFS Filesystem Damage Detected

n vRealize Calculated IFS, SSD, Memory, and Disk Capacities – Predict when your Isilon storage system needs scaling

n VMware Datastore to Isilon NFS relationships – View the underlying Isilon storage infrastructure as it relates to your virtualized datastores

Getting Started

Wondering where to start? See our Chapter 2 Getting Started (Dell EMC Isilon) and Chapter 3 System Requirements (Dell EMC Isilon) topics for details.

VMware, Inc. 4

Page 5: Management Pack for Dell EMC Isilon - Management Packs for

Getting Started (Dell EMC Isilon) 2How the Management Pack Works

The Management Pack for Dell EMC Isilon accesses the OneFS API to import Isilon clustered NAS resources, relationships, metrics, and alerts into vRealize Operations to enable comprehensive monitoring and troubleshooting, while providing visibility into the virtual layer within vROps. Specifying a virtual IP during configuration allows the management pack to discover all nodes, returning data for each node, and enabling failover if the primary node goes down.

How to Get Started

To get started monitoring your Dell EMC Isilon storage devices from within vRealize Operations, see the following topics:

1 Review the System Requirements (Dell EMC Isilon) and ensure you have performed the necessary prerequisite tasks:

n Have your Isilon virtual IP, user name, and password available.

n Ensure you have completed Assigning Dell EMC Isilon User Permissions.

n If using SSL and you want the highest level of security available, ensure you have completed Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon).

2 Install the management pack. See: Chapter 4 Installing the Management Pack (Dell EMC Isilon).

3 Configure the management pack. See: Chapter 5 Configuring the Management Pack (Dell EMC Isilon). If you encounter any Test Connection errors when configuring, see: Chapter 6 Troubleshooting the Management Pack (Dell EMC Isilon).

4 Start using the management pack. See: Chapter 7 Using the Management Pack (Dell EMC Isilon).

VMware, Inc. 5

Page 6: Management Pack for Dell EMC Isilon - Management Packs for

System Requirements (Dell EMC Isilon) 3Before installing and configuring the management pack, ensure your system meets the following requirements:

vRealize Operations Requirements Dell EMC Isilon Requirements

Version(s) vRealize Operations 7.x & 8.x (Standard, Advanced, or Enterprise editions)

Dell EMC Isilon with OneFS 8.0.1

Important Active Directory authentication is only available on OneFS 8.1

Connection Dell EMC Isilon virtual IP (VIP)

Default Port:8080

Credentials Dell EMC IsilonUser Name & Password*

n *OneFS 8.1 Active Directory users should use user@domain when Creating a Credential (Dell EMC Isilon).

Important The least-privileged user (LPU) for the management pack must be assigned certain permissions in Isilon. See: Assigning Dell EMC Isilon User Permissions.

This chapter includes the following topics:

n Assigning Dell EMC Isilon User Permissions

n Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon)

Assigning Dell EMC Isilon User Permissions

In order to use all the features of the management pack, you must create a read-only monitoring user in Isilon with the following permissions assigned:

n Auth

n CloudPool

n Devices

n Events

n HDFS

n NFS

VMware, Inc. 6

Page 7: Management Pack for Dell EMC Isilon - Management Packs for

n Network

n Platform API

n Quota

n SMB

n SmartPools

n Statistics

What to do next

Chapter 4 Installing the Management Pack (Dell EMC Isilon)

Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon)

We recommend adding an SSL certificate for your Dell EMC Isilon host server to the vROps truststore to help provide an added level of security.

Important If you select Verify for the SSL Config Advanced Setting when Creating an Adapter Instance (Dell EMC Isilon), the management pack will attempt to verify the SSL certificate on your vROps system. Follow the steps below to add the certificate to the truststore.

To add the SSL certificate to your vROps truststore:

1 Obtain the SSL certificate for your Dell EMC Isilon host server from your Internet browser. Export the certificate as an X.509 Certificate (PEM).

2 Copy the certificate to your vROps machine.

3 Use ‘ssh’ to log in to the vROps machine as the root user, then run the following command:

Linux:

$VCOPS_BASE/jre/bin/keytool -import -alias <product_alias> -file /tmp/<certfile> -keystore "$VCOPS_DATA_VCOPS/user/conf/ssl/tcserver.truststore" -storepass `grep ssltruststorePassword /storage/vcops/user/conf/ssl/storePass.properties | sed s/ssltruststorePassword=//` -trustcacerts

Windows:

%VCOPS_BASE%\jre\bin\keytool -import -alias <product_alias> C:\path\to\certfile -keystore "%VCOPS_DATA_VCOPS%\user\conf\ssl\tcserver.truststore" -storepass <truststore_password> -trustcacerts

Parameter Descriptions:

n <product_alias> is a unique name for each key that you add (per host)

n <certfile> is the location where the cert file was saved

Management Pack for Dell EMC Isilon

VMware, Inc. 7

Page 8: Management Pack for Dell EMC Isilon - Management Packs for

4 Run the reboot command to re-start the vROps machine for the changes to take effect.

Management Pack for Dell EMC Isilon

VMware, Inc. 8

Page 9: Management Pack for Dell EMC Isilon - Management Packs for

Installing the Management Pack (Dell EMC Isilon) 4The Management Pack for Dell EMC Isilon is installed using a .pak file.

Procedure

1 Log in to vRealize Operations as an admin user.

2 From the top navigation bar, select Administration. In the left panel, the default Solutions

view will be selected. In the right panel, click the Add icon.

Note If you are using vROps 7.5, Solutions will have two subcategories: Configuration and Repository. Select Repository and scroll down to Other Management Packs and select Add a Management Pack to install a new management pack.

3 The Add Solution window will appear. Browse to the location of the saved .pak file, then click Upload.

4 Click Next when the upload has finished.

5 Read and accept the End User License Agreement (EULA), then click Next.

6 Click Finish when the installation process is complete.

VMware, Inc. 9

Page 10: Management Pack for Dell EMC Isilon - Management Packs for

Configuring the Management Pack (Dell EMC Isilon) 5Configuring the Management Pack for Dell EMC Isilon in vRealize Operations includes the following required tasks:

n Creating a Credential (Dell EMC Isilon)

n Creating an Adapter Instance (Dell EMC Isilon)

Note In addition, you may want to perform one or more of the following optional tasks to further configure the Management Pack for your specific needs:

n Validating Data Collection (Dell EMC Isilon) (optional)

This chapter includes the following topics:

n Creating a Credential (Dell EMC Isilon)

n Creating an Adapter Instance (Dell EMC Isilon)

n Validating Data Collection (Dell EMC Isilon)

Creating a Credential (Dell EMC Isilon)

One of the required configuration tasks for the Management Pack is to create a set of credentials in vROps.

Prerequisites

n Chapter 4 Installing the Management Pack (Dell EMC Isilon)

Procedure

1 From the top navigation bar, select Administration . In the left panel, expand the Management category and select Credentials.

2 Click the Add icon. In the Manage Credential window that appears, enter the following information:

n Credential name: A name for this set of credentials

n User Name: Dell EMC Isilon User Name*

VMware, Inc. 10

Page 11: Management Pack for Dell EMC Isilon - Management Packs for

n Password:Dell EMC Isilon Password

Important *OneFS 8.1+ Active Directory users should enter user@domain for the User Name field.

What to do next

Creating an Adapter Instance (Dell EMC Isilon)

Creating an Adapter Instance (Dell EMC Isilon)

Before you can begin using the Management Pack, you must create an adapter instance to identify the host from which the Management Pack will retrieve data.

Prerequisites

n Chapter 4 Installing the Management Pack (Dell EMC Isilon)

n Creating a Credential (Dell EMC Isilon)

Procedure

1 From the top navigation bar, select Administration. In the right panel, the Solutions view will be displayed.

2 Select Dell EMC Isilon from the Solutions list on the right.

3 Click the Configure icon. The Manage Solution window will appear.

Note Click the Add icon above the Instance Name list on the left to create multiple adapter instances.

4 In the Manage Solution window, enter the following information:

a Instance Settings:

n Display Name: A name for this particular instance of the Management Pack.

n Description: Optional, but it can be helpful to describe multiple instances of the Management Pack.

b Basic Settings:

n Host:We recommend specifying a virtual IP (VIP) for your Dell EMC Isilon system. Using the VIP will help ensure failover occurs if the primary node goes down.

n Credential: Select the credential you created when Creating a Credential (Dell EMC Isilon).

c Advanced Settings:

n Collector(s)/Groups: Default Collector/Group is automatically selected. Click the drop-down menu if you want to run the collection on a different node.

Management Pack for Dell EMC Isilon

VMware, Inc. 11

Page 12: Management Pack for Dell EMC Isilon - Management Packs for

n SSL Config: Options are No Verify (default value; SSL enabled/certificate not verified) and Verify (SSL enabled/certificate verified). If you select Verify, see: Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon).

n Port: Specify the port at which to make OneFS requests. Default port is 8080.

Note If using SSL, see our Customer Support Team's knowledge article Installing a Security Certificate for the Dell EMC Isilon Management Pack for information about default ports for Isilon security certificate installations.

n Collect Events: Select whether or not you want events to be collected. Default value is true to enable collection; select false if you want to disable event collection.

n Connection Timeout (Seconds):Enter the number of seconds to wait before closing a connection to the host if a response has not yet been received. Default value is 30 seconds.

n Max Events: Enter the maximum number of events to keep in vROps at any given time. Limiting the number of events will prevent performance from being negatively affected. Default value is 1000.

n Max Concurrent Requests: Enter the maximum number of concurrent REST requests to send at once. Limiting concurrent requests reduces the load on the target system, but increases overall collection time. Default value is 5.

n Max Retries: Enter the maximum number of times you want the management pack to attempt to connect to the host if an error occurs. Default value is 3.

n Collect Access Zone – Collect Network Interfaces: Select whether or not to collect each of the resources. Options are: Collect (default) or Off. If you select Off, REST requests will not be sent to the endpoints related to that resource kind.

n Support Autodiscovery: When you enable autodiscovery (set to True ; default setting), the Management Pack creates resources and relationships in vROps, then collects data for the discovered resources after the main collection query runs.

