Molded Case Circuit Breakers MCCB - UL489

Upload: others

Post on 05-Sep-2021

27 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

Molded Case Circuit BreakersMCCB - UL489

Page 2: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

2 MCCB - EMB Series

Summary

Introduction 03

External Accessories 12

Trip Curves 17

Installation and Connections 15

Main Characteristics 04

Selection Guide 05

Accessories 06

Internal Accessories 10

Technical Data 14

Dimensions - Inch (mm) 37

Molded Case Circuit Breakers UL 489 Listed - EMB Line

Page 3: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

3MCCB - EMB Series

UL Interrupting Rating (kA)

Main Characteristics

MCCB EMB-F1H EMB-F2H EMB-F3H EMB-F4H

Type X X X X

240 V ac 50 80 80 80

480Y/277 V ac 14 35 - -

480 V ac - - 35 35

Introducing the EEC's new generations of Molded Case Circuit Breakers now available with UL 489 certification. With its four compact frames, the EMB series provides protection from 20 to 600 amperes: 100% rated.

The EMB series also counts with three levels of short circuit interrupting capacity, and common1) internal accessories that simplify field installation and minimize inventory variations.

EMB MOLDED CASE CIRCUIT BREAKERS UL 489 LISTED

Page 4: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

4 MCCB - EMB Series

Main Characteristics

Current Ratings and Trip Units

Note: 1) Circuit breakers with rated currents of 20 and 25 A, the magnetic trip point is 300 A.

EMB-F1HIn 20...100

EMB-F3HIn 200...400

EMB-F4HIn 325...600

Reference code Rated current In (A) Trip unit Curve

EMB-F1H20, 25, 30, 40, 50, 60, 70, 80, 90, 100

Fixed thermal Fixed magnetic1) (10 x In)Im

46

8

1012

2.7

.8

.9

.951

.65

6

7

810

4

.4

.5 3

2

I

x Inx In x Ir

L S

IiIr Is

.3.4

.1

.2.3

.2

.1

.4

70% 105%

3

1.6

12

18

6 at 8xIr (s)tr ts

2I t OFF

2I t ON

at 6xIr (s)

Is

Ii

ts

tr

Ir

Ir

Im

IrIr

Curvas para Catálogo( Linha DW 2013 )

EMB-F2H80-100, 100-125, 120-150,

160-200, 200-250Adjustable thermal (0.8...1 x In) Fixed magnetic (10 x In)

rI

EMB-F3H160-200, 180-225, 200-250, 220-275, 240-300, 260-325,

280-350, 320-400Adjustable thermal (0.8...1 x In) Adjustable magnetic (5...10 x In)

Im

46

8

1012

2.7

.8

.9

.951

.65

6

7

810

4

.4

.5 3

2

I

x Inx In x Ir

L S

IiIr Is

.3.4

.1

.2.3

.2

.1

.4

70% 105%

3

1.6

12

18

6 at 8xIr (s)tr ts

2I t OFF

2I t ON

at 6xIr (s)

Is

Ii

ts

tr

Ir

Ir

Im

IrIr

Curvas para Catálogo( Linha DW 2013 )

t

i

EMB-F4H228-325, 245-350, 280-400, 315-450, 350-500, 385-550,

420-600Adjustable thermal (0,7...1 x In) Adjustable magnetic (5...10 x In)

Im

46

8

1012

2.7

.8

.9

.951

.65

6

7

810

4

.4

.5 3

2

I

x Inx In x Ir

L S

IiIr Is

.3.4

.1

.2.3

.2

.1

.4

70% 105%

3

1.6

12

18

6 at 8xIr (s)tr ts

2I t OFF

2I t ON

at 6xIr (s)

Is

Ii

ts

tr

Ir

Ir

Im

IrIr

Curvas para Catálogo( Linha DW 2013 )

t

i

EMB-F2HIn 80...250

Page 5: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

5MCCB - EMB Series

Selection Guide

EMB-F1H for Distribution - Premium 100% Rated - Fixed Thermal and Fixed Magnetic Trip Unit

EMB-F2H for Distribution - Premium 100% Rated - Adjustable Thermal and Fixed Magnetic Trip Unit

Rated current (A) Magnetic trip point (A)Interrupting ratings (kA) Reference code

240 V ac 480Y/277 V ac 3 poles20 300 50 14 EMB-F1H-020-3PX25 300 50 14 EMB-F1H-025-3PX30 300 50 14 EMB-F1H-030-3PX40 400 50 14 EMB-F1H-040-3PX50 500 50 14 EMB-F1H-050-3PX60 600 50 14 EMB-F1H-060-3PX70 700 50 14 EMB-F1H-070-3PX80 800 50 14 EMB-F1H-080-3PX90 900 50 14 EMB-F1H-090-3PX100 1000 50 14 EMB-F1H-100-3PX

Current range (A) Magnetic trip point (A)Interrupting ratings (kA) Reference code

240 V ac 480Y/277 V ac 3 poles80-100 1000 80 35 EMB-F2H-100-3PX100-125 1250 80 35 EMB-F2H-125-3PX120-150 1500 80 35 EMB-F2H-150-3PX160-200 2000 80 35 EMB-F2H-200-3PX200-250 2500 80 35 EMB-F2H-250-3PX

Notes: Wiring terminals (lugs) built-in for EMB-F1H and supplied as standard with EMB-F2H, EMB-F3H and EMB-F4H. Lugs are also available as an accessory for EMB-F2H, EMB-F3H and EMB-F4H, see the section Accessories.

EMB-F3H for Distribution - Premium 100% Rated - Adjustable Thermal and Magnetic Trip Unit

Current range (A) Magnetic trip point (A)Interrupting ratings (kA) Reference code

240 V ac 480 V ac 3 poles160-200 1600-2000 80 35 EMB-F3H-200-3PX180-225 1800-2250 80 35 EMB-F3H-225-3PX200-250 2000-2500 80 35 EMB-F3H-250-3PX220-275 2200-2750 80 35 EMB-F3H-275-3PX240-300 2400-3000 80 35 EMB-F3H-300-3PX260-325 2600-3250 80 35 EMB-F3H-325-3PX280-350 2800-3500 80 35 EMB-F3H-350-3PX320-400 3200-4000 80 35 EMB-F3H-400-3PX

EMB-F4H for Distribution - Standard 100% Rated - Adjustable Thermal and Magnetic Trip Unit

Current range (A) Magnetic trip point (A)Interrupting ratings (kA) Reference code

240 V ac 480 V ac 3 poles227.5-325 1625-3250 80 35 EMB-F4H-325-3PX245-350 1750-3500 80 35 EMB-F4H-350-3PX280-400 2000-4000 80 35 EMB-F4H-400-3PX315-450 2250-4500 80 35 EMB-F4H-450-3PX350-500 2500-5000 80 35 EMB-F4H-500-3PX385-550 2750-5500 80 35 EMB-F4H-550-3PX420-600 3000-6000 80 35 EMB-F4H-600-3PX

