moshell basic command_update
TRANSCRIPT
General Moshell Commands (Applicable for RBS, RNC, MGw)
IP Address
ifconfig
Ping
if get destination inaccessable or host unreachable – most likely Transmissionif Request Timed Out – most likely Node B problemif TTL Expired in Transit – Loopback somewhere in Transmission
Unable to moshell
pglist –e (rbs)lhsh 001200 pglist –e (rnc)pgkill <handle>
check c drive on rbs should be 10 directories P2.1.6 otherwise rebuildls –l /c
Alarms
alalaaltalk
Logs
lga (Alarm log)
CV’s
cvcucvlscvmk <cv name>cvset <cv name>cvms <cv name>cv help
Cabinet Info
cabcabx
cablcabdcabxlsd
Board Status
To check the Admin and Operational status of the boards
lt pluglst plugTo Block a boardbl <proxy number of board>To Deblock a boarddeb <proxy number of board>
To restart the entire noderestartObj meoractc 0 restart
To check when the node has recovered from restartpol
lt root (to clear all proxy’s)
RBS INFO
check volumes etc
cabxlhsh 000800 volslhsh 000900 volscabd
How to tell if 3101 or 3202 or 3206
get 0
actions you can perform
note same as restartObj me
actl 0
No of calls setup (radio links)
lt radioget radio num
The number of radio links should not be 0 if calls are active or being attempted on the rbs.
From RNC
lt utrancellget utran erdl (MaxTxPowerDl)
VSWR
te –p 010600/port_0_dev_22 e all tmaCdciProcess010900011200te –p 010600 log read
or
lhsh 010600/port_0_dev_18 asc vswr
To see ASC and RET info
lt sectorlc sectorlcc sectorlst sector
To see PSU’s in PCU
lt pculcc pcustlt powerlcc powerst
get psdevice
Sometimes only 3 PSU in situ but data configured for 6.If the case you will get the following alarm PowerSupplySystem-RejectSignalFromHardware message_not_expectedit is possible that a PSU is faulty.
Volumes Full
lhsh xxxxxx volslhsh xxxxxx ls /f/dp_loadmodules (check what is loaded)lhsh xxxxxx format –f /f (format f drive)lhsh xxxxxx reload (reloads wanted progs to f drive from GPB)
RBS Capacity
lt commcontextget <proxy>number of commcontexts = number of channel elements used
lt UplinkBaseBandPoolpget <proxy>gives latest rop for rax capacity , number of calls and type and failures
If you suspect H/W capacity issue call NSS to activate traces and investigate
Spreading Factors
UL DL
Speech 12.2Kbs sf64 sf12864k/64k data sf16 sf3264K/128K data sf16 sf1664K/384K data sf16 sf8Video 64K CS sf16 sf32Streaming 57K CS sf16 sf32
Broadcast sf256Paging sf128
Measuring Aal2 Congestion
lt aal2appget <proxy>
Aal2Sp=1,Aal2Ap=1 pmExisOrigConns 0Aal2Sp=1,Aal2Ap=1 pmExisTermConns 16Aal2Sp=1,Aal2Ap=1 pmExisTransConns 0Aal2Sp=1,Aal2Ap=1 pmSuccInConnsRemote 193052Aal2Sp=1,Aal2Ap=1 pmSuccOutConnsRemote 0Aal2Sp=1,Aal2Ap=1 pmUnRecMessages 0Aal2Sp=1,Aal2Ap=1 pmUnRecParams 0Aal2Sp=1,Aal2Ap=1 pmUnSuccInConnsLocal 0Aal2Sp=1,Aal2Ap=1 pmUnSuccInConnsRemote 0Aal2Sp=1,Aal2Ap=1 pmUnSuccOutConnsLocal 0Aal2Sp=1,Aal2Ap=1 pmUnSuccOutConnsRemote 0
Check pmUnSuccInConnsLocal Number of unsuccessful attempts to allocate Common Part Sublayer, CPS, resources during establishment of incoming connections on this AP caused by Channel Identifier, CID, and/or bandwidth collision or mismatch of Call Admission Control, CAC, between peers.