5 Click Test Connection to test the configured connection information. If you encounter any errors, see: Chapter 6 Troubleshooting the Management Pack (Dell EMC Isilon).

6 Click Save Settings and Close to save your adapter instance.

What to do next

n To validate data collection, see: Validating Data Collection (Dell EMC Isilon).

Validating Data Collection (Dell EMC Isilon)

After you add an adapter instance, you will most likely want to validate the data that it collects in vROps. Wait until one collection cycle is complete and the Collection Status for the adapter instance on the Solutions page shows as "Data Receiving".

Management Pack for Dell EMC Isilon

VMware, Inc. 12

Page 13: Management Pack for Dell EMC Isilon - Management Packs for

Prerequisites

n Creating an Adapter Instance (Dell EMC Isilon)

Procedure

1 From the top navigation bar, select Environment.

2 In the left panel, select All Objects , then expand the Dell EMC Isilon objects list.

3 Select a resource from the list, then click the All Metrics tab to select metrics and validate values against the data source.

What to do next

n To learn more about using the Management Pack, see: Chapter 7 Using the Management Pack (Dell EMC Isilon).

Management Pack for Dell EMC Isilon

VMware, Inc. 13

Page 14: Management Pack for Dell EMC Isilon - Management Packs for

Troubleshooting the Management Pack (Dell EMC Isilon) 6Once you have finished Chapter 4 Installing the Management Pack (Dell EMC Isilon) and Chapter 5 Configuring the Management Pack (Dell EMC Isilon), check the Collection Stateand Collection Status for the adapter instance on the Solutions page. If they show as Not Collecting or No Data Receiving, respectively, the following troubleshooting topics can help you diagnose and correct common problems with your adapter instance.

Test Connection Errors

When Creating an Adapter Instance (Dell EMC Isilon), click Test Connection after entering all of your configuration settings to ensure vROps can connect to the specified host.

The following errors are possible:

Connection Timeout. Check Host and/or Port.

Error Message: “Connection Timeout. Check Host and/or Port.”

Solution: Verify the Hostname and Port are correct when Creating an Adapter Instance (Dell EMC Isilon). If they are, increase the Connection Timeout to give the system enough time to connect to the system.

'Host' is invalid. Accepted Host formats are: [Host Name, Fully Qualified Domain Name, IPv4, IPv6].

Error Message: “'Host' is invalid. Accepted Host formats are: [Host Name, Fully Qualified Domain Name, IPv4, IPv6].”

Solution: When Creating an Adapter Instance (Dell EMC Isilon), ensure the Hostname is specified correctly (acceptable formats are domain name, FQDN, or IPv4/IPv6 address).

Username or Password is incorrect.

Error Message: “Username or Password is incorrect.”

Solution: When Creating a Credential (Dell EMC Isilon), ensure the Dell EMC Isilon user name and password specified are correct.

Failed to establish an SSL connection.

Error Message: “Failed to establish an SSL connection.”

VMware, Inc. 14

Page 15: Management Pack for Dell EMC Isilon - Management Packs for

Solution 1: If using SSL, ensure you have set the SSL Config Advanced Setting to No Verify or Verify when Creating an Adapter Instance (Dell EMC Isilon). If you selected Verify, also ensure that you've completed Adding an SSL Certificate to the vROps Truststore (Dell EMC Isilon).

Solution 2: If you are still encountering the error after completing Solution 1, check to see if the security certificate was installed into port 8081 (rather than 8080) on your Isilon system. See our Customer Support Team's knowledge article Installing a Security Certificate for the Dell EMC Isilon Management Pack to remedy the default port discrepancy, if needed.

Collection Errors

Problem: Some resources and/or metrics are not showing up every collection.

Solution: Check the logs to see if there are any reported timeout issues. If so, increase the Connection Timeout Advanced Setting to accommodate data retrieval. You may also consider reducing the number of Concurrent Requests. See: Creating an Adapter Instance (Dell EMC Isilon).

Adapter and Collector Log Files

You can review adapter errors in the adapter and collector log files, which can be viewed in the vROps UI or in an external log viewer.

n Adapter log files are located in the $VCOPS_BASE/user/log/adapters/DellEMCIsilonAdapter/ folder.

n Collector log files are located in the $VCOPS_BASE/user/log/ folder.

To set the base log level for the collector in vROps:

1 Navigate to Administration > Logs .

2 Expand the MASTER folder, then select the COLLECTOR folder.

3 Click the Edit Properties icon.

4 In the Root logger level drop-down menu, select the desired option:

n The default logging level is warning.

n To troubleshoot issues, set the logging level to info.

n To view detailed messages, including micro steps, queries, and returned results, set the logging level to debug.

Caution If you set the logging level todebug , log files can become large very quickly. Set the logging level todebug only for short periods of time.

For more information about viewing log files and modifying levels, refer to the vROps online help.

Management Pack for Dell EMC Isilon

VMware, Inc. 15

Page 16: Management Pack for Dell EMC Isilon - Management Packs for

Using the Management Pack (Dell EMC Isilon) 7The Management Pack for Dell EMC Isilon includes the following out-of-the-box features, harnessing the power of the vRealize Operations user interface:

n Resource Kinds and Relationships (Dell EMC Isilon)

n Inventory Tree (Traversal Spec) (Dell EMC Isilon)

n Dashboards (Dell EMC Isilon)

n Analysis Badges and Capacity Definitions (Dell EMC Isilon)

n Alerts (Dell EMC Isilon)

n Metrics (Dell EMC Isilon)

This chapter includes the following topics:

n Resource Kinds and Relationships (Dell EMC Isilon)

n Inventory Tree (Traversal Spec) (Dell EMC Isilon)

n Dashboards (Dell EMC Isilon)

n Analysis Badges and Capacity Definitions (Dell EMC Isilon)

n Alerts (Dell EMC Isilon)

n Metrics (Dell EMC Isilon)

Resource Kinds and Relationships (Dell EMC Isilon)

The Management Pack for Dell EMC Isilon creates Resource Kinds and Relationships (associations) for critical resources in your Isilon clustered NAS environment.

Resource Kinds

Performance, health, and availability data are collected for the following Dell EMC Isilon resource kinds:

1 Access Zone

2 Cloud Pool

VMware, Inc. 16

Page 17: Management Pack for Dell EMC Isilon - Management Packs for

3 Cluster

4 HDFS

5 Network Interface

6 NFS

7 Node

8 Quota

9 SMB

10 Storage Pool

Relationships

Relationships among discovered resources are also created by the Management Pack, which are depicted in the diagram below.

Dell EMC Isilon Relationships Diagram

Management Pack for Dell EMC Isilon

VMware, Inc. 17

Page 18: Management Pack for Dell EMC Isilon - Management Packs for

External Relationships

The Management Pack for Dell EMC Isilon can discover the following external relationships:

n VMware Datastore > NFS

Inventory Tree (Traversal Spec) (Dell EMC Isilon)

The Inventory Tree (Traversal Spec) feature in vROps allows you to easily navigate your Dell EMC Isilon environment. The hierarchical structure implicitly shows relationships among resources and enables quick drill-downs to root-cause issues.

To access your Dell EMC Isilon Inventory Tree, select Environment from the top navigation bar, then select Dell EMC Isilon from the left panel. Click on a resource from the Inventory Tree to populate details about the resource on the right.

Dashboards (Dell EMC Isilon)

Dashboards are the primary feature for monitoring and troubleshooting your Dell EMC Isilon clustered storage from within vRealize Operations.

The following dashboards are included in the Management Pack for Dell EMC Isilon:

n Dell EMC Isilon Health Investigation is the jumping-off point for investigating the health of your Isilon storage systems. This dashboard displays at-a-glance health status for all resources in your Isilon environment as well as metrics, relationships, and alerts specific to the resource selected from the Environment Overview widget.

n Dell EMC Isilon Overview provides a high-level overview of your Isilon storage systems. Select a Cluster, related Node, and related Interface from the widgets on the left to view graphs showing disk space used vs. space available, throughput KPIs, and Top Used Quotas by Percentage.

n Dell EMC Isilon Performance provides insight into the performance of your Isilon storage systems. Select a Cluster and related Node from the heatmap selectors to view throughput KPIs by protocol.

Analysis Badges and Capacity Definitions (Dell EMC Isilon)

Using the predictive analytics capabilities of vRealize Operations Analysis Badges through capacity definitions, the Management Pack for Dell EMC Isilon populates capacities as indicated in the table below.

Capacity Definitions List

Management Pack for Dell EMC Isilon

VMware, Inc. 18

Page 19: Management Pack for Dell EMC Isilon - Management Packs for

Container Use in Workload

Dell EMC Isilon Cluster

vRealize Calculated IFS SSD Capacity yes

vRealize Calculated IFS Capacity yes

Dell EMC Isilon Node

vRealize Calculated IFS SSD Capacity yes

vRealize Calculated IFS Capacity yes

vRealize Calculated Memory Capacity yes

Dell EMC Isilon Storage Pool

vRealize Calculated SSD Capacity yes

vRealize Calculated HDD Capacity yes

vRealize Calculated Disk Capacity yes

Alerts (Dell EMC Isilon)

The Management Pack for Dell EMC Isilon creates alerts (and in some cases provides recommended actions) based on various symptoms it detects in your Dell EMC Isilon Environment. See the table below for the list of alerts available in the Management Pack.

Name Description Symptom

Cluster has Authentication failure for CloudPool

This alert indicates that Cluster has Authentication failure for CloudPool.

