Page 1: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

1 March 31, 2008

Motor Protection Relays

Page 2: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

2 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 3: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

3 March 31, 2008

Solcon Products

MPS-3000-P/C Motor Protection/Controller System

MPS-6 Advanced Motor Protection Relay

MPR-6 Motor Protection Relay

MPC-6 Motor Protection/Controller Relay

TPR-6/14 Temperature Protection Relay

MIP-6 Motor Insulation Protection Unit

Page 4: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

4 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 5: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

5 March 31, 2008

Motor Protection Relay

Protection Functions

Page 6: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

6 March 31, 2008

Protection Functions

Current based protection:

Too Many Starts Level 1 (66)

Undercurrent Level 1 (37)

Undercurrent Level 2 (37)

Load Increase - Alarm (51L)

Over Current Level 1 – Jam (51R)

Over Current Level 2 – Short (50)

Thermal Capacity Level 1 (49/51)

Thermal Capacity Level 2 (49/51)

MPS/C 3000

MPS 6

MPC 6

MPR 6

Current Imbalance Level 1 (46)

Current Imbalance Level 2 (46)

(Positive / Negative Sequence)

Ground Fault Level during starting (50G)

Ground Fault Level 1 (50G)

Ground Fault Level 2 (50N)

Max. Start Time (48)

Page 7: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

7 March 31, 2008

Voltage based protection:

Under-voltage (27)

Over-voltage Level 1 (59)

Over-voltage Level 2 (59)

Phase loss (47)

Phase sequence (47)

MPS/C 3000

MPS 6

MPC 6

MPR 6

Protection Functions cont.

Page 8: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

8 March 31, 2008

Under Current (37) Level 1/2

MPS/C 3000

MPS 6

MPC 6

MPR 6

2 1

Tripping Zone

t

I/In

Page 9: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

9 March 31, 2008

Time Over Current (51) Level 1/2

MPS/C 3000

MPS 6

MPC 6

MPR 6

2 1

Tripping Zone

t

I/In

Page 10: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

10 March 31, 2008

Inst. Over Current (50) Level 1/2

MPS/C 3000

MPS 6

MPC 6

MPR 6

2 1

Tripping Zone

t

I/In

Page 11: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

11 March 31, 2008

Current unbalance protection(46)

Current symmetrical component

I1 (positive sequence current) = 1/3(Ia + αIb + α2Ic)

I2 (negative sequence current) = 1/3(Ia + α2Ib + αIc)

I0 (zero sequence current) = 1/3(Ia + Ib + Ic)

α = ej120

Positive sequence Negative sequence Zero sequence

MPS/C 3000

MPS 6

MPC 6

MPR 6

Page 12: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

12 March 31, 2008

Current unbalance protection(46) cont.

Actual Unbalance (%)

100908070605040302010

Par

amet

er:

U/B

LV

L 2

Max

Tim

e

(Sec

)

1

2

3

4

5

10

120

1000

80

60

40

20

Operating Range

% Unbalance = I2/I1 X 1000

Page 13: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

13 March 31, 2008

Thermal/Overload Protection (49)

Thermal Capacity – Hot/Cold Ratio

Thermal Capacity – Equivalent to Max. allowed operating motor temperature

Based on Standard “American” Curve

Hot/Cold Ratio – Thermal Capacity Hot/Thermal Capacity Cold

Hot/Cold Ratio - Locked Rotor Time Hot/ Locked Rotor Time Cold

Hot/Cold Ratio = Available Thermal Capacity

1 – Hot/Cold Ratio = Thermal Capacity used

RTD Biased Thermal Protection

MPS/C 3000

MPS 6

MPC 6

MPR 6

Page 14: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

14 March 31, 2008

Thermal/Overload Protection (49) Cont.

Thermal Over Load Curve Multiplier = 6

1.0

10.0

100.0

1000.0

10000.0

100000.0

I/In

t

Page 15: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

15 March 31, 2008

Thermal/Overload Protection (49) Cont.

MPS/C 3000

MPS 6

MPC 6

MPR 6

Page 16: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

16 March 31, 2008

Power Based Protection

Under Power Level 1 (32L)

Under Power Level 2 (32L)

Low Power Factor (55)

MPS/C 3000

MPS 6

MPC 6

MPR 6

Page 17: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

17 March 31, 2008

Temperature Based Protection RTD Based

High Temp. Level 1, sensors 1-10 (49R)

High Temp. Level 2, sensors 1-10 (49R)

3 RTD’s for MPS-6 & MPR-6

1 RTD for MPC-6

MPS/C 3000

MPS 6

MPC 6

MPR 6

Page 18: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

18 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 19: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

19 March 31, 2008

Motor Protection Relay

Tripping & Alarm Options

Page 20: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

20 March 31, 2008

Tripping & Alarm Options Principals

Each protection can be Enabled / Disabled for:

Alarm

Trip

Auto Reset

Panel Reset

Remote Reset

Relay A

Relay B

Level 1 & 2 can be used for Alarm & Trip or both for trip

Page 21: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

21 March 31, 2008

Tripping & Alarm Options Table

No. Fault Trip Alarm Auto Reset

Panel Reset

Remote Reset

Output A Output B Active During

ANSI Code

1 Max Start Time (-) (+) (-) (+) (+) (-) (-) Start 48

2 Too Many Starts (-) (-) (-) (+) (+) (-) (-) Start 66

3 U/C Level 1 (-) (+) (-) (+) (+) (-) (-) Run 37

4 U/C Level 2 (-) (-) (-) (+) (+) (-) (-) Run 37

5 Load Increased (-) (+) (-) (+) (+) (-) (-) Run 51L

6 O/C Level 1- Jam (+) (+) (-) (+) (+) (-) (-) Run 51R

7 O/C Level 2- Short (+) (+) (-) (+) (+) (-) (-) Always 50

8 Thermal Level 1 (-) (+) (-) (+) (+) (-) (-) Always 49/51

9 Thermal Level 2 (+) (+) (-) (+) (+) (-) (-) Always 49/51

10 Unbalance Level 1 (-) (+) (-) (+) (+) (-) (-) Always 46

11 Unbalance Level 2 (+) (+) (-) (+) (+) (-) (-) Always 46

12 Undervoltage (-) (+) (-) (+) (+) (-) (-) Run+Start 27

13 O/V Level 1 (-) (+) (-) (+) (+) (-) (-) Run+Start 59

14 O/V Level 2 (+) (+) (-) (+) (+) (-) (-) Run+Start 59

15 Phase Loss (+) (+) (-) (+) (+) (-) (-) Always 47

16 Phase Sequence (+) (+) (+) (+) (+) (-) (-) Always 47

17 GND Fault Level 1 (-) (+) (-) (+) (+) (-) (-) Always 50G

18 GND Fault Level 2 (+) (+) (-) (-) (-) (-) (-) Always 50N

19 Comm. Port Failed (-) (-) (+) (+) (+) (-) (-) Always 3

20 Internal Failure (-) (+) (-) (-) (-) (-) (-) Always 3

21 Control Cir. open (-) (-) (-) (+) (+) (-) (-) Beginning of Start

74

22 Welded Contactor (-) (-) (-) (+) (+) (-) (-) Beginning of Stop

74

23 External Fault 1 (-) (-) (-) (+) (+) (-) (-) Always 86 or 94

24 External Fault 2 (-) (-) (-) (+) (+) (-) (-) Always 86 or 94

25 External Fault 3 (-) (-) (-) (+) (+) (-) (-) Always 86 or 94

26 RTD 1 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

27 RTD 1 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

No. Fault Trip Alarm Auto Reset

Panel Reset

Remote Reset

Output A Output B Active During

ANSI Code

1 Max Start Time (-) (+) (-) (+) (+) (-) (-) Start 48

2 Too Many Starts (-) (-) (-) (+) (+) (-) (-) Start 66

In this table, (+) stands for "Enabled", (-) for "Disabled".

Page 22: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

22 March 31, 2008

Tripping & Alarm Options Table Cont.

No. Fault Trip Alarm Auto Reset

Panel Reset

Remote Reset

Output A Output B Active During

ANSI Code

28 RTD 2 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

29 RTD 2 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

30 RTD 3 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

31 RTD 3 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

32 RTD 4 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

33 RTD 4 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

34 RTD 5 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

35 RTD 5 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

36 RTD 6 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

37 RTD 6 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

38 RTD 7 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

39 RTD 7 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

40 RTD 8 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

41 RTD 8 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

42 RTD 9 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

43 RTD 9 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

44 RTD 10 Level 1 (-) (-) (-) (+) (+) (-) (-) Always 49R

45 RTD 10 Level 2 (-) (-) (-) (+) (+) (-) (-) Always 49R

46 Under Pwr Level 1 (-) (-) (-) (+) (+) (-) (-) Run 32L

47 Under Pwr Level 2 (-) (-) (-) (+) (+) (-) (-) Run 32L

48 Low Power Factor (-) (-) (-) (+) (+) (-) (-) Run 55

49 Analog Input # 1 (-) (-) (-) (+) (+) (-) (-) Always

50 Analog Input # 2 (-) (-) (-) (+) (+) (-) (-) Always

51 Analog Input # 3 (-) (-) (-) (+) (+) (-) (-) Always

52 Analog Input # 4 (-) (-) (-) (+) (+) (-) (-) Always

In this table, (+) stands for "Enabled", (-) for "Disabled".

Page 23: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

23 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 24: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

24 March 31, 2008

MPS as a Controller

Page 25: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

25 March 31, 2008

MPS 3000-C Inputs/Control Functions

Start – Local/Remote (Momentary or Maintained)

Stop

Communication Remote Start/Stop

Interlock (NO or NC)

Contactor Control

Running Indication (Motor Contactor Status)

U/V Start Prevent- P/C

U/V Restart (Mains or Control U/V)

Trip @ No Volt –P/C

Start Inhibit (Fault , Excessive No. of Starts-P/C)

4 Programmable Inputs

Isolator Switch Input

Page 26: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

26 March 31, 2008

MPS 3000-P Wiring Diagram

Page 27: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

27 March 31, 2008

MPS 3000-C Wiring Diagram

Page 28: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

28 March 31, 2008

MPS 3000-C Inputs/Control Functions

Local Start-A………………………….1&24

Close the contact to operate contactor A. Maintained or Momentary contacts can be used.

