military solid-state relays selection guide selection guide.pdf · high voltage military...

24
Optical Isolation Current Limiting Low Leakage Short-Circuit Protection AC or DC Bidirectional High Voltage Military Solid-State Relays Selection Guide Silicon Carbide

Upload: nguyencong

Post on 08-May-2018

233 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Optical Isolation

Current Limiting

Low Leakage

Short-Circuit Protection

AC or DC

Bidirectional

High Voltage

Military Solid-State RelaysSelection Guide

Silicon Carbide

Page 2: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Teledyne Relays has been the world’s innovative leader in manufacturing ultraminiature, hermetically sealed, electromechanical and solid-state switching products for more than 50 years. The company’s comprehensive product line meets a wide range of requirements for defense and aerospace, industrial, commercial, medical and RF & wireless uses. Business Focus •MILQPL&COTSSolid-StateRelays •MILQPL&COTSElectromechanicalRelays •HiRel(Space)ElectromechanicalRelays •RF&MicrowaveRelays&CoaxialSwitches •IndustrialSolid-StateRelays •SwitchingMatricesMarkets •Commercial&MilitaryAviation •Defense&Aerospace •Telecom/Communications(Wireless) •Instrumentation&Test •IndustrialPower&MotionControl •MedicalApplications

Product AssuranceUnder an aggressive Total Quality Management (TQM)program, Teledyne Relays has embraced a “continuous improvement” culture. With recognized certificationssuch as BoeingD6-82479,MIL-STD-790,AS9100CandISO9001:2008, Teledyne Relays has become a primary supplier of switching solutions with the highest quality and reliability to industry leaders around the world.

Technical Service & Customer SupportTeledyne Relays provides easy access to technical serviceandcustomersupport.Ourwebsitesmakeiteasytofind technical information,buyproductsandevengete-mail responses within 24 hours. Switching solutionsareonlyamouseclickawayatwww.teledynerelays.com or at teledyne-europe.com. Information about coaxswitchesisavailableatwww.teledynecoax.com.

Switching Solutions

20 Years of Life-Cycle Testing — Series CD and HD solid-state relays have undergone 105,000 hours of permanent testing without a single failure. That’s the equivalent of 480 million cycles. Test conditions featured a full load at 50% duty cycle, 85°C ambient temperature and V-load = 60 Vdc. The test parts met all given specifications.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

Page 3: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com

Table of ContentsOutput

Input Package Product / Series PageAC/DC/BI* Current Voltage

DC

20A 270Vdc 4.2-18Vdc LowProfile LD00KQ 1

10A 270Vdc 4.2-32Vdc LowProfile LD00KM 1

1A 60Vdc 8-20mAdc 6-pinDIP C63 1

0.25A 60Vdc 3.8-5.5Vdc Mini-DipMetal FR75 1

2A 60Vdc 3.8-Vdc 6-pinDIP CD 2

2.1A 60Vdc 3.8-32Vdc LowProfile HD 2

5A 60Vdc 0.3-3.8Vdc LowProfile KD/LD 3

2A 60Vdc 3.8-32Vdc LowProfile KD44CF 3

0.25A 100Vdc 4-7Vdc CompactSIP LPBD100 3

0.25A 28Vdc 4-7Vdc CompactSIP LPD60a 4

0.25A 33Vdc 4-Vdc CompactSIP LPD70 4

7A 60Vdc 4.5-5.5Vdc LowProfile M33-2N 4

1.5A 60Vdc 3.8-32Vdc 16-pinDIP SR75-1 4

0.5A 400Vdc 3.8-32Vdc 16-pinDIP SR75-2 4

1A 60Vdc 8-20mAdc 6-pinDIP ZD20CD 5

2A 60Vdc 8-20mAdc 6-pinDIP ZD20CF 5

0.5A 80Vdc 8-20mAdc 6-pinDIP ZD24CC 5

0.4-1.75A 50-360Vdc 3.8-32Vdc 14-pinDIP C47 5

1A 60Vdc 4.5-5.5Vdc 16-pinDIP C75 5

AC

1.1A 20-250Vac 24-32Vdc COTS 3PAK220 6

2-25A 250Vrms 3.8-32Vdc COTS 652 6

2A 250Vrms 3.8-32Vdc LowProfile 682 6

2A 250Vrms 3.8-32Vdc LowProfile KA 7

2A 250Vrms 3.8-32Vdc LowProfile LA 7

BI0.5-2A 80-350Vdc 10-25mAdc 6-pinDIP FB 7

7.5A 150Vdc 4.5-16Vdc LowProfile QB 7

0.5-2.5A 60-400Vdc 10-50mAdc 6-pinDIP C60 8

Appendix:QualityConformanceInspection 9

Appendix:Glossary 10

MiniatureMatrixBox 13

TeledyneCustomHybridSolutions 14

OtherProductsOverview 15-20

• Broader bandwidth (DC - 18GHz)• Signal integrity up to 40Gbps• SPDT, Magnetic Latching• Metal Enclosure for EMI shielding• High Repeatability• 3 Million Cycle Life

RF121 / GRF121

See Page 12

• Greater than 40 Gbps bandwidth• Broad frequency bandwidth, 40 GHz+ • Small form factor, 3mm X 3mm X 1mm • High isolation • Low insertion loss • Switching time of less than 100ns

InP1012

See Page 11

Page 4: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 1 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

Series C63 Optically Isolated DC Solid-State RelaysSeriesC63solid-staterelaysuseanadvanceddesigncapableofswitchingheavyloadsinaphysicallysmall6-pinmini-DIPpackage.TheserelayshaveapowerFEToutputthatensureslowONresistanceandlowleakagecurrent.Opticalisolationensures complete protection of signal lines, power and ground busandcontrolcircuitsfromswitchingnoiseandEMI.

•LowON-stateresistance•Upto1Aoutput•Opticallyisolated•Floatingoutput•Through-holeorsurface-mountconfiguration

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resis-tance Isolation Type Input Current Operating

Temperature Mounting DimensionsLxWxH

C63-10 60Vdc 1Adc 0.55Ω OpticallyIsolated 8–20mA –40°Cto+85°C Through-hole 0.39x0.25x0.15in.9.91x6.35x3.81mm

SC63-10 60Vdc 1Adc 0.55Ω OpticallyIsolated 8–20mA –40°Cto+85°C Surface 0.39x0.25x0.175in.9.91x6.35x4.45mm

Series LD Optically Isolated, Silicon Carbide DC Solid-State RelaySeriesLDsolid-staterelaysutilizeMIL-PRF-28750testmethodsandarepackagedinlow-profilehermeticallysealedcases.Theserelays are contructed with state-of-the-art solid state techniques andfeaturefullyfloatingpowerFEToutputtechnology.Thisallowsthe load to be connected to either output terminal and provides a lowONresistance.Theinputandoutputareopticallyisolated.

•HighVoltage•Opticalisolation•Meets270VdcrequirementsofMIL-STD-704•Low-profilehermeticpackage•MeetsMIL-PRF-28750requirements

IsolationType

OpticallyIsolated

OperatingTemperature

–55°Cto+125°C

Mounting

Through-hole

DimensionsLxWxH2.105x0.81x0.296in.

