    ABB

    Contents

    1SKC000013C0201

    1/89Automation Technologies

    MMS

    Manual Motor Starters

    Technical Data................................................................................................................... 1/90

    MS 116

    Ordering Details ........................................................................................................... 1/92

    Accessories .................................................................................................................. 1/93

    MS 325

    Ordering Details ........................................................................................................... 1/95

    Accessories .................................................................................................................. 1/96

    Wiring Digrams.................................................................................................................. 1/98

    Dimensions Details

    MS 116 ......................................................................................................................... 1/99

    MS 325 ......................................................................................................................... 1/100

    Accessories .................................................................................................................. 1/101

  • 7/29/2019 Manual Motor Starters

    3/141SKC000013C0201

    1/90 Automation Technologies

    Manual Motor Starters

    Specifications MS 116 MS 325

    Standards: The devices comply with the major international,

    European and national regulations IEC 60../ EN 60..

    Disconnector characteristics (to IEC/ EN 60947- 1)

    Mechanical service life in operations

    Permissible ambient temperature

    - open C

    - encapsulated (in protective housing) C- Storage temperature C

    Temperature compensation

    Mounting position

    Permissible altitude m

    Permissible resistance to vibrations (IEC 68- 2- 6)2)

    Permissible resistance to shocks (IEC 68- 2- 27)

    Mounting (mounting hardware not included in scope of delivery)

    - Screw fixing

    - Quick fastening on top hat railto to EN 50022

    Electrical connection of the main conductors (main circuits)

    Type

    Screw

    Single- core 1 x mm2

    2 x mm2

    Stranded 1 x mm2

    2 x mm2

    Flexible 1 x mm2

    2 x mm2

    of the auxiliary conductors (auxiliary circuits)

    Type

    Screw

    Single- core 1 x mm2

    2 x mm2

    Flexible 1 x mm2

    2 x mm2

    Rated insulation voltage U i

    to EN 60947 V AC

    to CSA / U L / NEMA V AC

    Rated operating voltage U e up to V

    Rated impulse strength U imp kVRated continuous thermal current I th A

    Rated frequency7) Hz

    Rated current ranges Ie A

    (number of ranges)

    DC rated operating voltage in the case of series connection

    of 3 main circuits

    (see wiring diagram, Page.....) DC 1, 60 V A

    DC 3, 60 V A

    DC 5, 60 V A

    Short circuit capacity for DC- rating

    947-1, 947-2

    947-4-1, 947-5-1

    Yes

    100.000

    - 20... + 55/701)

    On request- 50... + 80

    with

    as illustrated6)

    3000

    10 - 150 Hz amplitude 5g

    sinusoidal shock 25g (11 ms)

    See accessories

    35 mm

    Screw terminal

    Pozidrive size 2

    1... 4

    1... 43)

    1... 43)

    1... 4

    0.75... 2.5

    0.75... 2.5

    Screw terminal

    Pozidrive size 2

    1... 2.55)

    1... 2.55)

    0.75... 2.5

    0.75... 2.5

    690

    600

    690 AC / 440 DC

    616

    50 / 60

    -

    -

    On request

    On request

    On request

    On request

    947-1, 947-2

    947-4-1, 947-5-1

    Yes

    100.000

    - 22... + 551)

    - 25... + 40- 50... + 80

    with

    Any

    3000

    10 - 150 Hz amplitude 5g

    sinusoidal shock 15g (11 ms)

    See accessories

    35 mm

    Box terminal

    Pozidrive size 2

    1... 10

    1... 4

    1... 10-

    1... 6

    -

    Screw terminal4)

    Pozidrive size 2

    0.5... 2.5

    0.5... 2.5

    0.5... 2.5

    0.5... 2.5

    690

    600

    690 AC / 440 DC

    - / 625

    50 / 60

    0.1... 25

    (14)

    25

    25

    25

    On request

    1) Operating conditions up to 70 C on request

    2) G- values refer to the mounting position subject to the highest shock sensitivity

    3) Also applies to auxiliary switches HKF1 and undervoltage release UA14) For auxiliary switch HKF.. Pozidrive 2

