mini petxina mini - holophane · 2016-09-01 · 4.3 petxina ™ mini 586 42mm side entry and 60mm...
TRANSCRIPT
petxina™ mini
4.1
petx
ina™
min
i
appl
icat
ions Petxina™ mini successfully combines a sleek
contemporary design, inspired by the natural shape
of a sea shell, with exceptional technical performance.
Combined with its complementary range of columns
and brackets, Petxina™ mini achieves dramatic night
time effects whilst, enhancing the daytime appearance
of the built environment in a variety of applications.
Superb light control ensures light pollution is limited.
Compliance with Nighttime friendly criteria combines
with the latest in lighting technology to meet the most
demanding of specifications.
Landscaped areas
Car parks
Amenity areas
Town squares
Retail parks
Entrance roads
Parks
4.2
petx
ina™
min
i
amenity
lamp types included
35W-70W Ceramic Metal Halide
45W-90W Cosmo
3000 & 4000 LED lumen package
Electronic gear/driver as standard
IP rating
IP66 (standard)
approvals
Complies with EN 62031:2009EN 62384:2007 and EN 61347-2-B:2007EN 62471:2009 and IEC/TR 6247-2:2009
To find out more please visit www.holophane.co.uk
features and benefits
Unique streamlined style
> Aesthetic appeal to complement
today’s architecture
High quality construction
> Luminaire is designed to IP66 to
ensure fully weather sealed rating
> Tool less latch ensures ease of
access into luminaire during
installation & maintenance
Limited upward light with flat glass option
> ‘Night time friendly’
Dual Light Source
> Offers the latest in electronic
ballasts to extend HID life
> LED option designed with
dedicated heat sink to maintain
product life
Single or twin mounting options
> Flexibility for different types of
application
Tool-free access to lamp and gear tray
> Easy maintenance
Petxina Mini - Flat glass (.FLG), LED .L044 version
Petxina Mini - Flat glass (.FLG), LED .L034 version
4.3
petx
ina™
min
i
586
42mm side entry and60mm post top entry as standardAvailable as 76mm with adapter
532
ϕ42
ϕ42
ϕ42
ϕ60
ϕ60
200
165
200
PEM with .76AD adapter
specification
The luminaire shall consist of curved or flat 4mm thick toughened glass lens which is housed in a shell-shaped cast aluminium LM6 body. The body shall be comprised of a door frame and canopy which houses integral control gear to suit a wide range of high intensity discharge lamps or LED module. The optical arrangement shall consist of a anodised aluminium reflector for HID or bespoke LED module with individual lenses. The door shall be secured by a corrosion resistant stainless steel latch providing tool free access for maintenance. The canopy and door shall be sealed by a silicone gasket ensuring IP66 is maintained. The luminaire complies with EN60598 with a wide range of complementary brackets and columns.
windage
CodePetxina mini 0.075 m2
weight
CodePetxina mini 8kg
light distributions
forward throw (.FW) symmetric (.SY)
Photometric data is available at www.holophane.co.uk
150mm
150mm
dimensions in mm
Note: The specifications of the Holophane luminaire and columns represents typical values. All descriptions, illustrations, drawings and specifications in the Holophane catalogue and website represent only general particulars of the goods to which they apply and shall not form part of any contract. The company reserves the right to change specifications at its discretion without prior notification or public announcement.