53.47x20.574x7.518mm

S I L I C O N C A R B I D E D C R E L AY S

Part No.OUTPUT (Load) INPUT (Control)

Load Voltage Load Current ON Resistance Input Voltage

LD00KQ* 270Vdc 20A .025Ω 4.2–18Vdc

LD00KM* 270Vdc 10A 0.042Ω 4.2–32Vdc

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

D C R E L AY S

Series FR75-1 Optically Isolated, Short-Circuit Protected DC Solid-State RelaysTheFR75-1solid-staterelayutilizesapowerFETswitchthatis protected against short circuits and overload currents. The short-circuit protection feature provides protection when a short or overload occurs while the relay is on as well as when the relay is switchedintoashort.TheFR75-1ispackagedinalow-profilemini-DIPmetalpackage.

•Opticalisolation•LowOFF-stateleakage•Switcheshighcurrents•Highnoiseimmunity•Highdielectricstrength

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type Input Voltage Operating Temperature Mounting Dimensions

LxWxH

FR75-1 60Vdc 1Adc 0.32Ω OpticallyIsolated 3.8–5.5Vdc –40°Cto+85°C Through-hole 0.423x0.463x0.19in.10.74x11.76x4.83mm

Page 5: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 2

DC

RE

LA

YS

D C R E L AY S

Series CD Optically Isolated, Short-Circuit Protected DC Solid-State RelaysTheCDsolid-staterelayutilizesthelatestFETtechnologytoprovidealowONresistance.ThecontrolcircuitisbufferedtoenabletherelaytobedrivendirectlyfromstandardCMOSoropen-collectorTTLlogiccircuits.Availableoptionsincludeshort-circuit,current overload protection, and control status. Both options are available either together or separately as standard features.

•Fastswitchingspeed•Opticalisolation•Meets28VdcrequirementsofMIL-STD-704•Low-profilehermeticceramicpackage•MeetsMIL-PRF-28750requirements

Part No.OUTPUT (Load) INPUT (Control) OPTIONS

Load Voltage Load Current ON Resis-tance

Bias Supply Voltage

CMOS Con-trol

Short-Circuit Protection

Control Status

CD00CF* 60Vdc 2Adc 0.22Ω 3.8–6Vdc 250µA

SCD00CF* 60Vdc 2Adc 0.22Ω 3.8–6Vdc 250µA

CD01CF* 60Vdc 2Adc 0.22Ω 3.8–6Vdc 250µA

SCD01CF* 60Vdc 2Adc 0.22Ω 3.8–6Vdc 250µA

CD20CD* 60Vdc 1Adc 0.45Ω 3.8–6Vdc 250µA

SCD20CD* 60Vdc 1Adc 0.45Ω 3.8–6Vdc 250µA

CD21CD* 60Vdc 1Adc 0.45Ω 3.8–6Vdc 250µA

SCD21CD* 60Vdc 1Adc 0.45Ω 3.8–6Vdc 250µA

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

IsolationType

OpticallyIsolated

OperatingTemperature

–55°Cto+105°C

MountingCD=Through-hole SCD=Surface

DimensionsLxWxH0.560x0.395x0.155in.41.22x10.03x3.94mm

Series HD True-Output Status-Feedback DC Solid-State RelaysTheHDsolid-staterelayutilizesthelatesttechnologytoprovidealowONresistanceandanopticallyisolatedoutput.Thecontrolcircuit is buffered to enable the relay to be driven directly from standardCMOSoropen-collectorTTLlogiccircuits.Availableoptions include short-circuit and current overload protection. The second option is a status output line.

•Fastswitchingspeed•Opticalisolation•Meets28VdcrequirementsofMIL-STD-704•Low-profilehermeticceramicpackage•MeetsMIL-PRF-28750requirements

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL OPTIONS

Load Voltage

Load Current

ONResistance

Isolation Type

Bias Sup-ply Voltage

CMOS Control

Operating Temperature Mounting Dimensions

LxWxHShort-Circuit

ProtectionSwitch Status

HD00CF* 60Vdc 2.1Adc 0.15Ω OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+105°C Through-hole 0.890x.530x0.190in.22.6x13.5x4.83mm

HD02CF* 60Vdc 2.1Adc 0.15Ω OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+105°C Through-hole 0.890x.530x0.190in.22.6x13.5x4.83mm

HD20CF* 60Vdc 2.1Adc 0.15Ω OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+105°C Through-hole 0.890x.530x0.190in.22.6x13.5x4.83mm

HD22CF* 60Vdc 2.1Adc 0.15Ω OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+105°C Through-hole 0.890x.530x0.190in.22.6x13.5x4.83mm

HD24CF* 60Vdc 2.1Adc 0.15Ω OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+105°C Through-hole 0.890x.530x0.190in.22.6x13.5x4.83mm

Trip Status

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

Page 6: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 3 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

DC

RE

LA

YS

D C R E L AY S

Series LPBD100 Normally Closed Dual-Output DC Solid-State RelaysTheLPBD100isadual-output100Vdcplasticrelay.Therelayoutput-switch contacts are normally closed and will conduct the loadcurrentuntilavoltageisappliedtotherelayinput.With4voltsor more at the relay input, the output-switch contacts open and the relaynolongerconducts.TheLPBD100assemblycontainstwoindependent, completely isolated relays.

•CompactSIPplasticpackage•Dualoutput:tworelaysinonepackage•Opticalisolation•TwoMOSFETsforreliableoperation•Lowvoltagedrop

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type Input Voltage Operating Temperature Mounting Dimensions

LxWxH

LPBD100 100Vdc 0.25A 5Ω OpticallyIsolated 4–7Vdc –40°Cto+85°C Through-hole 0.79x0.37x0.14in.20.07x9.39x3.55mm

Series KD/LD Optically Isolated, Short-Circuit Protected DC Solid-State RelaysSeriesKDandLDsolid-staterelaysutilizeMIL-PRF-28750testmethodsandarepackagedinlow-profilehermeticallysealedcases.TheyfeaturefullyfloatingpowerFEToutputtechnology.Optionsinclude short-circuit and current overload protection plus a status outputline.Switchstatusreturnsthetruestatusoftheoutputswitchand is optically isolated from the load.

