    SFX Dial-Up Program

    SETX

    PROGRAM EXPLANATIONS

  • 8/10/2019 manual estacion total sokkia

    2/27

    i

    Introduct ion

    Thank you for purchasing SFX Dial-Up Software for SETX.

    Before using the instrument, please read this manual carefully.

    Some of the diagrams and screen displays shown in this manual are simplified for easier understanding.

    Sokkia continually conducts research and development in order to make its products easier to use and enhancetheir precision. The specifications and general appearance of the instrument may be altered without prior notifi-

    cation. This manual is protected by copyright and all rights are reserved by Sokkia Co., Ltd.

    Sokkia Co., Ltd. will not be liable to you for any profit or loss resulting from the use of this manual.

    Except as permitted by Copyright law, this manual may not be copied, and no part of this manual may be repro-duced in any form or by any means.

    This manual may not be modified, adapted or otherwise used for the production of derivative works.

    Manuals 1, and 3 below are electronic manuals delivered on a CD-ROM in PDF format ( ). Adobe Reader is

    necessary in order to view these documents. The latest version of Acrobat Reader can be downloaded from the

    Adobe homepage.

    How to read this manual

    The SETX comes equipped with 3 manuals for operation information:

    1. SFX Dial-Up Program Explanations (SETX) (this manual) : Explains how to send and receive data

    using the SFX function

    2. Operators Manual: Explains basic operation and functions of the total station.

    3. SDR Software Reference Manual (SETX) : explains advanced measurement operations using the

    SETX in Program mode, and methods for managing measured data.

    For switching between modes on the SETX, see "1.2 Mode Structure".

    For information on key operation and using the SETX screen, see Chapter 5. BASIC OPERATION of the Oper-ators Manual for your total station.

    Symbols

    The following conventions are used in this manual.

    [Softkey] Indicates softkeys on the display.

    {KEY} Indicates a keyboard key that causes an immediate action.

    Examples: {1}, {F1}, {ESC}, {Y}, {N}. If you must press multiple

    keys to initiate an action, the combination will be shown with a

    plus sign between the keystrokes; for example, {FUNC CTRL}+

    {}.

    Contents Indicates the content in each window.

    Indicates precautions and important items, which should be readbefore operation.

    Indicates the manual or chapter title to refer to for additional informa-tion.

    Indicates supplementary explanations.

    Indicates an explanation for a particular term or operation.

    Indicates screen titles.

  • 8/10/2019 manual estacion total sokkia

    3/27

  • 8/10/2019 manual estacion total sokkia

    4/27

    Contents

    iii

    1. Product Outline......................................................................................................1

    1.1 SFX Functions .................................................................................................................... 1

    1.2 Mode Structure ................................................................................................................... 2

    2. Connecting All Equipment ..................................................................................... 32.1 Necessary Items................................................................................................................. 3

    2.2 Connecting All Equipment .................................................................................................. 4

    3. Dial-Up Connection................................................................................................5

    3.1 Booting Up and Quitting ..................................................................................................... 5

    3.2 Setting Communication Settings ........................................................................................ 5

    3.3 Registering an E-mail Address ........................................................................................... 8

    4. Sending and Receiving E-mail...............................................................................9

    4.1 Sending E-mail (Coordinate Data/JOB Data) ..................................................................... 94.2 Receiving E-mail with the Surveying Instrument (Coordinate Data)................................. 11

    4.3 FTP Server Connection (Coordinate Data/JOB Data)...................................................... 12

    4.4 Sending E-mail to the Surveying Instrument .................................................................... 17

    4.5 Receiving E-mail from the Surveying Instrument ............................................................. 18

    5. Error Messages ...................................................................................................19

    6. Troubleshooting...................................................................................................21

  • 8/10/2019 manual estacion total sokkia

    5/27

    1

    1. PRODUCTOUTLINE

    1.1 SFX Functions

    The SFX Dial-up program allows the operator to connect the total station to a cellular phone in order to

    exchange data by connecting to an FTP server or to transfer data as email attachments between the

    surveying instrument and a computer, while in the field. Coordinate data transferred to the total station

    in this way can be added into JOB data in Program mode.

    All data needed for surveying can be exchanged at the worksite.

    As data can be sent to a computer via e-mail, there is no need to return to the office to hand

    over surveyed data.

