Page 1: Mini-Packs Excerpt
Page 2: Mini-Packs Excerpt

www.ajaxboiler.com

MINI-PACK™ WATER HEATERSCompact & Semi-InstantaneousSingle-Wall or Double-Wall Tube Bundles

Features• Close temperature controls with ±4ºF at heater hot water outlet under normal operating conditions• Solid rust-free stainless steel construction on the entire domestic water side and standard stainless steel jacket• Compactly sized requiring minimum space for installation, with vertical or horizontal heater choice• Tube bundle readily accessible without moving, shell or foundation for all single wall models; recommended horizontal mounting of double wall due to coil length• Standard sizes cover hot water output from 1 to 769 GPM simplifying size selection and layout• Quality components for high performance

Standard EquipmentShell• ASME Section VIII Div I vessel• National Board registered• 150 psig design working pressure• Vertical or horizontal model with solid 316L stainless steel construction and 304L stainless steel fittings

Tube Bundle• 150 psig design working pressure• SB-75 seamless copper U-tube• Single wall tubing• 304 stainless steel tube sheet

Support• Steel support stand

Controls• Electric, Pneumatic and Pilot operated control valve for steam Electric and Pneumatic control valve for water• 150 psig ASME pressure relief valve• High limit aquastat• Safety solenoid valve• NEMA 1 control panel• Temperature gauge• 1/6 HP recirculator pump• Condensate orifice trap and steam strainer for steam models

Optional EquipmentShell & Tube Bundle• Horizontal model available• Double wall copper or cupro-nickel (90/10) tubing• Single wall cupro-nickel (90/10) or 316L stainless steel tubing• 250 psig shell and tube design working pressure• 400 psig tube design working pressure, for HTW

Support• Steel horizontal single rack for 2 Mini-Pack™

Mini-Pack™The Ace Series Mini-Pack™ semi-instananeous water heater is dependable and quiet, and provides commercial and institutional buildings with potable hot water. Close temperature controls, outstanding thermal effi ciency, high quality ASME coded construction, and minimum fl oor space requirements make the Mini-Pack™ one of our best selling products.

12

Page 3: Mini-Packs Excerpt

Controls• Electric, pneumatic water valves or pilot operated for steam• Double safety solenoid dump valve• Dual valves setup: 1/2 and 2/3 pneumatic control• Building automation relays• T&P steam trap• Alarm bell with silencer switch

Operating Controls• Digital panel• Remote SetPoint panel• Local monitoring panel• Building Automation panel• Ajax Communication Gateway

The Mini-Pack™ temperature control system keeps the heated water within four degrees of the selected temperature. This close control is accomplished by placing the temperature control element directly in the constant fl ow path of the water leaving the heating surface making so-called “anticipator” devices unnecessary. After the water passes over the control element it enters a tempering chamber between the heating surface and the water outlet.

Another essential part of the temperature control system is the integral circulator. This small pump (1/6 HP) constantly recirculates a portion of the heated water to the cold water inlet making “the total volume of the heater” a tempering chamber. Also eliminates any overheated water pockets caused by control valve lag when hot water demand is suddenly reduced. The pump can also be used to provide recirculation of the water from the fi xtures through a tee fi tting that is provided with the package. Where the hot water return system requires greater recirculation the integral pump size can be pre-selected to provide the duty.

The Mini-Pack™ features total rust free construction with austenitic stainless steel and copper for all domestic water contact surfaces, providing high quality, low maintenance and an extremely cost-effective domestic water heating package. Non-metallic PTFE baffl es are used to prevent tube damage.

The vertical Mini-Pack™ semi-instantaneous heater saves fl oor space, is simple to install and very easy to service and maintain. The vertical unit also provides complete drainage of condensate. Universal mounting brackets allow the Mini-Pack™ to be mounted in the horizontal position.

Photo may vary from actual model

Horizontal Pneumatic Mini-Pack™

Optional horizontal single modelstand or dual model rack.

