Tableof ContentsMini Contactors 3 Pole/ AC Operating Coil 12 AMP/ 600V Rated ..................................................4
Mini Thermal Overload Relays...........................................................................................................4
3 Pole/ AC Operating Coil 18 AMP/ 690V Rated .............................................................................. 4
Thermal Overload Relays/ 690V Rated (for 18 AMP) ......................................................................4
3 Pole/ AC & DC Operating Coil 9-40 AMP/690V Rated ..................................................................5
Thermal Overload Relays/ 690V Rated (for 9-40 AMP) ..................................................................5
3 Pole/ AC & DC Operating Coil 50-65 AMP/ 1000V Rated .............................................................6
Thermal Overload Relays/ 690V Rated (for 50-65 AMP) ................................................................6
3 Pole/ AC Operating Coil 75-100 AMP/ 1000V Rated .....................................................................6
Thermal Overload Relays/ 690V Rated (for 75-100 AMP) ..............................................................6
3 Pole/ AC & DC Operating Coil 100-150 AMP/1000V Rated ..........................................................7
Thermal Overload Relays/ 690V Rated (for 100-150 AMP) ............................................................7
3 Pole/ AC & DC Operating Coil 225-400 AMP/1000V Rated .........................................................7
Thermal Overload Relays/ 690V Rated (for 225-400 AMP)............................................................7
4 Pole/ AC Operating Coil 22-40 AMP/690V Rated ..........................................................................8
3 Pole Reversing/ AC & DC Operating Coil 9-22 AMP/ 690V Rated ...............................................8
3 Pole Reversing/ AC & DC Operating Coil 32-100 AMP/ 1000V Rated .........................................8
Electronic Overload Relays ................................................................................................................8
Manual Motor Starters 690V Rated .................................................................................................. 9
Manual Motor Starter Door Disconnects ......................................................................................... 9
Manual Motor Starter Direct Adapters ............................................................................................. 9
Mechanical Latching Blocks ...............................................................................................................10
Auxiliary Contacts ............................................................................................................................... 10
Contactor Accessories ........................................................................................................................ 10
Mechanical Interlocks ......................................................................................................................... 10
Power Reversing Wire Sets.................................................................................................................11
Overload Accessories ..........................................................................................................................11
MCG | 11675 SW TOM MACKIE BLVD. | PORT ST. LUCIE, FL 34987 | 772.878.4944 | WWW.MCG-USA.COM4
Contactors And Overloads
MINI CONTACTORS 3 POLE/ AC OPERATING COIL 12 AMP/ 600V RATED
PART NUMBER AMP (AC3)
1 PHASE AT 115V
1 PHASEAT 230V
3 PHASE AT 208V
3 PHASE AT 230V
