Page 1: Micro Controller Based UPS

1

Microcontroller Based UPS

Project Supervisors:

Prof. Azhar Hussain Shah

Project Team:

Jamshaid Minhas L2F06BSEE0444

Ammar Ilyas Butt L2F06BSEE0449

M. Farooq Adil L2F06BSEE0451

SESSION 2006

FACULTY OF ENGINEERING

UNIVERSITY OF CENTRAL PUNJAB

LAHORE, PAKISTAN

Page 2: Micro Controller Based UPS

2

Microcontroller Based UPS

This project report is submitted to the Faculty of Engineering, University of Central Punjab,

Lahore, Pakistan for the partial fulfillment of requirements for the degree

Of

Bachelor of Science

In

Electrical Engineering

---------------------

Internal Examiner: Sign: _____________________________

Name: ____________________________

External Examiner: Sign: ______________________________

Name: _____________________________

SESSION 2006

FACULTY OF ENGINEERING

UNIVERSITY OF CENTRAL PUNJAB

LAHORE, PAKISTAN

Page 3: Micro Controller Based UPS

3

Acknowledgement

We would like to thank Allah, the Almighty at the first place for giving us much

courage and strength during the completion of this project and thesis, without the

help of Whom all His creatures are worthless .

Several people should also be mentioned for their contributions to accomplish our

task. We are greatful to our project supervisor Prof Azhar Hussain Shah for his

kind supervision, help and support. We are also thankful to the lab staff in the

Project Lab for their cooperation during this work

Page 4: Micro Controller Based UPS

4

Contents

Page No.

Introduction 4-19

Chapter 1

Components of UPS

1.1 DC/DC Converter 20

1.1.1 Forward Converter 21

1.1.2 Push-Pull Converter 21

1.1.3 Half-Bridge Converter 23

1.1.4 Full-Bridge Converter 24

1.1.5 Flyback Converter 25

1.2 VOLTAGE SOURCE INVERTER (VSI) 26

1.2.1 Half-Bridge VSI 26

1.2.2 Full-Bridge VSI 27

1.3 BATTERY CHARGER 28

1.3.1 Linear Chargers 28

1.3.2 Switch Mode Chargers 29

1.3.3 Ferroresonant Chargers 29

1.3.4 SCR Chargers 30

Chapter 2

Hardware Overview

2.1 Principles and configurations 31

2.2 Design criteria and selection 31

2.3 Selecting an UPS 32

2.4 INVERTER 33

2.5 Modified sine wave 34

Page 5: Micro Controller Based UPS

5

2.6 Pulse Width Modulation 35

2.7 Block Diagram: 36

Chapter 3

Software

3.1 Introduction 37

3.2 Software Listing 37-57

3.3 Software Flowchart 58

Chapter 4

System operation

4.1 Introduction 59

4.2 LED status 60

4.3 Transformer 60

4.4 Feedback 60

4.5 Other components 61

4.6 Ups conversion 62

4.7 Output wave form 63

4.8 Problem encounter 63

4.9 PCB and assembly 64

Recommendations and Refrences 69

Appendix A 70-71

Appendix B 72-73

Appendix C 74-75

Appendix D 76-77

Appendix E 78-79

Appendix F 80-82

Page 6: Micro Controller Based UPS

6

Introduction

An Uninterruptible power supply (UPS), also known as a battery back-up, provides emergency

power and, depending on the topology, line regulation as well to connected equipment by

supplying power from a separate source when utility power is not available. It differs from an

auxiliary or emergency power system or standby generator, which does not provide instant

protection from a momentary power interruption. A UPS, however, can be used to provide

uninterrupted power to equipment, typically for 5–15 minutes until an auxiliary power supply

can be turned on, utility power restored, or equipment safely shut down. While not limited to

safeguarding any particular type of equipment, a UPS is typically used to protect computers, data

centers, telecommunication equipment or other electrical equipment where an unexpected power

disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units

come in sizes ranging from units which will back up a single computer without monitor (around

200 VA) to units which will power entire data centers, buildings, or even an entire city. (several

megawatts).

An UPS contains an internal rechargeable battery that gets charged from the power

line then gets used to generate line power to the load when the power line fails. To accomplish

that they also contain an inverter, an electronic device capable of generating 110/220v AC from

battery-level DC voltage. There are different types of UPS depending on how and when the

power generation occurs, and how precisely sine waveshaped AC voltage they produce. Power

line AC voltage is supposed to be a sine-wave, and it mostly is. UPS-generated AC is usually a

lot less sine-shaped and some devices care more about than that others.

For large power units, Dynamic Uninterruptible Power Supply are sometimes

used. A synchronous motor/alternator is connected on the mains via a choke. Energy is stored in

a flywheel. When the mains power fails, an Eddy-current regulation maintains the power on the

load. DUPS are sometimes combined or integrated with a dieselgenerator, forming a diesel

rotary uninterruptible power supply, or DRUPS.

Generally, an ideal UPS should be able to deliver uninterrupted power while

simultaneously providing the necessary power conditioning for the particular power application.

Therefore, an ideal UPS should have the following features

● Regulated sinusoidal output voltage with low total harmonic distortion (THD) independent of

the changes in the input voltage or in the load, linear or nonlinear, balanced or unbalanced.

Page 7: Micro Controller Based UPS

7

● On-line operation, which means zero switching time from normal to backup mode and vice

versa.

● Low THD sinusoidal input current and unity power factor.

● High reliability.

● Bypass as a redundant source of power in the case of internal

failure.

● High efficiency.

● Low electromagnetic interference (EMI) and acoustic noise.

● Electric isolation of the battery, output, and input.

● Low maintenance.

● Low cost, weight, and size.

The Need for Standby Generation:

The need for standby generation arises if the consequences of a failure or disruption of the

normal supply are not acceptable. The types of installation in which the need arises seem to be

limitless. There are basically four reasons for installing standby generation: safety, security,

financial loss and data loss.

Page 8: Micro Controller Based UPS

8

Safety Where there is a risk to life or health such as in air traffic control, aviation ground

lighting, medical equipment in hospitals, nuclear installations, oil refineries.

Security against vandalism, espionage, or attack Area lighting, communication systems,

military installations, etc.

Data loss Situations in which the loss of data may be catastrophic and irretrievable such as data

processing and long-term laboratory type of testing or experiment

Financial loss Critical industrial processes, large financial institutions, etc.

The advances in power electronics during the past three decades have resulted in a

great variety of new topologies and control strategies for UPS systems. The research has been

focused mainly on improving performance and expanding application areas of UPS systems. The

issue of reducing the cost of converters has recently attracted the attention of researcher.

Reducing the number of switches provides the most significant cost reduction. Another form of

cost reduction is to replace active switches such as IGBTs, MOSFETs, and thyristors with

diodes. Not only are diodes more reasonable than the controlled switches, but there is also a cost

reduction from eliminating gate drivers for active switches and power supplies for gate drivers.

Another way of reducing cost is to develop topologies that employ switches with lower reverse

voltage stresses and lower current ratings, which means less silicon and smaller switching losses

resulting in lower cost and higher efficiency.

Classification:

UPS systems are classified into three general types: static, rotary, and hybrid static/rotary. In this

section, we explain these three categories of the UPS systems.

On-Line UPS:

On-line UPS systems appeared during the 1970s. They consist of a rectifier/ charger, a battery

set, an inverter, and a static switch (bypass). Other names for this configuration are inverter-

preferred UPS and double-conversion UPS Figure 1 shows the block diagram of a typical on-line

UPS. The rectifier/charger continuously supplies the DC bus with power. Its power rating is

required to meet 100% of the power demanded by the load as well as the power demanded for

Page 9: Micro Controller Based UPS

9

charging the battery bank. The batteries are usually sealed lead–acid type. They are rated in order

to supply power during the backup time, when the AC line is not available. The duration of this

time varies in different applications. The inverter is rated at 100% of the load power since it must

supply the load during the normal mode of operation as well as during the backup time. It is

always on; hence, there is no transfer time associated with the transition from normal mode to

stored energy mode.This is the main advantage of the on-line UPS systems. The static switch

provides redundancy of the power source in the case of UPS malfunction or overloading. The

AC line and load voltage must be in phase in order to use the static switch. This can be achieved

easily by locked-phase control loop.

Figure 1: On-Line UPS

There are three operating modes related to this topology: normal mode, stored energy mode, and

bypass mode.

Normal Mode of Operation:

During this mode of operation, the power to the load is continuously supplied via the

rectifier/charger and inverter. In fact, a double conversion, that is, AC/DC and DC/AC, takes

place. It allows very good line conditioning. The AC/DC converter charges the battery set and

supplies power to the load via the inverter. Therefore, it has the highest power rating in this

topology, increasing the cost.

Stored-Energy Mode of Operation:

When the AC input voltage is outside the preset tolerance, the inverter and battery maintain

continuity of power to the load. The duration of this mode is the duration of the preset UPS

Page 10: Micro Controller Based UPS

10

backup time or until the AC line returns within the preset tolerance. When the AC line returns, a

phase-locked loop (PLL) makes the load voltage in phase with the input voltage and after that the

UPS system returns to the normal operating mode.

Bypass Mode of Operation:

The UPS operates in this mode in case of an internal malfunction such as over current. This

mode is also used for fault clearing. It should be mentioned that the output frequency should be

the same as the AC line frequency in order to ensure the transfer of power. In some cases, there

can be a maintenance bypass as well. A manual switch usually operates it.

The main advantages of on-line UPS are very wide tolerance to the input

voltage variation and very precise regulation of output voltage. In addition, there is no transfer

time during the transition from normal to stored energy mode. It is also possible to regulate or

change the output frequency.

The main disadvantages of this topology are low-power factor, high THD at the

input, and low efficiency. The input current is distorted by the rectifier unless an extra power

factor correction (PFC) circuit is added; but, this adds to the cost of the UPS system. Because of

this inherently low input power factor, the on-line UPS cannot efficiently utilize the utility

network and local installation. The low efficiency is inherent to this topology because of the

double-conversion nature of this UPS. Power flow through the rectifier and inverter during the

normal operation means higher power losses and lower efficiency compared to off-line and line-

interactive UPS systems.