(as shown)

Photo may vary from actual model

13

A.S.M.E.

Series

Page 4: Mini-Packs Excerpt

www.ajaxboiler.com

MODELA B C D E G J K L1 SHIPPING

WEIGHT(LBS.)

WATER VOL. IN

SHELL (GAL.)SI-V-4-SW-xx 83 40 30 251/4 301/4 12 9 3/4 2 350 2.1SI-V-5-SW-xx 693/4 333/4 23 19 24 12 10 1 21/2 400 2.5SI-V-6-SW-xx 86 42 313/4 261/2 311/2 12 101/2 1 21/2 500 4.5SI-V-8-SW-xx 751/2 361/2 243/4 191/2 251/4 12 111/2 11/2 3 600 6.8SI-V-8L-SW-xx 881/2 431/2 303/4 261/2 321/4 12 131/2 2 3 650 7.7SI-V-10-SW-xx 791/2 383/4 25 20 26 18 131/2 2 4 F 900 10.6SI-V-10L-SW-xx 921/2 453/4 31 27 33 18 131/2 2 4 F 950 11.9SI-V-12-SW-xx 831/2 413/4 241/2 153/4 253/4 18 141/2 21/2 4 F 1,125 15.9SI-V-12L-SW-xx 1071/2 533/4 361/2 273/4 373/4 18 141/2 21/2 4 F 1,175 19.2SI-V-14-SW-xx 981/2 483/4 301/2 181/2 301/2 18 161/4 3 5 F 1,700 22.0SI-V-14L-SW-xx 1281/2 633/4 451/2 331/2 451/2 18 161/4 3 5 F 1,800 27.5SI-V-16-SW-xx 122 603/4 401/2 261/2 40 18 18 3 6 F 2,200 34.2SI-V-16L-SW-xx 150 743/4 541/2 401/2 54 18 18 3 6 F 2,350 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

VERTICALSINGLE-WALL

STEAM TO WATER

Mini-Pack™ Water Heaters

‘L’HOT WATER

OUTLET

INLETSTEAM

A

C

B

D

J

G

E

1" FPT

HOT WATEREVACUATIONTO SAFE AREA

K

Dimensions - Vertical Single-Wall Steam-to-Water

A

C

B

‘L’HOT WATEROULET

H

3/4" BOLT HOLE

D

E

J

G

‘K’ FPTCONDENSATE

INLETSTEAM

MODELA B C D E G H J K L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-4-SW-xx 561/4 131/4 30 31/2 131/2 71/2 401/2 91/4 3/4 2 300 2.1SI-H-5-SW-xx 491/4 131/4 23 31/2 143/4 83/4 331/2 10 1 21/2 350 2.5SI-H-6-SW-xx 573/4 133/4 313/4 31/2 151/4 93/4 413/4 101/2 1 21/2 450 4.5SI-H-8-SW-xx 541/4 151/4 243/4 4 181/4 113/4 363/4 111/2 11/2 3 550 6.8SI-H-8L-SW-xx 601/4 151/4 303/4 4 181/4 113/4 423/4 111/2 11/2 3 600 7.7SI-H-10-SW-xx 571/2 163/4 25 41/4 22 141/2 371/2 131/2 2 4 F 850 10.6SI-H-10L-SW-xx 631/2 163/4 31 41/2 22 141/2 431/2 131/2 2 4 F 900 11.9SI-H-12-SW-xx 641/2 23 241/2 7 261/2 161/2 383/4 141/2 21/2 4 F 1,075 15.9SI-H-12L-SW-xx 761/2 23 361/2 7 261/2 161/2 503/4 141/2 21/2 4 F 1,125 19.2SI-H-14-SW-xx 761/4 263/4 301/2 81/2 26 181/2 461/4 151/2 3 5 F 1,650 22.0SI-H-14L-SW-xx 911/4 263/4 451/2 81/2 26 181/2 611/4 151/2 3 5 F 1,750 27.5SI-H-16-SW-xx 913/4 303/4 401/2 10 27 20 583/4 161/4 3 6 F 2,150 34.2SI-H-16L-SW-xx 1053/4 303/4 541/2 10 27 20 723/4 161/4 3 6 F 2,300 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

HORIZONTALSINGLE-WALL

STEAM TO WATER

Dimensions - Horizontal Single-Wall Steam-to-Water

14

A.S.M.E.