•Fastswitchingspeed•Opticalisolation•Meets28VdcrequirementsofMIL-STD-704•Low-profilehermeticpackage•MeetsMIL-PRF-28750requirements

Part No.OUTPUT (Load) INPUT (Control) OPTIONS

Load Voltage Load Current ON

Resistance Input Current Input Voltage Short-Circuit Protection

Switch Status

KD00CK* 60Vdc 5Adc 0.075Ω 15mAdc(ttl)1mAdc (cmos)

3.8Vdc(ttl)0.3Vdc(cmos)

KD02CK* 60Vdc 5Adc 0.075Ω 15mAdc(ttl)1mAdc (cmos)

3.8Vdc(ttl)0.3Vdc(cmos)

KD20CK* 60Vdc 5Adc 0.100Ω 15mAdc(ttl)1mAdc (cmos)

3.8Vdc(ttl)0.3Vdc(cmos)

KD22CK* 60Vdc 5Adc 0.100Ω 15mAdc(ttl)1mAdc (cmos)

3.8Vdc(ttl)0.3Vdc(cmos)

LD00CM* 60Vdc 5Adc(10Adcwithheatsink) 0.075Ω 15mAdc(ttl)

1mAdc (cmos)3.8Vdc(ttl)0.3Vdc(cmos)

LD02CM* 60Vdc 5Adc(10Adcwithheatsink) 0.075Ω 15mAdc(ttl)

1mAdc (cmos)3.8Vdc(ttl)0.3Vdc(cmos)

LD20CM* 60Vdc 5Adc(10Adcwithheatsink) 0.100Ω 15mAdc(ttl)

1mAdc (cmos)3.8Vdc(ttl)0.3Vdc(cmos)

LD22CM* 60Vdc 5Adc(10Adcwithheatsink) 0.100Ω 15mAdc(ttl)

1mAdc (cmos)3.8Vdc(ttl)0.3Vdc(cmos)

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

IsolationType

OpticallyIsolated

OperatingTemperature

–55°Cto+105°C

Mounting

Through-hole

DimensionsLxWxHKD:

1.375x0.801x0.22in.34.92x20.34x5.59mm

LD:2.105x0.801x0.22in.53.47x20.34x5.59mm

Series KD44CF DC Solid-State Relays with Flat Trip Short-Circuit ProtectionTheKD44CFsolid-staterelayutilizesMIL-PRF-28750testmethods.TheserelaysfeaturefullyfloatingpowerFEToutputsthatallowtheload to be connected to either output terminal and provides a low ONresistance.Atripstatusindicatorturnsonwhenanovercurrentcondition has occurred and the short-circuit protection has been activated.

•Short-circuitandoverloadprotected•Tripstatus•Meets28VdcrequirementsofMIL-STD-704•Low-profilehermeticceramicpackage•MeetsMIL-PRF-28750requirements

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ONResistance

Isolation Type

Bias Supply Voltage

CMOS Con-trol

Operating Temperature Mounting Dimensions

LxWxH

KD44CF* 60Vdc 2Adc 0.30Ω OpticallyIsolated 3.8–32Vdc 250µAdc –55°Cto

+105°C Through-hole

1.375x0.801x0.295in.

34.92x20.34x7.49mm

*A “W” or “Y” suffix denoting Teledyne’s S2R reliability screening level or MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

Page 7: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 4

DC

RE

LA

YS

Series LPD Normally Open Dual-Output DC Solid-State RelaysSeriesLPDdual-outputplasticrelaysofferinternalthermalprotection.Theyutilizeopticalisolationforexcellentinput-to-outputisolation.TheLPDoffersacurrent-limitingoutputtoprotectitselfand associated load circuits from transient current overloads. Duringanovercurrentcondition,theLPDclampsthecurrenttoasafe operating value.

•Currentlimitingoutput•Thermalprotection•Automaticrecovery•Overloadprotection•Lowvoltagedrop

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type Input Voltage Operating Temperature Mounting Dimensions

LxWxH

LPD60a 28Vdc 0.25A 2Ω OpticallyIsolated 4–7Vdc –40°Cto+85°C Through-hole 0.79x0.37x0.14in.20.07x9.39x3.55mm

LPD70 33Vdc 0.25A 2Ω OpticallyIsolated 4–7Vdc –40°Cto+85°C Through-hole 0.79x0.37x0.14in.20.07x9.39x3.55mm

D C R E L AY S

Series M33-2N Transformer Isolated, High-Surge-Current DC Solid-State RelaysTheM33-2Nisamilitary-styleDCsolid-staterelaydesignedforhigh-currentpulseloadapplications.ItfeaturesthelatestpowerFEToutputtechnologytominimizeONresistance.ThisfeatureprovidesminimumoutputvoltagedropandallowstheM33-2Ntoswitchhighpulsecurrentsupto100ampsathighertemperaturesthan those allowable with bipolar devices.

•Fastswitchingspeed•Opticalisolation•Transformerisolated•Low-profile,hermetic,22-pinmetalDIP•MeetsMIL-PRF-28750requirements

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ONResistance

Isolation Type

Bias Supply Voltage

CMOS Con-trol

Operating Temperature Mounting Dimensions

LxWxH

M33-2N* 60Vdc 7A@25°C 0.09Ω Transformer 4.5–5.5Vdc 80µA –55°Cto+125°C Through-hole

1.376x.801x.290in.34.95x20.35x7.36

mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

IsolationType

OpticallyIsolated

OperatingTemperature

–55°Cto+105°C

MountingBasicRelay=Through-hole

SSuffix=SurfaceDimensionsLxWxH0.855x0.25x0.16in.27.71x6.35x4.06mm

Series SR75 Optically Isolated, Short-Circuit Protected DC Solid-State RelaysTheSR75solid-staterelayutilizesapowerFETswitchthatisprotected against overload and short-circuit currents. The short-circuit protection feature not only provides protection should a short or overload occur while the relay is on, but will provide protection shouldtherelaybeswitchedintoashort.Itcomesinthrough-holeorsurface-mount16-pinDIPpackages.

•ForACapplicationusingabridgerectifier•LowOFF-stateleakage•Switcheshighvoltagesandcurrents•Highnoiseimmunity•Highdielectricstrength

Part No.OUTPUT (Load) INPUT (Control)

Load Voltage Load Current ON Resistance Input Voltage

SR75-1* 60Vdc 1.5Adc 0.5Ω 3.8–32Vdc

SR75-1S* 60Vdc 1.5Adc 0.5Ω 3.8–32Vdc

SR75-2* 300Vdc 0.75Adc 2Ω 3.8–32Vdc

SR75-2S* 300Vdc 0.75Adc 2Ω 3.8–32Vdc

*A “W” or “T” suffix denoting Teledyne’s S2R reliability screening level must be added to the part number. See Appendix, page 14.

Page 8: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 5 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

DC

RE

LA

YS

D C R E L AY S

Part No.OUTPUT (Load) INPUT (Control)

Load Voltage Load Current ON Resistance Input Current

ZD20CD* 80Vdc 1Adc 0.55Ω 8–20mA

SZD20CD* 80Vdc 1Adc 0.55Ω 8–20mA

ZD20CF* 60Vdc 2Adc 0.15Ω 8–20mA

SZD20CF* 60Vdc 2Adc 0.15Ω 8–20mA

ZD24CC* 80Vdc 500mA 1Ω 8–20mA

SZD24CC* 80Vdc 500mA 1Ω 8–20mA

*A “W” or “T” suffix denoting Teledyne’s S2R reliability screening level must be added to the part number. See Appendix, page 14.

ZD Optically Isolated, Short-Circuit Protected DC Solid-State RelaysSeriesZDsolid-staterelaysuseanadvanceddesigncapableofswitchingheavyloadsinaphysicallysmall6-pinDIPpackageTheserelayshaveapowerFEToutputthatensureslowONresistanceandlowleakagecurrent.Opticalisolationensurescomplete protection of signal lines, power and ground bus and controlcircuitsfromswitchingnoiseandEMI.