Despite the disadvantages, double-conversion UPS is the most preferred

topology in performance, power conditioning, and load protection. This is the reason why they

have a very broad range of applications from a few kVA to several MVA. This broad range of

applications brings a large diversity of topologies in on-line UPS systems. Each topology tries to

solve different specific problems and the particular choice depends upon the particular

application. However, generally, there are two major types of double-conversion topologies: with

a low-frequency transformer isolation and with a highfrequency transformer isolation.Figure 2

shows the block diagram of an online UPS with a low-frequency transformer isolation at the

output.

Page 11: Micro Controller Based UPS

11

Figure 2: Block diagram of an on-line UPS with a low-frequency transformer isolation at the output.

In this configuration, there is an isolating transformer at the output, which

operates at low frequency. This, of course, means a larger transformer. Therefore, this topology

is used only in high-power ratings (_20 kVA), where the switching frequency is limited to less

than 2 kHz. Apart from the large size of the isolating transformer, the drawback of this topology

is high acoustic noise from the transformer as well as the reactor of the output filter. This

topology also has a poor transient response to the changes in the load and input voltage.

By increasing the switching frequency of the inverter above 20 kHz, these

problems are solved, except for the size of the isolating transformer, since it is independent of the

switching frequency. A topology employing a high frequency transformer link can significantly

reduce the weight and the size of the transformer. The use of high-frequency pulse width

modulation (PWM) techniques can additionally reduce the size of the output filter. Figure 3

shows the block diagram of an on-line UPS with a high-frequency transformer isolation between

the input and the output.

Page 12: Micro Controller Based UPS

12

Figure 3: Block diagram of an on-line UPS with high-frequency transformer isolation.

Off-Line UPS:

This configuration is also known as the standby UPS or line-preferred UPS. As shown in Figure

4, it consists of an AC/DC converter, a battery bank, a DC/AC inverter, and a static switch.

Afilter may be used at the output of the UPS or inverter to improve the quality of the output

voltage. The static switch is on during the normal mode of operation when the AC line is alive.

Therefore, the load is supplied with power from the AC line directly without any

power conditioning. The AC/DC converter charges the battery set. It is rated at a much lower

power rating than the rectifier/charger in an on-line UPS since it is not required to meet the

power demand of the load. This, in turn, makes the off-line UPS systems more reasonable than

the on-line UPS systems. The inverter is rated at 100% of the load’s demand. It is connected in

parallel to the load and stays standby during the normal mode of operation. It is turned on only

when the primary power is out of a given preset tolerance or is not available at all. During this

mode of operation, the power to the load is supplied by the battery set via the inverter for the

duration of the preset backup time or until the AC line is back again. The duration of the

switching time depends on the starting time of the inverter. The transfer time is usually about ¼

line cycle, which is enough for most of the applications such as personal computers.

Page 13: Micro Controller Based UPS

13

Figure 4: OFF-Line UPS

The DC/AC inverter is conventionally off in this mode. Therefore, an offline UPS

is not usually correcting the power factor. However, in the normal mode of operation, the

DC/AC inverter may be used as an active filter to reduce the harmonic content of the line current

or improve the power factor of the load. Further modification can also be made to reduce the

harmonic content of the sinking current by the AC/DC converter when charging the battery. Yet,

these increase the complexity of the system.

There are two operating modes for an off-line UPS system: normal mode and

stored-energy mode.

Normal Mode of Operation:

In this mode, the AC line supplies the load via filter/conditioner, which, in fact, is not always

required, but often exists. The filter/conditioner depends on the requirements of the particular

load and the quality of the AC line power supply. The AC/DC converter charges the battery in

this mode in order to provide backup power for the stored-energy mode of operation.

Stored-Energy Mode of Operation:

When the AC line is beyond the preset tolerance or is not available, the load is supplied by the

battery set through the inverter for the backup time or until the AC line is available again. The

rating of the AC/DC converter has to meet only the charging requirements of the battery, which

contributes to the lower cost of this UPS.

Page 14: Micro Controller Based UPS

14

The main advantages of this topology are a simple design, low cost, and small

size. The line conditioning, when there is such a feature, is passive and the technique is very

robust. On the other hand, lack of real isolation of the load from the AC line, no output voltage

regulation, long switching time, and poor performance with nonlinear loads are the main

disadvantages.

The use of a three-winding transformer, as shown in Figure 5, can provide electric

isolation for the off-line UPS. This technique has a high reliability at a moderate cost. The

transformer allows limited power conditioning for the output voltage as well. The use of a Ferro-

resonant transformer leads to a heavier UPS with a lower efficiency. The disadvantages of off-

line UPS systems limit their application to less than 2 kVA.

Figure 5: Block diagram of a typical off-line UPS using a three-winding transformer for electric isolation.

Line-Interactive UPS:

In the 1990s, line-interactive UPS systems were presented. As shown in Figure 6, a line-

interactive UPS system consists of a static switch, a series inductor, a bidirectional converter,

and a battery set.

Page 15: Micro Controller Based UPS

15

Figure 6: Block diagram of a typical line-interactive UPS system.

A line-interactive UPS system can operate either as an on-line UPS or as an off-

line UPS. For an off-line line-interactive UPS, the series inductor is not required. However, most

of the line-interactive UPS systems operate on-line in order to either improve the power factor of

the load or regulate the output voltage for the load.

Figure 7: Line-Interactive UPS, Typical protection time: 5 - 30 minutes, Capacity expansion: Several hours

Page 16: Micro Controller Based UPS

16

When the AC line is within the preset tolerance, it feeds the load directly. The

inverter is connected in parallel with the load and charges the battery. It may also supply the

reactive power required to keep the power factor close to unity or to regulate the output voltage.

Rotary UPS:

Atypical rotary UPS is shown in Figure 8. It consists of an AC motor, a DC machine, an AC

generator, and a battery bank. Electric machines are mechanically coupled. There are two

operating modes: normal and stored energy. During the normal mode of operation, the AC line

supplies the AC motor, which drives the DC machine. The DC machine drives the AC generator,

which supplies the load. During the stored energy mode of operation, the battery bank supplies

the DC machine, which in turn drives the AC generator. The AC generator supplies the load.

Figure 8: Block diagram of a typical rotary UPS system.

The rotary UPS systems are more reliable than the static UPS systems. However,

they require more maintenance and have a much larger size and weight. But, they have many

advantages making them desirable in high power applications. One of the advantages of the

rotary UPS systems is that the transient overload capability is 300 to 600% of the full load for

Page 17: Micro Controller Based UPS

17

rapid fault clearing. The transient overload capability for the static UPS systems is typically

150% for a short term. The performance of the rotary UPS systems with nonlinear loads is good

because of the low output impedance. The input current THD is very low, typically 3% or less.

The electromagnetic interference (EMI) is also low. The efficiency is usually 85% or higher.

Hybrid Static/Rotary UPS:

Hybrid static/rotary UPS systems combine the main features of both static and rotary UPS

systems. They have low output impedance, high reliability, excellent frequency stability, and low

maintenance cost. These are because of the missing mechanical commutator . In Figure 9, a

typical hybrid static/rotary UPS is depicted. It consists of a bidirectional AC/DC converter, an

AC motor, an AC generator, a battery bank, and a static switch.

Figure 9: Block diagram of a typical hybrid static/rotary UPS.

During the normal mode of operation, the AC motor is fed from the AC line and

drives the generator. The AC generator supplies the load. The bidirectional converter, which

behaves as a rectifier, charges the battery.

Page 18: Micro Controller Based UPS

18

During the stored-energy mode of operation, the inverter supplies the AC

generator from the battery set through the AC motor. In fact, the bidirectional converter, which

behaves as an inverter, drives the AC motor. The AC motor drives the generator supplying the

load. When an internal malfunction in the UPS system occurs, the static switch (bypass) is turned

on and the load is supplied directly from the AC line. However, since the AC line and output

voltage are not synchronized, the transition is not transient-free.

The AC generator is started on utility power to avoid starting current overloads

allowing the inverter to be rated for the normal operation. After the AC generator is on, the AC

line is disconnected and the supply to the AC generator is given by the inverter. It is relatively

easy because of the large inertia of the AC generator. This configuration has the advantage that

the transfer from the AC line to the inverter takes place under controlled conditions instead of

under fault conditions when different undesired conditions can influence the transfer. Another

good point is that the inverter is always on, allowing no transfer time for switching to the stored-

energy mode of operation.

The main advantages of this UPS over the static UPS include low output

impedance, low THD with nonlinear loads, higher reliability, and better isolation. Hybrid UPS

systems are usually used in very high-power applications, that is, several hundreds kVA.

DESIGN BACKGROUND:

When designing a UPS system, there are three items that must be considered: cost vs.

performance, output waveform and topology.

Cost vs. Performance:

A UPS system has to be reliable. Money saved on features or performance can be overshadowed

by the cost associated with data loss or component failure. So it is important to develop a cost

effective solution which satisfies both end user price sensitivity and design robustness.

Output Waveform:

Some UPS designs use a square wave output instead of a sine wave. This makes the system

cheaper to produce. But is this type of waveform really acceptable?

Page 19: Micro Controller Based UPS

19

Electrical equipment uses power delivered in the form of a sine wave from local

utility companies. When considering alternative waveforms, how differing loads rely on different

parts of the standard power company waveform must be examined.

For instance, most appliances are always on, thus the power used by the appliance

is the RMS value of the sine wave, which is approximately 120 volts. However, equipment such

as computers use peak voltage values, which are approximately 170 volts. When a square wave

output is used to supply power to computer equipment, the RMS and peak values are equivalent,

thus stressing some loads and under-supplying others. So the best output to provide electrical

equipment is the output that they are designed to operate with - a sine wave.

Application Markets for UPS Systems:

UPS systems provide for a large number of applications in a variety of industries. Their common

applications range from small power rating for personal computer systems to medium power

rating for medical facilities, life-support systems, data storage, and emergency equipment, and

high power rating for telecommunications, industrial processing, and online management

systems. Different considerations should be taken into account for these applications. As an

example, a UPS for emergency systems and lighting may support the system for 90-120 minutes.

For other applications like computer backup power, a UPS may typically support the system for

15-20 minutes. If power is not restored during that time, the system will be gracefully shut down.

If a longer backup period is considered, a larger battery is required. For process

equipment and high power applications, some UPS systems are designed to provide enough time

for the secondary power sources, such as diesel generators, to start up.