Authentication failure for CloudPool

Cluster has Authorization failure for CloudPool

This alert indicates that Cluster has Authorization failure for CloudPool.

Authorization failure for CloudPool

Cluster has Bucket not found for CloudPool

This alert indicates that Cluster has Bucket not found for CloudPool.

Bucket not found for CloudPool

Cluster has CloudPools failed to verify provider certificate

This alert indicates that Cluster has CloudPools failed to verify provider certificate.

CloudPools failed to verify provider certificate

Cluster has Detected data corruption/integrity failure for CloudPool

This alert indicates that Cluster has Detected data corruption/integrity failure for CloudPool.

Detected data corruption/integrity failure for CloudPool

Cluster has CloudPools no usable account found policyid

This alert indicates that Cluster has CloudPools no usable account found policyid.

CloudPools no usable account found policyid

Cluster has CloudPools Network connection failed provider

This alert indicates that Cluster has CloudPools Network connection failed provider.

CloudPools Network connection failed provider

Management Pack for Dell EMC Isilon

VMware, Inc. 19

Page 20: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Cluster has Object not found for CloudPool

This alert indicates that Cluster has Object not found for CloudPool.

Object not found for CloudPool

Cluster has System is running out of file descriptors

This alert indicates that Cluster has System is running out of file descriptors.

System is running out of file descriptors

Cluster has Error calculating NVRAM Journal backup partition size, setting to default 512MB

This alert indicates that Cluster has Error calculating NVRAM Journal backup partition size.

Error calculating NVRAM Journal backup partition size, setting to default 512MB

Cluster has Error from verification of Journal superblock of Valid Mirror

This alert indicates that Cluster has Error from verification of Journal superblock of Valid Mirror.

Error from verification of Journal superblock of Valid Mirror

Cluster has NVRAM Journal is larger than journal backup partition, resizing NVRAM Journal

This alert indicates that Cluster has NVRAM Journal is larger than journal backup partition.

NVRAM Journal is larger than journal backup partition, resizing NVRAM Journal

Cluster has Backend Ethernet link running below capacity

This alert indicates that Cluster has Backend Ethernet link running below capacity.

Backend Ethernet link running below capacity

Cluster has Failure state on switch controller

This alert indicates that Cluster has Failure state on switch controller.

Failure state on switch controller

Cluster has Fan failure detected in switch

This alert indicates that Cluster has Fan failure detected in switch.

Fan failure detected in switch

Cluster has Power supply failure detected in switch

This alert indicates power supply failure detected in switch.

Power supply failure detected in switch

Cluster has Failed to talk with backend switch SNMP server

This alert indicates failed to talk with backend switch SNMP server.

Failed to talk with backend switch SNMP server

Cluster has Internal network link down This alert indicates that the internal network link down.

Internal network link down

Cluster has The expander is offline This alert indicates that the expander is offline.

The expander is offline

Cluster has Node offline This alert indicates node offline. Node offline

Cluster has Node is online This alert indicates that node is online. Node is online

Cluster has Node pool is underprotected

This alert indicates that a Info alert was raised in DellEMCIsilon.

Node pool is underprotected

Cluster has Node has been offline for over maximum allowed days

This alert indicates that node has been offline for over maximum allowed days.

Node has been offline for over maximum allowed days

Cluster has A SmartQuotas configuration error occurred in config file

This alert indicates that a martQuotas configuration error occurred in config file.

A SmartQuotas configuration error occurred in config file

Cluster has A SmartQuotas internal error occurred

This alert indicates that a SmartQuotas internal error occurred.

A SmartQuotas internal error occurred

Cluster has SmartQuotas notification for quota for user failed

This alert indicates that SmartQuotas notification for quota for user failed.

SmartQuotas notification for quota for user failed

Management Pack for Dell EMC Isilon

VMware, Inc. 20

Page 21: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Cluster has SmartQuotas report generation failed

This alert indicates SmartQuotas report generation failed.

SmartQuotas report generation failed

Cluster has SmartQuotas threshold violation on quota, domain

This alert indicates SmartQuotas threshold violation on quota, domain

SmartQuotas threshold violation on quota, domain

Cluster has The snapshot daemon failed to create scheduled snapshot

This alert indicates that the snapshot daemon failed to create scheduled snapshot

The snapshot daemon failed to create scheduled snapshot

Cluster has The snapshot daemon failed to delete an expired snapshot

This alert indicates that the snapshot daemon failed to delete an expired snapshot.

The snapshot daemon failed to delete an expired snapshot

Cluster has The snapshot daemon failed to remove a snapshot lock

This alert indicates that the snapshot daemon failed to remove a snapshot lock.

The snapshot daemon failed to remove a snapshot lock

Cluster has The snapshot reserve space is nearly full

This alert indicates that the snapshot reserve space is nearly full.

The snapshot reserve space is nearly full

Cluster has Snapshot daemon schedule policy config error

This alert indicates snapshot daemon schedule policy config error.

Snapshot daemon schedule policy config error

Cluster has Audit CEE server is unreachable

This alert indicates Audit CEE server is unreachable.

Audit CEE server is unreachable

Cluster has AVScan Infected File Found

This alert indicates AVScan Infected File Found.

AVScan Infected File Found

Cluster has Unhealthy boot disks, mirror is degraded or missing components

This alert indicates unhealthy boot disks, mirror is degraded or missing components.

Unhealthy boot disks, mirror is degraded or missing components

Cluster has Heartbeat Event This alert indicates Heartbeat Event. Heartbeat Event

Cluster has Cluster Software Event This alert indicates Cluster Software Event. Cluster Software Event

Cluster has Cluster contains a mix encrypting nodes and non-encrypting nodes

This alert indicates cluster contains a mix encrypting nodes and non-encrypting nodes.

Cluster contains a mix encrypting nodes and non-encrypting nodes

Cluster has Monthly status This alert indicates monthly status. Monthly status

Cluster has ESRS is disconnected from the gateway

This alert indicates that ESRS is disconnected from the gateway.

ESRS is disconnected from the gateway

Cluster has ESRS is unconfigured This alert indicates that ESRS is unconfigured.

ESRS is unconfigured

Cluster has A firmware update has not been completely applied

This alert indicates that a firmware update has not been completely applied.

A firmware update has not been completely applied

Cluster has Cluster needs to be restriped but FlexProtect is not running

This alert indicates cluster needs to be restriped but FlexProtect is not running.

Cluster needs to be restriped but FlexProtect is not running

Cluster has Job has failed This alert indicates job has failed. Job has failed

Cluster has Job phase begin This alert indicates job phase begin. Job phase begin

Management Pack for Dell EMC Isilon

VMware, Inc. 21

Page 22: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Cluster has Job phase end This alert indicates job phase end. Job phase end

Cluster has Job policy This alert indicates job policy. Job policy

Cluster has Job state This alert indicates job state. Job state

Cluster has Process was killed to free pages

This alert indicates that process was killed to free pages.

Process was killed to free pages

Cluster has Key Manager Init failed for cloudpools domain on node

This alert indicates Key Manager Init failed for cloudpools domain on node.

Key Manager Init failed for cloudpools domain on node

Cluster has Key Manager Init failed for SEDS domain on node

This alert indicates Key Manager Init failed for SEDS domain on node.

Key Manager Init failed for SEDS domain on node

Cluster has Licensing activation incomplete

This alert indicates Licensing activation incomplete.

Licensing activation incomplete

Cluster has License entitlements exceeded

This alert indicates License entitlements exceeded.

License entitlements exceeded

Cluster has Software license(s) expired This alert indicates that Software license(s) expired

Software license(s) expired

Cluster has Software license(s) will expire

This alert indicates that Software license(s) will expire.

Software license(s) will expire

Cluster has LWIO CA throttling This alert indicates LWIO CA throttling LWIO CA throttling

Cluster has LWIO memory throttling This alert indicates LWIO memory throttling.

LWIO memory throttling

Cluster has Process failed This alert indicates process failed. Process failed

Cluster has Process killed This alert indicates process killed. Process killed

Cluster has Mount request failed with error

This alert indicates mount request failed with error.

Mount request failed with error

Cluster has Mounted host lookup failed This alert indicates mounted host lookup failed.

Mountd host lookup failed

Cluster has NFS client may have inaccurate view of directory due to limitations of legacy 32-bit conversion. No way to safely translate readdirplus cookie to 32bits

This alert indicates NFS client may have inaccurate view of directory due to limitations of legacy 32-bit conversion. No way to safely translate readdirplus cookie to 32bits.

NFS client may have inaccurate view of directory due to limitations of legacy 32-bit conversion. No way to safely translate readdirplus cookie to 32bits.

Cluster has NFS identity query failed This alert indicates NFS identity query failed

NFS identity query failed

Cluster has SyncIQ resolved WORM committed file conflicts for policy

This alert indicates SyncIQ resolved WORM committed file conflicts for policy.

SyncIQ resolved WORM committed file conflicts for policy

Cluster has SyncIQ RPO exceeded for policy

This alert indicates SyncIQ RPO exceeded for policy.

SyncIQ RPO exceeded for policy

Cluster has SyncIQ software configuration error

This alert indicates SyncIQ software configuration error.

SyncIQ software configuration error

Management Pack for Dell EMC Isilon

VMware, Inc. 22

Page 23: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Cluster has Test event This alert indicates test event. Test event

Cluster has Test event 2 This alert indicates test event 2. Test event 2

Cluster has Upgrade Notice This alert indicates Upgrade Notice. Upgrade Notice

Cluster has Upgrade Finished This alert indicates Upgrade Finished. Upgrade Finished

Cluster has Upgrade Node Event This alert indicates Upgrade Node Event. Upgrade Node Event

Cluster has Upgrade Rollback Start This alert indicates Upgrade Rollback Start.