A.S.M.E.

L

Page 5: Mini-Packs Excerpt

MODELA B C D E G J K L1 SHIPPING

WEIGHT(LBS.)

WATER VOL. IN

SHELL (GAL.)SI-V-5-DW-SP 981/4 271/2 55 12 163/4 12 10 1 21/2 400 4.7SI-V-6-DW-SP 102 303/4 541/2 14 191/4 12 101/2 1 21/2 500 6.9SI-V-8-DW-SP 983/4 311/2 551/4 131/4 19 12 111/2 11/2 3 600 11.8SI-V-10-DW-SP 1051/2 353/4 561/2 151/2 213/4 18 131/2 2 4 F 1,000 18.5SI-V-12-DW-SP 1101/2 391/4 55 113/4 213/4 18 141/2 21/2 4 F 1,300 26.5SI-V-14-DW-SP 122 413/4 63 93/4 213/4 18 161/4 3 5 F 1,900 34.1SI-V-16-DW-SP 1281/2 44 663/4 83/4 221/4 18 18 3 6 F 2,450 46.9

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

VERTICALDOUBLE-WALL

STEAM TO WATER

‘L’HOT WATER

OUTLET

INLETSTEAM

A

C

B

D

J

G

E

1" FPT

HOT WATEREVACUATIONTO SAFE AREA

L

K

Dimensions - Vertical Double-Wall Steam-to-Water

15

MODELA B C D E G H J K L1 SHIPPING

WEIGHT(LBS.)

WATERVOL.IN

SHELL (GAL.)SI-H-5-DW-SP 85 141/4 55 31/2 143/4 83/4 66 10 1 21/2 435 4.7SI-H-6-DW-SP 861/4 15 541/2 31/2 151/4 93/4 67 101/2 1 21/2 535 6.9SI-H-8-DW-SP 833/4 161/2 551/4 4 181/4 113/4 68 111/2 11/2 3 635 11.8SI-H-10-DW-SP 88 181/4 561/2 41/8 22 141/2 691/2 131/2 2 4 F 950 18.5SI-H-12-DW-SP 953/4 241/2 55 7 261/2 161/2 703/4 141/2 2 4 F 1,200 26.5SI-H-14-DW-SP 109 281/2 63 81/2 251/4 181/2 791/2 151/2 2 5 F 1,750 34.1SI-H-16-DW-SP 1161/2 321/2 66 10 27 20 831/2 161/4 2 6 F 2,250 46.9

HORIZONTALDOUBLE-WALL

STEAM TO WATER

A

C

B

‘L’HOT WATER

OULET

H

3/4" BOLT HOLE

D

J

G

‘K’ FPTCONDENSATE

INLETSTEAM

Dimensions - Horizontal Double-Wall Steam-to-Water

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

A.S.M.E.

INLETSTEAM

E

A.S.M.E.