•Short-circuitprotected•Overloadprotected•LowOFF-stateleakage•TripstatusonZD24series•Compact6-pinDIPpackage

IsolationType

OpticallyIsolated

OperatingTemperature

–55°Cto+105°C

MountingZD=Through-hole SZD=Surface

DimensionsLxWxH0.39x0.25x0.15in.9.91x6.35x3.81mm

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type Input Voltage Operating Temperature Mounting Dimensions

LxWxH

C47F-10 50Vdc 1.75Adc 0.15Ω OpticallyIsolated 3.8–32Vdc –40°Cto+100°C Through-hole 0.75x.25x.165in.19.05x6.35x4.19mm

C47F-20 90Vdc 1Adc 0.35Ω OpticallyIsolated 3.8–32Vdc –40°Cto+100°C Through-hole 0.75x.25x.165in.19.05x6.35x4.19mm

C47F-30 180Vdc 0.6Adc 1Ω OpticallyIsolated 3.8–32Vdc –40°Cto+100°C Through-hole 0.75x.25x.165in.19.05x6.35x4.19mm

C47F-40 360Vdc 0.4Adc 2Ω OpticallyIsolated 3.8–32Vdc –40°Cto+100°C Through-hole 0.75x.25x.165in.19.05x6.35x4.19mm

Series C47F Optically Isolated DC Solid-State RelaysTheSeriesC47Fminiaturesolid-staterelaysutilizeaphotovoltaicgeneratordrivinghigh-performancepowerFETchipstoprovidelow-output on resistance and high-output switching capability. The virtualeliminationofoffsetvoltagemakestheserelaysidealforlow-level switching applications as well. Bidirectional switching versions (SeriesC46F)areavailable.

•14-pinDIPpackage•Switcheshighvoltagesandcurrents•Opticalisolation•Floatingoutput•Highnoiseimmunity

Series C75 DC Solid-State Relays with Short-Circuit Protection and Trip StatusSeriesC75-2solid-staterelaysarepackagedina16-pinDIP,withsurface-mountorthrough-holemountingavailable.TheyutilizeapowerFETswitchthatisprotectedagainstoverloadandshort-circuitcurrents.2Sversionsprovideanopen-collectortripstatusfeedbacktotherelay’scontrolside.2SHversionsaddaninternaltransient voltage suppressor for inductive loads.

•Opticallyisolated•LowOFF-stateleakage•Switchescurrentsto1Adc•Highdielectricstrength•Through-holeorsurface-mountconfiguration

Part No.

OUTPUT (Load) INPUT(Control) OPTIONS

Load Voltage Load Current ON Resis-tance Input Voltage Short-Circuit

Protection Trip StatusTransient Voltage

Protection

C75-2 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

SC75-2 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

C75-2S 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

SC75-2S 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

C75-2SH 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

SC75-2SH 60Vdc 1Adc 0.9Ω 4.5–5.5Vdc

IsolationType

OpticallyIsolated

OperatingTemperature

–40°Cto+85°C

MountingC=Through-hole SC=Surface

DimensionsLxWxH0.85x0.250x0.165in.21.59x6.35x4.19mm

Page 9: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 6

AC

RE

LA

YS

A C R E L AY S

Series 3PAK220 3-Phase AC Solid-State RelaysThe3PAK220relayisa3-phasesolid-staterelaywithstatusindication. Relay inputs and outputs are optically isolated. The 3PAK220isacommercial-off-the-shelf(COTS)relaydesignedfor3-phase,47–440HzapplicationswherelowEMIandreliableoperation under conditions of severe environmental stress are a requirement.

•Noheatsinkrequired•ESDclass2complianceperMIL-STD-833,method3015•CompliantwithMIL-STD-704D•Statusverificationoftheinputcommand

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON-StateVoltage Drop Isolation Type Input Voltage Operating

Temperature Mounting DimensionsLxWxH

3PAK220 20–250Vac 1.1Arms 1.5Vrms OpticallyIsolated 24–32Vdc –40°Cto+85°C Epoxy 1.585x1.585x0.750in.40.26x40.26x19.05mm

Model with flange mount available (above). Flange is for mounting purposes only and does not serve as a heat sink.

Series 652 Optically Isolated AC Solid-State RelaysTheSeries652isanACoutputsolid-staterelaydesignedforpowerswitching.Itincorporatesasealed,opticallycoupledsolid-staterelayasazero-voltageturn-ondriver.TheinputcircuitisTTLlogiccompatible.Outputswitchingisaccomplishedbyback-to-backSCRswithabuilt-insnubbercircuit,whichprovidesreliableswitching of both resistive and reactive loads.

•QualifiedtoMIL-PRF-28750•Zero-voltageturn-on,zero-currentturn-off•Logiccompatibleinput•Sealedaluminumcase•HightransientimmunityandlowEMI

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON-StateVoltage Drop

Zero-Cross Window Input Voltage Operating

Temperature Mounting DimensionsLxWxH

652-1* 250Vrms 25A 1.5Vrms ±15V 4–32Vdc –55°Cto+110°C Terminal 2.410x1.57x1.845in.

61.5x39.88x46.86mm

652-2* 250Vrms 25A 1.5Vrms ±40V 4–32Vdc –55°Cto+110°C Terminal 2.410x1.57x1.845in.

61.5x39.88x46.86mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14. -1 = DSCC Drawing Number M28750/10-001; -2 = DSCC Drawing Number M28750/10-002.

Series 682 Optically Isolated AC Solid-State RelaysThe682isastate-of-the-artsolid-staterelaydesignedforuseinACpowerswitchingapplications.Back-to-backSCRsareconfiguredforzero-voltageturn-onandcanhandlecurrentsurgesupto8A.ThepatentedcircuitdesignassuresthelowestpossibleEMIbyvirtuallyeliminatingcommutationspikeswhilemaintainingexcellentnoiseimmunity.

•QualifiedtoMIL-PRF-28750•Zero-voltageturn-onSCRoutput•Logiccompatibleinput•ExtremelylowEMI•Low-profilemetalDIPpackage

PartNo.OUTPUT(Load) INPUT(Control) MECHANICAL

LoadVoltage LoadCurrent ON-StateVoltageDrop IsolationType InputVoltage Operating

Temperature Mounting DimensionsLxWxH

682-1* 250Vrms 2Arms 1.5Vrms OpticallyIsolated 3.8–32Vdc –55°Cto+110°C Through-hole .890x5.30x.190in.22.6x13.5x4.83mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

Page 10: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 7 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

AC

RE

LA

YS

A C R E L AY S

Series KA/LA Optically Isolated AC Solid-State RelaysSeriesKA/LAsolid-staterelaysaredesignedforuseinACpowerswitching applications where safety and reliability are primary concerns. They are ideal for resistive and reactive loads with power factorsaslowas0.2.InverseparallelSCRsareconfiguredforzero-voltage turn on. The relays are available with thermal protection and thermal trip status.