Page 20: Micro Controller Based UPS

20

Chapter 1

COMPONENTS OF UPS

Mainly UPS consists of

DC/DC CONVERTER

VOLTAGE SOURCE INVERTER (VSI)

BATTERY CHARGER

1.1 DC/DC Converters:

Most UPS designs contain a transformer-type DC/DC converter. The transformer provides

electrical isolation between the input and output of the converter. The transformer also provides

the option to produce multiple voltage levels by changing the turns ratio, or provide multiple

voltages by using multiple secondary windings.

Transformer-type DC/DC converters are divided into five basic topologies:

• Forward Converter

• Push-Pull Converter

• Half-Bridge Converter

• Full-Bridge Converter

• Flyback Converter

The Flyback topology operation differs slightly from other topologies in that energy is

stored in magnetic material and then released. Other topologies always transfer energy directly

from input to output. Another case in which topologies are distinguished from each other is

transformer core utilization:

Selection of a topology depends on careful analysis of the design specifications, cost and

size requirements of the converter. Operation of each of the above topologies is described in the

following sections of this application note. Details of the topology selection and hardware design

are provided in subsequent sections.

Page 21: Micro Controller Based UPS

21

1.1.1 Forward Converter:

A forward converter, which can be a step-up or stepdown converter, is shown in Figure 1.1.

When the transistor Q is ON, VIN appears across the primary, and then generates output voltage

determined by Equation 1.

The diode D1 on the secondary ensures that only positive voltages are applied to the output

circuit while D2 provides a circulating path for inductor current if the transformer voltage is zero

or negative. A third winding is added to the transformer of a forward converter, also known as a

―reset winding‖. This winding ensures that the magnetization of the transformer core is reset to

zero at the start of the switch conduction. This winding prevents saturation of the transformer.

Figure 1.1: FORWARD CONVERTER

1.1.2 Push-Pull Converter:

A push-pull converter is shown in Figure 1.2. When Q1 switches ON, current flows through the

upper half of the T1 transformer primary and the magnetic field in T1 expands. The expanding

magnetic field in T1 induces a voltage across the T1 secondary; the polarity is such that D2 is

forward-biased and D1 is reverse-biased. D2 conducts and charges the output capacitor C2 via

L1. L1 and C2 form an LC filter network. When Q1 turns OFF, the magnetic field in T1

Page 22: Micro Controller Based UPS

22

collapses and after a period of dead time (dependent on the duty cycle of the PWM drive signal),

Q2 conducts, current flows through the lower half of T1's primary, and the magnetic field in T1

expands. At this point, the direction of the magnetic flux is opposite to that produced when Q1

conducted. The expanding magnetic field induces a voltage across the T1 secondary; the polarity

is such that D1 is forward- biased and D2 is reverse-biased. D1 conducts and charges the output

capacitor C2 via L1. After a period of dead time, Q1 conducts and the cycle repeats.

Figure 1.2: PUSH-PULL CONVERTER

There are two important considerations with the push-pull converter:

Both transistors must not conduct together, as this would effectively short circuit the supply.

This means that the conduction time of each transistor must not exceed half of the total

period (d < 0.5) for one complete cycle, otherwise conduction will overlap.

The magnetic behavior of the circuit must be uniform; otherwise, the transformer may

saturate, and this would cause destruction of Q1 and Q2. This behavior requires that the

individual conduction times of Q1 and Q2 must be exactly equal and the two halves of the

center-tapped transformer primary must be magnetically identical.

These criteria must be satisfied by the control and drive circuit and the transformer. The

output voltage equals that of Equation 2.

Page 23: Micro Controller Based UPS

23

1.1.3 Half-Bridge Converter:

The half-bridge converter (see Figure 1.3) is similar to the push-pull converter, but a center-

tapped primary is not required. The reversal of the magnetic field is achieved by reversing the

direction of the primary winding current flow. In this case, two capacitors. C1 and C2, are

required to form the DC input mid-point. Transistors Q1 and Q2 are turned ON alternately to

avoid a supply short circuit, in which case the duty cycle, d, must be less than 0.5.

For the half-bridge converter, the output voltage VOUT equals that of Equation 3.

Page 24: Micro Controller Based UPS

24

Figure 1.3: HALF-BRIDGE CONVERTER

1.1.4 Full-Bridge Converter:

The full-bridge converter topology shown in Figure 1.4, is basically the same as the half-bridge

converter, where four transistors are used. Diagonal pairs of transistors (Q1-Q4 or Q2-Q3)

conduct alternately, thus achieving current reversal in the transformer primary. Output voltage

equals that of Equation 4.

Page 25: Micro Controller Based UPS

25

Figure 1.4: FULL-BRIDGE CONVERTER

1.1.5 Flyback Converter:

Figure 1.5 shows a flyback converter circuit. When transistor Q1 is ON, due to the winding

polarities, the diode D1 becomes reverse-biased. Therefore, transformer core flux increases

linearly. When transistor Q1 is turned OFF, energy stored in the core causes the current to flow

in the secondary winding through the diode D1 and flux decreases linearly. Output voltage is

given by Equation 5.

Page 26: Micro Controller Based UPS

26

Figure 1.5: FLYBACK CONVERTER

1.2 VOLTAGE SOURCE INVERTER (VSI):

A single-phase Voltage Source Inverter (VSI) can be defined as a half-bridge and a full-bridge

topology. Both topologies are widely used in power supplies and single-phase UPS systems.

1.2.1 Half-Bridge VSI:

Figure 1.6 shows the topology of a Half-Bridge VSI, where two large capacitors are required to

provide a neutral point N, such that each capacitor maintains a constant voltage vi 2. Because

the current harmonics injected by the operation of the inverter are low-order harmonics, a set of

large capacitors (C+ and C-) is required. The duty cycle of the switches is used to modulate the

output voltage. The signals driving the switches must ensure some dead time to prevent shorting

of the DC bus.

Page 27: Micro Controller Based UPS

27

Figure 1.6: SINGLE-PHASE HALF-BRIDGE VSI

1.2.2 Full-Bridge VSI:

Figure 1.7 shows the topology of a Full-Bridge VSI. This inverter is similar to the half-bridge

inverter; however, a second leg provides the neutral point to the load. Both switches S1+ and S1-

(or S2+ and S2-) cannot be on simultaneously because a short circuit across the DC link voltage

source vi would be produced. To avoid the short circuit across the DC bus and the undefined AC

output voltage condition, the modulating technique should ensure that either the top or the

bottom switch of each leg is ON at any instant. The AC output voltage can take values up to the

DC link value vi, which is twice the value obtained with half-bridge VSI topologies. Several

modulating techniques have been developed that are applicable to full-bridge VSIs. Among

them, the best known are bipolar and unipolar PWM techniques.

Figure 1.7: SINGLE-PHASE FULL-BRIDGE VSI

Page 28: Micro Controller Based UPS

28

1.3 BATTERY CHARGER:

When the AC mains voltage is present, the Offline UPS charges the batteries, and therefore, a

battery charger circuit is implemented.

Most battery chargers can be divided into four basic design types, or topologies:

• Linear Chargers

• Switch Mode Chargers

• Ferroresonant Chargers

• SCR Chargers

1.3.1 Linear Chargers:

Linear chargers consist of a power supply, which converts AC power to lower voltage DC

power, and a linear regulating element, which limits the current that flows into the battery. The

power supply typically consists of a transformer that steps down AC power from 220/110 VAC

to a lower AC voltage closer to that of the battery, and a rectifier that smooths out the existing

sinusoidal AC signal into a constant-voltage DC signal. The linear regulating element may be a

passive component such as a resistor or an active component such as a transistor that is

controlled by a reference signal. Figure 1.8 shows a simplified schematic of a linear charger with

a linear power supply with a resistor as the current regulating element.

Figure 1.8: LINEAR CHARGER

Page 29: Micro Controller Based UPS

29

1.3.2 Switch Mode Chargers:

In a switch mode charger, AC voltage is rectified, and then converted to a lower DC voltage

through a DC/DC converter. This type of charger contains additional charge control circuitry to

regulate current flow into the battery. The charge control regulates the way in which the power

switch turns ON and OFF, and may be accomplished through a circuit, a specialized integrated

chip, or some type of software control. A simplified schematic for a single piece switch mode

charger is shown in Figure 1.9.

Figure 1.9: SWITCH MODE CHARGER

1.3.3 Ferroresonant Chargers:

Ferroresonant chargers (sometimes called ferro chargers), operate by way of a special component

called a ferroresonant transformer. The ferroresonant transformer reduces the AC voltage to a

lower regulated voltage level while simultaneously controlling the charge current. A rectifier

then converts the AC power to DC power suitable for the battery. Figure 1.10 shows a block

diagram of a ferroresonant charger.

Page 30: Micro Controller Based UPS

30

Figure 1.10: FERRORESONANT CHARGER

1.3.4 SCR Chargers:

SCR chargers use a special component known as a Silicon-Controlled Rectifier (SCR) to control

the current to the battery. The SCR is a controllable switch that can be turned ON and OFF

multiple times per second. After a transformer reduces utility voltage to a value near that of the

battery, the diodes rectify the current while the SCR enables the flow of charge current according

to a control signal. A block diagram of an SCR charger is shown in Figure 1.11.

Figure 1.11: SCR CHARGER

Page 31: Micro Controller Based UPS

31

Chapter 2

Hardware Overview

2.1 Principles and configurations

An UPS system is an alternate or backup source of power with the electric utility company being

the primary source. The UPS provides protection of load against line frequency variations,

elimination of power line noise and voltage transients, voltage regulation, and uninterruptible

power for critical loads during failures of normal utility source. An UPS can be considered a

source of standby power or emergency power depending on the nature of the critical loads. The

amount of power that the UPS must supply also depends on these specific needs. These needs

can include emergency lighting for evacuation, emergency perimeter lighting for security,

orderly shut down of manufacturing or computer operations, continued operation of life support

or critical medical equipment, safe operation of equipment during sags and brownouts, and a

combination of the preceding needs.