Page 6: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

6 MCCB - EMB Series

Overview of EMB-F1H and Accessories

Accessories

1 - Molded case circuit breaker EMB-F1H 2 - Auxiliary contact block EMB-AX, alarm auxiliary contact block EMB-AL, alarm/auxiliary contact block EMB-ALX 3 - Undervoltage-trip release EMB-UVT, shunt trip release EMB-SHT 4 - Wiring terminal (lug) PC (built-in 6 units) 5 - Mechanical interlock EMB-F1-MITL 6 - Lock-OFF device EMB-F1-PLK 7 - Panel door rotary operating handle EMB-F1-RHB-N4X (Greyb/Black), EMB-F1-RHY-N4X (Yellow/Red) 8 - Panel door rotary operating handle EMB-F2-RHB-N4X (Greyb/Black), EMB-F2-RHY-N4X (Yellow/Red) 9 - DIN rail base EMB-F1-DIN

32

1

8

7

6

10

4

5

Page 7: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

7MCCB - EMB Series

8

7

Overview of EMB-F2H and Accessories

Accessories

3

1

2

4

5

6

1 - Molded case circuit breaker EMB-F2H 2 - Auxiliary contact block EMB-AX, alarm auxiliary contact block EMB-AL, alarm/auxiliary contact block EMB-ALX 3 - Undervoltage-trip release EMB-UVT, shunt trip release EMB-SHT 4 - Wiring terminal (lug) PC (built-in 6 units) 5 - Mechanical interlock EMB-F2-MITL 6 - Lock-OFF device EMB-F2-PLK 7 - Panel door rotary operating handle EMB-F1-RHB-N4X (Greyb/Black), EMB-F1-RHY-N4X (Yellow/Red) 8 - Panel door rotary operating handle EMB-F2-RHB-N4X (Greyb/Black), EMB-F2-RHY-N4X (Yellow/Red)

Page 8: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

8 MCCB - EMB Series

Accessories

Overview of EMB-F3H and Accessories

3

1

2

4

5

6

7

1 - Molded case circuit breaker EMB-F3H 2 - Auxiliary contact block EMB-AX, alarm auxiliary contact block EMB-AL, alarm/auxiliary contact block EMB-ALX 3 - Undervoltage-trip release EMB-UVT, shunt trip release EMB-SHT 4 - Wiring terminal (lug) PC (built-in 6 units) 5 - Mechanical interlock EMB-F3-MITL 6 - Lock-OFF device EMB-F3-PLK 7 - Panel door rotary operating handle EMB-F3-RHB-N4X (Greyb/Black), EMB-F3-RHY-N4X (Yellow/Red)

Page 9: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

9MCCB - EMB Series

3

6

4

2

7

Overview of EMB-F4H and Accessories

Accessories

1 - Molded case circuit breaker EMB-F4H 2 - Wiring terminal (lug) PC (built-in 6 units) 3 - Auxiliary contact block EMB-AX, alarm auxiliary contact block EMB-AL, alarm/auxiliary contact block EMB-ALX 4 - Undervoltage-trip release EMB-UVT, shunt trip release EMB-SHT 5 - Mechanical interlock EMB-F4-MITL 6 - Lock-OFF device EMB-F4-PLK 7 - Panel door rotary operating handle EMB-F4-RHB-N4X (Greyb/Black), EMB-F4-RHY-N4X (Yellow/Red)

87

5

Page 10: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

10 MCCB - EMB Series

Internal Accessories

EMB-AX - Auxiliary Contact Block J Indicates the main contacts status open (OFF) / closed (ON) through a changeover contacts (SPDT or form C contact)

EMX-AL - Alarm Contact Block J Indicates circuit breaker’s trip due to overload, short-circuit, shunt trip or undervoltage-trip release conditions through a changeover contact (SPDT or form C contact)

J The contact opens when the circuit breaker is reset J Offers provisions for audio or visual indication of the under the conditions described above

EMB-AXL - Auxiliary and Alarm Contact Set J Ensemble comprised of an auxiliary contact + alarm contact. The EMB-AXL block performs the 2 functions above in different contacts in a single set.

Internal accessory Number of contactsReference code

EMB-F1H EMB-F2H EMB-F3H EMB-F4H

Auxiliary contact block EMB-AX1 changeover EMX-AX-1C

EMX-AX-2C2 changeover

Alarm contact block EMB-AL 1 changeover EMX-AL-1C

Auxiliary and alarm contact - EMB-AXL 1BC + 1AL EMX-AXL-1C

Electrical characteristics

Rated voltage Type of load Switching capacity (A)

125 V ac Resistive 6

250 V ac Resistive 6

Notes: Use EMB-AXL block when applications require auxiliary contact and alarm contact fitted in the same circuit breaker. Not applicable for motor switching.

Auxiliary and Alarm Contact BlocksThe auxiliary and alarm contact blocks have the function to signal remotely the status of circuit breaker’s power contacts. There are 3 types of auxiliary and alarm contact blocks:

Auxiliary and Alarm Contact BlocksEMX-AX, EMX-AL and EMX-AXL contacts already come with built-in terminal blocks. These terminal blocks accept wires of 20 to 16 AWG (0.5 to 1.5 mm2) and tightening torque of 6.9 lb.in (0.8 N.m).

Wiring Diagrams

ON OFF TRIP

EMB-AX

EMB-AL

1112221424

21

81

82

84

11

1222

1424

21

81

82

84

Page 11: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

11MCCB - EMB Series

Maximum Configurations - Internal AccessoriesInternal accessory EMB-F1H EMB-F2H EMB-F3H EMB-F4H

Auxiliary contact block 2 11) 2 11) 2 11) 2 11) 2 11) 2 11) 4 3 4 3

Alarm contact block 0 11) 0 11) 0 11) 0 11) 0 11) 0 11) 0 1 0 1

Shunt release 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0

Undervoltage release 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

Internal Accessories

Shunt and Undervoltage ReleaseVoltage releases function to trip remotely the circuit breaker. They are often used for remote emergency stop purpose.

EMB-SHT - Shunt Release J When energized by a pulse or maintained signal of voltage, the shunt release trips the circuit breaker (trip position). The shunt release works from 70 to 110% of the rated voltage (0.70 x Un <Ue <1.1 x Un)

J This release features a device to keep it not energized after the tripping pulse

Internal accessory Frame Size Reference code

Undervoltage release BS EMB-F1H, EMB-F2H EMB-UVT-2

Shunt release BD EMB-F1H, EMB-F2H EMB-SHT-2

Undervoltage release BS EMB-F3H EMB-UVT-3

Shunt release BD EMB-F3H EMB-SHT-3

Under voltage release BD EMB-F4H EMB-UVT-4

Shunt release BD EMB-F4H EMB-SHT-4

Using EMB-SHT and EMB-UVT ReleasesEMB-SHT and EMB-UVT releases already come with built-in terminal blocks. These terminal blocks accept wires of 20 to 16 AWG (0.5 to 1.5 mm2) and tightening torque of 6.9 lb.in (0.8 N.m). After EMB-SHT and EMB-UVT releases have operated, the circuit breaker have to be reset before being closed again.

