model sr463 in-floor platform scale system899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 part no....

12
S by SR Instruments, Inc. Model SR463 In-Floor Platform Scale System OWNERS MANUAL SR Instruments, Inc. 600 Young Street, Tonawanda, NY, 14150 Tel: 888 WEIGH ME Fax: (716)693-5854 Part No. MAN463 rev: 990324

Upload: others

Post on 25-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

SSby SR Instruments, Inc.

Model SR463In-Floor Platform

Scale System

OWNERS MANUAL

SR Instruments, Inc. 600 Young Street, Tonawanda, NY, 14150Tel: 888 WEIGH ME Fax: (716)693-5854

Part No. MAN463 rev: 990324

Page 2: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

Table of Contents

SECTION IOPERATION and MAINTENANCE

System Description and Specifications Page 1

System Operation and button Functions Page 2

SECTION IITECHNICAL SERVICE INFORMATION

Calibration and Maintenance Page 4

Care and Cleaning Page 5

Schematic Diagram Page 6

Part List and Component Layout Page 7

Platform Installation Instructions Page 8

Part No. MAN463 rev: 990324

Page 3: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

MODEL SR463FLOOR SCALE SYSTEM

The SR463 is a Precision Digital Scale System specifically designed to be installedin the floor so that the weighing surface is flush. The multi-purpose design offers theversatility of being used as a Stand-On scale for weighing ambulatory patients aswell as a Wheelchair / Chair / Walker Scale for semi or non-ambulatory applications.

This Scale System employs the latest in microprocessor and load cell technologyto provide accurate and repeatable weight data. Four (4) identically matched loadcell transducers are strategically placed to ensure an accurate representation ofthe patient's weight regardless of weight distribution.

The SR463 uses 110v A.C. line power and is mounted in a recessed wall box sothe display is flush with the wall.

The Patient's weight is displayed on a user friendly 16 character dot matrix liquidcrystal display. This display uses bright green L.E.D. back lighting for superior visibilityin all lighting conditions. With the push of a button, patient weight may be viewed inboth POUNDS and KILOGRAMS with a displayed resolution of 0.1 #/Kg (100 grams).

SPECIFICATIONS

Maximum Capacity 1000 LB's / 454Kg'sPlatform Size 32" x 36"

Display Resolution 0.1 LB's / 0.1 Kg's (100 grams)Accuracy 0.1% +/- 1 digit of reading

for calibrated range.Display Type 16 character dot matrix L.C.D.

ZERO One Button Auto-TareDisplay Time Auto power-down 60 sec.

Damping Automatic digital filterPower Supply 110v A.C. 50-60 Hz

Warranty Two Years Parts and Labor

page 1

Part No. MAN463 rev: 990324

Page 4: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

MODEL SR463 FLOOR SCALE SYSTEM OPERATION

INITIALIZING THE SYSTEM ZERO:Before the patient is positioned on to the scale system you must first set the system zero.This is done as follows;

Make sure that nothing is in contact with the weighing surface so that the systemzero will be accurate. Press the "O" button. The display will indicate "HANDS OFF -PLEASE WAIT" . In a few moments the display will read - "WEIGHT = 0.0 Lb".

The patient may now be positioned on to the weighing surface

to view the weight data.

BUTTON FUNCTIONS :The "0" button is used to initialize the system zero before placing a patient on tothe scale system. Make sure that nothing is in contact with the weighing surface sothat the system zero will be accurate. Press the "O" button. The display will indicate"HANDS OFF - PLEASE WAIT" .

In a few moments the display will read - "WEIGHT = 0.0 Lb".

NOTE: When the system ZERO is reset, the LAST WEIGHT memory is also reset to zero.

If after positioning the patient on to the scale system, the display shuts off beforeyou are able to view the weight data, simply press the "WEIGH" button to WAKEthe display and view the patient's weight.

NOTE: It is recommended that you ZERO the system before each weighing to assureoptimum accuracy.

The "HOLD / RECALL" button is used to view the STORE and RECALL the lastweight stored in memory. To STORE the current weight, press the "HOLD /RECALL" . After the system has shut of you may press the "HOLD / RECALL"

button view the last stored weight.

Weight data may be viewed in either Pounds or Kilograms. Pressing the "DISPLAYMODE" button allows you to toggle the Lb and Kg display modes. Both modes willdisplay a resolution of 0.1 Lb or Kg.

