megadome design guide 2015 v2

8
www. megadome .bworxx.com | megadome @bworxx.com 604.794.3628 Toll Free 888.500.1155 DESIGN GUIDE

Upload: colin-timms

Post on 13-Apr-2017

274 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MegaDome DESIGN GUIDE 2015 V2

www.megadome.bworxx.com | [email protected]

604.794.3628Toll Free 888.500.1155

DESIGN GUIDEwww.megadome.bworxx.com | [email protected]

604.794.3628Toll Free 888.500.1155

DESIGN GUIDE

Page 2: MegaDome DESIGN GUIDE 2015 V2

CHOOSING THE RIGHT MEGADOME

megadome.bworxx.com 2

B

2’4’

A D

LPHD 50 60 70 80

A (2’) 4’6” 4’6” 4’6” 4’6”B (4’) 7’1” 7’1” 7’1” 7’1”

C 17’7” 19’3” 20’10” 22’6”

D 19’7” 21’3” 22’10” 24’6”

base truss 16” 24” 16” 24” 16” 24” 16” 24”

LOW PROFILESLP

C

LD - 2 3/4 x 1 5/8 14 ga

HD - 3 9/16 x 2 14 ga

HHD - 4 5/16 x 2 3/4

100 - 5 5/16 x 3 8 ga*

16”24”30”33”

TRUSS DIMENSIONS

TRU

SS C

HO

RD

S

TRU

SS D

EPTH

14 ga11 ga*

* Denotes hot-dip galvanized

• Select building Width— 30, 33, 35, 40, 50, 60, 70, 80, 90, 100, 125, or 140'.• Select building Profile— LP (Low), HP (High), XP (Extra High), or XXP (Exxtra High).• EZ-Domes are single-tube arch frames available for 30, 35 and 40’ widths.• The 100+ Series—available in 100’, 125’ and 140’ widths— are only available with heavy-duty 8 ga. large section tubular framing.• Model XP100 (with nominal 100’ width) is actually 30 metres (98’-5”) wide.• Most models are available with optional Hot-Dip or Hot-Dip+ finishes for extra protection. Ask for details.• Truss spacing, truss depths and tube sections (LD, HD, HHD) are primarily a function of engineering design based on the applicable

climatic data and other imposed loads.

3 604.794.3628 888.500.1155

LD & HD50607080A (2’)7’2”7’2”7’2”7’2”B (4’)9’10”9’10”9’10”9’10”

C20’9”22’4”24’0”25’7”

D22’9”24’4”26’0”27’7”

basetruss13”24”13”24”13”24”13”24”

C

2’4’

B AD

C BD A

HPHIGH PROFILES

XXPEXTRA HIGH PROFILES

HHD60708090A (2’)6’1”6’1”6’1”6’1”B (4’)9’3”9’3”9’3”9’3”

C21’9”23’5”25’26’8”

D24’3”25’11”27’6”29’2”

basetruss13”30”13”30”13”30”13”30”

HHD60708090A (2’)17’1”17’1”17’1”17’1”B (4’)20’3”20’3”20’3”20’3”

C32’9”34’5”36’0”37’8”

D35’3”36’11”38’6”40’2”

basetruss13”30”13”30”13”30”13”30”

Page 3: MegaDome DESIGN GUIDE 2015 V2

3604.794.3628 888.500.1155

LD & HD 50 60 70 80A (2’) 7’2” 7’2” 7’2” 7’2”B (4’) 9’10” 9’10” 9’10” 9’10”

C 20’9” 22’4” 24’0” 25’7”

D 22’9” 24’4” 26’0” 27’7”

base truss 13” 24” 13” 24” 13” 24” 13” 24”

C

2’4’

BA D

CB DA

HP HIGH PROFILES

XXP EXTRA HIGH PROFILES

HHD 60 70 80 90A (2’) 6’1” 6’1” 6’1” 6’1”B (4’) 9’3” 9’3” 9’3” 9’3”

C 21’9” 23’5” 25’ 26’8”

D 24’3” 25’11” 27’6” 29’2”

base truss 13” 30” 13” 30” 13” 30” 13” 30”