    5) Applies to auxiliary switches HK1 and SK1

    6) Other mounting posistions on request

    7) Correction factors for other frequencies on request

    Manual Motor StartersTechnical Data

  • 7/29/2019 Manual Motor Starters

    4/141SKC000013C0201

    1/91Automation Technologies

    MMS

    Auxiliary circuits

    Specifications MS 116 MS 325

    Load rating of the auxiliary circuits Minimum load at:

    24 V DC mA

    12 V DC mA

    Rated operating current Ie:

    at AC 15 to 24 V AC A230 V AC A

    400 V AC A

    at DC 13 to 24 V DC A

    60 V DC A

    110 V DC A

    220 V DC A

    440 V DC A

    Short- circuit protection back up fuse gL A

    aM A

    5 mA at 17 VDC

    -

    64

    3

    2

    -

    0.5

    0.25

    0.1

    On request

    5

    10

    2.52

    1

    2.5

    2.5

    0.6

    0.25

    -

    10

    6

    ReleaseSpecifications MS 116 MS 325

    Device for phase failure protection

    Electromagnetic trips

    Response value set ex-works

    Undervoltage release

    Pick- up value % of Uc

    Drop- out value % of Uc

    Power consumption Pick up VA

    Hold VA

    Open circuit shunt release

    Pick- up value % of Uc

    Relative duty % ED

    consumption Pick up VA

    Hold VA

    With

    9.6... 14.4 x In

    85

    35... 75

    On request

    On request

    -

    -

    -

    -

    -

    7.5... 12 In1)

    9... 14 In2)

    10... 15 In3)

    12.5... 17 In4)

    85

    35... 75

    0.9

    0.9

    85

    -

    110 - 240 V: 13 - 165)

    -

    1) Current ranges 0.16 to 0.63 A2) Current ranges 1 to 2.5 A

    3) Current ranges 4 to 6.3 A

    4) Current ranges 9 to 25 A

    5) 24 - 60 V: 14.4 - 90 VA

    Manual Motor StartersTechnical Data (continued)

  • 7/29/2019 Manual Motor Starters

    5/141SKC000013C0201

    1/92 Automation Technologies

    Manual Motor StartersMS 116

    Ordering Details

    Open design, enclosure IP 20

    resistant to changeable climates.

    Quick fastening on mounting rails DIN EN 50 022

    35 mm without auxiliary switch.

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    MS 116 with thermal and electromagnetic trips, short-circuit proof up to 50 kA

    0.10... 0.16

    0.16... 0.25

    0.25... 0.40

    0.40... 0.63

    0.63... 1.00

    1.00... 1.60

    1.60... 2.50

    2.50... 4.00

    4.00... 6.30

    6.30... 10.00

    8.00... 12.00

    10.00...16.00

    MS 116 - 0.16

    MS 116 - 0.25

    MS 116 - 0.4

    MS 116 - 0.63

    MS 116 - 1.0

    MS 116 - 1.6

    MS 116 - 2.5

    MS 116 - 4

    MS 116 - 6.3

    MS 116 - 10.0

    MS 116 - 12.0

    MS 116 - 16.0

    1SAM 250 000 R 1001

    1SAM 250 000 R 1002

    1SAM 250 000 R 1003

    1SAM 250 000 R 1004

    1SAM 250 000 R 1005

    1SAM 250 000 R 1006

    1SAM 250 000 R 1007

    1SAM 250 000 R 1008

    1SAM 250 000 R 1009

    1SAM 250 000 R 1010

    1SAM 250 000 R 1012

    1SAM 250 000 R 1011

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    0.268

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    AccessoriesAuxillary switches, for front panel installation*

    1 NO + 1 NC HKF1-11 1SAM 201 901 R 1001 10

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Auxillary switches, lateral attachment at right

    1 NO + 1 NC

    2 NO

    2 NC

    HK1-11

    HK1-20

    HK1-02

    1SAM 201 902 R 1001

    1SAM 201 902 R 1002

    1SAM 201 902 R 1003

    10

    10

    10

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Signal contact for general tripped signal, lateral attachment at right

    1 NO + 1 NC

    2 NO

    2 NC

    SK1-11

    SK1-20

    SK1-02

    1SAM 201 903 R 1001

    1SAM 201 903 R 1002

    1SAM 201 903 R 1003

    10

    10

    10

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Undervoltage release, lateral attachment at left