Note: When the unit is first turned on the mode will default to the last mode used.

page 2

Part No. MAN463 rev: 990324

0.0

0.0

W

LbKg

Page 5: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

SECTION II

TECHNICAL SERVICE INFORMATION

For Sales, Product Informationand Technical Assistance Please Call:

1(800)654-6360

Part No. MAN463 rev: 990324

Page 6: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

SYSTEM CALIBRATION and MAINTENANCE SIMPORTANT : The following calibration procedure should only be performed by qualifiedservice personnel. The load cell, itself, has no user serviceable components and should not betampered with for any reason. Recalibration is generally not required, but may be checkedperiodically to ensure accuracy.

CALIBRATION PROCEDURE :

NOTE: Make sure that nothing is in contact with the scale system during this procedure. Be sureto remove your hands from the system when noting the displayed calibration results.

1. Press and Hold the two hidden "+" and "-" buttons above the zero button.2. The display will read "HOLD TO CAL" as the right hand digit counts down toenter the CAL MODE.3. When in the CAL MODE, press the "ZERO" button to zero the display.4. Place a known calibrated weight on to the weighing surface and compare it tothe displayed reading.5. Use the hidden "ADJUST" buttons to make "+" (left) and "-" (right) correctionsto the displayed weight. The displayed value should be within 0.1% of the calibratedweight plus or minus 1 digit of reading.

When adjustments are completed:Press the hidden "WEIGH" button to ABORT your changes and exit the CAL mode.

----- OR -----Press the "HOLD / RECALL" button to SAVE all changes and exit the CAL mode.

CALIBRATION TOLERANCE TABLELOW APPLIED HIGHLIMIT LOAD LIMIT99.9 100.0 100.1199.8 200.0 200.2299.7 300.0 300.3399.6 400.0 400.4499.5 500.0 500.5599.4 600.0 600.6699.3 700.0 700.0799.2 800.0 800.8

899.1 900.0 900.9999.0 1000.0 1001.0

page 4

Part No. MAN463 rev: 990324

HOLD /MODERECALL

DISPLAYZERO0

WEIGH

0.0 WLb

Kg

HIDDEN BUTTONS FOR

+ -CAL MODE

Page 7: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

SYSTEM CARE and CLEANINGCLEANING and DISINFECTING:

The readout housing for the SR463 Scale Systems is primarily made of aluminum. You needonly exercise caution when cleaning the display window of the electronics as this is made of clearpolyester . We recommend mild soap and water for general cleaning.

The floor transducer is covered by a Stainless Steel plate and may be vacuumed or swept.

