model code : sb-jrv 5hp 4p lt mitsubishi … 5...ff215 215 180 j6 250 4 16 352 (329) 14.5 d la lb lc...
TRANSCRIPT
Model Code : SB-JR
LT
Type Hz V50% Load
(A) PF(%)Eff(%)
75% Load
(A) PF(%)Eff(%)
100% Load
(A) PF(%)Eff(%)Torque(kg-m)
Speed(r/min)
Torque(%)
TsIs(A)Tm
Inertia2GD
2(kg-m )
8.35
4.82
5.17
7.54
4.56
0.68
0.68
0.60
0.77
0.66
0.85
0.85
0.84
0.84
0.81
10.7
6.20
6.24
10.1
5.55
0.79
0.79
0.73
0.84
0.75
0.86
0.86
0.85
0.86
0.87
13.5
7.81
7.61
13.2
6.94
0.83
0.83
0.79
0.87
0.81
0.86
0.86
0.85
0.85
0.86
2.54
2.54
2.52
2.11
2.08
1420
1420
1430
1710
1730
266
266
316
223
298
80.0
46.2
50.5
75.0
50.1
289
289
344
247
335
0.056
60
50
220
380
415
220
440
Motor Characteristics
Circumstance Conditions
Connection & Connection Diagram
Connection
85% RH or less
o-20 ~ +40 C
No bursting / erosive gas or vapor
Less than 1,000m above sea level
Specifications subject to change without notice.
MITSUBISHI SUPER LINE SERIES INDUCTION MOTOR
Ambient Temperature
Ambient Humidity
Operating Altitude
Environment
Connection Diagram
Terminal Block
Lead Wire
Dimensions (mm)
Q
60
QK
45
LR
60
S
28 j6
T
7
U
4
W
8
Shaft End
180 j6FF215 215 16250 4 352 (329) 14.5
LCLBD LA LGLE LL* LZ
Motor
263 27 166
KB KD KL
Terminal Box
Bearing No.
Drive End Opposite
6207ZZ 6206ZZ
ApproximatedWeight (kg)
GrossWeight (kg)
Approximated PackingDimensions (LxWxH)
390 x 387 x 354
Flange
Number190
40 44
Outline DrawingD
4-LZ
A
LB
LA
A
LGKB
KD
KL
LCS
W
Drip-proof Cover
LLLRLE
Q
QK
T
U
Section A-A
Bottom viewof shaft end
IE IE
IE
141.5
* ( ) is dimension without drip-proof cover
V 5HP 4P LT
Direction of Rotation Counterclockwise (CCW)viewed from shaft-end side
Power Transmission Direct-couple orBelt Driven
Munsell N5.5 (Gray)
IEC 60034-1 & JEC-2137-2000
Voltage & FrequencyLT Type
220/380~415V 50Hz220/440V 60Hz
Drip-proof
IP 22
Specifications
3 Phase
1 (0.75)
2 Pole
80M
Output Power HP (kW)
Phase
Pole
Frame Number
Steel plate
Vertical
Class B (130°C)
Alignment
Frame Material
Connection Type
Coating Colour
Conformed Standard
Degrees of Protection
Enclosure Construction
Thermal Class
Lead Wire (6 Leads)
Direction of Rotation Counterclockwise (CCW)viewed from shaft-end side
Power Transmission Direct-couple orBelt Driven
Munsell N5.5 (Gray)
IEC 60034-1 & JEC-2137-2000
Voltage & FrequencyLT Type
220/380~415V 50Hz220/440V 60Hz
Drip-proof
IP 22
Specifications
3 Phase
5 (3.7)
4 Pole
112M
Output Power HP (kW)
Phase
Pole
Frame Number
Steel plate
Vertical
Class B (130°C)
Alignment
Frame Material
Connection Type
Coating Colour
Conformed Standard
Degrees of Protection
Enclosure Construction
Thermal Class
Lead Wire (6 Leads)