    24 V AC

    48 V AC

    60 V AC

    120 V AC

    230 V AC

    400 V AC

    415 V AC

    UA1-24

    UA1-48

    UA1-60

    UA1-120

    UA1-230

    UA1-400

    UA1-415

    1SAM 201 904 R 1001

    1SAM 201 904 R 1002

    1SAM 201 904 R 1003

    1SAM 201 904 R 1004

    1SAM 201 904 R 1005

    1SAM 201 904 R 1006

    1SAM 201 904 R 1007

    10

    10

    10

    10

    10

    10

    10

    * Not suitable for panel mounting

  • 7/29/2019 Manual Motor Starters

    6/141SKC000013C0201

    1/93Automation Technologies

    MMS

    Manual Motor StartersMS 116 Accessories

    Ordering Details (continued)

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Undervoltage release with pre-mating auxillary switch 2S, lateral attachment at left

    24 V AC48 V AC

    60 V AC

    120 V AC

    230 V AC

    400 V AC

    415 V AC

    UA1-HK-24UA1-HK-48

    UA1-HK-60

    UA1-HK-120

    UA1-HK-230

    UA1-HK-400

    UA1-HK-415

    1SAM 201 905 R 10011SAM 201 905 R 1002

    1SAM 201 905 R 1003

    1SAM 201 905 R 1004

    1SAM 201 905 R 1005

    1SAM 201 905 R 1006

    1SAM 201 905 R 1007

    1010

    10

    10

    10

    10

    10

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Shunt release, lateral attachment left

    24 V 50/60 Hz

    110 V 50/60 Hz

    230 - 240 V 50/60 Hz

    350 - 415 V 50/60 Hz

    AA1-HK-24

    AA1-HK-110

    AA1-HK-230

    AA1-HK-400

    1SAM 201 910 R 1001

    1SAM 201 910 R 1002

    1SAM 201 910 R 1003

    1SAM 201 910 R 1004

    1

    1

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Locking device

    lock adapter

    locking device assembly

    SA1

    SA3GJF1 101 903 R 0001

    GJF1 101 903 R 0003

    10

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Direct adapter, for mounting of contactors

    mini contactors B6/B7

    contactors A9/A12/A16

    contactors A26

    BEA7/116

    BEA16/116

    BEA26/116

    1SBN 080 906 R 1000

    1SBN 081 406 R 1000

    1SBN 082 406 R 1000

    1

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Phase buses for cross wiring MS 116, 63 A, 690V

    for 2 devices without auxillary switches

    for 3 devices without auxillary switches

    for 4 devices without auxillary switches

    for 5 devices without auxillary switches

    for 2 devices with 1 auxillary switch

    for 3 devices with 1 auxillary switch

    for 4 devices with 1 auxillary switch

    for 5 devices with 1 auxillary switch

    for 2 devices with 2 auxillary switchesfor 3 devices with 2 auxillary switches

    for 4 devices with 2 auxillary switches

    for 5 devices with 2 auxillary switches

    PS1-2-0

    PS1-3-0

    PS1-4-0

    PS1-5-0

    PS1-2-1

    PS1-3-1

    PS1-4-1

    PS1-5-1

    PS1-2-2PS1-3-2

    PS1-4-2

    PS1-5-2

    1SAM 201 906 R 1002

    1SAM 201 906 R 1003

    1SAM 201 906 R 1004

    1SA M 201 906 R 1005

    1SAM 201 906 R 1012

    1SAM 201 906 R 1013

    1SAM 201 906 R 1014

    1SAM 201 906 R 1015

    1SAM 201 906 R 10221SAM 201 906 R 1023

    1SAM 201 906 R 1024

    1SAM 201 906 R 1025

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Power infeed blocks, 63 A, 690 V, stranded 25 mm2, flexible 16 mm2

    S1-M1, flat

    S1-M2, high

    1SAM 201 907 R 1001

    1SAM 201 907 R 100210

    10

  • 7/29/2019 Manual Motor Starters

    7/141SKC000013C0201

    1/94 Automation Technologies

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Cover for phase buses

    BS1-3 1SAM 201 908 R 10001 50

    Manual Motor StartersMS 116 Accessories

    Ordering Details (continued)

