membrane characterization
DESCRIPTION
MEMBRANE TECHNOLOGY. MEMBRANE CHARACTERIZATION. ASEP MUHAMAD SAMSUDIN, S.T.,M.T. SCANNING ELECTRON MICROSCOPY (SEM). SEM is very simple and useful techniques for characterizing structure and morphology of membrane . - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/1.jpg)
MEMBRANE CHARACTERIZATION
ASEP MUHAMAD SAMSUDIN, S.T.,M.T.
MEMBRANETECHNOLOGY
![Page 2: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/2.jpg)
SCANNING ELECTRON MICROSCOPY (SEM)
• SEM is very simple and useful techniques for characterizing structure and morphology of membrane.
• A clear and concise picture of the membrane can be obtained in terms of the top layer, cross-section and bottom layer.
• Magnification in a SEM can be controlled from about 10 to 500,000 times
• The porosity and the pore size distribution can be estimated from the photographs.
• Care must be taken that the preparation techniques does not influence the actual porous structure.
Source : http://en.wikipedia.org
![Page 3: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/3.jpg)
SCANNING ELECTRON MICROSCOPY (SEM)
First Scanning Electron Microscope with high resolution from Manfred von Ardenne 1937 Source : www.ceo.msu.edu
Source : http://en.wikipedia.org
![Page 4: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/4.jpg)
SCANNING ELECTRON MICROSCOPY (SEM)
Flat Sheet Hollow Fiber
![Page 5: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/5.jpg)
PERMEABILITY• With this method, the pore size can be obtaining by measuring the flux through a
membrane at a constant pressure using the Hagen-Poiseuille equation• Hagen-Poiseuille equation
Retentate
Permeate
Feed
membrane
Cross-flow process
![Page 6: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/6.jpg)
PERMEABILITY
Dead-End process
Source : www.sciencedirect.com
![Page 7: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/7.jpg)
FOURIER TRANSFORM INFRARED SPECTROSCOPY
Source : www.ssi.shimadzu.com
• In membrane characterization, FTIR is used to determine the chemical composition of the membrane
• IR radiation is passed through a sample. Some of the infrared radiation is absorbed by the sample and some of it is passed through (transmitted)
• Infrared spectroscopy can result in a positive identification (qualitative analysis) of every different kind of material. In addition, the size of the peaks in the spectrum is a direct indication of the amount of material present.
• Fourier Transform Infrared (FT-IR) spectrometry was developed in order to overcome the limitations encountered with dispersive instruments.,
![Page 8: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/8.jpg)
FOURIER TRANSFORM INFRARED SPECTROSCOPY
400600800100012001400160018002000240028003200360040001/cm
0
0.2
0.4
0.6
0.8
1
1.2
1.4
Abs
3450
.65
3419
.79
3385
.07
2933
.73
2872
.01
2358
.94
1647
.21
1560
.41
1535
.34
1375
.25
1319
.31
1259
.52
1238
.30
1199
.72
1151
.50
1068
.56
1033
.85
898.
83
663.
51 617.
22
Kitosan Medium 2 gr Aktivasi GA 1%600750900105012001350150016501800195021002400270030003300360039001/cm
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
Abs
1575
.84
1558
.48
1487
.12
1294
.24
1242
.16
1151
.50
1105
.21
1047
.35
871.
8283
7.11
717.
5269
8.23
665.
44
626.
87
559.
36
518.
85
PES UF
![Page 9: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/9.jpg)
BUBBLE POINT METHOD• This method is a very simple technique for characterizing the largest pores
in microfiltration membrane.• The method essentially measure the pressure needed to blow air through
a liquid-filled membrane.• The top of the membrane is placed in contact with a liquid which fills all
the pores when the membrane is wetted. The bottom of membrane is in contact with air and as the air pressure is gradually increased bubbles of air penetrate through the membrane at a certain pressure.
• The relationship between pressure and pore radius is given by the Laplace equation.
• A disadvantages is that different results are obtained when different liquids are used for characterization.
![Page 10: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/10.jpg)
BUBBLE POINT METHOD
![Page 11: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/11.jpg)
SOLUTE REJECTION TEST (MWCO)• This method is very frequently used for the industrial assessment
membrane.• This method is often referred to as challenge test or sieving test.• In this method, permeability of solute (macromolecule) that used for
membrane test is measured in certain condition. • Membrane rejection was calculated using the equation
• Pore size is expressed by the molecular weight cut off which is defined as the molecular weight that 90% rejected by membrane.
![Page 12: MEMBRANE CHARACTERIZATION](https://reader036.vdocuments.net/reader036/viewer/2022062520/568165c1550346895dd8c825/html5/thumbnails/12.jpg)
SOLUTE REJECTION TEST (MWCO)
Solute BM
D-AlanineDL-PhenylananineTryptophanSucroseRaffinoseInulinPVP K15Dextran T10MyoglobinΑ-ChymotrypsinogenAlbuminAldolaseLgApoferitinlgM
8916520434259450001000010000178002450067000142000160000 480000960000