•Opticalisolation•Fullyfloatingoutput•Bufferedcontrol•Integratedsnubbercircuit•Low-profilehermeticpackage

Part No.OUTPUT (Load) INPUT (Control) MECHANICAL OPTION

Load Voltage Load Current ON-State

Voltage DropIsolation

TypeBias Supply

VoltageCMOS

ControlOperating

Temperature Mounting DimensionsLxWxH

Thermal Protection and Thermal Trip Status

KA58HF* 250Vrms 2Arms 1.2Vrms Optically

Isolated 3.8–32Vdc 250µA –55°Cto+110°C

Through-hole

1.375x0.801x0.22in.34.92x20.34x5.59mm

LA00HL* 250Vrms

2Arms(7.5Armswithheatsink)

1.2Vrms OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+110°CThrough-

hole2.105x0.801x0.22in.53.47x20.34x5.59mm

LA58HL* 250Vrms

2Arms(7.5Armswithheatsink)

1.2Vrms OpticallyIsolated 3.8–32Vdc 250µA –55°Cto

+110°CThrough-

hole2.105x0.801x0.22in.53.47x20.34x5.59mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

B I D I R E C T I O N A L R E L AY S

Part No.

OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type

InputVoltage

Operating Temperature Mounting Dimensions

LxWxHDC AC DC AC DC AC

QB00FM* 150Vdc ±150Vdc 7.5Adc ±4.3Adc 0.035Ω 0.10Ω OpticallyIsolated 4.5–16Vdc –55°Cto

+105°C Through-hole 1.870x1.010x0.275in.47.5x25.65x6.99mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

Series QB00FM Bidirectional and DC Output Bidirectional Solid-State RelaysTheQB00FMrelayisanadvancedsolid-statebidirectionalrelaydesignedforhigh-speedpowerswitchingapplications.Itprovideshighreliability,lowlife-cyclecostandexceptionalswitchperformance.TheQB00FMiscapableofswitchingACorDCpowerandissuitableforheatsinkorcircuitcardmounting.Pin6isconnected to the case for additional safety shielding.

•Highvoltageoutput•LowONresistance•PowerFEToutput•Fastswitchingspeed•Highsurgecurrentcapability

Part No.

OUTPUT (Load) INPUT (Control) MECHANICAL

Load Voltage Load Current ON Resistance Isolation Type

InputCurrent

Operating Temperature Mounting Dimensions

LxWxHDC AC DC AC DC AC

FB00CD* 80Vdc ±80Vdc 2Adc ±1Adc 0.15Ω 0.6Ω OpticallyIsolated

10–25mAdc

–55°Cto+120°C Through-hole 0.458x0.418x0.190in.

11.6x10.6x4.83mm

FB00FC* 180Vdc ±180Vdc 1Adc ±0.5Adc 0.25Ω 1Ω OpticallyIsolated

10–25mAdc

–55°Cto+120°C Through-hole 0.458x0.418x0.190in.

11.6x10.6x4.83mm

FB00KB* 350Vdc ±350Vdc 0.5Adc ±0.25Adc 2Ω 8Ω Optically

Isolated10–25mAdc

–55°Cto+120°C Through-hole 0.458x0.418x0.190in.

11.6x10.6x4.83mm

*A “W” suffix denoting Teledyne’s S2R reliability screening level or “Y” suffix denoting MIL-PRF-28750 level must be added to the part number. See Appendix, page 14.

Series FB Low-Leakage, High-Voltage Bidirectional and DC Solid-State RelaysTheSeriesFBrelayisanadvancedsolid-statebidirectionalrelaydesignedspecificallyforhigh-speedswitchinginATEsystems.These devices provide high reliability, low life-cycle cost and exceptionalswitchperformance.TheFBhasveryfastturn-ontimesofunder1msec.OpticalcouplingminimizesEMIgeneration.

•Highvoltageoutput•Extremelylowleakagecurrent(200nA)•BidirectionalpowerFEToutput•Fastswitchingspeed•Low-profilemetal6-pinmini-DIP

Page 11: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 8

BID

IRE

CT

ION

AL

RE

LA

YS

B I D I R E C T I O N A L R E L AY S

Part No.

OUTPUT (Load) INPUT (Control)Load Voltage Load Current ON Resistance

Input CurrentDC AC DC AC DC AC

C60-10 60Vdc ±60Vdc 2.5Adc ±1.25Adc 0.07Ω 0.28Ω 10–50mA

SC60-10 60Vdc ±60Vdc 2.5Adc ±1.25Adc 0.07Ω 0.28Ω 10–50mA

C60-20 100Vdc ±100Vdc 1.5Adc ±0.75Adc 0.2Ω 0.7Ω 10–50mA

SC60-20 100Vdc ±100Vdc 1.5Adc ±0.75Adc 0.2Ω 0.7Ω 10–50mA

C60-30 200Vdc ±200Vdc 1Adc ±0.50Adc 0.45Ω 1.8Ω 10–50mA

SC60-30 200Vdc ±200Vdc 1Adc ±0.50Adc 0.45Ω 1.8Ω 10–50mA

C60-40 400Vdc ±400Vdc 0.5Adc ±0.25Adc 1Ω 4Ω 10–50mA

SC60-40 400Vdc ±400Vdc 0.5Adc ±0.25Adc 1Ω 4Ω 10–50mA

Series C60 Optically Isolated DC and Bidirectional Solid-State Relays SeriesC60solid-staterelaysuseanadvanceddesigncapableofswitchingveryheavyloadsinaphysicallysmall6-pinmini-DIPpackage.TheserelayshaveapowerFEToutputthatensureslowONresistance,nooffsetvoltageandlowleakagecurrent.InadditiontoswitchingDCloads,theversatileC60canswitchACandbidirectional loads as well.

•Lowon-stateresistance•Upto2.5Aoutput•Opticallyisolated•Three-terminaloutput•Through-holeorsurface-mountconfiguration

IsolationType

OpticallyIsolated

OperatingTemperature

–40°Cto+85°C

MountingC=Through-hole SC=Surface

DimensionsLxWxHThrough-hole

0.39x0.25x0.15in. 9.91x6.35x3.81mm

Surface 0.39x0.25x0.175in. 9.91x6.35x4.45mm

Page 12: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 9 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

All tests are 100% unless otherwise noted.Inspection S2RLevel“W” S2R Level “T” MIL-PRF-28750Level“Y”DestructiveWirebondPullTest(Sampletest)MIL-STD-883Method2011

InternalVisualMIL-STD-883Method2017

ConstantAccelerationMIL-STD-883Method2001,5000Gs,Y1axis

TemperatureCyclingMIL-STD-883Method1010,10cycles

Specifiedtemprange

Specifiedtemprange

–55°to+125°C

LoadConditioning3hoursatratedinputandload90%dutycycle,1to30operationspersecond(latchingfaultindicationfordropout)

PreBurn-In(optional) Burn-in TestMIL-STD-883Method1015,160hoursatspecifiedtemperatureandratedload(latchingfaultindicationonfailure)

(48hoursofsametesting for plastic-packagedrelays)

DielectricWithstandingVoltageMIL-STD-202Method301

InsulationResistanceMIL-STD-883Method1003

ElectricalCharacteristicsat–55°C ElectricalCharacteristicsat+25°C ElectricalCharacteristicsat+125°C(orasspecified)

SealMIL-STD-202Method112(Gross)MIL-STD-883Method1014(Fine)

(N/Aforplastic-packagedrelays)

(N/Aforplastic-packagedrelays)

Visual/Mechanical(Sampletest) Solderability(2Samples)MIL-STD-202Method208

APPENDIX: Quality Conformance Inspection

Page 13: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 10

DSCC Defense Supply Center Columbus. Organization that provides information and recommendations to contractors on commonality and selection of parts, and to manufacturers for qualification of the parts.