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Insulating enclosure IP 65

    light grey with rotary handle, triple lockable in OFF position, with N- and PE-terminal

    grey/black shrouded handle

    yellow/red shrouded handleOTPA 116 L2 M1

    OTPA 116 A2 M1

    1SCA 022 615 R 3860

    1SCA 022 615 R 3510

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Insulating enclosure IP 55

    light grey with cover, including DIN rail for manual motor starter or line protection devices

    for 4 modules, 72 mmfor 6 modules, 108 mm

    for 10 modules, 180 mm

    Set of neutral and earth terminals

    for QES 4/3 N

    for QES 6/3 N

    for QES 10/3 N

    QES 4/3 NQES 6/3 N

    QES 10/3 N

    SMO 4

    SMO 6

    SMO 10

    GHL 111 2304 R 0013GHL 111 2306 R 0013

    GHL 111 2310 R 0013

    GHL 430 1910 R 0004

    GHL 430 1910 R 0006

    GHL 430 1910 R 0010

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Plastic enclosure IP 40

    light grey with rotary handle, triple lockable in OFF position, with N- and PE-terminal

    for 4 modules, 72 mm

    for 6 modules, 108 mm

    for 8 modules, 144 mm

    PCD 4 N

    PCD 6 N

    PCD 8 N

    GHS 270 1921 R 0004

    GHS 270 1921 R 0006

    GHS 270 1921 R 0008

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Switch cubicle mounting kit IP 65with axial extension triple lockable in OFF position, locked in ON position

    Twist knob black

    Twist knob red/yellow

    axis 85 mm

    axis 105 mm

    axis 130 mm

    axis 180 mm

    driver *

    driver spindle 32 mm **

    OHB2AJM

    OHY2AJM

    OXS5X 85

    OXS5X 105

    OXS5X 130

    OXS5X 180

    MSMN

    MSOX

    1SCA 022 384 R 6940

    1SCA 022 384 R 7080

    1SCA 022 347 R 3570

    1SCA 022 347 R 3650

    1SCA 022 353 R 4540

    1SCA 022 353 R 4620

    1SAM 101 923 R 0001

    1SAM 101 924 R 0001

    1

    1

    1

    1

    1

    1

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Door mounting kit IP 65

    lockable in OFF position

    Twist Knob black

    Twist Knob red / yellowDMS 116-G

    DMS 116-Y

    1SAM 201 912 R 1000

    1SAM 201 912 R 1001

    1

    1

    * For accommodating spindle and attachment to Manual Motor Starters

    ** Is screwed directly onto the Manual Motor Starters

  • 7/29/2019 Manual Motor Starters

    8/141SKC000013C0201

    1/95Automation Technologies

    MMS

    Manual Motor StartersMS 325

    Ordering Details (continued)

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Open design, enclosure IP 20, resistant to changeable climates.

    Quick fastening on mounting rails DIN EN 50 022 35.MS 325 with thermal and electromagnetic trips, short-circuit proof up to 100 kA, resp. 50 kA*

    0.10... 0.16

    0.16... 0.25

    0.25... 0.40

    0.40... 0.63

    0.63... 1.00

    1.00... 1.60

    1.60... 2.50

    2.50... 4.00

    4.00... 6.30

    6.30... 9.00

    9.00... 12.50

    12.50... 16.00

    16.00... 20.00

    20.00... 25.00

    MS 325 - 0.16

    MS 325 - 0.25

    MS 325 - 0.4

    MS 325 - 0.63

    MS 325 - 1

    MS 325 - 1.6

    MS 325 - 2.5

    MS 325 - 4

    MS 325 - 6.3

    MS 325 - 9

    MS 325 - 12.5

    MS 325 - 16

    MS 325 - 20

    MS 325 - 25

    1SAM 150 000 R 1001

    1SAM 150 000 R 1002

    1SAM 150 000 R 1003

    1SAM 150 000 R 1004

    1SAM 150 000 R 1005

    1SAM 150 000 R 1006

    1SAM 150 000 R 1007

    1SAM 150 000 R 1008

    1SAM 150 000 R 1009

    1SAM 150 000 R 1010

    1SAM 150 000 R 1011

    1SAM 150 000 R 1012

    1SAM 150 000 R 1013

    1SAM 150 000 R 1014

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    0.347

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    MS 325 with thermal and electromagnetic trips, short-circuit proof up to 100 kA, resp. 50 kA*