Open contact overrides any other inputs and force stop condition.

Local Start-B………………………….2&25

Close the contact to operate contactor B. Maintained or Momentary contacts can be used.

Used for low speed of two speed motor and for reversing applications.

Leave open if not in use.

Page 29: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

29 March 31, 2008

MPS 3000-C Inputs/Control Functions Cont.

Page 30: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

30 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 31: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

31 March 31, 2008

MPS 3000

Special Features

Page 32: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

32 March 31, 2008

MPS 3000-P/C Special Features

Communication

RS 485, half duplex, MODBUS Protocol, baud rate 1200-19200 bits/sec. enables parameter change, supervision and remote resetting.

20 user-selectable parameters grouping of Actual Data.

Other protocols (plug-in board) – consult factory.

Emergency Start (key operated function)

Canceling the Thermal Capacity and Too Many Starts limits to allow emergency restart after fault.

Real Time Clock

Time stamp for each fault – Date, Hour and Minute.

Page 33: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

33 March 31, 2008

MPS 3000-P/C Special Features Cont.

Fault Simulation

Simulation of voltage, currents and temperature faults enables relay

testing.

This simulation Program allows testing and self-learning of the

MPS 3000.

The MPS -3000/C also incorporates two additional protection

functions:

Control Circuit Open (74)

Welded Contactor (74)

Page 34: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

34 March 31, 2008

MPS 3000-P/C Analog I/O’s

4 Analog Inputs Each Configurable to:

Analog In 1 Type 4…20mA Selects between 0...20mA (or 0...1mA

by special order) and 4...20mA analog input type.

Analog In 1 Level. Above 50%Fault Level. The fault occurs when

input is Above (or Below, if set so) Analog In 1 Level for more than

Analog In 1 Delay. Range: Below 0...100%, Above 1..100%.

Analog In 1 Delay10 Sec. Time Delay for the Analog Input 1 fault.

Range: 0..250 Sec.

Page 35: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

35 March 31, 2008

MPS 3000-P/C Analog I/O’s Cont.

4 Analog Outputs Each Configurable to:

Analog Out 1-4 Par. I,V,P,T…. .

Range: Actual All Measured Values..

Analog Out 1-4 Min. 0 % of Selected Value for zero (0 or 4mA)

output.

Range: 0...200 (Units change with parameter).

Analog Out 1-4 Max. 200 % of Selected Value for maximum

(20mA, or 1mA by special order) output.

Range: 0...250 (Units change with parameter).

Page 36: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

36 March 31, 2008

MPS 3000-P/C Actual Data

Measured values (True R.M.S.@ .5msec)

Three phase voltage phase to phase

Three phase voltage phase to neutral

Current each phase

Ground current

Temperature / Resistance each sensor

Energy with programmable pulse output

Power, Reactive power, Power factor

Min & Max RMS 3 phase value of Voltage, Current and Frequency

Page 37: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

37 March 31, 2008

MPS 3000-P/C Actual Data Cont.

Calculated data

Motor current in % of FLC

Motor Equivalent current

Imbalanced current

Thermal capacity

Time to trip

Time to start (after fault)

Page 38: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

38 March 31, 2008

MPS 3000-P/C Actual Data Cont.

Statistical data

Total run time

Total number of starts

Total number of trips

Last start time period

Last start current peak

Energy

Page 39: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

39 March 31, 2008

MPS 3000-P/C Installed in MV Cabinet If the MPS uses separate (not the internal soft starter) CTs and PTs (current and voltage transformers), then set all MPS parameters according to the instruction manual.

If, however the MPS uses the Medium Voltage starter Internal CTs and PTs, then few parameters settings must be done as explained here.

Inside the soft starter, there is an electronic Potential Transformer. It’s “primary” rated voltage is equal to the starter rated voltage. It’s “secondary” rated voltage is 120VAC.

Inside the soft starter, special CTs are used. Their primary rated current equals to the starter rated current. Their secondary rated current is 2A. The secondary current is connected to the MPS 5A input.

In the SYSTEM PARAMETER setting page, please set:

LINE VOLTS= Actual rated line voltage (should be equal or lower than starter rated voltage).

VT PRIMARY = Starter rated voltage (the Electronic Potential Transformer is calibrated tothe starter rated voltage).

VT SECONDARY = 120 (the EPT “secondary” rated voltage).

Page 40: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

40 March 31, 2008

MOTOR FLC = Actual Motor Name Plate (Rated) current (should be equal or

lower than starter rated current).

CT PRIMARY = 2.5 * Starter Rated Current.

GND CT PRIMARY = same as CT PRIMARY setting.

