motori per aree pericolose

52
MarelliMotori ASI.CT.028.2 GB D5 SERIES Motors for Hazardous Areas

Upload: maida-wahid

Post on 22-Dec-2015

240 views

Category:

Documents


5 download

DESCRIPTION

Motor detail

TRANSCRIPT

Page 1: Motori Per Aree Pericolose

MarelliMotori

ASI.CT.028.2 GB

D5 SERIES

Motors forHazardous Areas

Page 2: Motori Per Aree Pericolose

MarelliMotori is part of the FKI group of companies serving the worldin the sectors of power generation, transmission and distribution.With over one hundred years of experience, MarelliMotori is a namesynonymous with Quality and Manufacturing Excellence in theproduction of rotating machines.

MarelliMotori is recognised as a leading supplier to the Industrial,Petrochemical and Marine sectors, offering a complete range ofstandard and custom solutions for low and medium voltage motorsand generators.

Our products are backed by an organisation of skilled people dedicated toproviding the high standard of design, sales, service and technical supportdemanded by our customers. Our ability to offer flexible and rapid solutions isan integral part of achieving MarelliMotori’s goal of Total Customer Satisfaction.

Page 3: Motori Per Aree Pericolose

1

INDEX Page

GENERAL ASPECTS OF THE ATEX DIRECTIVE

DEFINITIONS

MARKINGS

STANDARDS

NOMENCLATURE OF D5 SERIES MOTORS

EXAMPLES OF MARKINGS

PRODUCT CODE STRUCTURE

MOUNTINGS AND POSITIONS

MATERIALS

BALANCING AND VIBRATION GRADES

NOISE

BEARINGS

LUBRICATION INTERVALS

TERMINAL BOX AND CABLE ENTRANCE

PROTECTIVE TREATMENTS

THERMAL PROTECTIONS

GROUNDING

COUPLING

ANTICONDENSATION HEATERS

CONDENSATION DRAINAGE

CONNECTION DIAGRAMS

VOLTAGE AND FREQUENCY

OUTPUTS AND DERATINGS

EFFICIENCY AND POWER FACTOR

ELECTRICAL AND MECHANICAL TOLERANCES

STANDARD AND SPECIAL TESTS

MOTORS FED BY FREQUENCY CONVERTER

SELF-VENTILATED MOTORS

MOTORS WITH FORCED VENTILATION

TECHNICAL DATA – MAINS OPERATION – GROUP IIB – SINGLE SPEED

TECHNICAL DATA – FREQUENCY CONVERTER OPERATION

TECHNICAL DATA – MAINS OPERATION – GROUP IIB – DOUBLE SPEED

TECHNICAL DATA – MAINS OPERATION – GROUP IIC – SINGLE SPEED

TECHNICAL DATA – MAINS OPERATION – GROUP IIC – DOUBLE SPEED

DIMENSIONS 71 - 132

DIMENSIONS 160 - 315

DIMENSIONS 355 - 400

2

3

4

5

5

6

6

7

8

8

8

9

10

10

11

11

11

12

12

12

13

14

15

15

16

16

17

18

18

19

26

34

37

38

39

43

46

Page 4: Motori Per Aree Pericolose

GROUPS

The electrical apparatus is subdivided into two groups (EN 50014), according to the environments in which the equipment will operate.

CATEGORIES

Each group is classified into categories, according to the level of protection the apparatus must have:

Level of ProtectionGroupI

Category M1

Very high

M2

High

In the presence of explosiveatmosphere The apparatus must remain operative The electrical supply to the equipment

must be interrupted

Level of Protection

GroupII

Category 1

Very high

2

High

3

Presence of explosiveatmosphere

Zones in which theequipment may be fed

and may operate

High probability(always, often, forextended periods)

0, 1, 2and/or 20, 21, 22

Probable

only 1, 2and/or 21, 22

Normal

Low probability(rare and for a short time)

only 2and/or 22

Environment

Group I II

Used in subterranean mines and on the surface of mines in thepresence of firedump and/or combustible dust.

Explosive atmospheres other than mines; surface industries.

2

GENERAL ASPECTS OF THE ATEX DIRECTIVE

The directive 94/9/EC, better known as ATEX from the French term ATmosphères EXplosibles, is a European Community Directive, which defines the minimum healthand safety requirements for apparatus intended for use in potentially dangerous environments. The directive is adopted by the European Union (EU) to facilitate freetrade in the EU of products to which the Directive applies.It conforms to the safety demands in essence by:• The application of harmonised specific standards,• The EC-type examination of products from a notified body, resulting in the appropriate certification,• The manufacture of the product under a quality management system approved by a notified body.

In order to use electrical equipment in a potentially explosive atmosphere, such as combustible air – gas mixtures or combustible or conductive dust, the environmentmust first be classified in accordance with standard EN 60079-10 and with its related guide.The classification, carried out by qualified competent professionals, identifying:• the group of equipment,• the category,• the protection method,• the temperature class, or the maximum surface temperaturecharacteristics of the electrical motors to be used in this application.

DANGEROUS AREAS

The dangerous environments are classified into zones, shown in the following scheme:

Zone 0

Zone 1

Zone 2

Gas Dust Presence of potentially explosive atmosphere

Zone 20

Zone 21

Zone 22

Always present, frequent or lasting long periods during normal operation.The use of electric motors is not allowed.

Incidental presence: likely to occur during normal operation of the equipment.

Accidental presence: unlikely to occur during normal operation of the equipment.

Page 5: Motori Per Aree Pericolose

The equipment belonging to group II is also specified by the nature of the atmosphere and can be arranged into the following categories:

G = mixture of air and gas, vapour or mist D = mixture of air and combustible dust

Gas atmospheres are further divided into three sub – groups, according to the nature of the gas:

A motor belonging to a particular group is also suitable for use in a lower group (e.g. a motor used in group IIB is also suitable for group IIA).

TYPES OF PROTECTION

The EN 60079-10 standard classifies the dangerous areas, while the standard EN 60079-14 defines the compatibility between the protection method with theaforementioned dangerous zones. The types of protection are defined as follows:

Examples of some substancesGroup

acetone, acetic acid, methanol, ethanol, benzene, ethane, methane, propane, toluene, xylene,combustible oil, kerosene, acetaldehyde, ethylbenzene, isoprene.

coke-oven gas, ethylene, ethylene oxide, ethyl ether, formic aldehyde.

hydrogen, acetylene, water gas, carbon sulphur.

II A

II B

II C

TEMPERATURE CLASS

See definition on page 4: “Maximum surface temperature”.

DEGREE OF PROTECTION IP56

Motors of Category 2G operating at a maximum ambient temperature of 40°C can be supplied on request with IP56 protection degree under the following temperature class:• 2 pole motors: temperature class T3• ≥ 4 pole motors: temperature class T3, T4

DEFINITIONS

The present catalogue lists motors for use in potentially explosive atmosphere, relative to:• Group I - Category M2, for motor sizes 160-315;• Group II - Category 2G, 2D.

EXPLOSIVE ATMOSPHERE

Is a mixture of flammable substances in the state of gas, vapour, mist and dust:• with air,• in which, after ignition, combustion spreads throughout the unconsumed mixture.

POTENTIALLY EXPLOSIVE ATMOSPHERE

It is an atmosphere which could become explosive either as a result of local and/or operating environmental conditions.The ATEX directive applies to products for use in this environment.

TYPE OF PROTECTION “d”

The electrical equipment has an enclosure suitable to:• resist the internal pressure arising from the ignition of an explosive mixture within the equipment.• avoid the transmission of the explosion to the external atmosphere in which the equipment is being used.• ensure that the maximum external surface temperature is maintained within the limits specified by the temperature class of the equipment.

TYPE OF PROTECTION – INCREASED SAFETY “e”

A type of protection in which additional measures are applied so as to give increased security against the possibility of• excessive temperature,• the occurrence of arcs and sparks both inside and on external parts of electrical apparatus which does not produce arcs or sparks in normal service.

For mixtures of air and dustFor mixtures of air and gas, vapour or fog

“d” - Flameproof enclosures (EN 50018)

“e” - Increased safety (EN 50019)

“n” - in accordance with standard EN 50021

IP y5 + maximum permitted surface temperature(y=6 for category 2D; y=5 for category 3D).Electrical apparatus intended for use in environments with the presence of combustibledust. (EN 50281-1-1). When only this method of protection is requested, it is notnecessary for the motors to be explosion proof, but in addition to the grade ofprotection mentioned above, they must have a maximum surface temperature limitedto a specified value.

3

Page 6: Motori Per Aree Pericolose

COMBINED TYPE OF PROTECTION “de”

Combines the essential requirements of protection types “d“ and “e” (in accordance with standards EN 50018 and EN 50019) specifically:• motor enclosures with protection “d” (in accordance with standard EN50018);• terminal boxes with increased safety “e” (in accordance with standard EN 50019).

COMBINED CATEGORY 2G/2D

Combines the essential safety requirements:• of protection type “d” (in accordance with standard EN50018),• of the protection mode for electrical apparatus intended for use in environments with the presence of combustible dust, protection degree IP65 (EN50281-1-1).

MAXIMUM SURFACE TEMPERATURE

It is the maximum operating temperature reached in the most unfavourable conditions (but within relative limits) on the surface of the electrical apparatus.For equipment of group I, the maximum surface temperature must not exceed 150°C.The following table is relevant to apparatus of category 2G, which is based on a predetermined temperature classification:

The maximum surface temperature is:• the temperature of the external surfaces, for motors with protection mode “d”,• the temperature of the external surfaces and of the internal points of the terminal box, for motors with protection mode “de”

In a potentially explosive atmosphere, the maximum surface temperature of the equipment must remain lower than the lowest possible spontaneous ignition temperatureof the atmosphere surrounding it.Electrical apparatus of category 2D are classified based the on maximum surface temperature. This catalogue applies to motors having either of the following three maximumsurface temperatures: T 150°C, T 135°C and T 100°C. In the case of atmospheres with combustible dust, the maximum permitted surface temperature depends on: thetype of dust, the thickness of the layer of dust and on a safety factor used according to (EN 50281-1-2).Motors of category 2G can also be used in installations requiring apparatus in category 3G, provided that they comply with the specified temperature class. Likewise,category 2D motors can be used in category 3D installations requiring the same or a higher maximum surface temperature.

MARKINGS

According to the 94/4/EC Directive, motors come with 3 markings giving the indispensable indications to safely use the product. These indications let the user check thecompatibility between the protection mode of the motor and the classification of the area of its installation.The data shown on the nameplate must therefore contain, in addition to the functional information, the 3 markings described below in sequence (CE, specific andsupplementary) and the reference to the notified body in charge of the certification.

