mira mode shower and bath fittings - kohler€¦ · mira mode shower and bath fittings if you...

32
Please leave these instructions with the user Installation Guide Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then please refer to the Fault Diagnosis section, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found in the back of this guide.

Upload: others

Post on 26-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

1 1287823-W2-B

Please leave these instructions with the userInstallation Guide

Mira Mode Shower and Bath Fittings

If you experience any difficulty with the installation or operation of your new shower, then please refer to the Fault Diagnosis section, before contacting Kohler Mira Ltd.

Our telephone and fax numbers can be found in the back of this guide.

Page 2: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

21287823-W2-B

Page 3: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

3 1287823-W2-B

Important Information

1. Installation of the shower fittings must be carried out in accordance with these instructions by qualified, competent personnel.

2. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company.

3. Install the shower fittings over a water catchment area and position so that the water discharges down the centre line of the bath, or across the opening of a shower cubicle. The handset should direct the water away from the shower unit.

4. Do not fit any form of flow control in the outlet pipe work if the shower fittings are installed in conjunction with a product that requires the fittings to act as a vent (e.g. an electric shower).

5. Do not use excessive force when making connections.6. Avoid layouts where the shower hose will be sharply kinked. This

may reduce the life of the hose. 7. Special consideration should be given to the fixing arrangements

when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative proprietary cavity fixings, or choose other options, however, these methods of fixing are beyond the scope of this guide.

8. The position of the shower fittings must provide a minimum air gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin. There must be a minimum distance of 30 mm between the showerhead and the spill over lever of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk.

Products manufactured by Kohler Mira Ltd are designed to be safe, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.Follow all warnings, cautions and instructions contained in this guide, and on, or inside the product. Failure to follow the instructions provided with this product will invalidate the guarantee.

Page 4: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

41287823-W2-B

Note! There will be occasions when the hose retaining ring will not provide a suitable solution for Fluid Category 3 installations. In these instances an outlet double checkvalve must be fitted, this will increase the required supply pressure typically by 10 kPa (0.1 bar).Double checkvalves fitted in the inlet supply to the appliance cause a pressure build up, which affects the maximum static inlet pressure for the appliance and must not be fitted. For Fluid Category 5, double checkvalves are not suitable.

Hose Retaining Ring Fitted and Shower Fittings Fixed at a Suitable Height Preventing Dirty Water Backflow

Bath or Shower Tray FC3

25 mm Min.

25 mm Min.

Toilet or Bidet FC5

Hand Basin FC3

Zone of Backflow

Risk

30 mmMin.

The Mira Mode has been designed for domestic use only, it is not recommended for Commercial or Healthcare use.For domestic installations, Kohler Mira Limited, guarantee the Mira Mode against any defect in materials or workmanship for a period of one year from the date of purchase.

Guarantee

SpecificationsMinimum maintained water pressure 0.1 bar (10 kPa)Maximum maintained water pressure 5.0 bar (500 kPa)

Page 5: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

5 1287823-W2-B

Pack ContentsCeiling Fed Shower Fittings

1 x Extension

1 x Slide Bar Assembly2 x Brackets

2 x Wall Plugs

2 x 45mm Screws

2 x Hex Screws

1 x Hex Key

2 x Spacers

2 x Rubber Washers

1 x Hose

1 x Plastic Pipe

1 x Handset

1 x Mode Component Pack

1 x Elbow Kit

1 x Ceiling Plate

2 x 70mm Screws

Page 6: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

61287823-W2-B

1 x Concealing Plate

1 x Deluge Head

1 x Elbow Kit

Ceiling-Fed Deluge Head

1 x Brazed Pipe Assembly

1 x Chrome Supply Tube

1 x Ceiling Mount Plate Assembly

Page 7: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

7 1287823-W2-B

Rear Fed Slide Bar / Showerhead

1 x Fixing Bracket

1 x Slide Bar Assembly

3 x Wall Plugs

3 x Fixing Screws

1 x Hex Key

2 x Rubber Washers

1 x Hose

1 x Cover Cap

1 x Handset

1 x Hose Retaining Ring

1 x ‘O’ Seal

1 x RAC Assembly

1 x Screw

1 x Mode Component Pack

Page 8: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

81287823-W2-B

Rear Fed Shower Arm and Deluge Head

Bath Filler

1 x Concealing Shroud

1 x Deluge Head

1 x Backplate Assembly

1 x Shower Arm

2 x Wall Plugs

2 x Fixing Screws

WasteAssembly

Hose

Clip

Clip

Filler

Page 9: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

9 1287823-W2-B

Install the Fittings

600 mm

645 mm

Max.

Fix at convenient height for all the family. Position the fittings so that water sprays down the centre of the bath, or away from the opening of a shower cubicle. Water should spray away from the interface when the showerhead is held on the slide bar.

