model: csd - hiweigh · 2019-09-17 · user manual 14 er1.001.018.sse chapter1 features and...
TRANSCRIPT
Model: CSD
User’s Manual
CHAPTER6 DISPLAY ILLUSTRATION
DISPLAY ILLUSTRATION REMARK〖no519〗 Withoutwirelseesignal Distancetoofar.〖SEtUP〗 Enterparametersetting 〖UAdJ 〗 Entervoltagecalibration 〖LoAd〗 Calibrationpoint 〖¯̄ ̄ ̄ ̄ 〗 Exceedhighlimit Tareweightcan’texceedfull
capacity〖 〗 Exceedlowlimit Tareweightcan’tbenegative〖-----〗 Waiting 〖Err10〗 WeightlessthanMin.Capacity Can’taccumulatethevalue〖Err11〗 Accumumatedtimesoverflow Can’taccumulateafter30times〖Err12〗 Accumulatedweightoverflow Can’taccumulateafter99999〖Err13〗 Errorinrepeataccumulation Can’taccumulateoneweight
repeatedly〖no***〗 Currentaccumulationtimes 〖H****〗 Front fourdigitof
accumulated Totalweight=frontfourdigit +rarefourdigit
〖L****〗 Rarefourdigitofaccumulated Totalweight=frontfourdigit +rarefourdigit
〖 CLr 〗 Askifyoureallywanttodeleteaccumulatedweight
Incaseerrordeletion〖noCLr〗 Giveupdeletion 〖88888〗 Confirmdeletion 〖 ¯̄ ̄ 〗 Inputvalueistoolarge Whenyouinputtareorweight
value〖 〗 Inputvalueistoosmall Whenyouinputtareorweight
value〖noACC〗 Noanyaccumulatedcontent whenyoucheckaccumulation〖-oL0- 〗 Overloadwarning Tare+Netweightexceedfull
capacity+9e〖-oL1- 〗 Overloadwarning Tare+Netweightexceedfull
capacity125%〖-Lb- 〗 Lowbatterywarning Turnoffautomaticallyone
minutelater〖U*.**〗 Thevoltageof current
battery
〖 End 〗 End whenparametersettingorcalibrationready
〖 OFF 〗 Turnoff 〖Unstb〗 InputvaluebeforeSTBlight
on
USERMANUAL 16 ER1.001.018.SSE
TABLEOFCONTENTSSAFEOPERATIONGUIDE 2CHAPTER1 FEATURESANDSPECIFICATION 3
1.Features 32.Maintechnicaldata 33.Specification 34.Appearanceillustration 45.Powersupply 4
CHAPTER2 DISPLAYANDKEY 5
1.Leddisplay 52.Keyarea 5
CHAPTER3 WIRELESSINDICATOROPERATIONGUIDE 7CHAPTER4 FUNCTIONGUIDE 8
1.Turnon/off.. 82.Zero 93.Tare 94.PeakHold 95.Accumulation 96.AccumulationSearch 97.AccumulationClear 98.BatteryVoltageCheck 109.UnitConvert 10.
CHAPTER5PARAMETERSETTING&CALIBRATION 10
1.Parametersetting 13
CHAPTER6SIGNALILLUSTRATION 14CHAPTER7TROUBLESHOOTINGGUIDE 15
USERMANUAL 1 ER1.001.018.SSE
Press【ENTER】toconfirm
〖 SP1〗 Setpoint1
Press【ENTER】toconfirm
〖1OFF〗 display1 OFF, ifitcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】 tochoose
〖1 LO〗 ChooseSetpoint 1 mode: “1 OFF” means setpoint1nofunction,“1 LO”isSetpoint1lower,“1 HI”isSetpoint1High
Press【ENTER】toconfirm
〖02000〗 display 02000, ifitcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】tosetvalue,Press【TARE】tomovedigit
〖02000〗 Set“1 LO”or“1 HI”Value.
Press【ENTER】toconfirm
〖 SP2〗 Setpoint2
Press【ENTER】toconfirm
〖2OFF〗 display 2 OFF, ifitcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】to choose
〖2 LO〗 ChooseSetpoint2mode:“2OFF”means setpoint2nofunction, “2 LO” is Set point 1 lowvalue,“2 HI”isSetpoint2HighvaluePress【TARE】toconfirm〖02000〗 display 02000, ifitcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】to setvalue,Press【TARE】tomovedigit
〖02000〗 Set“2 LO”or“2 HI”Value.