Check pmUnSuccInConnsRemote Number of unsuccessful establishment of incoming connections on this AP caused by reject from beyond this node
Check pmUnSuccOutConnsLocal Number of unsuccessful attempts to allocate CPS resources during establishment of outgoing connections on this AP. Caused by rejects in CAC (Connections Admission Control). Main indicator of aal2 congestion problems , increase traffic descriptor or another E1 required.
Check pmUnSuccOutConnsRemote Number of unsuccessful establishment of outgoing connections on this AP caused by reject from remote side, reset from remote side, no reply or signalling link failure.
RAXB R2 ladder for mapping RAB’s to number of CEThere is a new ladder for RAXB R2 as shown in the table below. For 64 Kbps data twice the amount of c.e is required. This new ladder only have a small impact when dimensioning a network, as most of the data traffic is downlink and also with higher bit-rates than in uplink.
Even with the new ladder Ericsson have higher channel element efficiency than competition. Ericsson channel element implementation in the uplink is matched with competition. The channel element implementation in downlink for higher data rates is up to 50% more efficient than competition.
*) Not used in P2.1
RBS Synching up
te log read | grep –i clocknodesynch 1 after 5 minsnodesynch 2 2-3 mins after abovenodesynch 3 5 mins after aboveSite comes up 10 mins after nodesynch 3
Sector on which RAXlt prachlget prach
DownLink OK Uplink Not OK
Check ETM1 in RBS for the following
lhsh 000200 te log read
[2005-04-12 01:47:44.300] Sys_Spas_hwdrv_proc spicfunc.c:2736 INFO:SAI Egress Discard. cells (port-queue): (63-2)[2005-04-12 01:47:45.304] Sys_Spas_hwdrv_proc spicfunc.c:2736 INFO:SAI Egress Discard. cells (port-queue): (63-2)[2005-04-12 01:47:46.308] Sys_Spas_hwdrv_proc spicfunc.c:2736 INFO:SAI Egress Discard. cells (port-queue): (63-2)
Also check the ETM1 in the RXI for the above ,also check if any other RBS on this ETM1 are experiencing the same problem.
eglhsh 001600 te log read
ServiceRAXB
R1 (UL)RAXB
R2 (UL)
TXB R1 (TXB board in the DL is not changed
for RBS R2)
12,2 kbps speech 1 1 1
32 Kbps CS or PS 1 2 1
64 Kbps CS or PS 2 4 2
128 Kbps CS or PS * * 4
384 Kbps CS or PS * * 8
Format the flash f drive and restart the boardlhsh xxyyzz format –f /flhsh xxyyzz reload
RNC INFO
RNC Module Redundant
1 001400 (MS) Slot14 Slot152 011300 (ES1) Slot13 Slot163 011400 (ES1) Slot14 Slot164 011500 (ES1) Slot15 Slot165 021300 (ES2) Slot13 Slot166 021400 (ES2) Slot14 Slot167 021500 (ES2) Slot15 Slot168 001600 (MS) Slot16 Slot159 011200 (ES1) Slot12 Slot1610 011700 (ES1) Slot17 Slot1611 021200 (ES2) Slot12 Slot1612 021700 (ES2) Slot17 Slot16
To block all cells in RNC to force people to roam
before blocking check cells already blockedlt ^utrancellst utrancell dis (make a note of these)bl utrancell
When problem fixed deblock all cellsdeb ^utrancellbl <utrancells that were blocked b4)
Common RBS Problems
Nbap Common down – block and deblock proxyslt nbap|^utranclc <utrancell>lst <utrancell>lst <iublink id>
Nbap Dedicated down – Restart ETB in rbsCell down – block deblock proxy’sRach , Fach, Pch – block deblock proxy’s
To block a sectorbl <proxy of sector to be blocked>deb <proxy of sector to be deblocked>
To block entire RBSlbl <utrancell>
To deblock entire RBSldeb <utrancell>
CV's
cvcucvlscvms egralyn correct maxtxpowerdlcv cucv lscv help
Utrancell state availability
strstr1str2st utrancell dis|\(lo)
To find ip address
ifconfig
Restart logsLgo – to print out llogllog -lllog -l 3all llog
Board Info
cabxcablcabxlsd
Signal Links in MGW
lt mtp3blst mtp3bget <proxy>acl <proxy>acc <proxy>
Call Disconnected by UE and not Utran
If the UE disconnects the call with interworking unspecified , look in the NAS setup message sent from the CN to the UE. this can help to located the problem in the core. Especially low layer compatability component of Setup message.If possible compare to a good call.