Explanation of CT PRIMARY: If The rated starter current is - for example -

250A, it's CTs (that are used also for the MPS) are 250 / 2A.

Please note that CTs secondary current is 2A, not 5A. The MPS current input used

is 5A.

When 250A flows, the MPS gets only 2A instead 5A and will calculate 2 / 5 *250 =

100A.

Therefore we have to set the CT Primary to 250*(5/2)=625, which with 2A will read

exactly 250A as required.

Please note that in the MPS3000, you have to store each parameter separately (while

in the starter you store all parameters of a page together

MPS 3000-P/C Installed in MV Cabinet cont.

Page 41: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

41 March 31, 2008

MPS 3000-P/C Installed in MV Cabinet cont.

Page 42: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

42 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 43: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

43 March 31, 2008

MPS 3000

HMI Settings

Page 44: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

44 March 31, 2008

MPS 3000-P/C HMI Settings

DATA PAGE MEASURED

-*****- PAGE 9

CALCULATED

-*****- PAGE 10

LOGICAL INPUTS

CONTACT STATUS PAGE 11

STATISTICAL DATA

-*****- PAGE 12

FAULT DATA

-*****- PAGE 13

TEST/MAINTENANCE

***OPTIONS*** PAGE 14

? PAGE 8 COMMUNICATION

****SETTINGS****

PAGE 5 TEMPERATURE

****SETTINGS****

PAGE 7 TRIPPING / ALARM

****SETTINGS****

SET PAGE

PAGE 6 ANALOG I/O

****SETTINGS****

SYSTEM PARAMETER

****SETTINGS**** PAGE 0

VOLTAGE

****SETTINGS**** PAGE 1

CURRENT

****SETTINGS**** PAGE 2

OVERLOAD

****SETTINGS**** PAGE 3

POWER

****SETTINGS**** PAGE 4

Page 45: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

45 March 31, 2008

OUTPUT DELAY

0 SEC

CONFIG. INPUT A

AUTORIZE KEY

CONFIG. INPUT B

EXT. FAULT 1

SYSTEM PARAMETER

****SETTINGS****

LINE VOLTAGE

415 V

VT PRIMARY

VT NOT CONNECTED

VT SECONDARY

VT NOT CONNECTED

MOTOR FLC

100 AMP.

CT PRIMARY

100 AMP.

GND CT PRIMARY

100 AMP.

GND ALARM

10 SEC.

G/F ALARM DELAY

10 SEC.

GND TRIP

10% OF FLC

G/F TRIP DELAY

0.5 SEC.

CURRENT INHIBIT

OFF

START/STP SIGNAL

MOMENTARY

STARTING METHOD

DIRECT ON LINE

CONFIG. OUTPUT D

TRIP

VOLTAGE

****SETTINGS****

U/V SETTING

80% OF Vn

U/V DELAY

5.0 SEC.

U/V STRT PREVENT

OFF

O/V LEVEL1

115% OF Vn

O/V LEVEL2

120% OF Vn

O/V LEVEL 2 DELAY

1 SEC. TRANSITION TIME

10 mSEC.

START TO DELTA AT

GONFIG. OUTPUT A

OVERLOAD TRIP

OUTPUT DELAY

0 SEC.

CONFIG. OUTPUT B

GND FAULT TRIP

OUTPUT DELAY

O SEC.

CONFIG. OUTPUT C

ALARM-FAIL SAFE

OUTPUT DELAY

0 SEC

LINE REQUENCY

60Hz

MAX TIME IN STAR

CONFIG. INPUT C

EXT. FAULT 2

CONFIG. INPUT D

REMOTE RESET

PROTECTION ONLY

YES

?

MPS 3000-P/C HMI Data/Programming Pages PAGE 0 PAGE 1

Page 46: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

46 March 31, 2008

CURRENT

****SETTINGS****

MAX. START TIME

10 SEC.

NUMBER OF START

10

STARTS PERIOD

30 MIN.

START INHIBIT

15 MIN.

U/C LEVEL 1

50% OF FLC

U/C LVL 1 DELAY

2 SEC.

U/C LEVEL 2

40% OF FLC

U/C LVL 2 DELAY

5 SEC.

LOAD INCREASE AL

120% OF FLC

O/C LEVEL 1-JAM

400% OF FLC

O/C LVL 1 DELAY

2.0 SEC.

PAGE 2

O/C LVL 2 - SHORT

800 % OF FLC

O/C LVL 2 DELAY

0.5 SEC.

UNBALANCE LVL2

15% OF FLC

U/B LVL 2 MAX T

30 SEC

OVERLOAD

***SETTING***

STP COOL T CONST

30 MIN.

HOT/COLD RATIO

50%

RUN COOL T CONST

10 MIN

RTD BIAS.

OFF

RTD BIAS MINIMUM

40 C

UNBALANCE K FCTR

5

THERMAL LEVEL 1

80% OF CAPACITY.

STALL TIME FCTR

50%

OVERLOAD PICKUP

105% OF FLC.