Wiring Diagrams

Note: Other voltages upon request.

To Complete the Reference Code, Replace "" with the Appropriate Voltage CodeN O I A C

24 V ac/dc 48 V ac/dc 60 V ac/dc 110-130 V ac/dc 220-250 V ac/dc

EMB-UVT - Undervoltage Release J Trips the circuit breaker when the voltage drops below 35% of the rated voltage (Ue <0.35 x Un)

J When voltage is between 35 to 70% of the rate voltage, it may open the circuit breaker (0.35 x Un <Ue <0.7 x Un)

J After the operation of BS release, circuit breaker can only be closed if supply voltage is above 85% of the rated voltage (Ue >0.85 x Un)

J The undervoltage release along with an emergency stop push button makes possible the fail-safe operation of the circuit breaker

Note: 1) Use EMB-AXL contact block when applications require auxiliary contact and alarm contact fitted in the same circuit breaker.

Page 12: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

12 MCCB - EMB Series

External Accessories

J When in ON position, panel door cannot be opened, unless a tool is used to bypass the panel door locking system, allowing thermometry of the panel.

J Circuit breaker and panel door padlocking in OFF position using 1 to 3 padlocks.

Panel Door Operating Handles

Panel Door Operating Handles (NEMA 4X/IP66)

Handle (NEMA 4X/IP66)

One Set Includes: Handle + Shaft + Mechanism

Notes: 1) Padlocks 0.16 up to 0.31 in may be fit to the handles.2) Sold separately only. It is not sold assembled on the circuit breaker.

Coding EMB F1 RHY N4X

EMB: panel door operating handle

Description Circuit breaker Shaft in (mm)Length of handle

in (mm)Handle colour

EMB-F1-RHY-N4X EMB-F1 18.11 (460) 2.42 (61.6) Red and yellowEMB-F2-RHY-N4X EMB-F1 18.11 (460) 4.13 (105) Red and yellowEMB-F2-RHY-N4X EMB-F2 18.11 (460) 4.13 (105) Red and yellowEMB-F3-RHY-N4X EMB-F3 18.11 (460) 4.13 (105) Red and yellowEMB-F4-RHY-N4X EMB-F4 18.11 (460) 6.22 (158) Red and yellowEMB-F1-RHB-N4X EMB-F1 18.11 (460) 2.42 (61.6) Grey/BlackEMB-F2-RHB-N4X EMB-F1 18.11 (460) 4.13 (105) Grey/BlackEMB-F2-RHB-N4X EMB-F2 18.11 (460) 4.13 (105) Grey/BlackEMB-F3-RHB-N4X EMB-F3 18.11 (460) 4.13 (105) Grey/BlackEMB-F4-RHB-N4X EMB-F4 18.11 (460) 6.22 (158) Grey/Black

RHY: Yellow/Red OperatorRHB: Grey/Black OperatorF1: Frame Size

F2: Frame SizeF3: Frame SizeF4: Frame Size

N4X: NEMA 4X / IP66 Operator Type

Changeover Device - Mechanical InterlockManual-operated changeovers are used to make safe switching of two different circuits.

External accessory MCCB Reference code

Mechanical interloc

EMB-F1H EMB-F1-MITL

EMB-F2H EMB-F2-MITL

EMB-F3H EMB-F3-MITL

EMB-F4H EMB-F4-MITL

Mechanical Interlock J Provides safe operation in a manual-operated changeover system J Makes the mechanical interlock of 2 circuit breakers of the same frame size, preventing both MCCBs to be in ON position

J Interlock is assembled directly to the front cover of the circuit breakers J It can be padlocked in 2 positions: MCCB1 ON and MCCB2 OFF, MCCB1 OFF and MCCB2 ON J The interlock allows padlocks with diameters of Ø0.16...0.31 inches (4...8 mm) J It is possible to interlock 3 MCCBs side-by-side using 2 interlocks J Padlocks are not supplied

Page 13: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

13MCCB - EMB Series

External Accessories

Accessory for Connection and InstallationDepending on the application and local standards, the MCCB may be installed and connected through bus bars or cables. Given these requirements, the EMB range of circuit breakers have the specific connection accessory to comply with.

External accessory

Spare part(units)

MCCBMinimum cross-section

(AWG / mm²)Maximum cross-section

(AWG / mm²)Tightening torque

(lb.in / N.m)Reference code

Wiring terminal 3

EMB-F2H 4 / 25 (1 cable) 250 kcmil / 120 (1 cable) 220 / 25 EMB-LK-F2

EMB-F3H 3/0 / 95 (1 cable) 500 kcmil / 240 (1 cable) 265 / 35 EMB-LK-F3

EMB-F4H 400 kcmil / 240 (1 cable) or 3/0 / 95 (2 cables) 350 kcmil / 185 (2 cables) 310 / 55 EMB-LK-F4

External accessory MCCB Reference code

DIN rail base EMB-F1H EMB-DIN

EMB-LK Wiring Terminals (Lugs) J Provides the means for connecting the circuit breaker to the power source and the load J PC is supplied with 3 pieces that are suitable for either line or load terminals J Built-in on EMB-F1 in the 6 terminals J Lugs are supplied with 6 units for EMB-F2, EMB-F3 and EMB-F4 (supplied as standard) J Pack with 3 units for spare parts

DIN Rail Base J Quick assembly of EMB-F1H on 35 mm DIN rails J Fast replacement when panel is under maintenance

Lock-OFF Devices

External accessory MCCB Reference code

Lock-OFF device PLW

EMB-F1H EMB-F1-PLK

EMB-F2H EMB-F2-PLK

EMB-F3H EMB-F3-PLK

EMB-F4H EMB-F4-PLK

PLK Lock-OFF Devices J The PLW is a fixed-type device that is installed on the front of the MCCB ensuring the MCCB locking in OFF position J It can be padlocked using 1 to 3 padlocks, allowing padlocks with diameters of Ø0.16...0.31 inches (4...8 mm) J Padlocks are not supplied

Page 14: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

14 MCCB - EMB Series

Technical Data

Reference code EMB-F1H EMB-F2H EMB-F3H EMB-F4H

Frame size 100 250 400 600

Electrical characteristics according to UL 489

Rated operational voltage - Eu V ac (60 Hz) 480Y/277 480Y/277 480 480

Maximum rated continuous current - In (40 °C) A 100 250 400 600

MCCB rating design 100%1)

