measurement of thermal conductivity of sapphire rods ii

8
Measurement of thermal conductivity of sapphire rods II Takafumi Ushiba The university of Tokyo at Hongo Tsubono Laboratory 2012/8/8 KAGRA Cryogenic Payload Meeting 1

Upload: willem

Post on 24-Feb-2016

50 views

Category:

Documents


0 download

DESCRIPTION

Measurement of thermal conductivity of sapphire rods II. Takafumi Ushiba The university of Tokyo at Hongo Tsubono Laboratory. Contents. Purpose of the measurement How to measure Result D iscussion Summary. Purpose of the measurement. Final goal - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Measurement of thermal conductivity of sapphire rods II

Measurement of thermal conductivity of sapphire rods II

Takafumi UshibaThe university of Tokyo at Hongo

Tsubono Laboratory

2012/8/8 KAGRA Cryogenic Payload Meeting 1

Page 2: Measurement of thermal conductivity of sapphire rods II

Contents

• Purpose of the measurement• How to measure• Result• Discussion• Summary

2012/8/8 KAGRA Cryogenic Payload Meeting 2

Page 3: Measurement of thermal conductivity of sapphire rods II

Purpose of the measurement

• Final goal   measure the thermal conductivity of Moltech and INPEX sapphire rods with nail head.• Near goal   measure thermal conductivity of polished Photoran’s sapphire rods near peak temperature to confirm the purity of sapphire rods is well or not.

2012/8/8 KAGRA Cryogenic Payload Meeting 3

Page 4: Measurement of thermal conductivity of sapphire rods II

How to measure

• Sample size   diameter :    sample length : 100mm• One dimensional approximation.

:thermal conductivityL :length between two temperature sensors,Q:heat flow,  A :sample cross section,:difference of values of two temperature sensors

L

temperature sensor

temperature sensor

heater

Q

Heat bath

2012/8/8 KAGRA Cryogenic Payload Meeting 4

Page 5: Measurement of thermal conductivity of sapphire rods II

How to measure

• Sample size   diameter :    sample length : 100mm• One dimensional approximation.

:thermal conductivityL :length between two temperature sensor,Q:heat flow,  A :sample cross section,:difference of values of two temperature sensor

temperaturesensor

heater

heat bath

2012/8/8 KAGRA Cryogenic Payload Meeting 5

Page 6: Measurement of thermal conductivity of sapphire rods II

Result

2012/8/8 KAGRA Cryogenic Payload Meeting 6

This time, I take three data near 30K.

Page 7: Measurement of thermal conductivity of sapphire rods II

Discussion

• Error bars   uncertainty of offset voltage of thermometer• Peak’s shape   If the offset voltage of thermometer does not depend on temperature, the shape of peak of thermal conductivity is same as the real peak.

2012/8/8 KAGRA Cryogenic Payload Meeting 7

Page 8: Measurement of thermal conductivity of sapphire rods II

Summary

• I measure thermal conductivity near 30K• The result has too large error bars because of

the offset voltage of the temperature sensor.• In this measurement, I do not confirm the

purity of sapphire rod is well or not.• So, I need to measure thermal conductivity of

sapphire rod again near 30K.

2012/8/8 KAGRA Cryogenic Payload Meeting 8