mas doa total control for drugs of abuse testing · thermo scientific mas doa total control for...
TRANSCRIPT
Thermo Scientific MAS DOA TOTAL ControlFor Drugs of Abuse Testing
The Thermo Scientific MAS DOA TOTAL Control is a liquid, ready-to-use product available for use on a variety of instrument platforms utilized in
drugs of abuse screening and confirmatory testing.
Part of Thermo Fisher Scientific
• flexibility, choice and quality• 19 analytes with 4 distinct levels• drug-free and high positive levels• wide platform use
BN06281122011-7-1
Thermo Scientific MAS DOA TOTAL ControlFor Drugs of Abuse Testing
LabLink xL
Used in conjunction with MAS controls, Thermo Scientific LabLink xL web-bases QAP software fulfills various regulatory requirements for QC tracking, including peer data review.
• Getanexternalperspectiveonyourinternalday-to-day QC
• Troubleshootvariancesimmediatelywithvisibilityto a world-wide peer group of users
• AssessquicklyandeasilywhethershiftsinQCrecoveries are unique to your laboratory
• Reducetroubleshootingtimeandquicklyreleasepatient results
LabLink Extra
Thermo Scientific LabLink Extra web-bases QAP software works in unison with the LabLink xL Quality Assurance Program to provide a gateway for up to the minute support data for Thermo Scientific QC products and the LabLink xL QAP system.
• AccesstoonlineQCpackageinsertdocumentsand updates
• QualityControlhandlingandenhancedperformance recommendations
• LabLinkxLQCdatafilegenerationguidelines(LISandInstrumentOptions)
• Countryspecifictechnicalsupportcontactinformation available on demand
Diagnostics
Ordering Information
For more information please contact 1-800-232-3342, or email: [email protected]
www.thermoscientific.com/QC
U.S.A.46360 Fremont Blvd. Fremont, CA 94538 USATel. 800-232-3342Fax: 510-979-5002CanadaTel. [email protected]. + 49 851 88689 [email protected] Tel. + 61 2 9649 [email protected] Tel. + 34 93589 [email protected] KingdomTel. + 44 01727 [email protected]
©2011ThermoFisherScientificInc.Allrightsreserved.Copyrightsinandtoportionsoftheillustrationsareowned by a third party and licensed for limited use only to Thermo Fisher Scientific by Fantasy Stock.
Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
The new Thermo Scientific MAS DOA TOTAL Control is a multi-constituent urine toxicology control offering 19 analytes with 4 distinct levels at drug concentrations 25% below and above commonly used screening and SAMHSA cutoffs. A drug-free level and high positive level are also available (6 levels total).
MAS® DOA TOTAL Control is a liquid, ready-to-use product available for use on a variety of instrument platforms. Each level of control is individually packed which gives you the flexibility to choose your levels according to your drug screen panel cutoffs while keeping the number of control vials to a minimum.
Part # Level # Bottles / Sizes Storage /Stability MatrixDOAT-1 1
6 x18 mL 24 months @ 2 - 8° C
30 days @ 2 - 8° C openedHuman Urine
DOAT-2 2
DOAT-3 3
DOAT-4 4
DOAT-5 5
DOAT-6 6
DOAT-MP Multi Pack 1 bottle per level, 18 ml each
Constituent Cutoff Values Alternative Cutoff Levels
Standard & SAMHSACutoff Levels
Constituent Chemical L1 L2 Cutoff L3 L4 Cutoff L5 L6
Amphetamine d-methamphetamine
Nega
tive(
drug
-free
)
- 25
% be
low cu
toff
1000
+ 25%
abov
e cut
off
- 25%
below
cuto
ff
500
+ 25%
abov
e cut
off
Eleva
ted
Barbiturates Secobarbital 300 200
Benzodiazepine Nitrazepam 300 –
Benzodiazepine Oxazepam – 200
Buprenorphine Buprenorphine – 20
Cannabinoid(THC) 11-nor-9-COOH-D9-THC 25 50
Cocaine Benzoylecgonine 300 150
Cotinine Cotinine 500 –
Ethanol Ethanol 20 50
ETG EthylGlucuronide 500 1000
LSD LSD 0.5 0.5
Methadone Methadone 300 300
Methadone Metabolite EDDP 100 1000
Methaqualone Methaqualone 300 300
Opiates Morphine, free 300 2000
Oxycodone Oxycodone 100 300
PCP Phencyclidine 25 25
Propoxyphene Propoxyphene 300 300
Tricyclics Nortriptyline 300 1000
Get total control over choice, reliability, quality