USERMANUAL 14 ER1.001.018.SSE
CHAPTER1FEATURES AND SPECIFICATION
Profile:CSD wireless load guage is an extremely well-built instrument
for industry use ,as a standard wireless tool offer universalapplications, Whether used as conventional crane weigher or tomeasure force, CSD wireless load guage is microprocessorcontrolledforprecisionaccuracy,calibration iseasierwithwirelessindicator.1.StandardFeatures: u Ruggedconstruction.u Accuracy:0.1%ofcapacityu AllfuctionsandunitsareclearlydisplayontheLCD
(withbacklighting),u Digitsare1inchhighforeasydistantviewing.u TwouserprogrammableSet-Pointcanbeusedforsafety
andwarningapplicationsorforlimitweighing.u Longbatterylifeon3standard“LR6(AA)”size
alkalinebatteries.u Allcommonlyusedinternationallyrecognizedunits
areavailable:kilograms(kg),shortTons(t)pounds(lb),Newton andkilonewton(kN)
u InfraredRemotecontroleasiertocalibration(withpassword) u Infrared Remote control with many fuctions:
“ZERO”, ”TARE”,”CLEAR”,“PEAK”,”ACCUMULATE”,”HOLD”,”UnitChange”,”VoltageCheck”and“PowerOFF”
u 4 local mechanical keys: ”ON/OFF”,”ZERO”,”PEAK” and ”UnitChange”.
u lowbatterywarnning.u RFwirelesspalmindicator
USERMANUAL 3 ER1.001.018.SSE
CHAPTER5PARAMETERSETTING&CALIBRATION.Youcanusewirelessindicatortooperateparametersettingandcabibration
1.Keyfunction:KEY FUNCTION
【TARE】 Movedigits【ZERO】 Setvalueup【MODE】 Storageandexit【ENTER】 Confirm
2.PARAMETERSETTINGOPERATION DISPLAY ILLUSTRATIONPress【MODE】key twice
〖SETUP〗 Confirm,enterparametersettingprogram
Pres【ENTER】 〖FS=06〗 display FS=06, ifitcalibrated,thescreendisplaycapacity.
Press【ZERO】tochoose
〖FS=02〗 Choose capacity ,the screen display02/03/05/06/10/15/20/30/50/60/75circularly,takecap:2000kgasexample,chooseFS=02
Press【ENTER】toconfirm
〖Id=02〗 display Id=02, ifitcalibrated,thescreendisplaycalibrateddivision.
Press【ZERO】to choose
〖Id=01〗 Choose division,thescreendisplay01/02/05/10/20circularly. 2000kgthedivisionis1kg,sochooseId=01
〖Pt=0〗 display Pt=0, if itcalibrated,thescreendisplaycalibrateddecimalposition
Press【ZERO】to choose
〖Pt=0〗 Choose decimal position, the screen display0/1/2/3 circularly, 0=xxxxx, 1=xxxx.x, 2=xxx.xx,3=xx.xxx,Cap.2000kg choosePt=0
USERMANUAL 12 ER1.001.018.SSE
4.Appearanceillustration
Cap:1-5t Cap:10-200tCAPACITY A(mm) B(mm) C(mm) D(mm) Ø(mm) H(mm) MATERIAL
1000kg 245 112 37 190 43 335 Aluminium2000kg 245 116 37 190 43 335 Aluminium3000kg 260 123 37 195 51 365 Aluminium5000kg 285 123 57 210 58 405 Aluminium10000kg 320 120 57 230 92 535 Steel15000kg 375 128 74 260 127 660 Steel20000kg 375 128 74 260 127 660 Steel30000kg 420 138 82 280 146 740 Steel50000kg 465 150 104 305 184 930 Steel100000kg 570 190 132 360 229 1230 Steel200000kg 725 265 183 440 280 1380 Steel
5.Powersupply
Battery:“LR6(AA)”sizealkalinebatteries.1.5Vⅹ3 Current: theCSD load guage average current is aboutDC35mA, 3pcs
newbatteriescanbeusedforabout40hours.wireless indicatoraveragecurrent is about DC 28mA, 4pcs new batteries can be used for about80hours
Low battery warning: When the digits flashes, it means the batteryneeds to be replaced. The CSD load guage or wireless indicator willpoweroffautomaticallyafterhalfhoursoperation.
