Mekar Quoting and Configurator Mekar Quoting is an on-line tool to generate, save, edit, duplicate quotations of units for the HVAC applications. Mekar Quoting can be used by means of Microsoft Internet Explorer 6 Mekar Quoting can be entered with proper ID and password. Please contact Mekar srl ( [email protected] or +39 045 6630536 ) to get it. Mekar Configurator is a software for the configuration of air handling units units MEKAR 23MK series. The Mekar Configurator shall be installed locally through the proper setup which can be downloaded in his updated version from the Mekar’s website with a proper password. Although locally installed, Mekar Configurator can be started only through Mekar Quoting or with a proper web page. The Mekar Configurator is installed in C:\Program files\MEKAR Configurator In the same folder, the directory C:\Program files\MEKAR Configurator\Project will contain all the documents generated by the configurator.
Mekar Quoting
?? Customers database ?? Projects database ?? Quotations for ahu and
other HVAC products ?? Quotation printouts
Mekar Configurator
?? Single ahu selection ?? Technical printouts
Starting the configuration
Saving the configuration
Quoting Main menu
Messages from System administrator Database of
contacts / possible cli-ents
Database of existing cus-tomers
Database of the projects
Database of quotations
The menus without comments are for inter-nal use only
Quoting Adressees menu
This field to avoid duplication of adressees
You can search among the existing records or add a new one.
Remember that you cannot issue an offer without input the ad-dresse or the customer name.
Quoting Jobs menu
You can search among the existing records or add a new one.
Remember that you cannot issue an offer without indicating the project/job.
Quoting Proposal menu show mode
You can search among the existing records or add a new one.
If you open an existing offer the printable page opens.
To edit it, click on Mod-ify .
To print it, click at S at bottom part of the page.
Modify
Quoting Proposal Menu edit mode
Creates a new empty offer
Add a new ahu
Modify name of customer, project etc.
Modify or just open the shu configuration
Duplicate the ahu configuration (a new line will be added)
Add a new line with a product fo be searched in the product database
Add a line with comments
Add a line with a free product (just input a de-scription and a price)
Modify the order of the lines within the actual proposal
Saves the proposal (the actual will be overwritten)
Saves the proposal with a new ID and base_ID at revision index 1 (= first issue). To be used to transmit the same offer to a different customer, after changing the heading
Saves the proposal with a new ID but same base_ID at increased revi-sion index 2 (= second issue) or 3, 4……..
Click here to enter the discount window. Discounts can be different line by line
Quoting Proposal Menu Heading
General options for the proposal / supply
Modify name of customer, project etc.
General comments on the proposal
To change language
Air volume
Face velocity
To save the configuration and exit (or go back to the Quoting module)
Exit without saving
AHU model
Configurator Main menu
Item
Ahu front dimensions
Inspection and header side To show and save as .pdf the data sheet
To show and save as .pdf the psycrometric charts
To generate and save as dxf the general layout drawing with the required format (A1, A2 or A3)
To show the control schematic diagram (for units with controls)
To show and save the wiring diagram (for units with controls)
To show and save as .pdf the detailed price calculation (for authorized users only)
To save as .pdf the production documents (for authorized users only)
To save as .pdf the use and nstallation manual
To save notes and comments with or without prices
To calculate the unit
To add a component
To move a compo-nent within the unit
To delete a component
To delete the whole configuration
To select the ahu size
To input the return and fresh air conditions
To change the air volume in an existing configuration
To specify the casing type
To define the electronic controls
To check the dimensions and split the unit in more sections
Outputs
General inputs Components menu
Ahu menu
1. Input the item reference
2. Select the type of unit
3. Input the supply (and return if rele-vant) air volumes
4. input the maximum acceptable dimensions (if there are space limitations for the installation). In this way all ahu sizes which sat-isfy those limits will be shown. Otherwise only the basic sizes, with a face velocity near to the required one.
Type of unit
Air volume
Required face velocity
Max acceptable dimensions (0=no limits)
Inspection and header’s side
Item ref.
Configurator Start configurating
1. Click on Select size Select size Select size button
2. Select the size of unit according to the coil face velocity or width and height. Note that some component are not available at all sizes (right columns of the list)
Configurator Size selection
To show the size selection menu
Ahu size Components not available on the full ahu range
1. After the size selection, the com-ponent selection menu is shown.
2. Select the components moving their icons in the layout window. The components don’t need to be placed exactly one against the other
Configurator Components selection
Component selection menu: move the icons of the components in the upper window in the order you need.
Some components show a second level window for a first specification of the single component
Layout window
1. After the components selection, proceed with their further defini-tion and calculation by clicking on Calculate Calculate Calculate button.
2. A different window for each com-ponent will appear following the direction of air, except for the fan sections which are the last to be calculated since the pressure drop of every component must be con-sidered. In this window you can input the operating data, some geometric condition (like damper position for mixing box) and select the accessories.
3. Press CalculateCalculateCalculate button on the component window
4. If the solution is satisfactory, press ConfirmConfirmConfirm to proceed with the next component, otherwise change some input and re-calculate. In some cases you can select your preferred solutions from the list at the bottom part of the window. The CancelCancelCancel button, if used on an existing selection, just confirms the previous choice.
Note: After finishing the calculation of the unit, it is stil possible to edit one single component: just click on it in the layout window; the detail will be shown and again with the button CalculateCalculateCalculate you can re-calculate it. If the new calòculation gives a different air pres-sure drop you will be asked to re-calculate the fan too.
Configurator Components definition and calculation
inputs
Possibile selections
Calculate
Component currently under calculation
1. When the unit has been calcu-lated you can check his dimen-sions. Click on Dimensions Dimensions Dimensions but-ton.
2. The schematic drawing of the unit appears. The ahu is already split in more sections if the transport or manufacturing rules requires it. Anyway you can decide to split in a different way the unit or just add other divisions simply by clicking on the check boxes under the unit’s sketch. Press then ShowShowShow to see the result. Every split in-creases the length of the unit by 70 mm and also its price will be higher.
Configurator Ahu’s dimensions and splits
Split position
To show dimensions
1. When the unit has been calcu-lated you can select the proper casing. Click on Casing Casing Casing button.
2. On the casing window you can select.
?? Type of panel: always 50 mm thick but with different materials for the skins and the insulation
?? Roof
?? Technical room
?? Window and light at acces-sible sections
?? Enhanced thermal break ececution
?? Anodised aluminium pro-files (std is natural finish)
Configurator Casing definition
Panel type / material
To define the casing type
Paking type (std is loose)
Supply in assembled or disassembled form
Additional roof
Depth of the technical room ( =0 if not required )
Casing characteristics accordino to EN 1886