CE MARKING

The CE marking indicates that the D5 series motor conforms to all the applicable directives (and specifically to the ATEX directive).It is a declaration of the manufacturer that the product conforms to the applicable directives and that the product conforms to the prototype on the basis of the qualitycheck procedures it was submitted to.The conformity procedure for the apparatus with respect to categories M2 and 2 demands for:• EC-type examination released by a notified body (that issues the relative certification);• product quality assurance (the product must be manufactured under a quality system which was valued and approved by a notified body).

MARKING SPECIFIC TO THE PROTECTION FROM EXPLOSIONS

In accordance with the 94/4/EC directive and EN 50014 standard, the apparatus must be supplied with the markings specific to protection from explosions:

Simbol + GROUP (I or II) + CATEGORY (M2 or 2) + (only for group II) letter G (Gas) and/or D (dust)

Temperature class

Maximum Surface Temperature (°C)

T1

450

T2

300

T3

200

T4

135

T5

100

T6

85

4

Page 7: Motori Per Aree Pericolose

SUPPLEMENTARY MARKING

The supplementary marking, in accordance with the 94/4/EC directive and to the EN 50014 standard, uses the following symbols:

EEx indicating that the product conforms to one or more protection types, subject to the specific European standards;d, e, type of protection;I, II, equipment group with sub-group of gas for group IIT3, temperature class (for category 2G) or maximum surface temperature (for category 2D).IP65 protection degree of the motor enclosure for category 2D.T xxx°C maximum surface temperature for motors of category 2D and 3D.

NOMENCLATURE OF THE D5 SERIES MOTORSThe D5 series motors are divided into the following types:

1: Series name of combined category 2G/2D motors = Series name of category 2G motors.2: The D5A motors can be supplied on request for frequency converter application with maximum surface temperature of T135°C or T150°C.3: Motors available with Temperature Class T3 (D5D, D5E) and Maximum Surface Temperature T150°C (D5B).4: The D5T motors can be supplied on request for frequency converter application with temperature Class T3.

5

(*) Exist as IEC standards.

STANDARDSStandards relevant to electrical apparatus for potentially explosive atmospheres

Title Standard

EN 60034-1 (*)

EN 60034-2 (*)

EN 60034-5 (*)

EN 60034-6 (*)

EN 60034-7 (*)

EN 60034-8 (*)

EN 60034-9 (*)

IEC 60034-11

EN 60034-12 (*)

EN 60034-14 (*)

IEC 38

EN 60072-1 (*)

EN 50347

Rating and Performance

Methods for determining losses and efficiency

Classification of degrees of protection (IP code)

Methods of cooling (IC code)

Classification of type of construction and mounting arrangement (IM code)

Terminal markings and direction of rotation

Noise limits

Built-in thermal protections

Starting performance of rotating electrical machines

Mechanical vibration

Standard Voltages

Dimensions and outputs for electrical machines

General purpose three-phase induction motors having standard dimensions and outputs

General standards for electric motors

Title Standard

EN 50014

EN 50018

EN 50019

EN 50281-1-1Electrical apparatus for use in the presence of combustible dust –Electrical apparatus protected by enclosures – Construction and testing

General requirements

Flameproof enclosure “d”

Increased safety “e”

x

x

xxx

x

xxx

x

D5CD5D (3)

D5XD5E (3)

D5FD5S

D5RD5VD5TD5UD5AD5B (3)

Specific Marking Supplementary Marking

Series (1) Ex Group Category Protection Group Temperature Class(Maximum surface

temperature)

Polarity Supply

single doublet mains inverter

II

II

II

II

II

II

I

II

2G

2G

2G

2G

2G

2G

M2

2D

EEx d

EEx de

EEx dEEx de

EEx d

EEx de

IP 65

II B

II B

II B

II C

II C

II C

I

T3, T4, T5

T3, T4, T5

T3, T4

T3, T4

T3, T4

T3, T4

(T 150°C) (T 135°C)(T 100°C)

x

x

x

x

x

x

xxxx

xxxx

xxxx

xx

xx(4)

(2)

Frame sizewhere

applicable

71 - 400

71 - 400

71 - 400

160 - 315

160 - 315

160 - 315

160 - 315

71 - 400

D5K

D5Y

EEx dEEx deEEx d,EEx de

1: Series name of combined category 2G/2D motors = Series name of category 2G motors.2: The D5A motors can be supplied on request for frequency converter application with maximum surface temperature of T135°C or T150°C.3: Motors available with Temperature Class T3 (D5D, D5E) and Maximum Surface Temperature T150°C (D5B).4: The D5T motors can be supplied on request for frequency converter application with temperature Class T3.

Page 8: Motori Per Aree Pericolose

EXAMPLES OF MARKINGS

The following indicates some examples of markings for D5 series motors

D5X series. SpecificMarking

SupplementaryMarkingCE Marking

- EN 50014 GeneralRequirements

- EN 50018Protection “d”

Category2G

Marking of conformity withRelevant directives

European Commission mark for Ex - product

Equipment GroupEquipment CategoryAtmosphere

TemperatureClass

Sub group of GasGroupType of protectionConformity with standardEN 50014, …

Identification of Notified body(0722 CESI)

0722 II 2 G EEx de II B T3

D5X series.

- EN 50014General requirements

- EN 50018Protection “d”

- EN 50019Increased safety ”e”

0722 II 2 G EEx de II B T3Category

2G

D5T and D5U series.

- EN 50014General requirements

- EN 50018Protection “d”

0722 I M2EEx d ICategory

M2 EEx de I

D5C series - Combined category

- EN 50014General requirements

- EN 50018Protection “d”

- EN 50281-1-1Protection from dust

Category2D

Category2G

IP 65

0722 II 2 G- EEx d II B T3- IP 65 T 150° C

II 2 D

D5A and D5B series.

- EN 50014General requirements

- EN 50281-1-1Protection from dust

0722Category

2DIP 65 IP 65 T 150° CII 2 D

PRODUCT CODE STRUCTUREMarelliMotori products are identified by 13 digit code show on the nameplate.The code is constructed as follows.

Series Housing lengthcode

Mountingarrangement code

Voltagecode

D 5 C 1 6 7 2 A 0 0 0 1 0Frame size

codePolaritycode

Option code given byMarelliMotori

6

Page 9: Motori Per Aree Pericolose

MOUNTINGS AND POSITIONS

Motors are supplied according to type of construction B3, B5, B3B5, B14, B3B14 and V1 compatible with the mounting arrangements shown in table below as definedin IEC 60034-7. Nameplates are marked with the abovementioned type of construction.

7

IM

Code II (Complete)

Mounting category(1-9)

Type of shaft extension(1-9)

Mounting arrangement

B: Horizontal - V: Vertical Mounting code

Code I (Semplified)

IM

IM V1

IM V15

IM V3

IM V36

IM V5

IM V6

IM V18

IM V19

IM 3011

IM 2011

IM 3031

IM2031

IM 1011

IM 1031

IM 3611

IM 3631

Code I Code II

IM B3

IM B35

IM B34

IM B5

IM B6

IM B7

IM B8

IM B14

IM 1001

IM 2001

IM 2101

IM 3001

IM 1051

IM 1061

IM 1071

IM 3601

1)

1) 2)

1) 3)

2)

1)

1)

1)

3)

x

x

x

x

x

x

x

x

71 -

112

132

160

- 25

0

280

- 31

5

355

- 40

0

71 -

112

132

160

- 25

0

280

- 31

5

355

- 40

0

2)

1) 2)

2)

1) 2)

1)

1)

3)

3)

Code I Code II

1) Motors with feet2) Flanged motors: unthreaded through holes3) Flanged motors: threaded dead holes

• StandardX Consults MarelliMotori

Motors from frame size 71 and above are supplied with lifting eye bolts displaced according to type of construction B3 whereas they will be displaced according to type of construction V1only if provided with antirain canopy.

Page 10: Motori Per Aree Pericolose

8

BALANCING AND VIBRATION GRADES

The motors are dynamically balanced with a half key applied to the shaft extension in accordance with standard EN 60034-14 to vibration grade normal (N) in standardconfiguration.Larger vibrations may occur on motors installed at site, due to various factors such as unsuitable foundations or resonance with the driven system. In such casesadditional checks should also be carried out on each element of the installation.Motors can be supplied with reduced (R) or special (S) vibration level on request.The following table indicates the maximum vibration limits with respect to the different shaft heights

Nnormal 600 - 3600

600 - 1800

> 1800 - 3600

600 - 1800

> 1800 - 3600

Vibration grade Rated speed(min -1)

Maximum rms value of vibration speed for shaft height H in mm.[mm/s].

Rreduced

Sspecial

71 ≤ H ≤ 132

1,8

0,71

1,12

0,45

0,71

132 < H ≤ 225

2,8

1,12

1,8

0,71

1,12

250 < H ≤ 400

3,5

1,8

2,8

1,12

1,8

The instrumentation can have a measurement tolerance of ±10%.

NOISE

The following table shows the medium values of A-sound pressure level (LpA) for group IIB motors, measured at a one-metre distance according to standard ISO R1680. The sound levels are measured with the motor running at 50 Hz, in no-load conditions and have a tolerance of 3 dB(A). At 60 Hz the values of sound pressureincrease by approximately 4 dB(A).

718090100112132160

180 M180 L200225250280

315 SM315 M355400

Frame size A-sound pressure level (LpA) [dB(A)]2 poles 4 poles 6 poles 8 poles

LpA LpA LpA LpA6067737776787878-

8084848483838282

5353536158666565696974747778787981

-535661586262-

636366667274747576

-535661586061-

626263637274747073

MATERIALS

The mechanical components used in D5 series motors are made of the materials shown in the table below:

Frame

Aluminium

Alloy

Size

Components

Endshields

Fan cowl

Fan

Terminal Box

71 - 132 160 - 2802 - 6 poles ≥ 8 poles 2 - 4 poles ≥ 6 poles

315 355 - 400

Steel

Cast Iron Steel

Thermoplastic (**) Metal

SteelCast Iron

(*) Steel for EEx d IIC motors.(**) Metal is used for motors of M2 category.

Cast Iron (*)

Page 11: Motori Per Aree Pericolose

9

D-End N-End

Frame Size

6202-2Z6204-2Z6205-2Z6206-2Z6206-2Z6308-2Z

6202-2Z6204-2Z6205-2Z6206-2Z6206-2Z6308-2Z

D-End (*) N-End (*)

718090100112132

(*) Different types can be supplied on D5A and D5B series motors.

Motors from 355 to 400 frame size in standard configuration are equipped with regreasable rolling bearings.The supports are equipped with grease nipples. In standard configuration, the rotor is axially fixed on the N-End side.

For different bearing configurations contact MarelliMotori.

