milk - pmr.mx · milk rap testid for ß-lactam residues negative positive ctrl test sensitivity...

2
MILK RAPID TEST FOR ß-LACTAM RESIDUES NEGATIVE POSITIVE CTRL TEST Sensitivity Results Visual interpretation of the result by comparing the intensity of the “TEST” line with the one of the “CTRL” line. BETAXPRESS is a competitive receptor-based assay in dipstick format with high affinity for all ß-lactams molecules in milk. COMPOUNDS LIMITS OF DETECTION (PPB) KIT044 MRL Penicillin-G 2-2,5 4 Ampicillin 3-4 4 Cloxacillin 10-15 30 Cefalonium 2-4 20 Benefits RAPID Results in 3 minutes. SENSITIVE Low limits of detection. RELIABLE AND ROBUST GENERIC Detection of all relevant ß-lactams. USER-FRIENDLY Easily performed on site or in lab. COST-EFFECTIVE ECOLOGICAL PACKAGING 3min VERY FAST VERY SENSITIVE Validation pending.

Upload: others

Post on 19-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: milk - pmr.mx · milk RAP TESTiD foR ß-lAcTAm RESiDuES negative positive CtRL test Sensitivity Results Visual interpretation of the result by comparing the intensity of the “TEST”

mil

k

RAPiD TEST foR ß-lAcTAm RESiDuES

negative positive

CtRL

test

Sensitivity

ResultsVisual interpretation of the result by comparing the intensity of the “TEST” line with the one of the “cTRl” line.

betaxpRess is a competitive receptor-based assay in dipstick format with high affinity for all ß-lactams molecules in milk.

CompoundsLimits of deteCtion (ppb)

kit044 mRL

Penicillin-G 2-2,5 4

Ampicillin 3-4 4

cloxacillin 10-15 30

cefalonium 2-4 20

Benefits

„ RapidResults in 3 minutes.

„ sensitivelow limits of detection.

„ ReLiabLe and Robust

„ geneRiCDetection of all relevant ß-lactams.

„ �useR-fRiendLyEasily performed on site or in lab.

„ Cost-effeCtive

„ eCoLogiCaL paCkaging

3 min

3 min

3 min

3 min3 min

3 min

3 min

„ VERY FAST „ VERY SENSITIVE

Validation pending.

Page 2: milk - pmr.mx · milk RAP TESTiD foR ß-lAcTAm RESiDuES negative positive CtRL test Sensitivity Results Visual interpretation of the result by comparing the intensity of the “TEST”

Reseller

unisensor s.a.

Zi du DossayRue du Dossay, 3B-4020 Wandre (liège)BElGium

Phone +32 4 252 66 02fax +32 4 252 90 [email protected]

www.unisensor.be

How to use

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

1 3

5

2 4

Incubate 3 mInutes

Products ReferenceskiT044 „ BETAxPRESS mk mRl - 96 pc

APP032 „ HEATSENSoR DuoAPP039 „ READSENSoR ESE full cASE

mix milk and Reagents.

place the vial to heating block.

Close and push “staRt”.

place dipstick to Heatsensor.

interpret results.