Ceiling Fed Shower Fittings

1

Mark the position of the hole on the ceiling.Cut the hole in the ceiling to a diameter of 29 mm.

2

Mark the positions of the fixing holes for the slide bar.

50 mm

Page 10: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

101287823-W2-B

Optional Spacers (supplied)

Important! If supplied slide bar spacers are required, centre distance for ceiling hole will increase to 75 mm from wall. Use longer fixing screws if you are using the spacers.

3

Drill the fixing holes in the wall. Fit the wall plugs and the slide bar supports and install the slide bar assembly to the wall.

7.0 mm

DO NOT drill into buried cables or pipes.

Page 11: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

11 1287823-W2-B

Note! The falling supply tube may need to be shortened, use a hacksaw to shorten tube. Make sure the rough end is concealed in ceiling.

4 5

Install the screws top and bottom to secure the slide bar in position.

Install the falling supply tube.

Push and twist plastic pipe end until it “clicks” and locks in place.

Caution! Do not allow any debris to block the plastic pipe.

Elbow(Supplied)

Clip Lock

Note! If plastic pipe requires shortening, make sure there is enough length to fit elbow (supplied) or alternative push-fit/compression fitting (not supplied).

6

Feed the plastic tube up through the slide bar and into the ceiling.

a b c

Page 12: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

121287823-W2-B

Note! When shortening for use with any push-fit (e.g. John Guest) fitting, follow manufacturer’s guidelines for finishing and cleaning the pipe.

Elbow(Supplied)

7

Washer

Fit the shower hose to the end of the slide bar assembly.

8

1 min

a b

Flush the pipework.

c

WasherFlow Regulator

Fit the shower hose to the handset. Make sure that you fit the shower hose and flow regulator.

Page 13: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

13 1287823-W2-B

Ceiling-Fed Deluge HeadFix Deluge Head to the ceiling at a convenient height for all the family. Position so that water sprays down over the centre of the bath, or away from the opening of a shower cubicle. The fitting of the Deluge Head into the ceiling will be easier with two persons.When you are working within the bath or shower tray area use a towel or blanket to protect the surface from damage.

Drill 29 mm diameter hole

Caution! Drill holes in line

1

Decide on a suitable position for the Ceiling-Fed Arm avoiding cables and pipes hidden between joists or rafters. Note! A timber noggin or plywood plinth securely fixed to the joist should be used to mount the Ceiling-Fed Arm.

Timber noggin or plywood plinth

Ceiling Mount Plate

Brazed Pipe

Threaded End

32

Push the brass pipe through the ceiling mount plate then push the threaded end of the brass pipe down through the hole made in the ceiling.

Centralise the brass pipe in the hole then screw the ceiling mount plate to the wooden support.

Page 14: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

141287823-W2-B

5

Secure the brass pipe to the ceiling mount plate with the olive and 1/2” BSP nut.

Note! This is not a water tight connection, tighten sufficiently to clamp the pipe in place.

Determine the showering height

75 mm4

Offer the ceiling-fed arm to the brass pipe and determine the showering height required.

Push or pull the brass pipe using a twisting motion to adjust the height. Check the height is correct and use a 15 mm pipe cutter to cut the pipe to the desired length.

Note! Cut the brass pipe at least 75 mm above the ceiling mount plate to allow room to fit the olive, nut and elbow.

Olive

1/2” BSP Nut

Chrome Shroud

6

Offer the chrome shroud to the brass pipe and determine the length required to allow the shroud to conceal the brass pipe and protrude into the ceiling space a minimum of 15 mm. Use a pipe cutter to cut the shroud to the desired length.

Brazed Pipe

Minimum 15 mm

CeilingPlate

Threaded end of pipe

7

Push the chrome shroud into the ceiling plate then slide the chrome shroud over the threaded end of the brass pipe and up through the hole until the ceiling plate is secured in the hole and the ceiling plate is flat against the ceiling.Note! If the hole in the ceiling is oversize use silicone on the underside of the ceiling plate to retain it.

Page 15: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

15 1287823-W2-B

8

Connect the elbow (supplied) onto the end of the brass pipe. Push all parts together fully and lock elbow onto pipe using clip supplied

9

Connect the shower control outlet pipework to the elbow. Fit an isolating valve between the shower control outlet and the elbow to enable easy maintenance. (Pipe and isolating valve not supplied). Lock pipe to elbow using clip supplied. Follow manufacturers guidelines for fitting alternative push-fit connections and flexible pipework.

Deluge Head

10

Ensure pipework is thoroughly flushed through before fitting the deluge head.Screw the fixed shower head onto the brass pipe outlet.

Note! Use two suitably sized wrenches to tighten (approximately 1/4 turn).

Slide the chrome shroud down to conceal the brass pipe. Turn on the shower control and check for leaks.