2.2 Design criteria and selection

The UPS selection process involves several steps as discussed briefly here. These steps are

discussed in further detail in chapter 3.

a. Determine need. Prior to selecting the UPS it is necessary to determine the need. The

types of loads may determine whether local, state, or federal laws mandate the

incorporation of an UPS. An UPS may be needed for a variety of purposes such as

lighting, startup power, transportation, mechanical utility systems, heating, refrigeration,

production, fire protection, space conditioning, data processing, communication, life

support, or signal circuits. Some facilities need an UPS for more than one purpose. It is

important to determine the acceptable delay between loss of primary power and

availability of UPS power, the length of time that emergency or backup power is

required, and the criticality of the load that the UPS must bear. All of these factors play

into the sizing of the UPS and the selection of the type of the UPS.

b. Determine safety. It must be determined if the safety of the selected UPS is

acceptable. The UPS may have safety issues such as hydrogen accumulation from

batteries, or noise pollution from solid-state equipment or rotating equipment. These

issues may be addressed through proper precautions or may require a selection of a

different UPS.

Page 32: Micro Controller Based UPS

32

c. Determine availability. The availability of the selected UPS must be acceptable. The

criticality of the loads will determine the necessary availability of the UPS. The

availability of an UPS may be improved by using different configurations to provide

redundancy. It should be noted that the C4ISR facilities require a reliability level of

99.9999 percent.

d. Determine maintainability. The selected UPS must be maintainable. Maintenance of

the unit is important in assuring the unit’s availability. If the unit is not properly cared

for, the unit will be more likely to fail. Therefore, it is necessary that the maintenance be

performed as required. If the skills and resources required for the maintenance of the unit

are not available, it may be necessary to select a unit requiring less maintenance.

e. Determine if affordable. The selected UPS must be affordable. While this is the most

limiting factor in the selection process, cost cannot be identified without knowing the

other parameters. The pricing of the unit consists of the equipment cost as well as the

operating and maintenance costs. Disposal costs of the unit should also be considered for

when the unit reaches the end of its life.

f. Re-evaluate steps. If these criteria are not met, another UPS system must be selected

and these steps re-evaluated.

2.3 Selecting an UPS

The process for selecting an UPS consists of eight steps. These steps are: determining the need

for an UPS, determining the purpose(s) of the UPS, determining the power requirements,

selecting the type of UPS, determining if the safety of the selected UPS is acceptable,

determining if the availability of the selected UPS is acceptable, determining if the selected UPS

is maintainable, and determining if the selected UPS is affordable. The last four steps may

require repeating if the UPS does not meet all of the requirements. This process does not and

cannot provide a ―cookbook solution.‖ Each facility has unique requirements for emergency and

standby power. These requirements include the reliability of the prime power source, the nature

of the work done, local and state regulations governing emergency power, etc.

The process does not give a single solution that is applicable to all cases. It is hoped,

however, that it provides the framework for selecting an UPS for any facility. Figure 3-1

illustrates this process. To help illustrate how the selection procedure can be used, an example is

provided in appendix B. This example is completely fictitious and should not be considered as

―the‖ model for how the selection process would be used in every case. It does, however,

illustrate the many factors that go into the decision process and the need for a good staff to assist

the facility manager in making the UPS selection.

Page 33: Micro Controller Based UPS

33

2.4 INVERTER

The method in which the low voltage DC power is inverted, is completed in two steps. The first

being the conversion of the low voltage DC power to a high voltage DC source, and the second

step being the conversion of the high DC source to an AC waveform using pulse width

modulation. Another method to complete the desired outcome would be to first convert the low

voltage DC power to AC, and then use a transformer to boost the voltage to 120 volts. This

project focused on the first method described and specifically the transformation of a high

voltage DC source into an AC output.Of the different DCAC inverters on the market today there

are essentially two different forms of AC output generated: modified sine wave, and pure sine

wave1.

A modified sine wave can be seen as more of a square wave than a sine wave; it passes

the high DC voltage for specified amounts of time so that the average power and rms voltage are

the same as if it were a sine wave. These types of inverters are much cheaper than pure sine wave

inverters and therefore are attractive alternatives. Pure sine wave inverters, on the other hand,

produce a sine wave output identical to the power coming out of an electrical outlet. These

devices are able to run more sensitive devices that a modified sine wave may cause damage to

such as: laser printers, laptop computers, power tools, digital clocks and medical equipment. This

form of AC power also reduces audible noise in devices such as fluorescent lights and runs

inductive loads, like motors, faster and quieter due to the low harmonic distortion.

Page 34: Micro Controller Based UPS

34

2.5 Modified sine wave

Figure 2.2: Modified sine wave

A modified sine wave is similar to a square wave but instead has a ―stepping‖ look to it that

relates more in shape to a sine wave. This can be seen in Figure 2, which displays how a

modified sine wave tries to emulate the sine wave itself. The waveform is easy to produce

because it is just the product of switching between 3 values at set frequencies, thereby leaving

out the more complicated circuitry needed for a pure sine wave. The modified sine wave inverter

provides a cheap and easy solution to powering devices that need AC power. It does have some

drawbacks as not all devices work properly on a modified sine wave, products such as computers

and medical equipment are not resistant to the distortion of the signal and must be run off of a

pure sine wave power source.

Page 35: Micro Controller Based UPS

35

2.6 Pulse Width Modulation

In electronic power converters and motors, PWM is used extensively as a means of powering

alternating current (AC) devices with an available direct current (DC) source or for advanced

DC/AC conversion. Variation of duty cycle in the PWM signal to provide a DC voltage across

the load in a specific pattern will appear to the load as an AC signal, or can control the speed of

motors that would otherwise run only at full speed or off. This is further explained in this

section. The pattern at which the duty cycle of a PWM signal varies can be created through

simple analog components, a digital microcontroller, or specific PWM integrated circuits.

Analog PWM control requires the generation of both reference and carrier signals that feed into a

comparator which creates output signals based on the difference between the signals10. The

reference signal is sinusoidal and at the frequency of the desired output signal, while the carrier

signal is often either a sawtooth or triangular wave at a frequency significantly greater than the

reference. When the carrier signal exceeds the reference, the comparator output signal is at one

state, and when the reference is at a higher voltage, the output is at its second state. This process

is shown in Figure 3 with the triangular carrier wave in red, sinusoidal reference wave in blue,

and modulated and unmodulated sine pulses.

Figure 2.3: Pulse width Modulation

Page 36: Micro Controller Based UPS

36

In order to source an output with a PWM signal, transistor or other switching technologies are

used to connect the source to the load when the signal is high or low. Full or half bridge

configurations are common switching schemes used in power electronics. Full bridge

configurations require the use of four switching devices and are often referred to as Hbridges due

to their orientation with respect to a load.

2.7 Block Diagram:

Block Diagram of Harare is shown below.

PWM

Pre-Driver Circuit

PIC16F876A

Driver Circuit

4 7’

Comparator

H-Bridge LC Filter

Current

Sense

Voltage

Sense

Enable

A/B

Output

4 7’ 9 12’

Page 37: Micro Controller Based UPS

37

Chapter 3

Software

3.1 Introduction

Why use C?

The C language was developed at Bell Labs in the early 1970’s by Dennis Ritchie and Brian

Kernighan. One of the first platforms for implementation was the PDP-11 running under a UNIX

environment. Since its introduction, it has evolved and been standardized throughout the

computing industry as an established development language. The PC has become a cost effective

development platform using C++ or other favored versions of the ANSI standard.

C is a portable language intended to have minimal modification when transferring

programs from one computer to another. This is fine when working with PC’s and mainframes,

but Microcontrollers and Microprocessors are different breed. The main program flow will

basically remain unchanged, while the various setup and port/peripheral control will be micro

specific. An example of this is the port direction registers on a PICmicro®MCU are set 1=Input

0=Output, whereas the H8 is 0=Input and 1=Output.

The use of C in Microcontroller applications has been brought about by manufacturers

providing larger program and RAM memory areas in addition to faster operating speeds.

3.2 Software Listing:

The main purpose of the microcontroller software is to provide an inverter fast feedback loop

response, such that the transient response and output distortion are that of a high performance

design.

In addition, the inverter software may be used to provide the necessary communication to

any ―housekeeping‖

code as well as synchronization of the output voltage to the input voltage waveform. The

housekeeping software was not developed for this reference design; however, the inverter

software has ―hooks‖ in place for such interfacing.

Page 38: Micro Controller Based UPS

38

#include <16F876A.h>

#device *=16

#device ADC=8

#fuses HS,WDT,PUT,BROWNOUT,NOPROTECT,NOLVP,NOCPD

#use delay(clock=20000000, RESTART_WDT)

#use fast_io(B)

#use fast_io(C)

#define ab_chan 0

#define stdby_chan 1

#define i_chan 2

#define acc_chan 3

#define v_chan 4

const long sine_wave[32] = {81,162,241,318,392,462,527,588,642,691,733,768,795, // sine

wave constants;

815,827,831,827,815,795,768,733,691,642,588,527,462,

392,318,241,162,81,0};

const int volt_sine_ref[32] = {0,5,9,14,18,23,27,31,34,37,40,42,44,46,47,48,48,

48,47,46,44,42,40,37,34,31,27,23,18,14,9,5};

//const int delta_v_h[16] = {7,7,6,6,6,5,5,5,4,4,4,3,3,3,2,2};

//const int delta_v_l[16] = {3,3,3,3,3,3,3,2,2,2,2,1,1,1,0,0};

const int delta_corr[32] = {3,6,9,12,15,18,20,23,25,27,28,30,31,31,32,32,32,31,

31,30,28,27,25,23,20,18,15,12,9,6,3,0};

int index, sine_pol, inv_mode, stdby_mode, stdby, i, inv_on, inv_off;

int low_curr_h, low_curr_l, over_curr, short_curr, high_ab, stdby_go_blink;

int low_acc, high_acc, high_t_stop, high_t_blink, low_curr;

int low_acc_delay, acc_avg_counter, volt_ref_counter, volt_l_avg_counter, volt_h_avg_counter;

int volt_h, volt_l, volt_h_avg, volt_l_avg, delta;

int acc_v, acc_v_avg, volt_a, volt_b, stdby_i, stdby_i_h, stdby_i_l, stdby_i_avg_counter;

int volt_ref, volt_ref_avg, curr_h, curr_l, curr_h_avg, curr_l_avg;

signed int delta_h_v, delta_l_v, delta_h_ref, delta_l_ref, volt_ref_delta;

signed long int level_corr[32];

signed int shape_corr[32];

long int pwm_pos, pwm_neg;

long int volt_h_temp, volt_l_temp, volt_ref_temp, acc_v_temp, over_curr_delay;

long int stdby_delay, stdby_go_delay, high_t_delay, curr_h_temp, curr_l_temp, stdby_i_temp;

const long pwm_max=1023;

const int curr_l_max=32, short_curr_l=16, ab_max=96, volt_ref_const_h=180,

volt_ref_const_l=75;

const int stdby_i_h_max=239, stdby_i_h_min=143, stdby_max=253, stdby_min=2;

const int curr_h_max=223, curr_h_min=143, curr_l_min=111, short_curr_h=239;

const int acc_max_l=92, acc_max_h=98, acc_min_l=60, acc_min_h=66;