Rated current - In (40 °C) A20, 25, 30, 40, 50, 60,

70, 80, 90, 10080-100, 100-125,

120-150,160-200, 200-250

160-200, 180-225, 200-250, 220-275, 240-300, 260-325, 280-350, 320-400

227.5-325, 245-350, 280-400, 315-450, 350-500, 385-550,

420-600

Number of poles 3 3 3 3

Short-circuit breaking capacity levels H H H H

UL interrupting rating - max RMS symmetrical

kA rms - - - -

240 V ac 50 80 80 80

480Y/277 V ac 14 35 - -

480 V ac - - 35 35

Mechanical lifespan (C-O)Number of operations 10,000 6,000 6,000 6,000

Operations per hour 360 240 240 240

Electrical lifespan (C-O) @ 480 V acNumber of operations 6,000 1,000 1,000 1,000

Operations per hour 360 240 240 240

Protection

Against short-circuit & overload (fixed thermomagnetic) Yes No No No

Against short-circuit & overload (adjustable thermal and fixed magnetic) No Yes No No

Against short-circuit & overload (adjustable thermal and magnetic) No No Yes Yes

Accessories

Internal

Auxiliary contact Yes Yes Yes Yes

Alarm contact Yes Yes Yes Yes

Auxiliary and alarm contacts Yes Yes Yes Yes

Shunt trip release Yes Yes Yes Yes

Undervoltage-trip release Yes Yes Yes Yes

External

Mechanical interlock Yes Yes Yes Yes

Lock-OFF device Yes Yes Yes Yes

Escutcheons Yes Yes Yes Yes

Wiring terminal (lug) Built-in Standard Standard Standard

Handles Panel door rotary operating handle Yes Yes Yes Yes

Installation and connections

Suitable for reverse connection Yes Yes Yes Yes

Cables - Cu2)

Maximum cross-section 3 AWG 250 kcmil 500 kcmil 400 kcmil

Minimum cross-section 10 AWG 4 AWG 3/0 AWG 3/0 AWG

Tightening torque lb.in (N.m) 57.5 (6.5) 220 (25) 265 (35) 310 (55)

Busbar Tightening torque lb.in (N.m) - 70 (8) 175 (20) 175 (20)

Dimensions (W x D x H) Inches (mm)3.07 x 2.87 x 6.30

(78 x 73 x 160)4.13 x 3.15 x 7.87 (105 x 80 x 200)

4.22 x 3.9 x 12.72 (107 x 99 x 323)

8.27 x 3.9 x 12.72 (210 x 99 x 323)

Weight 3 poles Pounds (kg) 2.09 (0.95) 3.97 (1.8) 7.85 (3.56) 16.31 (7.4)

Notes: 1) For EMB-F1H: suitable for continuous operation at 100 percent of rating only if used in a circuit breaker enclosure in a cubicle space 23.6 x 15.7 x 7.9 inches (600 x 400 x 200 mm) or equivalent. For EMB-F2H: suitable for continuous operation at 100 percent of rating only if used in a circuit breaker enclosure in a cubicle space 31.5 x 23.6 x 11.8 inches (800 x 600 x 300 mm) or equivalent. For EMB-F3H and EMB-F4H: suitable for continuous operation at 100 percent of rating only if used in a circuit breaker enclosure in a cubicle space 47.2 x 23.6 x 15.8 inches (1,200 x 600 x 400 mm) or equivalent.

2) Use only 90 ºC rated wire with ampacity based on 75 °C rated conductors.

Page 15: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

15MCCB - EMB Series

Installation and Connections

Minimum Mounting Distances

EMB-

F1H

EMB-

F2H

EMB-

F3H

EMB-

F4H

Recommended mounting distances (inch / mm)

B

AC

1.97 / 50 1.97 / 50 2.76 / 70 3.94 / 100

0.79 / 20 0.79 / 20 1.18 / 30 1.18 / 30

0.79 / 20 0.79 / 20 1.18 / 30 1.18 / 30

Recommended distances between circuit breakersfor side by side assembly (inch / mm)

D

0.394 / 10 0.394 / 10 0.394 / 10 0

Recommended distances between circuit breakersfor vertical assembly (inch / mm)

E

3.54 / 90 5.91 / 150 7.09 / 180 7.87 / 200

Dimensions of fixing screw tothe plate (inch / mm)

M4 x 2.99 / 76 (2 pieces) M4 x 2.99 / 76 (2 pieces) M5 x 1.97 / 50 (4 pieces) M5 x 60 x 4

Surpass of the fixing screw inrelation to the circuit breaker (inch / mm)

H

0.315 / 8 0.236 / 6 0.59 / 15 0.59 / 15

Tightening torque - fixing screw (lb.in / N.m) 35.2 / 4 35.2 / 4 25 / 2.5 26.5 / 3

Page 16: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

16 MCCB - EMB Series

Installation and Connections

Thermal DissipationDistribution MCCB

EMB-F1HIn (A) 20 25 32 40 50 63 70 80 90 100

Watts/pole 1 2 4 4 5 8 4 5 6 7

EMB-F2HIn (A) 100 125 160 200 250

Watts/pole 14 19 17 14 20

EMB-F3HIn (A) 200 250 320 400

Watts/pole 14 20 19 30

EMB-F4HIn (A) 320 400 500 600

Watts/pole 19 30 38 47

Temperature derating

10 °C 15 °C 20 °C 25 °C 30 °C 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C

EMB-F1H 1.16 1.12 1.09 1.07 1.02 1.02 1.00 0.97 0.95 0.91 0.88

EMB-F2H 1.15 1.13 1.10 1.08 1.05 1.02 1.00 0.98 0.95 0.92 0.88

EMB-F3H 1.15 1.13 1.10 1.08 1.05 1.02 1.00 0.98 0.95 0.92 0.88

EMB-F4H 1.15 1.13 1.11 1.08 1.05 1.03 1.00 0.97 0.94 0.91 0.88

Altitude derating

Altitude (m) In Ue (V)

2,000 100% 100%

3,000 98% 88%

4,000 93% 78%

5,000 90% 68%

Conductor Installation - BarsReference code Tightening torque (lb.in / N.m) Conductor - Inch (mm)

EMB-F2H 70 / 8

1.55 A/mm²

Max 0.31 (8

)

1,000 A/in²

0.370.

78 (1

9.5)

0.47(12)Max 0.94 (24)

Ø0.33 (Ø8.5)

EMB-F3H 175

1.55 A/mm²

Max 0.

47 (1

2)

1,000 A/in²

0.47

1.06

(27)

0.47(12)Max 0.94 (24)

Ø0.35 (Ø9)

EMB-F4H 175

1,55 A/mm²1000 A/in²

Ø9Ø0.35

301.18

13 (MAX)0.51

501.97

25

0.98

1.55 A/mm²1,000 A/in²

301.18

25

500.98

1.97

13 (Máx.)0.51

(Ø9)

Ø0.35

(9.5

)

Page 17: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

17MCCB - EMB Series

Trip Curves

EMB-F1H - Fixed Thermal and Fixed Magnetic (20…100 A)

1 1.3 2 3 4 5 6 7 8 10 12 15 20 30 40 500.01

0.02

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

2000

5000

10000

20000

t (s)

x In

25 A: 12 x In

From 30 to 100 A: 10 x In

20 A: 15 x In

Characteristic trip curve.The curves shown are for cold state and three pole loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%.

