■ 2-pipe R407C heat pump VRF system

■ From 8 to 46 HP in one piping system

(19 steps)

■ Active leak detection system option

■ Up to 40 indoor units

■ Up to 30m vertical lift between indoor units

■ Ultra compact

■ Quiet

■ A unique control offer

Outdoor Units

Indoor Units

Ceiling

Console

consistent leaders through constant

Residential ApplicationsIntelligent Energy Saving outdoor unit

Commercial ApplicationsSuper Multi outdoor unit3-pipe VRF

Commercial ApplicationsModular Multi outdoor unit2-pipe VRF

innovation

A consistent leader in electronics, Toshiba is committed to delivering the higheststandards of quality and innovation in all of the industries in which the company is amajor player.

These principles are clearly demonstrated in its air conditioning division, whereToshiba continues to develop market leading products for both commercial andresidential customers.

1875 Toshiba established as a pioneer of Japan’s technology industry.

1957 Toshiba enters the air conditioning business.

1969 Toshiba introduces the first portable units.

1977 Toshiba is first to introduce electronic control for air conditioning units.

1981 The first inverter technology is launched by Toshiba.

1988 Toshiba is first to introduce the twin rotary compressor.

1999 Toshiba is the first air conditioning manufacturer to launch a full range of unitspurpose-designed for use with non-ozone depleting refrigerants.

2000 The most advanced inverter-driven residential units are introduced. Electricityconsumption by air conditioning units is now at its lowest, with COP betweenthree and more than five.

2001 A new generation 2-pipe VRF system is launched: the Modular Multi.It is not only outclassing all other VRF systems in terms of performance, it isthe only VRF system that is designed specifically for R407C. Additionally it canintegrate an active leak-detection system.

Toshiba is committed to designing and manufacturing products in the mostenvironmentally friendly way possible. Toshiba will not be satisfied until itscommitment and record on protecting the natural environment are unmatched.

State of the art inverter drive technology

the environment and energy efficien

Meeting today’s environmental demands.And tomorrow’s

■ R407C only■ Highly energy-efficient system■ Compact design to reduce waste■ Minimisation of electromagnetic harmonics■ Intelligent leak detection system optional

ncy

HFCs (e.g. R22) are being phased out to prevent ozone depletion and inducedGlobal Warming.

To ensure serviceability of installed equipment and in line with present and futurerestrictions, Toshiba offers only R407 VRF systems – providing long-termdedication to customers.

Raising your safety standardsThe newly enforced EN378 lays down maximum exposure limits for leakage.Emphasis is being given to protect permanently manned rooms. Non-compliance implies legal and financial liability for businesses. Toshiba pioneersagain by developing leak detection accessories integrated within the controlsystem, hence respecting both staff and businesses. This option consists of roomsensors – positioned in permanently manned rooms – connected to a simplePCB to be placed on the inverter outdoor unit.

2-stage control1– Non-toxic leak = Fault code generated –

System still operates2– Potentially toxic leak = System stops –

Manual reset required

EN378

Energy efficiency: the greatest adaptability to load changes Keeping running cost at the lowest:■ Proportional control starts as low as at 10% of nominal load■ Up to 135% diversity■ Precise temperature control at 0.5˚K■ More efficient newly developed 4-sided heat exchanger and blower room

Minimisation of electromagnetic harmonics■ DC reactor reduced harmonics■ 2-in-1 compressor pack of each module reduces harmonics by 50% on a 10 HP,

up to 88% in a 46 HP system

The most compact and quiet VRF system ever■ Volume, weight and number of components reduced by more than 25%

= Reducing waste■ The most compact 10 HP on the market■ New development reduces operating noise to 58dBa on a 10 HP unit

InverterConstant Speed

Operation (HP)

Demand(HP)

10 HPInverter

10 HPFixed

10 HPFixed

Inv. Fix.5HP 5HP

Fix. Fix.5HP 5HP

Fix. Fix.5HP 5HP

a new technology-packed system

Unchallenged performances through cutting-edge technology and state-of-the-art design

■ Up to 40 indoor units, up to 46 HP■ 30m lift between indoor units■ More capacity and more precise control■ Total design flexibility

