Page 1: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

INSTALLATION MANUAL TWINTILE

Page 2: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

Length of Tile

1350 mm

Length of Cover

1260 mm

Width of Cover

321 mm

Minimum Pitch

15° (27 %)

QUBE / QUBE ACOUSTIC

Length of Tile

1470 mm

Length of Cover

1400 mm

Width of Cover

367 mm

Minimum Pitch

15° (27 %)

TWIN ACOUSTICD

D

D

D

D

STORAGEIf stored outside, it should be kept in a sheltered place and a well-sealed waterproof cover must be placed over the TWINTILE roofing tiles and accessories to keep them dry and prevent damage.

NON-STANDARD ELEMENTS When installing non-standard elements or gutters above the level of the roof, it is strongly recommended that materials that could cause corrosion (e.g. Cu, stainless steel...) are NOT used.

ROOF TRAFFICWhen moving around the roof, avoid avoid buckling the tiles by placing weight on the balls of the feet, directly over the batten, in the pans of tiles.

CUTTING WITH A SAWWhen cutting tiles with a metal cutting saw (which has been approved by the producer), special (tipped) metal cutting blades should be used. Cutting should be performed with the coated surface facing downwards to reduce the amount of swarf adhering to the coating. Failure to do so will result in rust stains on the tile surface.

WET SURFACEFor safty reasons is not recommended to walk or work on the roof when it is wet.

BATTENSThe recommended counter batten dimension is 50 x 80 mm. The minimum counter batten height is 25 mm.

Tile batten size is 40 x 50 mm (distance between rafters less then 900 mm).

LOCAL STANDARDSIt is strongly recommended that local building standards and regulations are always followed and fully complied with.

HANDLINGCare should be taken when handling the tiles to avoid damage to the surface. If minor damage does occur, the finishing kit should be used to repair it.

Type of Profile Batten Spacing – D

Strešniki QUBE / QUBE ACOUSTIC 321 mm

Strešniki TWIN ACOUSTIC 367 mm

Page 3: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

INSTALLATION DETAILS

EAVE

S FL

ASH

ING

INTE

RLO

CKI

NG

O

F TH

E TI

LES

TILE

LAY

ING

NAI

L PO

SITI

ON

ING

11 12 13 1 38 2

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 8 Underlay

11 Slopingbase12 Mesh13 EavesGuardFlashing

1

23

49

87

65

10

Page 4: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

RID

GE

(BAR

ELLS

)H

IP

(SPA

CER

S)RI

DG

E (L

ON

G V

RID

GE)

HIP

(R

IDG

E RO

LL)

1 2 3 4 5 76 8 918

1 2 3 4 5 76 8 918

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 4 AngleTrim 5 RidgeBatten

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 4 LongVRidge 5 RidgeBatten

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 4 AngleTrim 5 RidgeBatten

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 4 AngleTrim 5 RidgeBatten

6 Spacer 7 RidgeBracket 8 Underlay 9 Rafter18 ThinnerSupportBatten

6 Spacer 7 RidgeBracket 8 Underlay 9 Rafter18 ThinnerSupportBatten

6 Spacer 8 Underlay 9 Rafter14 VentilationSpace

6 RidgeRoll 8 Underlay 9 Rafter14 VentilationSpace

2 4 5 6 5 8 9 1431

2 4 5 6 5 8 9 1431

Page 5: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

GAB

LE

(SC

RIBE

D R

IDG

E EL

EMEN

T)W

ALL

FLAS

HIN

GG

ABLE

(BAR

GE

FLAS

HIN

G W

ITH

WAT

ER C

HAN

NEL

)VA

LLEY

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 8 Underlay

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 8 Underlay

9 Rafter14 VentilationSpace15 ScribedFlashing17 BargeBoard

9 Rafter14 VentilationSpace16 LongBargeBoardCoverCountersunk17 BargeBoard

17 15 3 9 14 8 1 2

17 16 3 9 14 8 1 2

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 8 Underlay 9 Rafter14 VentilationSpace21 FlashingwithWaterChannel22 SideFlashing23 WarmthInsulation

1

2

1 2

8

9

14 3 21 24 25 2322

24 SideWallStarterFlashing25 Sealant

1 QUBE / TWIN 2 TileBatten 3 VentilationSpaceBatten 8 Underlay 9 Rafter10 Valley14 VentilationSpace26 ValleySealingFoam27 SupportBoard

3 26 27 10 8 9 14

Page 6: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

ACCESSORIES

Round ridgeLength of cover: 380 mm•TWINACOUSTIC

Long V ridgeLength of cover: 1250 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Angle trimLength of cover: 380 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Short side (Left or Right) Length of cover: 367 mm•TWINACOUSTIC

Mono-pitched ridge Length of cover: 1250 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Long barge board cover countersunkLength of cover: 1250 mm•QUBEACOUSTIC•QUBE

Small sub-ridgeLength of cover: 1250 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Large sub-ridgeLength of cover: 1300 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Mini sub-ridgeLength of cover: 1250 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Side wall flashing scribed (left or right)Length of cover: 1101 mm•TWINACOUSTIC

Flashing Left or RightLength of cover: 1101 mm•TWINACOUSTIC

Flashing Left or RightLength of cover: 1284 mm•QUBEACOUSTIC•QUBE

Page 7: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

STANDARD COLOURS

Bordeaux red Terracotta Brown (bronze) Anthracite Black matt High-gloss black

Ultra UV-resistant super durable powder coating (> 80μm)ROOF TILES: TWIN ACOUSTIC / QUBE ACOUSTIC / QUBE

Sloping base/mountingLength of cover: 1250 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Valley gutterLength of cover: 1300 mm•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Transparent tileCoverage: 0,35 m2

•TWINACOUSTIC

Roof vent flange plumbingPipe cross-section: 150 x 150 mm•QUBEACOUSTIC•QUBE

Snow-stopperSteel, powder coated•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Nails on a reel325 pcs/pack (2,8 x 50 mm)•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Touch-up pen12 ml•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Roof ventilation elementFree ventilation area: 75 cm2•TWINACOUSTIC•QUBEACOUSTIC•QUBE

Page 8: MANUAL - TWINTILE · 1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 10 Valley 14 Ventilation Space 26 Valley Sealing Foam 27 Support Board 3 26 27 10 8

TIN

STAL

L C

E, 0

6-20

19

Michielenweg 3B-3700 Tongeren, Belgium

+32(0)12 24 18 [email protected]

www.twintile.com