  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    1/8

    Customer: MxicoEL PEDREGAL

    Contact(s): J. Almazn, M. BelloDate: May 21rst, 2015ETI Contact(s): S. Stapleton, C. Paredes

    ubject : Findings from Service Courtesy Visit May 19thto 22nd2015.

    Visit Report

    Customer Info:ETI Project No: 98B001

    44x36 Live Bin

    6x84 Screw Feeder

    10x72 DCC Conditioner Cylinder

    7 Head LH E525A Extruder

    521 AFl Dryer 1 w/plastic mesh

    Customers Expectations:

    I.Have ETI techs do a thorough walkthrough around the plant, and hold a Wrap-Up meeting toaddress all the findings.

    II.Customer would like to improve current production rates on the E525 extrusion system. ETI toevaluate what must be done to achieve this important goal (Enhanced barrel configuration,additional drying sections, etc.)

    III.Customer would like to install a LIW and a Full Automated Control System on their existingE525 extrusion line.

    nformation Extru-Tech will need from El Pedregal

    Current Feed Rates when producing 0.6mm, 0.8mm, 1.0mm and 2.1mm pellets. What is the Amp Loads on the extruder main motor, when running 0.6mm, 0.8mm, 1.0mm and 2.1mm

    pellets.

    Current number of Holes in the 0.6mm, 0.8mm, 1.0mm, and 2.1mm Die Plates.

    What are the Drying Temperatures & % Moisture out of the Dryer for 0.6mm, 0.8mm, 1.0mm and2.1mm pellets.

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    2/8

    Plant Walkthrough & Findings

    Grinding, Mixing & Sifting

    Customer is adding liquids at the mixer & before sifting. NO liquids are being added at the Conditioner CylinderPossible problems: Plugged sifters, variations in the density of the meal in one same lot, before Extruders LiveBottom Bin, etc.

    10x72 DCC Conditioner Cylinder

    Steam pressure to the Conditioner found to be at 80psi.No AVT!DCC being rinsed every 4 months and NOT Once per weekBeater Configuration found to be Old standard and may be enhanced.

    E525A Extruder

    Found water inside Bearing Housing. Also found wrong type of oil has been used.Found old quill assembly with extensive level of wear. (See Pictures 1 & 2)Found extruder shaft worn extensively on Shoulder Section(See Picture 3)Found plugged vent in Bearing HousingFound locally made screws being used (See Picture 4)

    Found re-machine threads and cone bolt larger in diameterFound straight liners being installed. ETI currently is sending extruders with ALL spiral liners.Found new and worn knife blades were being used at the same time. When this is done, you

    have larger linear space between the knife cutting edges, and your product may haveinconsistent lengths. (See Picture 9)

    Extruder found running WITHOUT a Front End Shaft Support Assembly. (See Picture 5)Steam pressure to the Barrel found to be at 25psi.

    521 Dryer with MeshOld style of spout spreader chute was found. (See Picture 6 & 7)Air Filters on the Gas Burners were found plugged (very dirty with lots of dust) (See Picture 8) Plastic mesh was found very clean

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    3/8

    ncrease Current Production Rates (Kgs/Hr.)

    Install a larger DCC like a 16x72 model.Need to install new Bearing Housing, New Shaft, all new Screws and all new Liners

    Install a larger size extruder motor (from 125HP and go up to a maximum of 200HP)New Enhanced Proposed Extruder Barrel configurations (See Picture 10) Install two additional drying sections and one additional cooling section.Sign-Up for ETIs ESP program and provide an On-site Training course for all of your

    production, maintenance and QC teams.

    Automatic Control System with LIW (Loss In Weight)

    Increase the height of the Elevator Leg that fills the extruders Live Bottom Bin (need to confirmdimensions)

    Look into alternatives to re-locate your extruder, from where it is now.(See Picture 11, 12 & 13)

    Graphic Support

    Pictures 1 Pictures 2

    Pictures 3 Pictures 4 Pictures 5

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    4/8

    Pictures 6 Pictures 7

    Pictures 8 Pictures 9

    Pictures 10

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    5/8

    Pictures 11

    Pictures 12

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    6/8

    Pictures 13

    Pictures 14

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    7/8

    Pictures 15

    Pictures 16

  • 7/25/2019 MEXICO EL PEDREGAL Service Courtesy Visit MAY 19th to 22nd 2015

    8/8

    Pictures 17