CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
12-21January 2001
Molded Case Circuit Breakers
12
10 – 225 AmperesF-Frame
Vol. 1, Ref. No. [0487]
Product SelectionTable 12-33. Types ED, EDH, and EDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed
Note: Instruction Leaflet/FRED Number 29C101
Table 12-34. Type EHD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
1 Not UL listed. 5 kAIC interrupting rating.2 UL listed for SWD applications, see NEC Article 240-83 (d).
Note: Instruction Leaflet/FRED Number 29C101
MaximumContinuousAmpereRating@ 40°C
240V AC Maximum, 125V DC (Includes Terminals on Load End Only)
65 kAIC @ 240V AC 100 kAIC @ 240V AC 200 kAIC @ 240V AC
Type ED Type EDH Type EDC Current Limiting
2-Pole 3-Pole 2-Pole 3-Pole 2-Pole 3-Pole
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
100125150175200225
ED2100ED2125ED2150ED2175ED2200ED2225
357.357.357.357.357.357.
ED3100ED3125ED3150ED3175ED3200ED3225
885.885.885.885.885.885.
EDH2100EDH2125EDH2150EDH2175EDH2200EDH2225
850.850.850.850.850.850.
EDH3100EDH3125EDH3150EDH3175EDH3200EDH3225
1,280.1,280.1,280.1,280.1,280.1,280.
EDC2100EDC2125EDC2150EDC2175EDC2200EDC2225
1,200.1,200.1,200.1,200.1,200.1,200.
EDC3100EDC3125EDC3150EDC3175EDC3200EDC3225
1,655.1,655.1,655.1,655.1,655.1,655.
MaximumContinuousAmpere Rating@ 40°C
277V AC Maximum, 125V DC 480V AC Maximum, 250V DC
14 kAIC @ 277V AC 14 kAIC @ 480V AC
Type EHD (Includes Terminals on Load End Only)
1-Pole 2-Pole 3-Pole
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
10 1 15 20 25 30 35 40 45 50 60 70 80 90100
EHD1010EHD1015 2
EHD1020 2
EHD1025EHD1030EHD1035EHD1040EHD1045EHD1050EHD1060EHD1070EHD1080EHD1090EHD1100
123.123.123.123.123.123.123.123.123.123.238.239.238.238.
EHD2010EHD2015EHD2020EHD2025EHD2030EHD2035EHD2040EHD2045EHD2050EHD2060EHD2070EHD2080EHD2090EHD2100
387.387.387.387.387.387.387.387.387.387.505.505.505.505.
EHD3010EHD3015EHD3020EHD3025EHD3030EHD3035EHD3040EHD3045EHD3050EHD3060EHD3070EHD3080EHD3090EHD3100
498.498.498.498.498.498.498.498.498.498.600.600.600.600.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
TAB1201.fm Page 21 Wednesday, October 25, 2000 9:37 PM
12-20
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
Molded Case Circuit Breakers
12
10 – 225 AmperesF-Frame
Vol. 1, Ref. No. [0486]
Dimensions/WeightsTable 12-30. Dimensions in Inches (mm) Table 12-31. Approximate Shipping Weight, Lbs. (Kg)
Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbers for circuit breakers or trip units.
Table 12-32. Circuit Breaker Catalog Numbering System
Number of Poles
Width Height Depth
12
1.375 (35)2.75 (70)
6 (152)6 (152)
3.375 (86)3.375 (86)
34
4.125 (105)5.5 (140)
6 (152)6 (152)
3.375 (86)3.375 (86)
Breaker Type Number of Poles
1 2 3 4
ED, EDH, EDC — 3 (1.361) 4.5 (2.041) —
EHD, FDB, FD, HFD, FDC 2 (.907) 3 (1.361) 4.5 (2.041) 6 (2.721)
Circuit Breaker Type
EHDFDBFDHFDFDC
Number of Poles
1 = 1 Pole2 = 2 Poles3 = 3 Poles4 = 4 Poles
Trip Amperes
010015020025030035040045050060070080090100110125150175 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)200 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)225 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)
Suffix
E = 100% Protected (4-Pole only) Neutral PoleEH = 50% Protected (4-Pole only)K = High Magnetic Molded Case SwitchL = Line and Load TerminalsS = Stainless Steel TerminalsV = 50°C CalibrationW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (≤ 100 Amperes)
F D C 3 1 0 0 L
E D C 3 2 0 0 L
Circuit Breaker Type
EDEDHEDC
Number of Poles
2 = 2-Pole3 = 3-Pole
Trip Amperes
100125150175200225
Suffix
L = Line and Load TerminalsW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (100 Amperes)
TAB1201.fm Page 20 Wednesday, October 25, 2000 9:37 PM
12-170
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
Molded Case Circuit Breakers
12
Internal AccessoriesShunt Trip
Vol. 1, Ref. No. [0636]
Table 12-335. G-Frame Shunt Trip (LH 3-Pole only)
Note: Instruction Leaflet/FRED Number 15550
Note: G-Frame circuit breakers are factory sealed. Underwriters Laboratories requires that internal accessories be installed at the factory.Internal accessories are UL listed for factory installation under E7819.
Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation should be done before the circuit breaker is mounted and connected.