    with auxiliary switch 1 NO + 1 NC front mounted

    0.10... 0.16

    0.16... 0.25

    0.25... 0.40

    0.40... 0.63

    0.63... 1.00

    1.00... 1.60

    1.60... 2.50

    2.50... 4.00

    4.00... 6.306.30... 9.00

    9.00... 12.50

    12.50... 16.00

    16.00... 20.00

    20.00... 25.00

    MS 325 - 0.16

    MS 325 - 0.25

    MS 325 - 0.4

    MS 325 - 0.63

    MS 325 - 1

    MS 325 - 1.6

    MS 325 - 2.5

    MS 325 - 4

    MS 325 - 6.3MS 325 - 9

    MS 325 - 12.5

    MS 325 - 16

    MS 325 - 20

    MS 325 - 25

    1SAM 150 005 R 0001

    1SAM 150 005 R 0002

    1SAM 150 005 R 0003

    1SAM 150 005 R 0004

    1SAM 150 005 R 0005

    1SAM 150 005 R 0006

    1SAM 150 005 R 0007

    1SAM 150 005 R 0008

    1SAM 150 005 R 00091SAM 150 005 R 0010

    1SAM 150 005 R 0011

    1SAM 150 005 R 0012

    1SAM 150 005 R 0013

    1SAM 150 005 R 0014

    1

    1

    1

    1

    1

    1

    1

    1

    11

    1

    1

    1

    1

    0.359

    0.359

    0.359

    0.359

    0.359

    0.359

    0.359

    0.359

    0.3590.359

    0.359

    0.359

    0.359

    0.359

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    AccessoriesRetrofittable accessories

    These parts can be procured in addition to the MS 325, they must be installed by the user.

    Auxiliary switches, for front mounting 1)

    1 NO + 1 NC

    2 NO

    HKF-11

    HKF-20

    1SAM 101 928 R 0001

    1SAM 101 928 R 0002

    10

    10

    0.020

    0.020

    * Not suitable for panel mounting

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Auxiliary switches, lateral attachment at left, max. 2 pieces attachable 2) 3)

    1 NO + 1 NC

    2 NO 4)

    2 NC

    HK-11

    HK-20

    HK-02

    1SAM 101 901 R 0001

    1SAM 101 901 R 0002

    1SAM 101 901 R 0003

    10

    10

    10

    0.031

    0.031

    0.031

    Setting range Type Code Ordering Details Packing Weight

    A... A Type No. unit 1pc/kg

    Signal contact for general tripped signal, lateral attachment at the left max. 1 piece attachable

    1 NO + 1 NC HK-11 1SAM 101 904 R 0003 10 0.0311) Not simutaneously with UA/UA and AA, not suitable for distributor installation

    2) Max. 1 piece in conjucntion with SK. SK must be mounted on first position

    3) Pre-mating normally open contacts

    4) Can be used together with UAF (power infeed at top) for safety circuit with Emergency Stop button (further information

    available on request)

  • 7/29/2019 Manual Motor Starters

    9/141SKC000013C0201

    1/96 Automation Technologies

    Description UC Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Undervoltage relaease, slide in 5)

    power infeed at bottom6)

    power infeed at top, resp.

    connection of external voltage

    UAUAF

    1SAM 101 902 R 04001SAM 101 903 R 0024

    1SAM 101 903 R 0048

    1SAM 101 903 R 0060

    1SAM 101 903 R 0110

    1SAM 101 903 R 0230

    1SAM 101 903 R 0400

    1SAM 101 903 R 0415

    1SAM 101 903 R 0500

    1010

    10

    10

    10

    10

    10

    10

    10

    Manual Motor StartersMS 325 Accessories

    Ordering Details

    400V~24 V ~

    48 V ~

    60 V ~

    110 V ~

    230 V ~

    400 V ~

    415 V ~

    500 V ~

    0.020.02

    0.02

    0.02

    0.02

    0.02

    0.02

    0.02

    0.02

    Setting range Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Open circuit shunt release, slide-in 7)

    24 ... 60 V AC/DC

    110 ... 240 V AC/DC

    AA

    AA

    1SAM 101 909 R 0001

    1SAM 101 909 R 0002

    10

    10

    0.02

    0.02

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Printadapter, for soldering on electronic plates

    for UA, AA or as N/LS terminal AS 1SAM 101 905 R 0001 10 0.030

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Locking device for MS 325

    lock adapter

    locking device assembly.