Series

Page 6: Mini-Packs Excerpt

www.ajaxboiler.com

VERTICALSINGLE-WALL

WATER TO WATER

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

MODELA B C E G J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-V-4-SW-xx 83 40 30 301/4 12 91/4 2 300 2.1SI-V-5-SW-xx 693/4 333/4 23 24 12 10 21/2 350 2.5SI-V-6-SW-xx 86 42 313/4 311/2 12 101/2 21/2 400 4.5SI-V-8-SW-xx 751/2 361/2 243/4 251/4 12 111/2 3 500 6.8SI-V-8L-SW-xx 1141/2 561/2 433/4 321/4 12 111/2 3 550 7.7SI-V-10-SW-xx 791/2 383/4 25 271/2 18 131/2 4 F 850 10.6SI-V-10L-SW-xx 921/2 453/4 31 341/2 18 131/2 4 F 900 11.9SI-V-12-SW-xx 831/2 413/4 241/2 283/4 18 141/2 4 F 1,075 15.9SI-V-12L-SW-xx 1071/2 533/4 361/2 403/4 18 141/2 4 F 1,200 19.2SI-V-14-SW-xx 90 483/4 301/2 34 18 161/4 5 F 1,550 22.0SI-V-14L-SW-xx 1281/2 633/4 451/2 49 18 161/4 5 F 1,850 27.5SI-V-16-SW-xx 122 603/4 401/2 291/2 18 161/4 6 F 2,125 34.2SI-V-16L-SW-xx 150 783/4 541/2 521/2 18 161/4 6 F 2,350 47.0

Mini-Pack™ Water Heaters

Dimensions - Vertical Single-Wall Water-to-Water

HORIZONTALSINGLE-WALL

WATER TO WATER

E

BOILER WATEROUTLET

BOILER WATERINTLET

G

‘L’COLDWATERINLET

J

3/4" BOLT HOLE

‘L’HOT WATEROUTLET

D

B

C

A

H

E

BOILER WATEROUTLET

BOILER WATERINTLET

G

J B

C

A

HOT WATEREVACUATIONTO SAFE AREA

‘L’COLD

WATERINLET

HOT WATEROUTLET

‘L’

1" FPT

16

MODELA B C D E G H J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-4-SW-xx 561/4 131/4 30 31/2 131/2 241/2 401/2 91/4 2 275 2.1SI-H-5-SW-xx 491/4 131/4 23 31/2 143/4 241/2 331/2 10 21/2 300 2.5SI-H-6-SW-xx 573/4 133/4 313/4 31/2 151/4 241/2 413/4 101/2 21/2 350 4.5SI-H-8-SW-xx 541/4 151/4 243/4 4 181/4 28 363/4 111/2 3 450 6.8SI-H-8L-SW-xx 601/4 151/4 303/4 4 181/4 28 423/4 111/2 3 500 7.7SI-H-10-SW-xx 553/4 151/4 25 4 22 31 371/2 131/2 4 F 800 10.6SI-H-10L-SW-xx 613/4 151/4 31 4 22 31 431/2 131/2 4 F 850 11.9SI-H-12-SW-xx 581/2 17 241/2 4 261/2 34 383/4 141/2 4 F 1,025 15.9SI-H-12L-SW-xx 701/2 17 361/2 4 261/2 34 503/4 141/2 4 F 1,150 19.2SI-H-14-SW-xx 703/4 21 301/2 61/2 251/4 35 461/4 151/2 5 F 1,500 22.0SI-H-14L-SW-xx 853/4 21 451/2 61/2 251/4 35 611/4 151/2 5 F 1,800 27.5SI-H-16-SW-xx 841/4 23 401/2 63/4 27 36 583/4 161/4 6 F 2,075 34.2SI-H-16L-SW-xx 981/4 23 541/2 63/4 27 36 723/4 161/4 6 F 2,300 47.0

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

Dimensions - Horizontal Single-Wall Water-to-Water

A.S.M.E.

A.S.M.E.

Page 7: Mini-Packs Excerpt

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

MODELA B C E G J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-V-5-DW-xx 981/2 271/2 55 163/4 12 10 21/2 425 4.7SI-V-6-DW-xx 102 303/4 541/2 191/4 12 101/2 21/2 500 6.9SI-V-8-DW-xx 983/4 311/2 551/4 19 12 111/2 3 700 11.8SI-V-10-DW-xx 1051/2 353/4 561/2 231/4 18 131/2 4 F 1,100 18.5SI-V-12-DW-xx 1101/2 391/4 55 243/4 18 141/2 4 F 1,425 26.5SI-V-14-DW-xx 122 413/4 63 251/4 18 161/4 5 F 1,975 34.1SI-V-16-DW-xx 1281/2 44 663/4 293/4 8 18 6 F 2,475 46.9