Page 39: Micro Controller Based UPS

39

#separate

void sine_pwm_start(void) // Start mode;

{

set_pwm1_duty((sine_wave[index]+level_corr[index])>>1); // positive start sine

half wave;

output_high(PIN_C1); // A=1;

output_low(PIN_C0); // Z=0;

output_high(PIN_B1);

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_a=read_adc(ADC_READ_ONLY);

if(volt_a>=ab_max) {

// high_ab++;

if(high_ab>8) break;

}

else high_ab=0;

output_low(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_h=read_adc(ADC_READ_ONLY);

if(curr_h>=short_curr_h) {

short_curr++;

if(short_curr>8) break;

}

else {

short_curr=0;

if(curr_h>curr_h_max) over_curr_delay++;

else over_curr_delay=0;

}

}

#separate

void sine_pwm_norm(void) // Normal mode;

{

switch (sine_pol) {

case 0: // negative sine half wave;

set_adc_channel(v_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

Page 40: Micro Controller Based UPS

40

delay_us(20);

volt_l=read_adc(ADC_READ_ONLY);

volt_l_temp+=volt_l;

pwm_neg=sine_wave[index] + shape_corr[index] + level_corr[index];

if(pwm_neg>pwm_max) pwm_neg=pwm_max;

//if(pwm_neg<0) pwm_neg=0;

set_pwm1_duty(pwm_neg);

output_low(PIN_C1); // A=0;

output_low(PIN_C0); // Z=0;

output_low(PIN_B1);

//set_pwm2_duty(volt_l);

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_b=read_adc(ADC_READ_ONLY);

if(volt_b>=ab_max) {

high_ab++;

if(high_ab>4) break;

}

else high_ab=0;

output_high(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_l=read_adc(ADC_READ_ONLY);

if(curr_l<=short_curr_l) {

short_curr++;

if(short_curr>4) break;

}

else {

short_curr=0;

if(curr_l<curr_l_max){

over_curr_delay++;

//level_corr[index+1]-=delta_corr[index+1];

}

else over_curr_delay=0;

}

output_low(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_h=read_adc(ADC_READ_ONLY);

curr_h_temp+=curr_h;

Page 41: Micro Controller Based UPS

41

/*if(index) {

delta_l_v=(127-volt_sine_ref[index])-volt_l;

delta=delta_corr[index-1]>>2;

if(delta_l_v>delta) shape_corr[index-1]--;

else if(delta_l_v<-delta) shape_corr[index-1]++;

}*/

if(index==31) {

curr_h_avg=curr_h_temp>>5;

if((curr_h_avg<stdby_i_h)&&(!inv_on)) low_curr_l=1;

else low_curr_l=0;

volt_l_avg=volt_l_temp>>5;

delta_l_ref=volt_l_avg-(volt_ref_const_l-volt_ref_delta);

if(delta_l_ref>2) for(i=0; i<32; i++) level_corr[i]+=delta_corr[i]>>1;

else if(delta_l_ref<-2) for(i=0; i<32; i++) level_corr[i]-=delta_corr[i]>>1;

curr_h_temp=0;

volt_l_temp=0;

high_ab=0;

short_curr=0;

sine_pol=1;

}

break;

case 1: // positive sine half wave;

set_adc_channel(v_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_h=read_adc(ADC_READ_ONLY);

volt_h_temp+=volt_h;

pwm_pos=sine_wave[index] + shape_corr[index] + level_corr[index];

if(pwm_pos>pwm_max) pwm_pos=pwm_max;

//if(pwm_pos<0) pwm_pos=0;

set_pwm1_duty(pwm_pos);

output_high(PIN_C1); // A=1;

output_low(PIN_C0); // Z=0;

output_high(PIN_B1);

//set_pwm2_duty(volt_h);

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_a=read_adc(ADC_READ_ONLY);

if(volt_a>=ab_max) {

high_ab++;

if(high_ab>4) break;

}

else high_ab=0;

Page 42: Micro Controller Based UPS

42

output_low(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_h=read_adc(ADC_READ_ONLY);

if(curr_h>=short_curr_h) {

short_curr++;

if(short_curr>4) break;

}

else {

short_curr=0;

if(curr_h>curr_h_max) {

over_curr_delay++;

//level_corr[index+1]-=delta_corr[index+1];

}

else over_curr_delay=0;

}

output_high(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_l=read_adc(ADC_READ_ONLY);

curr_l_temp+=curr_l;

/*if(index) {

delta_h_v=(127+volt_sine_ref[index])-volt_h;

delta=delta_corr[index-1]>>2;

if(delta_h_v>delta) shape_corr[index-1]++;

else if(delta_h_v<-delta) shape_corr[index-1]--;

}*/

if(index==31) {

curr_l_avg=curr_l_temp>>5;

if((curr_l_avg>stdby_i_l)&&(!inv_on)) low_curr_h=1;

else low_curr_h=0;

volt_h_avg=volt_h_temp>>5;

delta_h_ref=(volt_ref_const_h+volt_ref_delta)-volt_h_avg;

if(delta_h_ref>2) for(i=0; i<32; i++) level_corr[i]+=delta_corr[i]>>1;

else if(delta_h_ref<-2) for(i=0; i<32; i++) level_corr[i]-=delta_corr[i]>>1;

curr_l_temp=0;

volt_h_temp=0;

high_ab=0;

short_curr=0;

sine_pol=0;

}

break;

Page 43: Micro Controller Based UPS

43

}

}

#separate

void sine_pwm_stop(void) // Stop mode;

{

set_pwm1_duty((sine_wave[index]+level_corr[index])>>1); // negative stop sine

half wave;

output_low(PIN_C1); // A=0;

output_low(PIN_C0); // Z=0;

output_low(PIN_B1);

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_b=read_adc(ADC_READ_ONLY);

if(volt_b>=ab_max) {

high_ab++;

if(high_ab>4) break;

}

else high_ab=0;

output_high(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_l=read_adc(ADC_READ_ONLY);

if(curr_l<=short_curr_l) {

short_curr++;

if(short_curr>4) break;

}

else {

short_curr=0;

if (curr_l<curr_l_max){

over_curr_delay++;

//shape_corr[index+1]-=delta_i[index+1];

}

else over_curr_delay=0;

}

}

#separate

void sine_pwm_stdby(void) // Standby mode;

{

Page 44: Micro Controller Based UPS

44

switch (stdby_mode) {

case 0:

sine_pwm_start();

if(index==31) {

high_ab=0;

short_curr=0;

stdby_mode++;

}

break;

case 1: // negative sine half wave;

pwm_neg=sine_wave[index] + level_corr[index];

if(pwm_neg>pwm_max) pwm_neg=pwm_max;

//if(pwm_neg<0) pwm_neg=0;

set_pwm1_duty(pwm_neg);

output_low(PIN_C1); // A=0;

output_low(PIN_C0); // Z=0;

output_low(PIN_B1);

set_adc_channel(v_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_l=read_adc(ADC_READ_ONLY);

volt_l_temp+=volt_l;

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_a=read_adc(ADC_READ_ONLY);

if(volt_b>=ab_max) {

high_ab++;

if(high_ab>4) break;

}

else high_ab=0;

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_l=read_adc(ADC_READ_ONLY);

if(curr_l<=short_curr) {

short_curr++;

if(short_curr>4) break;

}

else {

short_curr=0;

if (curr_l<curr_l_max){

over_curr_delay++;

Page 45: Micro Controller Based UPS

45

//shape_corr[index+1]-=delta_i[index+1];

}

else over_curr_delay=0;

}

output_low(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_h=read_adc(ADC_READ_ONLY);

curr_h_temp+=curr_h;

if(index==31) {

curr_h_avg=curr_h_temp>>5;

if(curr_h_avg>=stdby_i_h) stdby=0;

volt_l_avg=volt_l_temp>>5;

delta_l_ref=volt_l_avg-(volt_ref_const_l-volt_ref_delta);

if(delta_l_ref>2) for(i=0; i<32; i++) level_corr[i]+=delta_corr[i]>>1;

if(delta_l_ref<-2) for(i=0; i<32; i++) level_corr[i]-=delta_corr[i]>>1;

curr_h_temp=0;

volt_l_temp=0;

high_ab=0;

short_curr=0;

stdby_mode++;

}

break;

case 2: // positive sine half wave;

pwm_pos=sine_wave[index] + level_corr[index];

if(pwm_pos>pwm_max) pwm_pos=pwm_max;

//if(pwm_pos<0) pwm_pos=0;

set_pwm1_duty(pwm_pos);

output_high(PIN_C1); // A=1;

output_low(PIN_C0); // Z=0;

output_high(PIN_B1);

set_adc_channel(v_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_h=read_adc(ADC_READ_ONLY);

volt_h_temp+=volt_h;

set_adc_channel(ab_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_b=read_adc(ADC_READ_ONLY);

if(volt_a>=ab_max) {

high_ab++;

Page 46: Micro Controller Based UPS

46

if(high_ab>4) break;

}

else high_ab=0;

output_low(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_h=read_adc(ADC_READ_ONLY);

if(curr_h>=short_curr_h) {

short_curr++;

if(short_curr>4) break;

}

else {

short_curr=0;

if(curr_h>curr_h_max) {

over_curr_delay++;

//shape_corr[index+1]-=delta_i[index+1];

}

else over_curr_delay=0;