    All data needed for surveying can be transferred via e-mail so there is no need to waste time

    downloading before heading for the worksite.

    Surveyed data can be sent promptly back to the office for processing allowing the operator to

    get feedback on the quality of the surveyed data quickly and without having to leave the

    worksite. The operator can respond to deficiencies in the data much faster as a result.

    Coordinate data can be exchanged between total stations using the SFX function allowing

    greater flexibility when allocating tasks in the field.

    A program designed to allow Internet provider information, e-mail address, and FTP server

    information to be set on an operators PC is available free of charge. For details, ask your Sokkia

    agent.

    Ex.1

    Ex. 2

    Ex. 3

    Ex. 4

    Total station 1

    Total station 2

    Coordinate data

    Coordinate data

    Coordinate data

    JOB data

    JOB data

    JOB data Internet

    Computer (at office)

  • 8/10/2019 manual estacion total sokkia

    6/27

    1. PRODUCTOUTLINE

    2

    1.2 Mode Structure

    Switching between modes is not possible during distance measurement.

    TLT-OFS

    TLT-OFS

    EDM TILT

    MENU OFFSET

    MLM

    EDM TILT

    MENU OFFSET

    MLM

    5.4 SETTINGS Mode

    Basic modeOperators Manual

    Status screen

    [Version][OK] {ESC}

    Meas Mode (Navigable with tabs)

    Menu mode

    Configuration Mode

    {SETTINGS}

    Settings mode

    {PROGRAM}Program mode

    Operators Manual

    { SETTINGS }SDR Software

    5.2 Display

    Operators Manual

    Functions

    Reference Manual

    Operators Manual

    Operators Manual

    Chapters 14-19

    Chapter 20

    (SETX)

  • 8/10/2019 manual estacion total sokkia

    7/27

    3

    2. CONNECTINGALLEQUIPMENT

    2.1 Necessary Items

    The following items are necessary in order to use the SFX dial-up program with the surveying instrument.

    Internet provider service

    An Internet provider service is necessary in order to be able to send and receive e-mail. Theaccess details supplied by your provider are input when configuring the e-mail settings on

    the surveying instrument.

    When using Bluetoothtechnology

    Bluetoothequipped cellular phone

    When using a modem

    Cellular phone with built-in modem

    Interface cableDedicated optional accessory for connecting the surveying instrument and your cellular phone.

    Sokkia cannot guarantee that all cellular phones with built-in modems are compatible with

    the SFX system. Therefore, to check the compatibility of your cellular phone, please consult

    your Sokkia agent.

  • 8/10/2019 manual estacion total sokkia

    8/27

    2. CONNECTINGALLEQUIPMENT

    4

    2.2 Connecting All Equipment

    Connect all equipment as shown below. Make sure that the power of both the surveying instrument and

    the cellular phone is off before connecting.

    When using Bluetoothtechnology

    When using a modem

    For connecting the cellular phone to the dedicated interface cable, see the operator's manual foryour cellular phone/interface cable.

    Bluetoothequippedcellular phone

    Combined communications and

    Interface cable for yourcellular phone

    EDC120/EDC121

    Modem

    Publictelephone

    Fixed-linetelephone

    Serial

    reverse

    adapter

    power supply connector

  • 8/10/2019 manual estacion total sokkia

    9/27

    5

    3. DIAL-UPCONNECTION

    3.1 Booting Up and Quitting

    PROCEDURE Booting up

    1. Select Dial-up from the Functionsmenu.

    The following cannot be operated while dial-up

    is in progress.

    {SETTINGS}

    Status bar

    Power OFF

    PROCEDURE Quitting

    1. Press{ESC} repeatedly to return to Program mode.

    3.2 Setting Communication Settings

    Internet provider information must be registered on the surveying instrument in order to use the e-mail

    function.

    Registering Internet provider information Communication settings

    Saving settings All settings are saved when the operator quits the program. SFX will function according to these

    new and modified settings once the program has been shut down then rebooted.

  • 8/10/2019 manual estacion total sokkia

    10/27

    3. DIAL-UPCONNECTION

    6

    PROCEDURE Registering Internet provider information

    1. Press [Config] in / to display

    2. Set the following items. The information marked with *

    is supplied by your Internet provider. For any inquiries

    regarding this information, ask your Internet provider.

