model tc-34 - home - acd · model tc-34.2 • active thrust balancing system for extended bearing...

2
MODEL TC-34.2 Active thrust balancing system for extended bearing life High efficiency hydraulics with extremely low NPSHR inducer Light weight and compact Available in sump and in-tank designs Special design VFD drive provides operation point control over the entire pump operating range Features a quick electrical disconnect for ease of maintenance Permanent magnet motor All parts from wrought aluminum precision machined Vacuum jacketed sump Heavy duty ceramic bearings Fuel supply systems for rail locomotives Low pressure marine fuel systems HP Booster pump Liquid storage transfer Bunkering operations Peak-shaving Trailer off-loading Liquid Nitrogen Liquid Argon Ethylene Ethane Methane (LNG) Propane Differential pressure gauge Loss of prime detector (cavitation protection) Safety relief valve Dual conduit box per NFPA standards for LNG services Complete removal systems Long term storage container High-efficiency submerged pump Vacuum jacketed sump Custom made VFD drive – factory string tested Dual electrical feed thru hermetically sealed up to 500A FEATURES & BENEFITS APPLICATIONS LIQUIDS PUMPED OPTIONAL ACCESSORIES COMPLETE PUMPING SYSTEM * Consult ACD engineering for actual ratings. SPECIFICATIONS* Flow Range gpm 1 – 1,600 lpm 4 – 6,056 NPSHR feet 0.5 – 5 meters 0.15 – 1.5 Differential Head feet 50 – 4,000 meters 15 – 1,220 Pump Design Rating hp 3.35 – 335 kw 2.5 – 250 RPM Range* rpm 2,000 – 10,000 STATE-OF-THE-ART SUBMERGED MOTOR PUMPS Suction Pot Mounted Installation In-tank and Removable Installations

Upload: vuonghuong

Post on 16-Feb-2019

293 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Model TC-34 - Home - ACD · Model TC-34.2 • Active thrust balancing system for extended bearing life • High efficiency hydraulics with extremely low NPSHR inducer • Light weight

Model TC-34.2

• Active thrust balancing system for extended bearing life

•HighefficiencyhydraulicswithextremelylowNPSHRinducer

•Lightweightandcompact•Availableinsumpandin-tankdesigns•SpecialdesignVFDdriveprovidesoperationpointcontrolovertheentirepumpoperatingrange

•Featuresaquickelectricaldisconnectforease of maintenance

•Permanentmagnetmotor•Allpartsfromwroughtaluminumprecisionmachined

•Vacuumjacketedsump• Heavy duty ceramic bearings

•Fuelsupplysystemsforraillocomotives•Lowpressuremarinefuelsystems•HPBoosterpump•Liquidstoragetransfer •Bunkeringoperations•Peak-shaving•Traileroff-loading

•LiquidNitrogen•LiquidArgon• Ethylene • Ethane•Methane(LNG)•Propane

•Differentialpressuregauge•Lossofprimedetector(cavitationprotection)

•Safetyreliefvalve•DualconduitboxperNFPAstandardsforLNGservices

•Completeremovalsystems• Long term storage container

•High-efficiencysubmergedpump•Vacuumjacketedsump•CustommadeVFDdrive–factory

string tested•Dualelectricalfeedthruhermeticallysealedupto500A

Features & BeneFits applications

liquids pumped

optional accessories

complete pumpinG sYstem

* ConsultACDengineeringforactualratings.

speciFications*

Flow Rangegpm 1 – 1,600

lpm 4 – 6,056

NPSHRfeet 0.5 – 5

meters 0.15 – 1.5

Differential Head

feet 50 – 4,000

meters 15 – 1,220

Pump Design Rating

hp 3.35 – 335

kw 2.5 – 250

RPM Range* rpm 2,000 – 10,000

STATE-OF-THE-ART SUBMERGED MOTOR PUMPS

Suction Pot Mounted Installation

In-tank and Removable Installations

Page 2: Model TC-34 - Home - ACD · Model TC-34.2 • Active thrust balancing system for extended bearing life • High efficiency hydraulics with extremely low NPSHR inducer • Light weight

Manufacturing

2321 S. Pullman Street Santa Ana, CA 92705 USATel 800.525.4216 (USA only)Tel +1.949.261.7533 • Fax [email protected] • www.acdcom.com

global service

north americaatlantaAtlanta, Georgia, USA+1 404.696.8113 • Fax +1 [email protected] • cryoindservice.com

california (acd service) Santa Ana, California, USA+1.714.568.0201 • Fax [email protected] • acdcom.com

houstonHouston, Texas, USA+1 281.590.4800 • Fax +1 [email protected] • cryoindservice.com

pittsburghImperial, Pennsylvania, USA+1 724.695.1910 • Fax +1 [email protected] • cryoindservice.com

red deerRed Deer, Alberta, Canada+1.403.352.4436 • Fax [email protected] • cryoindservice.com

torontoToronto, Ontario, Canada+1 416.502.1950 • Fax +1 [email protected] • cryoindservice.com

international

australiaDandenong, Victoria, Australia+61.3.9791.7888 • Fax [email protected] • cryoquip.com

chinaHangzhou, China+86.571.8619.4799 • Fax [email protected] • cryoindservice.com

europe (acd crYo)CH-4142 Muenchenstein Switzerland+41.61.413.0230 • Fax: [email protected] • acdcryo.com

D-79415 Bad Bellingen Germany+49.7635.8105.0 • Fax: [email protected] • acdcryo.com

united arab emiratesJebel Ali Free Zone, Dubai, UAETel: [email protected] • acdcom.com

indiaA Division of Rhine Engineering Pvt. Ltd.Vadodara, Gujarat, India+91.265.283 0113 • Fax +91.265.283 [email protected] • acdcom.comKolkatta, West Bengal, India+91.973.216 [email protected] • acdcom.com

KoreaYongin-si, Gyeonggi-do, Korea+82.31.286.6114 • Fax [email protected] • cryoindservice.com

malaysiaShah Alam, Selangor D.Ehsan, Malaysia+60 (3) 5740.4800 • Fax +60 (3) [email protected] • cryoindservice.com

Bulletin No. ACD TC 34.2 – 2016© 2016 ACD LLC, Printed in USASPECIFICATIonS SUbJECT To CHAngE wITHoUT noTICE

Model TC-34.2

tYpical installation schemes

pump perFormance map

10

100

1000

1 10 100 1000

Diff

eren

tial H

ead

– fe

et

3.0

30.5

304.8

Diff

eren

tial H

ead

– m

eter

s

Flow Rate – gpm

H210

G210

H170

G170

G145F145

D145

E145

D125

C125

D90

C90

3.8 38 379 3785

Flow Rate – lpm

Suction Pot Mounted in Vacuum Jacketed Vessel

In-tank Fixed Optional Removal System