model no. - helpdesk communications ltd · 2017. 11. 3. · 5 use 8-pin terminal blocks (included)...

16
Thank you for purchasing a Panasonic Digital Super Hybrid System, Model KX-TD612. Before connecting this product, please read this manual carefully and save this manual for future use. Model No. KX-TD612 Digital Super Hybrid System Getting Started Version 3

Upload: others

Post on 30-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • Thank you for purchasing a Panasonic Digital Super Hybrid System, Model KX-TD612.Before connecting this product, please read this manual carefully and save this manualfor future use.

    Model No. KX-TD612

    Digital Super Hybrid System

    Getting Started

    Version 3

  • Contents

    Describes the included accessories and required

    tools for installation.

    Shows you how to install your system.

    Describes the basicprogramming to make/

    receive calls.

    Describes how to set the system programming by

    a personal computer (PC).

    Shows the contents of the CD-ROM.

    PreparationPage 3

    ConnectionsPage 4

    BasicProgramming

    Page 7

    PC ProgrammingPage 11

    Information onthe CD-ROM

    Page 16

    2

  • Preparation

    Check the package contents. The included materials and numbersincluded are:

    Main Unit ........... 1

    Getting Started (This manual) ........... 1

    CD-ROM (Including Manuals, etc.) ........... 1

    Template (for wall mounting) ........... 1

    Necessary user-supplied tools:Solid wire for the extension connection:

    ∗ The maximum length of the cable may vary depending on the type of the cables.Solid wire for the CO line connection:

    A Serial Interface (RS-232C) Connector for the PC connection.

    Cross-head screwdriver and flathead screwdriver.

    Electrician’s pliers.

    Wall modular jacks to connect the telephone equipment, if required.

    AC Cord [PSWAT206E] ........... 1

    Screws [PQHE5004Z] andWashers [XWG35FY] ........... 3

    10-pin Terminal Block[PSJS10S07Z] ........... 1(for external equipment)

    8-pin Terminal Blocks[PSJS08S08Z] ........... 3(for extensions)

    Pin Plugs [PQJP1E1Z] ........... 2(for paging equipment/external music source)

    Diameter of conductor ø 0.4 mm - ø 0.6 mmMaximum length of cable:

    Diameter Maximum lengthSingle Line Telephone ø 0.5 mm 620 mDigital Proprietary Telephone ø 0.5 mm 240 m

    Diameter of conductor ø 0.4 mm - ø 0.65 mmDiameter coating ø 0.66 mm - ø 1.05 mm

    Before installing your system

    3

  • Connections

    System Connection Diagram

    To ISDN (BRI) port 1 and 2 (initial)To ISDN (BRI) port 3 (additional)(Lightning Protectors)

    3 ISDN (BRI) Lines

    12 Extension lines

    Door Openers

    External Music Source

    Amplifier SpeakerPrinter or Computer

    Single Line Telephone

    Cordless Phone

    Facsimile

    DoorphonesKX-T30865

    Panasonic

    Car Batteries

    Panasonic

    Second Ringer RelayExternal Relay

    : needs optional card.

    KX-T7436

    KX-T7433

    KX-T7431 KX-T7440

    German typeDoorphone

    Voice Processing System

    POWER

    VOICE PROCESSING SYSTEM KX-TVP50

    1 Analogue CO Line (optional)

    4

  • Connections

    Use 8-pin terminal blocks (included) to connect the extension lines. Extension jacks 1 to 4 are available

    for eXtra Device Port (XDP) connection. Extension jacks 5 to 8 are only for digital proprietary telephones.

    1. While pressing down on the hole at the top of the terminal block using a small flat type screwdriver,

    insert the required telephone wire into the side hole as shown below.