    (Adpter SA1 + padlock + 3 keys)

    SA1

    SA3

    GJF 101 903 R 0001

    GJF 101 903 R 0003

    10

    10

    0.004

    0.050

    5) Other voltages, in particular DC, on request

    6) In particular if used with socket busbar system smissline-S

    7) Recommendation: connection of external voltage via terminal support AS

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Printadapter, for soldering on electronic plates

    for MS 325 and aux. contacts PA 25 1SAM 101 903 R 0001 1 kit 0.030

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Phase buses for cross wiring MS 325, 63 A, 690 V

    for 2 devices without auxillary switches

    for 3 devices without auxillary switches

    for 4 devices without auxillary switches

    for 5 devices without auxillary switches

    for 2 devices with 1 auxillary switchfor 3 devices with 1 auxillary switch

    for 4 devices with 1 auxillary switch

    for 5 devices with 1 auxillary switch

    for 2 devices with 2 auxillary switches

    for 4 devices with 2 auxillary switches

    PS3-2-0

    PS3-3-0

    PS3-4-0

    PS3-5-0

    PS3-2-1PS3-3-1

    PS3-4-1

    PS3-5-1

    PS3-2-2

    PS3-4-2

    1SAM 101 937 R 0012

    1SAM 101 937 R 0013

    1SAM 101 937 R 0014

    1SAM 101 937 R 0015

    1SAM 101 937 R 00221SAM 101 937 R 0023

    1SAM 101 937 R 0024

    1SAM 101 937 R 0025

    1SAM 101 937 R 0032

    1SAM 101 937 R 0034

    10

    10

    10

    10

    1010

    10

    10

    10

    10

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Power infeed blocks, 63 A, 690 V, stranded 25 mm2, flexible 16 mm2

    for MS 325 and aux. contacts

    S3-M1, flat

    S3-M2, high

    1SAM 101 938 R 0001

    1SAM 101 938 R 0002

  • 7/29/2019 Manual Motor Starters

    10/141SKC000013C0201

    1/97Automation Technologies

    MMS

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Cover for bubars (For unused poles)

    BS3-3 1SAM 101 938 R 0003 1 50

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Connecting element from MS 325 to 3poles circuit-breaker S2

    for power infeed from top to bottom SZ - SM3 1SAM 101 938 R 0003 1 0.047

    Description Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Insulating enclosure IP 65

    With rotary handle, triple lockable in OFF position, with N- and PE-terminal

    Twist knob black

    Twist knob red/ yellowIB 325 - G

    IB 325 - Y

    1SAM 101 940 R 1000

    1SAM 101 940 R 1001

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Insulating enclosure IP 55light grey with cover, including DIN rail for manual motor starter or line protection devices

    for 4 modules, 72 mm

    for 6 modules, 108 mm

    for 10 modules, 180 mm

    Set of neutral and earth terminals

    for QES 4/3 N

    for QES 6/3 N

    for QES 10/3 N

    QES 4/3 N

    QES 6/3 N

    QES 10/3 N

    SMO 4

    SMO 6

    SMO 10

    GHL 111 2304 R 0013

    GHL 111 2306 R 0013

    GHL 111 2310 R 0013

    GHL 430 1910 R 0004

    GHL 430 1910 R 0006

    GHL 430 1910 R 0010

    Type Code Ordering Details Packing Weight Type No. unit 1pc/kg

    Plastic enclosure IP 40, light grey in panel design, including DIN rail

    for 4 modules, 72 mm

    for 6 modules, 108 mm

    for 8 modules, 144 mm

    PCD 4 N

    PCD 6 N

    PCD 8 N

    GHS 270 1921 R 0004

    GHS 270 1921 R 0006

    GHS 270 1921 R 0008

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Switch cubicle mounting kit IP 65