    Phone 1 to 3*Input the telephone number for the access point. Up to 3 telephone numbers may be registered.

    Spaces and hyphens may be omitted.

    PPP login*Input the ISP connection login name.

    PPP password*Input the ISP connection password.

    IP address*Input the IP address when allocated. When using an address automatically assigned by the server

    input "0.0.0.0.".

    DNS1, DNS2*Input the primary (DNS1) and secondary (DNS2) addresses for the DNS server.

    POP server*Input the POP server name using no more than 64 characters.

    SMTP server*Input the SMTPserver name using no more than 64 characters.

    Mail address*Input the e-mail address allocated to that instrument.

    POP login*Input the login name for the POP server using no more than 64 characters.

  • 8/10/2019 manual estacion total sokkia

    11/27

    3. DIAL-UPCONNECTION

    7

    POP password*Input the POP server password using no more than 64 characters.

    TimeoutSet the timeout, in seconds, for the connection to the server.

    Leave on serverCheck the check box to leave received e-mail on the server. To delete received e-mail, clear the box.

    POP before SMTPCheck the box to activate user authentication.

    3. Press [OK] on page 3 to finish settings.

    PROCEDURE Communication Settings

    1. Press [COM] in a Config screen to display .

    2. Select a device in Device, then set communication

    settings.

    A Bluetooth device that has already been registeredcan also be selected in Device.

    Operators Manual 11.1 Wireless Communica-tion using Bluetooth Technology

    Check PC COM when connecting to a computerusing Sokkias configuration software in order to

    register provider and mail address information.

    3. Press [OK] on page 3 to finish settings.

  • 8/10/2019 manual estacion total sokkia

    12/27

    3. DIAL-UPCONNECTION

    8

    3.3 Registering an E-mail Address

    Register the outgoing e-mail address (no more than 64 characters) beforehand. Up to 3 e-mail

    addresses can be registered.

    Saving settings

    All settings are saved when the operator quits the program. SFX will function according to thesenew and modified settings once the program has been shut down then rebooted.

    PROCEDURE

    1. Press [Address]in or to display .

    All the currently registered e-mail addresses are

    displayed.

    2. Input the e-mail address and press[OK] on page 3 to

    finish settings.

    Press[ISP]on page 2 to continue registering Internet provider information. Press[COM]on page 2 to continue communication settings.

    Press [SendMail] on page 1 to send an e-mail.

    Press [RecvMail]on page 1 to receive e-mail.

  • 8/10/2019 manual estacion total sokkia

    13/27

    9

    4. SENDINGANDRECEIVINGE-MAIL

    4.1 Sending E-mail (Coordinate Data/JOB Data)

    Coordinate data and JOB data can be sent from the surveying instrument as e-mail attachments.

    When using Bluetoothwireless technology for SFX communication, complete Bluetoothsettings before

    starting transmission.

    Operators Manual 11. CONNECTING TO EXTERNAL DEVICES

    PROCEDURE

    1. Press [SendMail]in page 1 of a Config screen to dis-

    play .

    2. Select a data format from Format.

    3. Highlight the JOB to be sent from JOB and press

    [YES] to confirm selection. Press [NO] to cancel

    selection.

    Multiple JOBs can be selected.

    Press [ALL]to select all JOBs.

    Press [Create] when JOB selection is complete.

    Do not select multiple JOBs with the same name.

  • 8/10/2019 manual estacion total sokkia

    14/27

    4. SENDINGANDRECEIVINGE-MAIL

    10

    4. Highlight a destination address in Addressand press

    [YES] to confirm selection. Press [NO] to cancel

    selection.

    Multiple destination addresses can be selected.

    Press [ALL]to select all addresses.

    Press [NEXT] when address selection is complete.

    5. Select a device in Device.

    6. Select an access point telephone number from

    Phone.

    7. Press [Connect]to start transmission. PPP dialing...

    is displayed.

  • 8/10/2019 manual estacion total sokkia

    15/27

    4. SENDINGANDRECEIVINGE-MAIL

    11

    8. The name of the JOB, data format, and the number of

    records currently being transmitted is displayed on the

    screen during transmission.

    Multiple JOBs are sent one JOB per e-mail.

    When all selected JOBs have been successfully

    transmitted, SFX disconnects from the Internet and

    returns to the screen in step 1. The cellular phone dis-

    play returns to the standby screen.