Command from RNC or GNNCC
java commands LOAD :/opt/ericsson/cominf/Netscape_TRE_131_09
Starting Commands : ehassha@ri3guas1> cd ./moshell ehassha@ri3guas1>./moshell 3rj01 ( 3rj01- RNC)
lt utrancell|nbap|aal|etm : Load Managed Object
lt all : Load all Mo( managed object )
cab : (cabinet )
cabx : (including boards)
lt plug : ( load MO's)
lst plug : ( Monitor per site including board )
str : ( status of RNC Locked and unlocked cell )
strt : status RNC with ETM Bords( ES-?-?-? ima 23 )
alt : (alarm to monitor sites )
alk : acknowledge( Warning/major or minor alarms) lgd : alarm log with downtime
llog : Check restarted data
lgaes : alarm log all
lgs :display the system log for the whole period stored in system log (can be several months)
lgasmi 30 :display the last 30 days of the alarm and system logs, merge them and show them in reverse chronological order.lgaevs 5h :display the last 5 hours of the alarm/event/availability/system logs.
lgac 30m :display the last 30 minutes of the alarm log and print the output into a csv file.
bl : ( Locked cell )
deb : (unlocked cell)
pmr : will show statistics
tg (Site id ) : Check Cell error code, cellbarred, actor info.
get radiolink : User &Traffic
get rbslocalcell:- : cell id / If the site dont comes up after intergration check the below.
ueregprint sum : To view total users ( i.e ueregprint sum $ 380 UEs registered. )
.lt iub : on both nodes .lk IubLink=Iub_GRYxxx : in RNC .lk iub=<iub>/lst iub : in RBS AAL2 Addresses :-
.get aal2routingcase=<rbsroutingcase: in RNC .get aal2sp=1966101000200046 : in RBS
VCI values :-
. get aal2path xxxx : Nbap number only . lst bxxx : without Nbap comman ID . get bxxxxca : with Nbap command ID ( Then will see the IUB Name ) localCellId :- . lst cell : in RBS . get cell=gnj357 localcell : in RNC
========================================================================= Transmission :-
lacc atmport=<port>,vpltp=<vp>,vpctp=1,vclXX eteloopback : VCL 32 / 33 for signalling
get cell= local : RNC
get utrancell=gryXXX local : in RNC
get sync : synchonization
acc 0 restrart : restart Node B
acc 010600 restart : restart AIUB sector 1
acc 010900 restart : restart AIUB sector 2
acc 011200 restart : restart AIUB sector 3
lhsh 001200 ps port * (3206) : VSWR ( Choose the TMA port )exp:lhsh 001200/port_1_dev_12 asc vswr : for available for 3206 cabinet only
=====================================================================
lhsh 010600 ps port * (3202)choose AIUB : for available for 3202 cabinet onlyexp:lhsh 010600/port_0_dev_18 asc vswr : for available for 3202 cabinet
lhsh 010900 ps port * : for available for 3202 cabinet exp:lhsh 010900/port_0_dev_20 asc vswr : for available for 3202 cabinet
lhsh 011200 ps port *exp:lhsh 011200/port_0_dev_22 asc vswr : for available for 3202 cabinet exp:
======================================================================
At NodeB : 10:19 11/02/2007 :
lt ret : Calibrate RET
lst ret : List RET device
pr retdevice : get RET proxy
get ret electrical : See overall value
set (proxy) electricalAntennaTilt XX : Change tilting value
get jumper : For jumper Attenuation
get feeder : For Feeder Attenuation
get feeder Attenuation : For Feeder Attenuation ( All Sector )
actl : Action list =Proxy = 1403 ( Choice either one frm 1401/1402/1403 )