RTD BIAS MIDDLE

130 C

RTD BIAS MAXIMUM

155 C

PAGE 3

?

Page 47: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

47 March 31, 2008

TEMPERATURE

****SETTINGS****

RTD TYPE

PLATINUM 100 OHM

SENSOR 7-10 TYPE

RTD

T1 LEVEL 1

120 EC

T1 LEVEL 2

140 EC

Same settings

for RTD 2..6

T7 LEVEL 1

80 EC

T7 LEVEL 2

100 EC

Same Settings for

RTD 8 & 9

T10 LEVEL 1

80 EC

T10 LEVEL 2

100 EC

Note: If Sensor 7-10 are

thermistors, then units

of 7-10 are KΩ

POWER

****SETTINGS****

RATED PF AT FLC

0.88 LAG

UNDER PWR LVL1

45%

U/P LVL 1 DELAY

30 SEC.

UNDE PWR LVL 2

25%

U/P LVL 2 DELAY

30SEC.

LOW POWER FACTOR

0.58 LAG

LOW PF DELAY

30 SEC.

KWH PER PULSE

OFF

?

PAGE 4 PAGE 5

Page 48: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

48 March 31, 2008

ANALOG I/O

*** SETTINGS***

ANALOG OUT TYPE

4..20mA

ANALOG OUT 1 PAR.

AVERAGE CURRENT

ANALOG OUT 1 MIN.

0% OF FLC

ANALOG OUT 1 MAX.

200% OF FLC

ANALOG OUT 2 PAR.

AVG. LINE VOLTS

ANALOG OUT 2 MIN.

0% OF Vn

ANALOG OUT 2 MAX.

200% OF Vn

ANALOG OUT 3 PAR.

THERMAL CAPACITY

ANALOG OUT 3 MIN.

0% OF CAPACITY

ANALOG OUT 3 MAX.

200% OF CAPACITY

ANALOG OUT 4 MIN.

0° C

ANALOG OUT 4 MAX.

200° C

ANALOG IN 1 TYPE

4..20mA

ANALOG IN 1 LEVEL

ABOVE 50%

ANALOG IN 1 DELAY

10 SEC.

Same settings for

Analog in 2,3 & 4

?

PAGE 6

Page 49: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

49 March 31, 2008

COMMUNICATION

****SETTINGS****

MOTOR NUMBER

0

BAUD RATE

19200

ADDRESS NUMBER

248

S.LINK SAVE LOCK

LOCKED.

ANALOG INPUT # 4

REMOT RST: ENABL

ANALOG INPUT # 4

PANEL RST: ENABL

ANALOG INPUT # 4

AUTO RST: DSABL

VL12 VL23 VL31

400 400 400 V

I1 I2 I3

100 101 100 A

GROUND CURRENT

0 AMP.

FREQUENCY

50.0Hz

POWER

563.2 KW

REACTIVE POWER

601.3 KVAR

POWER FACTOR

0.88

T1 T2 T3

105 104 105 °C

T4 T5 T6

105 104 105 °C

T7 T8 T9

80 85 ???°C

T10

??? °C

ANALOG INPUT # 1

20%

ANALOG INPUT # 2

20%

ANALOG INPUT # 3

20%

ANALOG INPUT # 4

20%

Note: If Sensor 7-10 are

Thermistors, then units

For T7-T10 are KΩ

VP1 VP2 VP3

230 230 230 V

MEASURED DATA

-***-

TRIPPING / ALARM

****OPTIONS****

MAX START TIME

TRIP: DISABLE

MAX START TIME

ALARM: ENABLE

MAX START TIME

AUTO RST: DSABL

MAX START TIME

PANEL RST: ENABL

MAX START TIME

REMOT RST: ENABL

Similar settings for next

50 fault protections

ANALOG INPUT # 4

TRIP: DISABLE

ANALOG INPUT # 4

ALARM: DISABLE

?

PAGE 7 PAGE 8 PAGE 9

Page 50: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

50 March 31, 2008

CALCULATED DATA

-****-

MOTOR LOAD CURR.

96% OF FLC

EQUIVALENT CURR.

97% OF FLC

UNBALANCE CURR.

5%

THERMAL CAPACITY

48% OF CAPACITY

TIME TO TRIP O/L

NO TRIP EXPECTED

TIME TO START

0 SEC.

LOGICAL INPUTS -

CONTACT STATUS

DISCRETE INPUT A

CONTACT OPEN

DISCRETE INPUT B

CONTACT OPEN

DISCRETE INPUT C

CONTACT OPEN

DISCRETE INPUT D

CONTACT OPEN

Above fields are visible

only if protection only is

set to Yes. If it is set to

No, then status of motor,

as well as status of all

10 inputs of MPS 3000-C

can be displayed

STATISTICAL DATA

-****-

TOTAL RUN TIME

9857 HOURS

TOTAL # OF START

410

TOTAL # OF TRIPS

7

LAST STRT PERIOD

9.8 SEC.

LAST START MAX I

760 AMP

TOTAL ENERGY

457,235 KWH

MINIMUM VOLTAGE

395 VOLT

MAXIMUM VOLTAGE

404 VOLT

MINIMUM CURRENT

73 AMP

MAXIMUM CURRENT

86 AMP

MIN. FREQUENCY

49.9 Hz

MAX. FREQUENCY

50.1 Hz

FAULT DATA

-****-

LAST RIEP

EXTERNAL FAULT 1

LAST ALARM

MAX START TIME

TRIP I1, I2, I3

431 435 432 A

TRIP GND CURRENT

0 AMP.

TRIP VP1, VP2, VP3

230 230 230 V

LAST 10 TRIPS:

EXTERNAL FAULT 1

08:32 08/05/02

T1 LEVEL 2

13:33 06/13/02

O/C LVL 2-SHORT

11:26 03/21/02

Similar messages of

previous 7 trips

?

PAGE 8 PAGE 9 PAGE 10 PAGE 11

Page 51: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

51 March 31, 2008

TEST/MAINTENANCE

****OPTIONS****

RUN SELF TEST ?

PUSH (A.UP) TO RUN

PROGRAM VERSION

MPC090796MODBUS

STORE ENABLE

DEFAULT SETTINGS

RESET OG STORE

STATISTICAL DATA

?

PAGE 13

Page 52: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

52 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 53: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

53 March 31, 2008

MPS 6

Motor Protection Relay

Page 54: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

54 March 31, 2008

MPS 6 Motor Protection & Control

Monitoring 3-phase currents, 1-phase low voltage and up to 3 temperature inputs

Page 55: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

55 March 31, 2008

MPS 6 Motor Protection & Control

The MPS 6 is ideal for:

Large low voltage motors

Applications where full protection and advanced warning is crucial, such as in the process and chemical industries.

Monitoring three phase currents,

voltages and up to 3 temperature inputs it provides the most comprehensive motor protection package.

Page 56: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

56 March 31, 2008

MPS 6 Motor Protection & Control

Page 57: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

57 March 31, 2008

MPS 6 Motor Protection Functions Current based protection:

Too Many Starts Level 1 (66)

Undercurrent Level 1 (37)

Undercurrent Level 2 (37)

Load Increase - Alarm (51L)

Over Current Level 1 – Jam (51R)

Over Current Level 2 – Short (50)

Thermal Capacity Level 1 (49/51)

Thermal Capacity Level 2 (49/51)

Current Imbalance Level 1 (46)

Current Imbalance Level 2 (46)

(Positive / Negative Sequence)

Ground Fault Level during starting (50G)

Ground Fault Level 1 (50G)

Ground Fault Level 2 (50N)

Max. Start Time (48)

Page 58: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

58 March 31, 2008

MPS 6 Motor Protection Functions Cont.

Voltage based protection:

Under voltage (27)

Over voltage Level 1 (57)

Over voltage Level 2 (57)

Phase Loss (47)

Page 59: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

59 March 31, 2008

MPS 6 Motor Control Functions

Start (Momentary or Maintained)

Stop (Momentary or Maintained)

Communication Remote Start/Stop

Interlock (NO or NC)

Contactors Control

Running Indication (Motor Contactor Status)

U/V Start Prevent- P/C

Trip @ No Volt –P/C

U/V Restart (Mains or Control U/V)

Start Inhibit (Fault , Excessive No. of Starts-P/C)

6 Programmable Inputs

Page 60: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

60 March 31, 2008

MPS 6 Motor Protection Analog Output

1 Configurable analog output to:

I1 (RMS current of phase 1), % of motor FLC.

I2 (RMS current of phase 2), % of motor FLC.

I3 (RMS current of phase 3), % of motor FLC.

Average (RMS) of : I1,I2,I3. % of motor FLC.

Max (RMS) of : I1,I2,I3. % of motor FLC.

I0 (Ground fault RMS leakage current).

% of motor FLC.

% of Rated Line Voltage.

Page 61: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

61 March 31, 2008

MPS 6 Motor Protection Analog Output Cont.

% of motor FLC.

Power, % of rated Power.

Vp1 (Phase 1 to Neutral RMS Voltage).

Power Factor (*100).

Thermal Capacity, %.

Max of T1,T2,T3. °C.

Page 62: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

62 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 63: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

63 March 31, 2008

MPC 6

Protection Relay

Page 64: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

64 March 31, 2008

MPC-6 Motor Protection & Control Relay

Universal motor protection and Controller relay for standard 3 phase motors

Advanced motor protection and supervision

Sampling rate 0.5 ms, RMS.

Current based protection

Advanced thermal modeling algorithm

Six Digital Inputs

One thermal sensors

Statistical data

Programmable Alarm or trip

RS485 MODBUS communication

Page 65: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

65 March 31, 2008

MPC-6 Wiring Diagram

Page 66: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

66 March 31, 2008

MPC-6 Protection Functions

Excessive number of starts (adjust time period)

Start inhibit period

Max. start time

Load increase

Under Current

Over-current (level 1) - Jam

Over-current (level 2) - short

Trip inhibit

Thermal Overload (level 1 & 2)

Unbalance Current

Ground Fault

Over/Under Voltage

Over temperature

Contactor Status

Page 67: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

67 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 68: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

68 March 31, 2008

TPR 6

Temperature Protection Relay

Page 69: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

69 March 31, 2008

TPR-6 Temperature Protection Relay

Monitoring 6 to 14 temperature sensors (RTD/Thermistor).