VERTICALDOUBLE-WALL

WATER TO WATER

Dimensions - Vertical Double-Wall Water-to-Water

HORIZONTALDOUBLE-WALL

WATER TO WATER

E

BOILER WATER

OUTLET

BOILER WATERINLET

G

COLDWATERINLET ‘L’

J

3/4" BOLT HOLE

‘L’ HOT WATER

OUTLETFAR SIDE

D

B

C

A

H

MODELA B C D E G H J L1 SHIPPING

WEIGHT(LBS.)

WATERVOL. IN

SHELL (GAL.)SI-H-5-DW-xx 85 141/4 55 31/2 143/4 241/2 66 10 21/2 375 4.7SI-H-6-DW-xx 861/4 15 541/2 31/2 151/4 241/2 67 101/2 21/2 450 6.9SI-H-8-DW-xx 833/4 161/2 551/4 4 181/4 28 68 111/2 3 650 11.8SI-H-10-DW-xx 861/4 161/2 561/2 4 22 31 691/2 131/2 4 F 1,050 18.5SI-H-12-DW-xx 893/4 181/2 55 4 261/2 34 703/4 141/2 4 F 1,375 26.5SI-H-14-DW-xx 1033/4 231/2 63 61/2 251/4 35 791/2 151/2 5 F 1,925 34.1SI-H-16-DW-xx 1091/2 251/2 663/4 63/4 27 36 831/2 161/4 6 F 2,425 46.9

All dimensions in inches. Dimensions are subject to change.1 Connections 4" IPS and above 150# ANSI FLG

Dimensions - Horizontal Double-Wall Water-to-Water

BOILER WATEROUTLET

BOILER WATERINTLET

G

J B

C

A

HOT WATER EVACUATION TO SAFE AREA

‘L’COLD

WATERINLET

‘L’HOT

WATEROUTLET

E

1"FPT

17

A.S.M.E.

A.S.M.E.

Series

Page 8: Mini-Packs Excerpt

35

Double-Wall Tube BundlesMeets Uniform Plumbing Code requirements for heating potable water. Prevents cross-contamination. Tested and certifi ed by the City of Los Angeles Testing Laboratory.

• Easy Inspections and low maintenance• Fully visible, 360º vented leak detection between tubesheets.• Bolting and gaskets for potable water and heating medium are completely independent.• Individual tube access for easy maintenance.• Optional: Tubesheet contacting potable water is solid 304 stainless steel.• Used to upgrade present single-wall tube bundles.• Available in storage semi-instantaneous water heaters and exchangers with copper or

cupro-nickel tubes and carbon steel or stainless steel tube sheets (Up to 400 PSIG with cupro-nickel tubes)

Double-Wall Protection PerformanceTube failure can be caused by corrosion, erosion, and vibration, and can result in the contamination of the domestic water system to be contaminated by a heating medium such as steam, hydronic water, glycol solution, etc. There is no practical way to have the heating medium sterile or free from harmful treatment compounds or corrosion by-products. A low pressure heating medium circuit does not ensure contamination protection of indirect, single-wall water heaters. Whether they are shell and tube, shell and coil, plate and frame, or any other type, all consist of relatively thin wall heat transfer surface separating the heating medium from the domestic water system. Therefore, the potential for cross contamination is real and in some instances contamination has occured. Several states and cities are now insisting on double-wall vented construction in all direct type domestic water heaters. Plumbing codes have also been re-written to include double-wall protection. Ajax Boiler has developed the most practical, “state-of-the-art” double tube wall heaters to preclude any possibility of contaminating the domestic water system.

The Ace Series double-wall is the most positive form of double tube wall construction available, with no sacrifi ce in water heater effeciency or performance over a single tube wall heater.