}

output_high(PIN_C3);

set_adc_channel(i_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

curr_l=read_adc(ADC_READ_ONLY);

curr_l_temp+=curr_l;

if(index==31) {

curr_l_avg=curr_l_temp>>5;

if((curr_l_avg<=stdby_i_l)) stdby=0;

volt_h_avg=volt_h_temp>>5;

delta_h_ref=(volt_ref_const_h+volt_ref_delta)-volt_h_avg;

if(delta_h_ref>2) for(i=0; i<32; i++) level_corr[i]+=delta_corr[i]>>1;

else if(delta_h_ref<-2) for(i=0; i<32; i++) level_corr[i]-=delta_corr[i]>>1;

curr_l_temp=0;

volt_h_temp=0;

high_ab=0;

short_curr=0;

stdby_mode++;

}

break;

case 3:

sine_pwm_stop();

if(index==31) {

high_ab=0;

Page 47: Micro Controller Based UPS

47

short_curr=0;

stdby_mode=0;

inv_mode++;

}

break;

}

}

#int_timer0

void sine_pwm(void)

{

restart_wdt();

clear_interrupt(int_timer0);

set_timer0(60);

if((!low_acc)&&(!high_acc)&&(!inv_off)) { // check acc value and

inverter state;

switch (inv_mode) { // check inverter mode;

case 0: // start mode;

sine_pwm_start();

if(index==31) {

high_ab=0;

short_curr=0;

sine_pol=0;

inv_mode++;

}

break;

case 1: // normal mode;

if((!high_t_stop)&&(!low_curr)&&(!low_acc_delay)) {

output_high(PIN_B4); // Green LED-ON;

output_low(PIN_B5); // Red LED-OFF;

}

sine_pwm_norm();

if(index==31) {

if((low_curr_l)&&(low_curr_h)) { // check for low current;

low_curr=1;

stdby_go_delay++;

if((!low_acc_delay)&&(!high_t_stop)) {

if(stdby_go_blink>30) {

output_high(PIN_B4); // Blink Green&Red LEDs;

output_high(PIN_B5);

}

else {

output_low(PIN_B4);

output_low(PIN_B5);

}

Page 48: Micro Controller Based UPS

48

if(!stdby_go_blink) stdby_go_blink=60;

else stdby_go_blink--;

}

if((stdby_go_delay>600)&&(!sine_pol)) {

stdby=1;

stdby_go_delay=0;

stdby_go_blink=60;

low_curr_l=0;

low_curr_h=0;

low_curr=0;

inv_mode++;

output_low(PIN_B4);

output_low(PIN_B5);

}

}

else {

low_curr=0;

stdby_go_delay=0;

stdby_go_blink=60;

}

}

break;

case 2: // stop mode;

sine_pwm_stop();

if(index==31) {

high_ab=0;

short_curr=0;

inv_mode=4;

}

break;

case 3: // standby mode;

sine_pwm_stdby();

stdby_delay--;

break;

case 4: // idle mode;

set_pwm1_duty(0); // M=0;

if((!high_t_stop)&&(!low_curr)&&(!low_acc_delay)) {

if(stdby_delay>1023) output_high(PIN_B4); // Blink Green LED;

else output_low(PIN_B4);

}

if(!stdby_delay) {

stdby_delay=2047;

if(stdby) inv_mode=3;

else inv_mode=0;

}

else stdby_delay--;

Page 49: Micro Controller Based UPS

49

break;

}

if(index==15) {

set_adc_channel(acc_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

acc_v=read_adc(ADC_READ_ONLY);

acc_v_temp+=acc_v;

acc_avg_counter++;

if(acc_avg_counter==32) {

acc_avg_counter=0;

acc_v_avg=acc_v_temp>>5;

if(acc_v_avg<=acc_min_l) {

low_acc_delay++;

if(!high_t_stop) {

output_low(PIN_B4);

output_high(PIN_B5);

}

if(low_acc_delay==16) {

low_acc=1;

low_acc_delay=0;

}

}

else {

if(acc_v_avg>=acc_max_h) high_acc=1;

low_acc_delay=0;

}

acc_v_temp=0;

acc_v_avg=0;

}

output_low(PIN_C3); // check vref value;

set_adc_channel(stdby_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

volt_ref=read_adc(ADC_READ_ONLY);

volt_ref_temp+=volt_ref;

volt_ref_counter++;

if(volt_ref_counter==32) {

volt_ref_avg=volt_ref_temp>>5;

volt_ref_delta=volt_ref_avg-30;

volt_ref_counter=0;

volt_ref_temp=0;

}

}

Page 50: Micro Controller Based UPS

50

if(index==31) {

if(over_curr_delay>1600) over_curr=1;

if(!input(PIN_C4)) {

high_t_delay++;

output_high(PIN_C5);

if((high_t_delay>255)&&(high_t_delay<1024)) {

high_t_stop=1;

output_low(PIN_B4);

if(high_t_blink>45) output_high(PIN_B5); // Blink Red LED;

else output_low(PIN_B5);

if(!high_t_blink) high_t_blink=90;

else high_t_blink--;

}

else if(high_t_delay>1023) high_t_stop++;

}

else {

high_t_delay=0;

high_t_stop=0;

high_t_blink=90;

output_low(PIN_C5);

}

output_high(PIN_C3); // check stdby current value;

set_adc_channel(stdby_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

stdby_i=read_adc(ADC_READ_ONLY);

stdby_i_temp+=stdby_i;

stdby_i_avg_counter++;

if(stdby_i_avg_counter==32) {

stdby_i=stdby_i_temp>>5;

if(stdby_i>=stdby_max) inv_on=1;

else inv_on=0;

if(stdby_i<=stdby_min) inv_off=1;

stdby_i_h=(stdby_i>>1)+128;

//if(stdby_i_h>stdby_i_h_max) stdby_i_h=stdby_i_h_max;

//else if(stdby_i_h<stdby_i_h_min) stdby_i_h=stdby_i_h_min;

stdby_i_l=255-stdby_i_h;

stdby_i_avg_counter=0;

stdby_i_temp=0;

}

}

index++;

if(index>31) index=0;

}

else { // acc low mode;

Page 51: Micro Controller Based UPS

51

set_pwm1_duty(0); // M=0;

output_high(PIN_C0); // Z=1;

output_low(PIN_B4); // Green LED-OFF;

if(!inv_off) output_high(PIN_B5); // Red LED-ON;

inv_mode=0;

index=0;

short_curr=0;

over_curr=0;

over_curr_delay=0;

high_ab=0;

high_t_delay=0;

high_t_stop=0;

stdby=0;

pwm_pos=0;

pwm_neg=0;

delta_h_v=0;

delta_l_v=0;

//delta_h_ref_v=0;

//delta_l_ref_v=0;

//diff_h_v=0;

//diff_l_v=0;

delta_h_ref=0;

delta_l_ref=0;

//delta_h_ref_adj=0;

//delta_l_ref_adj=0;

low_curr_h=0;

low_curr_l=0;

curr_h_temp=0;

curr_h_avg=0;

curr_l_temp=0;

curr_l_avg=0;

low_curr=0;

volt_h_temp=0;

volt_h_avg=0;

volt_l_temp=0;

volt_l_avg=0;

volt_ref_temp=0;

volt_ref_avg=0;

volt_ref_delta=0;

volt_ref_counter=0;

volt_h_avg_counter=0;

volt_l_avg_counter=0;

//volt_l_avg_counter=0;

stdby_i_temp=0;

//stdby_i_avg_counter=0;

stdby_go_delay=0;

Page 52: Micro Controller Based UPS

52

stdby_delay=2047;

high_t_blink=90;

low_acc_delay=0;

stdby_go_blink=60;

//level=0;

//level_corr=0;

//level_l_corr=0;

for(i=0; i<32; i++) {

shape_corr[i]=0;

//shape_l_corr[i]=0;

level_corr[i]=0;

//level_adj[i]=0;

//shape_h_corr_temp[i]=0;

//shape_l_corr_temp[i]=0;

}

output_high(PIN_C3); // check stdby current value;

set_adc_channel(stdby_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

stdby_i=read_adc(ADC_READ_ONLY);

stdby_i_temp+=stdby_i;

stdby_i_avg_counter++;

if(stdby_i_avg_counter==32) {

stdby_i=stdby_i_temp>>5;

if(stdby_i>stdby_min) inv_off=0;

//else inv_off=0;

stdby_i_h=(stdby_i>>1)+128;

//if(stdby_i_h>stdby_i_h_max) stdby_i_h=stdby_i_h_max;

//else if(stdby_i_h<stdby_i_h_min) stdby_i_h=stdby_i_h_min;

stdby_i_l=255-stdby_i_h;

stdby_i_avg_counter=0;

stdby_i_temp=0;

}

set_adc_channel(acc_chan);

delay_us(10);

read_adc(ADC_START_ONLY);

delay_us(20);

acc_v=read_adc(ADC_READ_ONLY);

acc_v_temp+=acc_v;

acc_avg_counter++;

if(acc_avg_counter==32) {

acc_avg_counter=0;

acc_v_avg=acc_v_temp>>5;

if(acc_v_avg<=acc_max_l) high_acc=0;

if(acc_v_avg>=acc_min_h) low_acc=0;

Page 53: Micro Controller Based UPS

53

acc_v_temp=0;

acc_v_avg=0;

}

if(input(PIN_C4)) output_low(PIN_C5);

}

}

void main()

{

set_tris_b(0xCD);

set_tris_c(0x90);

output_high(PIN_C0); // Z=1;

//output_high(PIN_B4); // test LED's;

//output_low(PIN_B5);

//delay_ms(1000);

output_low(PIN_B4);

//output_high(PIN_B5);

//delay_ms(1000);

output_low(PIN_B5);

index=0;

inv_mode=0; // init to normal start mode;

inv_on=0;

inv_off=0;

stdby_mode=0;

short_curr=0;

over_curr=0;

over_curr_delay=0;

high_ab=0;

high_t_delay=0;

high_t_stop=0;

low_acc=0;

high_acc=0;

acc_v_temp=0;

acc_avg_counter=0;

acc_v_avg=0;

stdby=0;

pwm_pos=0;

pwm_neg=0;

delta_h_v=0;

delta_l_v=0;

//delta_h_ref_v=0;

//delta_l_ref_v=0;

//diff_h_v=0;

//diff_l_v=0;

delta_h_ref=0;