MOUNTING ARRANGEMENT V1 - IM3011Frame Size Poles

355 ÷ 400355400

6217 - C3NU 222 - C3NU 222 - C3

D-End

7217 B6217 - C3 + 7217 B6222 - C3 + 7222 B

N-End

2≥ 4≥ 4

MOUNTING ARRANGEMENT B3 - IM1001Frame Size Poles

355 ÷ 400355400

6217 - C3NU 222 - C3NU 222 - C3

D-End

6217 - C36217 - C36222 - C3

N-End

2≥ 4≥ 4

Frame Size Horizontal

6310-Z-C36310-Z-C36312-Z-C36313-Z-C36314-Z-C36314-Z-C3

NU2217-EC-C36316-C3

NU2219-EC-C3

(*) Different types can be fitted with series D5A and D5B motors.

6209-Z-C36210-Z-C36210-Z-C36213-Z-C36213-Z-C36314-Z-C36314-Z-C36316-C36316-C3

D-End (*) N-End (*)

Vertical Horizontal Vertical

160-180M180 L200225250

280 - 2 poles280 ≥ 4 poles315 - 2 poles315 ≥ 4 poles

Horizontal

NU 210 E-C3NU 210 E-C3NU 212 E-C3NU 213 E-C3NU 214 E-C3

6314-C3NU2217-EC-C3

6316-C3NU2219-EC-C3

6209-2Z-C36210-2Z-C36210-2Z-C36213-2Z-C36213-2Z-C3

6314 C36314-C36316-C36316-C3

D-End (*) N-End (*)

Vertical Horizontal Vertical

Group I M2 and IIB Group IIC

Category 2G group IIB motors from 160 to 315 frame size in standard configuration are equipped with:• single screen prelubricated ball bearings (160 - 250 without regreasing system; 280 - 315 with regreasing system) for group IIB; 160 - 250 frame motorscan be supplied with regreasing system and the relative grease exhausts on request. The N-end bearing is axially preloaded by means of a preload washer.• D-end roller bearing (except for 2 pole motors) and N-end ball bearing for group IIC motors.

BEARINGS

The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction motors, without external forces (radial and/or axial)is in excess of 50,000 hours.The lifetime of bearings is determined by multiple factors and specifically by:• the external loads and level of vibration• the lifetime of the grease (mainly on double screen bearings),• the environmental conditions and working temperature.

Motors with frame sizes from 71 to 132 in standard configuration have doublescreen prelubricated ball bearings.The correspondent grease life under normal operating conditions for a motorwith horizontal shaft, running at 50 Hz and at maximum ambient temperatureof 40°C is:• 10,000 hours in continuous duty for 2 pole motors,• 20,000 hours in continuous duty for 4 pole motors.The axial positioning of the rotor is carried out by means of a preload washerat the N-end, as shown in the diagram to the right.The following table describes the bearing types used on the different framesizes.

Page 12: Motori Per Aree Pericolose

10

TERMINAL BOX AND CABLE ENTRANCE

Motors from 71 to 132 frame size have main terminal box on the right side (when seen from D-end, B3 mounting) and are normally equipped with 6 terminals.The terminal box can be rotated in steps of 90°.

Frame Size

71 ÷ 90100 ÷ 132

Type of terminal

Threaded terminalsThreaded terminals

Terminal thread

M6M6

Cable entrance holes

M25 x 1,5M32 x 1,5

Motors from 160 to 400 frame size have the main terminal box on top (B3 mounting) and are normally equipped with 6 terminals.The terminal box can be rotated in steps of 90°.

The following table indicates the lubrication intervals of motors without regreasing system in standard configuration and the relubrication intervals of motors withregreasing system in standard configuration.The shown values refer to normal operating conditions at a maximum ambient temperature of 40°C.

LUBRICATION INTERVALS

160 - 180200225250

3600 min-1

7000550055005000

Motors without regreasing system - Group IIB

Lubrication Interval (H)

750 min-1900 min-13000 min-1 1800 min-1 1500 min-1 1200 min-1 1000 min-1

7500700070005500

1200011000100009500

14000120001100011000

16000140001400013000

18000160001600014000

21000180001800017000

26000230002200020000

Frame Size

280315

355 - 400 (B3)355 - 400 (V1)

3600 min-1

3200280034002000

Motors with regreasing system - Group IIB

Relubrication Interval (H)

750 min-1900 min-13000 min-1 1800 min-1 1500 min-1 1200 min-1 1000 min-1

4000340040002200

2000170015001500

2200200018001800

2800260022002200

3400300028002800

3800340030003000

4600420036003600

Frame Size

160 - 180200225250280315

3600 min-1

170014001300120032002800

Motors with regreasing system - Group IIC

Relubrication Interval (H)

750 min-1900 min-13000 min-1 1800 min-1 1500 min-1 1200 min-1 1000 min-1

200017001500150040003400

400032003000280022002000

500042003800360028002600

600050004500440034003000

650055005000450038003400

800066006000550046004200

Frame Size

Frame Size

160 - 200225 - 250280 - 315355 - 400

Type of terminal

Threaded terminalsThreaded terminalsThreaded terminalsThreaded terminals

Terminal thread

M6M8

M12M20

Cable entrance holes

(1) Closed with a certified plug, in accordance with Directive 94/4/EC, when not used.

M40x1,5 + M40x1,5 (1)

M50x1,5 + M50x1,5 (1) + M20x1,5 (1)

M75x1,5 + M75x1,5 (1) + M20x1,5 (1)

M75x1,5 + M75x1,5

340028002600240020001700

Page 13: Motori Per Aree Pericolose

PROTECTIVE TREATMENTS

EXTERNAL SURFACES

The standard painting process consists of the application of epoxy-vinyl/polyurethane paint: the surface treatment, material and paint thickness make D5 series motorssuitable for use in standard industrial environments.

A special painting process, consisting of epoxy-vinyl paint followed by polyacrilic paint is available on request. This process is particularly recommended for:• aggressive environments;• outdoor installations where salt is present or environments with the presence of anhydridic gases;• marine installations;The standard finishing colour is RAL 5010. Other RAL and MUNSELL colours are available on request.

Additional built-in thermal protections

(Positive Temperature Coefficient)Thermistors PTC

Platinum resistance thermometersPT100

Motoprotectors with contacts Normally Closed.The disc opens when the winding temperature reaches limits dangerousto the insulation system of the motor.

Type Operating principle Frame sizes where applicable

Bimetallic devices

At the active temperature this device quickly changes its resistancevalue.

Variable linear resistance with the winding temperature, particularlysuitable for a continuous winding temperature monitoring.

90÷400

160÷400

90÷400

INTERNAL SURFACES

The internal parts of the motors are treated with an insulating enamel to prevent motor corrosion due to humidity and agressive substances. Such treatment added tothe impregnation of active parts is an essential requirement for motors intended for use in industrial, tropical-humid environments.

THERMAL PROTECTIONS

The motors must be protected against overload by setting the omnipolar timer to time inversion (EN 60079-14) (timer not scope of MarelliMotori supply). The motorscan however be equipped with additional thermal protections which characteristics are given in the following table.

The intervention temperature of the thermal protection to be selected is dependent on the temperature class and/or on the allowed maximum surface temperature.D5 series motors from frame size 160 and above in standard configuration have 3 PTC with terminals in the main terminal box.All motors for frequency converter application must be equipped with PTC having suitable intervention temperature.In this case, the connection between the temperature-sensitive element to the dedicated protection equipment (not scope of MarelliMotori supply) is mandatory andthe control must be set, so that the motor can be used only when the thermal protection equipment is operative.The use of the motor is dependent on the state of the thermal protections.

GROUNDING

All motors are equipped with two grounding terminals, one inside the terminal box and one outside. Both are dimensioned for connection to suitable earthing wiresconforming to EN 50014 standard.

11

Characteristics ThicknessDescription

Painting

Process

Finishing paint

Standard

On request

Two-component paint formulated with solid epoxy resins modified withvinyl polyamide catalysers ≥ 50 µm

≥ 200 µm

RAL 5010

RAL & MUNSELL colours

Std + additional polyacrilic coat formulated with an aromaticsemialiphatic catalyser

Standard

On request

Page 14: Motori Per Aree Pericolose

COUPLING

Elastic or flexible couplings must be properly done to avoid the transmission of axial and/or radial loads to the motor shaft and bearings.For possible external axial and/or radial loads contact MarelliMotori.

ANTICONDENSATION HEATERS

Motors subject to atmospheric condensation, either through standing idle in damp environments or because of wide ambient temperature variations, may be fitted withanticondensation heaters. They are normally switched on when the supply to the motor is interrupted, heating the motor to avoid water condensation. Normal feedingvoltage is 230V.Motors from frame size 100 and above can be supplied with anticondensation heaters with terminals in main terminal box or, from 160 frame size and above of category2G and of category 2D, with terminals in a separate terminal box. The power values normally used are shown in the table below.

CONDENSATION DRAINAGE

Motors of category 2G from frame size 160 and above can be supplied on request with condensation drainage holes. This option is advisable, for example, in environmentswith high humidity levels and large ambient temperature variations.

Frame Size Power (W)

8

25

50

65

100

200

300

400

100 - 112

132

160 - 180

200 - 250

280

315

355

400

The following table shows some possible configurations of D5 series motors.

std: standard configuration opt: optional(1) Terminals in separate terminal box only. Option not available oncategory M2 motors.

For combination of more than one option contact MarelliMotori.

12

Type ofProtectionFrame Size

opt

opt

opt

std

std

std

std

std

std

90

100 - 132

160 -250

280 - 315

355 - 400

d

de

d

de

d

de

d

de

d

de

PTC (n°3) PT100 (n°3) AnticondensationHeaters PTC+Heaters PT100+Heaters

opt

opt (1)

opt

opt (1)

opt

opt

opt

opt

opt

opt

opt (1)

opt

opt

opt

opt

opt (1)

opt

opt (1)

opt

opt

Page 15: Motori Per Aree Pericolose

CONNECTION DIAGRAMS

Manually OperatedExternal Connection

Diagram

OutlineDiagram

Internal ConnectionDiagram

L31W

2W1U

2U

1V2V

L1

L2L3

1W 1V

L2

1U

L1

L32W

2U

2V

L1

L2

L3

2W 2V

L2

2U

L1

2U 2V 2W

1U 1V 1W

L1 L2 L3

Low Speed

High Speed

2U 2V 2W

1U 1V 1W

L1 L2 L3

L3

W1

W2

V1

V2

L2

U2

U1

L1

L3 W1

W2U1

U2

V1V2

L1

L2

W1V1U1

W2V2U2

W2 U2 V2

U1 V1 W1

L1 L2 L3

W2 U2 V2

U1 V1 W1

L1 L2 L3

13

MOTORS WITH 6TERMINALS

Y / ∆ CONNECTION

TWO SPEED MOTORSWITH 6 TERMINALS

Y/Y AND ∆ / ∆CONNECTIONS

SeparateWindings

Page 16: Motori Per Aree Pericolose

14

CONNECTION DIAGRAMS

Manually OperatedExternal Connection

Diagram

OutlineDiagram

Internal ConnectionDiagram

MOTORI A 6 MORSETTIDOPPIA POLARITÀ

COLLEGAMENTI Y Y / ∆

(Avvolgimento unico)

Low Speed

High Speed

1W1V1U

2W 2V2U

L3

2W

1U

2V

1W

L2

2U

L1

L3

1W

2W

1U

1V

2U

2V

L1

L2

1V

2U 2V 2W

1U 1V 1W

L1 L2 L3

2U 2V 2W

1U 1V 1W

L1 L2 L3

VOLTAGE AND FREQUENCY

The motors described in this catalogue, if not otherwise specified, are designed to operate under feeding voltage of 230V/400V 10% - 50Hz. They are thereforesuitable for use on the following supply voltages:- 220/380V 5%, 50Hz- 230/400V 5% , 50Hz- 240/415V 5%, 50Hzaccording to standard 60034-1, zone A.