Upgrade Rollback Start

Cluster has Upgrade Start This alert indicates Upgrade Start. Upgrade Start

Cluster has AD server missing needed SPN(s); try 'isi auth ads spn check'

This alert indicates AD server missing needed SPN(s); try 'isi auth ads spn check'.

AD server missing needed SPN(s); try 'isi auth ads spn check'

Cluster has LDAP servers are offline. Authentication services may be interrupted

This alert indicates LDAP servers are offline. Authentication services may be interrupted.

LDAP servers are offline. Authentication services may be interrupted.

Cluster has NIS servers are offline. Authentication services may be interrupted

This alert indicates NIS servers are offline. Authentication services may be interrupted.

NIS servers are offline. Authentication services may be interrupted.

Cluster has Auth Upgrade Failure This alert indicates Auth Upgrade Failure. Auth Upgrade Failure

Cluster has Failed to parse idmap rules This alert indicates failed to parse idmap rules.

Failed to parse idmap rules

Cluster has Lwio Parameter Invalid This alert indicates Lwio Parameter Invalid. Lwio Parameter Invalid

Cluster has ICAP server misconfigured, unreachable or unresponsive

This alert indicates ICAP server misconfigured, unreachable or unresponsive.

ICAP server misconfigured, unreachable or unresponsive

Cluster has Storage transport problem This alert indicates storage transport problem.

Storage transport problem

Cluster has SyncIQ problem for policy This alert indicates SyncIQ problem for policy.

SyncIQ problem for policy

Cluster has Windows Authorization Event

This alert indicates Windows Authorization Event.

Windows Authorization Event

Cluster has Windows Identity Mapping Event

This alert indicates Windows Identity Mapping Event.

Windows Identity Mapping Event

Cluster has Windows Networking Event

This alert indicates Windows Networking Event.

Windows Networking Event

Node has Amp sensor out of spec in chassis

This alert indicates amp sensor out of spec in chassis.

Amp sensor out of spec in chassis

Node has Discrete sensor out of spec in chassis

This alert indicates discrete sensor out of spec in chassis.

Discrete sensor out of spec in chassis

Management Pack for Dell EMC Isilon

VMware, Inc. 23

Page 24: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Fan sensor out of spec in chassis

This alert indicates fan sensor out of spec in chassis.

Fan sensor out of spec in chassis

Node has Meters sensor out of spec in chassis

This alert indicates meters sensor out of spec in chassis.

Meters sensor out of spec in chassis

Node has Temperature sensor out of spec in chassis

This alert indicates temperature sensor out of spec in chassis.

Temperature sensor out of spec in chassis

Node has Voltage sensor out of spec in chassis

This alert indicates voltage sensor out of spec in chassis.

Voltage sensor out of spec in chassis

Node has Watt sensor out of spec in chassis

This alert indicates watt sensor out of spec in chassis.

Watt sensor out of spec in chassis

Node has Redundant power supply failure in chassis

This alert indicates redundant power supply failure in chassis.

Redundant power supply failure in chassis

Node has Discrete sensor out of spec in chassis.

This alert indicates discrete sensor out of spec in chassis.

Discrete sensor out of spec in chassis

Node has Sensor out of spec in chassis This alert indicates sensor out of spec in chassis.

Sensor out of spec in chassis

Node has Power Supply 1 Over Current out of spec in chassis

This alert indicates power supply 1 over current out of spec in chassis.

Power Supply 1 Over Current out of spec in chassis

Node has Power Supply 1 Fan Fail in chassis

This alert indicates power supply 1 fan fail in chassis.

Power Supply 1 Fan Fail in chassis

Node has Power Supply 1 Over Voltage in chassis

This alert indicates power supply 1 over voltage in chassis.

Power Supply 1 Over Voltage in chassis

Node has Redundant power supply 1 failure in chassis

This alert indicates redundant power supply 1 failure in chassis.

Redundant power supply 1 failure in chassis

Node has Power Supply 1 Under Voltage in chassis

This alert indicates power supply 1 under voltage in chassis.

Power Supply 1 Under Voltage in chassis

Node has Power Supply 2 Over Current out of spec in chassis

This alert indicates power supply 2 over current out of spec in chassis.

Power Supply 2 Over Current out of spec in chassis

Node has Power Supply 2 Fan Fail in chassis

This alert indicates power supply 2 fan fail in chassis.

Power Supply 2 Fan Fail in chassis

Node has Power Supply 2 Over Voltage in chassis

This alert indicates power supply 2 over voltage in chassis.

Power Supply 2 Over Voltage in chassis

Node has Redundant power supply 2 failure in chassis

This alert indicates redundant power supply 2 failure in chassis.

Redundant power supply 2 failure in chassis

Node has Power Supply 2 Under Voltage in chassis

This alert indicates power supply 2 under voltage in chassis.

Power Supply 2 Under Voltage in chassis

Node has Redundant power supply 1 failure in chassis

This alert indicates redundant power supply 1 failure in chassis.

Redundant power supply 1 failure in chassis

Node has Redundant power supply 2 failure in chassis

This alert indicates redundant power supply 2 failure in chassis.

Redundant power supply 2 failure in chassis

Node has Fan sensor out of spec in chassis

This alert indicates fan sensor out of spec in chassis.

Fan sensor out of spec in chassis

Management Pack for Dell EMC Isilon

VMware, Inc. 24

Page 25: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Drive sensor out of spec in chassis

This alert indicates drive sensor out of spec in chassis.

Drive sensor out of spec in chassis

Node has Drive sensor out of spec in chassis

This alert indicates drive sensor out of spec in chassis.

Drive sensor out of spec in chassis

Node has Sensor out of spec in chassis This alert indicates sensor out of spec in chassis.

Sensor out of spec in chassis

Node has Fan sensor out of spec in chassis

This alert indicates fan sensor out of spec in chassis.

Fan sensor out of spec in chassis

Node has Battery sensor out of spec in chassis

This alert indicates battery sensor out of spec in chassis.

Battery sensor out of spec in chassis

Node has Temperature sensor out of spec in chassis

This alert indicates temperature sensor out of spec in chassis.

Temperature sensor out of spec in chassis

Node has Sensor is not providing a reading

This alert indicates sensor is not providing a reading.

Sensor is not providing a reading

Node has Temperature sensor out of spec in chassis

This alert indicates temperature sensor out of spec in chassis.

Temperature sensor out of spec in chassis

Node has Temperature sensor out of spec in chassis

This alert indicates temperature sensor out of spec in chassis.

Temperature sensor out of spec in chassis

Node has Physical Memory low This alert indicates Physical Memory low. Physical Memory low

Node has Redundant power supply failure in chassis

This alert indicates redundant power supply failure in chassis.

Redundant power supply failure in chassis

Node has Redundant power supply failure on expansion chassis

This alert indicates redundant power supply failure on expansion chassis.

Redundant power supply failure on expansion chassis

Node has Adaptive cooling event detected

This alert indicates adaptive cooling event detected.

Adaptive cooling event detected

Node has Journal protection in the event of a power failure not enabled

This alert indicates Journal protection in the event of a power failure not enabled.

Journal protection in the event of a power failure not enabled

Node has Battery Backup Unit fault detected

This alert indicates Battery Backup Unit fault detected.

Battery Backup Unit fault detected

Node has Compute node fault detected

This alert indicates compute node fault detected.

Compute node fault detected

Node has Corrected Hardware Error This alert indicates corrected hardware error.

Corrected Hardware Error

Node has DIMM fault detected This alert indicates DIMM fault detected. DIMM fault detected

Node has Drive interface board fault detected

This alert indicates drive interface board fault detected.

Drive interface board fault detected

Node has External fault detected This alert indicates external fault detected. External fault detected

Node has Fan fault detected This alert indicates fan fault detected. Fan fault detected

Node has I2C fault detected This alert indicates I2C fault detected. I2C fault detected

Management Pack for Dell EMC Isilon

VMware, Inc. 25

Page 26: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Internal fault detected This alert indicates internal fault detected. Internal fault detected

Node has IO module fault detected This alert indicates IO module fault detected.

IO module fault detected

Node has Local journal not in protected state

This alert indicates local journal not in protected state.

Local journal not in protected state

Node has Local Baseboard Management Controller unresponsive

This alert indicates Local Baseboard Management Controller unresponsive.

Local Baseboard Management Controller unresponsive

Node has Internal M.2 drive fault detected

This alert indicates internal M.2 drive fault detected.

Internal M.2 drive fault detected fault detected

Node has Midplane fault detected This alert indicates midplane fault detected Midplane fault detected

Node has MNVI protocol establishment error

This alert indicates MNVI protocol establishment error.

"MNVI protocol establishment error

Node has NTB Link outage This alert indicates NTB link outage. NTB Link outage

Node has Non-transparent bridge fault detected

This alert indicates non-transparent bridge fault detected.

Non-transparent bridge fault detected

Node has Peer Baseboard Management Controller unresponsive

This alert indicates Peer Baseboard Management Controller unresponsive

Peer Baseboard Management Controller unresponsive

Node has Unable to restore journal after powering up the node

This alert indicates unable to restore journal after powering up the node.

"Unable to restore journal after powering up the node

Node has Power supply redundancy fault

This alert indicates a power supply redundancy fault.

Power supply redundancy fault

Node has Power supply fault detected This alert indicates power supply fault detected.

Power supply fault detected

Node has Sensor out of spec in chassis This alert indicates sensor out of spec in chassis.

Sensor out of spec in chassis

Node has Sensor out of spec in chassis This alert indicates sensor out of spec in chassis.

Sensor out of spec in chassis

Node has Power Supply 1 AC Fail in chassis

This alert indicates power supply 1 AC fail in chassis.

Power Supply 1 AC Fail in chassis

Node has Power Supply 1 Over Current out of spec in chassis

This alert indicates power supply 1 over current out of spec in chassis.

"Power Supply 1 Over Current out of spec in chassis

Node has Power Supply 1 Fan Fail in chassis

This alert indicates power supply 1 fan fail in chassis.