3 PHASE AT 460 V
NEMA SIZE
EQUIV.
AUX. CONTACTS
(NO)
AUX. CONTACTS
(NC)
MCL-12/10__12 12 0.75 2 3 5 7.5 00 1 0
AC COILS REPLACE ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC - - -
Code 24V 120V 208V 240V 277V 480V - - -
MINI THERMAL OVERLOAD RELAYS
PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
MCOL-12M/3-0.16 0.1 0.16 MCL-12/10
MCOL-12M/3-0.25 0.16 0.25 MCL-12/10
MCOL-12M/3-0.4 0.25 0.4 MCL-12/10
MCOL-12M/3-0.63 0.4 0.63 MCL-12/10
MCOL-12M/3-1 0.63 1 MCL-12/10
MCOL-12M/3-1.6 1 1.6 MCL-12/10
MCOL-12M/3-2.5 1.6 2.5 MCL-12/10
MCOL-12M/3-4 2.5 4 MCL-12/10
MCOL-12M/3-6 4 6 MCL-12/10
MCOL-12M/3-8 5 8 MCL-12/10
MCOL-12M/3-9 6 9 MCL-12/10
MCOL-12M/3-10 7 10 MCL-12/10
3 POLE/ AC OPERATING COIL 18 AMP/ 690V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASEAT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX. CONTACTS
(NO)
AUX.CONTACTS
(NC)
MCG-18/1A-__ 18 1 3 7.5 7.5 10 1 1 0
AC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC - - -
Code 24V 120V 208V 240V 277V 480V - - -
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-12/3H-0.16 0.1 0.16 MCG-18/1A
OLH-12/3H-0.25 0.16 0.25 MCG-18/1A
OLH-12/3H-0.4 0.25 0.4 MCG-18/1A
OLH-12/3H-0.63 0.4 0.63 MCG-18/1A
OLH-12/3H-1 0.63 1 MCG-18/1A
OLH-12/3H-1.6 1 1.6 MCG-18/1A
OLH-12/3H-2.5 1.6 2.5 MCG-18/1A
OLH-12/3H-4 2.5 4 MCG-18/1A
STANDARDS SUBJECT TO CHANGE. VISIT WWW.MCG-USA .COM FOR CURRENT INFORMATION. 5
Contactors And Overloads
3 POLE/ AC & DC OPERATING COIL 9-40 AMP/ 690V RATEDPART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASEAT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX.CONTACTS
(NO)
AUX.CONTACTS
(NC)
MCG-09/11-__ 9 0.5 1.5 2 3 5 00 1 1
MCG-12/11-__ 12 0.75 2 3 5 7.5 0 1 1
MCG-18/11-__ 18 1 3 7.5 7.5 10 1 1 1
MCG-22/11-__ 22 2 3 7.5 10 15 - 1 1
MCG-32/11-__ 32 2 5 7.5 10 20 1P 1 1
MCG-40/11-__ 40 2 5 15 15 30 2 1 1
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC -
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V -
PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-12/3H-6 4 6 MCG-18/1A
OLH-12/3H-8 5 8 MCG-18/1A
OLH-12/3H-9 6 9 MCG-18/1A
OLH-12/3H-10 7 10 MCG-18/1A
OLH-12/3H-13 9 13 MCG-18/1A
OLH-12/3H-18 12 18 MCG-18/1A
THERMAL OVERLOAD RELAYS/690V RATED
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-32/3H-0.16 0.1 0.16 MCG-9/11-MCG-40/11
OLH-32/3H-0.25 0.16 0.25 MCG-9/11-MCG-40/11
OLH-32/3H-0.4 0.25 0.4 MCG-9/11-MCG-40/11
OLH-32/3H-0.63 0.4 0.63 MCG-9/11-MCG-40/11
OLH-32/3H-1 0.63 1 MCG-9/11-MCG-40/11
OLH-32/3H-1.6 1 1.6 MCG-9/11-MCG-40/11
OLH-32/3H-2.5 1.6 2.5 MCG-9/11-MCG-40/11
OLH-32/3H-4 2.5 4 MCG-9/11-MCG-40/11
OLH-32/3H-6 4 6 MCG-9/11-MCG-40/11
OLH-32/3H-8 5 8 MCG-9/11-MCG-40/11
OLH-32/3H-9 6 9 MCG-9/11-MCG-40/11
OLH-32/3H-10 7 10 MCG-9/11-MCG-40/11
OLH-32/3H-13 9 13 MCG-9/11-MCG-40/11
OLH-32/3H-18 12 18 MCG-9/11-MCG-40/11
OLH-32/3H-22 16 22 MCG-9/11-MCG-40/11
OLH-32/3H-25 18 25 MCG-9/11-MCG-40/11
OLH-32/3H-32 22 32 MCG-9/11-MCG-40/11
OLH-32/3H-40 28 40 MCG-9/11-MCG-40/11
MCG | 11675 SW TOM MACKIE BLVD. | PORT ST. LUCIE, FL 34987 | 772.878.4944 | WWW.MCG-USA.COM6
Contactors And Overloads
3 POLE/ AC & DC OPERATING COIL 50-65 AMP/ 1000V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX. CONTACTS
(NO)
AUX.CONTACTS
(NC)
MCG-50/11-__ 50 3 10 20 25 40 2 1 1
MCG-65/11-__ 65 5 15 25 30 50 2 1 1
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC -
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V -
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-63/3H-25 18 25 MCG-50/11-MCG-65/11
OLH-63/3H-36 24 36 MCG-50/11-MCG-65/11
OLH-63/3H-40 28 40 MCG-50/11-MCG-65/11
OLH-63/3H-50 34 50 MCG-50/11-MCG-65/11
OLH-63/3H-65 45 65 MCG-50/11-MCG-65/11
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-95/3H-40 28 40 MCG-75/11-MCG-100/11