Page 16: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

161287823-W2-B

Rear Fed Slide Bar / Showerhead

Fix at convenient height for all users. Position so that water sprays down the centre of the bath, or away from the opening of a shower cubicle. Water should spray away from the interface when the Showerhead is held on the Slide Bar.

Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls.

1

Using a suitable pipe cutter, trim the pipework back to the required depth from the finished wall surface. Remove all burrs and sharp edges.

31 -34 mm

90°

The right angle connector must be fitted to a waterproof, flat and even wall surface. The screws and wall plugs supplied are suitable for most solid wall installations. Alternative fixing screws for panel structures are not supplied. Use both fixing points to secure the right angle connector, be sure to use fixings appropriate for the chosen wall structure

1

1300 mm Minimum to achieve a comfortable shower height for all users

Page 17: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

17 1287823-W2-B

4 5

a

b

Mark the positions for the fixing holes for the RAC back plate.

2 3

Drill the fixing holes, fit the wall plugs and secure the backplate to the wall with two fixing screws.

8.0 mm

a

Page 18: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

181287823-W2-B

6 8

Temporarily hold the top support in position. Make sure that it is level and mark through the position of the fixing hole in the top support

Fit all the components onto the slide bar and fit the slide bar assembly in position, making sure that it locates correctly.

Fit the cover over the elbow. and tighten the screw anti-clockwise.

621 mm to top hole position

Optional Hole Position Only One Required

7.0 mm

Drill the fixing hole for the top support and fit the wall plug.

7

9

Page 19: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

19 1287823-W2-B

11

Secure the assembly in position with the screws. The top securing screw tightens Clockwise, the bottom one Anti-clockwise. Do not overtighten!

a

b

12

Fit the cap to the top of the slide bar and fit the hose to the bottom outlet.

Carefully remove the slide bar assembly and tighten the screw on the back of the top bracket to secure in position.

Refit the fit the slide bar assembly in position.

10

Top Bracket

Top Bracket

Tighten screw to secure.Note! Do not overtighten

Rear View of Top Bracket

Page 20: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

201287823-W2-B

Rear Fed Shower Arm and Deluge Head

Fix at convenient height for all users. Position so that water sprays down the centre of the bath, or away from the opening of a shower cubicle. Make sure that the water sprays away from the interface and the showerhead.

1

18 ± 2 mm

Minimum Distance to Ceiling 35 mm

3

Mark the positions of the backplate fixing holes.Caution! Be aware of hidden pipes or cables.For solid walls drill the fixing holes for the backplate with a 6 mm drill and insert the wall plugs (supplied). For other types of wall structure alternative fixings may be required (not supplied).

The outlet pipe must protrude 18 mm (± 2 mm) from the finished wall surface and a minimum 35 mm from the ceiling.

Note! Cut the pipe to the correct length and remove any burrs.

2

Page 21: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

21 1287823-W2-B

4 5

Olive

CompressionNipple

Backplate

Carefully fit the backplate over the outlet pipe and secure with the fixing screws (supplied).Caution! Take care not to damage the ‘O’ Seal in the back of the backplate.

Fit the olive and compression nipple over the outlet pipe and tighten the compression nipple.

Concealing Shroud

Compression NutOlive

Shower Arm

F i t the concea l ing shroud, the compression nut and the olive onto the shower arm.

Fit the shower arm into the compression nipple and tighten the compression nut.

Hand tighten the concealing shroud onto the backplate.

Shower Arm

Deluge Head

Flow Regulator

Do not fit deluge head until after the pipework has been fully flushed through.Screw the deluge head onto the shower arm by hand.

Note! Use a suitably sized wrench to fully tighten (approximately 1/4 turn).

6

Note! Make sure that the flow regulator is fitted in the correct orientation

Page 22: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

221287823-W2-B

Cleaning and User MaintenanceImportant! Keeping the showerhead clean and free from limescale will ensure that your shower and showerhead continue to perform to their maximum. A blocked showerhead can restrict the flow rate and may cause damage to your shower.Use your thumb or a soft cloth to wipe any limescale from the nozzles.

Unscrew the hose from the showerhead and the shower outlet.

Inspect the hose.

Inspecting the HoseImportant! The shower hose should be inspected periodically for damage or internal collapse, internal collapse can restrict the flow rate from the showerhead and may cause damage to the shower. Remove the shower hose from the shower, inspect and replace the hose if necessary.

Flow Regulation at OutletsIt is recommended that appropriate flow regulators should be fitted to the handset and deluge head.

Note! The flow regulator in the deluge head should always be greater than the handset. The customer can use a combination of the provided flow regulators to meet their system and user requirements. The flow regulators provided are as follows:

Colour Flowratewhite 12 litres/minlilac 9 litres/minpink 6 litres/min

Direction of Flow

Page 23: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

23 1287823-W2-B

Install the Bath Filler

Reversable Flat Face/Compression Fitting

Filler Body

Filler Head

Gasket

Gasket

1

Note! Make sure that you use PTFE tape when installing the filler head.

