mitsubishi electric – gt15/gt16 – softgot-got link function – january 2010 hmi /// got1000 ///...
Embed Size (px)
TRANSCRIPT

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GOT1000 SeriesSoftGOT-GOT Link Function for GT15 and GT16 series

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT-GOT Link function – Remote Maintenance for GOTs!
• The SoftGOT-GOT link function enables GT SoftGOT1000 to connect the GOT via Ethernet.
• The function synchronizes SoftGOT1000 data with GOT project data and resource data.
• This function is available for:
(GT12 not supported yet)

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GT15/GT16
EthernetWorksite Office
SoftGOT
QPLC
Serial/BUS/Ethernet
OperationOperationinterlockinterlock
HUB HUB
Up to 99 GOTs can Up to 99 GOTs can be monitored on a be monitored on a
single PCsingle PC
Automatically upload the project data from connected GOTs
⇒ No need to create the project No need to create the project data for SoftGOT!!data for SoftGOT!!
Interlock operations with GOT and SoftGOT⇒ Prevent unexpected Prevent unexpected behaviors!!behaviors!!
Data auto Data auto uploadupload
System overview
Note! FX PLCs will be supported in one of the next development steps (no schedule yet)

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GT15/GT16
Ethernet
Worksite Office
SoftGOT
QPLC
RS232/RS422/QBUS
Read/write devicesRead/write devicesvia GOTvia GOT
1) QBUS/serial connection between GOT and 1) QBUS/serial connection between GOT and PLCPLC
SoftGOT reads/writes devices in a PLC via GOT.(Ethernet Transparent Function)
Configuration (Connection Type)

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Worksite Office
Read/write devicesRead/write devicesby directly connecting to PLCby directly connecting to PLC
2) Ethernet connection between GOT and PLC2) Ethernet connection between GOT and PLC
SoftGOT reads/writes devices in a PLC by directlyconnecting to the PLC via Ethernet, not via GOT.
Configuration (Connection Type)
GT15/GT16
RS232/RS422/QBUS
QPLC
SoftGOT

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Data Auto Data Auto Acquisition Acquisition FunctionFunction
OperationOperationInterlockInterlock
•Project data auto acquisition functionSoftGOT automatically acquires GOT screen data (project data).There is no need to create the project data for SoftGOT.
•Alarm data auto acquisition functionSoftGOT automatically acquires the alarm data of GOT. Alarms that are already restored before connecting to SoftGOT can also be viewed.
In both functions, the data stored in SoftGOT will beupdated every time the SoftGOT is started up.
•Operating authorityEither one of SoftGOT or GOT can be operable to prevent the simultaneous operation from both sides that may cause unexpected behaviors.
•Operating authority (only GOT side) A mode to make only GOT operable.
Until this mode is cancelled on a GOT, SoftGOT is notoperable.
Features

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Interlock operations with SoftGOT and GOT to prevent simultaneous operation on both sides.
GT15/GT16
Worksite Office
SoftGOT
QPLC
Operation interlockOperation interlock
Operable (withoperating authority)
×
Obtain operating authority Obtain operating authority on the operating authority on the operating authority acquisition screenacquisition screen
Operable (with operating authority)×
Not operable (no operating authority)
Operation is prohibited on Operation is prohibited on the GOT that had the GOT that had operating authority operating authority before.before.
Move Move operating operating authorityauthority
Not operable(without operating authority)
Operation Interlock – Operating Authority

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Provides a mode to operate PLC only by GOT to preventthe operating authority from being moved to SoftGOT.
Worksite OfficeOperation interlockOperation interlock
Operable×
• Not operable until GOT cancels theoperating authority priority
• SoftGOT cannot enable/cancel theoperating authority priority
The operating authority can be enabled/cancelled only on the GOT side by using switches or utility functions on the GOT.
If operating authority is enabled…If operating authority is enabled…
Not operable
Operation Interlock – Operating Authority
GT15/GT16
SoftGOT
QPLC

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Required Hardware
• All GT15 models plus GT15-J71E71-100 Ethernet module
• All GT16 models using integrated Ethernet port
• Any Q CPU (only Q!)

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Required Software
• GT Works 3 V1.10L with– GT Designer 3 V1.10L
– SoftGOT1000 3.10L

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
OS Installation -> GT15/GT16
• TransferextendedOS intoGOT!

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
GT Designer 3 Project Settings
Decide how to use the SoftGOT:1. GOT and SoftGOT should always show
the same screen: Use PLC Register (D) as Screen switching device!
2. SoftGOT should act as separate HMI showing different screens as GOT:Use GOT Register (GD) as Screen switching device!

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
• Start SoftGOT1000 and open Communication settings
QCPU serial or QBUS connection QCPU Ethernet connection

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
1. Test GOT Link
Make sure to enter the IP-addressof the GOT (not the PLC!)

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
SoftGOT settings
2. Start Monitor3. SoftGOT will
work for 2hwithout dongle!
4. GOT project will be uploadedto SoftGOTautomatically!
5. Monitoring willstart

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Good to know!

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Good to know!
• Use internal GOT devices to control operation method effectively!

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
Manual references

Mitsubishi Electric – GT15/GT16 – SoftGOT-GOT Link Function – January 2010
HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI ///
This is the first time to have This is the first time to have an Ethernet Remote an Ethernet Remote
Maintenance function in the Maintenance function in the GT15/GT16!GT15/GT16!
Let’s got out to customersLet’s got out to customerspromoting and selling it!promoting and selling it!
Thank you for your attentionThank you for your attention