Power Supply 1 Fan Fail in chassis

Node has Power Supply 1 Over Voltage in chassis

This alert indicates power supply 1 over voltage in chassis.

Power Supply 1 Over Voltage in chassis

Node has Power Supply 1 Under Voltage in chassis

This alert indicates power supply 1 under voltage in chassis.

Power Supply 1 Under Voltage in chassis

Node has Power Supply 2 AC Fail in chassis

This alert indicates power supply 2 AC fail in chassis.

Power Supply 2 AC Fail in chassis

Node has Power Supply 2 Over Current out of spec in chassis

This alert indicates power supply 2 over current out of spec in chassis.

Power Supply 2 Over Current out of spec in chassis

Management Pack for Dell EMC Isilon

VMware, Inc. 26

Page 27: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Power Supply 2 Fan Fail in chassis

This alert indicates power supply 2 fan fail in chassis.

Power Supply 2 Fan Fail in chassis

Node has Power Supply 2 Over Voltage in chassis

This alert indicates power supply 2 over voltage in chassis.

Power Supply 2 Over Voltage in chassis

Node has Power Supply 2 Under Voltage in chassis

This alert indicates power supply 2 under voltage in chassis.

Power Supply 2 Under Voltage in chassis

Node has Redundant power supply failure in chassis

This alert indicates redundant power supply failure in chassis.

Redundant power supply failure in chassis

Node has NVRAM arm vault fail in chassis

This alert indicates NVRAM arm vault fail in chassis.

NVRAM arm vault fail in chassis

Node has NVRAM controller fail in chassis

This alert indicates NVRAM controller fail in chassis.

NVRAM controller fail in chassis

Node has NVRAM DMA state machine entered error state in chassis

This alert indicates NVRAM DMA state machine entered error state in chassis.

NVRAM DMA state machine entered error state in chassis

Node has NVRAM DMA ring initialization failure in chassis

This alert indicates NVRAM DMA state machine entered readonly state in chassis.

NVRAM DMA ring initialization failure in chassis

Node has NVRAM DMA state machine entered readonly state in chassis

This alert indicates NVRAM DMA state machine entered readonly state in chassis.

NVRAM DMA state machine entered readonly state

Node has NVRAM DMA timeout failure in chassis

This alert indicates NVRAM DMA timeout failure in chassis.

NVRAM DMA timeout failure in chassis

Node has NVRAM Correctable (single-bit) ECC in chassis

This alert indicates NVRAM correctable (single-bit) ECC in chassis.

NVRAM Correctable (single-bit) ECC in chassis

Node has NVRAM Uncorrectable (multi-bit) ECC Error in chassis

This alert indicates NVRAM uncorrectable (multi-bit) ECC Error in chassis.

NVRAM Uncorrectable (multi-bit) ECC Error in chassis

Node has NVRAM IDENTIFY ping fail in chassis

This alert indicates NVRAM IDENTIFY ping fail in chassis.

NVRAM IDENTIFY ping fail in chassis

Node has NVRAM invalidate nvram fail in chassis

This alert indicates NVRAM invalidate nvram fail in chassis.

NVRAM invalidate nvram fail in chassis

Node has NVRAM async event invalid log page in chassis

This alert indicates NVRAM async event invalid log page in chassis.

NVRAM async event invalid log page in chassis

Node has NVRAM interrupt (MSI) initialization failure in chassis

This alert indicates NVRAM interrupt (MSI) initialization failure in chassis.

NVRAM interrupt (MSI) initialization failure in chassis

Node has NVRAM msi-x resources failure in chassis

This alert indicates NVRAM msi-x resources failure in chassis.

NVRAM msi-x resources failure in chassis

Node has NVRAM SoC firmware detected DMA execution failure in chassis

This alert indicates NVRAM SoC firmware detected DMA execution failure in chassis.

NVRAM SoC firmware detected DMA execution failure in chassis

Node has NVRAM SoC firmware detected DMA fetch failure in chassis

This alert indicates NVRAM SoC firmware detected DMA fetch failure in chassis.

NVRAM SoC firmware detected DMA fetch failure in chassis

Node has NVRAM SoC firmware detected DMA stall failure in chassis

This alert indicates NVRAM SoC firmware detected DMA stall failure in chassis.

NVRAM SoC firmware detected DMA stall failure in chassis

Management Pack for Dell EMC Isilon

VMware, Inc. 27

Page 28: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has NVRAM SoC firmware panic failure in chassis

This alert indicates NVRAM SoC firmware panic failure in chassis.

NVRAM SoC firmware panic failure in chassis

Node has NVRAM SoC firmware version failure in chassis

This alert indicates NVRAM SoC firmware version failure in chassis.

NVRAM SoC firmware version failure in chassis

Node has NVRAM SoC PCIe link width negotiation failure in chassis

This alert indicates NVRAM SoC PCIe link width negotiation failure in chassis.

NVRAM SoC PCIe link width negotiation failure in chassis

Node has NVRAM SoC PCIe link speed negotiation failure in chassis

This alert indicates NVRAM SoC PCIe link speed negotiation failure in chassis.

NVRAM SoC PCIe link speed negotiation failure in chassis

Node has NVRAM SoC missing firmware failure in chassis

This alert indicates NVRAM SoC missing firmware failure in chassis.

NVRAM SoC missing firmware failure in chassis

Node has NVRAM SoC Power-On-Selftest (POST) failure in chassis

This alert indicates NVRAM SoC Power-On-Selftest (POST) failure in chassis.

NVRAM SoC Power-On-Selftest (POST) failure in chassis

Node has NVRAM SoC reset failure in chassis

This alert indicates NVRAM SoC reset failure in chassis.

"NVRAM SoC reset failure in chassis

Node has NVRAM SRAM correctable (single-bit) ECC error in chassis

This alert indicates NVRAM SRAM correctable (single-bit) ECC error in chassis.

NVRAM SRAM correctable (single-bit) ECC error in chassis

Node has Redundant power supply failure in chassis

This alert indicates redundant power supply failure on chassis.

Redundant power supply failure in chassis

Node has Redundant power supply failure in chassis

This alert indicates redundant power supply failure on chassis.

Redundant power supply failure in chassis

Node has Redundant power supply failure on expansion chassis

This alert indicates redundant power supply failure on expansion chassis.

Redundant power supply failure on expansion chassis

Node has NVRAM battery has failed in chassis

This alert indicates that a NVRAM battery has failed in chassis.

NVRAM battery has failed in chassis

Node has Node's Chassis Management Controller (CMC) is unresponsive in chassis. Hardware is no longer being monitored

This alert indicates that a node's Chassis Management Controller (CMC) is unresponsive in chassis. Hardware is no longer being monitored.

Node's Chassis Management Controller (CMC) is unresponsive in chassis. Hardware is no longer being monitored.

Node has DMI log entry in chassis slot This alert indicates that a node has DMI log entry in chassis slot.

DMI log entry in chassis slot

Node has DMI read failure in chassis This alert indicates that a node has DMI read failure in chassis.

DMI read failure in chassis

Node has Policy Error -- Correctable ECC error policy violation

This alert indicates that a node has a policy error -- correctable ECC error policy violation.

Policy Error -- Correctable ECC error policy violation

Node has Node contains an 812 (3/4 chassis) SKU in chassis

This alert indicates that a node contains an 812 (3/4 chassis) SKU in chassis.

Node contains an 812 (3/4 chassis) SKU in chassis

Node has Firmware update failed for device

This alert indicates that a firmware update failed for device.

Firmware update failed for device

Node has Hardware error - I2C bus hang has occurred in chassis

This alert indicates that an I2C bus hang has occurred in chassis.

Hardware error - I2C bus hang has occurred in chassis

Management Pack for Dell EMC Isilon

VMware, Inc. 28

Page 29: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has NVRAM error has occurred in chassis

This alert indicates that a NVRAM error has occurred in chassis.

NVRAM error has occurred in chassis

Node has Chassis has been opened in chassis

This alert indicates that a chassis has been opened in chassis.

Chassis has been opened in chassis

Node has A drive power zone fuse on the expander board has failed

This alert indicates that a drive power zone fuse on the expander board has failed.

A drive power zone fuse on the expander board has failed

Node has Node has wrong drive (SSD/HDD) ratio in chassis

This alert indicates that a node has wrong drive ratio (SSD/HDD) in chassis.

Node has wrong drive (SSD/HDD) ratio in chassis

Node has Redundant power supply 1 failure in chassis

This alert indicates redundant power supply 1 failure in chassis.

Redundant power supply 1 failure in chassis

Node has Redundant power supply 2 failure in chassis

This alert indicates redundant power supply 2 failure in chassis.

Redundant power supply 2 failure in chassis

Node has Device is not a supported boot disk

This alert indicates that a device is not a supported boot disk.

Device is not a supported boot disk

Node has Excessive boot flash drive writing detected

This alert indicates that excessive boot flash drive writing has been detected.

Excessive boot flash drive writing detected

Node has Device disconnected. Boot mirror is critical

This alert indicates that a Info alert was raised in DellEMCIsilon.

Device disconnected. Boot mirror is critical.

Node has A required mirror is missing on the boot drives

This alert indicates that a node has a required mirror missing on the boot drives.

A required mirror is missing on the boot drives

Node has Only one boot disk is remaining in the mirror

This alert indicates that only one boot disk is remaining in the mirror.

Only one boot disk is remaining in the mirror

Node has Drive was inserted in a bay that is disabled

This alert indicates that a drive was inserted in a bay that is disabled.

Drive was inserted in a bay that is disabled

Node has Disk sector error This alert indicates that a node has disk sector error.

Disk sector error

Node has Disk ECC list is full This alert indicates that a disk ECC list is full.

Disk ECC list is full

Node has Failed to crypto-erase drive This alert indicates that a node has failed to crypto-erase the drive.