The motors can be supplied with different voltages and frequencies on request.

Page 17: Motori Per Aree Pericolose

OUTPUTS AND DERATINGS

The output ratings listed in this catalogue refer to continuous duty S1, rated voltage and frequency, ambient temperature between -20°C and +40°C and altitude upto 1000 m. a.s.l. In different environmental conditions the output ratings of temperature-class-T3 motors can be obtained by applying the derating factors given in thefollowing table:

EFFICIENCY AND POWER FACTOR

The efficiency (η) and power factor (cos ϕ) values referred to rated output are given in the technical data tables for each motor. The values for other loads can beestimated from the following tables.

4/4

cos ϕϕηη ηη cos ϕϕ ηη cos ϕϕ ηη cos ϕϕ

3/4 2/4 1/4

Efficiency (ηη%) and power factor (cos ϕϕ)

979695

93,59392919089888786858483828180797877767574737271706968

65,563,561,559,5

97969594939291908988878685848382818079787776757473727170696866646260

0,910,900,890,880,870,860,850,840,830,820,810,800,790,780,770,760,750,740,730,720,710,700,690,680,670,660,650,640,630,620,610,600,590,58

0,880,870,860,850,840,830,820,810,800,780,760,750,730,730,720,700,690,670,660,650,640,630,620,610,600,580,570,560,550,540,530,520,510,50

929088868584829079

78,578

77,5777674737270

69,569686766646361595857

55,553,55249

47,5

9694,593,5929190898786

85,585

84,5848381

80,5807978767574737271696867666563615957

0,820,800,790,780,770,750,730,720,700,670,660,650,630,600,590,580,560,540,520,510,500,480,470,450,430,410,400,390,380,370,360,350,340,33

0,640,630,600,580,570,550,530,510,490,470,450,430,420,410,400,380,360,360,350,340,340,330,330,320,300,280,270,260,250,240,230,220,210,20

15

Altitude

1,000,970,970,900,860,820,77

1000150020002500300035004000

40 45 50 550,920,890,860,830,790,750,71

0,870,840,820,780,750,710,67

Ambient temperature (°C)

0,960,930,900,860,820,790,74

600,820,790,770,740,700,670,63

Page 18: Motori Per Aree Pericolose

ELECTRICAL TOLERANCES

Electrical tolerances in accordance with standard IEC 60034-1.

Powerfactor

Speed

-1/6 of (1-cosϕ)

Efficiency -15% of (1-η)-10% of (1-η)

± 20%± 30% of guaranteed slip

min. 0,02max. 0,07

Pn ≤ 50 kWPn > 50 kW

Pn ≥ 1 kWPn < 1 kW

Locked rotor torque

Locked rotor current

Pull out torque

+20%

-15%+20%

-10%

of guaranteedvalue

of guaranteedvalue

of guaranteedvalue

MECHANICAL TOLERANCES

Tolerances according to IEC 60072-1 are shown in the following table.The second shaft extension is built only on request.

Part Dimension Tolerance

Shaft Extension

Key

Flange Concentricity

Shaft Height

D-DA

F-FA

N

H

from 11 to 28mm ø j6 / 38 to 48mm ø k6 / 55 to 100mm øm6

h9

up to frame size 132 j6 / greater than 132 h6

up to frame size 250 - 0,5mm / greater than 250 - 1mm

STANDARD AND SPECIAL TESTS

All MarelliMotori products are subject to routine tests carried out in accordance with CEI/IEC standards. The following additional tests can also be carried out on request

Ad

dit

iona

l Tes

t

Basic

• Measurement of winding resistance (cold).• High voltage test plus insulation resistances immediately before and after the test.• Dielectric test.• No load test.

Ext

ra T

est • On-load test with variable voltage.

• Measurement of curve C = f(n).• Measurement of vibration in accordance with IEC 60034-14.• Measurement of noise level, (no load).• Verification of IP protection in accordance with IEC 60034-5.

Complete (= Basic +)

• Locked rotor test.• Full load winding temperature with method by resistance variation.• Determination of efficiency and power factor at , and of load.

16

14

24

34

Page 19: Motori Per Aree Pericolose

MOTORS FED BY FREQUENCY CONVERTER

The operating characteristics of the motors described in this section of the catalogue refer to the electrical supply by frequency converter with a commutating frequencyhigher than 3kHz.Motors fed by inverter and intended for use in installations in potentially explosive atmospheres must be:• explicitly requested for this type of supply,• specifically chosen considering the load and speed range,• using appropriate passive thermal protection (thermistors, PT100), with connection to suitable supply system protection apparatus.• given a nameplate identifying: supply characteristics of the frequency converter, torque and speed range.

The maximum supply frequency value is dependent on the frame and polarity of the motor, as shown in the following table.

For motors ≥ 4 poles and supply frequency between 75-100 Hz contact MarelliMotori.The performances of motors fed by frequency converter are given in the specific tables.

EFFECTS OF INVERTER SUPPLY ON THE MOTOR

A motor supplied by a frequency converter (inverter) does not receive a purely sinusoidal feed (voltage, current), which leads to an increase in:• additional losses,• noise and vibrations,• stresses on the electrical insulation,As well as:• the production of voltages and currents in the bearings,• the need to provide additional solutions to satisfy the EMC requirements for the installation.

ADDITIONAL LOSSES

Additional losses increase the heat of the motor, which may lead to an increase in the temperature of the bearings.These effects must be considered (by using appropriate derating with respect to the supply by the mains), in particular for potentially explosive environments where limitsto the maximum surface temperature are applied.

NOISE VIBRATION

The increase in magnetic noise depends mainly on the commutating frequency of the inverter and as well as the harmonic content.Self-ventilated motors, when running at frequencies higher than the rated value, give an increased noise level due to the increased ventilation. For speed values higherthan the rated one, the maximum speed reachable by the motor or the critical speed of the system must not be exceeded.In this case, the use of separate ventilation is recommended to reduce any possible excessive noise.

EFFECTS ON ELECTRICAL INSULATION

The insulation system in a motor is subjected to an increased dielectric effect when fed by an inverter. Depending on the supply system characteristics, the indicationsgiven in the paragraph “Instructions for the correct use of motors fed by frequency converter” must be considered.

GENERATION OF VOLTAGE AND CURRENT IN THE BEARINGS

The inverter induces high frequency voltages into the shaft, possibly causing bearing currents which must be avoided in all motors for potentially explosive atmospheres.

The paragraph “Instructions for the correct use of motors fed by frequency converter” gives the indications which must be followed for the use of insulatedbearings / supports or of appropriate filters between the inverter and motor to avoid the risk of current circulation in the bearings.D5 seiries motors from 280 to 400 frame size when designed for inverter application, are supplied with insulated N-End bearings.

17

Frame Size N° poles Temperature class T3 Temperature class T4

2

≥ 4

71 to 400

71 to 400

60 Hz

75 Hz

60 Hz

100 Hz

Page 20: Motori Per Aree Pericolose

EMC REQUIREMENTS FOR THE INSTALLATION

The use of cables and connections conforming to EMC (electromagnetic compatibility) recommendations is necessary.Supply cables to the motor must be both shielded and symmetrical.The motor and the driven system must be properly earthed, to avoid possible voltages and currents in the bearings of the motor.The additional instructions given by the inverter manufacturer must also be followed.

INSTRUCTIONS FOR THE CORRECT USE OF MOTORS FED BY FREQUENCY CONVERTER

The type of the inverter and of the filters must be properly selected to guarantee a peak voltage at the motor terminals of less than 1060V.

The following table indicates the solutions to be applied on motors fed by frequency converters. They are classified with respect to the input voltage of the inverter.

(*) Not scope of MarelliMotori supply.

SELF-VENTILATED MOTORS

The ventilation in a self-ventilated motor is a function of the speed of the motor itself (and therefore also of the feeding frequency). Consequently the cooling and noiselevel vary according to the inverter output frequency, thus:• in the frequency range lower than the rated value, a further power derating must be considered (see the relevant graphs in the dedicated section)• in the frequency range higher than the rated value, the noise increases approximately by the values given in the following table:

Voltage UN ≤ 500V UN ≤ 690V

≤ 250 Standard insulation

Reinforced insulation+ Insulated bearing

+ filter dU/dt (*)

Frame Size

Reinforced insulation+ insulated bearing

Reinforced insulation

+ insulated bearing

Standard insulation+ filter dU/dt (*)

Reinforced insulation+ Insulated bearing

+ filter dU/dt (*)+ common mode filter (*)

280 ÷ 315

355 ÷ 400

Frequency [Hz]

Additional noise [dB(A)]

60

4 - 5

75

9

MOTORS WITH FORCED VENTILATION

Forced ventilated motors are equipped with an auxiliary motor which must have a classification compatible with the main one.The use of forced ventilation is recommended in the presence of wide range of speed variation and when constant torques are requested.The operation of the main motor must be made dependent to the correct operation of the forced ventilation unit.

For the correct selection of motors fed by inverters, refer to the corresponding specific tables.