USERMANUAL 5 ER1.001.018.SSE
4.PEAKHOLDOPERATION ILLUSTRATION
Press(PEAK)or【PEAK】 DisplayMaximumvaluePress(PEAK)or【PEAK】again readingwillresumechanging.
5.ACCUMULATION
OPERATION DISPLAY ILLUSTRATIONPress【MODE】key5timesThenPress【ENTER】Key
〖No***〗 Currentaccumulationtime〖H****〗 Frontfourdigitsoftotalvalue〖L****〗 Rearfourdigitsoftotalvalue
Afterdisplayabovecontentstwice,theCSDwillreturnautomatically.
6.ACCUMULATIONSEARCH
OPERATION DISPLAY ILLUSTRATIONPress【MODE】key6timesThenPress【ENTER】Key
〖No.***〗 Currentaccumulationtime〖*****〗 Currentweightreading〖H****〗 Frontfourdigitsoftotalvalue
〖L****〗 RearfourdigitsoftotalvaluePress【MODE】keyagain ReturnPress【TARE】and【ZERO】cancheckdifferenttimesweightandaccumulation.7.ACCUMULATIONCLEAR
OPERATION DISPLAY ILLUSTRATIONPress【MODE】key 7timesThenPress【ENTER】Key
〖 CLr〗 Askifyouwanttoclearornot〖noCLr〗 Press【MODE】keyCancelclear〖8.8.8.8.8.〗 Press【ENTER】keyConfirmclear
USERMANUAL 10 ER1.001.018.SSE
b.ZERO: WhenCSD load guage switch on with no load on the hook, but there
are smalldigitsonscreen, pressthiskeytoobtainthezeroreading.c.UNIT:Press UNIT key, the unit on LCD will circlely sequence change: “kg”→ “t”→ “lb” →“klb”→“N”→“kN”→“kg” .
d.PEAK:①.Whenweightischanging,pressthiskeywilldisplaythemaximumreading.②.Pressthiskeyagain,readingwillresumechanging.
CHAPTER3WIRELESSINDICATOROPERATIONGUIDE
①.【ZERO】a.Intestingstatus,therearesmalldigitsonscreen,pressthiskeytoobtainthezeroreading.b.InParameterSettingstatus,itUsedasscrollingup.②【TARE】a.Hang sling or container on the hook, when the reading stable,
press this key, the digitsdisplay“0”,and“N”indicatorFlash.b.Putthegoodsintocontainer,theCSDwilldisplaygoodsnetweight.c.Ifmovegoodsandcontainer,theCSDwilldisplayminusvalueof
tareweight.d.InParameterSettingstatus,itUsedasdigitsmovement。
USERMANUAL 7 ER1.001.018.SSE
RS232 PROTOCOLPort: COM1BaudRate: 4800DataBits: 8StopBits: 1 Parity: NoneASCIICodeandBinaryhybridtransmission= FLAG(1Byte) Unit SignandDecimal
F1 F2 F3 F4 F5 F6 F7 F8 (1Byte) (1Byte)preamble
STABLE
OVERLOAD
TARE
HOLD
PEAK
BETTERY
SPALARM
0x30:kg0x31:Lb0x32:N0x33:kN0x34:t
(+and-)sign:High4bitsDecimal:Low4bits
= 0:no1:Y
E
S
0:no1:Y
E
S
0:no1:Y
E
S
0:no1:Y
E
S
0:no1:Y
E
S
0:LOW
0:no1:Y
E
S
0:POSITIVE1:NEGATIVE0:NoDecimal1:1Decimal2:2Decimal3:3Decimal
TTTTT , NNNNN/PPPPP 5Byte 1Byte 5Byte Tarevalue Separate
symbleNetvalueandPeakvalue
0x30~0x39Overload:3SP+OL
0x30~0x39Overload:3SP+OL
Example:67.8kg: (F1F2F3F4F5F6F7F8)30013030363738,3030363738-68.1lb: (F1F2F3F4F5F6F7F8)31F13030363738,30303637386.78kg: (F1F2F3F4F5F6F7F8)30023030363738,3030363738
CHAPTER7 TROUBLESHOOTINGGUIDEPROBLEM POSSIBLECAUSE SOUTIONNodisplay Defectivebattery Replace
Defectivebutton RequiresauthorizedservicePower button not
properlydepressedPress ON/OFF key firmly inthreeseconds
Digitsflash Lowbattery ChangenewbatteryDisplaydoesn’trespondtoloadchanges
FaultyloadcellorPCB RequiresauthorizedserviceOutofcalibration Re-calibration
DisplayexperiencesexcessiveZerodriftbetweenweighment
CSDdonotstabilizeafterturningon
Afterturningon,heating3-5
minutes.