Failed to crypto-erase drive

Node has The drive was not formatted correctly and was not added to the filesystem

This alert indicates that a drive was not formatted correctly and was not added to the filesystem.

The drive was not formatted correctly and was not added to the filesystem

Node has The write-cache for the drive is enabled

This alert indicates that the write-cache for the drive is enabled.

The write-cache for the drive is enabled

Node has Drive is insecure This alert indicates that a drive is insecure. "Drive is insecure

Node has Drive has an invalid write-cache setting and has been smartfailed

This alert indicates that a drive has an invalid write-cache setting and has been smartfailed.

Drive has an invalid write-cache setting and has been smartfailed

Node has Disk Repair Started This alert indicates that a node has disk repair started.

Disk Repair Started

Management Pack for Dell EMC Isilon

VMware, Inc. 29

Page 30: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Disk Repair Complete. Insert new drive into bay

This alert indicates that a disk repair has been completed and a new drive should be inserted into the bay.

Disk Repair Complete. Insert new drive into bay.

Node has There is at least one smartpool at or over capacity

This alert indicates that at least one smartpool is at or over capacity.

There is at least one smartpool at or over capacity

Node has The SmartPools upgrade has not completed

This alert indicates that a node's SmartPools upgrade has not completed.

The SmartPools upgrade has not completed

Node has A drive that previously failed was inserted as a replacement

This alert indicates that a drive that previously failed was inserted as a replacement.

A drive that previously failed was inserted as a replacement

Node has Disk Repair Complete. Replace the drive

This alert indicates that a node has completed disk repair and the drive needs to be replaced.

Disk Repair Complete. Replace the drive.

Node has /(root) partition is near capacity

This alert indicates that a node's /(root) partition is near capacity.

/(root) partition is near capacity

Node has Disk Repair Completed: The drive is ready to be replaced

This alert indicates that a node has completed disk repair and is ready to be replaced.

Disk Repair Completed: The drive is ready to be replaced

Node has Disk Repair Completed: The sled contains a smartfailed drive

This alert indicates that a node has completed disk repair. The sled contained a smartfailed drive.

Disk Repair Completed: The sled contains a smartfailed drive

Node has A FlexProtect job is in progress

This alert indicates that a node has a FlexProtect job in progress.

A FlexProtect job is in progress

Node has The SSD drives are near capacity

This alert indicates that a node has SSD drives near capacity.

The SSD drives are near capacity

Node has Drive Stall This alert indicates that a node has a drive that stalled.

Drive Stall

Node has One or more drives are not healthy

This alert indicates that a node has one or more drives that are not healthy.

One or more drives are not healthy

Node has Drive has unknown firmware This alert indicates that a drive in the node has unknown firmware.

Drive has unknown firmware

Node has Drive is unknown model This alert indicates that a drive in the node is an unknown model.

Drive is unknown model

Node has Unprovisionable drive(s) This alert indicates that a node has one or more unprovisionable drives.

Unprovisionable drive(s)

Node has A used drive from another cluster was inserted as a replacement

This alert indicates that a used drive from another cluster was inserted as a replacement for a node.

A used drive from another cluster was inserted as a replacement

Node has /var/crash partition is near capacity

This alert indicates that a node's /var/crash partition is near capacity.

/var/crash partition is near capacity

Node has /var partition near capacity This alert indicates that a node's /var partition is near capacity.

/var partition near capacity

Management Pack for Dell EMC Isilon

VMware, Inc. 30

Page 31: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has The drive was inserted into a bay that contains another drive that is in the process of smartfailing

This alert indicates that a node has a drive inserted into a bay that contains another drive that is in the process of smartfailing.

The drive was inserted into a bay that contains another drive that is in the process of smartfailing

Node has Drive is the wrong type This alert indicates that a node has a drive of the wrong type.

Drive is the wrong type

Node has Drive has the wrong write-cache settings for this platform was inserted as a replacement

This alert indicates that a node has a drive with the wrong write-cache settings for this platform that was inserted as a replacement.

Drive has the wrong write-cache settings for this platform was inserted as a replacement

Node has Drive model, firmware has unsupported block length

This alert indicates that a node has a drive model with firmware that has an unsupported block length.

Drive model, firmware has unsupported block length

Node has Drive has wrong firmware This alert indicates that a node has a drive with the wrong firmware.

Drive has wrong firmware

Node has A used drive from another node in this cluster was inserted as a replacement

This alert indicates that a node has a used drive from another node in this cluster that was inserted as a replacement.

A used drive from another node in this cluster was inserted as a replacement

Node has Drive bay threshold exceeded

This alert indicates that a node has exceeded the drive bay threshold.

Drive bay threshold exceeded

Node has Missing config file for drive model

This alert indicates that a node has a missing config file for drive model.

Missing config file for drive model

Node has Drive SMART status has exceeded threshold

This alert indicates that a node has drive SMART status that has exceeded threshold.

Drive SMART status has exceeded threshold

Node has A fault was detected in a sled

This alert indicates that a a fault was detected in a sled.

A fault was detected in a sled

Node has The drive is missing. Starting disk repair for the missing drive

This alert indicates that a drive is missing from a node. Disk repair for the missing drive will be started automatically.

The drive is missing. Starting disk repair for the missing drive.

Node has Sled has been removed from the chassis for longer than the timeout limit

This alert indicates that a node has a sled that has been removed from the chassis for longer than the timeout.

Sled has been removed from the chassis for longer than the timeout limit.

Node has The sled service timeout limit has expired

This alert indicates that a node's sled service timeout limit has expired.

The sled service timeout limit has expired.

Node has A sled was unexpectedly removed from the chassis

This alert indicates that a node has a sled that was unexpectedly removed from the chassis.

A sled was unexpectedly removed from the chassis.

Node has Node pool(s) with an unbalanced SSD count

This alert indicates that a node has pool(s) with an unbalanced SSD count.

Node pool(s) with an unbalanced SSD count

Node has External network problem This alert indicates that a node has an external network problem.

External network problem

Node has IFS filesystem damage detected

This alert indicates that IFS filesystem damage has been detected on a node.

IFS filesystem damage detected

Management Pack for Dell EMC Isilon

VMware, Inc. 31

Page 32: Management Pack for Dell EMC Isilon - Management Packs for

Name Description Symptom

Node has Hardware monitoring failure This alert indicates that a node has a hardware monitoring failure.

Hardware monitoring failure

Node has Node overheating This alert indicates that a node is overheating.

Node overheating

Node has Physical memory low This alert indicates that a node has low physical memory available.

Physical memory low

Node has Power supply problem This alert indicates that a node has a power supply problem.

Power supply problem

Node has Node rebooted This alert indicates that a node rebooted. Node rebooted

Node has Node failing to reboot This alert indicates that a node is failing to reboot.

Node failing to reboot

Node has Node below operating temperature

This alert indicates that a node is below operating temperature.

Node below operating temperature

Metrics (Dell EMC Isilon)

The Management Pack for Dell EMC Isilon collects the metrics listed in the table below, according to Dell EMC Isilon resource kinds.

Download metrics list as .csv file

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Access Zone

Details Groupnet string Groupnet identifier

Dell EMC Isilon Access Zone

Details Name string Specifies the access zone name.

Dell EMC Isilon Access Zone

Details Path string Specifies the access zone base directory path.

Dell EMC Isilon Access Zone

Details System string True if the access zone is built-in.

Dell EMC Isilon Access Zone

Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon Access Zone

Relationships Hadoop FS Children string List of child Hadoop FS resources

Dell EMC Isilon Access Zone

Relationships NFS Children string List of child NFS resources

Dell EMC Isilon Access Zone

Relationships SMB Children string List of child SMB resources

Dell EMC Isilon Cloud Pool

Details Description string A brief description of this pool

Management Pack for Dell EMC Isilon

VMware, Inc. 32

Page 33: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Cloud Pool

Details Name string A unique name for this pool

Dell EMC Isilon Cloud Pool

Details State string Indicates whether this pool is in a good state ("OK") or disabled ("disabled")

Dell EMC Isilon Cloud Pool

Details Type string The type of cloud protocol required. E.g., "isilon" for EMC Isilon, "ecs" for EMC ECS Appliance, "virtustream" for Virtustream Storage Cloud, "azure" for Microsoft Azure and "s3" for Amazon S3

Dell EMC Isilon Cloud Pool

Details Vendor string A string identifier of the cloud services vendor

Dell EMC Isilon Cloud Pool

Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon Cluster

CPU CPU Nice Average float Cluster average of nice CPU usage

Dell EMC Isilon Cluster

CPU CPU Nice Maximum float Maximum cluster average of nice CPU usage

Dell EMC Isilon Cluster

CPU CPU System Average

float Cluster average of sytem CPU usage

Dell EMC Isilon Cluster

CPU CPU System Maximum

float Maximum cluster average of sytem CPU usage

Dell EMC Isilon Cluster

CPU CPU Usage float The percentage CPU utilization.

Dell EMC Isilon Cluster

CPU CPU User Average float Cluster average of user CPU usage

Dell EMC Isilon Cluster

CPU CPU User Maximum float Maximum cluster average of user CPU usage

Dell EMC Isilon Cluster

Details Compliance Mode Enabled

string If true, the cluster is in compliance mode. Compliance mode clusters do not allow root access and have stricter WORM (Write Once Read Many) features for retaining data in compliance with U.S. Securities and Exchange Commission rule 17a-4.

Dell EMC Isilon Cluster

Details Description string Customer configurable description.

Dell EMC Isilon Cluster

Details External IPs string External IPs

Dell EMC Isilon Cluster

Details Is Virtual string true if the cluster is deployed on a desktop VMWorkstation

Dell EMC Isilon Cluster

Details Local Serial Number string Device serial number of the queried node.