    Pressing [Disc] during transmission will forcibly cut

    the connection and stop transmission. The transmis-

    sion of the JOB being transmitted at that point may not

    be successfully completed as a result.

    4.2 Receiving E-mail with the Surveying Instrument (Coordinate

    Data)

    After reading in a coordinate file sent as an e-mail attachment in SDR format, the surveying instrumentrecords it as coordinate data at the end of the currently selected JOB.

    PROCEDURE

    1. Press [RecvMail]in or page 1 of

    a Config screen to display .

    2. Select a device in Device and an access point tele-

    phone number from Phone.

    "3.2 Setting Communication Settings"

    3. Press [Connect]to start reception. PPP dialing... is

    displayed.

  • 8/10/2019 manual estacion total sokkia

    16/27

    4. SENDINGANDRECEIVINGE-MAIL

    12

    When a connection has been established the following

    message is displayed and reception starts.

    4. SFX will automatically search the server for all e-mail

    for the surveying instrument. A list of all incoming e-

    mail with csv/sdr data file attachments and the

    respective data type will be listed on the screen.

    5. Highlight the desired coordinate data in Maillist and

    press [YES]to confirm selection. Press[NO] to cancel

    selection.

    Multiple sets of coordinate data can be selected.

    Press [ALL]to select all JOBs.

    SDR data and CSV data cannot be read in at the

    same time. Make sure that selected files are either

    all SDR or all CSV data.

    Press [Recv] when data selection is complete.

    The number of records currently being read in is dis-

    played on the screen as the e-mail containing the

    attached data is being received.

    Pressing[Disc] during transmission will forcibly cut

    the connection and stop transmission. All the databeing received at that point will be lost.

    When all selected data have been successfully

    transmitted, SFX disconnects from the Internet, the

    cellular phone display returns to the standby screen

    and data is recorded. Once data has been recorded,

    the display returns to the screen in step 1.

  • 8/10/2019 manual estacion total sokkia

    17/27

    4. SENDINGANDRECEIVINGE-MAIL

    13

    4.3 FTP Server Connection (Coordinate Data/JOB Data)

    The surveying instrument accesses an office or PC FTP server in order to write or read in JOB data or

    coordinate data.

    The file to be sent is converted to SDR format and written to the server as "Job Name

    .sdr". When a file with the same name already exists on the server, a letter (from a to z) is appended to the

    end of the most recent file name (JOB name).

    The surveying instrument can only read in files with the file extensions ".sdr" and .csv.

    From the files with the extension ".sdr",only coordinate data is read in. The surveying instrument

    records it as coordinate data at the end of the currently selected JOB.

    PROCEDURE Writing (sending) a file

    1. Press [FTP con] in to display

    .

    2. Select the relevant server in FTPserver.

    3. Press [Connect] to start reception. FTP connect-ing... is displayed.

    When a connection has been established the followingscreen is displayed.

    Press [SendFile].

  • 8/10/2019 manual estacion total sokkia

    18/27

    4. SENDINGANDRECEIVINGE-MAIL

    14

    4. Select a data format from Format.

    5. Highlight the JOB to be sent from JOB and press

    [YES] to confirm selection. Press [NO] to cancel

    selection.

    Multiple JOBs can be selected.

    Press [ALL]to select all JOBs.

    Press [Send] when JOB selection is complete to start

    transmission.

    Do not select multiple JOBs with the same name.

    The name of the JOB currently being transmitted and

    the number of records (JOB data records, coordinate

    points) successfully transmitted are displayed on the

    screen during transmission.

    Pressing[Disc]during transmission will forcibly cutthe connection and stop transmission. All the data

    being received at that point will be lost.

    When all selected data have been successfully

    transmitted, data is recorded and SFX returns to the

    second screen in step 3. Further files can now be sent

    or read in.

  • 8/10/2019 manual estacion total sokkia

    19/27

    4. SENDINGANDRECEIVINGE-MAIL

    15

    PROCEDURE Reading in (receiving) a file

    1. Press [FTP con] in to display

    .

    2. Select the relevant server in FTPserver.

    3. Press [Connect] to start reception. FTP connect-

    ing... is displayed.

    When a connection has been established the following

    screen is displayed.

    Press [RecvFile].