Displayedweightshowslargeerror
CSDnotZeroedbeforeapplyingweight
DepressZERObeforeapplyingweight
Requiresrecalibration SeecalibrationKg/lbwrongselecion Seeoperation
Wirelessdistanceshortened
Wirelessindicator’sbatteryislow
Replacebattery.
NOTE:IfyouturnofftheCSD,immediatelyturnonit,sometime
itwilldisply〖-oL1- 〗thoughitwithoutanyhanging.Justturnoff CSDandwaitingfewminutesthenturnonagain.
USERMANUAL 17 ER1.001.018.SSE
SAFEOPERATIONGUIDE:1. DonotoverloadthisCSDloadguage.
2. Donotperformoverheadweighing.StayclearwhenCSDloadguageisin
operation
3. Donotperformweighingunderstrongwindconditionwhichmaycause
incorrectreading
4. Do not perform weighing under enviorment of temperature rapid
changesin whichmaycauseincorrectreading
5. Donotattempt toopen thisCSD loadguage,nouserserviceableparts
inside.
6. Donotremovewireropestopperfromhook.Forsafetyreasons,always
applyit.
7. Removeallloadsfromshackleorhookwhennotinused.
8. Beforeweighing, checkandmakesure thatallhanging /load- receiving
elements/devicesareingoodcondition.
9. Checkhook, shackle, safetypins, and latchesperiodically. Contact your
dealerforpartsreplacementincasedefect,deformorwearingisfound.
10. AlwaysliftloadsvERically.
USERMANUAL 2 ER1.001.018.SSE
Press【ENTER】keytoconfirm
〖g= 〗 accelerationofgravity
Press【ENTER】key toconfirm
〖9.82〗NewCSD,the screendisplay9.7930,ifCSDbecalibrated,thescreendisplaycalibratedareavalue.usercanchangeittolocalvalue,press【MODE】keytoshiftdigit,Press【ENTER】keytochangevalue.Thelimitedvalueis9.783-9.832
Press【MODE】key 〖 End〗 Confirmaboveparametersetting,Exitparametersettingprogram.
3.calibration
OPERATION DISPLAY ILLUSTRATIONToconfirm 〖 0〗TakeCap:1000kg CSDasexample,pay
attention that the screen display〖 0〗afterhangingtareweight,youcanhangtareweightatfirst,thenturnon..Press【MODE】key
8times, 〖CLIbr〗 AccesscalibrationStatus
Press【ENTER】key 〖CAL1〗 Onepointcalibration
Press【ENTER】key 〖CALSP〗 ZeropointcalibrationPress【ENTER】key 〖LoAd〗 Hangingstandardweight2000kg
WaitinguntilSTBsignalonscreenPress【ENTER】key 〖01000〗Displaycapacityyouchoose when
parametersetting,andfirstdigitflash,Dowaituntil“STB”signaldisplayonscreen.