actc : Action call =Proxy = 1403 ( Choice either one frm 1401/1402/1403 ) actc 1403 forceCalibration : ( Choice either one frm 1401/1402/1403 )
get 0 : RBS Type
cvls : CV's Data
get XXX (sector proxy) : Cell id
lget utrancell cid XXXX : To check cell id at RNC
st plug : list MO's ( Managed Object )
dif : Compare two Mos
===========================================================================================Must Perform at RNC:-
lget utrancell=(Site Num) utrancellref : To find neighbouring cell 3G
lget utrancell=(Site Num) gsmcellref : To find neighbouring cell 2G
lpr utrancell=(Site Num) utranrelation : To find all relation Utrancell & GSM
lt utranc : To Load Utrancell Scrambling codes
lget utran primarysc : To find power and scarmbling codes.
lget (Site Name) primarys : To find sector scrambling codes for site.
lget utran primarysc (Scrambling code) : To find same scrambling which is using to another site.
get Aal2sp : To check the Aal2ea which is connected to RNC.
lget Aal2sp : With operating state (NODE-B)
lget (exp-Aal2sp:966101000200046) : To check the Aal2Ap=bXXX which site is connected under this Nbap in RNC.
get aal2pathvcctp=bXXXX : To get path port from RNC
lst bxxx(Nbap) : To check operating state with proxy.
get bxxxca(Proxy) : To check Nbap Enable or Disable in RNC and will know whether the site is correct or not..
get sector lat/lon : To get sector's langlitude/longlitude.
pr iub : To get RBS ID and get proxy/ NodeBFunction=1,Iub=GRYXXX
pr retdevice : Ret device
get <proxy> : Operating State
get config : Overall Configuration In ( Node B & RNC )
=======================================================================================================
CVMS : To create New CV via moshell ( NODE B ) cvrm (cv-name) : Remove CV name
cvms (cvname) : Create CV name
cvmk (cvName) : to create cv
cvset (cvname) : To set the Set Startable
cvls : All Cv's Including Basic and Upgrade package with created date.
cvcu : CV detail and Running CV
=======================================================================================================
st atmport : To check E1 state in Node B
lst plug 0 : To check locked board in node
Acc 000900 restart : To restart / reload board In all nodes
Acc 001400 reload : To restart / reload board In all nodes
pmxh utrancell downtime : Downtime counters will be displayed side by side
pmr -m 5 : will show statistics for the last 5 hours
lt vcl : Lt vcl e.g pmReceivedAtmCells/pmTransmittedAtmCells of VclTp
pget vcl : error :-pmReceivedAtmCells/pmTransmittedAtmCells of VclTp
get all ingressAtmPcr : View only one attribute of all AtmTrafficDescriptors: Attribute: ingressAtmPcr
get all in.*P : to view filter output
st all dis : View all disable Mo's
================================================================================================================
CHECK E-1
RNC
lst xxx : (gryxxx site name )
get proxy : ( proxy for nbapcommon/dediccated )e.g b1102ca
lst b1102 : ( print all atm layer com -note the aal2 )
Lpget (ATM boards) : ( to check performance TX/RX Error)
get xxx : (proxy ATM PORT)
pr etm : to print AAL path file.
lcc xxx : (proxy )
Lst (copy paste subrack) : ATM port performance Error.
st xxx : (proxy)
LPget xxx : (proxy to get performance error E1)