DSCC Drawing This is a drawing created by DSCC for parts manufactured to a military specification but are not yet qualified to that specification. These parts may be used in military programs until a slash sheet is created and parts are qualified to the military specification.

MIL-PRF-28750 General specification for solid-state relays. This military specification covers the design, construction, manufacture, performance, test, and screening of military solid-state relays. Relays qualified to this specification are JAN branded and are suitable for all military programs.

Relay, Solid-State (SSR) A relay with isolated input and output whose functions are achieved by means of electronic components without moving parts.

Relay, Zero-Voltage Turn-On A relay with isolated input and output in which added control circuitry delays the output turn-on until the zero-voltage transition of the AC sine wave.

Short-Circuit Protection A feature incorporated into the output circuit of a solid-state relay to protect the relay and circuitry against a shorted load. The relay output will turn-off should a short occur. The output can be reset from the control.

Status, Switch Indicates the state of the output. It operates independently of the control/bias and will return a status as long as load voltage and load circuit continuity exists. It is generated from the load supply and creates an offstate leakage from 600 µA to 2 mA.

Status, Flow Indicates whether there is load current flowing. It operates only when the output is conducting and has a threshold of 10% to 20% of the maximum rated output current. It does not create an OFF-state leakage, but only operates when the output circuit is conducting.

Status, Trip This type of status is only applicable for short-circuit protected relays. It provides an indication when the short-circuit protection has been activated and the output has tripped off. It does not indicate the normal state of the output.

Status, Control This type of status provides an indication of control circuit continuity. It is analogous to the second set of contacts of a double-pole electromechanical relay. It does provide much higher output drive capability than the other types of status outputs.

APPENDIX: Glossary

Page 14: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 11 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

DescriptionThe InP1012-40 is a highly compact, reflective SPDT Active RF switch, manufactured using Teledyne’s high speed, low-loss InP HEMT process. The swtich die is packaged in a low-loss, surface mount package, with a small form factor:3mm(L) x 3mm(W) x 1mm(H). It supports a wide frequency range from 300kHz to 40+GHz, and delivers low insertion loss, fast switching time, and good isolation-making this switch ideal for test and measurment, microwave commu-nications, and radar applications. The unique contruction features and manufacturing tech-niques provide excellent robustness to environmental extremes and overall high reliability

Series InP1012-40SPDT 300kHz-40+ GHz Active RF Switch

Signal Integrity Beyond 40Gbps

COAX SWITCHES

Features

• High digital bandwidth, greater than 40Gbps• Fairly high isolation between control and signal paths• Low insertion loss• Various Connectorcs• Very fast switching time of less than 100ns

Frequency Range

300kHz-40+GHz

Bit Rate

40+Gbps

Operate Time

60-100ns

EnclosureLow-LossSurfaceMount

PackageDimensions

3mm(L)x3mm(W)x1mm(H)

Temperature Storage:–55°Cto+125°C Operating:–45°Cto+125°C

Part No.Typical RF Performance

Frequency Insertion Loss(dB) Isolation (dB) Return Loss

(dB)

300KHz 1.0 75 ---

100MHz 1.2 60 23

2GHz 1.4 24 22

4GHz 1.5 24 20

6GHz 1.6 24 20

8GHz 1.8 24 20

12GHz 1.9 24 20

16GHz 2.3 24 24

20GHz 2.5 24 15

40GHz 3.7 20 13

InP1012-40

TYPICAL SIGNAL INTEGRITY CHARAC-TERISTICS @ 40 Gbps

PATTERN GENERATOR SETTINGS• 231-1PRBSsignal• 40Gbpsdatarate• Dataamplitudeof500mVpp

OUTLINE DIMENSIONS

Page 15: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 12

Relay Type

SPDTMagnetic-Latching

Frequency RangeRF121=DC-12GHzGRF121=DC-18GHz

Bit RateRF121=20GbpsGRF121=40Gbps

Mounting RF=Thru-hole

GRF=Surface-Mount(Stub)Available Coil Voltages

5V:CoilResistance(Ω)=61 12V:CoilResistance(Ω)=500

Temperature Storage:–65°Cto+125°C Operating:–55°Cto+85°C

Series GRF121 Electromechanical Relays The ultraminiature GRF121 relay is designed to provide a practical surface-mount switchingsolution with RF performance and repeatability to 18GHz. The GRF121 improves on Teledyne Relays’ heritage of miniature RF relays by incorporating a precision trasmission line structure in the internal construction of the contact system. GRF121 relays feature a unique ground shield to facilitate surface mounting and to extend the frequency range when compared to through-hole solutions.

•Broaderbandwidth(DC-18GHz)•ExcellentSignalintegrityupto40Gbps•HermeticallySealed•HighResistancetoESD•MetalEnclosureforEMIshielding•HighRepeatability•3MillionCycleLife

Part No.Typical RF Performance

Frequency (GHz) VSWR(max) Isolation (dB) Insertion Loss

(dB) (max)

RF121

DC-4 1.3:1 55 0.25

4-8 1.50:1 50 0.45

8-12 2.0:1 40 1.35

GRF121

DC-4 1.1:1 65 0.2

4-8 1.20:1 50 0.2

8-12 1.35:1 40 0.5

12-16 2.0:1 30 0.95

16-18 2.3:1 30 1.1

Series RF121 / GRF121SPDT Magnetic-Latching Up to DC-18GHz RF RelaySignal Integreity up to 40Gbps

Bit Rate EyeHeight EyeWidth JitterP-P40Gbps 95mV 13.34ps 8.73ps

Bit Rate EyeHeight EyeWidth JitterP-P20Gbps 360mV 40.3ps 6.93ps

RF121 : 20 Gbps GRF121 : 40 Gbps

PATTERN GENERATOR SETTINGS• 20GbpsRandomPulsePatternGenerator• 231-1PRBSsignal• PRBSoutputof500mVP-P(nominal)• RFPCBeffect(negligible)notremovedfrommeasurement• Datashownistypicalofbothcontacts

PATTERN GENERATOR SETTINGS• 40GbpsRandomPulsePatternGenerator• 231-1PRBSsignal• PRBSoutputof500mVP-P(nominal)• RFPCBeffect(negligible)notremovedfrommeasurement• Datashownistypicalofbothpoles

Page 16: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 13 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

ENCLOSUREDIMENSIONS

DescriptionTheMiniMatrixSeriesisanidealsolutionthatincorporateTeledyneCoaxSwitches’forofftheself,easytouseapplication.TheMiniMatrixSeriesisdesignedtoallowtheremoteoperationofSPDT,Transfer,orSP3TtoSP8TMulti-Throwswitches.RemoteoperationisaccomplishedviaTCP/IPcommandstotheMatrix’sEthernetinterface.SwitchcontrolisalsoaccessibleviatheUSBvirtualserialport,usingtheprovidedcommandset.ThroughtheseinterfacestheCoaxSwitchcanbeswitchedtothedesiredpositionanditspositioncanbereadforverification.Thedefaultswitchpositionat power up can be set by the user.

