mishaal - kuwaitmeasurement.comkuwaitmeasurement.com/papers/session6/07.pdf · in 2007, mishaal...
TRANSCRIPT
MISHAAL ALANZI Gas Engineer, KOC
In 2007, Mishaal Alanzi graduated from the University of Nottingham, UK, and was awarded a Bachelor of Mechanical Engineering with Honours. Before joining KOC in 2009, Mishaal was working in Ministry of Electricity & Water (MEW) as a Mechanical Engineer for Water Projects Department for almost two years. Ever since, he’s been working as a Gas Engineer in Gas Operations Group.
Presentation Outline
2 Technology Beyond Traditional Use
3 Flow Measurement’s Challenges in KOC
4 Flow Control Switching, Check Metering & Proving Systems
5 Conclusion
1 Improvement & Expansion of KOC’s Infrastructure
Presentation Outline
2 Technology Beyond Traditional Use
3 Flow Measurement’s Challenges in KOC
4 Flow Control Switching, Check Metering & Proving Systems
5 Conclusion
1 Improvement & Expansion of KOC’s Infrastructure
Installation of Fuel Gas & Gas Oil Pipelines and Pumping
Station from MAA to Subiya & Doha
(North Kuwait)
Installation of Fuel Gas & Gas Oil Pipelines and Pumping
Station from MAA to Azzour & Shuaiba
(South Kuwait)
Fiscal Metering
Telemetry Project
Pipeline Leak
Detection System
Automation
KOC Projects
Custody-Transfer Metering Skids
Mina Al-Ahmadi (MAA)
Shuaiba
Ahmadi
Subiya
Doha
CNMC Consumer Network
Management Center
SCNMC Secondary
Consumer Network Management Center Azzour
Total Gas Delivered exceeds
4,000 MMSCFD
Ultrasonic Meters Coriolis
Meters 23 8
Major Consumers
KUWAIT
Presentation Outline
2 Technology Beyond Traditional Use
3 Flow Measurement’s Challenges in KOC
4 Flow Control Switching, Check Metering & Proving Systems
5 Conclusion
1 Improvement & Expansion of KOC’s Infrastructure
Orifice Plate and Turbine Meters were traditionally used in Kuwait Oil Company for both Gas and Liquid Metering Systems.
For example, Orifice Plate has higher pressure drop which may imply pumping or
compression costs. Turbine Meters require periodic maintenance which may result in additional cost.
The Traditional Use
23 Ultrasonic Metering Skids More than 90 Ultrasonic Flow Meters Meter Size varies from 4” up to 20” Spool-Type Ultrasonic Transit-Time differential method Multi-path Technology Applications for Fuel Gas, Gas Oil & LSFO
Ultrasonic Technology
8 Coriolis Metering Skids 16 Coriolis Flow Meters Meter Size is 8” Suitable for Mixed Liquid Service Application used for Heavy Fuel Oil
Coriolis Technology
Presentation Outline
2 Technology Beyond Traditional Use
3 Flow Measurement’s Challenges in KOC
4 Flow Control Switching, Check Metering & Proving Systems
5 Conclusion
1 Improvement & Expansion of KOC’s Infrastructure
Variations in Gas Accounting between Kuwait Oil Company (KOC) and various consumers: Power Stations of Ministry of Electricity & Water (MEW) and Small Private Users.
The Old Consumer Network required periodic High Maintenance Cost.
The obligation to meet (MEW) Power Stations Fuel Gas requirements. The ability to use Mixed Liquid Service (Crude Oil & Heavy Fuel Oil) without affecting the
Metering Accuracy. The new ongoing agreements between Kuwait Petroleum Corporation and the various Gas
Consumers in Kuwait is of high significance in terms of reliable fiscal measurement and higher accuracy.
Challenges in Fiscal Measurement
Presentation Outline
2
3
4
5
1
Technology Beyond Traditional Use
Flow Measurement’s Challenges in KOC
Flow Control Switching, Check Metering & Proving Systems
Conclusion
Improvement & Expansion of KOC’s Infrastructure
Various redundant configurations are being used (2 x 100% – 4 x 33% – 5 x 25%). Ultrasonic Metering Skids have different flow switching controls. Coriolis Metering Skids consist of only one flow switching philosophy. For example, LSFO and HFO have a redundant configuration of 2 x 100%.
Gas Oil pipelines are designed in two redundant configurations of 2 x 100% & 4 x 33%.
Fuel Gas Metering Skids utilize all of the 3 redundant configurations.
Flow Control Switching
vs.
5 Meter Runs A redundant configuration of 5 x 25% 1 Meter Run as Standby
5 Master Meters
5 Meter Runs A redundant configuration of 4 x 33% 1 Meter Run as Standby 1 Meter Run as dedicated Check Meter
Fuel Gas Metering Systems (Ultrasonic)
6 Meter Runs A redundant configuration of 5 x 25% 1 Meter Run as Standby 1 Master Meter for Checking 20” Ultrasonic Flow Meter
Fuel Gas Metering Systems (Ultrasonic)
3 Meter Runs A redundant configuration of 2 x 100%
1 Meter Run as Standby
1 Master Meter for Checking
Ultrasonic Flow Meter size is 6”
Fuel Gas Metering Systems (Ultrasonic) – Small Gas Users
HFO Metering Systems (Coriolis)
3 Meter Runs A redundant configuration of 2 x 100% 1 Meter Run as Standby 1 12” Positive Displacement Master Meter for
Checking 8” Coriolis Flow Meter
Coriolis Meter Meter Runs (A & B)
PD Meter Master Run
Presentation Outline
2 Technology Beyond Traditional Use
3 Flow Measurement’s Challenges in KOC
4 Flow Control Switching, Check Metering & Proving Systems
5 Conclusion