Measuring phenylalanine
R Neil DaltonThe WellChild Trust Laboratory
King’s College, London Evelina Children’s Hospital at Guy’s Hospital
NSPKU, Skipton, 26th February 2004
![Page 2: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/2.jpg)
Measuring phenylalanine
Phenylalanine
The bad boy of phenylketonuria?
![Page 3: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/3.jpg)
Measuring phenylalanine
Phenylalanine is an essential amino acidOne of the building blocks of all proteins
Essential that the blood level of phenylalanine is maintained at an optimum concentration
Optimum concentration range relatively wide, but in phenylalanine hydroxylase deficiency needs to be
routinely monitored
![Page 4: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/4.jpg)
Measuring phenylalaninephenylalanine 3D structure
![Page 5: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/5.jpg)
Measuring phenylalaninephenylalanine structure
![Page 6: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/6.jpg)
Measuring phenylalanine
Collection of the blood spot is the most important step in obtaining an accurate measurement of
phenylalanine in the blood
How do we actually measure it?
![Page 7: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/7.jpg)
Measuring phenylalanineGuthrie bacterial inhibition assay
![Page 8: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/8.jpg)
Measuring phenylalanineThin layer chromatography
![Page 9: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/9.jpg)
Measuring phenylalaninespotting the samples
![Page 10: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/10.jpg)
Measuring phenylalaninechromatography
![Page 11: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/11.jpg)
Measuring phenylalaninemethods
fluorimetry enzymatic (PAL, PDH) high pressure liquid chromatography
Electrospray mass spectrometry-mass spectrometry
![Page 12: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/12.jpg)
Measuring phenylalanine Electrospray (John Fenn)
![Page 13: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/13.jpg)
Measuring phenylalanineElectrospray Ionisation
![Page 14: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/14.jpg)
Measuring phenylalanineElectrospray Ionisation
![Page 15: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/15.jpg)
Measuring phenylalanineElectrospray Ionisation
![Page 16: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/16.jpg)
Measuring phenylalanineElectrospray Ionisation
![Page 17: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/17.jpg)
Measuring phenylalanineElectrospray Ionisation
![Page 18: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/18.jpg)
Measuring phenylalaninemass spectrometry-mass spectrometry
DETECTOR
MS1 Collision Cell MS2
IONS
Q1 Q2 Q3
![Page 19: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/19.jpg)
Measuring phenylalanineproduct ion scan
DETECTOR
Phe+ Collision Cell MS2
IONS
Q1 Q2 Q3
Q1 - selection of phenylalanine ion
Q2 – fragment the phenylalanine ions
Q3 – look for fragments of the phenylalanine
![Page 20: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/20.jpg)
Measuring phenylalanine product ion scan
![Page 21: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/21.jpg)
Measuring phenylalanine fragmentation
![Page 22: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/22.jpg)
Measuring phenylalanine
DETECTOR
Phe+ Collision Cell x+IONS
Q1 Q2 Q3
Q1 - selection of phenylalanine ion m/z 166
Q2 – fragmentation of phenylalanine ion
Q3 - selection of specific fragment ion m/z 120
![Page 23: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/23.jpg)
Measuring phenylalanine optimal phenylalanine control
![Page 24: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/24.jpg)
Checking in
Samples posted in are received at the laboratory and are logged in to the computer.
![Page 25: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/25.jpg)
Punching out spot
A special machine punches out the spots
![Page 26: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/26.jpg)
Measuring phenylalanine Sample Preparation
Punch 3mm diameter blood spot into deep-well (2ml) microtitre plate
Add 150l methanol/water (83:17) containing d5-phe and d4-tyr (5.6mmol/l)
Seal plate with lid and mix for 20min at 300 cycles/min
Place on Gilson autosampler at RT for injection
![Page 27: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/27.jpg)
Mixing and shaking
Samples are then put onto plates and mixed.
![Page 28: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/28.jpg)
Measuring phenylalanine Sample delivery & MSMS acquisition
Mobile phaseacetonitrile/water (1:1) with formic acid (0.025%)
Flow rate 50l/min Sample volume 2l Acquisition time 55s Cycle time 66s
Precursor product pairsphenylalanine (166/120) d5-phenylalanine (171/125)
tyrosine (182/136) d4-tyrosine (186/140)
![Page 29: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/29.jpg)
Measuring phenylalanine calibration
![Page 30: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/30.jpg)
Spiked blood spots run as unknowns (3/level/day)Blood spots from normal subjects (39-82/subject/day)
Data shown as median & range
0
200
400
600
800
1000
1200
1400
1600
02-05-1999 07-05-1999 12-05-1999 17-05-1999 22-05-1999 27-05-1999 01-06-1999 06-06-1999
Date
Phe
mol
/l
1200
600
400
300
200
240 cutoff
480 cutoff
Subject 3
Subject 2
Subject 1
![Page 31: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/31.jpg)
Measuring phenylalaninepoor phenylalanine control
![Page 32: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/32.jpg)
results
Sample results are then checked by the laboratory staff.
![Page 33: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/33.jpg)
Lab team
Our hard working biochemistry team.
![Page 34: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/34.jpg)
Reported results
Our dietitians have both a phoned and faxed report of all the day’s phenylalanine samples received
![Page 35: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/35.jpg)
Phoning parents
With all the results available, the dietitian phones the families, discusses both the child’s well being dietary changes if needed and often a bit of a social chit-chat.
![Page 36: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/36.jpg)
Measuring phenylalanine
A multi-disciplinary team of parents/individual, health care professionals, and leading edge
analytical technology are involved in maintaining optimal blood phenylalanine
Collection of the blood spot is the most important step in obtaining an accurate measurement of
phenylalanine in the blood
![Page 37: Measuring phenylalanine R Neil Dalton The WellChild Trust Laboratory King’s College, London Evelina Children’s Hospital at Guy’s Hospital NSPKU, Skipton,](https://reader035.vdocuments.net/reader035/viewer/2022062515/56649c755503460f94929766/html5/thumbnails/37.jpg)
Acknowledgements
Charles Turner
Sue Bird
The WellChild Trust
Charitable Foundation Guy’s & St Thomas’ Hospitals
Guy’s and St Thomas’ NHS Trust