18

160-250280-315S

315M355400

∆I B3 [mm]236

180-220310256325

Forced Ventilated Motor

∆I V1 [mm] ∆p [kg] Type268

255-315---

D5_71 MB4D5_80 MA4D5_80 MA4D5_80 MB4D5_112 M4

Frame size23-3035-45

404095

Force Ventilation Unit

Page 21: Motori Per Aree Pericolose

ASI.CT.027.0 19ASI.CT.027.0

400V 50Hz / 440V 60Hz

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.• Motor not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

3000/3600 min-1 = 2 poles - 50/60 Hz

EEx d IIB, EEx de IIB, IP65

280 S2280 M2

93,694,2

133157

242290

6,87,2

2,32,3

2,72,7

0,3500,416

484517

0,870,88

29602960

35603560

250 M2 93,0 98 177 6,7 2,4 3,0 0,250 3360,872960 3560

225 M2 92,5 80 145 6,6 2,4 3,0 0,225 3040,882960 3560

200 LA2200 LB2

92,092,2

5467

97120

6,86,9

2,32,4

2,93,0

0,1650,180

189209

0,870,87

29452945

35453545

180 M2 90,5 41,8 72 7,0 2,5 3,0 0,048 1540,842930 3530

71 MA271 MB2

69,572,3

1,01,4

1,31,9

4,44,6

2,83,0

--

0,00040,0005

15,317,3

0,780,79

132 SA2132 SB2132 MB2

85,787,087,2

10,914,317,1

18,124,729,5

7,57,87,8

2,52,62,9

2,83,23,6

0,01600,01900,0230

75,881,891,8

0,850,870,87

112 M2 84,4 8,1 13,1 7,2 2,5 2,9 0,0063 55,80,85

80 MA280 MB2

74,177,5

1,82,4

2,63,7

5,65,9

2,42,6

2,32,6

0,00080,0010

20,822,8

0,830,84

90 S290 L2

78,781,1

3,34,7

5,17,4

6,16,4

2,52,7

2,62,8

0,00160,0022

26,832,3

0,840,83

100 LA2 83,0 6,2 9,9 6,8 2,1 2,6 0,0050 48,30,84

27302730

291529152915

2910

28002830

28102850

2900

33303330

351535153515

3510

34003430

34103450

3500

160 MA2160 MB2160 L2

88,489,890,0

21,929,036,7

364960

6,26,67,1

2,12,42,6

2,83,03,0

0,0300,0350,040

115129143

0,820,830,81

292029252925

352035253525

315 SM2315 MA2315 MC2315 MD2

94,394,394,494,7

194235281351

353424513640

6,46,56,56,5

2,42,52,52,5

2,42,52,52,5

0,950,951,121,30

760760827887

0,870,860,870,87

2975297029752980

3575357035753580

•••

83100

60

50

3340

24

0,370,55

68

9,5

4,2

0,751,1

1,62,3

3,2

1216,520

121158192240

7590

55

45

3037

22

0,370,55

5,57,59

4

0,751,1

1,52,2

3

1115

18,5

110132160200

T1 ÷ T4, T 135°C

T1 ÷ T3, T 150°C230280330

355 LX2355 LW2355 LY2

298029802980

94,595,495,8

0,900,900,91

390471547

736896

1056

6,56,56,8

2,02,02,1

2,83,03,0

4,45,16,0

177019502145

280330400

358035803580

•••

375450560

450540630

400 LX2400 LW2400 LY2

•••

298029802980

358035803580

94,595,095,0

0,910,910,91

630752936

120114411793

7,07,07,2

2,22,22,2

2,83,03,0

7,98,9

10,0

278029403150

200250280

355 LX2355 LW2355 LY2

298029802980

94,595,495,8

0,900,900,91

339420464

640800896

6,56,56,8

2,02,02,1

2,83,03,0

4,45,16,0

177019502145

200250280

358035803580

•••

330400500

330400500

400 LX2400 LW2400 LY2

•••

298029802980

358035803580

94,595,095,0

0,910,910,91

555669936

105612811601

7,07,07,2

2,22,22,2

2,83,03,0

7,98,9

10,0

278029403150

T4, T 135°C

Page 22: Motori Per Aree Pericolose

20

400V 50Hz / 440V 60HzEEx d IIB, EEx de IIB, IP65

T1 ÷ T4, T 135°C1500/1800 min-1 = 4 poles - 50/60 Hz

280 S4280 M4

93,793,9

134157

483580

7,07,1

2,52,7

2,32,4

0,8851,060

525584

0,860,88

14801480

17801780

250 M4 93,0 98 356 6,4 2,3 2,6 0,520 3700,871475 1775

225 M4 92,5 82 291 6,5 2,4 2,8 0,410 3320,861475 1775

200 L4

225 S4

91,6

92,5

56

67

195

239

6,4

6,5

2,4

2,3

2,8

2,8

0,180

0,320

205

302

0,84

0,86

1470

1475

1765

1770

180 L4 90,5 41,8 143 6,3 2,4 2,5 0,110 1770,841465 1765

71 MA471 MB4

67,669,5

0,81,1

1,732,6

3,83,8

2,32,5

2,32,5

0,00050,0006

16,317,3

0,680,68

100 LB4 83,0 6,4 20,2 5,5 2,1 2,5 0,0090 50,80,81

80 MA480 MB4

72,073,0

1,52,0

3,85,2

4,64,75

2,62,75

2,42,5

0,00130,0016

21,322,8

0,740,74

90 S490 L4

76,579,1

2,63,4

7,610,3

4,54,7

2,52,7

2,42,5

0,00330,0040

27,331,8

0,790,82

100 LA4 81,1 4,9 14,8 5,3 2,0 2,3 0,0073 46,80,81

13801380

1420

13801385

13901390

1420

16801680

1720

16801685

16901690

1720

160 M4160 L4180 M4

88,689,490,0

22,129,936,2

7298

121

5,25,86,2

2,02,22,3

2,12,42,5

0,0340,0750,090

123135148

0,810,810,82

145514601460

176017601765

315 SM4315 MA4315 MC4315 MD4

93,694,594,895,3

200237287353

705848

10281285

6,56,26,26,5

2,62,52,52,5

2,62,52,52,6

2,102,102,503,10

780780859965

0,850,850,850,86

1488148514851485

1780178517851785

•••

7590

55

45

30

37

22

0,250,37

3

0,550,75

1,11,5

2,2

1115

18,5

110132160200

4

5,57,5

83100

60

50

33

40

24

0,250,37

3,2

0,550,75

1,21,6

2,3

121620

121158192240

4,4

5,87,9

112 M4

132 SA4132 MA4

84,2

85,787,4

8,3

11,414,8

0,83

0,820,84

26,8

36,549,4

5,7

6,56,7

2,4

2,02,2

2,7

2,62,75

0,0115

0,02380,0300

59,3

78,391,3

1425

14401450

1720

17401750

210270300

355 LX4355 LW4355 LY4

149014901490

95,395,595,5

0,860,870,87

370469521

134517291921

6,86,86,8

2,22,22,2

2,42,42,5

7,59,3

11,2

173019602180

210270300

179017901790

330400500

330400500

400 LX4400 LW4400 LY4

149014901490

179017901790

95,195,595,5

0,880,880,88

569687859

211325613201

6,86,87,2

2,32,31,2

2,22,32,5

15,818,820,7

288030303240

•••

•••

T4, T 135°C

250300330

355 LX4355 LW4355 LY4

149014901490

95,495,495,7

0,870,870,87

435522572

160119212113

6,86,86,8

2,22,22,2

2,12,42,5

7,59,3

11,2

173019602180

300350400

179017901790

375450560

450540630

400 LX4400 LW4400 LY4

149014901490

179017901790

95,595,595,5

0,880,880,88

644773962

240128813586

6,86,86,8

2,32,32,3

2,12,42,5

15,818,820,7

288030303240

T1 ÷ T3, T 150°C••••••

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.• Motor not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

Page 23: Motori Per Aree Pericolose

21

400V 50Hz / 440V 60HzEEx d IIB, EEx de IIB, IP65

1000/1200 min-1 = 6 poles - 50/60 Hz

280 S6280 M6

92,593,0

85102

438535

6,06,0

2,52,5

2,52,5

0,8501,075

479518

0,830,84

980980

11801180

250 M6 91,0 70 362 6,5 2,6 2,6 0,570 3420,84975 1175

225 M6 90,5 57 294 6,2 2,4 2,4 0,470 3090,84975 1175

200 LA6200 LB6

88,289,0

3643

182216

5,25,5

2,12,4

2,32,4

0,1700,220

185203

0,830,83

970972

11701170

180 L6 88,2 30,0 147 5,2 2,3 2,2 0,130 1650,82970 1170

80 MA680 MB6

65,268,0

1,11,6

3,85,6

3,63,9

1,92,1

2,252,4

0,00240,0028

21,323,3

0,720,73

132 SA6132 MA6132 MB6

80,181,082,0

7,19,1

12,4

30,240,255,3

5,55,76,2

2,12,32,5

2,42,62,8

0,03000,03800,0460

72,883,893,8

0,760,780,78

90 S690 L6

71,174,5

2,13,0

7,711,3

4,64,8

2,12,5

2,32,6

0,00380,0050

27,834,3

0,730,71

100 LA6 75,3 3,8 15,2 5,1 2,0 2,3 0,0100 47,30,75

112 M6 78,2 5,4 22,3 5,3 2,0 2,5 0,0150 56,30,75

930930

950950950

930930

940

940

11301130

115011501150

11301130

1140

1140

160 M6160 L6

86,088,0

15,422,0

74108

5,05,5

2,02,3

2,32,5

0,0870,110

131147

0,820,82

965967

11651165

315 SM6315 MA6315 MB6315 MC6315 MD6

94,094,094,093,394,8

139165201240283

726872106512781550

6,36,06,06,36,3

2,62,52,52,52,7

2,62,52,52,52,5

2,602,603,003,604,40

748748799889994

0,830,840,840,850,86

985985985985985

11851185118511851185

5466

44

36

2226

18

0,440,66

3,64,86,6

0,91,3

1,8

2,6

913,2

90108132158192

4555

37

30

18,522

15

0,370,55

34

5,5

0,751,1

1,5

2,2

7,511

7590

110132160

T1 ÷ T4, T 135°C

T1 ÷ T3, T 150°C200250280

355 LX6355 LW6355 LY6

990990990

95,095,095,0

0,860,860,86

354442493

192724092698

6,26,56,5

2,22,22,2

2,32,52,2

11,214,015,5

182020602190

240300330

119011901190

315355400

380420480

400 LX6400 LW6400 LY6

995995995

119011901190

95,095,095,0

0,870,870,87

551621699

302034043835

6,56,56,5

2,12,12,1

2,32,52,2

22,725,529,0

286030403300

160230250

355 LX6355 LW6355 LY6

990990990

95,095,095,0

0,860,860,86

283407440

154222162409

6,87,07,0

2,32,32,3

2,52,62,4

11,214,015,5

182020602190

160230250

119011901190

280315350

280315350

400 LX6400 LW6400 LY6

995995995

119411941194

95,095,095,0

0,870,870,87

490551612

268530203356

6,86,87,0

2,22,22,2

2,42,42,4

22,725,529,0

286030403300

T4, T 135°C

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.The motors shown on this page are not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