asymmetric (.AY)
4.4
amenity
petx
ina™
min
i
Petxina Mini - Curved glass (.CG), LED .L044 version
Petxina Mini - Curved glass (.CG), LED .L034 version
Petxina Mini - Flat glass (.FLG), HID version
Petxina Mini - Flat glass (.FLG), LED .L034 version
4.5
petx
ina™
min
i
ordering details : luminaire
accessories HEL.76AD Holophane 76mm to 60mm post top adapter
Note: Luminaries are supplied as standard for use on 240V 50Hz supply and complete with lamp. .AY is not available with .L044. *Only available with .L034 & .L044 versions
Example
Code
PEM Petxina Mini
Code Lamp Type
.45CW 45W Philips Cosmo lamp (PGZ12 base)
.60CW 60W Philips Cosmo lamp (PGZ12 base)
.90CW 90W Philips Cosmo lamp (PGZ12 base)
.35CDMTF3 35W Clear CDM-T 3000°K Metal Halide Lamp (G12 base)
.70CDMTF3 70W Clear CDM-T 3000°K Metal Halide Lamp (G12 base)
.L034 LED light engine producing c.3,000 lm with a nominal 4000°K colour temperature
.L044 LED light engine producing c.4,000 lm with a nominal 4000°K colour temperature
Code Distribution
.AY Asymmetric light distribution
.FW Forward throw light distribution (for HID only)
.SY Symmetric distribution (for LED version only)
Code Optic
.CG Curved glass
.FLG Flat glass
Code Fixing Method
.76AD 76mm retrofit adapter mounted (excludes column)
.SE42 42mm side entry mounting
.PT60 60mm post top mounting
Code Colour
.C1 Smooth White (RAL9016)
.C4 Graphite (RAL 7011)
.C6 Smooth Grey (RAL7035)
.C7 Black (RAL9005)
.C9 Metallic Silver (RAL9006)
.RAL**** RAL colour (customer choice)
Code Options
.C Enhanced paint finish
.TSZ Complete with miniature 70 lux factory
fitted photocell. (Zodion SS12)
.D2 DALI HF electronic control gear*
PEM .45CW .AY .CG .76AD .C1 .C
4.6
amenity
petx
ina™
min
i
* For 1S with PT76, 76AD must be selected on luminaire. **Please specify RAL colour reference
Example
Code
PEMB Petxina Mini Tubular Compartment Column
PEMC Pextina Mini Conical Steel Column
Code Luminaire Mounting Height
.3 3 metres
.4 4 metres
.5 5 metres
.6 6 metres
Code Brackets
.1S single head short bracket
.2S twin head long bracket
Code Bracket Type
.PT76 76mm post top mounting*
.A0 Side arm bracket suitable for 42mm entry at an angle of 0º
.A5 Side arm bracket suitable for 42mm entry at an angle of 5º
Code Column Category
.LMZ For light & medium area wind zones
.HVZ For heavy area wind zones
.HEZ For extra heavy area wind zones
Code Colour (bracket finish only)
.GV Galvanised only bracket
.GV1 Galvanised and painted white (RAL 9016)
.GV4 Galvanised and painted graphite (RAL 7011)
.GV6 Galvanised and painted grey (RAL 7035)
.GV7 Galvanised and painted black (RAL 9005)
.GV9 Galvanised and painted metallic silver (RAL 9006)
.GVRAL**** RAL Colour (customer choice)**
Code Optional Base Type
.FB1 Flange base
.FB2 Flange base
Code Optional Column Finish
.P1 Black undercoat primed
PEMB .3 .1S .PT76 .LMZ .GV1 .P1
20EN
40
EN40 Guidelines
Products affected by EN40
• Lighting columns for lanterns up to 20 metres. Post top mounted.
• Columns for side entry luminaires up to 18 metres.
Parameters of EN40
FLINTSHIRECONWY
ISLE OFANGLESEY
GWYNEDD
POWYS
THE VALE OFGLAMORGAN
NEATHPORT TALBOT
SWANSEA
CARDIFF
RHONDDA,
CYNON, TAFF
MERTHYRTYDFIL
NEWPORT
BLAENAUGWENT
CAERPHILLY
TORFAEN
MONMOUTHSHIRE
NORTHSOMERSET
BATH ANDNE SOMERSET
SOUTHGLOUCESTERSHIRE
CITY OFBRISTOL
CALDERDALE
KIRKLEES
SHEFFIELD
ROTHERHAM
BRADFORD LEEDS
YORK
BARNSLEY
WAKEFIELD
DONCASTER
NORTHLINCOLNSHIRE NORTH EAST
LINCOLNSHIRE
CITY OFKINGSTON UPON HULL
EAST RIDING OFYORKSHIRE
SOUTHAYRSHIRE
EASTAYRSHIRE
ARGYLL AND BUTE
NA H-EILEANANAN IAR
H I G H L A N DMORAY
ABERDEENCITY
ANGUSPERTH
ANDKINROSS
STIRLINGF I F E
DUNDEECITY
EASTLOTHIAN
MIDLOTHIAN
SOUTHLANARKSHIRE
CLACKMANNANSHIRE
NORTHAYRSHIRE
SCOTTISHBORDERS
ISLE OFWIGHT
SHETLAND ISLANDS
CITY OFDERBY
SWINDON
CITY OFPORTSMOUTH
CITY OFSOUTHAMPTON
BOURNEMOUTH
POOLE
RUTLAND
CITY OFLEICESTER
MILTONKEYNES
LUTON
CITY OFBRIGHTON & HOVE
CITY OFSTOKE-ON-
TRENT
CEREDIGIO
N
TORBAY
CITY OFPLYMOUTH
WESTBERKSHIRE
READING
WOKINGHAMBRACKNELL
FOREST
WINDSOR ANDMAIDENHEAD
SLOUGH
THURROCK
SOUTHEND-ON-SEA
MEDWAY
CITY OFPETERBOROUGH
COUNTY OFHEREFORDSHIRE
DE
NBIG
HSHIRE WREXHAM
TELFORDAND
WREKIN
BRID
GEN
D
BEDF
ORD
SHIR
E
CITY OFNOTTINGHAM
BLACKBURNWITH DARWEN
BLACKPOOL
ORKNEY ISLANDS
REDCAR ANDCLEVELAND
MIDDLESBROUGH
NORTH TYNESIDE
SOUTH TYNESIDE
SUNDERLAND
HARTLEPOOL
GATESHEAD
NEWCASTLEUPON TYNE
STOCKTON-ON-TEES
DARLINGTON
London
12
3
4 WESTLOTHIAN
FALKIRK
NORTH
LANARKSHIRE
5
EASTDUNBARTONSHIRE
WESTDUNBARTONSHIRE
KNOWSLEY
14 15
1617 18
19 20
ST
HELENS
WIGAN
7
6
BURY
9
8
10
11 12
13
STOCKPORTWARRINGTON
HALTON
SEFTON
Dashed linesare for clarificationpurposes only.
