Dielectric Oil Test Set FamilyModel OTS
![Page 2: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/2.jpg)
2
Agenda for Discussion
ApplicationsCustomersOTS Product Range ImprovementsCustomer Common Key IssuesCustomer Issues Resolved by OTSKey FeaturesOTS Configured to Order
![Page 3: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/3.jpg)
3
What is the test looking for?
Aging and / or oil contamination by changes in…• Electrical properties
–Moisture content–Chemical contamination–Solids & particles
Change in conditions inside apparatus due to..• Arcing • Overheating • Vibration
![Page 4: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/4.jpg)
4
How is the Test PerformedThe test involves application of a rising voltage (at a set rateof rise) across a specially shaped brass electrodes within a container of a specific volume.For specific standards, the oil is circulated within the container – to replicate convection seen in oil within transformers.The test is repeated for a pre-determined number of times, waiting between tests and averaging the results.The pass/fail is pre-dermined for specific international standards, and differs for different customers.
Electrodes used within different standards
![Page 5: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/5.jpg)
5
Why test the oil breakdown voltage?
A quick and easy test for equipment in service for:• Detecting oil moisture and contaminant content before
catastrophic failure• Predicting remaining transformer life• Maintaining equipment safety• Fire prevention• Maintaining reliability
Checking new oil prior to filling new equipmentAcceptance of new oil deliveries
• Bulk oil shipments• Separate drum filling of small tank• Re-processing of used oil
![Page 6: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/6.jpg)
6
Applications
Testing dielectric strength of oil used in:• Super-grid transformers in Transmission systems• Distribution transformers at Regional Electrical sites• Regulating transformers• Instrument transformers• Reactors• Circuit breakers• Cables• Bushings• Capacitors
![Page 7: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/7.jpg)
7
What does the oil do?
Used as an insulation mediumCooling by circulation
![Page 8: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/8.jpg)
8
Customers
Utility contractors• Substations mainly
Power Utilities• Power Stations mainly
Service ProviderRail Companies
• Including locomotive HV step down transformers and switchgearOil test Lab / House / Company
• Providing testing service to all of the aboveTransformer / switchgear Manufacturer (OEM)Oil companies
• Testing new oil during manufacturing
![Page 9: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/9.jpg)
9
Product Range ChangesMegger Old Range
• Laboratory instruments– OTS60AF/2– OTS80AF/2– OTS100AF/2
• Portable instruments– OTS60PB
– OTS60SX
Megger New Range• Laboratory instruments
– OTS60AF– OTS80AF– OTS100AF
• Portable instruments– OTS80PB
– OTS60PB
– OTS60SX Continues
![Page 10: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/10.jpg)
10
Customer Common Key Issues1. Too heavy/bulky for field use2. “Oil testing is a messy business”3. Unreliable results4. Standard testing is complex5. Instrument is too fragile6. Ease of test result recording and reporting 7. Ownership costs8. Change of test standards
![Page 11: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/11.jpg)
11
1. Heavy to carry (portable use)
New Portable Units Lightest in the World• OTS60PB from only 15.38 kg• OTS80PB from only 19.48 kg
Important Health and Safety issue Even the OTS100AF from only 29.58kgNew ergonomic integral side handles
• Provides natural lifting position
![Page 12: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/12.jpg)
12
1. Heavy to carry (portable use)
Visual size / weight differences
OTS80PB OTS60PBOTS60AF OTS80AF OTS100AF
From 65 lb
From 42.9 lb From
33.9 lb
Laboratory unit Portable unit Portable unit
![Page 13: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/13.jpg)
13
1. Heavy to carry (portable use) - cont
Optional padded carry bag for portable unitsOptional transport case for portable units
![Page 14: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/14.jpg)
14
2. “Oil testing is a messy business”
All OTS range share common test vessel featuring:• Unique easy pour spout• Unique easy clean shape
![Page 15: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/15.jpg)
15
2. “Oil testing is a messy business” ……continued
OTS have unique test chamber drain• Easy removal of accidentally spilt oil• Pipe located on rear of instrument• Could be plumbed into laboratory waste oil system
![Page 16: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/16.jpg)
16
2. “Oil testing is a messy business” ……continued
Unique test chamber design shaped for easy clean• No sharp edges or contours
![Page 17: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/17.jpg)
17
2. “Oil testing is a messy business” ……continued
ASTM D1816 testing Fill oil to level mark and fit impeller lidBaffle excludes air without displacing oil from vessel
