  • Technical Data Leafl etTS0015UK03

    RS/M SeriesModulating Gas Burners

    The RS/M burners series covers a fi ring range from 70 to 2650 kW, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.Operation can be two stage progressive or, alternatively, modulating with the installation of a PID logic regulator and respective probes.RS/M burners series guarantees high effi ciency levels in all the various applications, thus reducing fuel consumption and running costs.The exclusive design ensures reduced dimensions, simple use and maintenance.A wide range of accessories guarantees elevated working fl exibility.

    Gas

    RS 34/M MZ 70/130 390 kWRS 44/M MZ 101/203 550 kWRS 50/M 85/290 580 kWRS 64/M MZ 150/400 850 kWRS 70/M 135/465 814 kWRS 100/M 150/698 1163 kWRS 130/M 160/930 1512 kWRS 190/M 470/1279 2290 kWRS 250/M MZ 600/1250 2650 kW

  • 2

    RS/M Series

    Technical Data

    Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features, the technical data, the equipment and the accessories can be changed. This document contains confi dential and proprietary information of RIELLO S.p.A. Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.

    Reference conditions:Temperature: 20C - Pressure: 1013,5 mbar - Altitude: 0 m a.s.l. - Noise measured at a distance of 1 meter.

    MODEL RS 34/M MZ RS 44/M MZ RS 50/M RS 64/M MZBurner operation mode Modulating (with regulator and probes accessories)Modulation ratio at max. output 6 1

    Servomotortype SQN90run time s 24

    Heat outputkW 70/130390 101/203550 85/290580 150/400850Mcal/h 60/112335 87/175473 73/249499 129/344731

    Working temperature C min./max. 0/40 FUEL/AIR DATANet calorifi c value G20 gas kWh/Nm3 10Density gas G20 kg/Nm3 0,71Output gas G20 Nm3/h 7/1339 10/2055 8,5/2958 15/4085Net calorifi c value G25 gas kWh/Nm3 8,6Density gas G25 kg/Nm3 0,78Output gas G25 Nm3/h 8/1545 12/2464 10/3468 17/4799Net calorifi c value LPG gas kWh/Nm3 25,8Density LPG gas kg/Nm3 2,02Output LPG gas Nm3/h 3/515 4/821 4/1123 6/1633Fan Type (02) (02) (01) (02)Air temperature Max. C 60 ELECTRICAL DATAElectrical supply Ph/Hz/V (04) (04) (06) (05) (05)Auxiliary electrical supply Ph/Hz/V (04) (04) (03) (03)Control box Type RMG/M RMG/M LFL 1.333 RMG/MTotal electrical power kW 0,6 0,7 0,75 0,75 1,4Auxiliary electrical power kW 0,3 0,28 0,3 0,12 0,3Protection level IP 40 40 44 40Motor electrical power kW 0,3 0,42 0,45 0,65 1,1Rated motor current A 3,2 3,5 2 - 1,4 3 - 1,7 4,8 - 2,8 Motor start current A 15 17 14 - 10 13,8 - 8 25 -14,6Motor protection level IP 54

    Ignition transformerV1 - V2 230V-1x15 kV 230V-1x15 kV 230V-1x8 kV 230V-1x15 kVI1 - I2 1A - 25 mA 1A - 25 mA 1A - 20 mA 1A - 25 mA

    Operation Intermittent (at least one stop every 24 h) - Continuous as optional (at least one stop every 72 h) EMISSIONSSound pressure dBA 70 72 72 76Sound output W --CO Emission mg/kWh < 40NOx Emission mg/kWh < 120 < 120 < 130 < 120 APPROVALDirective 90/396 - 89/336 (2004/108) - 73/23 (2006/95) - 92/42 ECConforming to EN 676Certifi cation CE 0085BR0378 CE 0085BR0378 CE 0085AQ0709 in progress

    (01) Centrifugal with reverse curve blades(02) Centrifugal with forward curve blades(03) 1/50/230~(10%)(04) 1/50-60/220-230~(10%)(05) 3/50/230-400~(10%)(06) 3/50-60/220-400~(10%)(07) 3/50/400~(10%) (08) 3/50/230~(10%)

  • 3

    Reference conditions:Temperature: 20C - Pressure: 1013,5 mbar - Altitude: 0 m a.s.l. - Noise measured at a distance of 1 meter.