The heat transfer surface is 5/8" O.D. x .042" thick inner wall and 3/4" O.D. x .042" outer wall SB-75 copper tubing. The .042" dimensions are actual net tube wall thicknesses which equal .084" thickness of total wall separation. This is more than twice the thickness of many single wall water heater products. Both inside and outside tube surfaces are smooth (prime) with no fins or surface irregularities to promote scale formation or corrosion attack.

Double-wall tubing has a similar overall heat conductivity as a single wall tube of equivalent wall thickness. The heat transfer capabilities were determined by actual tests conducted at the Ajax Boiler facilities. Each tube has multiple parallel and continuous vent paths.

Page 9: Mini-Packs Excerpt

www.ajaxboiler.com36

The Ajax Boiler Factory limited warranty provides assurance that all products are free from manufactures defects at the time of shipment and meet specifi cations and performance described in the product literature. It is important to understand the difference between a factory warranty and an installed warranty. There are many factors that can occur to the products after they are shipped that the company has no control over and cannot fully verify. These include: 1. Hidden damage during the shipping 2. Handling damage 3. Damage during storage 4. Installation conditions 5. Other unknown variables in the system design, operations, maintenance, pulsation and vibrations.

The installed warranty is the responsibility of the architect, specifying engineer, contractor and or owner who jointly have control over the application, installation, location, operating and maintenance conditions. The AJAX BOILER INC. warranty excludes extended liabilities. Extended liability typically occurs when products are installed without proper drainage, fl ooding containment or when safety devices are not tested and repaired or replaced when needed. Product problems are often caused by the condition of the water, the lack of water treatment and or the improper treatment of the water, insuffi cient combustion air, improper draft conditions, bolts not re-tightened, pipes not fl ushed and cleaned of oil, metal chips, rags, vibration and pulsation etc. These are installation, operating and/or maintenance conditions that are beyond the seller’s responsibility and are not covered by the factory warranty, but may be covered by the installer’s warranty. The factory warranty covering company products is based upon extensive product development and testing. Combustion products under go certifi cation testing and approvals to Underwriters Laboratory standards. Auditing of the production of combustion products is conducted by a nationally recognized testing laboratory. Pressure vessel products are designed and manufactured to American Society of Mechanical Engineering (A.S.M.E.) and National Board (NB) Design standards. Design reviews, factory product manufacturing quality inspections and testing are carried out by a third party National Board authorized inspection agency. AJAX BOILER INC. products have proven themselves in service for over 85 years which indicates that the company products perform exceedingly well when normal installation, operating

and maintenance conditions exist. The following is a review from the terms and conditions of sale. Also included in paragraph two, below, is the AJAX BOILER INC. non-conformance policy.

1. AJAX BOILER INC. warrants its products against defective material and/or workmanship only. The warranty does not apply to operational failures, electrical failures, gasket leaks, and or other malfunctions caused by improper application, installation and or maintenance.2. It is the buyer’s responsibility to inspect and accept the product, when received, as conforming to their purchase order, specifi cations and approved drawings. All claims for non-conformance, errors, shortages, etc. must be made within 10 days after receipt of the shipment.3. AJAX BOILER INC. do not provide a warranty or guarantee, express or implied, in any manner, form, usage of trade, merchant-ability or fi tness which extend beyond the product description and quotation.4. AJAX BOILER INC. liability is limited to the factory repair or replacement of warranty failures, or non-conformance, upon the return of the product to the factory.5. AJAX BOILER INC. is not liable for any direct or consequential damages.6. The AJAX BOILER INC. warranty is based upon section 23161(2) of the uniform commercial code and is printed in the terms and conditions of sale which is referenced in every quotation, on the back of sales order acknowledgements and invoices. It is legally correct and is an industry standard policy.