No mess, baffle sits on oil
![Page 18: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/18.jpg)
18
3. Reliable test resultsPrecision electrode gap adjustment
• Quick and easy to adjust
Unique electrode gap locking mechanism• Prevents gaps moving through handling• Prevent accidentally moving adjustment
• New accurate and smooth gap gauges
Precision thumb wheel electrode gap adjustment
Gap is then locked with unique mechanism
Precision thumb wheel electrode gap adjustment
Gap is then locked with unique mechanism
![Page 19: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/19.jpg)
19
3. Reliable test results …..continued
Transformer Design• Limit dissipated power in arc• Reliability, more rugged
Direct Output Breakdown Detection• Improved accuracy• High speed disconnection time
Breakdown detection both in terms of current and voltage
• Compliance with ASTM and IEC requirements
![Page 20: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/20.jpg)
20
3. Reliable test results …..continued
Optional new voltage calibration meter VCMD100• Not oil filled so no leaks• Highly visible LED display• Digital for ease of reading• Confidence in results
Built in automatic temperature measurement• Auto recorded on all test results• Standards specify temperature of sample• E.g. IEC require 20 ºC ± 5 ºC
![Page 21: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/21.jpg)
21
4. Standard Testing is too ComplexOTS Portable user interface
Clear colour displayEasy navigation keysIntuitive menu system
OTS Laboratory user interface
Additional keys for easy data entry
![Page 22: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/22.jpg)
22
5. Instrument is too fragile
Internal transformers and components able to handle rugged transport Extremely strong Polycarbonate display and chamber lidLarge impact absorbing corner mounted rubber feetImpact and chemical resistant plastic test vessels
![Page 23: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/23.jpg)
23
5. Instruments are too fragile - cont
Tough chemical resistant key padsOptional transport case for portable unitsOptional padded carry bag for portable units
![Page 24: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/24.jpg)
24
6. Test result recording and reporting
Test results are saved to: • Internal memory• USB stick
– Saves carrying the portable instrument into the office
• or a print outAll at the press of a buttonCan accommodate up to 10 breakdownsBar Code Scanner – fast automated results
Scrolled down on display
![Page 25: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/25.jpg)
25
6. Ease of test result recording and reporting …….continued
All OTS AF* come with PowerDB Lite as standard• Quickly produce professional report forms
All new OTS PowerDBcompatible
* OTS PB TBA
![Page 26: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/26.jpg)
26
7. High Cost of Ownership
More robust design means less likely to be in the repair shop, less transport cost to and from repair shop, more trusted resultsHigh quality, built to last, no need to replace for many years to come.New breakdown tolerances and voltage accuracy means less doubt in results, and faster testing when readings are questioned. Low cost additional or replacement test vessels.
![Page 27: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/27.jpg)
27
8. Change to Test Standards
Preloaded standards can be updated via a USB memory stickNew standards can be updated via a USB memory stickUsers can produce new custom tests by adding new or modifying an existing one and saving to new test nameNew or amended standards may be downloaded from www.megger.com
![Page 28: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/28.jpg)
28
CONCLUSION - Key Features
1. Lightest portable (PB) models in market2. Precision test vessel with lockable electrode
gap setting3. Transfer of results via USB flash drive plus
updating new test standards 4. Ultra fast (< 10 μs) HV switch off time –
Consistent results5. USB barcode scanner (AF only) 6. All new OTS share common accessories7. VCM100D / VCM80D check meter (option)8. Automatic oil temperature sensing 9. Sunlight readable colour display and intuitive
user interface
![Page 29: Megger regidez dielectrica oil test- OTS seminar](https://reader035.vdocuments.net/reader035/viewer/2022081801/54c4779b4a795930358b460b/html5/thumbnails/29.jpg)
29
New OTS Configured to Order
Flexible order options to suit customer requirements and / or budget
Order code configuration determined on Data sheet
OTS60PB OTS80PB OTS60AF OTS80AF OTS100AFConfigured items Options
Built inNot fitted
NiMH (light weight)Lead Acid (low cost)Mains supply only
UK plug fittedEU Schuko plug fitted
US plug fittedAustralian plug fitted
No plug fittedSupplied
Not SuppliedASTM (cylindrical and mushroom)
IEC (Spherical and mushroom)Full set (ASTM and IEC)
SuppliedNot Supplied
Electrode set (shape) supplied
Carry case
Battery
Mains / Line supply lead
Printer
Vessel lid mounted impeller stirrer