Options

•USBonlyorUSB&EthernetControl•TerminatedorNon-Termintated•FailsafeorLatching•VariousConnectorcs•MultipleFrequencyRanges

ENCLOSURE A - FRONT VIEW

ENCLOSURE A - REAR VIEW

CHK APP APP ZONE(SHT)DRAWNBY DATECNNo.

REVISIONREV

CN28955TR1144REVN/C

A

4 3 2 15678

4 3 2 1567

C

8

B

A

D

E

F

C

B

D

E

FEXEMPTFROMDISCLOSUREPURSUANTTOF.O.I.A.5U.S.C.SECTION552(B)(4)

THISDOCUMENTCONTAINSPROPRIETARYINFORMATIONANDSUCHINFORMATIONMAYNOTBEDISCLOSEDTOOTHERSFORANYPURPOSENORUSEDFORMANUFACTURING

PURPOSESWITHOUTWRITTENPERMISSIONFROMTELEDYNERELAYS.

1B 11532

RELEASEREVISION

FINISH:

MATERIAL:

CNNo.

APPROVALS DATE

DRAWN

CHK/ENG

ENGINEER

APPROVED

APPROVED

SIZE CAGECODE DWGNO. REV

SCALE: CAD: SHT OF

TELEDYNE COAX SWITCHES

±.005±.01

.XXX

.XX ±0.5°±1/32FRACTIONDECIMALINCHMETRICANGLE

MILLIMETERSIN[X.XX]IFUSED

[±0.125]

UNLESSOTHERWISESPECIFIED,DIMENSIONSAREININCHES

TOLERANCES(UNLESSOTHERWISESPECIFIED):

DRAWINGSHALLBEINTERPRETEDPERASMEY14.5(M)

THIRDANGLEPROJECTION

SPECIFICATIONS:

1. MATRIXTYPE: DualSP6TFailsafeSwitchArray

2. MATRIXCONFIGURATIONINPUTS: 2OUTPUTS: 12

3. ENCLOSURE

MATERIAL:EXTRUDEDALUMINUMCHASSIS(POLYCARBONATEBEZELSFrontandBack)

FINISH: SULFURICANODIZEPERMIL-A-8625,TYPEIICLASS2(COLOR:CLARIANTBLUEA)

4. CHARACTERISTICIMPEDANCE:50OHMS(NOMINAL)

5. CONTROLINTERFACE: ETHERNET(LAN)andUSB-B

6. OPERATINGPOWER: 24VDC/2.0A

7. RFPOWERHANDLING:??WATTSMAXIMUM(CONTINUOUS),EACHINPUT 11. ALLCOMPONENTSSHALLBERoHSCOMPLIANT8. OPERATINGTEMPERATURERANGE:-25°Cto+65°C 12. INTERNALWIRINGSHALLCONFORMTO(TBD)9. DIMENSIONS: 2.03"[51.5mm]Hx4.92"[124.8mm]Wx6.30"[160mm]D 13. (TBD)10. WEIGHT:(TBD)LBS

CMM-0086MiniSwitchMatrix(OUTLINEDRAWING)

CMM-108-XXX

FRONTVIEWREARVIEW

Number of Switches1to2SPDT,Transfer,

orSP3T-SP8TSwitching Type

Electromechanical

Temperature

Operating:–40°Cto+65°C

Additional Information

Available Connectors SMA,2.92mm,TypeN,TNC

Line Power Universal90-260VAC,47-63Hz

Enclosure A Size (WxHxD)(Non-Terminated SPMT) 5.08”Wide,2.17High,7.75”Depth

Enclosure B Size (WxHxD)(Terminated SPMT) 8.00”Wide,3.00"High,8.00”Depth

Typical Cycle Life 5,000,000 cyclesConnector Types Frequency Range

2.92 mm DC-40GHz

SMA DC-26.5GHz

Type N DC-12GHz

TNC DC-12GHz

EnclosureA

EnclosureB

Miniature MatrixUSB/Ethernet Controlled Matrices

SPDT, Transfer, Multi-Throw

COAX SWITCHES

Page 17: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 14

Teledyne has over 50 years of experience in developing a wide spectrum of custom solutions.Experienced in Custom Hybrid Solutions

Teledyne Relays is a leading manufacturer with the capability of providing build-to-print solutions on hybridmicrocircuitsdevices.Ourcurrentproductsportfolioincludessolidstatepowercontrollers,DC/DCconverters,highcurrentdrivers,digital-analogconverters,activatorcontrolhybrids,deflectionamplifiers,basedrivers,customdesignedmulti-layersthick-film/thinfilmsubstratesandmanymore...

Withover50yearsofheritageinservingthespace,aerospace,anddefensemarkets,Teledynecontinuestoupholdthesamestandardsandcommitmenttoexcellence.Ouroptimizedsolutionsaresupportedbyteamsofengineersandmanufacturingpersonnelwithwiderangingexperiencesindevelopingproductsdeployed in highly demanding applications, such as electrical power systems, radar receivers, and stores management solutions, for ground or aerial defense platforms.

TeledyneisaccreditedbyDefenseLogisticsAgency(DLA)inaccordancewithMIL-PRF-38534,ClassHandClassGQualifiedManufacturersList(QML).Since2014Teledynehassuccessfullylaunchedovertwentyhybridsintoproductionforourcustomers.Wewelcomeopportunitiestopartnerwithourcustomerstoprovidecustomizedsolutionstoyourhybridneeds.Ourtypicalcustomsolutiondevelopmentcycleisasfollows:

Page 18: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 15 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYSPage 15 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 Teledyne Relays

Did you know...Teledyne Relays offers electromechanical relays for various markets?

RF RELAYS

  •  Signal Integrity up to 40Gbps  •  DC - 16GHz  •  Surface-Mount  •  DPDT, SPDT, 4PST and Loopback Relays

MILITARY GRADE RELAYS

  •  Built and tested to meet MIL-PRF-39016  •  Built and tested to meet MIL-PRF-28776  •  Built-in Diodes, Transistor Driver and      CMOS  •  Low Power coils

TELEDYNE ESTABLISHED RELIABILITY RELAYS

  •  Fully defined product requirements and      screening levels  •  Spacer/Spreader pad options not allowed      by military specifications  •  Reduced lead time and cost vs Military      Grade

HIGH PERFORMANCE RELAYS

  •  -65 °C to +200 °C  •  Shock up to 4,000 g’s  •  Vibration up to 380 g’s   •  Non-Latching & Magnetic-Latching

COMMERCIAL RELAYS

  •  Standard electrical tests at 25 °C  •  “Low cost” switching solutions  •  Surface-Mount  •  Short lead times

Page 19: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 16

Teledyne Coax Switches offers coaxial switches for ATE, Radar, Amplifier Switching, Etc.?