OLH-95/3H-50 34 50 MCG-75/11-MCG-100/11
OLH-95/3H-65 45 65 MCG-75/11-MCG-100/11
OLH-95/3H-75 54 75 MCG-75/11-MCG-100/11
OLH-95/3H-85 63 85 MCG-75/11-MCG-100/11
OLH-95/3H-95 70 95 MCG-75/11-MCG-100/11
OLH-95/3H-100 80 100 MCG-75/11-MCG-100/11
3 POLE/ AC & DC OPERATING COIL 75-100 AMP/ 1000V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX.CONTACTS
(NO)
AUX.CONTACTS
(NC)
MCG-75/11-__ 75 5 15 25 30 50 2 1 1
MCG-85/11-__ 85 7.5 15 30 40 60 3 1 1
MCG-100/11-__ 100 10 20 30 40 75 3 1 1
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC -
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V -
STANDARDS SUBJECT TO CHANGE. VISIT WWW.MCG-USA .COM FOR CURRENT INFORMATION. 7
Contactors And Overloads
3 POLE/ AC & DC OPERATING COIL 100-150 AMP/ 1000V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX. CONTACTS
(NO)
AUX. CONTACTS
(NC)
MCG-130/11-__ 130 10 20 40 40 75 3 1 1
MCG-150/11-__ 150 15 25 40 50 100 4 1 1
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC -
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V -
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-150/3H-85 63 85 MCG-130/11-MCG-150/11
OLH-150/3H-105 80 105 MCG-130/11-MCG-150/11
OLH-150/3H-130 95 130 MCG-130/11-MCG-150/11
OLH-150/3H-150 110 150 MCG-130/11-MCG-150/11
3 POLE/ AC & DC OPERATING COIL 225-400 AMP/ 1000V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX.CONTACTS
(NO)
AUX. CONTACTS
(NC)
MCG-225/22-__ 225 15 40 60 75 150 4 2 2
MCG-265/22-__ 265 - - 75 100 200 5 2 2
MCG-330/22-__ 330 - - 100 100 200 5 2 2
MCG-440/22-__ 400 - - 125 150 300 5 2 2
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 24V AC/DC 100-240V AC
380-450V AC - - - - - -
Code 24V ACDC 100MV 440MVc - - - - - -
THERMAL OVERLOAD RELAYS/ 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) COMPATIBILITY
OLH-225/3H-125 85 125 MCG-225/22
OLH-225/3H-160 100 160 MCG-225/22
OLH-225/3H-185 120 185 MCG-225/22
OLH-225/3H-240 160 240 MCG-225/22
OLH-400/3H-185 120 185 MCG-265/22-MCG-440/22
OLH-400/3H-240 160 240 MCG-265/22-MCG-440/22
OLH-400/3H-330 200 330 MCG-265/22-MCG-440/22
OLH-400/3H-400 260 400 MCG-265/22-MCG-440/22
Hardware included
MCG | 11675 SW TOM MACKIE BLVD. | PORT ST. LUCIE, FL 34987 | 772.878.4944 | WWW.MCG-USA.COM8
Contactors And Overloads
3 POLE REVERSING/ AC & DC OPERATING COIL 9-22 AMP/ 690V RATED PART NUMBER
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE EQUIV.
NEMA SIZE EQUIV.
MCG-09RV-__ 9 0.5 1.5 2 3 5 00 -
MCG-12RV-__ 12 0.75 2 3 5 7.5 0 -
MCG-18RV-__ 18 1 3 7.5 7.5 10 1 -
MCG-22RV-__ 22 2 3 7.5 10 15 - -
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V
3 POLE REVERSING/ AC & DC OPERATING COIL 32-100 AMP/ 1000V RATED PART NUMBER AMP (AC3) 1 PHASE
AT 115V1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
MCG-32RV-__ 32 2 5 7.5 10 20 1P -
MCG-40RV-__ 40 2 5 15 15 30 2 -
MCG-50RV-__ 50 3 10 20 25 40 2 -
MCG-65RV-__ 65 5 15 25 30 50 2 -
MCG-75RV-__ 75 5 15 25 30 50 2 -
MCG-85RV-__ 85 7.5 15 30 40 60 3 -
MCG-100RV-__ 100 10 20 30 40 75 3 -
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V
ELECTRONIC OVERLOAD RELAYS PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) TYPE COMPATIBILITY
EOL22-3S-1.5 0. 1.5 Screw -
EOL22-3T-1.5 0.3 1.5 Tunnel -
EOL22-3S-5 1 5 Screw --
EOL22-3T-5 1 5 Tunnel
EOL22-3S-22 4 22 Screw -
EOL22-3T-22 4 22 Tunnel -
EOL22P-22 4 22 Pin MCG-22/11
EOL40-3S-20 4 20 Screw -
EOL40-3T-20 4 20 Tunnel -
EOL40-3S-40 8 40 Screw -
EOL40-3T-40 8 40 Tunnel -
EOL40-3P-40 8 40 Pin MCG-32/11-MCG-40/11
EOL80-3S-80 16 80 Screw -
4 POLE/ AC OPERATING COIL 22-40 AMP/ 690V RATED PART NUMBER
AMP (AC3)
1 PHASE AT 115V
1 PHASE AT 230V
3 PHASEAT 208V
3 PHASE AT 230V
3 PHASE AT 460V
NEMA SIZE
EQUIV.