Page 54: Micro Controller Based UPS

54

delta_l_ref=0;

//delta_h_ref_corr=0;

//delta_l_ref_corr=0;

low_curr_h=0;

low_curr_l=0;

low_curr=0;

curr_h_temp=0;

curr_h_avg=0;

curr_l_temp=0;

curr_l_avg=0;

low_curr=0;

volt_h_temp=0;

volt_h_avg=0;

volt_l_temp=0;

volt_l_avg=0;

volt_ref_temp=0;

volt_ref_avg=0;

volt_ref_delta=0;

volt_ref_counter=0;

volt_h_avg_counter=0;

volt_l_avg_counter=0;

//volt_l_avg_counter=0;

stdby_i_temp=0;

stdby_i_avg_counter=0;

stdby_go_delay=0;

stdby_delay=2047;

high_t_blink=90;

low_acc_delay=0;

stdby_go_blink=60;

//level=0;

//level_corr=0;

//level_l_corr=0;

for(i=0; i<32; i++) {

shape_corr[i]=0;

//shape_l_corr[i]=0;

level_corr[i]=0;

//shape_h_corr_temp[i]=0;

//shape_l_corr_temp[i]=0;

//level_adj[i]=0;

}

setup_adc_ports(ALL_ANALOG); // init the ADC;

setup_adc(ADC_CLOCK_DIV_32); // Tad=1.6us;

set_adc_channel(acc_chan);

delay_us(10);

for(i=0; i<32; i++) {

acc_v=read_adc();

Page 55: Micro Controller Based UPS

55

acc_v_temp+=acc_v;

if(i==31) {

acc_v_avg=acc_v_temp>>5;

if(acc_v_avg<=acc_min_l) low_acc=1;

if(acc_v_avg>=acc_max_h) high_acc=1;

acc_v_temp=0;

acc_v_avg=0;

}

}

output_high(PIN_C3); // check stdby current value;

set_adc_channel(stdby_chan);

delay_us(10);

for(i=0; i<32; i++) {

stdby_i=read_adc();

stdby_i_temp+=stdby_i;

if(i==31) {

stdby_i=stdby_i_temp>>5;

if(stdby_i<=stdby_min) inv_off=1;

else if(stdby_i>=stdby_max) inv_on=1;

stdby_i_h=(stdby_i>>1)+128;

stdby_i_l=255-stdby_i_h;

stdby_i_temp=0;

}

}

output_low(PIN_C3);

set_adc_channel(stdby_chan); // check vref value;

delay_us(10);

for(i=0; i<32; i++) {

volt_ref=read_adc();

volt_ref_temp+=volt_ref;

if(i==31) {

volt_ref_avg=volt_ref_temp>>5;

volt_ref_delta=volt_ref_avg-29;

volt_ref_temp=0;

}

}

setup_timer_2(T2_DIV_BY_1, 255, 1); // Init the PWM;

setup_ccp1(CCP_PWM);

set_pwm1_duty(0);

//setup_ccp2(CCP_PWM);

Page 56: Micro Controller Based UPS

56

//set_pwm2_duty(0);

setup_wdt(WDT_18MS);

set_timer0(60);

setup_timer_0(RTCC_INTERNAL|RTCC_DIV_8); // Init the TIMER0;

enable_interrupts(INT_TIMER0);

enable_interrupts(GLOBAL);

while(TRUE) {

restart_wdt();

if((short_curr)||(high_ab)||(over_curr)||(high_t_stop>1)) { // stop and wait for 60 sec;

set_pwm1_duty(0); // M=0;

output_high(PIN_C0); // Z=1;

disable_interrupts(GLOBAL);

output_low(PIN_B4);

output_low(PIN_B5);

short_curr=0;

over_curr=0;

over_curr_delay=0;

high_ab=0;

high_t_stop=0;

high_t_delay=0;

low_acc=0;

high_acc=0;

acc_avg_counter=0;

acc_v_temp=0;

acc_v_avg=0;

low_curr_h=0;

low_curr_l=0;

index=0;

inv_mode=0;

inv_on=0;

inv_off=0;

stdby_mode=0;

stdby=0;

pwm_pos=0;

pwm_neg=0;

delta_h_v=0;

delta_l_v=0;

//delta_h_ref_v=0;

//delta_l_ref_v=0;

//diff_h_v=0;

//diff_l_v=0;

delta_h_ref=0;

delta_l_ref=0;

//delta_h_ref_corr=0;

//delta_l_ref_corr=0;

//level=0;

Page 57: Micro Controller Based UPS

57

//level_corr=0;

//level_l_corr=0;

for(i=0; i<32; i++) {

shape_corr[i]=0;

//shape_l_corr[i]=0;

level_corr[i]=0;

//level_adj[i]=0;

//shape_h_corr_temp[i]=0;

//shape_l_corr_temp[i]=0;

}

curr_h_temp=0;

curr_h_avg=0;

curr_l_temp=0;

curr_l_avg=0;

low_curr=0;

volt_h_temp=0;

volt_h_avg=0;

volt_l_temp=0;

volt_l_avg=0;

volt_ref_temp=0;

volt_ref_avg=0;

volt_ref_delta=0;

volt_ref_counter=0;

volt_h_avg_counter=0;

volt_l_avg_counter=0;

//volt_l_avg_counter=0;

stdby_i_temp=0;

stdby_i_avg_counter=0;

stdby_go_delay=0;

stdby_delay=2047;

high_t_blink=90;

low_acc_delay=0;

stdby_go_blink=60;

delay_ms(30000);

if(input(PIN_C4)) output_low(PIN_C5);

clear_interrupt(int_timer0);

set_timer0(60);

enable_interrupts(GLOBAL);

}

}

}

Page 58: Micro Controller Based UPS

58

3.3 Software Flowchart:

Page 59: Micro Controller Based UPS

59

Chapter 4

System Operation

4.1 Introduction

Design is a sine-wave stand-alone PWM voltage-source inverter (Not UPS) with PIC16F876A

MCU, with parameters:

Uin=12V DC

Uo=230V AC

F= 50Hz

P=500W

Inverter have an integrated input under/over voltage protection, output voltage regulation, output

current protection and overtemperature protection.

Output voltage is a pure sine-wave, generated with built-in PWM module of PIC MCU, with

frequency 20Khz.

Carrier frequency is 20kHz (generated with buit-in PWM of the PIC MCU) and each half

period (10ms) we have 32 changes in the PWM signal, this makes 64 changes in whole period

(20ms). But we generated only the half period of the sine-wave and with the help of the direction

signal we can get the whole period of the sine-wave in the output of the inverter.

Sinewave Lookup Table calculation:

Ki = PWMmax*sin(i*180/n),

where:

PWMmax=0-1023, (PWMmax=831)

i = 0,1,2,...,n

e.g const long sine_wave[32] = {81,162,241,318,392,462,527,588,642,691,733,768,795,

815,827,831,827,815,795,768,733,691,642,588,527,462,

392,318,241,162,81,0};

In this inverter we have a full-bridge power circuits with 4 transistors (paralleled-8

transistors), Q1, Q3, Q5 and Q7. Two of transistors works with low frequency - 50Hz (Q5 and

Page 60: Micro Controller Based UPS

60

Q7) depending on the state of the A/B (direction) signal (RC1). Other two transistors (Q1 and

Q3) works with high-frequency (20kHz) of the sinewave PWM signal.

Efficiency of this inverter is around 80-85% and depends on the transformer design,

MOSFET Quality (lower Rds, less power losses) and the Output Power (or Input Current).

Higher input current through the MOSFETs leads to more power dissipation on transistors.

4.2 LED status:

1. Green -> Normal operation

2. Green Blinking -> Standby Mode (No load operation)

3. Red -> Low baterry (<10.8V)

4. Red Blinking -> Over Temperature of Power Transistors

5. Orange (Green+Red) Blinking-> Before going in Stanby Mode (for 5 sec).

The green LED (LED1) is connected to pin25 (RB4) and red LED - to pin26 (RB5). When

inverter turned ON without load, after 5 sec inverter stops and going in standby mode. In this

mode inverter starts only for short time for detecting the existence of the load. Time interval

between this short start pulses is 1 sec. Before this mode begin to blink Green LED (for 5 sec).

And after going in standby mode blinking Green and Red LEDs together (Use a single two color

LED - Green and Red) and resulting color is orange.

4.3 Transformer:

For the output power transformer we use a low frequency (50Hz) conventional transformer,

but decision is yours. Ferrite core transformers are more suitable in other type of inverters with

double conversion stages,first stage for boosting the input 12V (or 24V) DC voltage to 350-400V

dc ( with HF PWM and ferrite transformer ) and second for inverting this voltage to 230 Vac

(without transformer ).

4.4 Feedbacks:

There are many feedback input signal needed for proper work of the inverter:

From input DC voltage, temperature sensor (Rt, NTC-47k), output ac current, output ac voltage

(230V), a/b signals (over two low-side power transistor - Q5 and Q7), signals from two POT's

(R22 and RT1) and etc. Better look at schematics of the inverter for signals connected to PIC

Page 61: Micro Controller Based UPS

61

MCU.

When starting the inverter for the first time (before connectin the voltage and current

feedback signals to PIC MCU) you must fit (adjust) the polarity of the output signals (I and V) to

the polarity of the direction signal A/B (LF, 50Hz signal) from PIC MCU. Signals must be

exactly like this: positive output voltage (and high current - curr-h) must be at the same time

when signal A/B =5V (log.1) and negative when A/B=0V (log.0).

If the voltage (and current) signals are contrariwise you must reverse only input or output

pins of the power transformer. For contrariwise current signal you must reverse the pins (inpu or

output) of the current transformer. And then you can connect this feedback signals to PIC MCU.

b/a signal (pin2 - RA0/AN0) must include only a low levels of the separeted 'a' and 'b' signals

(pin2 and pin1 - U10). If b/a signal include only a high-levels of signals 'a' and 'b', then you must

change a connection places of this two signals to pin1 and pin2 of the U10 (a<->b and b<->a).

Input current is a DC and can be measured only with current sensing resistor (nonisolated) and

Hall sensor (Isolated). This method is a prefarable only for input current measurement (for

MPPT in Photovoltaic converters) and for input current protection.

