medium intensity obstruction light miol - b / miol - c · miol-b miol-c con pannello solare.indd...

3
rev_00 C&E SRL - [email protected] - www.luxsolar.com - Ph. +39.0341.260926 MEDIUM INTENSITY OBSTRUCTION LIGHT MIOL - B / MIOL - C AIRCRAFT WARNING LIGHTS AWL - MIOL

Upload: others

Post on 16-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MEDIUM INTENSITY OBSTRUCTION LIGHT MIOL - B / MIOL - C · MIOL-B MIOL-C con pannello solare.indd Created Date: 4/26/2017 11:55:59 AM

rev_00 C&E SRL - [email protected] - www.luxsolar.com - Ph. +39.0341.260926

MEDIUM INTENSITY OBSTRUCTION LIGHTMIOL - B / MIOL - C

AIRCRAFT WARNING LIGHTS

AW

L - M

IOL

Page 2: MEDIUM INTENSITY OBSTRUCTION LIGHT MIOL - B / MIOL - C · MIOL-B MIOL-C con pannello solare.indd Created Date: 4/26/2017 11:55:59 AM

rev_00 C&E SRL - [email protected] - www.luxsolar.com - Ph. +39.0341.260926

AIRCRAFT WARNING LIGHTS

MIOL - B / MIOL - CKEY FEATURES

• Based on LED technology• RED light - 2.000cd• Long LED life time >10 years life

expectancy• Low consumption • Stabilised light output• Easy to install• No RF-radiations• Autonomy: 3 days related to the location• Patented beacon:

EU 001929910-0001; Canada 145 189; USA D673,474; Turkey TR2012 05662

OPTICAL FEATURES

OPTIONS

MECHANICAL FEATURES

APPLY TO

CERTIFICATIONS - BEACON

COMPLIANCE - BEACON

ELECTRICAL FEATURES

• Cd emission -0,5° and +4°• Horizontal beam radiation 360°• Optical lens

• Twin version: two galvanically separate circuits in the same fi xture

• Fault alarm• Infrared available• Automatic changeover from normal to

backup light

• Beacon borosilicate glass cover protection

• Degree of protection: IP66• Operating temperature beacon: -20°C to

+50°C• Storage temperature: -25°C to +55°C• Lamp unit weight complete with solar

and control system: 50kg

• Airport - Stack - High Building - Chimney - Tower crane

• Pipe line - Bridge - Radio and television tower

• Transmission line - Wind turbine - Wind mast measurement

• Radar - Antenna

• DGAC/STAC approval nr. 2013A037• ENAC approval nr. 0135182/ENAC/CIA• CE marking

• ICAO Aerodromes -Annex 14 Vol. 1, Chap. 6: Medium intensity, Type B fl ashing obstacle light MIOL-B type or Type C steady burning obstacle light MIOL-C type

• FAA AC150/5345-43F E.B. #67 type L-864 o Twin L-864

• Licensing of aerodromes - CAP168 - Chapter 4

• Power Supply from battery pack • Power consumption MIOL-B 4W/h @3fpm

and MOL-C 24W/h• LED feeded at costant current

AW

L - MIO

L

Page 3: MEDIUM INTENSITY OBSTRUCTION LIGHT MIOL - B / MIOL - C · MIOL-B MIOL-C con pannello solare.indd Created Date: 4/26/2017 11:55:59 AM

rev_00 C&E SRL - [email protected] - www.luxsolar.com - Ph. +39.0341.260926

AIRCRAFT WARNING LIGHTS

MIOL - B / MIOL - C

Order code

1 2 3 4 5 6

1 = Without alarm

12VDC = 1

L864-LXS-SOL

2.000cd Flashing= B

2.000cd Steady Burning = CManufacturer code

S = Single light

T = Twin light

0 = With alarmRed = R

I = Visible light + infrared LEDs

AW

L - M

IOL

1 R