SPDT SWITCHES

  •  DC - 40GHz, Internal 50 Ω Termination  •  SMA, mini-SMB, TNC & N Connectors  •  5 Million Cycles  •  High Power & Low PIM  •  Failsafe & Latching

TRANSFER SWITCHES

  •  DC - 18GHz  •  SMA, TNC & N Connectors  •  5 Million Cycles  •  High Power  •  Failsafe & Latching

MULTI-THROW SWITCHES

  •  DC - 40 GHz, Internal 50 Ω Termination  •  SMA, mini-SMB, TNC & N Connectors  •  SP3T - SP10T  •  5 Million Cycles  •  Normally Open & Latching

LOW PIM SWITCHES

  •  DC - 3 GHz  •  SMA, N and 7/16 D Connectors  •  SPDT, Transfer and Multi-Throw  •  Failsafe & Latching

SPECIALTY SWITCHES

  •  DC - 40GHz  •  3-State Attenuated Switch  •  Radiation Shielding  •  Switch Blocks  •  Redundant Diode Configuration

© 2018 Teledyne Coax Switches www.teledynerelays.com Page 16

Did you know... COAX SWITCHES

Page 20: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 17 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

Did you know... Teledyne Relays offers Commercial/Industrial Solid State Relays?

SINGLE PHASE AC SOLID STATE RELAYS

  •  Up to 690Vac, 125A  •  Input & Output Protection  •  Chassis, DIN Rail and PCB Mount  •  Zero-Cross & Random Switching  •  Touch-Proof Covers

DUAL-PHASE AC SOLID STATE RELAYS

  •  Up to 600Vac, 50A  •  Output Protection  •  Chassis and DIN Rail  •  Zero-Cross & Random Switching  •  Touch-Proof Covers

3 & 4 PHASE SOLID STATE RELAYS

  •  Up to 600Vac, 75A  •  Output Protection  •  Chassis and DIN Rail  •  Zero-Cross & Random Switching  •  DC & AC Control

DC SOLID STATE RELAYS

  •  Up to 1400Vdc, 100A  •  Output Protection  •  Chassis, DIN Rail and PCB Mount  •  IGBT and MOSFET  •  Touch-Proof Covers

SOFT START MOTOR CONTROLLERS AND MOTOR REVERSERS

  •  Up to 26kW, 480Vac  •  Star & Delta Configurations  •  DIN Rail  •  Output Protection  •  Built-in Diagnostics and Self Test

Page 17 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 Teledyne Relays

Page 21: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

© 2018 TELEDYNE RELAYS teledynerelays.com Page 18

Did you know...

DC SOLID STATE RELAYS

  •  Meet MIL-PRF-28750  •  Tested Per MIL-STD-704  •  Silicon Carbide MOSFET     •  Up to 250Vdc, 1A  •  Chassis and PCB Mount  •  Short-Circuit Protection  •  Plastic and Hermetically Sealed

BI-DIRECTIONAL/AC SOLID STATE RELAYS

  •  Meet MIL-PRF-28750  •  Tested Per MIL-STD-704  •  Up to 250Vac, 25A  •  Chassis and PCB Mount  •  Short-Circuit Protection  •  Plastic and Hermetically Sealed

COMMERCIAL, LOW POWER, I/O MODULES

  •  Up to 250Vac, 10A  •  Short-Circuit Protection  •  Chassis and PCB Mount  •  Zero-Cross & Random Switching  •  Low Off-State Leakage Current

SILICON CARBIDE TECHNOLOGY

  •  Up to 270Vdc, 20 A  •  Meet MIL-PRF-28750  •  Tested Per MIL-STD-704  •  Low ON resistance  •  Low Profile Hermetic Package

Teledyne Relays offers Military Solid State Relays?

© 2018 Teledyne Coax Switches www.teledynerelays.com Page 18

Page 22: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Page 19 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS

Did you know... Teledyne Coax Switches offers coaxial switch matrices for ATE, Radar, Filter Switching, Airborne Surveillance Systems, Etc.?Teledyne Coax Switches offers coaxial switch matrices for ATE, Radar, Filter Switching, Airborne Surveillance Systems, Etc.?

MINI MATRICES

  •  Remote Control via USB and/or Ethernet  •  GUI controllable  •  Accepts ASCII code  •  Available in 18, 26.5 and 40 GHz  •  SPDT, Transfer and Multi-throw         configurations

MULTIPLEXOR/FANOUT SWITCH MATRICES

  •  Up to 1x1024 Switch Matrix  •  SMA, mini-SMB, TNC & N Connectors  •  Failsafe, Latching or Normally Open      Configurations  •  Switching Systems for 50 Ω & 75 Ω     applications

MIMO/BLOCKING AND MIMO SINGLE CONNECTION SWITCH MATRICES

  •  Up to 1x1024 Switch Matrix  •  SMA, mini-SMB, TNC & N Connectors  •  RS-232, TTL, USB, GPIB, TTL, Ethernet      Control  •  1 Million Cycles  •  Failsafe & Latching

CUSTOMIZED SWITCH MATRICES

  •  EMI/RFI  •  Transient Suppression  •  Ballistic Shock Fatigue  •  Crash Load  •  Altitude

COAX SWITCHES

Page 19 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE © 2018 Teledyne Relays

Page 23: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

Did you know...

SPACE MARKET SEGMENTS SERVED

  •  Deep-Space Probes  •  Manned Programs  •  Communications Satellites     •  Launch Vehicles  •  Earth Observatory / Weather Satellites  •  Commercial / Military Satellites

CAPABILITIES

  •  Logistic Infrastructure  •  Chemical Analysis Lab  •  Scanning Electro Microscope  •  In-house Plating Shop  •  Enviroment Test Lab  •  Field Technical Support

ELECTROMECHANICAL RELAY SPECIFICATIONS

  •  MIL-PRF-39016  •  MIL-PRF-28776  •  NASA/GSFC S-311-P-754  •  NASA EEE-INST-002  •  ESA/SCC 3601 & 3602

Teledyne Relays offers Space Qualified Switches?

© 2018 Teledyne Coax Switches www.teledynerelays.com Page 20

Page 24: Military Solid-State Relays Selection Guide Selection Guide.pdf · High Voltage Military Solid-State Relays ... The FR75-1 solid-state relay utilizes a power FET switch that is protected

PRINTED IN U.S.A. TR0118

HEADQUARTERS12525 Daphne Ave.

Hawthorne, CA 90250Phone: (323) 777-0077 or (800) 284-7007

Fax: (323) 241-1287E-mail: [email protected]

EUROPE9-13 Napier RoadWardpark North

Cumbernauld G68 OEFScotland UK

Phone: +44 (0) 1236 453 124Fax: +44 (0) 1236 780 651

E-mail: [email protected]

www.teledynerelays.com