OPERATION Tenor status indicator tower lights provide a 360° visual status signal of a machine or process that requires monitoring. The tower lights are available in one (1) through five (5) lamp models and can be supplied in steady light or flashing light with or without buzzer capability. The lights are extremely flexible since each lamp in an assembly can be wired to perform individually, based on the users' indication needs. As an example, you can wire a three lamp unit (HYTWB) to have the Green lens as a steady light, the Amber lens to be a flashing light, and the Red lens to be a flashing light with buzzer. A typical application for an indicator light wired in this manner would be a gravity feed bin that supplies compound to a press. The Green light would be ON steady when the bin was full to half empty, from half empty to empty the Amber light would flash, at empty the Red light would flash and the buzzer would sound. Tenor indicating tower lights are complete assemblies that include bulbs, pole, 90° mounting bracket and all hardware necessary for installation. The lights are ideal for indicating operating status in a wide range of process, assembly and other automatic equipment applications. SPECIFICATIONS Operating Voltage 110Vac, 24Vac, 50/60 Hz. 12Vdc, 220Vac (Special Order) Nominal Power Consumption 1 Light Models — 0.07A 2 Light Models — 0.14A 3 Light Models — 0.20A 4 Light Models — 0.27A 5 Light Models — 0.33A Bulb Ratings 5W Model HYT Status Indicator Tower Lights Bulb Flash Rate 60 Per Minute Recommended Switch Rating AC Models: 1A DC Models: 2A Mounting Horizontal or Vertical 90° Angle Bracket and Mounting Hardware Supplied. Termination Wire Leads Buzzer Decibel 60db ORDERING INFORMATION When ordering a status indicator tower light, the part number must be developed. 1. Determine if you require a steady light, flashing light capability or flashing light and buzzer capability. 2. Select operating voltage. 3. Number of lights. 4. Indicate lens color sequence. Standard Lens Sequence (From Top to Base) 1 Light: Red 2 Lights: Red, Amber 3 Lights: Red, Amber, Green 4 Lights: Red, Amber, Green, Blue 5 Lights: Red, Amber, Green, Blue, Clear Standard Lens Sequence Ordering: If you require a 110Vac, 3-light unit with flashing lamp and alarm capability, with a standard lens sequence, it would be ordered as follows: HYTWB-110-3 Special Lens Sequence Ordering: If you require a 110Vac, 3-light unit with flashing lamp and alarm capability, with a Green, Clear, Blue lens sequence, it would be ordered as follows: HYTWB-110-3GCB 86 MODEL NUMBER LENS NUMBER VOLTAGE(1) OF LIGHTS COLORS(2) 1 R= Red HYT 2 A= Amber Steady Light 110 - 110Vac 3 G= Green 4 B= Blue 5 C= Clear 1 R= Red HYTW 2 A= Amber Steady Light 110 - 110Vac 3 G= Green or Flashing 4 B= Blue Light 5 C= Clear 1 R= Red HYTB 2 A= Amber Steady Light 110 - 110Vac 3 G= Green With Buzzer 4 B= Blue 5 C= Clear 1 R= Red HYTWB 2 A= Amber Steady Light 110 - 110Vac 3 G= Green or Flashing 4 B= Blue Light W/Buzzer 5 C= Clear (1) 12Vdc, 24Vdc, 24Vac, 220Vac models available on special order. (2) From top to bottom — Standard lens sequence is; Red, Amber, Green, Blue, Clear. (3) Includes 90° mounting bracket, pole and bulbs.

Upload: voxuyen

Post on 17-Apr-2018

228 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Model HYT - instrumentation-central.cominstrumentation-central.com/documnt/TowerLights/hyt.pdfTenor HYT tower lights are available in models from one (1) to five (5) lights. The lights

OPERATIONTenor status indicator tower lights

provide a 360° visual status signal ofa machine or process that requiresmonitoring. The tower lights areavailable in one (1) through five (5)lamp models and can be supplied insteady light or flashing light with orwithout buzzer capability.

The lights are extremely flexiblesince each lamp in an assembly canbe wired to perform individually,based on the users' indication needs.As an example, you can wire a threelamp unit (HYTWB) to have theGreen lens as a steady light, theAmber lens to be a flashing light, andthe Red lens to be a flashing lightwith buzzer. A typical application foran indicator light wired in this mannerwould be a gravity feed bin thatsupplies compound to a press. TheGreen light would be ON steadywhen the bin was full to half empty,from half empty to empty the Amberlight would flash, at empty the Redlight would flash and the buzzerwould sound.

Tenor indicating tower lights arecomplete assemblies that includebulbs, pole, 90° mounting bracketand all hardware necessary forinstallation. The lights are ideal forindicating operating status in a widerange of process, assembly andother automatic equipmentapplications.