DWB16020,000

10,000

5,000

2,000

1,000

500

200

100

50

20

t (s)

x In

From 30 to 100 A : 10 x In

25 A: 12 x In 20 A: 15 x In

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

1 1.3 2 3 4 5 6 7 8 10 12 15 20 30 40 50

Characteristic trip curve.The curves shown are for cold state and three pole

loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.

For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%

EMB-F1H

Page 18: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

18 MCCB - EMB Series

EMB-F2H - Adjustable Thermal and Fixed Magnetic (80…250 A)

Trip Curves

1 1.3 2 3 4 5 6 7 8 10 20 30 40 500.01

0.02

0.05

0.1

0.2

0.5

1

2

5

10

20

50

100

200

500

1000

2000

5000

10000

20000

t(s)

x In

10 x In

Characteristic trip curve.The curves shown are for cold state and three pole loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%.

Maximum current adjustment: 1 x In

Minimum current adjustment: 0.8 x In

DWB25020,000

10,000

5,000

2,000

1,000

500

200

100

50

20

t (s)

x In

10 x In

Minimum current adjustment: 0.8 x In

Maximum current adjustment: 1 x In

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

1 1.3 2 3 4 5 6 7 8 10 20 30 40 50

Characteristic trip curve.The curves shown are for cold state and three pole

loaded. For hot state the time values areapproximately 25% of the presented on the cold

state curve.For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%.

EMB-F2H

Page 19: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

19MCCB - EMB Series

1 1,3 2 3 4 5 6 7 8 10 20 30 40 500,01

0,02

0,05

0,1

0,2

0,5

1

2

5

10

20

50

100

200

500

1000

2000

5000

10000

20000

t (s)

x In

Maximum magnetic adjustment: 10 xInMinimum magnetic

adjustment: 5 xIn

DWB400 Characteristic trip curve.The curves shown are for cold state and three pole loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.For one pole load, the time may rise up 20%.For two pole load, the time may rise up 10%.

Maximum current adjustment: 1 xIn

Minimum current adjustment: 0.8 xIn

Trip Curves

EMB-F3H - Adjustable Thermal and Magnetic (200...400 A)

20,000

10,000

5,000

2,000

1,000

500

200

100

50

20

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

t (s)

1 1.3 2 3 4 5 6 7 8 10 20 30 40 50

x In

Characteristic trip curve.The curves shown are for cold state and three pole

loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.

For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%

Maximum current adjustment: 1 x ln

Minimum current adjustment: 0.8 x ln

Minimum magnetic adjustment: 5 x ln

Maximum magnetic adjustment: 10 x ln

EMB-F3H

Page 20: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

20 MCCB - EMB Series

1 1,3 2 3 4 5 6 7 8 10 20 30 40 500,01

0,02

0,05

0,1

0,2

0,5

1

2

5

10

20

50

100

200

500

1000

2000

5000

10000

20000

t(s)

x In

DWB600 Characteristic trip curve.The curves shown are for cold state and three pole loaded. For hot state the time values are

approximately 25% of the presented on the cold state curve.

For one pole load, the time may rise up 20%.For two pole load, the time may rise up 10%.

Maximum current adjustment: 1 xIn

Minimum current adjustment: 0.7 xIn

Maximum magnetic adjustment: 10 xIn

Minimum magnetic adjustment: 5 xIn

Trip Curves

EMB-F4H - Adjustable Thermal and Magnetic (200...600 A)

20,000

10,000

5,000

2,000

1,000

500

200

100

50

20

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

t (s)

1 1.3 2 3 4 5 6 7 8 10 20 30 40 50

x In

Characteristic trip curve.The curves shown are for cold state and three pole

loaded. For hot state the time values are approximately 25% of the presented on the cold state curve.

For one pole load, the time may rise up to 20%.For two pole load, the time may rise up to 10%

Maximum current adjustment: 1 x ln

Minimum current adjustment: 0.7 x ln

Minimum magnetic adjustment: 5 x ln

Maximum magnetic adjustment: 10 x ln

EMB-F4H

Page 21: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

21MCCB - EMB Series

EMB-F1H - Short-Circuit Limiting Curves @ 240 VAC

Trip Curves

1 2 3 4 5 7 10 20 30 40 50 70 1001

2

3

4

5

7

10

20

30

40

50

J

C

Ip (k

Â)

Is (kA)

DWB160 - UL 240 V

50

40

30

20

10

Ip (k

Â)

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

EMB-F1H - UL 240 VAC

Page 22: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

22 MCCB - EMB Series

Trip Curves

EMB-F1H - Short-Circuit Limiting Curves @ 480Y/277 VAC

1 2 3 4 5 7 10 201

2

3

4

5

7

10

20

30

JC

Ip (k

Â)

Is (kA)

DWB160 - UL 480Y/277 V ac

30

20

10

7

5

4

3

2

1

Ip (k

Â)

Is (kA)

1 2 3 4 5 7 10 20

EMB-F1H - UL 480Y/277 VAC

Page 23: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

23MCCB - EMB Series

Trip Curves

EMB-F2H - Short-Circuit Limiting Curves @ 240

1 2 3 4 5 7 10 20 30 40 50 70 100 2001

2

3

4

5

7

10

20

30

40

50

PJ

Ip (k

Â)

Is (kA)

DWB250 - UL 240V50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50

70 100Is (kA)

Ip (k

Â)

200

EMB-F2H - UL 240 VAC

Page 24: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

24 MCCB - EMB Series

Trip Curves

EMB-F2H - Short-Circuit Limiting Curves @ 480Y/277 VAC

1 2 3 4 5 7 10 20 30 40 50 70 1001

2

3

4

5

7

10

20

30

40

50

P

J

Ip (k

Â)

Is (kA)

DWB250 -UL 480Y/277 V ac

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

Ip (k

Â)

EMB-F2H - UL 480Y/277 VAC

Page 25: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

25MCCB - EMB Series

Trip Curves

EMB-F3H - Short-Circuit Limiting Curves @ 240 VAC

1 2 3 4 5 7 10 20 30 40 50 70 100 2001

2

3

4

5

7

10

20

30

40

50P

J

Ip (k

Â)

Is (kA)

DWB400 - UL 240V

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

Ip (k

Â)

200

EMB-F3H - UL 240 VAC

Page 26: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

26 MCCB - EMB Series

Trip Curves

EMB-F3H - Short-Circuit Limiting Curves @ 480 VAC

1 2 3 4 5 7 10 20 30 40 50 70 1001

2

3

4

5

7

10

20

30

40

50

P

J

Ip (k

Â)

Is (kA)

DWB400 - UL 480V

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

Ip (k

Â)