    4. SFX will automatically search the server for all data

    files for the surveying instrument. A list of all csv/sdr

    data files and the respective data type will be listed on

    the screen.

  • 8/10/2019 manual estacion total sokkia

    20/27

    4. SENDINGANDRECEIVINGE-MAIL

    16

    5. Highlight the desired file in File and press [YES] to

    confirm selection. Press[NO] to cancel selection.

    Multiple sets of data can be selected.

    Press[ALL] to select all JOBs.

    SDR data and CSV data cannot be read in at the

    same time. Make sure that selected files are either

    all SDR or all CSV data.

    Press [Recv] whendata selection is complete to start

    transmission.

    The name of the file currently being read in and the

    number of coordinate points in the current file are dis-

    played.

    When all selected files have been successfullyread in, data is recorded and SFX returns to the sec-

    ond screen in step 3. Further files can now be read in

    or sent.

    Pressing[Disc] during transmission will forcibly cut

    the connection and stop transmission. All the data

    being received at that point will be lost.

  • 8/10/2019 manual estacion total sokkia

    21/27

    4. SENDINGANDRECEIVINGE-MAIL

    17

    4.4 Sending E-mail to the Surveying Instrument

    E-mail is sent from the computer to the surveying instrument using standard e-mail programs.

    The method for sending an e-mail from the computer to the surveying instrument is the same as that for

    sending a normal e-mail.

    Compose an e-mail addressed to the address assigned to the surveying instrument.

    So that the surveying instrument can distinguish which e-mails to receive, input "SDR>"or CSV>followed by a user-specified title in the subject line.

    Text input in the body of the message will not be displayed on the surveying instrument.

    Even if multiple files are attached to a single e-mail, the surveying instrument can only receive the first

    attachment.

    SDR-format coordinate data appended as an attachment. The file extension for attachment files should

    be ".sdr".

    The surveying instrument selects incoming e-mail with a subject line starting with SDR>or CSV> and

    displays them in a list.

    For more details on sending and receiving e-mails, see the operators manual for your e-mailprogram.

  • 8/10/2019 manual estacion total sokkia

    22/27

    4. SENDINGANDRECEIVINGE-MAIL

    18

    4.5 Receiving E-mail from the Surveying Instrument

    The method for receiving an e-mail from the surveying instrument on a computer is the same as that for

    receiving a normal e-mail.

    The subject line of the e-mail sent from the surveying instrument will be in the format "SDR>JOB Name."

    or CSV>JOB Name., and the file name of the attached e-mail in the format, "JOB name.sdr" or "JOB

    name.csv".

    Microsoft Outlook Express 6.0 Example

    For more details on sending and receiving e-mails, see the operators manual for your e-mailprogram.

  • 8/10/2019 manual estacion total sokkia

    23/27

    19

    5. ERRORMESSAGES

    The following is a list of the error messages displayed by the surveying instrument and the meaning of

    each message. If the same error message is repeated or if any message not shown below appears, the

    instrument has malfunctioned. Contact your Sokkia agent.

    Message Cause Solution

    Bluetooth Parameter

    Error

    A Bluetooth connection

    could not be estab-

    lished.

    Check settings.

    BluetoothTimeout A Bluetooth connection

    could not be estab-

    lished.

    Check that the Bluetooth device(s) is switched

    on and the settings are correct.

    Connection aborted A Bluetooth connection

    could not be estab-

    lished.

    Check that the Bluetooth device(s) is switched

    on and the settings are correct.

    CSV Import Err (DLL) An error occurred while

    converting the attached

    file.

    Check the format of the attached file.

    File Read Err An error occurred while

    reading in a file from the

    FTP server.

    Try again. If the problem persists, contact the

    administrator of your FTP server.

    File ReadOpen Err

    File WriteOpen Err

    An error occurred while

    trying to open a file on

    the FTP server.

    Try again. If the problem persists, contact the

    administrator of your FTP server.

    File Write Err An error occurred while

    writing a file to the FTP

    server.

    Try again. If the problem persists, contact the

    administrator of your FTP server.

    FTP Change Dir Err An error occurred while

    trying to move a direc-

    tory on the FTP server.

    Try again. If the problem persists, contact the

    administrator of your FTP server.

    FTP Connect Err An error occurred while

    connecting to the FTP

    server.