    with axial extension triple lockable in OFF position, locked in ON position

    Twist knob black

    Twist knob red/yellow

    axis 85 mm

    axis 105 mm

    axis 130 mmaxis 180 mm

    driver *

    driver spindle 32 mm **

    OHB2AJM

    OHY2AJM

    OXS5X 85

    OXS5X 105

    OXS5X 130OXS5X 180

    MSMN

    MSOX

    1SCA 022 384 R 6940

    1SCA 022 384 R 7080

    1SCA 022 347 R 3570

    1SCA 022 347 R 3650

    1SCA 022 353 R 45401SCA 022 353 R 4620

    1SAM 101 923 R 0001

    1SAM 101 924 R 0001

    1

    1

    1

    1

    11

    1

    1

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Direct adapter MS 325

    Direct adapter MS325 to B6/B7

    Direct adapter MS325 to A9/A12/A16

    Direct adapter MS325 to A26

    BEA 7/325

    BEA 16/325

    BEA 26/325

    1SBN 080 906 R 1001

    1SBN 081 406 R 1001

    1SBN 082 406 R 100

    * For accommodating spindle and attachment to Manual Motor Starters

    ** Is screwed directly onto the Manual Motor Starters

    10

    10

    10

    0.021

    0.031

    0.031

    Type Code Ordering Details Packing Weight

    Type No. unit 1pc/kg

    Direct adapter MS 325 , lockable in OFF position

    Twist Knob black

    Twist Knob red / yellowDMS 116-G

    DMS 116-Y

    1SAM 201 912 R 1000

    1SAM 201 912 R 1001

    1

    1

    Manual Motor StartersMS 325 Accessories

    Ordering Details (continued)

  • 7/29/2019 Manual Motor Starters

    11/141SKC000013C0201

    1/98 Automation Technologies

    Manual Motor StartersMS 116 / MS 325

    Wiring Digrams

    1) Open circuit shunt release

    2) Undervoltage release

    3) Undervoltage release with leading auxiliary switch 2 SV4) Indexing mechanism, only MS 325

    5) Auxiliary switch blocks for lateral attachment

    6) Tripped alarm switch block (signalling contact)

    7) Auxiliary switches which can be plugged on at the front

    8) Alarm switch for short- circuits and general tripping

    MS 325 with accessories in accordance with the

    adjacent caption

    Manual Motor Starters

    for switching direct current andsingle- phase alternating current

    MS 116 with accessories in accordance with theadjacent caption

  • 7/29/2019 Manual Motor Starters

    12/141SKC000013C0201

    1/99Automation Technologies

    MMS

    159

    85,645

    47,5 47

    52

    BEA7/116

    B6 / B7

    HKF1-11

    9918

    90

    81 85,6

    SK1-...

    HK1-...

    UA1-...

    HKF1-11

    177

    85,645

    75

    HKF1-11

    A9 ... A16

    BEA16/116

    Manual Motor StartersMS 116

    Dimensions Details

    MS 116 mounted with UA1.../ SK1.../ HK1.../ HKF1- 11

    Manual Motor Starters MS 116

    MS 116 mounted with contactor A9... A16 MS 116 mounted with mini contactor B6/ 7

    MS 116 with aux. contact HKF 1 for front mounting

  • 7/29/2019 Manual Motor Starters

    13/141SKC000013C0201

    1/100 Automation Technologies

    Manual Motor StartersMS 325

    Dimensions Details

    Switch cubicle mounting kit

    Manual Motor Starters MS 325with aux. contact HKF for front mounting

    Signalkontakt SKAuxiliary switch HK

    Printadapter PA 25

    Outer twist knobs Driver and wpindles

    0RXQWLQJGHSWKPP

    $[LDOOHQJWKPP

    'ULOOLQJSODQ

    GULYHU

    $[LVPP

    GULYHUVSLQGOHPP

  • 7/29/2019 Manual Motor Starters

    14/14

    MMS

    Manual Motor StartersAccessoriest

    Dimenions Details

    Door mounting kit

    Housing IP 65