CARMARTHENSHIRE
PPEMBROKESHIRE
ISLES OFSCILLY
CORNWALL
DEVON
SOMERSET
DORSET
WILTSHIRE
HAMPSHIRE
WEST SUSSEX
SURREY
EAST SUSSEX
K E N T
ESSEX
SUFFOLK
NORFOLK
CAMBRIDGESHIRE
BUC
KINGHAMSHIRE
OXFORDSHIREGLOUCESTERSHIRE
SHROPSHIRE
STAFFORDSHIRE
CHESHIRE
DE
RBYSHIRE
WARWICKSHIRE
NORTH
AMPTONSHIRE
LINCOLNSHIRE
NOTT
ING
HAM
SHIR
E
NORTH YORKSHIRE
LANCASHIRE
CUMBRIA
DURHAM
NORTHUMBERLAND
LEICESTERSHIRE
WORCESTERSHIRE
A B E R D EE
NS
HI R
E
D UM F R I ES A ND G A L L O WAY
HERTFORDSHIRE
WIRRAL
1 INVERCLYDE2 RENFREWSHIRE3 EAST RENFREWSHIRE4 GLASGOW CITY5 EDINBURGH CITY6 LIVERPOOL7 BOLTON8 SALFORD9 TRAFFORD
10 ROCHDALE11 MANCHESTER12 TAMESIDE13 OLDHAM14 CITY OF WOLVERHAMPTON15 WALSALL16 SANDWELL17 DUDLEY18 BIRMINGHAM19 SOLIHULL20 COVENTRY
0 50 100 km
Boundaries revised to April 2001Crown copyright 2001
ANTRIM
DOWNARMAGHFERMANAGH
TYRONE
DERRY / LONDONDERRY
Refer to Holophane
Wind Speeds
StructuralStrength
Sites
The SitesTerrain Category I
Sea sides. At the edge of a lake with a length exposed to the wind of at least 5km. Flat, even land without obstacles.
Terrain Category II
Fenced off cultivated land, some small agricultural buildings, houses or trees.
Terrain Category III
Industrial or sub-urban zones and forests.
Terrain Category IV - Urban perimeters with at least 15% of the surface built on and/or on which the average of buildings exceed 15m.
For simplicity, Holophane have grouped lighting columns for administrative areas designated in PD 6547 table A.1, for Light Wind Zones and Medium Wind Zones under one reference, LMZ. For Heavy Wind Zones the reference is HVZ and for Extra Heavy Wind Zones the reference is HEZ.