– Smallest installation area– Infinite piping possibilities

Intelligent Power Drive Unit (IPDU)The latest Inverter technology enables:■ Combination of up to 5 outdoor units (46 HP)

without any function unit■ Always the most precise proportional control

(from 10%)■ Integration of pressure and heat sensors in the

indoor units■ The most intelligent oil balancing control

A-1 – Advanced oil separator in each outdoor unit to prevent the rapid fallof oil level at system start

A-2 – Regular return to compressorA-3 – Oil-level balancing between outdoor unitsB – Compressor pack maintains required oil levelC – Intelligent oil retrieval system (once per hour minimum and during

low load operation as well)= Achieves the industry ’s smallest installation area= Up to 40 indoor units – from 8 to 46 HP in one piping circuit= Up to 30m lift versus 15m for old generation VRF systems= Precise capacity control along the pipe run= No restriction on piping design (header after header…)

A fully redesigned outdoor unit

Pressure and heat sensor control in each indoor unit

Intelligent sensors combined with the intelligent inverter control eliminatescapacity differences between indoor units.

With this technology an indoor unit will always operate at optimum capacitywhatever its position on the piping circuit, thus simplifying design. This also allowsusing a line branching or even a header branching after a header branching.

■ A newly developed stealth fan enables greater airflow with lower noise

■ A new bell mouth gives efficient air discharge with lower noise

■ Separation between compressor chamber and air discharge to place a more efficient 4-sided heat exchanger

■ The compressor is located on a sliding tray to assist servicing

= Improves heat exchange ratio (COP)= Improves noise level = Improves serviceability with an immediate access to major components

modular multi benefits

■ Designed for R407C■ The best performances across all criteria■ Easy to install and design

■ Precision: capable of maintaining temperature to within 0.5˚C, even with quick load changes

■ Lower running costs:– 10% to 100% variable compressor capacity– Up to 135% diversity– 50 to 100% capacity control for each

indoor unit■ No plant room or frost protection required■ The smallest installation area from 8 HP to 46 HP■ The quietest VRF system on the market■ Safety: intelligent leak detection system available■ Flexibility to adapt with no or minimum

disruption, during or after installation:– the number or the type of indoor units

(connectable capacity ranges between 50and 135%)

Performance■ A large range to suit every application:

– Indoor units– 19 VRF systems from 8 HP to 46 HP

■ Up to 40 indoor units in one piping circuit■ Up to 135% diversity■ Up to 100 (125)m actual (equivalent) length ■ Up to 30m vertical lift between indoor units:

– Greater flexibility in the location of the system– Up to 8 floors in one piping

■ No plant room or frost protection required■ Intelligent oil-balancing control■ Intelligent leak detection system■ The quietest VRF system on the market■ The smallest installation area from 8 HP

to 46 HP■ Up to 50m piping length from first branch

to the furthest indoor unit

Simplified, flexible design■ Total design flexibility: no restrictions on

piping design (line or header branching afterheader branching)

■ Allows phased installation due to design flexibility

■ Simplified design:– Constant capacity for indoor units whatever

their position along the piping circuit– Up to 30m lift between indoors– Up to 20m length and 4m lift between outdoor

unit modules– All outdoor modules have same dimensions

Specification benefits

End user benefits

■ Compact design: can be transported in a normal elevator

■ Immediate access to all major components:– Compressor mounted on a sliding tray– Separates machine room and blower room

■ Advanced bus communication system for control:– Non-polarised simple 2-wire system– Automatic configuration and self diagnostics system

■ Electronic fault diagnosis system (1 in outdoor, 1 in indoor)

■ Dyna Doctor III Service and maintenance software kit: provides step by step troubleshooting process

Ease of installation and maintenance

keeping control

■ Standard and centralised controllers■ Analogue BMS integration possible■ LONWORKS® integration possible

®LONWORKS is a registered mark of Echelon Corporation

Simplified RBC-SR2-PE RBC-IR2-PE

BMS analogue interfaceRBC-BG1-PE

■ Simplified remote controllers: easy to use, wired (shown left) or wireless (shown right)

■ Standard controllerswired or wireless

■ Weekly timer option

■ Central remote controllers:– 16 masters x 16 slaves: up to 256 units (left)– 64 masters x 16 slaves: up to 1024 units (right)

With zoning features

■ BMS interface– BMS analogue interface (left) – LONWORKS interface (right):

■ Connects to the latest and most powerful control network

■ Enables integration with all LONWORKS

compliant systems

RBC-WT1-PE

LONWORKS interface RBC-LG1-PE

RBC-1R1-PE

RBC-CR1-PE RBC-CR64-PE

All individual remote controllers offer a group controlfunction of up to 16 indoor units.