THERMAL SHOCK In addition to our standard one (1) year warranty against defective parts and workmanship, AJAX BOILER INC. provides the following guarantee with all commercial hot water, forced circulation, space heating boilers: AJAX BOILER INC. guarantees this new boiler pressure vessel for ten (10) years after date of installation from damage due to thermal shock. Thermal shock occurs when cold makeup water, up to 150°F less than the boiler water outlet temperature, is added directly into the boiler while the boiler is operating within the normal temperature range from 140°F to 250°F with a temperature rise from 20°F to 40°F. This guarantee shall cover damage to the boiler tubes, tube headers, and tube sheets when such damage is attributed to unequal expansion, poor circulation and/or other causes quite often described as “thermal shock.” This guarantee does not cover damage or failures that can

Page 10: Mini-Packs Excerpt

37

be attributed to corrosion, condensation, scale, boiler treatment chemicals, dirt accumulation, low water conditions, or any other abnormal operating conditions. The liability of AJAX BOILER INC. is limited solely to the replacement of the complete pressure vessel, with tubes, if found by our inspection to be damaged by thermal shock. In no event shall AJAX BOILER INC. be held liable for replacement labor charges or for freight or handling charges.

AJAX BOILER INC. provides a limited warranty on its products aganst defective material and/or workmanship only. This limited warranty is not applicable to operational failures, electrical failures, gasket leaks, wear or malfunctions caused by improper application, installation, and/or maintenance.

The following Limited Warranty periods are from date of shipment: Boiler Pressure Vessels: One year.Carbon Steel Tank and Heat Exchanger Pressure Vessels: One year.Stainless Steel Tanks: Three years.Boiler Copper Fin Coils: Three years.High Effi ciency Condensing Boiler: One Year (Three years on Coil).Single-Wall or Double-Wall Tank/Exchanger Coils: One year.Single-Wall or Double-Wall Mini-Packs: One year.Atlas Series Condensing Boiler: One Year.Linings: (Pro-Rated Warranty) Section VIII Tanks: Glass 36” dia. and above (fi ve years). Glass 30” dia. and under (one year). Cement (fi ve years). Prekrete (ten years). In Section IV Tanks: Glass (one year).Controls: Components manufactured by other than AJAX BOILER INC. such as controls, instruments, forced draft burner, etc., provided with the boilers and packaged products are not covered by the AJAX BOILER INC. Warranty. However, AJAX BOILER INC. extends to the customer the same warranty provided by the manufacturer to AJAX BOILER INC. The customer shall receive the full benefi ts of adjustments made to AJAX BOILER INC. by the manufacturer.

Any claim for adjustment under this limited warranty must be made within the warranty period. AJAX BOILER INC.’s liability shall be limited to factory repair

or, at AJAX BOILER INC.’s option, replacement of all parts which, upon test and examination by AJAX BOILER INC., prove to be defective material and or workmanship and within the above limited warranty. If required by AJAX BOILER INC., parts which are claimed to be defective must be promptly delivered to the AJAX BOILER INC. facility, transportation charges prepaid. This warranty does not cover the cost of labor, removal, or installation of the warranted item during the limited period. This warranty is limited to the above and applies only for the period set forth. AJAX BOILER INC. will not be liable for any loss damage, direct, incidental or consequential damages of any kind, whether based upon warranty, contract, negligence or strict liability and arising in connection with the sale, use or repair of the products. AJAX BOILER INC.’s maximum liability shall not exceed the contract price for the products or component claimed to be defective or unsuitable. AJAX BOILER INC. does not warrant the product’s merchantability or fi tness for any particular purpose and in no event shall be held responsible for any consequential damages.

For complete Limited Warranty conditions see Section G and H under terms and conditions of sale.

The brand and product names contained within are trademarks or registered of their respective holders. Performance, dimensions, specifi cations are effective with date of issue and are subject to change without prior notice. AJAX BOILER INC. maintains a policy of continuous improvements and therefore reserves the right to change specifi cation without notice. AJAX BOILER INC. cannot be responsible for errors in typography or photography.

Page 11: Mini-Packs Excerpt

NOTES

33

Series