    MODEL RS 70/M RS 100/M RS 130/M RS 190/M RS 250/M MZBurner operation mode Modulating (with regulator and probes accessories)Modulation ratio at max. output 6 1

    Servomotortype SQN31run time s 42

    Heat outputkW 135/465814 150/6981163 160/9301512 470/12792290 600/12502650Mcal/h 116/400700 129/6001000 138/8001300 405/11001970 516/10752279

    Working temperature C min./max. 0/40 FUEL/AIR DATANet calorifi c value G20 gas kWh/Nm3 10Density gas G20 kg/Nm3 0,71Output gas G20 Nm3/h 13,5/46,581,4 15/70116 16/93151 47/128229 60/125265Net calorifi c value G25 gas kWh/Nm3 8,6Density gas G25 kg/Nm3 0,78Output gas G25 Nm3/h 16/5495 17/81135 19/108176 55/149266 70/145308Net calorifi c value LPG gas kWh/Nm3 25,8Density LPG gas kg/Nm3 2,02Output LPG gas Nm3/h 5/1832 6/2745 6/3659 18/5089 23/48103Fan Type (01) (01) (01) (02) (02)Air temperature Max. C 60 ELECTRICAL DATAElectrical supply Ph/Hz/V (05) (05) (05) (05) (07) (08)Auxiliary electrical supply Ph/Hz/V (03) (03) (03) (03) (03)Control box Type LFL 1.333 LFL 1.333 LFL 1.333 LFL 1.333 RMG/MTotal electrical power kW 1,4 1,8 2,6 5,5 6,5Auxiliary electrical power kW 0,3 0,3 0,4 1 1Protection level IP 44 44 44 44 44Motor electrical power kW 1,1 1,5 2,2 4,5 5,5Rated motor current A 4,8 - 2,8 5,9 - 3,4 8,8 - 5,1 15,8 - 9,1 12,3 21,3 Motor start current A 25 - 14,6 27,7 - 16 57,2 - 33,2 126 - 73 83 143Motor protection level IP 54

    Ignition transformerV1 - V2 230V-1x8 kV 230V-1x8 kV 230V-1x8 kV 230V-1x8 kV 230V-1x15 kVI1 - I2 1A - 20 mA 1A - 20 mA 1A - 20 mA 1A - 20 mA 1A - 20 mA

    Operation Intermittent (at least one stop every 24 h) - Continuous as optional (at least one stop every 72 h) EMISSIONSSound pressure dBA 75 77 78,5 81 83Sound output W --CO Emission mg/kWh < 40NOx Emission mg/kWh < 130 < 130 < 130 < 130 < 120 APPROVALDirective 90/396 - 89/336 (2004/108) - 73/23 (2006/95) - 92/42 ECConforming to EN 676Certifi cation CE 0085AQ0708 CE 0085AQ0708 CE 0085AQ0708 CE 0085AT0042 CE 0085BS01140

    (01) Centrifugal with reverse curve blades(02) Centrifugal with forward curve blades(03) 1/50/230~(10%)(04) 1/50-60/220-230~(10%)(05) 3/50/230-400~(10%)(06) 3/50-60/220-400~(10%)(07) 3/50/400~(10%) (08) 3/50/230~(10%)

  • 4

    RS/M Series

    FIRING RATES

    Useful working fi eld for choosing the burner

    Modulation range

    Test conditions conforming to EN 676:Temperature: 20CPressure: 1013,5 mbarAltitude: 0 m a.s.l.