EMB-F3H - UL 480 VAC

Page 27: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

27MCCB - EMB Series

Trip Curves

EMB-F4H - Short-Circuit Limiting Curves @ 240 VAC

1 2 3 4 5 7 10 20 30 40 50 70 100 2001

2

3

4

5

7

10

20

30

40

50

P

Ip (k

Â)

Is (kA)

DWB600 - UL 240V50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

200

EMB-F4H UL 240 VAC

Ip (k

Â)

Page 28: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

28 MCCB - EMB Series

Trip Curves

EMB-F4H - Short-Circuit Limiting Curves @ 480 VAC

1 2 3 4 5 7 10 20 30 40 50 70 1001

2

3

4

5

7

10

20

30

40

50P

Ip (k

Â)

Is (kA)

DWB600 - UL 480V50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100

Is (kA)

Ip (k

Â)

EMB-F4H UL 480 VAC

Page 29: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

29MCCB - EMB Series

Trip Curves

EMB-F1H - I2t @ 240 VAC

1 2 3 4 5 7 10 20 25 30 40 50 701

2

3

45

7

10

20

30

4050

70

100

200

300

400500

700

1000

JC

I²t (1

0³ A

²s)

Is (kA)

DWB160 - UL 240 V1,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10

Is (kA)

20 25 30 40 50 70

I2 t (1

03 A

2 s)

EMB-F1H - UL 240 VAC

Page 30: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

30 MCCB - EMB Series

Trip Curves

EMB-F1H - I2t @ 480Y/277 VAC

1 2 3 4 5 7 10 14 201

2

3

45

7

10

20

30

4050

70

100

200

300

400500

700

1000

J

C

I²t (1

0³ A

²s)

Is (kA)

DWB160 - UL 480Y/277 V ac1,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 14 20

I2 t (1

03 A

2 s)

Is (kA)

EMB-F1H - UL 480Y/277 VAC

Page 31: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

31MCCB - EMB Series

Trip Curves

EMB-F2H - I2t @ 240 VAC

1 2 3 4 5 7 10 20 30 40 50 70 100 1501

2

3

45

7

10

20

30

4050

70

100

200

300

400500

700

1000

2000

PJ

I²t (1

0³ A

²s)

Is (kA)

DWB250 - UL 240V2,000

1,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

11 2 3 4 5 7 10 20 30 40 50 70 100 150

I2 t (1

03 A

2 s)

Is (kA)

EMB-F2H - UL 240 VAC

Page 32: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

32 MCCB - EMB Series

Trip Curves

EMB-F2H - I2t @ 480Y/277 VAC

1 2 3 4 5 7 10 14 20 30 35 501

2

3

45

7

10

20

30

4050

70

100

200

300

400500

700

1000

2000P

J

I²t (1

0³ A

²s)

Is (kA)

DWB250 - UL 480Y/277 V ac2,000

1,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 14 20 30 35 50

I2 t (1

03 A

2 s)

Is (kA)

EMB-F2H - UL 480Y/277 VAC

Page 33: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

33MCCB - EMB Series

Trip Curves

EMB-F3H - I2t @ 240 VAC

1 2 3 4 5 7 10 20 30 40 50 70 100 1501

2

345

7

10

20

304050

70

100

200

300400500

700

1000

2000

5000

PJ

I²t (1

0³ A

²s)

Is (kA)

DWB400 - UL 240V5,000

2,000

1,000

400

500

700

300

200

100

70

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100 150

I2 t (1

03 A

2 s)

Is (kA)

EMB-F3H - UL 240 VAC

Page 34: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

34 MCCB - EMB Series

Trip Curves

EMB-F3H - I2t @ 480 VAC

1 2 3 4 5 7 10 18 30 35 501

2

345

7

10

20

304050

70

100

200

300400500

700

1000

2000

10000

P

J

I²t (1

0³ A

²s)

Is (kA)

DWB400 - UL 480V10,000

1,000

2,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

I2 t (1

03 A

2 s)

EMB-F3H - UL 480 VAC

1

1 2 3 4 5 7 10 18 30 35 50

Is (kA)

Page 35: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

35MCCB - EMB Series

Trip Curves

EMB-F4H - I2t @ 240 VAC

1 2 3 4 5 7 10 20 30 40 50 70 100 1501

2

345

7

10

20

304050

70

100

200

300400500

700

1000

2000

5000

P

I²t (1

0³ A

²s)

Is (kA)

DWB600 - UL 240V5,000

2,000

1,000

400

500

700

300

200

100

70

50

40

30

20

10

7

5

4

3

2

1

1 2 3 4 5 7 10 20 30 40 50 70 100 150

I2 t (1

03 A

2 s)

Is (kA)

EMB-F4H - UL 240 VAC

Page 36: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

36 MCCB - EMB Series

Trip Curves

EMB-F4H - I2t @ 480 VAC

1 2 3 4 5 7 10 18 30 35 501

2

345

7

10

20

304050

70

100

200

300400500

700

1000

2000

10000P

I²t (1

0³ A

²s)

Is (kA)

DWB600 - UL 480V10,000

1,000

2,000

700

500

400

300

200

100

70

50

40

30

20

10

7

5

4

3

2

I2 t (1

03 A

2 s)

EMB-F4H - UL 480 VAC

1

1 2 3 4 5 7 10 18 30 35 50

Is (kA)

Page 37: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

37MCCB - EMB Series

Circuit Breakers

EMB-F1H Drilling for Fixing

Dimensions - Inch (mm)

0.984(25)

0.984(25)

2.77 (70.4)

0.984 (25)

2 x M4

2.58 (65.7)

2.91 (74)

3.04 (77.4)

3.63 (92.4)

6.25

(158

.8)

0.88

3 (2

2.4)

1.49

(38.

1)

2.62

(66.

8)

3.93

(100

)

4.01

(102

)

1.77

(45.

2)

3.06 (77.9)

Drilling for Fixing

4.88

(124

)1.37(35)

2 x M4

1.37(35)

1.37(35)

1.77

(45)

7.79

(198

.1)

0.88

6 (2

2.5)

2.38

(60.

6)

3.28

(83.

6)

5.31

(135

)

4.16 (105.8)

2.68 (68.3)

2.94 (74.8)

3.07 (78)

3.26 (83)

4.20 (106.8)

EMB-F2H

EMB-F3H

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

3,31

84,1

4,06

103,

212

,72

323

1,3835

4x M5

7,83

199

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

3,31

84,1

4,06

103,

212

,72

323

1,3835

4x M5

7,83

199

4.06

(103

.2)

12.7

2 (3

23)

1.38(35)

7.83

(199

)

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

3,31

84,1

4,06

103,

212

,72

323

1,3835

4x M5

7,83

199

2.03

(51.

6)6.

63(1

68.5

)

3.90(99.1)

4.33(109.9)

4.50(114.4)5.07

(128.8)

4.19(106.5)

3.31

(84.