Drain Head

Gasket

Drain Body

Gasket

2

Important! When installing the Digital Mixer Valve to be used as a bath filler ensure the flow rate of the bath overflow fitted exceeds the flow rate output from the Digital Mixer Valve.

Page 24: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

241287823-W2-B

3

Fit the flexible pipe in position and secure with clips supplied.

4

Note! Waste fittings not supplied.

Page 25: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

25 1287823-W2-B

5

Connect the water supply to the bath filler using appropriate pipework (minimum 15 mm diameter).

6

Turn on the water supply and check for leaks from the waste and the bath filler connections.

5

Page 26: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

261287823-W2-B

Spare Parts

1844.022Shower Hose

1688.196Pipe Connection Pack

1688.198Wall Spacer (x2)

1688.191Upper Support

1799.015Ceiling Plate1688.195

Supply Tube

632.73Hose Washer (x2)

1841.127Clamp Bracket

1688.193Slide Bar

A

A

1688.184 Seal and Screw Pack - not illustrated1688.190 Classic Fittings Component Pack - Components identified ‘A’1874.295 Flow Regulator Component Pack - not illustrated

1688.194Chrome Supply Tube

Ceiling Fed Shower Fittings

1841.126Hose RetainingRing

A

1841.073 Handset

A

A

Page 27: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

27 1287823-W2-B

Ceiling-Fed Deluge Head

1799.012Deluge Head

1688.194Chrome Supply Tube

1799.013Brazed Pipe

1799.015Concealing Plate

1799.014Ceiling Mount Plate

1688.196 Pipe Connection Pack

1874.295 Flow Regulator Component Pack - not illustrated

Page 28: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

281287823-W2-B

Rear Fed Slide Bar / Showerhead

1844.022Shower Hose

632.73Hose Washer (x2)

1841.073 Handset

1841.127Clamp Bracket

1688.194Slide Bar

1841.126Hose RetainingRing

1841.128Upper Support

1841.129Chrome End Cap

A

A

1841.130 Component Pack - Components Identified ‘A’1874.295 Flow Regulator Component Pack - not illustrated

1841.125RAC Connector

Page 29: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

29 1287823-W2-B

Rear Fed Shower Arm and Deluge Head

Bath Filler

1799.009Rigid Arm

1799.012Deluge Head

1874.281Bath Filler

1656.132Concealing Shroud

1874.295 Flow Regulator Component Pack - not illustrated

1799.016Deluge HeadComponent Pack

1656.131Backplate Assembly

Page 30: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

301287823-W2-B

Notes

Page 31: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

31 1287823-W2-B

Notes

Page 32: Mira Mode Shower and Bath Fittings - KOHLER€¦ · Mira Mode Shower and Bath Fittings If you experience any difficulty with the installation or operation of your new shower, then

321287823-W2-B © Kohler Mira Limited, March 2017

Customer ServiceGuaranteeYour product has the benefi t of our manufacturer's 1 year guarantee which starts from date of purchase.Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by replacing parts or product as we may choose.This guarantee is in addition to your statutory rights and is subject to the following conditions : ● The product must be installed and maintained in accordance with the instructions given in this user guide. ● Replacement under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date.The guarantee does not cover: ● Non product faults (such as damage or

performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage, corrosion, chemical attack, system debris or blocked fi lters) or where no fault has been found with the product.

● Accidental or wilful damage. ● Compensation for loss of use of the product or

consequential loss of any kind. ● Damage or defects caused if the product is

repaired or modifi ed by persons not authorised by us or our appointed representative.

What to do if something goes wrongIf your product does not function correctly when you fi rst use it, check that it is installed and commissioned in accordance with the instructions in this manual.If this does not resolve the issue, contact us for help and advice.

Mira is a registered trade mark of Kohler Mira Limited.

The company reserves the right to alter product specifi cations without notice.

0844 571 5000Please note: Calls cost 7p per minute plus your phone company’s access charge.

01 531 9337

Email [email protected]

01242 282595

Email - Visitwww.mirashowers.co.uk/contactus

By Post:Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP

To Contact Us: Eire Only

To Contact Us: UK

Helpdesk ServiceContact our Customer Service Team for product advice, to purchase spare parts or accessories or to request a service visit. You can contact us via phone or e-mail - contact details below. Please provide your model name, power rating (if applicable) and date of purchase.

Mira Showers Website(www.mirashowers.co.uk)Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and popular spares, or request a service visit.

Spares and AccessoriesWe hold the largest stocks of genuine Mira spares and accessories. Contact us for a price or visit our website to purchase items from our accessory range and popular spares (Only available in the United Kingdom.)

14648