Press【MODE】key tostorage
〖-------〗 Confirm
〖 -oL-〗 〖End〗 〖1000.0〗Press【TARE】key toShiftdigit
〖 1000〗
Calibrationend
USERMANUAL 15 ER1.001.018.SSE
2.MaintechnicaldataDisplay 25mm(1’’)5digitsLCDPoweronzerorange 20%F.S.ManualZeroRange 4%F.S.TareRange 20%F.S.StableTime ≤10secondsOverloadIndication 100%F.S.+9eMax.SafetyLoad 125%F.S.UltimateLoad 400%F.S.BatteryLife ≥50hoursBatteryType “LR6(AA)”sizealkalinebatteries.1.5Vⅹ3OperatingTemp. -10℃~+40℃OperatingHumidity ≤85%RHunder20℃WirelessDistance Min.80m(default)[200m(optional)]WirelessFrequency 2.4GHz(default),433MHz,860MHz(optional)
3.Specification
ModelMax.Capacity
(kg/Ib)Min.Weigh(kg/Ib)
Division(kg/Ib)
Totaldisplaycounts(n)
CSD-01 1000/2200 10/20 0.5/1 2000
CSD-02 2000/4400 20/40 1/2 2000
CSD-03 3000/6600 20/40 1/2 3000
CSD-05 5000/11000 40/80 2/4 2500
CSD-10 10000/22000 100/200 5/10 2000
CSD-15 15000/33000 100/200 5/10 3000
CSD-20 20000/44000 200/400 10/20 2000
CSD-30 30000/66000 200/400 10/20 3000
CSD-50 50000/110000 400/800 20/40 2500
CSD-100 100000/220000 1000/2000 50/100 2000
CSD-200 200000/440000 20000/4000 100/200 2000
USERMANUAL 4 ER1.001.018.SSE
Press【ENTER】 toconfirm
〖Ab=24〗Displayzerorange,A:zerorangebyhand;B:zerorange automatically, 0~5 total 6 options: 0=0%F.S; 1=2%F.S; 2=4%F.S; 3=10%F.S; 4=20%F.S;5=50%F.SGenerallyDon’tchange thisparameter.
Press【ENTER】 toconfirm
〖Cd=11〗 New CSD, the screen display Cd=11,ifCSDcalibrated, thescreendisplaycalibratedvalue.
Press【ZERO】 toconfirm
〖Cd=11〗C:zero-tracking range,0~5 total 6 options;0=0d;1=0.5d;2=1d;3=1.5d;4=2d;5=2.5dd:display speed,0~2 total 3 options; 0=slow;1=average;2=fast;before calibration,setCd=00,aftercalibration,setCd=11again,generallychooseCd==11whenex-stock..
Press【ENTER】 toconfirm
〖LL=2〗 New CSD, the screen display LL=2,if CSDcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】 tochoose
〖LL=2〗 LL:filterparameter,0~5total6options, fromsmallesttobiggest, before calibration, setLL=0,after calibration, set LL=2 again, generallychooseLL=2whenex-stock..
Press【ENTER】 toconfirm
〖Un=0〗 New CSD,the screen display Un=0, ifCSDcalibrated,thescreendisplaycalibratedunit.
Press【ZERO】tochoose
〖Un=0〗 Chooseunit,Un=0:kg,Un=1:lb,Un=2:N,Un=3:KN,Un=4:ton,Generally,chooseUn=0whenex-stock.
Press【ENTER】 to confirm
〖OFF1〗 NewCSD,thescreen display OFF1,ifCSDcalibrated,thescreendisplaycalibratedvalue.
Press【ZERO】to choose
〖OFF2〗 Choose turn off method, 0~2total 3options; 0:turn off by hand; 1: if no operation, the screendisplay 〖 -〗after15minutes to savepower;2: ifnooperation,the screendisplay〖 -〗after 15minutes, and turn offautomatically after 60minutes. Generally,chooseOFF=2whenex-stock.
USERMANUAL 13 ER1.001.018.SSE
CHAPTER2 DISPLAY&KEY1.LCDDISPLAY
a.25mm(1’’)5digitsLCDwithallfuctionsandunits. b. :Wirelesssignal,itAppearmeanssignalstable,itdisppear
whilesignalmiss.itflashmeanssignalweak.c. : BatteryVoltage, :Full, :Low, :Emptyd. PEAK:CurrentvalueisPeakHoldvalue(maxmiumvalue).e. MEM:AppearonetimewhenParameterorcalibrationvaluestorage.long
timeappearancemeanscurrentvalueisAccumulationdata. f. STB:StableStatus.g. kN:“kilonewton”,N:“Newton”.Tarestatus“N”willflash.h. t:“ton”. i. lb:“pound”.j. kg:“kilogram”.2.KeyAreaa.ON/OFF:PowerON&PowerOFF
1.Press“ON/OFF”Key3Second,theCSDloadguageturnON. 2.InONstatus,Press“ON/OFF”Key1Second,theCSDload
guageturnOFF.
USERMANUAL 6 ER1.001.018.SSE
8.BATTERYVOLTAGE
OPERATION DISPLAY ILLUSTRATIONPress 【MODE】 key 3 times,display“dC”,press【ENTER】key.