Page 24: Motori Per Aree Pericolose

22

400V 50Hz / 440V 60HzEEx d IIB, EEx de IIB, IP65

T1 ÷ T4, T 135°C

225 S8225 M8250 M8

89,090,091,0

404763

242288392

5,25,35,5

2,22,22,3

2,42,42,5

0,4200,5200,620

294326356

0,760,760,76

730730730

880880880

222636

18,52230

750/900 min-1 = 8 poles - 50/60 Hz

280 S8280 M8

92,593,0

7287

480584

6,06,0

2,52,5

2,52,5

1,0501,250

520553

0,800,80

735735

885885

200 L8 88,0 33 197 5,0 2,1 2,3 0,220 2160,75725 875

180 L8 86,7 24,4 145 4,5 2,0 2,2 0,160 1880,75725 875

80 MA880 MB8

53,056,3

0,71,0

2,63,5

3,53,5

2,02,0

1,81,8

0,00240,0027

21,822,8

0,720,67

90 S890 L8

59,363,3

1,42,0

5,27,6

3,53,5

2,02,0

1,81,8

0,00370,0050

27,335,8

0,660,64

100 LA8100 LB8

70,571,5

2,23,2

10,515,1

4,04,1

2,12,3

2,02,3

0,00930,0123

45,350,3

0,690,69

112 M8 73,0 4,2 20,5 4,4 2,4 2,4 0,0168 58,80,70

660690

675695

680695

700

810860

825845

830845

850

132 SA8132 MA8

75,077,0

5,77,4

29,640,6

4,44,6

2,02,1

2,22,3

0,03800,0460

78,892,8

0,740,76

710705

840845

315 SM8315 MA8315 MC8315 MD8315 ME8

93,593,894,494,594,6

105141166202243

709967

116014181702

6,56,06,26,26,2

2,32,12,22,22,2

2,42,22,32,32,3

2,802,803,504,004,30

776776886924993

0,810,820,830,830,83

740740740740740

890890890890890

4454

18

13,2

0,220,3

0,440,66

0,91,32

1,8

2,63,6

6690

108132158

3745

15

11

0,180,25

0,370,55

0,751,1

1,5

2,23

557590

110132

160 MA8160 MB8160 L8

81,582,484,7

9,713,017,3

547399

4,24,24,2

1,91,92,0

2,12,12,1

0,0800,0920,110

115123133

0,730,740,74

710720720

860870870

4,86,69

45,57,5

T1 ÷ T3, T 150°C160200220

355 LX8355 LW8355 LY8

740743744

94,895,395,6

0,840,840,85

290361391

206325682821

6,06,26,7

1,41,41,8

2,22,32,5

13,216,218,0

184020402170

180240270

890890893

250280315

300330380

400 LX8400 LW8400 LY8

745745745

893894894

95,695,595,6

0,800,800,80

472530595

320135864034

6,26,26,2

2,02,02,0

2,12,12,1

25,029,733,2

276029403200

T4, T 135°C150180200

355 LX8355 LW8355 LY8

740743744

94,895,395,6

0,840,840,85

272325356

193423112565

6,66,87,2

1,51,52,0

2,42,52,6

13,216,218,0

184020402170

150180200

890893894

230250280

230250280

400 LX8400 LW8400 LY8

745745745

895895895

95,695,595,6

0,810,820,83

429461510

294532013586

6,66,86,8

2,12,22,2

2,22,32,2

25,029,733,2

276029403200

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.The motors shown on this page are not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

Page 25: Motori Per Aree Pericolose

23

400V 50Hz / 440V 60HzEEx d IIB, EEx de IIB, IP65

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

600/720 min-1 = 10 poles - 50/60 Hz

315 MC10 1,2 2,5 4,70 856590 7109075315 MD10 1,1 2,3 5,50 924590 71011090

315 SM10315 MA10

1,41,4

1,62,6

4,004,00

776776

590590

710710

5466

4555

0,790,79

0,790,78

92,193,0

91,992,0

12131455

728889

4,84,5

5,05,0

149177

89111

T1 ÷ T3, T 150°C

110132160

355 LX10355 LW10355 LY10

590590590

94,094,595,0

0,780,780,78

217259312

177921342587

6,26,26,2

1,91,91,9

2,12,12,1

14,517,520,7

190021002230

132160180

710710710

180200225

210240270

400 LX10400 LW10400 LY10

595595595

713713713

95,095,095,0

0,780,780,78

351390439

288632073608

6,26,26,2

1,81,81,8

2,02,02,0

28,033,036,0

285029503220

T1 ÷ T3, T 150°C

T4, T 135°C100120140

355 LX10355 LW10355 LY10

590590590

94,094,595,0

0,780,780,78

197235273

161719402264

6,86,86,2

2,02,02,0

2,32,32,3

14,517,520,7

190021002230

100120140

710710710

160180200

160180200

400 LX10400 LW10400 LY10

595595595

715715715

95,095,095,0

0,780,780,78

312351390

256528863207

6,86,86,8

1,91,91,9

2,22,22,2

28,033,036,0

285029503220

37455575

315 SM12315 MA12315 MC12315 MD12

490490490490

0,770,760,770,77

7694

112153

720876

10711460

4,84,85,24,3

1,51,51,41,2

2,42,42,52,1

4,004,004,705,50

776776856924

500/600 min-1 = 12 poles - 50/60 Hz90,790,792,092,0

45546690

590590590590

T1 ÷ T3, T 150°C

90110132

355 LX12355 LW12355 LY12

490491491

93,093,593,5

0,760,760,77

184224265

175221372565

5,75,75,8

1,41,41,5

2,72,72,8

14,517,520,7

190021002230

110132160

590590590

160180200

180210240

400 LX12400 LW12400 LY12

495495495

583594594

94,094,594,5

0,780,780,78

315353392

308434693855

6,06,06,0

1,61,61,6

1,91,91,9

28,033,036,0

285029503220

T1 ÷ T3, T 150°C

80100110

355 LX12355 LW12355 LY12

490491491

93,093,593,5

0,760,760,77

164203221

155819432137

6,26,26,4

1,51,51,6

2,82,82,8

14,517,520,7

190021002230

80100110

590590590

140160180

140160180

400 LX12400 LW12400 LY12

495495495

595595595

94,094,594,5

0,780,780,78

276314353

269830843469

6,66,66,0

1,71,71,7

2,12,12,1

28,033,036,0

285029503220

T4, T 135°C

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.The motors shown on this page are not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

Page 26: Motori Per Aree Pericolose

24

400V 50Hz / 440V 60Hz

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.The motors shown on this page are not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