AUX.CONTACTS
(NO)
AUX. CONTACTS
(NC)
MCG-22/4P-__ 22 0.5 1.5 2 3 5 00 1 0
MCG-40/4P-__ 40 0.75 2 3 5 7.5 0 1 0
AC/DC COILS REPLACE __ ABOVE WITH THE REQUIRED COIL VOLTAGE BELOW
Voltage 12V DC 24V DC 24V AC 120V AC 208V AC 240V AC 277V AC 480V AC -
Code 12VDC 24VDC 24V 120V 208V 240V 277V 480V -
STANDARDS SUBJECT TO CHANGE. VISIT WWW.MCG-USA .COM FOR CURRENT INFORMATION. 9
Contactors And Overloads
MANUAL MOTOR STARTERS 690V RATED PART NUMBER CURRENT RANGE (MIN) CURRENT RANGE (MAX) 3 PHASE AT 230V 3 PHASE AT 460V
MMP-32H-0.16 0.1 0.16 - -
MMP-32H-0.25 0.16 0.25 - -
MMP-32H-0.4 0.25 0.4 - -
MMP-32H-0.63 0.4 0.63 - -
MMP-32H-1 0.63 1 - 0.5
MMP-32H-1.6 1 1.6 0.33 0.75
MMP-32H-2.5 1.6 2.5 0.5 1.5
MMP-32H-4 2.5 4 1 2
MMP-32H-6 4 6 1.5 5
MMP-32H-8 5 8 2 5
MMP-32H-10 6 10 3 7.5
MMP-32H-13 9 13 3 7.5
MMP-32H-17 11 17 5 10
MMP-32H-22 14 22 7.5 15
MMP-32H-26 18 26 7.5 15
MMP-32H-32 22 32 10 20
MMP-32H-40 28 40 15 30
MMP-63H-40 28 40 15 30
MMP-63H-50 34 50 15 40
MMP-63H-63 45 63 20 50
MMP-63H-65 47 65 20 50
MMP-100H-63 45 63 20 50
MMP-100H-75 55 75 25 60
MMP-100H-90 70 90 30 75
MMP-100H-100 80 100 45 75
MANUAL MOTOR STARTER DOOR DISCONNECTS PART NUMBER DESCRIPTION SIZE (IN/MM)
MEH32-115 Disconnect Handle for MMP 32H 4.5/115
MEH32-315 Disconnect Handle for MMP 32H 12/115
MEH63-115 Disconnect Handle for MMP 63H 4.5/115
MEH63-315 Disconnect Handle for MMP 63H 12/315
MEH100-315 Disconnect Handle for MMP 100H 12/315
MANUAL MOTOR STARTER DIRECT ADAPTERS PART NUMBER COMPATIBILITY
(MANUAL MOTOR STARTER)COMPATIBILITY
(CONTACTOR SIZE)COMPATIBILITY
(COIL (V))
MCG-DA32H-12AC MMP-32H MCG-12 AC
MCG-DA32H-12DC MMP-32H MCG-12 DC
MCG-DA32H-22AC MMP-32H MCG-22 AC
MCG-DA32H-22DC MMP-32H MCG-22 DC
MCG-DA32H-40AC MMP-32H MCG-40 AC
MCG-DA32H-40DC MMP-32H MCG-40 DC
MCG-DA63H-65AC MMP-63H MCG-65 AC
MCG | 11675 SW TOM MACKIE BLVD. | PORT ST. LUCIE, FL 34987 | 772.878.4944 | WWW.MCG-USA.COM10
Contactors And Overloads
MECHANICAL LATCHING BLOCKS PART NUMBER VOLTAGE COMPATIBILITY
MCG-65ML-24VACDC 24V/ 24V DC MCG-09-MCG-65
MCG-65ML-120V 110-120V AC MCG-09-MCG-65
MCG-65ML-240V 220-240V AC MCG-09-MCG-65
MCG-65ML-440V 380-440V AC MCG-09-MCG-65
MCG-150ML-24VACDC 24VAC-240VDC MCG-75-MCG-150
MCG-150ML-120V 110-120V AC MCG-75-MCG-150
MCG-150ML-240V 24VAC-240VDC MCG-75-MCG-150
MCG-150ML-440V 380-440V AC MCG-75-MCG-150