    2. Attach the terminal blocks to the extension connectors on the system.

    Extension Connection

    Push to open

    Small flat type screwdriver

    Pull outto fix

    Push in thePealed Cable

    5 mm - 6 mm

    1Jack no. 2 3 4 5 6 7 8

    View of ExtensionConnector (Jack 1 – 4)

    View of ExtensionConnector (Jack 5 – 8)Jack X-1

    Jack X-2

    Jack X

    H: HighA: A-wireB: B-wireL: Low

    H: HighL: Low

    To Extensions(Jack 1 - 4(-1/-2), 5 - 8(-1) )

    L H . .L B A H . .

    • Before making the connection of the Extension Connector to the main unit,extension lines should be checked carefully. If the extension lines are connected to the main unit with those wires making a short circuit between the H-L pins or A-B pins, it may cause a malfunction of the system, or may damage the circuit of the system in the worst case.

    5

  • Connections

    1. Insert the modular plugs of the ISDN (BRI) CO line cords (8-conductor wiring) into the ISDN (BRI)

    ports 1 and 2.

    2. Connect the line cords to the terminal board or the modular jacks from the Central Office.

    CO Line Connection

    To Terminal Board or Modular Jacks from the Central Office

    ISDN (BRI)Port 1

    ISDN (BRI)Port 2

    ISDN (BRI)Port 3

    TA RA RB TB

    • When making a point-to-multipoint connection, we recommend you use connection A above because your system has a terminal register (TR) included. When making connection B, please consult your dealer to remove the TR in your system.

    TerminalEquipment 7

    TerminalEquipment 1

    To Central OfficeNetworkTermination

    A. When your system is at the end of the connection

    TerminalEquipment 7

    TerminalEquipment 1

    To Central OfficeNetworkTermination

    TR

    B. When your system is not at the end of the connection

    6

  • Basic Programming

    This chapter describes system programming necessary to enable receiving/making an outside call.

    Setting Status of Extension: ISDN (BRI) port 1, Jack 1-1 (Extension no. 201)

    The following items are required before the programmingConfirm your ISDN telephone number.

    Confirm whether your connection type is point-to-point or point-to-multipoint.

    Connect a digital proprietary telephone (DPT) with display (e.g. KX-T7436, KX-T7433, etc.) to the Jack 1-1.

    Put the overlay on the DPT connected to Jack 1-1.

    Connect the ISDN (BRI) CO line to the ISDN (BRI) port 1.

    Before Programming

    To Enter the Programming Mode

    Dial #.Press PROGRAM.

    You can change the user password.(Default: 1234) Consult your dealer.

    Dial 1234 (user password).

    PROGRAM 43# 1 2

    7

  • Basic Programming

    [001] System Speed Dialling and Intelligent Call Handling Number Set

    [623] CLIP/COLP Number Assignment for Extension

    Basic Programming

    2. Press NEXT.

    SENEXTCLRSKP+

    S P D & C H N u m b e r

    3. Dial .

    SENEXTCLRSKP+

    S P D & C H C o d ?

    1. Dial .

    SENEXTCLR

    S Y S - P G M N O ?→

    SENEXTSEL→

    5 0 0 : N o t S t o r e d

    4. Enter your phone number. 6. Press NEXT.

    SENEXTSELSKP+

    5 0 0 : 0 1 2 3 4 5 6 7 8 9

    7. Repeat steps 4 though 6until you store all of your phone number.

    SENEXTSEL→

    5 0 0 : 0 1 2 3 4 5 6 7 8 9

    5. Press .STORE

    8. Press .

    0 0 11 0 05

    END

    3. Dial .

    SENEXTCLRSKP+

    J a c k N O ?

    1. Dial .

    NEXTCLR

    S Y S - P G M N O ?→

    NEXT→

    # 1 - 1 : 5 : B I :

    SEL+ NEXTSEL→

    # 1 - 1 : 5 : A L :

    6. Press → and then enter yourISDN telephone number.

    2. Press NEXT.

    NEXTCLRSKP+

    C L I P / C O L P N O .