EEx d IIB, EEx de IIB, IP65

0,250,37

0,550,75

1,11,5

2,23,0

5,57,5

1115

18,522

27

3340,5

50

6175

110115138170

71 MA471 MB4

80 MA480 MB4

90 S490 L4

100 LA4100 LB4

132 SA4132 MA4

160 M4160 L4

180 M4180 L4

200 L4

225 S4225 M4

250 M4

280 S4280 M4

315 SM4315 MA4315 MC4315 MD4

13801380

13801385

13901390

14201420

14401450

14551455

14601465

1470

14751475

1475

14851485

1486148514851485

67,669,5

72,073,0

76,579,1

81,183,0

85,787,4

8787

8890

90

9292

92

93,594

94949494

0,81,1

1,52,0

2,63,4

4,96,4

11,414,8

22,530,7

37,541,5

52

6277

90

111132

204210252307

1,732,6

3,85,2

7,610,3

14,820,2

36,549,4

7298

121143

175

213262

323

392482

7067398871092

3,83,8

4,64,75

4,54,7

5,35,5

6,56,7

5,25,8

6,26,3

6,6

6,76,7

6,4

7,77,7

6,96,56,56,8

2,32,5

2,62,8

2,52,7

2,02,1

2,02,2

2,02,2

2,32,4

2,4

2,42,4

2,4

2,72,7

2,82,62,62,7

2,32,5

2,42,5

2,42,5

2,32,5

2,62,75

2,12,4

2,52,5

2,8

2,82,8

2,5

2,62,6

2,82,62,62,6

0,00050,0006

0,00130,0016

0,00330,0040

0,00730,0090

0,02380,0300

0,0630,075

0,0900,110

0,180

0,3200,410

0,520

0,8851,060

2,1002,1002,5003,100

16,317,3

21,322,8

27,331,8

46,850,8

78,391,3

123135

148177

205

302332

370

525584

780780859965

1500/1800 min-1 = 4 poles - 50/60 Hz0,680,68

0,740,74

0,790,82

0,810,81

0,820,84

0,810,81

0,810,85

0,83

0,830,83

0,87

0,850,87

0,830,840,840,85

0,250,37

0,550,75

1,11,5

2,23,0

5,57,5

12,517

2126

32

3846,5

57,5

7086

110132158195

17001710

16851720

17201705

17251730

17551760

17551755

17601765

1770

17751775

1775

17801780

1790178517851785

T5, T 100°C

T5, T 100°C0,370,55

0,751,1

1,52,2

3,0

5,57,59,0

1115

18,5

22

3037

40,5

50

7084

110120145185

71 MA271 MB2

80 MA280 MB2

90 S290 L2

100 LA2

132 SA2132 SB2132 MB2

160 MA2160 MB2160 L2

180 M2

200 LA2200 LB2

225 M2

250 M2

280 S2280 M2

315 SM2315 MA2315 MC2315 MD2

27302730

28002830

28102850

2900

290529052915

290029102925

2930

29452950

2960

2955

29552955

2975297029752980

69,572,3

74,177,5

78,781,1

83,0

85,787,087,2

868789

88,5

9091

92

90

9292

92,592

93,593,5

1,01,4

1,82,4

3,34,7

6,2

10,914,317,1

22,229,636,2

46,7

5568

72

93

126150

205219261329

1,31,9

2,63,7

5,17,4

9,9

18,124,729,5

364960

72

97120

131

161

226271

353385465592

4,44,6

5,65,9

6,16,4

6,8

7,57,87,8

6,26,46,8

6,8

6,76,5

6,7

6,7

6,87,2

7,56,86,86,8

2,83,0

2,42,6

2,52,7

2,1

2,52,62,9

2,12,22,4

2,4

2,32,4

2,4

2,4

2,32,3

2,42,52,62,6

--

2,32,6

2,62,9

2,6

2,83,23,6

2,83,03,0

3,0

2,93,0

3,0

3,0

2,72,7

2,72,62,62,6

0,00040,0005

0,00080,0010

0,00160,0022

0,0050

0,01600,01900,0230

0,0300,0350,040

0,048

0,1650,180

0,225

0,250

0,3500,416

0,9500,9501,1201,300

15,317,3

20,822,8

26,832,3

48,3

75,881,891,8

115129143

154

189209

304

336

484527

760760827887

3000/3600 min-1 = 2 poles - 50/60 Hz0,780,79

0,830,84

0,840,83

0,84

0,850,870,87

0,830,840,83

0,77

0,870,87

0,88

0,86

0,870,88

0,840,860,860,87

0,370,55

0,751,1

1,52,2

3,0

5,57,59,0

12,51721

25

3642,5

46,5

57,5

80,596,5

125138160213

33503360

34303470

34603480

3510

349035103520

350035103525

3530

35453550

3560

3555

35603560

3570357035753580

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

Page 27: Motori Per Aree Pericolose

25

400V 50Hz / 440V 60HzEEx d IIB, EEx de IIB, IP65

0,370,55

0,75

1,5

3,0

7,511

13,5

17,020

26

32

3645

707590

105128

80 MA680 MB6

90 S6

100 LA6

132 SA6

160 M6160 L6

180 L6

200 LA6200 LB6

225 M6

250 M6

280 S6280 M6

315 SM6315 MA6315 MB6315 MC6315 MD6

930930

930

940

950

965975

975

970975

980

975

988988

987985985985985

65,268,0

71,1

75,3

80,1

8686,5

88

8889

90

90

9292

9494949494

1,11,6

2,1

3,8

7,1

15,422,4

27

33,639,1

52

62

6986

130137165192232

3,85,6

7,7

15,2

30,2

74108

132

167196

253

313

348435

677726872

10171240

3,63,9

4,6

5,1

5,5

5,05,5

5,2

5,56,0

6,5

6,5

6,06,0

6,96,36,36,66,6

1,92,1

2,1

2,0

2,1

2,02,3

2,3

2,22,5

2,6

2,6

2,52,5

2,92,62,62,62,8

2,252,4

2,3

2,3

2,4

2,32,5

2,2

2,32,5

2,7

2,6

2,52,5

2,92,62,62,62,6

0,00240,0028

0,0038

0,0100

0,0300

0,0870,110

0,130

0,1700,220

0,470

0,570

0,8501,075

2,6002,6003,0003,6004,400

21,323,3

27,8

47,3

72,8

131147

165

185203

309

342

479518

748748799889994

1000/1200 min-1 = 6 poles - 50/60 Hz0,720,73

0,73

0,75

0,76

0,820,82

0,82

0,830,83

0,81

0,83

0,820,82

0,830,840,840,840,85

0,370,55

0,75

1,5

3,0

913

15,5

19,523

30

36,5

41,551,5

8086

103120147

11301140

1120

1140

1150

11651175

1175

11701175

1180

1185

11801180

11851185118511851185

T5, T 100°C

0,180,25

0,370,55

0,751,1

2,2

4,05,57,0

10,0

13,5

17,020,5

28

3441

60658095

112

80 MA880 MB8

90 S890 L8

100 LA8100 LB8

132 SA8

160 MA8160 MB8160 L8

180 L8

200 L8

225 S8225 M8

250 M8

280 S8280 M8

315 SM8315 MA8315 MC8315 MD8315 ME8

660690

675695

680695

710

720720725

728

728

728730

730

737737

741740740740740

53,056,3

59,363,3

70,571,5

75,0

818283

86

87

8990

91

9292

9393,5949494

0,71,0

1,42,0

2,23,2

5,7

9,813,116,7

22,7

29,9

36,344,5

59

6882

118126152180213

2,63,5

5,27,6

10,515,1

29,6

537392

131

177

227268

366

433527

644838

103112251444

3,53,5

3,53,5

4,04,1

4,4

4,24,24,2

4,5

5,0

5,35,7

5,7

6,06,0

6,86,36,56,56,5

2,02,0

2,02,0

2,12,3

2,0

1,91,92,0

2,0

2,1

2,32,4

2,4

2,52,5

2,42,22,32,32,3

1,81,8

1,81,8

2,02,3

2,2

2,12,12,1

2,2

2,3

2,42,5

2,5

2,72,7

2,52,32,42,42,4

0,00240,0028

0,00380,0050

0,00930,0123

0,0380

0,0800,0920,110

0,160

0,220

0,4200,520

0,620

1,0501,250

2,82,83,54,04,3

21,822,8

27,335,8

45,350,3

78,8

115123133

188

216

294326

356

520553

776776886924993

750/900 min-1 = 8 poles - 50/60 Hz0,720,67

0,660,64

0,690,69

0,74

0,730,740,73

0,74

0,75

0,760,74

0,76

0,790,79

0,790,800,810,810,81

0,180,25

0,370,55

0,751,1

2,2

4,56,08,0

12,0

16,0

19,523,5

32

3947

6574,591,5109128

820835

840850

865865

860

870870875

880

880

880880

880

885885

891890890890890

T5, T 100°C

Is = Starting current, Ts = Starting torque, TMAX = Breakdown torque.Detailed data for 440V/60Hz on request.The motors shown on this page are not multivoltage. Output values at 440V/60Hz refer to motors with dedicated winding.

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

Jkgm2

Approx.kg

kW BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.Ts / Tn

SPEED

n

EFFICIENCY

ηη

%RATED

CURRENT

IA

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

PERFORMANCE AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In50Hz

60Hz

50Hz

60Hz

400V 50Hz

1/min

Page 28: Motori Per Aree Pericolose

26

1,1

1

0,9

Kc 0,8

0,7

0,6

0,55

71 - 132 IC 411

f [Hz]

Curve 2: 2 poles - T4, T135°C

10 15 20 25 30 35 40 45 50 55 60

160 - 400 IC 416160 - 400 IC 411

1,1

1

0,9

Kc 0,8

0,7

0,6

0,5105 15 20 25 30 35 40 45 50 55 60 65 70 75

71 - 400 IC 411

f [Hz]

Curve 1: 2 poles - T3, T150°C

160 - 400 IC 416

2 poles

Table 1

0,370,55

0,751,1

1,52,2

2,9

4

5,57,59

1115

18,5

22

3037

45

55

7590

110132160185

220270315

355430530

1: Not available with EEx de type of protection-: Not available

71 MA2 1

71 MB2 1

80 MA2 1

80 MB2 1

90 S2 1

90 L2 1

100 LA2

112 M2

132 SA2132 SB2132 MB2

160 MA2160 MB2160 L2

180 M2

200 LA2200 LB2

225 M2

250 M2

280 S2280 M2

315 SM2315 MA2315 MC2315 MD2

355 LX2355 LW2355 LY2

400 LX2400 LW2400 LY2

1,291,92

2,63,7

5,17,4

9,5

13,1

18,024,629,5

364960

72

97120

145

177

242290

353424514593

705865

1009

113813781698

0,991,39

1,762,4

3,34,7

6,0

8,0

10,914,317,1

21,929,037

42

5467

80

98

133157

194235281324

373454522

596718885

0,260,39

0,530,77

1,051,54

1,89

2,6

3,95,36,3

8,011,012,2

14,6

21,924,3

33

40

5059

8087105120

146176205

231280345

0,911,35

1,792,6

3,65,2

6,2

8,5

12,617,220,6

26,33640

48

7179

106

130

160191

258279337385

468562656

7398961104

0,690,97

1,231,71

2,33,3

3,9

5,2

7,610,012,0

16,021,024,0

28,0

3944

58

72

88103

141155185211

248295339

387467575

0,260,39

0,530,77

1,051,54

1,89

2,6

3,95,36,3

8,011,012,2

14,6

21,924,3

33

40

5059

8087

105120

146176205

231280345

0,911,35

1,792,6

3,65,2

6,2

8,5

12,617,220,6

26,33640

48

7179

106

130

160191

258279337385

468562656

739896

1104

0,690,97

1,231,71

2,33,3

3,9

5,2

7,610,012,0

16,021,024,0

28,0

3944

58

72

88103

141155185211

248295339

387467575

--

--

--

-

-

---

1115

18,5

22

3037

45

55

7590

110132160185

220270315

355430530

--

--

--

-

-

---

364960

72

97120

145

177

242290

353424514593

7058651009

113813781698

--

--

--

-

-

---

21,929,037

42

5467

80

98

133157

194235281324

373454522

596718885

--

--

--

-

-

---

9,012,315,2

18,0

24,630

37

45

6174

90108131152

180221258

291352434

--

--

--

-

-

---

17,923,830

34

4455

65

80

109128

158192230265

306372427

488588725

--

--

--

-

-

---

29,54049

59

8098

119

145

198238

289348421486

577709827

93211291391

400V 50HzSUPPLY FROM FREQUENCY CONVERTEREEx d IIB T3, EEx de IIB T3, EEx d IIC T3, EEx de IIC T3, IP65 T150°C

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 60

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 60

CONSTANT TORQUE10 ÷ 50

Page 29: Motori Per Aree Pericolose

400V 50Hz

In case of operating frequencies out from the ranges shown in the table above, please proceed as follow.

Quadratic torqueIf fmax (maximum supply frequency) is ≤50Hz and the minimum supply frequency fmin is ≥5Hz, the available outputs remain those shown in tables 1 and 2 respectively fortemperature class T3 (or maximum surface temperature T150°C) or T4 (T135°C).

Constant torque1. By applying to the curve 1 or 2 given in the previous page, and depending on the class of temperature or the maximum surface temperature, calculate the Kc value

relate to frequency variation’s limits, and take into consideration the lower only in case of IC411, or that one at the max frequency as for IC416.2. In order to get the Tm value (maximum torque of the motor), multiply the Kc value by the Tn value of the quadratic torque’s column within the class of temperature

and/or max surface temperature (table 1 or table 2).3. The following formulas are to be applied to calculate the nominal power Pn and current In at 400V 50Hz.

P’n = Pn xTm

Tn

[kW] I’n = In xTm

Tn

[A]

27

SUPPLY FROM FREQUENCY CONVERTEREEx d IIB T4, EEx de IIB T4, IP65 T135°C

0,370,55

0,751,1

1,52,2

2,7

3,6

5,57,59

1115

16,7

20

3033

45

55

6881

110119144160

200230250

315380450

71 MA2 1

71 MB2 1

80 MA2 1

80 MB2 1

90 S2 1

90 L2 1

100 LA2

112 M2

132 SA2132 SB2132 MB2

160 MA2160 MB2160 L2

180 M2

200 LA2200 LB2

225 M2

250 M2

280 S2280 M2

315 SM2315 MA2315 MC2315 MD2

355 LX2355 LW2355 LY2

400 LX2400 LW2400 LY2

1,291,92

2,63,7

5,17,4

8,9

11,8

18,024,629,5

364955

65

97108

145

177

219261

353383462513

641737801

100912181442

0,991,39

1,762,4

3,34,7

5,6

7,2

10,914,317,1

21,929,033

38

5460

80

98

121141

194212253280

339387414

529634751

0,260,39

0,530,77

1,051,54

1,89

2,5

3,95,36,3

8,011,012,2

14,6

21,924,3

33

40

5059

8087105117

146168183

230277329

0,911,35

1,792,6

3,65,2

6,2

8,3

12,617,220,6

26,33640

48

7179

106

130

160191

258279337385

468538585

737889

1053

0,690,97

1,231,71

2,33,3

3,9

5,1

7,610,012,0

16,021,024,0

28,0

3944

58

72

88103

141155185211

248282302

386463548

0,260,39

0,530,77

1,051,54

1,89

2,5

3,95,36,3

8,011,012,2

14,6

21,924,3

33

40

5059

8087

105120

146168183

230277329

0,911,35

1,792,6

3,65,2

6,2

8,3

12,617,220,6

26,33640

48

7179

106

130

160191

258279337385

468538585

737889

1053

0,690,97

1,231,71

2,33,3

3,9

5,1

7,610,012,0

16,021,024,0

28,0

3944

58

72

88103

141155185211

248282302

386463548

--

--

--

-

-

---

1115

16,7

20

3033

45

55

6881

110119144160

200230250

315380450

--

--

--

-

-

---

364955

65

97108

145

177

219261

353383462513

641737801

100912181442

--

--

--

-

-

---

21,929,033

38

5460

80

98

121141

194212253280

339387414

529634751

--

--

--

-

-

---

9,012,313,7

16,4

24,627,3

37

45

5666

9098

118131

164189205

258312369

--

--

--

-

-

---

17,923,821,1

31

4449

65

80

99116

159174208230

278317339

434520616

--

--

--

-

-

---

29,54045

53

8089

119

145

180214

290314379420

526604657

8289991182

2 poles

Table 21: Not available with EEx de type of protection-: Not available

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 60

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 60

CONSTANT TORQUE10 ÷ 50

Page 30: Motori Per Aree Pericolose

400V 50Hz

1,1

1

0,9

Kc 0,8

0,7

0,6

0,55 15 25 35 45 55 65 75 85 95

71 - 400 IC411

f [Hz]