21
EN40
Aberdeen .HVZ Aberdeenshire .HVZ Angus .HEZ Antrim .HEZ Argyll & Bute .HEZ Armagh .HEZ Bath & North East Somerset .LMZ Bedfordshire .LMZ Blackburn & Darwen .LMZ Blackpool .LMZ Blaenau Gwent .LMZ Bournemouth .LMZ Bracknell Forest .LMZ Bridgend .LMZ Brighton & Hove .LMZ Bristol .LMZBuckinghamshire .LMZCaerphilly .LMZCarmarthenshire .HEZCambridgeshire .LMZCardiff .LMZCeredigion .LMZChannel Islands .HEZCheshire .LMZClackmannanshire .HVZConwy .HEZCornwall .HVZCumbria .HEZDarlington .LMZDenbighshire .HVZDerby .LMZDerbyshire .LMZDevon .LMZDorset .LMZDown .HEZDumfries & Galloway .HVZDundee .HEZDurham .HEZEast Ayrshire .HVZEast Dunbartonshire .HVZEast Lothian .HVZEast Renfrewshire .HEZEast Riding of Yorkshire .HEZEast Sussex .LMZ
Edinburgh .HVZEssex .LMZFalkirk .HVZFermanagh .HEZFife .HVZFlintshire .LMZGlasgow .HVZGloucestershire .LMZGreater London .LMZGreater Manchester .LMZGwynedd .HEZHalton .LMZHampshire .LMZHartlepool .HVZHerefordshire .LMZHertfordshire .LMZHighland .HEZInverclyde .HEZIsle of Anglesey .LMZIsle of Man .LMZIsle of Wight .LMZIsles of Scilly .LMZKent .LMZKingston upon Hull .LMZLancashire .HVZLeeds City .HEZLeicester .LMZLeicestershire .LMZLincolnshire .LMZLondonderry .HEZLuton .LMZMedway .LMZMerseyside .LMZMerthyr Tydfil .HVZMid Lothian .HVZMiddlesbrough .HVZMilton Keynes .LMZMonmouthshire & Newport .LMZMoray .HEZNeath Port Talbot .LMZNorfolk .HEZNorth Ayrshire .HVZNorth East Lincs .LMZNorth Lanarkshire .HVZNorth Lincs .LMZNorth West Somerset .LMZNorth Yorkshire .HVZNorthamptonshire .LMZNorthumberland .LMZNottingham .LMZNottinghamshire .LMZOrkney .HEZOxfordshire .LMZ
Pembrokeshire .HVZPerth & Kinross .HVZPeterborough .LMZPlymouth .LMZPoole .LMZPortsmouth .LMZPowys .LMZReading .LMZRedcar & Cleveland .HVZRenfrewshire .HEZRhondda Cynon Taff .HVZRutland .LMZScottish Borders .HVZShropshire .HVZSlough .LMZSomerset .LMZSouth Ayrshire .HVZSouth Gloucester .LMZSouth Lanarkshire .HVZSouth Yorkshire .LMZSouthampton .LMZSouthend .LMZStaffordshire .LMZStirling .HEZStockton on Tees .LMZStoke-on-Trent .LMZSuffolk .LMZSurrey .HVZSwansea .LMZSwindon .LMZTelford and Wrekin .LMZThurrock .LMZTorbay .LMZTorfaen .LMZTyne and Wear .HEZTyrone .HEZVale of Glamorgan .LMZWarrington .LMZWarwickshire & Coventry .LMZWest Berkshire and Newbury .LMZWest Dunbartonshire .HVZWest Lothian .HVZWest Midlands .LMZWest Sussex .LMZWest Yorkshire .HEZWestern Isles .HEZWiltshire .LMZWindsor & Maidenhead .LMZWokingham .LMZWorcestershire .LMZWrexham .LMZYork .LMZ
Light & medium areasHolophane code: .LMZ
EN40 Rationalised Wind Zones (PD6547) 2004
Heavy areasHolophane code: .HVZ
Extra heavy areasHolophane code: .HEZ
22
Disclaimer
Holophane columns of 8m and above are suitable for Terrain Category II to IV, as specified in EN 40, whereas columns below 8m are suitable for location of Terrain Category III and IV only.
While it is the purchasers responsibility to specify the Terrain Category for the location of the columns, it is considered that the Terrain Categories specified above, which are recommended in PD 6547 (guidance on the use of EN 40), will be suitable for the vast majority of lighting columns installed within the UK.
It is of course possible that a small number of columns will be installed in more severe Terrain Categories than those above. Such locations include coastal sites (within 5Km of the coast), columns mounted on elevated locations such as bridges or installed on sites above 250m altitude. Locations with known local wind funnelling also need to be considered as a special case. Where special conditions exist or there are concerns that columns designed for the standard Terrain Categories detailed above may not be suitable, please contact your local Holophane Sales Engineering who will pass your specific site details to our Unique Solutions Department. The information required to ensure a suitable column is specified for your particular set of circumstances is.
• Mounting height.
• Column type e.g. Conical
• Number and type of luminaire.
• Bracket type if appropriate
• Administrative area of installation.
• Altitude if above 250m.
• Details of site including any relevant or special conditions.
• Mounting method - direct embedment or flange base.
The addition of locally applied signs and banners can significantly increase the load on the column. In such cases, a higher specification column is likely to be required. Please give your local Holophane Engineer details of the additional loading you wish to apply, i.e. maximum area and mounting height. In the case of light strings (Christmas lights) the weight/m, distance of the span and the minimum “centre sag” dimension you will be installing.
Under no circumstances should lighting columns be drilled or additional items welded to columns as this will locally reduce the strength of the column and may cause a significant safety hazard.