1)

4x M5

Drilling for Fixing

EMB-F4H

8,19

208

12,7

232

3

3,8597,7

4,24107,7

4,43112,6

0,8922,7

2,03

51,4

4,69

119

6,59

167,

5

5,76146,4

9,17

232,

8

8,43

214

10,1

825

8,5

2,7670

2,7670

A

B

8,19

208

12,7

232

3

3,8597,7

4,24107,7

4,43112,6

0,8922,7

2,03

51,4

4,69

119

6,59

167,

5

5,76146,4

9,17

232,

8

8,43

214

10,1

825

8,5

2,7670

2,7670

A

B

8,19

208

12,7

232

3

3,8597,7

4,24107,7

4,43112,6

0,8922,7

2,03

51,4

4,69

119

6,59

167,

5

5,76146,4

9,17

232,

8

8,43

214

10,1

825

8,5

2,7670

2,7670

A

B

6.59

(16

7.5)

4.68

(119

)2.02

(51.

4)

312.

71 (3

23)

10.1

7 (2

58.5

)9.

16 (2

32.8

)

2.75 (70) 2.75 (70)

A

B

8.42

(214

)

8.18

(208

)

3.93 (100)

0.98 (25)

4.33 (110)4.51 (114.6)5.84 (148.4)

0,9825

0,50

12,7

0,89

22,7

2x0,3

59

1,9750

DETALHE A ESCALA 2 : 1

0,9825 0,

4511

,50,

8621

,8

2x 0,359

1,9750

DETALHE B ESCALA 2 : 1

0.98 (25)

0.98 (25)

1.96 (50)

1.96 (50)

DETAIL A TOESCALE 2 : 1

DETAIL B TO ESCALE 2 : 1

0.5

(12.

7)

0.45

(11.

5)

0.89

(22.

7)

0.35 (

9)

0.35 (9)

8,19

208

12,7

232

3

3,8597,7

4,24107,7

4,43112,6

0,8922,7

2,03

51,4

4,69

119

6,59

167,

5

5,76146,4

8,27210

9,17

232,

8

8,43

214

10,1

825

8,5

2,7670

2,7670

A

B

230

9,06

4 x M

5

2,7670

0,9825

0,50

12,7

0,89

22,7

2x0,3

59

1,9750

DETALHE A ESCALA 2 : 1

0,9825 0,

4511

,50,

8621

,8

2x 0,359

1,9750

DETALHE B ESCALA 2 : 1

L

J

I

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

mm [inches]Escala - 1:1 A003/05/2016

DWB800-IWB800

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

8.26 (210)

0.85

(21.

8)

Page 38: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

38 MCCB - EMB Series

Accessories

Dimensions - Inch (mm)

Drilling for FixingFrame 100

Mechanical Interlock

6.25

(158

.8)

3.93

(100

)

0.984 (25)4 x M4

3.06 (77.9)

7.20 (182.9)

4.04 (102.6)

4.13 (105)

1.06 (27.1)

Drilling for Fixing

Drilling for Fixing

7.79

(198

.1)

4.16 (105.8)

9.09 (230.9)

4.27 (108.5)

0.760 (19.3)

Frame 250

Frame 400 2 x Frame 600

4.88

(124

)

1.37 (35)

4 x M4

4.92 (125.1)

4,06

103,

212

,72

323

4,60

116,

9

3,9099,1

4,33109,9

4,50114,4

5,63142,9

0,102,5

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

4,61117

7.83

(199

)

1.38(35)

4.61(117)

4x M5

4,06

103,

212

,72

323

4,60

116,

9

3,9099,1

4,33109,9

4,50114,4

5,63142,9

0,102,5

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

4,61117

2.03

(51.

6)6.

63(1

68.5

)

0.10(2.5) 3.90

(99.1)4.33

(109.9)4.50

(114.4)

5.07(128.8)

5.63(142.9)

4,06

103,

212

,72

323

4,60

116,

9

3,9099,1

4,33109,9

4,50114,4

5,63142,9

0,102,5

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

4,61117

4.06

(103

.2)

8.79(223.3)

12.7

2(3

23)

4.60

(116

.9)

6426

142

6426

1425.66 (144)16.77 (426)6

Page 39: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

39MCCB - EMB Series

Panel Door Rotary Operating Handles

Accessories

Dimensions - Inch (mm)

Frame 100 + F1 Operator

3,02376,8

3,023

76,8

4,719119,9

[0,19]max. 5

[7,08...21,92]180...557

2,45662,4

1,73244

1,811 46

1,81146

0,1574

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A428/03/2018

MRXS-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,02376,8

3,023

76,8

4,719119,9

[0,19]max. 5

[7,08...21,92]180...557

2,45662,4

1,73244

1,811 46

1,81146

0,1574

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A428/03/2018

MRXS-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,02376,8

3,023

76,8

4,719119,9

[0,19]max. 5

[7,08...21,92]180...557

2,45662,4

1,73244

1,811 46

1,81146

0,1574

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A428/03/2018

MRXS-A-DWB160-ULS

ujei

to a

alte

raçã

o se

m a

viso

pré

vio.

As

info

rmaç

ões

cont

idas

são

val

ores

de

refe

rênc

ia.

Lo

s va

lore

s de

mos

trado

s pu

eden

ser

cam

biad

os s

in a

viso

pre

vio.

La

info

rmac

ión

és d

e re

fere

ncia

sol

amen

te.

The

valu

es s

how

n ar

e su

bjec

t to

chan

ge w

ithou

t prio

r not

ice.

The

info

rmat

ion

is fo

r ref

eren

ce o

nly.

3,02376,8

3,023

76,8

4,719119,9

[0,19]max. 5

[7,08...21,92]180...557

2,45662,4

1,73244

1,811 46

1,81146

0,1574

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A428/03/2018

MRXS-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[3.023]

[4.719][2.456]

[0.19] [1.811]

[1.8

11]

[1.732] [0.157]

[7.08...21.92]

[3.0

23]

76.8

119.962.4

max. 5 46

46

Ø44 Ø4

180...557

76.8

Frame 100 + F2 Operator

3,379

85,8

3,37985,8 5,821

147,8

4,719119,9

[0,19]max. 5

2,87473

[7,08...21,65]180...550

2,24457

2,244 57

1,73244 0,217

5,5

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A203/07/2017

MRXL-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[5.821]

[3.379]

[3.3

79]

[2.874]

[7.08...21.65]

[4.719]

[0.19]

147.8

85.8

85.8

73

180...550

119.9

max. 5

3,379

85,8

3,37985,8 5,821

147,8

4,719119,9

[0,19]max. 5

2,87473

[7,08...21,65]180...550

2,24457

2,244 57

1,73244 0,217

5,5

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A203/07/2017

MRXL-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,379

85,8

3,37985,8 5,821

147,8

4,719119,9

[0,19]max. 5

2,87473

[7,08...21,65]180...550

2,24457

2,244 57

1,73244 0,217

5,5

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A203/07/2017

MRXL-A-DWB160-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[1.732][0.217]