page 5

Part No. MAN463 rev: 990324

Page 8: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

SCHEMATIC and COMPONENT LAYOUT

Part No. MAN463 rev: 990324

Page 9: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

PARTS LISTPart No. MAN463 rev: 990324

Parent Item No_ No_ Description Quantity per Position Position 2 Position 3

SE1857C4463 EPCB1857C P. C. BOARD #1857 REC. "C" 1

SE1857C4463 EC318RP .0018MFD P3182-ND DIGI-KEY 1 C4

SE1857C4463 EC510RF 0.1MFD #SR205C104KAA (AVX) 5 C11,C10, C12,C13, C14

SE1857C4463 EC747RE016 47MFD #UVX1V470MPA(NICHICON) 1 C1

SE1857C4463 EC710RE016 10MFD #UVX1C100MAA (NICHICON) 1 C2

SE1857C4463 EC810RE016 100MFD 16V CAP #UVX1C101MPA 1 C3

SE1857C4463 EC510RM050 .1MFD #R68104J63B (NISSEI) 4 C5,C8,C9, C22

SE1857C4463 EC610RM050 1MFD 168105J50G(B32529-105-63J 1 C6

SE1857C4463 EC210RP 100PF POLY CAPACITOR 1 C7

SE1857C4463 EC847RE016 470MFD RADIAL (UVX1C471M) 2 C20,C21

SE1857C4463 EC533RM .33MFD #B32529-C334J 1 C23

SE1857C4463 ED1N4001 DIODE 1N4001 (RECTRON) 1 D1

SE1857C4463 ESRBE085 SWITCH (RAYCHEM) RBE085A1 1 F1

SE1857C4463 EIICL7660C IC #ICL7660CPA (SEE TC7660CPA) 1 IC1

SE1857C4463 EIMAX135CP IC #MAX135CPI (MAXIM) 1 IC2

SE1857C4463 EICD4078BE IC #CD4078BE 1 IC4

SE1857C4463 EINMC93C46 IC #NMC93C46B (NATIONAL) 1 IC5

SE1857C4463 EIICL7652A IC #ICL7652CPA (MAXIM) 1 IC6

SE1857C4463 EITLE2426C IC #TLE2426CLP (TEXAS INSTR.) 1 IC7

SE1857C4463 ETLM340T5 TRANSISTOR (REGULATOR 5 VOLT) 1 U9A

SE1857C4463 FCBSW11404 TERMINAL STRIP #BSW-114-04-G-S 1 J5A

SE1857C4463 FCTSW11409 TERMINAL STRIP #TSW-114-09-G-S 1 J5B

SE1857C4463 ETZVNL110A TRANSISTOR,VOLTAGE REF.ZVNL110 1 Q1

SE1857C4463 ET2N3906 TRANSISTOR 2N3906 (MATOROLA) 2 Q2,Q3

SE1857C4463 EV25KKVSF8 25K POT (MOUSER) #32RM403 1 R1

SE1857C4463 ER17505W3 75 OHM 3 WATT 5% RESISTOR 1 R2

SE1857C4463 ER41005QF 10K 1/4 WATT 5% RESISTOR 9 R3,R4,R17, R22,R23, R24,R2,R29

SE1857C4463 0 R30

SE1857C4463 ER62001EF 2MEG 1% RES 1 R5

SE1857C4463 ER52491EJ 249K 1/8 WATT 1% J RESISTOR 1 R12

SE1857C4463 ER44531EJ 45.3K 1/8 WATT 1% J RESISTOR 2 R6,R8

SE1857C4463 ER43011EJ 30.1K 1/8 WATT 1% RESISTOR 1 R7

SE1857C4463 ER72205QF 22M 1/4 WATT 5% RESISTOR 1 R9

SE1857C4463 ER51501EJ 150K 1/8 WATT 1% J RESISTOR 2 R10,R11

SE1857C4463 ER54991EJ 499K 1/8 WATT 1% J RESISTOR 1 R16

SE1857C4463 ER31005QF 1K 1/4 WATT 5% RESISTOR 1 R21

SE1857C4463 ER770101 RESISTOR NETWORK 100K #770-101 4 RSIP1,2,3, RSIP4

SE1857C4463 ESP8060S SWITCH,PANASONIC #P8060S-ND 3 SW1,SW2, SW3

SE1857C4463 EXSE3331 CRYSTAL 96.000KHz (DIGI-KEY) 1 X1

SE1857C4463 EXPX200 CERAMIC RESONATOR #PX200 1 X2

SE1857C4463 EIDIP8 SOCKET 8 PIN (BURNDY) 3

SE1857C4463 EIDIP14 SOCKET,14 PIN #DILB-14P-223T 1

SE1857C4463 EIDIP28 SOCKET 28 PIN #DILB-28P-223T 1

SE1857C4463 EIDIP40 SOCKET 40 PIN #DILB-40P-223T 1

SE1857C4463 FC70543005 CONNECTOR,HEADER #705-43-0005 1

SE1857C4463 ELBRT1209 BUZZER #BRT1209-PF12 1 SP1

Page 10: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

Model SR463 Platform Installation Procedure

1. Carefully unpackage the scale platform and inspect to ensure there has been no shipping damage.2. Prepare the pit area to accept the scale platform and readout as described in fig. 1, below. 3. Mount the readout on the wall and run the connector cable down the conduit to the pit as shown below.4. Remove the platform deck by using the 1/4" hex wrench (supplied) to remove the 4 mounting screws on the cover.5. Place the platform into the pit so that the connector for the readout cable is nearest to the conduit.6. Plug the readout cable into the connector on the platform.7. Position the platform in the pit so that the frame is equally spaced from all sides of the pit.8. Using a 9/16" socket wrench, adjust the 4 corner leveler bolts so that the platform base is one inch (1") below the

surface of the floor on all sides. This will ensure that the deck is even with the floor surface when installed. NOTE: If youare planning on tiling or carpeting the deck be sure to compensate for the thickness of material. You may place the deckon the platform to check the level as you make your adjustments.

9. When your level adjustments are complete tighten the locking nuts on all 4 level bolts to lock them in place.10. Adjust the 8 side clearance adjustment bolts so that the platform is spaced equally on all sides of the pit then tighten the

locking nuts on all eight (8)bolts.11. Set the deck on to the platform and secure in place with the 4 top mounting screws.

If you have any questions please call the factory at 1(800)654-6360

Part No. MAN463 rev: 990324

8 SIDE CLEARANCEADJUSTMENT BOLTS

4 CORNERLEVEL BOLTS

Page 11: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

Part No. MAN463 rev: 990324

Page 12: Model SR463 In-Floor Platform Scale System899.1 900.0 900.9 999.0 1000.0 1001.0 page 4 Part No. MAN463 rev: 990324 HOLD / RECALL MODE DISPLAY ZERO 0 WEIGH 0.0 W Lb Kg HIDDEN BUTTONS

Part No. MAN463 rev: 990324