RBC-SR1-PE

superior control

■ Interactive intelligence management software:– Total system supervision and control– Internet access– Energy monitoring

■ Unique service and maintenance tool:Dyna Doctor III software

Standard safety devices are high and low pressure switches, compressor safety switchesand pressure sensor control. As usual, electronic fault diagnosis system is standard on all indoor/outdoor units.

Modularity (up to 46 HP with 5 outdoor units combined) has led Toshiba to developspecific functions to ensure minimum disruption for the end user in the worse casescenarios:

– Inverter failure – DOL (fixed-speed) back-up operation possible– Outdoor module failure – individual replacement possible

Expect the unexpected – safety devices

This kit enables information retrieval directly from:– Outdoor units– Indoor units

Combined with the fault diagnosis system it provides the servicing engineer with a user-friendly step by step process to fix potential installation problems or system malfunctions

The mostpowerful serviceandmaintenance kit:Dyna Doctor III

FeaturesThis package is a user-friendly PC-compatible management softwarerunning under Windows® (registeredmark of Microsoft Corporation)

It controls up to 64 interfaces – eachcontrolling a group up to 16 indoor–units - totalling up to 1024 units

■ Total supervision■ Automatic configuration with

name/location of indoor units■ Start optimisation

based on experience■ Data logging■ Alarm logging■ Internet access (option)■ Energy monitoring (option)

up to 64 units}Interactive intelligence

system dataExample of 40 HP system with 40 indoor units

Branching Kits

Nature Model namekW HP

Indoor unit capacity handled (1*) Appearance

RBM-Y018RBM-Y037RBM-Y071RBM-Y129

RBM-H4037RBM-H4071RBM-H8037RBM-H8071

RBM-T129

< 18kW18kW < Capacity < 37kW37kW < Capacity < 71kW

71kW < Capacity18kW < Capacity < 37kW37kW < Capacity < 71kW18kW < Capacity < 37kW37kW < Capacity < 71kW

1 set of 3 types to be combined on site

< 6.46.4 < Capacity < 13.2

13.2 < Capacity < 25.225.2 < Capacity

6.4 < Capacity < 13.213.2 < Capacity < 25.26.4 < Capacity < 13.2

13.2 < Capacity < 25.2

Y-shape branching joint

4-branching header (2*)

8-branching header (2*)

T-shape branching joint(for outdoor units)

Connection pipe–Balance pipe–Piping at liquid side–Piping at gas side

Diameter in mm (inches)9.52 (3/8)

12.7 (1/2) to 22.2 (7/8)22.2 (7/8) to 54.1 (21/8)

(1*) : If total indoor unit capacity exceeds total outdoor unit capacity, use total outdoor capacity(2*) : If line branching after header branching, maximum 16.8kW (6 HP) can be connected

Specifications are subject to change without notice

Selection of the indoor units required for system operation

(*): Also available with infrared control

Model capacityCooling capacityCooling capacityHeating capacity

Power Source

2-Way Cassette4-Way Cassette (*)Slim Duct and DuctWall (*)Ceiling (*)Console (*)Chassis