  • 5

    GAS TRAINS

    Fuel Supply

    The burners are fitted with a butterfly valve to regulate the fuel, controlled by a variable profi le cam servomotor.Fuel can be supplied either from the right or left hand sides. A maximum gas pressure switch stops the burner in case of excess pressure in the fuel line (as accessory on RS 34-44/M MZ).The gas train can be selected to best fi t system requirements depending on the fuel output and pressure in the supply line.The gas train can be Multibloc type (containing the main components in a single unit) or Composed type (assembly of the single components).

    Example o f the var iab le pro f i le cam on RS 34-44/M MZ burners.

    Example of the variable profi le cam on RS 250/M MZ burners.

    1 Gas input pipework2 Manual valve3 Anti-vibration joint4 Pressure gauge with pushbutton cock5 Filter6 Pressure regulator (vertical)7 Minimum gas pressure switch8 VS safety solenoid (vertical)

    9VR regulation solenoid (vertical) Two settings: - fi ring output (rapid opening) - maximum output (slow opening)

    10 Gasket and fl ange supplied with the burner11 Gas adjustment butterfl y valve12 Burner

    13

    Seal control mechanism for valves 8-9. According to standard EN 676, the seal control is compulsory for burners with maximum output above 1200 kW (in gas train with seal control)

    14 Gas train-burner adapter15 Maximum gas pressure switchP1 Combustion head pressureP2 Pressure downstream from the regulatorP3 Pressure upstream from the fi lter

    LGas train supplied separately, with the code given in the table

    L1 Installers responsibility

    L L1

    12

    P1

    11

    1015

    14 9 8 P2 6 P3

    4

    3 2 15

    7

    13

    MULTIBLOC gas train type MBD

    MULTIBLOC gas train type MBC 1200

    12

    P1

    15 1110

    14 6

    L L1

    9 13 8

    7

    5

    4

    P3P23 2 1

    COMPOSED gas train

    L L1

    12

    P1

    1511

    10

    14 9 13 6 8

    7

    5

    4

    P3P23 2 1

  • 6

    RS/M Series

    Gas trains are approved by standard EN 676 together with the burner.

    The overall dimensions of the gas train depends on how they are constructed. The following table shows the maximum dimensions of the gas trains that can be fi tted to RS/M burners, intake and outlet diameters and seal control if fi tted.Please note that the seal control can be installed as an accessory, if not already installed on the gas train.The maximum gas pressure of gas train Multibloc type is 360 mbar, and that one of gas train Composed type is 500 mbar.The range of pressure in the MULTIBLOC with fl ange can be modifi ed choosing the stabiliser spring (see gas train accessory).

    Example of gas train MULTIBLOC type MBD Example of gas train MULTIBLOC type MBC 1200

    NAME CODE I O X mm Y mm Z mm OUTPUT PRESSURE RANGE

    (mbar)

    SEAL CONTROL

    MU

    LTIB

    LOC

    GA

    S T

    RA

    INS

    MBD 4053970500 (1)3970553 (1)

    3/4 3/4 371 186 120 4 - 20 Accessory

    MBD 4073970229 (2)

    3970599 (1)(3)3970554 (1)

    3/4 3/4 371 196 120 4 - 20 Accessory

    MBD 4103970230 (2)

    3970600 (1)(3)3970144 (1)

    1 3/4 405 217 145 4 - 20 Accessory

    MBD 4123970231 (2)

    In progress (1)(3)11/4 11/4 433 217 145 4 - 20 Accessory

    MBD 412 CT3970197 (1)3970180 (1)

    11/4 11/4 433 217 262 4 - 20 Incorporated

    MBD 4153970232 (2)

    3970250 (1)(3)11/2 11/2 523 250 100 4 - 33 Accessory

    MBD 415 CT3970198 (1)

    3970253 (1)(3)11/2 11/2 523 250 4 - 33 Incorporated

    MBD 4203970181 (1)3970233 (2)3970182 (1)

    2 2 523 300 4 - 33 Accessory

    MBD 420 CT3970234 (2)

    3970252 (1)(3)2 2 523 300 227 4 - 33 Incorpo