〖U*.**〗 Display current batteryvoltage
Press【MODE】 keyagain ReturnNote:Batteryvoltagenormallybetween〖U3.50〗to〖U4.70〗,ifbelow〖U3.10〗,displaywillflash,Batteryshouldbechanged.
9.UNITCONVER
OPERATION DISPLAY ILLUSTRATIONPress【MODE】key select “UnIt”,press【ENTER】 key.
〖Un=00〗 press 【ENTER】key,Unitwillbechangedcirculate
Press【MODE】 keyagain Return
10.Returntonormaltectingstatus
OPERATION DISPLAY ILLUSTRATIONPress【MODE】keyselect “ESC”,press【ENTER】key.
〖 ESC〗 Returntonormaltestingstatus
USERMANUAL 11 ER1.001.018.SSE
③.【MODE】:Usedasfunctionselect,orcanbecombinedwithotherKeys.
④.【ENTER】:◆ Usedasfunctionselect,normallycombinedwith【MODE】Key.◆ Press【MODE】keyonce,display“OFF”,Press【ENTER】Keytorealizeremote
powerOFF。◆ Press【MODE】keytwice,display“SETUP”,Press【ENTER】KeyaccessParameter
Settingstatus.Setting finih,press【MODE】keyagainstoragedata andbacktotestmode.
◆ Press【MODE】key3 times,display“dC”,Press【ENTER】Key to inquire batteryvoltage,press【MODE】keyagainbacktotestmode.
◆ Press【MODE】key 4 times, display “Unit”, Press【ENTER】Key access unitselection.Press【ZERO】keytoselectunit,press【MODE】keyagainbacktotestmode.
◆ Press【MODE】key 5 times, display “ACCU”, Press【ENTER】Key accessAccumulationStatus,press【MODE】keyagainbacktotestmode.
◆ Press【MODE】 key6 times, display “SACCU”, Press【ENTER】Key accessAccumulationSearchStatus,press【MODE】keyagainbacktotestmode.
◆ Press【MODE】 key7times,display“clEAr”,Press【ENTER】KeyaccessAccumulationclearStatus,,display“CLr”,Press【ENTER】Keyagain,display
“noCLr”.press【MODE】keyagainbacktotestmode.◆ Press【MODE】 key8times,display“CLIBr”,Press【ENTER】Key3seconds, accesscalibrationStatus,ifpress【ENTER】keylessthan3seconds,itwillbackto testmode.
◆ Press【MODE】 key9times,display“dFuLt”,Press【ENTER】Keyand
【PEAK】Key3secondsbacktodefaultsetting.⑤.【PEAK】⑴.Whenweightischanging,pressthiskeywilldisplaythemaximumreading.⑵.Pressthiskeyagain,readingwillresumechanging.
USERMANUAL 8 ER1.001.018.SSE
CHAPTER4 CSDFUNCTIONGUIDE.
Note:( )meansthekeyonoverlay,【 】meansthekeyon wirelessindicator
1.ON/OFF ◆TURNONPress(ON/OFF)3seconds,displayasbelow:
OPERATION DISPLAY ILLUSTRATIONON/OFF 〖8.8.8.8.8.〗 Displaytwice
〖 ERT〗 Displaytwice 〖1000.0〗 Displaytwicecapacity 〖U6.XX〗 Displaycurrentbatteryvoltage 〖u 2.1〗 Displaycurrentsoftwareversion 〖-----〗 Waitingstable 〖 O〗 “STB”lighton,youcanoperatenow
◆TURNOFF 1
ManualPowerOFF Press(ON/OFF)Key3Seconds
2 RemotePowerOFF Press【MODE】Keyselect“OFF”,press【ENTER】Key3Seconds
3
AutoPowerOFF Chooseturnoffmethodwhenparametersetting,theCSDwilldisplay〖 -〗 afternooperationat15minutes to save power,and it willturnoff automaticallyafter60minutes.
2.ZERO OPERATION DISPLAY When CSD turn on,generally it
displays〖 0〗,ifdisplaysmalldigitswhennoload,pressthiskey.
1 Press(ZERO) 〖 0〗2 Press【ZERO】 3.TARE
OPERATION DISPLAY Afterturnon,hangingtareweightsuch assling,cableat first,press thiskey,“TARE” light on,then the scale willdisplaynetweightofthegoods.
1 Press【TARE】 〖 0〗
USERMANUAL 9 ER1.001.018.SSE