maverick ii systems - now with inverter compressor technology · market-leading rooftop efficiency...

2
©2014 Daikin Applied. All Rights Reserved Maverick ® II systems - now with inverter compressor technology Market-leading rooftop efficiency solutions Daikin Applied continues to provide market-leading efficiency solutions by offering inverter compressors in rooftop systems that include Rebel™ (3-15 ton), RoofPak™ (16-75 ton), and now - Maverick II (26-50 ton). Inverter compressors modulate, delivering only the required energy to satisfy space conditions, providing for exceptional temperature/humidity control and lower operating costs. Lower operating costs Inverter compressors will reduce your building’s operation costs by saving energy: Use only the required energy to exactly match building load while minimizing over-cooling Low speed operation reduces energy consumption; soft start reduces energy needed for compressor in-rush power Minimal compressor cycling saves energy (also eliminates DX coil condensate re-evaporation) Improve operation and comfort control The modulating capacity of an inverter compressor eliminates constant on-off cycling and continually maintains the desired leaving air temperature (LAT), resulting in: • Better dehumidification and comfort control Extended compressor life via better expansion valve control and minimal cycling Operate quietly Inverter compressors provide superior reduction in sound levels: Sound levels at part-load operation are very low Irritating on/off compressor cycling is eliminated Outperform digital scrolls The energy efficiency of an inverter compressor is far superior to that of a digital scroll compressor. Digital scroll compressors have specific performance limitations that should not be overlooked when making compressor selections: Digital scroll compressors always operate at full speed and are less efficient at part-load applications To try to match building load, digital scrolls require more energy to load and unload the compressor in 5-20 second intervals As digital scrolls load and unload, audible noise levels fluctuate noticeably

Upload: others

Post on 28-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Maverick II systems - now with inverter compressor technology · Market-leading rooftop efficiency solutions. Daikin Applied continues to provide . market-leading efficiency solutions

©2014 Daikin Applied. All Rights Reserved

Maverick® II systems - now with inverter compressor technology

Market-leading rooftop efficiency solutionsDaikin Applied continues to provide market-leading efficiency solutions by offering inverter compressors in rooftop systems that include Rebel™ (3-15 ton), RoofPak™ (16-75 ton), and now - Maverick II (26-50 ton). Inverter compressors modulate, delivering only the required energy to satisfy space conditions, providing for exceptional temperature/humidity control and lower operating costs.

Lower operating costsInverter compressors will reduce your building’s operation costs by saving energy:

• Use only the required energy to exactly matchbuilding load while minimizing over-cooling

• Low speed operation reduces energy consumption;soft start reduces energy needed for compressorin-rush power

• Minimal compressor cycling saves energy (alsoeliminates DX coil condensate re-evaporation)

Improve operation and comfort control The modulating capacity of an inverter compressor eliminates constant on-off cycling and continually maintains the desired leaving air temperature (LAT), resulting in:• Better dehumidification and comfort control• Extended compressor life via better expansion valve

control and minimal cycling

Operate quietlyInverter compressors provide superior reduction in sound levels:

• Sound levels at part-load operation are very low• Irritating on/off compressor cycling is eliminated

Outperform digital scrollsThe energy efficiency of an inverter compressor is far superior to that of a digital scroll compressor. Digital scroll compressors have specific performance limitations that should not be overlooked when making compressor selections:

• Digital scroll compressors always operate at fullspeed and are less efficient at part-load applications

• To try to match building load, digital scrolls requiremore energy to load and unload the compressor in5-20 second intervals

• As digital scrolls load and unload, audible noiselevels fluctuate noticeably

Page 2: Maverick II systems - now with inverter compressor technology · Market-leading rooftop efficiency solutions. Daikin Applied continues to provide . market-leading efficiency solutions

GS-07F-0377V

©2014 Daikin Applied | (800) 432-1342 | www.DaikinApplied.com | ASP31-400

Rooftop air conditioning efficiency is measured by two rating metrics – IEER (integrated energy efficiency ratio) for both full-load and part-load operation where equipment operates at 98% of the time, and EER (energy efficiency ratio) for full-load operation where equipment operates at 2% of the time. Since most operating hours are un-der part-load conditions, part-load efficiencies that occur during 98% of the equipment’s operating time are the best measure of efficiency.

Maverick II units with inverter compressors provide up to 39% better IEER than the current requirement of ASHRAE’s 90.1 (2013) standard, and 72% better than ASHRAE’s 90.1 (2000) standard.

16

14

4

8

6

10

12

ASHRAE 90.1 2000compliant unit

Maverick II72% better

Maverick™ IIw/variable speed

inverter compressor

Rooftop unit e�ciencies

E�ci

ency

ASHRAE 90.1 2013compliant unit

</= 760 kBtu/h

IEER

Maverick II39% better

See how Daikin can save you money in your region each year with the below energy savings chart that compares a 50 ton Daikin Maverick II VAV unit with variable speed inverter compressor technology to a standard efficiency ASHRAE 90.1 (2013) compliant cooling only unit, and an older/vintage unit.

Energy savings across the country

Maverick II is an ideal rooftop solution for applications like schools, large office buildings, health care facilities, hotels, casinos, and data centers where energy efficiency, reliability, indoor air quality and acoustics are top priorities. Maverick II units are also configurable for 100% dedicated outdoor air systems with energy recovery, VAV, single-zone VAV, or CAV systems.

0

20,000

40,000

60,000

80,000

100,000

120,000

140,000

Annu

al E

nerg

y Co

nsum

ptio

n (k

Wh)

Older Vintage ASHRAE 90.1-2013 Maverick II

The REAL measurement criteria for Rooftop efficiencies

To learn more about our 3 - 75 ton rooftop systems with advanced inverter compressor technology, contact your local Daikin Applied sales office or visit www.DaikinApplied.com to find an office near you.