Table 12-336. E125 Shunt Trip
1 Suitable for use in ground fault applications.Note: Instruction Leaflet/FRED Number 29C152
Table 12-337. F-Frame Shunt Trip
2 Not listed with Underwriters Laboratories, for field installation.3 Pigtail wire size: 18 AWG (0.82 mm2).4 Standard pigtail lead exit location.5 120V AC marked suitable for ground fault protection devices.6 Standard mounting location.7 Not for use on 4-pole circuit breakers.Note: Instruction Leaflet/FRED Number 29C140
Table 12-338. J250 Shunt Trip
8 Suitable for use in ground fault applications.Note: Instruction Leaflet/FRED Number 29C152
Electrical Ratings CatalogNumber
PriceU.S. $
Suffix Number
AdderU.S. $Volts Frequency Amp
120240122424
50/60 Hz50/60 HzDCDC60 Hz
1.12.12.85.7–
1373D62G011373D62G021373D62G151373D62G161373D62G20
489.489.489.489.489.
S1S2S3S4S7
489.489.489.489.489.
Electrical Ratings CatalogNumber
PriceU.S. $Volts Frequency Hz
12 – 60110 – 240 1380 – 600
50/60, DC50/60, DC50/60
SNT060CPKSNT120CPKSNT480CPK
489.489.489.
Voltage Rating (AC Frequency = 50/60 Hz)
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits 2
18-Inch (457.2 mm) Pigtail Leads 3 Terminal Block Pigtail Leads Terminal Block
Same Side Rear 4 Opposite Side Same Side
Suffix Number
AdderU.S. $
Suffix Number
AdderU.S. $
Suffix Number
AdderU.S. $
Suffix Number
AdderU.S. $
Catalog Number
PriceU.S. $
Catalog Number
PriceU.S. $
Left-Pole Mounting AC/DC Ratings 12 – 24V AC or DC48 – 127V AC or 48 – 60V DC 5
208 – 380V AC or 110 – 127V DC415 – 600V AC or 220 – 250V DC
S01S05S09S13
489.489.489.489.
S02S06S10S14
489.489.489.489.
S03S07S11S15
489.489.489.489.
S04S08S12S16
489.489.489.489.
SNT1LP03KSNT1LP08KSNT1LP12KSNT1LP18K
489.489.489.489.
SNT1LT03KSNT1LT08KSNT1LT12KSNT1LT18K
489.489.489.489.
Right- or Neutral-Pole Mounting AC/DC Ratings 6
12 – 24V AC or DC48 – 127V AC or 48 – 60V DC 5
208 – 380V AC or 110 – 127V DC415 – 600V AC or 220 – 250V DC
S17S21S25S29
489.489.489.489.
S18S22S26S30
489.489.489.489.
S19S23S27S31
489.489.489.489.
S20S24S28S32
489.489.489.489.
SNT1RP03KSNT1RP08KSNT1RP12KSNT1RP18K
489.489.489.489.
SNT1RT03K 7
SNT1RT08K 7
SNT1RT12K 7
SNT1RT18K 7
489.489.489.489.
Electrical Ratings CatalogNumber
PriceU.S. $Volts Frequency Hz
12 – 60110 – 240 8380 – 600
50/60, DC50/60, DC50/60
SNT060CPKSNT120CPKSNT480CPK
489.489.489.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
TAB1206.fm Page 170 Wednesday, October 25, 2000 9:26 PM
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
12-19January 2001
Molded Case Circuit Breakers
12
10 – 225 AmperesF-Frame
Vol. 1, Ref. No. [0485]
ContentsDescription Page
Product Description . . . . . . . . 12-19
Technical Dataand Specifications . . . . . . . . 12-19
Dimension/Weights . . . . . . . . 12-20
Product Selection . . . . . . . . . . 12-20
F-Frame
Typical F-Frame Breaker
Product Description■ All F-Frame Circuit Breakers are
HACR rated.■ All circuit breakers 10 through
50 amperes are suitable for HID (high intensity discharge) use.
■ All F-Frame circuit breakers are suitable for reverse feed use.
Technical Data and SpecificationsTable 12-28. UL489 Interrupting Capacity Ratings
1 DC ratings apply to substantially non-inductive circuits.2 2-pole circuit breaker, or two poles of 3-pole circuit breaker.3 Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
Table 12-29. IEC 157-1 (P1) Interrupting Capacity Ratings (P1)
4 DC ratings apply to substantially non-inductive circuits.5 2-pole circuit breaker, or two poles of 3-pole circuit breaker.6 Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.
Circuit Breaker Type
Number of Poles
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts AC (50/60 Hz) Volts DC 1
240 277 480 600 125 250 23
ED EDH EDC
2, 3 2, 3 2, 3
65 100200
———
———
———
101010
———
EHD 12, 3
—18
14—
—14
——
10—
—10
FDB 2, 3, 4 18 — 14 14 — 10
FD 12, 3, 4
—65
25—
—25
—18
10—
—10
HFD 12, 3, 4
—100
65—
—65
—25
10—
—22
FDC 2, 3, 4 200 — 100 35 — 22
Circuit Breaker Type
Number of Poles
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts AC (50/60 Hz) Volts DC 4
220, 240 380, 415 440 500 125 250 56
ED EDH EDC
2, 32, 32, 3
65100200
———
———
———
101010
———
FDB 2, 3, 4 18 14 14 14 — 10
FD 12, 3, 4
25 65
—35
—35
—18
10—
—10
HFD 12, 3, 4
65 100
—65
—65
—25
10—
—22
FDC 2, 3, 4 200 100 100 35 — 22