    NEXTSEL→

    # 1 - 1 : 0 : B I :

    4. Dial and press →.

    7. Press .STORE

    5. Keep pressing SEL+ untilAL is displayed.

    SENEXTSEL→

    # 1 - 1 : 5 : A L : 0 1 2 3 4 5

    8. Press .

    END

    26

    5

    13 11

    8

  • Basic Programming

    [423] ISDN Layer 1 Active Mode

    [424] ISDN Configuration

    3. Dial .1. Dial .

    NEXTCLR

    S Y S - P G M N O ?→

    5. Press .

    2. Press NEXT.

    NEXTCLRSKP+

    L 1 A c t i v e M o d e

    NEXTCLRSKP+

    P o r t N O ? →

    NEXTSEL+→

    # 1 : C a l l

    4. Press SEL+ and then

    press .STORE

    NEXTSEL+ →

    # 1 : P e r m a n e n t

    OR4. Press .STORE

    2 34 1

    END

    1. Dial .

    SENEXTCLR

    S Y S - P G M N O ?→

    2. Press NEXT.

    SENEXT CLRSKP+

    A c c e s s M o d e

    SENEXTCLRSKP+

    P o r t N O ? →

    NEXTSEL+ →

    # 1 : M u l t i p o i n t

    4. Press SEL+ and then

    press .STORE

    NEXTSEL+ →

    # 1 : P o i n t

    ORSTORE4. Press .

    2 1414

    5. Press .

    END

    3. Dial .11

    9

  • Basic Programming

    [425] ISDN Data Link Mode

    [426] ISDN TEI Mode

    System Restart

    After setting the system programming, restart the system. You can restart the system by turningthe Power switch “OFF” and then “ON”.

    3. Dial .1. Dial .

    NEXTCLR

    S Y S - P G M N O ?→

    5. Press .

    2. Press NEXT.

    NEXTCLRSKP+

    D a t a L i n k M o d e

    SENEXTCLRSKP+

    P o r t N O ? →

    NEXTSEL+ →

    # 1 : C a l l

    4. Press SEL+ and then

    press .STORE

    NEXTSEL+ →

    # 1 : P e r m a n e n t

    OR4. Press .STORE

    2 54

    END

    1

    NEXTCLR

    S Y S - P G M N O ?→

    2. Press NEXT.

    NEXTCLRSKP+

    T E I A s s i g n

    SENEXTCLRSKP+

    P o r t N O ? →

    NEXTSEL →

    # 1 : A u t o m a t i c

    NEXTSEL →

    # 1 : F i x 0

    ORSTORE4. Press . 4. Press and then

    press CLR, and then

    press .STORE

    SHIFT

    1. Dial .2 1614

    5. Press .

    END

    3. Dial .11

    10

  • PC Programming

    Before installing the PC programming software, be sure to read the following information.

    System Requirements:

    - Microsoft® Windows® 95, Windows 98, Windows Me, Windows 2000 or Windows NT® 4.0 or later

    - Installation of Internet Explorer 4.0 or later

    - Minimum requirements

    (for installing TD612 PC Programming software only)

    CPU: Pentium® 133 MHzRAM: 48 MBHDD: 20 MB

    - Recommendation of the ISDN cards for the remote maintenance

    FRITZ!Card PCMCIA/AVM

    FRITZ!Card PCI/AVM

    FRITZ!Card classic/AVM

    ELSA MicroLinkTM ISDN USB/ELSA

    Xircom® CreditCardTM ISDN Adapter/Intel®

    Trademarks:- Microsoft, Windows and Windows NT are either registered trademarks or trademarks of Microsoft

    Corporation in the United States and/or other countries.

    - Intel, Xircom, CreditCard, and Pentium are trademarks or registered trademarks of Intel Corporation

    or its subsidiaries in the United States and other countries.

    - AVM and FRITZ! are either registered trademarks or trademarks of AVM Computersysteme

    Vertriebs GmbH & Co. KG in the United States and/or other countries.

    - ELSA and MicroLink are either registered trademarks or trademarks of ELSA AG in the United

    States and/or other countries.