The TPR-6 accurately creates “Thermal Levels” of the heat increase to protect the motor from abnormal heat in the windings and or bearings.

Self test procedure protects against disconnected sensors and operator faults.

Page 70: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

70 March 31, 2008

TPR-6 Temperature Protection Relay

Advanced microprocessor based circuitry

Display of RTDs or Thermistors Operating Data, Fault and Statistics.

Programmable inputs and outputs

RS 485 communication, MODBUS protocol, for remote setting and supervision

Easy installation & friendly operation

Two protection levels for Alarm and Trip

Selection between Trip and Trip fail-safe

Analogue Output related to any input or inputs combination

RTD / Thermistor selection via Dip Switches

Disconnected sensor protection

Page 71: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

71 March 31, 2008

TPR-6 Temperature Protection Relay

RTD / Thermistor Selection (Any Input)

Thermistor PTC / NTC selection (Any Thermistor Input)

Over temperature Alarm Input number 1..14

Over temperature Trip Input number 1..14

Continuous analog output signal

External fault 1 (from N.O/N.C. contact)

External fault 2 (from N.O/N.C. contact)

Page 72: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

72 March 31, 2008

TPR-6 Temperature Protection Relay

Each protection can be assigned to the following functions:

Alarm only - Relay A

Trip only – Relay B

Alarm & Trip

Disabled

Enabling Auto Reset

Programmable Relay C

Page 73: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

73 March 31, 2008

TPR-6 Typical Application

Motor 3

PC Supervision

SCADA software

L1 L2

L3

6 or 14 RTD or

Thermistor

sensor

TPR-6

Any

Starting

system

Page 74: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

74 March 31, 2008

TPR-6 Typical Connections

TPR - 6 / 6-14

Alarm Relay: Fail-safe Logic

8A/250V/2000VA

1

3

2

4

6

5

7

9

8

10

12

11

Trip Relay: Prog. Trip/ Trip Fail-safe

8A/250V/2000VA

Relay C: Prog. Dedicated Faults

8A/250V/2000VA

Relay D: Prog. Dedicated Faults

8A/250V/2000VA

Fail-Safe Alarm, when TPR mains

is connected and no alarm exists

terminals 1 & 2 are closed.

RS 48547

46

Aux. Power Supply

110V/240VAC

20 ~19 N

18

+

-

T1-T6

RTD or Thermistor

(PTC or NTC)

Standard

52

51

53

59

58

57

61

60

62

65

64

63

56

55

54

Analogue

Output49

48 +

-

T1

T2

T3

T4

T5

67

66

68

26

25

24

28

27

29

32

31

30

23

22

21

T6

T7

T8

T9

T10

34

33

35

41

40

39

43

42

44

38

37

36

T11

T12

T13

T14

T7-T14

RTD or Thermistor

(PTC or NTC)

Optional

Program Input - 1 (Reset, External Fault)

Program Input - 2 (Reset, External Fault)

Common15

AC AC 110 or 230 Vac

14

13

Warning

* The analogue output circuit is

isolated as a group together with

the RS485 communication.

When using both connections,

verify that analogue out user (or

RS-485 user) is using isolated

circuitry.

* Connect all shield wires to

Ground. (A short busbar may be

used).

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Page 75: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

75 March 31, 2008

Meeting content Solcon Products Overview

Motor Protection Relay - Protection functions

Motor Protection Relay - Tripping & Alarm Options

MPS as a Controller

MPS 3000 Special Features

MPS 6 Motor Protection relay

MPC 6 Protection relay

TPR 6 Temperature Protection relay

MIP 6 Motor Insulation Protection relay

MPS 3000 HMI Setting

Page 76: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

76 March 31, 2008

MPI 6

Insulation Protection Relay

Page 77: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

77 March 31, 2008

Motor Insulation Protection – MIP- 6

Page 78: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

78 March 31, 2008

MIP- 6 Main Features Monitors deterioration in motor insulation level for low and medium voltage motors.

Monitoring while motors are de-energized.

Automatic operation.

Programmable parameters.

Measures the motors’ insulation resistance to ground and displays the actual and average highs and lows along a predefined period of time.

Measured range 0.1-20 MΩ.

Low voltage version and medium voltage version.

Six programmable relays provide digital output signals

RS-485 communication port provides real time information.

Optional 4-20mA analogue output is available as well.

Optional real time clock for insulation time stamp.