1 Phase – 220-240V – 50Hz(power exclusive for indoor is required)

HPkWkW

028 042 056 080 112 1401 1.5 2 3 4 5

2.8 4.2 5.6 8 11.2 143.2 4.8 6.4 9.6 12.8 15.8

MM-TU028 MM-TU042 MM-TU056MM-U056 MM-U080 MM-U112 MM-U140

MM-SB028 MM-B056 MM-B080 MM-B112 MM-B140MM-K042 MM-K056 MM-K080MM-C042 MM-C056 MM-C080 MM-C112 MM-C140

MM-S056 MM-S080MM-N028 MM-N042 MM-N056 MM-N080

Overview of the 19 Modular Multi systems

(*): Assumption 135% diversity: depends on configuration

8HP 4-10.8 MM-A-022.4HT 22.4 25 1 8HP 1310HP 5-13.5 MM-A-028HT 28 31.5 1 10HP 1614HP 7-18.9 MM-A-038.4HT 38.4 43 2 8HP 6HP 1616HP 8-21.6 MM-A-044.8HT 44.8 50 2 8HP 8HP 1818HP 9-24.3 MM-A-050.4HT 50.4 56.5 2 10HP 8HP 1820HP 10-27 MM-A-056HT 56 63 2 10HP 10HP 2022HP 11-29.7 MM-A-060.8HT 60.8 68 3 8HP 8HP 6HP 2224HP 12-32.4 MM-A-067.2HT 67.2 75 3 8HP 8HP 8HP 2426HP 13-35.1 MM-A-072.8HT 72.8 81.5 3 10HP 8HP 8HP 2628HP 14-37.8 MM-A-078.4HT 78.4 88 3 10HP 10HP 8HP 2830HP 15-40.5 MM-A-084HT 84 94.5 3 10HP 10HP 10HP 3032HP 16-43.2 MM-A-089.6HT 89.6 100 4 8HP 8HP 8HP 8HP 3234HP 17-45.9 MM-A-095.2HT 95.2 106.5 4 10HP 8HP 8HP 8HP 3436HP 18-48.6 MM-A-0100.8HT 100.8 113 4 10HP 10HP 8HP 8HP 3638HP 19-51.3 MM-A-0106.4HT 106.4 119.5 4 10HP 10HP 10HP 8HP 3840HP 20-54 MM-A-0112HT 112 126 4 10HP 10HP 10HP 10HP 4042HP 21-56.7 MM-A-0117.6HT 117.6 131.5 5 10HP 8HP 8HP 8HP 8HP 4044HP 22-59.4 MM-A-0123.2HT 123.2 138 5 10HP 10HP 8HP 8HP 8HP 4046HP 23-62.1 MM-A-0128.8HT 128.8 144.5 5 10HP 10HP 10HP 8HP 8HP 40

Capacity in HP

System Connectable (*)

SystemCapacity in kW

Cooling Heating

No. ofmodules

Outdoor modules

Inverter Constant-speed

Maximum number of

indoor units

MM-A0224HT MM-A0280HT MM-A0160HX MM-A0224HX MM-A0280HX8 10 6 8 10

22.4 28 16 22.4 2825 31.5 18 25 31.5

260 270 190 255 26558 58 58 58 58

Overview of the 5 outdoor modules

Model NameInverter Units

1010 x 1550

-5 to 43-15 to 21

Constant-speed units

HPkWkW

mm

mm

mmKgs

dB(a)˚C˚C

1700 x 990 x 75020x800

(500mm at the front, 300mm the rear, 10mm on each side)

System capacityCooling capacityHeating capacity

DimensionsUnit (HxWxD)

Service area (WxD)

Total installation area (WxD)WeightNoise level

CoolingHeating

Operation range

2 Way Cassette (TU type)• Only 190mm high: the

slimmest on the market• High-efficiency drain pump• Quiet operation• Easy access for maintenance

4 Way Cassette (U type)• Slim• High-efficiency drain pump• Ultra quiet up to 14.0 kW• Easy access to components• Fresh air intake

Slim Duct (SB type)• Only 220mm high• Ultra quiet• Rear or lower air return• Filter included as standard

Duct (B type)Standard features:• 2, 3 or 4 outlets• Full thermal and electrical

insulation• Insulation against noise• Electrical kit for external pressure up to 100Pa• Lower air return or rear option

modular multi indoor units

Wall Mounted Units (K type)• Quick and easy to install• Motorised louvres• Quiet operation

Ceiling (C type)• Quick and easy to install• Partial concealment possible• Fresh air intake• Elegant design

Console (S type)• Minimum footprint• Partial concealment possible• Fresh air intake• Elegant design

Chassis (N type)• Top or front air outlet possible• Ideal for renovation and

concealment

E10402

MMB1100E