microprocessor-conductivity-meter-economy

6
Acm-MP DDS An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products Economical Microprocessor Based Conductivity Meter

Upload: acmas-technologies-pvt-ltd

Post on 28-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

Acm-MP DDS An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products ACMAS TECHNOCRACY PVT. LTD. production plants. This microprocessor based table top pH meter is capable of measuring the capacity of ions in an solution to The Acm-MP-DDS - series economical microprocessor based conductivity meter is ideal for routine use in schools, laboratories and www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com carry electrical current.

TRANSCRIPT

Page 1: microprocessor-conductivity-meter-economy

Acm-MP DDS

An ISO 9001:2208 | ISO 14001:2008 | ISO 13485WHO:GMP Products | GLP Compliant Products

Economical MicroprocessorBased Conductivity Meter

Page 2: microprocessor-conductivity-meter-economy

Acm-MP DDS

ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

The Acm-MP-DDS - series economical microprocessor based conductivity meter is ideal for routine use in schools, laboratories and

production plants. This microprocessor based table top pH meter is capable of measuring the capacity of ions in an solution to

carry electrical current.

Economical MicroprocessorBased Conductivity Meter

Page 3: microprocessor-conductivity-meter-economy

ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

Key Features

Single Point Push-Button Calibration:

Acm-MP-DDS - series economical microprocessor based

conductivity meters are equipped with single point calibration

function. The meter is permitted to use user-defined solution,

You need only set conductivity value of the solution under

temperature 25 o C and immerse probe in the solution. Press

[ENTER], the meter will calibrated automatically.

Auto-Ranging for Conductivity:

Our conductivity meters have auto-ranging function. It will

scan the current value and transfer the range, Final

measured value will also displayed on the screen in the most

precise resolution.

Automatic temperature compensation:

Acm-MP-DDS - series economical microprocessor based

conductivity meters are equipped with automatic

temperature compensation and measurement function, the

meter will recognize temperature sensor automatically and

measure temperature after temperature sensor connected to

the meter.

If you connect the conductivity electrode in the same time, it

will begin to the automatic temperature compensation.

Adjustable temperature coefficient:

Different ion solution usually have different temperature

coefficient, setting temperature coefficient correctly is very

important to measurement, DDS-W series can be set in the

range of 0~3.9%/oC.

Adjustable cell constant:

When measuring higher or lower conductivity solution, you

should choose conductivity electrode with different constant.

There is three electrode(0.1, 1, 10) constant for your choice,

you can choose according to your electrode. The meter will

display value automatically

Economical MicroprocessorBased Conductivity Meter

Page 4: microprocessor-conductivity-meter-economy

ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

Economical MicroprocessorBased Conductivity Meter

Page 5: microprocessor-conductivity-meter-economy

ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

Technical Features

Model Acm-MP-DDS-11AW Acm-MP-DDS-307W Acm-MP-DDS-12DW

Conductivity Testing Range 0.000~1.999uS/cm, 19.99 uS/cm, 199.9 uS/cm, 1999 uS/cm,

19.99mS/cm, 200.0mS/cm

Conductivity Testing accuracy ±1.5%F.S ±1%F.S ±1%F.S

Temperature Testing Range …… …… 0~100?

Temperature Testing accuracy …… …… ±1?

Coefficient of Temperature compensation 0~3.9% / ?

Calibration point 1 point, input figure

Electrode constant 0.1, 1.0, 10, Adjustable continuously

Temperature compensation range 0~50? manual 0~50?

manual or automatic

Power Supplier 9V/350mA adapter, 220V/50Hz,

OEM available customizing as per 110V/60Hz

External Size 210×205×65

Weight 1.5kg

Page 6: microprocessor-conductivity-meter-economy

SALES OFFICE (INDIA)

312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA

Tel: 0091-11-23646703, 23643054

(M) +91-9313971681| Email: [email protected]

SALES OFFICE (HONG KONG)

Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC).

Tel: 0086-13929598046 | 0086-18922303099

Email: [email protected]

SHOWROOM

141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA

Tel: 0091-0-9312219738 (M) +91-9717741167

Email: [email protected]

SALES OFFICE (RUSSIA)

Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA

Tel: 0049-79592345 | Email: [email protected]

www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

TECHNOCRACY PVT. LTD.