Output current of the inverters is a AC an can be measured with current sensing resistor, Hall

sensor and Current transformer. This method is a preferable when implementing an output

current control and regulation.

Current transformers secondary side has a two load resistors: R8=100 for high range and

R18=1.5k for low range. They are in the feedbacks of two OPAMPs (U1A and U1C).

These two OP AMPs (U1A and U1C) forms two active current to voltage converters

with two different current to voltage gain ratios.

For more info just look here:

http://en.wikibooks.org/wiki/Circuit_Idea/Op-amp_Inverting_Current-to-Voltage_Converter

4.5 Other components are :

TLP250 are working from 10-35V and if you supplying them directly from input DC voltage

(before LM317) they can work in overall input voltage range (10.8-16Vdc).

"bootstrap"supply, components D6-C17 (for U3) and D7-C18 (for U3) in inverter schematics.

And it is a specially designed only for high-side drivers. For more information see below link

http://www.intersil.com/data/fn/fn9087.pdf

Page 62: Micro Controller Based UPS

62

D4 is for high voltage battery protection, and D5 is for reverse battery protection of the V_BAT

analog input of PIC MCU (RA3).

4.6 UPS Conversion:

This requires additional circuits as:

1. Zero-cross detection for grid synchronization. (Figure 4.1)

2. Relay(s) for switching the load to grid or to UPS output. (Figure 4.2)

3. Battery charger - embedded in UPS or separated.

Figure 4.1

Figure 4.2

Page 63: Micro Controller Based UPS

63

4.7 Output Wave Form:

The output of the circuit is shown below

Figure 4.3: Output waveform

4.8 Problem Encounter:

All feedbacks must be connected to circuit for proper function of inverter but unfortunately we

are unable to get Current Transformer from market, so our output is damping out but still pure

sine wave and shown in Figure 4.4

Page 64: Micro Controller Based UPS

64

Figure 4.4: Damped Output

4.9 PCB and Assembly:

1) PCB

i) Top Layer

ii) Bottom Layer

iii) Top Overlay

2) Assembly

i) Top Assembly

ii) Bottom Assembly

All figures as following

Page 65: Micro Controller Based UPS

65

Top Layer:

Page 66: Micro Controller Based UPS

66

Bottom Layer:

Page 67: Micro Controller Based UPS

67

Top Overlay:

Page 68: Micro Controller Based UPS

68

Top Assembly:

Bottom Assembly:

Page 69: Micro Controller Based UPS

69

Recommendations and Refrences

Recommendations:

For Proper working of Circuit following parameters must be ensured:

V_OUT = 2.5V +/- max 1.5V (min 1V, max 4V, middle point 2.5V, sine wave)

curr_h = 2.5V +/- max 1V (min 1.5V, max 3.5V, middle point 2.5V, sine wave)

curr_l = 2.5 V +/- max 0.25V (middle point 2.5V, sine wave)

volt = 4.45 - 4.82 Vdc

Stdby = 0 - 5 Vdc

b/a - depending on MOSFET Rds and output current magnitude, approx. 1 - 2V max.

Active level of OE signal is low level (Log. "0").

A/B direction signal is a square wave signal with frequency 50Hz and 50% duty cycle.

For correct work of the inverter all feedback signals must be connected to the PIC MCU,

with normal working levels.

Refrences:

1) UNINTERRUPTIBLE POWER SUPPLIES AND ACTIVE FILTERS

By Ali Emadi, Abdolhosein Nasiri

2) Uninterruptible power supplies

By WilliamKnight

3) Uninterruptible power systems (UPS)

By IEC

4) IEEE 446

Orange Book, Emergency and Standby Power Systems for Industrial and Commercial

1) Applications, (1996) (cited in paragraph 2-3, Table 3-1)

5) IEEE 450

Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid

Batteries for Stationary Applications, (1995) [cited in paragraphs 3-2b(2), 5-2c, 5-2c(1), 5-

2c(2)(k), 5-2f(4), 5-2f(5)(6)]

6) ANSI/IEEE 519

Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems,

(1992) (cited in table 2-2)

Page 70: Micro Controller Based UPS

70

Appendix A

Controller:

PIC16F87XA:

High-Performance RISC CPU:

o Only 35 single-word instructions to learn

o All single-cycle instructions except for program branches, which are two-cycle

o Operating speed: DC – 20 MHz clock input

- DC – 200 ns instruction cycle

o Up to 8K x 14 words of Flash Program Memory,

o Up to 368 x 8 bytes of Data Memory (RAM),

o Up to 256 x 8 bytes of EEPROM Data Memory

o Pinout compatible to other 28-pin or 40/44-pin

o PIC16CXXX and PIC16FXXX microcontrollers

Analog Features:

o 10-bit, up to 8-channel Analog-to-Digital Converter (A/D)

o Brown-out Reset (BOR)

o Analog Comparator module with:

- Two analog comparators

- Programmable on-chip voltage reference

- (VREF) module

- Programmable input multiplexing from device

- inputs and internal voltage reference

- Comparator outputs are externally accessible

Figurer A: Pin configuration

Page 71: Micro Controller Based UPS

71

Special Microcontroller Features:

o 100,000 erase/write cycle Enhanced Flash program memory typical

o 1,000,000 erase/write cycle Data EEPROM memory typical

o Data EEPROM Retention > 40 years

o Self-reprogrammable under software control

o In-Circuit Serial Programming™ (ICSP™) via two pins

o Single-supply 5V In-Circuit Serial Programming

o Watchdog Timer (WDT) with its own on-chip RC oscillator for reliable operation

o Programmable code protection

o Power saving Sleep mode

o Selectable oscillator options

o In-Circuit Debug (ICD) via two pins

Page 72: Micro Controller Based UPS

72

Appendix B

ANALOG MULTIPLEXER/DEMULTIPLEXER:

HCF4053B

DESCRIPTION:

The HCF4053B is a monolithic integrated circuit fabricated in Metal Oxide Semiconductor

technology available in DIP and SOP packages.The HCF4053B analog multiplexer

demultiplexer is a digitally controlled analog switch having low ON impedance and very low

OFF leakage current. This multiplexer circuit dissipate extremely low quiescent power over the

full VDD - VSS and VDD - VEE supply voltage range, independent of the logic state of the

control signals.

When a logic "1" is present at the inhibit input terminal all channel are off. This device is a triple

2-channel multiplexer having three separate digital control inputs, A, B, and C, and an inhibit

input. Each control input selects one of a pair of channels which are connected in a single pole

double-throw configuration.

Figure B1: Pin Diagram

Electrical Characteristics:

Page 73: Micro Controller Based UPS

73

ALTERNATE:

MC14053B

Figure B2: Pin Configuration

Page 74: Micro Controller Based UPS

74

Appendix C

Quad Operational Amplifiers:

LM324

Unique Characteristics

o In the linear mode the input common-mode voltage range includes ground and the output

voltage can also swing to ground, even though operated from only a single power supply

voltage

o The unity gain cross frequency is temperature compensated

o The input bias current is also temperature compensated

Advantages

o Eliminates need for dual supplies

o Four internally compensated op amps in a single package

o Allows directly sensing near GND and VOUT also goes to GND

o Compatible with all forms of logic

o Power drain suitable for battery operation

Features o Internally frequency compensated for unity gain

o Large DC voltage gain 100 dB

o Wide bandwidth (unity gain) 1 MHz (temperature compensated)

o Wide power supply range:

o Single supply 3V to 32V or dual supplies ±1.5V to ±16V

o Very low supply current drain (700 μA)—essentially independent of supply voltage

o Low input biasing current 45 nA (temperature compensated)

o Low input offset voltage 2 mV and offset current: 5 nA Input common-mode voltage

range includes ground

o Differential input voltage range equal to the power supply voltage

o Large output voltage swing 0V to V+ − 1.5V

Page 75: Micro Controller Based UPS

75

Figure C1: Pin Diagram

ALTERNATE:

i. LM124

ii. LM224

iii. LM2902

Page 76: Micro Controller Based UPS

76

Appendix D

Dual Comparator:

LM393

General Description

The LM193 series consists of two independent precision voltage comparators with an offset

voltage specification aslow as 2.0 mV max for two comparators which were designed

specifically to operate from a single power supply over a wide range of voltages. Operation from

split power supplies is also possible and the low power supply current drain is independent of the

magnitude of the power supply voltage. These comparators also have a unique characteristic in

that the input common-mode voltage range includes ground, even though operated from a single

power supply voltage.

Advantages

High precision comparators

Reduced VOS drift over temperature

Eliminates need for dual supplies

Allows sensing near ground

Compatible with all forms of logic

Power drain suitable for battery operation

Figure D1:Pin Configuration

Page 77: Micro Controller Based UPS

77

ALTERNATE:

i. LM193

ii. LM293

iii. LM2903

Page 78: Micro Controller Based UPS

78

Appendix E

Data Line Selector:

SN74HC257

These devices are designed to multiplex signals from 4-bit data sources to 4-output data lines in

bus-organized systems. The 3-state outputs do not load the data lines when the output-enable (G)

input is at a high logic level. To ensure the high-impedance state during power up or power

down, G should be tied to VCC through a pullup resistor; the minimum value of the resistor is

determined by the current-sinking capability of the driver.

Figure E1: Pin Configuration

Table E1

Page 79: Micro Controller Based UPS

79

Figure E2: Logic Diagram

Page 80: Micro Controller Based UPS

80

Appendix F

Gate Drive:

TLP250

The TOSHIBA TLP250 consists of a GaAlAs light emitting diode and a integrated

photodetector.

This unit is 8−lead DIP package.

TLP250 is suitable for gate driving circuit of IGBT or power MOS FET.

__ Input threshold current: IF=5mA(max.)

__ Supply current (ICC): 11mA(max.)

__ Supply voltage (VCC): 10−35V

__ Output current (IO): ±1.5A (max.)

__ Switching time (tpLH/tpHL): 1.5μs(max.)

__ Isolation voltage: 2500Vrms(min.)

__ UL recognized: UL1577, file No.E67349

__ Option (D4) type

VDE approved: DIN VDE0884/06.92,certificate No.76823

Maximum operating insulation voltage: 630VPK

Highest permissible over voltage: 4000VPK

Page 81: Micro Controller Based UPS

81

Figure F1:Pin Configuration

Page 82: Micro Controller Based UPS

82