Optional software for insulation level average monitoring up to 10 years

Control voltage: 120V-230VDC/AC 50/60HZ +10% -15%

Temperature Range 0°C to +50°C (default - all units), -10°C to +60°C (by special order)

Page 79: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

79 March 31, 2008

MIP- 6 Main Connection Diagram

Page 80: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

80 March 31, 2008

MIP- 6 Resistor Box

Medium Voltage resistor box:

RU-7 – Up to 7.2kV

RU-13 – Up to 13.8kV

Page 81: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

81 March 31, 2008

MIP- 6 Key Pad Programming Options marked:

Test ins. NO Test ins. NC Test line Remote reset Authorized key Emergency start Ext. fault NO Ext. fault NO

Options marked:

Trip fail-safe Alarm Alarm fail-safe Fault Fault fail-safe Ins. Lvl<range A Ins. Lvl<range B Ins. Lvl<range c Ins. Lvl<range D Ins. Test active Ins. Test not active Test command on Tripping & alarm

Options marked:

Ins. Ave. 1hr Ins. Ave. 24hrs Ins. Ave. 1mnth

INSULATION PARA.

*** SETTINGS ***

WAIT BRFORE TEST

1-960min(2)

INSUL. TRIP LVL

0.2-25MΩ (1)

INSUL. TRIP DLY

0-120 sec (60)

INSUL. ALARM LVL

0.2-25MΩ (2)

INSUL. ALARM DLY

0-300 sec (200)

INSUL. RANGE A

0.2-25MΩ (4)

INSUL. RANGE B

0.2-25MΩ (6)

INSUL. RANGE C

0.2-25MΩ (8)

INSUL. RANGE D

0.2-25MΩ (10)

DISPLAY MODE

User1-3 (1)

STORE ENABLE

I/O PARAMETERS

CONFIG. INPUT A

CONFIG. INPUT B

(Test ins. NO)

CONFIG. INPUT C

(Test ins. NC)

CONFIG. INPUT D

(Test line)

CONFIG. INPUT E

( Remote reset)

CONFIG. INPUT F

(Authorized key)

PARAM. SETTINGS

Lock/Not locked

CONFIG. OUTPUT A

Ins. Lvl<range A

CONFIG. OUTPUT B

Ins. Lvl<range B

CONFIG. OUTPUT C

Ins. Lvl<range c

CONFIG. OUTPUT D

Ins. Lvl<range D

CONFIG. OUTPUT E

(Alarm)

CONFIG. OUTPUT F

(Trip)

OUTPUT DELAY A

0-3600 sec (600)

OUTPUT DELAY B

0-3600 sec (600)

OUTPUT DELAY C

0-3600 sec (600)

OUTPUT DELAY D

0-3600 sec (600)

OUTPUT DELAY E

0-3600 sec (300)

OUTPUT DELAY F

0-3600 sec (120)

ANALOG OUT TYPE

0-20/4-20mA (4-20)

ANLOG OUT PARAM.

(Ins. Ave. 1hr)

ANLOG OUT MIN.

0-1MΩ (0)

ANLOG OUT MAX

1-50MΩ (20)

Page 82: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

82 March 31, 2008

MIP- 6 Key Pad Programming Cont.

TRIPPING / ALARM

***OPTIONS***

TRIP: ENABLE

TRIP: DISABLE

ALARM: ENABLE

ALARM: DISABLE

AUTO RST: ENABLE

AUTO RST: DSABL

PANEL RST: ENABL

PANEL RST: DSABL

REMOT RST: ENABL

REMOT RST: DSABL

OUTPUT A: ENABLE

OUTPUT A: DISABL

OUTPUT B: ENABLE

OUTPUT B: DISABL

OUTPUT C: ENABLE

OUTPUT C: DISABL

COMMUNICATION P.

BAUD RATE

9200

ADDRESS NUMBER

off

S.LINK PAR. SAVE

Disable

SER.LINK CONTROL

Disable

FRONT COM ADDRES

Off

MEASURED DATA

- **** -

INSULATION RES.

5MΩ

1HOUR AVG. INSUL

4MΩ

24HOUR AVG.INSUL

4MΩ

1MNTH AVG. INSUL

4MΩ

120 MNTH AVG.INSUL

4MΩ

IN # 1 2 3 4 5 6

0 0 1 0 0 0

OUT# 1 2 3 4 5 6

0 0 1 0 1 0

Page 83: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

83 March 31, 2008

MIP- 6 Key Pad Programming Cont.

STATISTICAL DATA

TOTAL MEASURE T.

2000 hrs

TOTAL # OF TRIPS

5

MINIMUM INSUL.

1MΩ

MAXIMUM INSUL. R

10MΩ

FAULT DATA

LAST TRIP

LAST ALARM

LAST 10 TRIPS:

FAULT/

MAINTENANCE DATA

RUN SELF TEST

PROGRAM VERSION

STORE NOW

(DEFAULT SETTINGS)

CLEAR

STATISTICAL DATA

REAL TIME

CLOCK ADJ.

Page 84: Motor Protection Relays - FAMETAL · Motor Protection Relay - Protection functions Motor Protection Relay - Tripping & Alarm Options MPS as a Controller MPS 3000 Special Features

84 March 31, 2008

Solcon Configuration Software

SolControl