Page 2: Mini Max Slides

What is MINIMAX FMZ 5000 ?

GT Fire Protection system, CYE10FCU – Fire Control UnitEnsure the protection & safety of the

machine as well as the operatorManual & automatic fire detection &

Alarm systemManual & automatic fire Extinguishing

system

Page 3: Mini Max Slides
Page 4: Mini Max Slides
Page 5: Mini Max Slides

Interface - Overview

Page 6: Mini Max Slides

Detectors/ Sensors

Inputs to the FCUConvert Physical signal to Electric signalHeat DetectorCLTDSmoke DetectorFlame DetectorSwitches – Pressure, Limit, Lock-out, etc

Page 7: Mini Max Slides
Page 8: Mini Max Slides
Page 9: Mini Max Slides
Page 10: Mini Max Slides
Page 11: Mini Max Slides

Sketches For the Connections

Page 12: Mini Max Slides

Input & Output modulesLCD Front PanelLED status displayPower Supply & Backup batteryCPU – Central Card for processingRelays

FCU – Main Panel

Page 13: Mini Max Slides

LCD Front Panel & Keypad

Page 14: Mini Max Slides

Central Card

Page 15: Mini Max Slides

FCU – Logic Program

Supervision & Alarm Activate the Extinguishing system Initiate Trip to the GT Control System Initiate PLST to the GT Control System – Exhaust End

Bearing Switch OFF Ventilation System in case of Fire:-

Combined Pump Block GT Thermal Block

Switch ON Ventilation System in case of >20% LEL Combustible Gas detected:-

GT Thermal Block

Page 16: Mini Max Slides

Logic Diagram

Page 17: Mini Max Slides

FCU – Interface Modules

Modules - I/O Card Physical connections to

Detector/Sensors Segregate the signals based

on Areas and Groups MxM Bus communication Conventional Detector

Module Control Group Relay Module

Page 18: Mini Max Slides
Page 19: Mini Max Slides
Page 20: Mini Max Slides
Page 21: Mini Max Slides

Wiring Diagram

Page 22: Mini Max Slides

Extinguishing System

CO2 SystemArgon SystemDeluge Water System

Page 23: Mini Max Slides

Area: GT Auxiliary Block

Supervision: Wire – break Supervision Pressure Supervision

Activation: Manual Release Button Heat Detector Smoke Detector Flame Detector

Page 24: Mini Max Slides

Area: GT Thermal Block Exhaust End Bearing

Supervision: Wire – break Supervision Pressure Supervision Weight Loss Supervision Limit Switches Lock-out switches

Activation: Manual Release Button Heat Detector CLTD Smoke Detector Flame Detector

Page 25: Mini Max Slides

Area: Combined Pump Block

Supervision: Wire – break Supervision Weight Loss Supervision

Activation: Manual Release Button Heat Detector