SPECIFICATIONSOperating Voltage

110Vac, 24Vac, 50/60 Hz.12Vdc, 220Vac (Special Order)

Nominal Power Consumption1 Light Models — 0.07A2 Light Models — 0.14A3 Light Models — 0.20A4 Light Models — 0.27A5 Light Models — 0.33A

Bulb Ratings5W

Model HYTStatus Indicator

Tower Lights

Bulb Flash Rate60 Per Minute

Recommended Switch RatingAC Models: 1ADC Models: 2A

MountingHorizontal or Vertical90° Angle Bracket andMounting Hardware Supplied.

TerminationWire Leads

Buzzer Decibel60db

ORDERING INFORMATIONWhen ordering a status indicator

tower light, the part number mustbe developed.

1. Determine if you require asteady light, flashing lightcapability or flashing lightand buzzer capability.

2. Select operating voltage.3. Number of lights.4. Indicate lens color sequence.

Standard Lens Sequence(From Top to Base) 1 Light: Red 2 Lights: Red, Amber 3 Lights: Red, Amber, Green 4 Lights: Red, Amber, Green, Blue 5 Lights: Red, Amber, Green, Blue, Clear

Standard Lens SequenceOrdering: If you require a 110Vac,3-light unit with flashing lamp andalarm capability, with a standard lenssequence, it would be ordered asfollows: HYTWB-110-3Special Lens Sequence Ordering:If you require a 110Vac, 3-light unitwith flashing lamp and alarmcapability, with a Green, Clear, Bluelens sequence, it would be orderedas follows: HYTWB-110-3GCB

86

MODEL NUMBER LENSNUMBER VOLTAGE(1) OF LIGHTS COLORS(2)

1 R = RedHYT 2 A = Amber

Steady Light 110 - 110Vac 3 G = Green4 B = Blue5 C = Clear

1 R = RedHYTW 2 A = Amber

Steady Light 110 - 110Vac 3 G = Greenor Flashing 4 B = Blue

Light 5 C = Clear

1 R = RedHYTB 2 A = Amber

Steady Light 110 - 110Vac 3 G = GreenWith Buzzer 4 B = Blue

5 C = Clear

1 R = RedHYTWB 2 A = Amber

Steady Light 110 - 110Vac 3 G = Greenor Flashing 4 B = Blue

Light W/Buzzer 5 C = Clear

(1)12Vdc, 24Vdc, 24Vac, 220Vac models available on special order. (2)From top to bottom — Standard lens sequence is; Red, Amber, Green, Blue, Clear. (3)Includes 90° mounting bracket, pole and bulbs.

Page 2: Model HYT - instrumentation-central.cominstrumentation-central.com/documnt/TowerLights/hyt.pdfTenor HYT tower lights are available in models from one (1) to five (5) lights. The lights

Dimensions in millimeters.For HYTWB models add 61mm to the overall height dimension.

DIMENSIONS

One LightHYT & HYTW

Two LightHYT & HYTW

Three LightHYT & HYTW

Four LightHYT & HYTW

Five LightHYT & HYTW

All light models within the HYTproduct family are supplied with a257mm (approximately 10 inches)pole and an "L" shaped mountingbracket, including nut and bolthardware.

Since some installations haveother mounting requirements,several optional alternativemounting methods are availableon Page 88 of this catalog.

Tenor HYT tower lights are available in models from one (1) to five (5) lights.The lights are supplied as complete assemblies including; bulb, pole,mounting bracket and hardware.

Mounting and Pole Length Options

The HYT series lights are extremelyapplication flexible. Individual lightscan be wired to be steady ON,flashing or with an alarm buzzer witheither steady ON or flashing light.The model on the right is equippedwith a built-in buzzer alarm.

87

Page 3: Model HYT - instrumentation-central.cominstrumentation-central.com/documnt/TowerLights/hyt.pdfTenor HYT tower lights are available in models from one (1) to five (5) lights. The lights

ORDERING INFORMATIONThe mounting options shown above provide installation flexibility which helps the user tailor an HYT indicating

light to fit their requirements. Since the standard length pole and "L" shaped bracket satisfy most requirements,the mounting options on this page must be ordered as a separate item on an order. The part number required forordering is listed on the following chart.

ST-012 Metal Mounting Base.This die cast metal base allowsall HYT family lights to be bottommounted. ST-012 replaces thestandard "L" bracket at the baseof the light.

HY-ST011 Plastic Mounting Base.This mounting base is used whenyou want to eliminate the heightprovided by the 10" pole. TheHY-ST011 base is equipped witha brass sleeve that fits into the lightcolumn base and the pole iseliminated.

HY-ST009 31.5 Inch Light Pole.This light pole allows the user toincrease the height of HYT familylights up to an additional 20 inches.The pole can be shortened orcut-off on the non-threaded endto provide optimum length.

Model ST-012Metal Mounting

Base

Model HY-ST011Plastic Mounting

Base

Model HY-ST00931.5 Inch Light

Pole

88

HYT FAMILY MOUNTING OPTIONS

PartNumber Description

HY-ST009 31.5 Inch Long Tower Light poleHY-ST011 Molded Plastic BaseST-012 Cast Metal Base