microsoft powerpoint - 4.1 instalacion eltek2
TRANSCRIPT
![Page 1: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/1.jpg)
CMO LAT NI SE CoDeELTEK 2 IMPLEMENTACION TRAINING
![Page 2: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/2.jpg)
2 © Nokia Siemens Networks Presentation / Author / DateFor internal use
InstalaciInstalacióón gabinete y batern gabinete y baterííasas
•SE DEBEN RETIRAR LOS PLASTICOS QUE PROTEGEN LOS FILTROS DE LA PUERTA EN LA PARTE SUPERIOR DEL GABINETE
•IGUALMENTE EN LA PARTE INFERIOR POR DETRAS DEL FAN
![Page 3: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/3.jpg)
3 © Nokia Siemens Networks Presentation / Author / DateFor internal use
TRAINING MATERIAL REVIEW PART # 2:INSTALLATION GUIDE• Recibir los materiales
• - El supervisor o técnico deberá contar con los siguientes documentos para recibir los equipos:
• TSS.- A través de este documento verificar el dimensionamiento delequipo para el site en referencia.
• Call Off.- Usar como material de información de ayuda para verificar eldimensionamiento del equipo.
• Packing List.- Este documento llega conjuntamente con los equipos. Verificar que coincida esta lista con el SMR y chequar la cantidadindicada. Es necesario verificar el estado físico de cada unidad y gabinetes.
• En caso de que falte algún material se debe avisar inmediatamente al coordinador NSN para que genere el SDR respectivo.
• Tomar la precaución de que los equipoos queden en un lugar seguro y protegido.
![Page 4: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/4.jpg)
4 © Nokia Siemens Networks Presentation / Author / DateFor internal use
• Fix it on the SKID (Riel) – sólo equipos tipo outdoor• Es esencial que el gabinete en los sitios tipo outdoor sean instalados sobre rieles o plinth con las
especificaciones técnicas acordados con el cliente. En resumen, es garantizar que el equipo no tengacontacto directo com el piso.
•SE DEBE INSTALAR EN EL MISMO RIEL OMEGA
![Page 5: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/5.jpg)
5 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Cabinet Location - Plinth
![Page 6: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/6.jpg)
6 © Nokia Siemens Networks Presentation / Author / DateFor internal use
• Cable Entries Explanation (Plates/Conduits)
• El cableado debe ser a través de tuberías flexiconduit de 1” y amarrados con tie wraps. El ingreso de los cables pueden ser por laparte lateral y/o posterior del gabinete y enrrutado al MC3 o MC25.
MC3
![Page 7: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/7.jpg)
7 © Nokia Siemens Networks Presentation / Author / DateFor internal use
EstEstáándar de instalacindar de instalacióón para las corazasn para las corazas
BTS ELTEK
![Page 8: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/8.jpg)
8 © Nokia Siemens Networks Presentation / Author / DateFor internal use
MC25
![Page 9: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/9.jpg)
9 © Nokia Siemens Networks Presentation / Author / DateFor internal use
MC25
![Page 10: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/10.jpg)
10 © Nokia Siemens Networks Presentation / Author / DateFor internal use
INSTALACIONES INCORRECTAS
![Page 11: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/11.jpg)
11 © Nokia Siemens Networks Presentation / Author / DateFor internal use
AC / DC / GND Connections
AC.- Tenemos 2 opciones: Monofásico o Bifásico y Trifásico
![Page 12: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/12.jpg)
12 © Nokia Siemens Networks Presentation / Author / DateFor internal use
CONEXIÓN MONOFASICA
CONEXIÓN BIFASICA
![Page 13: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/13.jpg)
13 © Nokia Siemens Networks Presentation / Author / DateFor internal use
CONEXIÓN DC
![Page 14: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/14.jpg)
14 © Nokia Siemens Networks Presentation / Author / DateFor internal use
CONEXIÓN GND
CONEXIÓN
DE TIERRA
![Page 15: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/15.jpg)
15 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Entrada de cables IF, E1 y Ubicación de MW
• Se recomienda que el cableadodebe ir a través de tuberíaflexiconduit, las rutas a seguir debe definirse según el caso.
• Espacio disponible para laubicación de Radio de MW
![Page 16: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/16.jpg)
16 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Instalación de LTE Kit (Alimentación de MW, Equipos adicionales con alimentación 48DC).
![Page 17: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/17.jpg)
17 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Instalación del Smartpack
![Page 18: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/18.jpg)
18 © Nokia Siemens Networks Presentation / Author / DateFor internal use
InstalaciInstalacióón de Rectificadoresn de Rectificadores
1 2
3
4 5
6 - -
•Este es el orden de instalacióncuando la acometida es trifásicade 230 VAC. Debe seguir el ordenpara conectar el rectificador con un tiempo de 2seg
•POR EJEMPLO!!!
![Page 19: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/19.jpg)
19 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Cableado y conexión de baterías + Switch de Bancos
![Page 20: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/20.jpg)
20 © Nokia Siemens Networks Presentation / Author / DateFor internal use
InstalaciInstalacióón gabinete y batern gabinete y baterííasas
•PARA ESTE TIPO DE EQUIPO LAS BATERIAS REPOSAN SOBRE RIELES
Y LA INSTALACION ES IGUAL AL ANTERIOR EQUIPO…Instalar de esta forma los terminales
positivos y negativos de salida del banco
de baterías. Esto en los casos en los que
los terminales sean largos.
![Page 21: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/21.jpg)
21 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Conexión y torques
![Page 22: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/22.jpg)
22 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Ubicación del sensor de temperatura
Debe ser colocado en el
Banco superior en cada
instalación
![Page 23: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/23.jpg)
23 © Nokia Siemens Networks Presentation / Author / DateFor internal use
Instalación de LTE Kit
Se debe retirar bandeja para
La instalación del kit LTE
Tener en cuenta que al instalar el LTE kit no se podrá instalar elcuarto banco de baterías.
![Page 24: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/24.jpg)
24 © Nokia Siemens Networks Presentation / Author / DateFor internal use
OVP Kit.
Este dispositivo es importante por que se encargará de laprotección desobrevoltajes.
![Page 25: Microsoft Powerpoint - 4.1 Instalacion Eltek2](https://reader034.vdocuments.net/reader034/viewer/2022051416/55cf9c8a550346d033aa2f66/html5/thumbnails/25.jpg)
25 © Nokia Siemens Networks Presentation / Author / DateFor internal use
OVP Kit (Over Voltaje Protected