HHD 60 70 80 90A (2’) 17’1” 17’1” 17’1” 17’1”B (4’) 20’3” 20’3” 20’3” 20’3”

C 32’9” 34’5” 36’0” 37’8”

D 35’3” 36’11” 38’6” 40’2”

base truss 13” 30” 13” 30” 13” 30” 13” 30”

3 604.794.3628 888.500.1155

LD & HD50607080A (2’)7’2”7’2”7’2”7’2”B (4’)9’10”9’10”9’10”9’10”

C20’9”22’4”24’0”25’7”

D22’9”24’4”26’0”27’7”

basetruss13”24”13”24”13”24”13”24”

C

2’4’

B AD

C BD A

HPHIGH PROFILES

XXPEXTRA HIGH PROFILES

HHD60708090A (2’)6’1”6’1”6’1”6’1”B (4’)9’3”9’3”9’3”9’3”

C21’9”23’5”25’26’8”

D24’3”25’11”27’6”29’2”

basetruss13”30”13”30”13”30”13”30”

HHD60708090A (2’)17’1”17’1”17’1”17’1”B (4’)20’3”20’3”20’3”20’3”

C32’9”34’5”36’0”37’8”

D35’3”36’11”38’6”40’2”

basetruss13”30”13”30”13”30”13”30”

Page 4: MegaDome DESIGN GUIDE 2015 V2

megadome.bworxx.com 4

CBA D

LD & HD 33 40 50 60 70 80A (2’) 13’11 13’11 12’7” 12’7” 12’7” 12’7”B (4’) 16’4” 16’4” 15’3” 15’3” 15’3” 15’3”

C 21’9” 22’9” 25’9” 27’5” 29’0” 30’8”

D 23’1” 24’1” 27’9” 29’5” 31’0” 32’8”

base truss 16” 16” 16” 16” 16” 24” 16” 24” 16” 24” 16” 24”

HHD 60 70 80 90 100 (30m)A (2’) 11’9” 11’9” 11’9” 11’9” 11’8”B (4’) 14’8” 14’8” 14’8” 14’8” 14’7”

C 26’9” 28’5” 30’0” 31’8” 36’0”

D 29’3” 30’11” 32’6” 34’2” 38’6”

base truss 17” 30” 17” 30” 17” 30” 17” 30” 17” 30”

100 +

100 125 140

A B C

100 125 140A (4’) 17’6” 17’6” 17’6”

B 46’11” 50’0” 51’8”

C 50’6” 54’7” 56’2”

base truss 7” 33” 7” 33” 7” 33”

XP HIGH PROFILES

SERIES

4’

100(30m)

Page 5: MegaDome DESIGN GUIDE 2015 V2

5604.794.3628 888.500.1155

HP

LockBlock Precast Concrete

LP

Poured Concrete Footing & Wall

XP

Slab on Grade with Grade Beam

Note: All walls will be designed/engineered to suit building use, soil bearing capacity and MegaDome dead & live weights.

FOUNDATIONS

Concrete Piers

XP

Wood Foundation

LP

EZ-DOMES

EZ-Domes are a range of single-tube arch frame structures for 30, 35 and 40’ widths. They are manufactured with heavy duty 4 5/16” HDD galvanized steel oval tubes for superior rigidity. All EZ-Domes are supplied with the same fabric cover options, and warranties, as the standard MegaDome arch-truss buildings.

30 35 40A (4’) 10’3” 11’3” 12’2”

B 14’9” 17’3” 19’8”

BA

4’

XLLD 40

A (2’) 6’0”

B (4’) 8’6”

C 14’11”

D 16’3”

base truss 16” 16”

A BC D

EXTRA LOW PROFILES

40

LP

Page 6: MegaDome DESIGN GUIDE 2015 V2

megadome.bworxx.com 6

All MegaDomes are CAN/CSA A660 certified, in conformance to the National Building Code of Canada (NBCC) requirements for all pre-engineered building—ensuring strict quality performance for engineering, manufacturing and assembly. The major Material Quality Standards, such as CSA, ASTM, ULC, AWPA, NFPA, and NBCC are adhered to. MegaDomes are Canadian Welding Bureau (CWB) certified.