Management Pack for Dell EMC Isilon

VMware, Inc. 33

Page 34: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Cluster

Details Name string The name of the resource.

Dell EMC Isilon Cluster

Details Node Count integer Number of configured nodes in the cluster

Dell EMC Isilon Cluster

Details Path string Timezone hierarchical name.

Dell EMC Isilon Cluster

Details Release Version string Kernel release number.

Dell EMC Isilon Cluster

Details Revision string OneFS build number.

Dell EMC Isilon Cluster

Details Type string Kernel release type.

Dell EMC Isilon Cluster

Disk Disk Busy float Average busy

Dell EMC Isilon Cluster

Disk Disk In float Traffic to disk.

Dell EMC Isilon Cluster

Disk Disk Traffic Out float Traffic from disk.

Dell EMC Isilon Cluster

Disk Estimated Deduplicated Space

integer Estimated deduplicated space.

Dell EMC Isilon Cluster

Disk IFS Ops In Rate float Cumulative operation rate into /ifs

Dell EMC Isilon Cluster

Disk IFS Ops Out Rate float Cumulative operation rate out of /ifs

Dell EMC Isilon Cluster

Disk IFS Percent Avail float Percent of /ifs filesystem available for storage

Dell EMC Isilon Cluster

Disk IFS Percent Free float Percent of /ifs filesystem free for the system

Dell EMC Isilon Cluster

Disk IFS Percent Used float Percent of /ifs filesystem used for storage

Dell EMC Isilon Cluster

Disk IFS Reserved Drive integer Reserved space per drive

Dell EMC Isilon Cluster

Disk IFS Reserved Snapshots

integer Space reserved for snapshots

Dell EMC Isilon Cluster

Disk IFS Space Available integer Space available in the /ifs filesystem

Dell EMC Isilon Cluster

Disk IFS Space Free integer Space free in the /ifs filesystem

Dell EMC Isilon Cluster

Disk IFS Space Total integer Total space in the /ifs filesystem

Dell EMC Isilon Cluster

Disk IFS Space Used integer Space used in the /ifs filesystem

Management Pack for Dell EMC Isilon

VMware, Inc. 34

Page 35: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Cluster

Disk IFS Throughput In Rate

float Cumulative throughput rate into /ifs

Dell EMC Isilon Cluster

Disk IFS Throughput In Rate Max

float Cumulative maximum throughput rate into /ifs

Dell EMC Isilon Cluster

Disk IFS Throughput Out Rate

float Cumulative throughput rate out of /ifs

Dell EMC Isilon Cluster

Disk IFS Throughput Out Rate Max

float Cumulative maximum throughput rate out of /ifs

Dell EMC Isilon Cluster

Disk Logical Deduplicated Space

integer The logical space deduplicated.

Dell EMC Isilon Cluster

Disk SSD Free float Percent of SSD space in /ifs filesystem free for the system

Dell EMC Isilon Cluster

Disk SSD Space Free integer Free space on SSDs in the /ifs filesystem

Dell EMC Isilon Cluster

Disk SSD Space Total integer Total space on SSDs in the /ifs filesystem

Dell EMC Isilon Cluster

Disk SSD Space Used integer Used space on SSDs in the /ifs filesystem

Dell EMC Isilon Cluster

Disk SSD Used float Percent of SSD space in /ifs filesystem used for storage

Dell EMC Isilon Cluster

Disk Total Space Used integer Space Used on the cluster.

Dell EMC Isilon Cluster

Network FTP Throughput float The total throughput for FTP operations.

Dell EMC Isilon Cluster

Network HDFS Throughput float The total throughput for HDFS operations.

Dell EMC Isilon Cluster

Network HTTP Throughput float The total throughput for HTTP operations.

Dell EMC Isilon Cluster

Network NFS Throughput float The total throughput for NFS (NFS3 & NFS4) operations.

Dell EMC Isilon Cluster

Network Network In Rate float In Throughput for all external interfaces

Dell EMC Isilon Cluster

Network Network Out Rate float Out Throughput for all external interfaces

Dell EMC Isilon Cluster

Network Network Traffic In float Incoming network traffic for all operations.

Dell EMC Isilon Cluster

Network Network Traffic Out float Outgoing network traffic throughput for all operations.

Dell EMC Isilon Cluster

Network SMB Throughput float The total throughput for SMB (SMB1 & SMB2) operations.

Dell EMC Isilon Cluster

Network Total Protocol Throughput

float The total throughput for all protocols listed.

Management Pack for Dell EMC Isilon

VMware, Inc. 35

Page 36: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Cluster

Status Nodes Currently Down

integer Number of cluster nodes currently down

Dell EMC Isilon Cluster

Status Nodes Currently Up integer Number of cluster nodes currently up

Dell EMC Isilon Cluster

Relationships Access Zone Children

string List of child Access Zone resources

Dell EMC Isilon Cluster

Relationships Cloud Pool Children string List of child Cloud Pool resources

Dell EMC Isilon Cluster

Relationships Hadoop FS Children string List of child Hadoop FS resources

Dell EMC Isilon Cluster

Relationships NFS Children string List of child NFS resources

Dell EMC Isilon Cluster

Relationships Node Children string List of child Node resources

Dell EMC Isilon Cluster

Relationships Quota Children string List of child Quota resources

Dell EMC Isilon Cluster

Relationships SMB Children string List of child SMB resources

Dell EMC Isilon Cluster

Relationships Storage Pool Children

string List of child Storage Pool resources

Dell EMC Isilon Hadoop FS

Details IP Pools string Array of IP pool names to use for serving clients from client_ip_ranges.

Dell EMC Isilon Hadoop FS

Details Name string Name of the rack

Dell EMC Isilon Hadoop FS

Relationships Access Zone Parents

string List of parent Access Zone resources

Dell EMC Isilon Hadoop FS

Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon Network Interface

Details IP Addresses string List of IP addresses.

Dell EMC Isilon Network Interface

Details LNN integer Logical Node Number

Dell EMC Isilon Network Interface

Details NIC Name string NIC name

Dell EMC Isilon Network Interface

Details Name string The name of the interface.

Dell EMC Isilon Network Interface

Details Status string Status of the interface

Management Pack for Dell EMC Isilon

VMware, Inc. 36

Page 37: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Network Interface

Details Type string Interface type. The '*gige' types stand for 'gigabit ethernet'. 'gige' itself is occasionally also referred to in other places as 'ext' for 'external'. 'ib' and 'ib_qdr' are internal Infiniband interface types. 'vlan' and 'vmxnet3' are virtual interface types that appear on virtual nodes. 'loopback' is an interface for failover addresses and should only appear if failover is configured.

Dell EMC Isilon Network Interface

Performance Inbound Throughput

float Inbound Throughput for this interface

Dell EMC Isilon Network Interface

Performance Outbound Throughput

float Outbound Throughput for this interface

Dell EMC Isilon Network Interface

Relationships Node Parents string List of parent Node resources

Dell EMC Isilon NFS Details Description string Specifies the user-defined string that is used to identify the export.

Dell EMC Isilon NFS Details Is Read Only string True if the export is set to read-only.

Dell EMC Isilon NFS Details Paths string The paths associated with the NFS export.

Dell EMC Isilon NFS Details Zone string Specifies the zone in which the export is valid.

Dell EMC Isilon NFS Disk Block Size integer Specifies the block size returned by the NFS statfs procedure.

Dell EMC Isilon NFS Relationships Access Zone Parents

string List of parent Access Zone resources

Dell EMC Isilon NFS Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon NFS Relationships Datastore parents string List of parent Datastores

Dell EMC Isilon Node CPU CPU Nice Average float Node average of nice CPU usage.

Dell EMC Isilon Node CPU CPU Nice Maximum float Node Maximum of nice CPU usage.

Dell EMC Isilon Node CPU CPU System Average

float Node average of system CPU usage.

Dell EMC Isilon Node CPU CPU System Maximum

float Node Maximum of system CPU usage.

Dell EMC Isilon Node CPU CPU Usage float The percentage CPU utilization.

Dell EMC Isilon Node CPU CPU User Average float Node average of user CPU usage.

Dell EMC Isilon Node CPU CPU User Maximum float Node Maximum of user CPU usage.

Management Pack for Dell EMC Isilon

VMware, Inc. 37

Page 38: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Node Details CPU Model string Manufacturer and model of this node's CPU.

Dell EMC Isilon Node Details Chassis string Name of this node's chassis.

Dell EMC Isilon Node Details Class string Class of this node (storage, accelerator, etc.).

Dell EMC Isilon Node Details Code Name string Code name of this node if applicable (Minnetonka, MiniHuron, Huron, Union, Tahoe, Superior, Unknown). If not supported: Unknown. If Logic to determine code name fails: Unknown. If PSI_Get fails: Unknown. PSI_Get can fail if PSI not initialized, or key does not exist.

Dell EMC Isilon Node Details Connected FTP Clients

integer Number of connected FTP clients

Dell EMC Isilon Node Details Connected HDFS Clients

integer Number of connected HDFS clients

Dell EMC Isilon Node Details Connected HTTP Clients

integer Number of connected HTTP clients

Dell EMC Isilon Node Details Connected NDMP Clients

integer Number of connected NDMP clients

Dell EMC Isilon Node Details Connected NFS Clients

integer Number of connected NFS clients

Dell EMC Isilon Node Details Connected SMB Clients

integer Number of connected SMB clients

Dell EMC Isilon Node Details Hardware Generation Name

string Isilon hardware generation name.

Dell EMC Isilon Node Details Is Read Only string The current read-only user mode status for the node. NOTE: If read-only mode is currently disallowed for this node, it will remain read/write until read-only mode is allowed again. This value only sets or clears any user-specified requests for read-only mode. If the node has been placed into read-only mode by the system, it will remain in read-only mode until the system conditions which triggered read-only mode have cleared.

Dell EMC Isilon Node Details Is Up string True if this node is still available to the cluster.