    Check the FTP server settings and try again. If

    the problem persists, contact the administrator of

    your FTP server.

    FTP Search Err An error occurred while

    obtaining a list from the

    FTP server.

    Try again. If the problem persists, contact the

    administrator of your FTP server.

    Invalid Mail Address No sender e-mail

    address entered.

    Register an e-mail address in .

    Invalid POP server

    Login name or pass-

    word

    No POP server login

    name/password

    entered.

    Register the POP server login name and pass-

    word in .

    Invalid POP server

    name

    No POP server name

    entered.

    Register the POP server IP address in .

    Invalid SMTP server

    name

    No SMTP server name

    entered.

    Register the SMTP server name in .

    JobList Read Err(DLL) An error occurred whilesearching the server for

    e-mail for the SETX.

    Try receiving the e-mail again.

  • 8/10/2019 manual estacion total sokkia

    24/27

    5. Error Messages

    20

    Mail Delete Err An error occurred while

    trying to delete received

    e-mail.

    Try receiving and deleting the same e-mail

    again. Alternatively, try to delete using Telnet.

    No mail available There is no file attached

    to the selected e-mail.

    Attach a file and send the e-mail again.

    POP Connect Err Connection to the POP

    server failed.

    Check the settings in . If a

    connection still cannot be established try again

    later.

    POP Connect Err Connection to the POP

    server failed.

    There was an error in the server response or

    login failed due to a mistake in POP server set-

    tings. Check parameters and try again.

    PPP Start Err A dial-up connection

    could not be estab-lished using the dis-

    played phone number.

    Check that the phone and cable are connected

    correctly. If a connection still cannot be estab-lished try again later.

    SDR Import Err (DLL) An error occurred while

    converting the attached

    file.

    Check the format of the attached file.

    SendFile Rename Err There is a problem with

    the file to be sent.

    Files with the same JOB name cannot be sent

    simultaneously. Files with the same JOB name

    should be sent separately.

    SMTP Connect Err User authentication for

    the SMTP server is

    required.

    Check POP before SMTP in .

    Message Cause Solution

  • 8/10/2019 manual estacion total sokkia

    25/27

    21

    6. TROUBLESHOOTING

    What follows is a list of foreseeable problems the operator may encounter while using SFX. Under each

    heading is a description of items to check and possible solutions. When a problem not listed here occurs

    or the suggested solution is ineffective, contact your Sokkia agent.

    Loss of power during communication

    A depleted battery cannot be replaced during communication. Check the remaining battery power

    before starting communication.If the battery power is completely depleted during communication, the instrument will switch off but

    will still be connected to the Internet. Disconnect the Internet connection before replacing the battery.

    It is possible that e-mail has not been successfully transferred. If necessary transfer the e-mail again.

    Failed connection

    Cellular phone reception

    Whenever possible, perform communication in areas where there is good cellular phone reception.

    When performing communication indoors radio field intensity is weak and the connection is unstable.

    For the service area of your cellular phone, contact your telecoms operator. For other details, see the

    operators manual for your cellular phone.

    File size

    Reduce the size of the file being sent/received by dividing into multiple sections and sending/

    receiving attached to multiple e-mails. File sizes causing delays in transmission will vary depending

    on communication conditions and devices being used. As the maximum file size that can be

    successfully transmitted will vary depending on these conditions file size should be set accordingly

    (the recommended maximum range is from 2000 to 3000 records).

    If the size of a file received from the FTP server is large, writing to a JOB will take a long time, possibly

    resulting in the server timing out before completion.

    E-mail program settings

    Certain e-mail program settings may result in communication failure. Please consult the settings

    screen shown below. If the "No mail available" error message is displayed even when a file has been

    attached, type a message in the body section of the e-mail.

    (1) Using Microsoft Outlook Express 6Select [Tools] - [Options] to open the following window.

  • 8/10/2019 manual estacion total sokkia

    26/27

    6. TROUBLESHOOTING

    22

    Set "Mail Sending Format" in the Sendtab to "Plain Text".

    Press Plain Text Settingsto open the next window.

    Set "message format" to "MIME".

    (2) When using Mozilla 1.7.5

    Select [Options] - [Format] - [Plain Text Only]

  • 8/10/2019 manual estacion total sokkia

    27/27

    1st ed. 01-0710 2007 SOKKIA CO., LTD.

    JAPAN