[2.2

44]

[2.244]

Ø44Ø5.5

57

57

Frame 250 + f2 Operator

3,379

85,8

3,37985,8 5,821

147,9

5,117130

[0,19]max. 5

2,87473

[7,48...22,24]190...565

2,244 57

2,24457

1,73244

0,2175,5

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A228/03/2018

MRXL-A-DWB250-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,379

85,8

3,37985,8 5,821

147,9

5,117130

[0,19]max. 5

2,87473

[7,48...22,24]190...565

2,244 57

2,24457

1,73244

0,2175,5

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11

mm [inches]1:1 A228/03/2018

MRXL-A-DWB250-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[1.732][0.217]

[2.2

44]

[2.244]

Ø44Ø5.5

57

57

[3.3

79]

85.8

[5.821]

[3.379]

147.9

85.8

[7.48...2.24]

[5.117]190...565

130

[0.19]max. 5

[2.874]73

Page 40: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

40 MCCB - EMB Series

Panel Door Rotary Operating Handles

Accessories

Dimensions - Inch (mm)

Frame 400 + F3 Operator

Frame 600 + F4 Operator

3,379

85,8

3,37985,8

5,821147,9

7,018178,3

[0,19]max. 5

2,87473

[ 8,66... 24,29 ] 220 ... 617

2,24457

2,244 57

1,73244

0,2175,5

L

J

I

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

mmm [inches]1:1 A228/03/2018

MRXL-A-DWB400-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,379

85,8

3,37985,8

5,821147,9

7,018178,3

[0,19]max. 5

2,87473

[ 8,66... 24,29 ] 220 ... 617

2,24457

2,244 57

1,73244

0,2175,5

L

J

I

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

mmm [inches]1:1 A228/03/2018

MRXL-A-DWB400-UL

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[1.732] [0.217]

[2.2

44]

[2.244]

Ø44 Ø5.5

57

57

[3.3

79]

[7.018]

[8.66...24.29]

[3.379]

85.8

178.3

220...167

85.8

[5.821]147.9

[0.19]max. 5

[2.874]73

3,379

85,8

3,37985,8

7,904200,8

6,232158,3

[0,19]max. 5

2,91774,1

[ 7,87 ... 22,55 ]200 ... 573

2,244 57

2,24457

1,73244 0,217

5,5

L

J

I

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

mmm [inches]1:1 A004/07/2017

MRXL-A-DWB1000

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

3,379

85,8

3,37985,8

7,904200,8

6,232158,3

[0,19]max. 5

2,91774,1

[ 7,87 ... 22,55 ]200 ... 573

2,244 57

2,24457

1,73244 0,217

5,5

L

J

I

H

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

mmm [inches]1:1 A004/07/2017

MRXL-A-DWB1000

Suj

eito

a a

ltera

ção

sem

avi

so p

révi

o. A

s in

form

açõe

s co

ntid

as s

ão v

alor

es d

e re

ferê

ncia

.

Los

valo

res

dem

ostra

dos

pued

en s

er c

ambi

ados

sin

avi

so p

revi

o. L

a in

form

ació

n és

de

refe

renc

ia s

olam

ente

.Th

e va

lues

sho

wn

are

subj

ect t

o ch

ange

with

out p

rior n

otic

e. T

he in

form

atio

n is

for r

efer

ence

onl

y.

[1.732] [0.217]

[2.2

44]

[2.244]

Ø44 Ø5.5

57

57

[3.3

79]

[3.379]

85.8

85.8

[7.904]200.8

[0.19]max. 5

[2.914]

[7.87...22.55]

[6.232]74.1

200...573

158.3

Page 41: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

41MCCB - EMB Series

55101

210

54 133

Panel Door Cutout

Panel Door Cutout

Lock-OFF Devices

4.88

(124

)

1.37(35)

2 x M4

4.16 (106)4.08 (104)

0.323

(3 x Ø8.2)

1.49 (38)

Frame 250

Frame 400

Panel Door CutoutFrame 1006.

25 (1

58.8

)

3.93

(100

)

0.984 (25)

2 x M4

3.06 (77.9) 3.68 (93.6)

0.323

(3 x Ø8.2)

2.32 (59)

Accessories

Dimensions - Inch (mm)

3,31

84,1

4,06

103,

212

,72

323

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

3,31

84,1

4,06

103,

212

,72

323

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

3,31

84,1

4,06

103,

212

,72

323

3,9099,1

4,33109,9

4,50114,4

2,03

51,6

5,07128,8

6,63

168,

5

1,3835

4x M5

7,83

199

1.38(35)

7.83

(199

)

6.63

(168

.5)12

.72

(323

)

4.06

(103

.2)

3.31

(84.

1)

2.03

(51.

6)

3.90 (99.1)

4.33 (109.9)

4.50 (114.4)

5.07 (128.8)

4.19 (106.5)

4x M5

Frame 600

55101

210

54 1332.12(54)

2.16(55)

3.97 (101)

210

5.31 (135)

Page 42: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

42 MCCB - EMB Series

Accessories

117,

54,

62

24,900,98

100,

13,

94

702,76

1,270,05

0,256,3

1,

7845

,2

0,389,7

E

D

C

B

A

1 2 3 4 5 6

1 : 1 A303/08/2012

BFR DWA160

mm [inches]

DIN Rail Base

117,

54,

62

24,900,98

100,

13,

94

702,76

1,270,05

0,256,3

1,

7845

,2

0,389,7

E

D

C

B

A

1 2 3 4 5 6

1 : 1 A303/08/2012

BFR DWA160

mm [inches]

3.94

(1

00.1

)

4.62

(117

.5)

(0.98)24.90

117,

54,

62

24,900,98

100,

13,

94

702,76

1,270,05

0,256,3

1,

7845

,2

0,389,7

E

D

C

B

A

1 2 3 4 5 6

1 : 1 A303/08/2012

BFR DWA160

mm [inches]

(1.7

8)

45.2

(0.05)1.27

(0.25)6.3

(0.38)9.7

117,

54,

62

24,900,98

100,

13,

94

702,76

1,270,05

0,256,3

1,

7845

,2

0,389,7

E

D

C

B

A

1 2 3 4 5 6

1 : 1 A303/08/2012

BFR DWA160

mm [inches]

(2.76)70

Dimensions - Inch (mm)

Page 43: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

43MCCB - EMB Series

Notes

Page 44: Molded Case Circuit Breakers MCCB - UL489 · 2020. 10. 11. · MCCB - UL489 . 2 MCCB - EMB Series Summary Introduction 03 External Accessories 12 Trip Curves 17 Installation and Connections

www.eecontrols.ca

The values shown are subject to change without prior notice. The information contained is reference values.

ED: 01 | Rev: 01 | Date: 08/2020.

LOW VOLTAGE CONTROL

Orangeville - ON - Canada

(519) 941-6845

[email protected]

For more EEC products visit our website