MCG-225ML-100V 100-127V AC MCG-185-MCG-225
MCG-225ML-200V 200-240V AC MCG-185-MCG-225
MCG-400ML-100V 100-127V AC MCG-265-MCG-400
MCG-400ML-200V 200-240V AC MCG-265-MCG-400
AUXILIARY CONTACTS PART NUMBER MOUNTING POSITION COMPATIBILITY AUX.CONTACTS (NO) AUX. CONTACTS (NC)
MMP-FMA-02 Front Manual Motor Starters 0 2
MMP-SMA-02 Side Manual Motor Starters 0 2
MMP-FMA-11 Front Manual Motor Starters 1 1
MMP-SMA-11 Side Manual Motor Starters 1 1
MMP-FMA-20 Front Manual Motor Starters 2 0
MMP-SMA-20 Side Manual Motor Starters 2 0
MCG-150/FMA-02 Front MCG-09-MCG-150 0 2
MCG-150/FMA-04 Front MCG-09-MCG-150 0 4
MCG-150/FMA-11 Front MCG-09-MCG-150 1 1
MCG-150/SMA-11 Side MCG-09-MCG-150 1 1
MCG-150/FMA-13 Front MCG-09-MCG-150 1 3
MCG-150/FMA-20 Front MCG-09-MCG-150 2 0
MCG-150/FMA-22 Front MCG-09-MCG-150 2 2
MCG-150/FMA-31 Front MCG-09-MCG-150 3 1
MCG-150/FMA-40 Front MCG-09-MCG-150 4 0
MCG-150/SMA-11 Side MCG-225-MCG-440 1 1
CONTACTOR ACCESSORIES PART NUMBER DESCRIPTION
MCG-BAR-185-400-4P Barrier Unit 4 Pack for use with MCG-185-MCG-400
MCG-LK-185-225 Lug Kit for MCG-185 & MCG-225
MCG-TSC-185-225 Terminal Covers for MCG-185 & MCG-225
MSG-LK-265-400 Lug Kit for MCG-265, MCG-330 & MCG-400
MSG-TSC-265-400 Terminal Covers for MCG-265, MCG-330 & MCG-400
MECHANICAL INTERLOCKS PART NUMBER COMPATIBILITY
MCL-MILU MCL-12
MCG-MILU-11 MCG-09-MCG-150
STANDARDS SUBJECT TO CHANGE. VISIT WWW.MCG-USA .COM FOR CURRENT INFORMATION. 11
Contactors And Overloads
POWER REVERSING WIRE SETS PART NUMBER COMPATIBILITY
MCG-RWK/9-22 MCG-09, MCG-12, MCG-18 & MCG-22
MCG-RWK/32-40 MCG-32 & MCG-40
MCG-RWK/50-65 MCG-50 & MCG-65
MCG-RWK/75-100 MCG-75, MCG-85 & MCG-100
OVERLOAD ACCESSORIES PART NUMBER DESCRIPTION LENGTH (IN/MM)
RRU-MT95-400 Remote Reset Unit for OL up to 95A 15.75/400
RRU-MT95-500 Remote Reset Unit for OL up to 95A 19.66/500
RRU-MT95-600 Remote Reset Unit for OL up to 95A 23.66/600
RRU-MT95-700 Remote Reset Unit for OL up to 95A 27.5/700
RRU-MT95-900 Remote Reset Unit for OL up to 95A 35.43/900
USAPrinted in
A DIVISION OF
Visit www.cityelectricsupply.com to find a branch near you.
MCG products are available exclusively at City Electric Supply.
MCG CAT MOTOR STARTER
05438481019377500543-8481
www.mcg-usa.com
11675 Tom Mackie Blvd.Port St. Lucie, Fl 34987P. 772.878.4944