model f12/d toxic gas transmitter -enclosure dimensionss f12 toxic gas... · model f12/d toxic gas...
TRANSCRIPT
Model F12/D Toxic Gas Transmitter -
Page 1 of 12SS-F12_D, RM (7/19)
RS485 & JUNCTION BOX ENCLOSURE DIMENSIONS
ATI-0818a
Enclosure Dimensions
AC or DC POWERED ENCLOSURE DIMENSIONS
NOTES:
1) Enclosure Matl: Grey Polycarbonate w/S.S. Hardware Weatherproof & Corrosion resistant
2) Ratings: Nema 4X ATI-0841a
NOTES:
1) Enclosure Matl: Grey Polycarbonate w/S.S. Hardware Weatherproof & Corrosion resistant
2) Ratings: Nema 4X
3) Junction box DOES NOT contain an LCD front Panel
Model F12/D Toxic Gas Transmitter -
Page 2 of 12SS-F12_D, RM (7/19)
ENCLOSURE MOUNTING OPTIONS
ATI-0821
Enclosure Mounting
PANEL MOUNT TRANSMITTER
ATI-0842
Model F12/D Toxic Gas Transmitter -
Page 3 of 12SS-F12_D, RM (7/19)
RELAY BOARD CONNECTIONS
ATI-0847
TRANSMITTER CONNECTIONS
ATI-0844
Model F12/D Toxic Gas Transmitter -
Page 4 of 12SS-F12_D, RM (7/19)
Remote System
HEATED SENSOR WIRING DIAGRAMS
ATI-0903
Conductor ColorsT/B Pos Sensor
WiresGenerator
Wires1 WHITE2 YELLOW3 BLUE BLUE4 PURPLE WHITE5 GRAY6 GREEN7 BLACK8 BROWN BLACK9 RED RED10 ORANGE ORANGE11 WHT / BLK12 GREEN
IF USING CLOSE COUPLED HEATEDSENSOR (00-1699), WIRECOLORS WILL BE PINK
IF USING 6 FT. HEATED SENSOR(00-1878), WIRE COLORS WILLBE RED.
TRANSMITTER AC OR VDC POWERED VERSION
REMOTE SYSTEM INTERCONNECT WIRING DIAGRAM
ATI-0840
Model F12/D Toxic Gas Transmitter -
Page 5 of 12SS-F12_D, RM (7/19)
REMOTE SYSTEM (w/HEATED SENSOR) INTERCONNECT WIRING DIAGRAM (LOOP POWERED)
Remote System
TB4
TB3 141
12345678
J4a
TB6
GNL
RL3RL2RL1
234567
1
8
Junction Box
WHT (AUX -)BLK
(AUX +)WHT (HTR -)
BLK (HTR +)
TB4TB4
BLK
(G)
GRN
(Rx)
BLK
(Tx)RE
D (V
+)
Shld
234567
1
8
234567
1
8
234567
1
8
AC or 12/24 VDC Transmitter
EACH PAIR HAS A DRAINWIRE IN IT
DOES NOT MATTER WHICHDRAIN IS CONNECTED DRAIN
ON (1) END ONLY
6 COND. (3 TWISTED PAIR) CABLE(31-0068)
100 FT. MAX.
BLK
(G)
GRN
(Rx)
BLK
(Tx)RE
D (V
+)
REMOTE SYSTEM (w/HEATED SENSOR) INTERCONNECT WIRING DIAGRAM (AC OR VDC POWERED)
Model F12/D Toxic Gas Transmitter -
Page 6 of 12SS-F12_D, RM (7/19)
TRANSMITTER ACCESSORIES
ATI-0820
GAS TRANSMITTER
Model F12/D Toxic Gas Transmitter -
Page 7 of 12SS-F12_D, RM (7/19)
INSERTION SENSOR DIMENSIONS PIPE ADAPTER DIMENSIONS
Sensor Dimensions
ATI-0670ATI-0669
6ft. REMOTE SENSOR DIMENSIONS(00-1702)
ATI-1032
Model F12/D Toxic Gas Transmitter -
Page 8 of 12SS-F12_D, RM (7/19)
Dimensionals
INSERTION PROBE - OPERATING MODE
INSERTION PROBE - CALIBRATING MODE
ATI-0663
ATI-0664
Model F12/D Toxic Gas Transmitter -
Page 9 of 12SS-F12_D, RM (7/19)
INTEGRAL INSERTION PROBE - DIMENSIONS
ATI-1131
Model F12/D Toxic Gas Transmitter -
Page 10 of 12SS-F12_D, RM (7/19)
INTEGRAL INSERTION PROBE - OPERATING MODE
INSERTION PROBE - CALIBRATING MODE
ATI-1132
ATI-1133
Model F12/D Toxic Gas Transmitter -
Page 11 of 12SS-F12_D, RM (7/19)
Wiring Diagrams
INSERTION PROBE - WIRING DIAGRAM
ATI-0876
Conductor ColorsTB3 Pos Sensor Wires
1 WHITE FROM SHLD2 BROWN3 RED & (2) DRAINS4 BLACK5 YELLOW6 GREEN7 BLUE8 VIOLET9 GRAY10 WHITE11 BLK/WHT12 BLU/WHT13 N/C14 NC
Model F12/D Toxic Gas Transmitter -
Page 12 of 12SS-F12_D, RM (7/19)
6 FT. SENSOR CABLE - WIRING DIAGRAM
ATI-0890
Wiring Diagrams
Conductor ColorsTB3 Pos Sensor Wires
1 WHITE2 YELLOW3 BLUE & (2) DRAINS4 PURPLE5 GRAY6 N/C7 BLACK8 BROWN9 RED10 BLK w/ WHITE11 N/C12 GREEN13 N/C14 NC