    - All other trademarks identified herein are the property of their respective owners.

    System Requirements

    11

  • PC Programming

    The PC is used for system programming. Connect the Serial Interface (RS-232C) connector of the PC

    to the Serial Interface. (A printer can be connected to the system in the same way.)

    Refer to the following charts for the pin configuration.

    PC Programming Software Installation

    You can program the system by using the set up file supplied on the CD-ROM.

    First install the PC programming software in your personal computer.

    1. After exiting all Windows programmes on your computer, insert the CD-ROM (included) into

    CD-ROM drive.

    2. Click PC Programming Software Installer on the initial screen.

    3. Click OK.

    4. Double-click Setup.exe.

    5. Follow the steps of the Wizard.

    PC Installation

    Serial Interface (RS-232C) (D-SUB, 9-pin)

    Serial Interface (RS-232C) Connector (user-supplied)

    The cables must be shielded and the maximum length is 2 m.

    PinNo.

    3265487

    SignalName

    TXDRXDDSRSG

    DTRCTSRTS

    PinNo.

    2345678

    Port on your system 9-pin port on a PC

    12

  • PC Programming

    You can set system programming by PC. An example is shown below. Please change the language on

    the window of the PC programming software when installing.

    To enter the programming mode1. Choose Connect in menu, and then click Local(RS-232C).

    2. Enter the password. You can change the password in programming [107] System Password

    (Default: 1234).

    3. Click OK.

    PC Programming

    13

  • PC Programming

    [001] System Speed Dialling and Intelligent Call Handling Number Set

    1. Click Load from PBX.

    2. Click OK to start uploading automatically.

    3. System Program Menu screen is displayed. Double-click Speed Dial & Call Handling.

    4. After entering telephone numbers and names, Click OK to store them.

    14

  • PC Programming

    To exit the programming mode

    1. After finishing all the necessary programming, click Save to PBX.

    2. Click OK to start downloading automatically.

    3. Click Exit.

    4. Click OK.

    5. Click OK.

    15

  • Information on the CD-ROM

    You can find electronic documentation for the KX-TD612 System, created in Portable Document Format (PDF), on the attached CD-ROM.Before you begin using the PDF documents, be sure to read the following information.Once you insert the KX-TD612 CD-ROM into your CD-ROM drive, an html file will start up automatically. Following the installation wizard, please select the PBX model you have, the language you want, and the manual you need. Please use Microsoft Internet Explorer version 4.0 or later. (It is not included in this CD-ROM.)

    To view the PDF documents: - Adobe® Acrobat® Reader version 4.0 or later is required. If you do not have the appropriate software, you can use the Acrobat Reader Application included in this CD-ROM.

    2000 Kyushu Matsushita Electric Co., Ltd. All Rights Reserved.C

    Printed in Japan PSQX2435XA KK1200EP2022 (E)

    System Requirements for Acrobat Reader: - i486TM, Pentium, or Pentium Pro Processor-based personal computer - Microsoft Windows 95, Windows 98 or Windows NT 4.0 service pack 3 or later - 10 MB of available RAM on Windows 95 and Windows 98 (16 MB recommended) - 16 MB of available RAM on Windows NT (24 MB recommended) - 10 MB of available hard-disk space

    Includes: - Adobe Acrobat Reader 4.0 for Microsoft Windows - Documentation The Getting Started Manual The Features Guide The User Manual The Internet Driver Installation Manual - Modem Driver File

    Copyright: - Digitised data for the documentation: Kyushu Matsushita Electric Co., Ltd. (KME) owns the data for documentation included on this CD-ROM.

    Trademarks: - Adobe and Acrobat are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. - i486 and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. - All other trademarks identified herein are the property of their respective owners.

    Installation of Acrobat Reader: Install Acrobat Reader in "Acrobat4.0installer" folder on this CD-ROM.

    ContentsPreparationConnectionsBasic ProgrammingPC ProgrammingInformation on the CD-ROM