P. Eng. signed & sealed construction drawings are available for each project, together with Letters of Assurance of Professional Design and Commitment for Field Review (Schedules B1 & B2), if required by the Building Inspector.

Designed for your project’s location. MegaDomes are designed for snow, rain, and 30/50 year wind loads for YOUR project’s specific location —in accordance with Appendix C

(Climatic Design Data) of the National Building Code of Canada.

ENGINEERING & CERTIFICATION

MegaDome®is a registered trademark of the manufacturer,

Harnois Industries Ltd.

ADDITIONAL OPTIONS

Side Door

Your MegaDome® can be built to suit any need. Doors can be installed on gable ends and/or sides, and can be installed to swing, slide or roll-up. MegaDome® may also be fitted with lighting fixtures, fire sprinklers and different types of ventilation options.

Widespan Vinyl Roll-up DoorSectional Steel Overhead Door

Louvers Ventilation Mesh

Doors

Man Door

Ventilation

Ridge Vent (fixed or motorized)

Page 7: MegaDome DESIGN GUIDE 2015 V2

7604.794.3628 888.500.1155

MegaDomes are covered with ultra-durable POWERSHIELD® 12 oz/sq.yd woven polyethylene fabric. Some of the colors offered are translucent membranes – which let in natural daylight; are cooler in summer time, and which reduce energy costs. Other colors, featuring a black intermediate layer, are opaque. The interior color of all membranes are white.

Membrane OptionsColour Transparency Warranty

WHITE translucent 2-15

SILVER s-opaque 2-15

GREEN s-opaque 2-15

SANDSTONE translucent 2-10

BLUE opaque 2-10

FIRE-RETARDANT (FR) FABRIC COVERINGSconform to CAN/ULC S-109 and NFPA 701 standards.

FR-WHITE translucent 2-15

FR-GREEN opaque 2-10

FR-SANDSTONE translucent 2-10

FR-BLUE opaque 2-10

Membrane WarrantyThe manufacturer warranties the performance of the fabric covering as follows: 100% replacement warranty for the first 2 years; and thereafter up to 15 years in total on a pro-rated basis—refer to the table above for the specific warranty that applies to different colors and products.

white

silver

green

sandstone

FR blue/blue

MEMBRANE COVERS

MegaDomes offer excellent resistance to corrosion. As a standard for effective general corrosion protection, low temperature silicone-bronze welding in conjunction with pre-galvanized steel is employed in the manufacturing of the MegaDomes® arch-frames.

For superior protection and for corrosive environments, hot-dip galvanizing, with a 4 mil. thick zinc coating, applied after fabrication and welding is available. This provides a life expectancy of 50 years, in general use; and 25 years in industrial use.

CORROSION PROTECTION

Pre-galvanized steel with silicon-bronze welding.

Hot-dip galvanized steel.Note: In an effort of continual improvement all information contained herein is subject to correction or change, at any time, without notice. All representations, warranties, and scope of products and services, made herein shall be confirmed by the customer and BuildWorks at the time of purchase. ©2014. Buildworks Construction Inc. V 2014.3

Page 8: MegaDome DESIGN GUIDE 2015 V2

Loc

k Bl

ocks

Pou

red

conc

rete

& w

all

Gra

de B

eam

Woo

d Fo

unda

tion

Con

cret

e Pi

ers H

P L

P X

L

70

80

90

100

125

140

by B

uild

Wor

ks

MO

DEL

100

+ X

XP X

P

WID

TH 3

0 3

3 3

5 4

0 5

0 6

0

LEN

GTH:

604.

794.

3628

m

egad

ome@

bwor

xx.c

om

meg

adom

e.bw

orxx

.com

PRO

JECT

:

TITL

E:

DAT

E:

NO

:

Free Plain Graph Paper from http://incompetech.com/graphpaper/plain/

NO

T TO

SC

ALE

BY:

NO

TES

FOU

NDA

TIO

NS

ft