Dell EMC Isilon Node Details Model string Isilon node model identifier string (S200, X410, Infinity-H500, etc.).

Management Pack for Dell EMC Isilon

VMware, Inc. 38

Page 39: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Node Details Product string Isilon product name.

Dell EMC Isilon Node Details Release Version string OneFS release.

Dell EMC Isilon Node Details Serial Number string Serial number of this node.

Dell EMC Isilon Node Details Series string Series of this node (X, I, NL, etc.).

Dell EMC Isilon Node Details Storage Class string Storage class of this node (storage or diskless).

Dell EMC Isilon Node Details Tier integer Platform tier level of this node if applicable (1-4 are defined, 0 for unknown or not supported, -1 for error). If not supported: 0. If Logic to determine tier fails: 0 for unknown. If PSI_Get fails: -1 for error. PSI_Get can fail if PSI not initialized, or key does not exist.

Dell EMC Isilon Node Details Total Connected Clients

integer The total number of clients connected to FTP, HTTP, HDFS, NFS, and SMB

Dell EMC Isilon Node Disk Disk Busy Avg float Average disk busy

Dell EMC Isilon Node Disk Disk In float Traffic to disk.

Dell EMC Isilon Node Disk Disk Out Rate Avg float Average read throughput for all disks

Dell EMC Isilon Node Disk Disk Traffic Out float Traffic from disk.

Dell EMC Isilon Node Disk Disk Xfers Rate Avg float Average transfer rate for all disks

Dell EMC Isilon Node Disk Disk in Rate Avg float Average write throughput for all disks

Dell EMC Isilon Node Disk Drive Bay Count integer Number of drive bays (maximum disk count)

Dell EMC Isilon Node Disk IFS Percent Free float Percentage of free space on /ifs on the node

Dell EMC Isilon Node Disk IFS Percent Used float Percentage of used space on /ifs on the node

Dell EMC Isilon Node Disk IFS SSD Percent Free

float Percentage of free space on SSDs on /ifs on the node

Dell EMC Isilon Node Disk IFS SSD Percent Free

float Percentage of used space on SSDs on /ifs on the node

Dell EMC Isilon Node Disk IFS SSD Space Free integer Free space on SSDs on /ifs on the node

Dell EMC Isilon Node Disk IFS SSD Space Total integer Total size of SSD space in /ifs on the node

Management Pack for Dell EMC Isilon

VMware, Inc. 39

Page 40: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Node Disk IFS SSD Space Used integer Used space on SSDs on/ifs on the node

Dell EMC Isilon Node Disk IFS Space Free integer Free space on /ifs on the node

Dell EMC Isilon Node Disk IFS Space Total integer Total size of /ifs on the node

Dell EMC Isilon Node Disk IFS Space Used integer Used space on /ifs on the node

Dell EMC Isilon Node Memory Cached Memory integer Amount of physical system memory that are in use for cache.

Dell EMC Isilon Node Memory Free Memory integer Amount of physical system memory that are free.

Dell EMC Isilon Node Memory Memory Free Percent

float Percentage of free memory on the node

Dell EMC Isilon Node Memory Memory Used Percent

float Percentage of used memory on the node

Dell EMC Isilon Node Memory Total Ram integer Size of RAM.

Dell EMC Isilon Node Memory Used Memory integer Amount of physical system memory that are in use.

Dell EMC Isilon Node Network FTP Throughput float The total throughput for FTP operations.

Dell EMC Isilon Node Network HDFS Throughput float The total throughput for HDFS operations.

Dell EMC Isilon Node Network HTTP Throughput float The total throughput for HTTP operations.

Dell EMC Isilon Node Network NFS Throughput float The total throughput for NFS (NFS3 & NFS4) operations.

Dell EMC Isilon Node Network Network Traffic In float Incoming network traffic for all operations.

Dell EMC Isilon Node Network Network Traffic Out float Outgoing network traffic for all operations.

Dell EMC Isilon Node Network SMB Throughput float The total throughput for SMB (SMB1 & SMB2) operations.

Dell EMC Isilon Node Network Total Protocol Throughput

float The total throughput for all protocols listed.

Dell EMC Isilon Node Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon Node Relationships Network Interface Children

string List of child Network Interface resources

Dell EMC Isilon Quota Details Advisory Threshold integer Usage space at which notifications will be sent but writes will not be denied.

Management Pack for Dell EMC Isilon

VMware, Inc. 40

Page 41: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Quota Details Advisory Threshold Exceeded

string True if the advisory threshold has been hit.

Dell EMC Isilon Quota Details Hard Threshold integer Usage space at which further writes will be denied.

Dell EMC Isilon Quota Details Hard Threshold Exceeded

string True if the hard threshold has been hit.

Dell EMC Isilon Quota Details Include Snapshots string If true, quota governs snapshot data as well as head data.

Dell EMC Isilon Quota Details Is Enforced string True if the quota provides enforcement, otherwise a accounting quota.

Dell EMC Isilon Quota Details Is up to date string True if the accounting is accurate on the quota. If false, this quota is waiting on completion of a QuotaScan job.

Dell EMC Isilon Quota Details Logical Used Space integer Apparent space used by governed data.

Dell EMC Isilon Quota Details Path string The /ifs path governed.

Dell EMC Isilon Quota Details Persona ID string Specifies the serialized form of a persona, which can be 'UID:0', 'USER:name', 'GID:0', 'GROUP:wheel', or 'SID:S-1-1'.

Dell EMC Isilon Quota Details Soft Threshold integer Usage space at which notifications will be sent and soft grace time will be started.

Dell EMC Isilon Quota Details Soft Threshold Exceeded

string True if the soft threshold has been hit.

Dell EMC Isilon Quota Details Thresholds Include Overhead

string If true, thresholds apply to data plus filesystem overhead required to store the data (i.e. 'physical' usage).

Dell EMC Isilon Quota Details Type string The type of quota.

Dell EMC Isilon Quota Details Usage Percent float Percent of quota used based on hard threshold.

Dell EMC Isilon Quota Disk Physical Used Space integer Space used for governed data and filesystem overhead.

Dell EMC Isilon Quota Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon SMB Details Access Zone ID integer Numeric ID of the access zone which contains this SMB share.

Dell EMC Isilon SMB Details Description string Description for this SMB share.

Dell EMC Isilon SMB Details Name string Share name.

Management Pack for Dell EMC Isilon

VMware, Inc. 41

Page 42: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon SMB Details Path string Path of share within /ifs.

Dell EMC Isilon SMB Relationships Access Zone Parents

string List of parent Access Zone resources

Dell EMC Isilon SMB Relationships Cluster Parents string List of parent Cluster resources

Dell EMC Isilon Storage Pool

Details Balanced string Whether or not the pool usage is currently balanced.

Dell EMC Isilon Storage Pool

Details Can Disable L3 string Indicates if disabling L3 is possible.

Dell EMC Isilon Storage Pool

Details Can Enable L3 string Indicates if enabling L3 is possible. L3 cannot be enabled if there are unprovisioned drives.

Dell EMC Isilon Storage Pool

Details L3 Status string 'storage' if the 'l3' option is disabled. If the l3 option is enabled, 'migrating' if any SSDs in this node pool have not yet been migrated to L3. If all SSDs have been migrated, 'l3'.

Dell EMC Isilon Storage Pool

Details LNNs string The nodes that are part of this pool.

Dell EMC Isilon Storage Pool

Details Manually Managed string Whether or not the node pool is manually managed.

Dell EMC Isilon Storage Pool

Details Name string The pool name.

Dell EMC Isilon Storage Pool

Details Type string The pool type.

Dell EMC Isilon Storage Pool

Disk Available HDD Space

integer Available free space remaining in the pool on HDD drives when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Available SSD integer Available free space remaining in the pool on SSD drives when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Free HDD Space integer Free space remaining in the pool on HDD drives.

Dell EMC Isilon Storage Pool

Disk Free SSD Space integer Free space remaining in the pool on SSD drives.

Dell EMC Isilon Storage Pool

Disk Free Space integer Free space remaining in the pool.

Dell EMC Isilon Storage Pool

Disk Total Available Space

integer Available free space remaining in the pool when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Total HDD Space integer Total space in the pool on HDD drives.

Management Pack for Dell EMC Isilon

VMware, Inc. 42

Page 43: Management Pack for Dell EMC Isilon - Management Packs for

Resource Kind Resource Group Resource AttributeAttribute Type Attribute Description

Dell EMC Isilon Storage Pool

Disk Total SSD Space integer Total space in the pool on SSD drives.

Dell EMC Isilon Storage Pool

Disk Total Space integer Total space in the pool.

Dell EMC Isilon Storage Pool

Disk Total Used Space integer Used space in the pool.

Dell EMC Isilon Storage Pool

Disk Total Used Space Ratio

float Percentage of usable space in the pool which is used.

Dell EMC Isilon Storage Pool

Disk Usable HDD Space integer Total space in the pool on HDD drives when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Usable SSD integer Total space in the pool on SSD drives when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Usable Space integer Total space in the pool drives when virtual hot spare is taken into account.

Dell EMC Isilon Storage Pool

Disk Used HDD Ratio float Percentage of usable space on HDD drives in the pool which is used.

Dell EMC Isilon Storage Pool

Disk Used HDD Space integer Used space in the pool on HDD drives.

Dell EMC Isilon Storage Pool

Disk Used SSD Ratio float Percentage of usable space on SSD drives in the pool which is used.

Dell EMC Isilon Storage Pool

Disk Used SSD Space integer Used space in the pool on SSD drives.

Dell EMC Isilon Storage Pool

Disk Virtual Hot Spare Space

integer Space available on the virtual hot spare.

Dell EMC Isilon Storage Pool

Relationships Cluster Parents string List of parent Cluster resources

Management Pack for Dell EMC Isilon

VMware, Inc. 43