Curve 3: 4 poles - T3, T150°C

160 - 400 IC416

1,1

1

0,9

Kc 0,8

0,7

0,6

0,571 - 132 IC411

f [Hz]

Curve 4: 4 poles - T4, T135°C

160 - 400 IC411

105 15 20 25 30 35 40 45 50 55 75 80 95 100908560 65 70

160 - 400 IC416

SUPPLY FROM FREQUENCY CONVERTEREEx d IIB T3, EEx de IIB T3, EEx d IIC T3, EEx de IIC T3, IP65 T150°C

For maximum frequency between 75Hz and 100Hz, please contact MarelliMotori.

Table 31: Not available with EEx de type of protection-: Not available

0,250,37

0,550,75

1,11,5

2,23

4

5,57,5

1115

17,622

30

3745

55

7590

110132160185

240285315

355430530

71 MA4 1

71 MB4 1

80 MA4 1

80 MB4 1

90 S4 1

90 L4 1

100 LA4100 LB4

112 M4

132 SA4132 MA4

160 M4160 L4

180 M4180 L4

200 L4

225 S4225 M4

250 M4

280 S4280 M4

315 SM4315 MA4315 MC4315 MD4

355 LX4355 LW4355 LY4

400 LX4400 LW4400 LY4

1,732,6

3,85,2

7,610,3

14,820,2

26,8

3649

7298

115143

195

240291

356

484581

706849

10291190

153818272019

227527563397

0,781,13

1,492,0

2,63,3

4,86,4

8,3

11,314,7

22,129,9

3442

56

6782

98

134157

200237287326

417496546

610739910

0,180,26

0,390,53

0,771,05

1,542,1

2,8

3,95,3

8,09,9

12,216,1

21,9

27,033

37

5566

7396105120

156185205

231280345

1,211,79

2,73,6

5,37,2

10,414,1

18,8

25,535

5364

80105

142

175213

236

353424

468620676773

100011871312

147917912208

0,550,79

1,041,40

1,842,3

3,14,5

5,8

7,910,3

16,220

2431

41

4960

65

98115

132173188212

271322355

396480592

0,150,22

0,330,45

0,660,90

1,321,8

2,4

3,34,5

6,68,1

10,013,2

18,0

22,227,0

30

4554

607986

111

144171189

213258318

1,041,54

2,303,1

4,56,2

8,912,1

16,1

21,929,6

43,053

6686

117

144174

194

290348

385509556714

92310961211

136516542038

0,470,68

0,891,20

1,582,0

2,93,9

5,0

6,88,8

13,316,1

19,625,1

34

4049

54

8194

109142155195

250297328

366443546

--

--

--

--

-

--

1115

17,622

30

3745

55

7590

110132160185

240285315

355430530

--

--

--

--

-

--

7298

115143

195

240291

356

484581

706849

10291190

153818272019

227527563397

--

--

--

--

-

--

22,129,9

3442

56

6782

98

134157

200237287326

417496546

610739910

--

--

--

--

-

--

6,69,0

10,613,2

18,0

22,227,0

33

4554

667996

111

144171189

213258318

--

--

--

--

-

--

13,317,9

20,725,1

34

4049

59

8194

120142172195

250297328

366443546

--

--

--

--

-

--

4359

6986

117

144175

214

290348

424509617714

92310961211

136516542038

4 poles

28

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

Page 31: Motori Per Aree Pericolose

400V 50Hz

P’n = Pn xTm

Tn

[kW] I’n = In xTm

Tn

[A]

SUPPLY FROM FREQUENCY CONVERTEREEx d IIB T4, EEx de IIB T4, IP65 T135°C

4 poles0,250,37

0,550,75

1,11,5

2,23

4

5,57,5

1113,5

16,722

30

3745

50

7590

110132144160

200250270

315380450

71 MA4 1

71 MB4 1

80 MA4 1

80 MB4 1

90 S4 1

90 L4 1

100 LA4100 LB4

112 M4

132 SA4132 MA4

160 M4160 L4

180 M4180 L4

200 L4

225 S4225 M4

250 M4

280 S4280 M4

315 SM4315 MA4315 MC4315 MD4

355 LX4355 LW4355 LY4

400 LX4400 LW4400 LY4

1,732,6

3,85,2

7,610,3

14,820,2

26,8

3649

7288

109143

195

240291

324

484581

7068499261029

128216021730

201924352884

0,781,13

1,492,0

2,63,3

4,86,4

8,3

11,314,7

22,126,9

3342

56

6782

89

134157

200237258282

348435468

541653773

0,180,26

0,390,53

0,771,05

1,542,1

2,8

3,95,3

8,09,9

12,216,1

21,9

27,033

37

5566

7396105117

146183197

230277329

1,211,79

2,73,6

5,37,2

10,414,1

18,8

25,535

5364

80105

142

175213

236

353424

468620676751

93611701263

147417782105

0,550,79

1,041,40

1,842,3

3,44,5

5,8

7,910,3

16,220

2431

41

4960

65

98115

132173188206

254317342

395476564

0,150,22

0,330,45

0,660,90

1,321,80

2,4

3,34,5

6,68,1

10,013,2

18,0

22,227,0

30

4554

60798696

120150162

189228270

1,041,54

2,33,1

4,56,2

8,912,1

16,1

21,929,6

4353

6686

117

144174

194

290348

385509556617

769961

1038

121114611730

0,470,68

0,891,20

1,582,0

2,93,9

5,0

6,88,8

13,316,1

19,625,1

34

4049

54

8194

109142155169

209261281

325392464

--

--

--

--

-

--

1113,5

16,722

30

3745

50

7590

100132144160

200250270

315380450

--

--

--

--

-

--

7288

109143

195

240291

324

484581

706849926

1029

128216021730

201924352884

--

--

--

--

-

--

22,126,9

3342

56

6782

89

134157

200237258282

348435468

541653773

--

--

--

--

-

--

6,68,1

10,013,2

18,0

22,227,0

30

4554

60798696

120150162

189228270

--

--

--

--

-

--

13,316,1

19,625,1

34

4049

54

8194

109142155169

209261281

325392464

--

--

--

--

-

--

4353

6686

117

144175

194

290348

385509556617

7699611038

121114611730

29

Table 41: Not available with EEx de type of protection-: Not available

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

In case of operating frequencies out from the ranges shown in the table above, please proceed as follow.

Quadratic torqueIf fmax (maximum supply frequency) is ≤50Hz and the minimum supply frequency fmin is ≥5Hz, the available outputs remain those shown in tables 3 and 4 respectively fortemperature class T3 (or maximum surface temperature T150°C) or T4 (T135°C).

Constant torque1. By applying to the curve 3 or 4 given in the previous page, and depending on the class of temperature or the maximum surface temperature, calculate the Kc value

relate to frequency variation’s limits, and take into consideration the lower only in case of IC411, or that one at the max frequency as for IC416.2. In order to get the Tm value (maximum torque of the motor), multiply the Kc value by the Tn value of the quadratic torque’s column within the class of temperature

and/or max surface temperature (table 3 or table 4).3. The following formulas are to be applied to calculate the nominal power Pn and current In at 400V 50Hz.

Page 32: Motori Per Aree Pericolose

30

400V 50HzSUPPLY FROM FREQUENCY CONVERTEREEx d IIB T3, EEx de IIB T3, EEx d IIC T3, EEx de IIC T3, IP65 T150°C

For maximum frequency between 75Hz and 100Hz, please contact MarelliMotori.

0,370,55

0,751,1

1,5

2,2

33,85,2

7,511

15

18,522

30

37

4555

7190

110132152

190240270

300340380

80 MA6 1

80 MB6 1

90 S6 1

90 L6 1

100 LA6

112 M6

132 SA6132 MA6132 MB6

160 M6160 L6

180 L6

200 LA6200 LB6

225 M6

250 M6

280 S6280 M6

315 SM6315 MA6315 MB6315 MC6315 MD6

355 LX6355 LW6355 LY6

400 LX6400 LW6400 LY6

3,85,6

7,711,3

15,2

22,3

303852

71109

148

182216

294

362

438536

688873

106612801474

183323152604

287932633647

1,141,60

2,13,0

3,8

5,4

7,18,711,7

15,422,0

29,9

3643

57

70

85102

131165201240269

336424477

524594664

0,260,39

0,530,77

1,05

1,54

1,892,53,5

5,58,0

11,0

13,114,6

21,9

27,0

3340

49668096105

124156176

195221247

2,74,0

5,47,9

10,7

15,6

19,025,335

5479

108

129143

214

265

320391

4746377789341019

119115051693

187121212371

0,801,12

1,462,1

2,7

3,8

4,55,87,9

11,216,1

21,9

25,928,5

42

51

6274

90120147175186

218276310

341386431

0,220,33

0,450,66

0,90

1,32

1,802,33,1

4,56,6

9,0

11,113,2

18,0

22,2

27,033

4354667991

114144162

180204228

2,33,4

4,66,8

9,1

13,4

18,122,931

4565

89

109130

176

217

263322

413524640768884

110013891563

172819582188

0,680,96

1,251,80

2,3

3,2

4,35,27,0

9,213,2

18,0

21,925,8

34

42

5161

7999121144161

201254286

314356398

--

--

-

-

---

7,511

15

18,522

30

37

4555

7190

110132152

190240270

300340380

--

--

-

-

---

71109

148

182216

294

362

438536

688873

106612801474

183323152604

287932633647

--

--

-

-

---

15,422,0

29,9

36,043

57

70

85102

131165201240269

336424477

524594664

--

--

-

-

---

4,56,6

9,0

11,113,2

18,0

22,2

27,033,0

4354667991

114144162

180204228

--

--

-

-

---

9,213,2

18,0

21,925,8

34,0

42

5161

7999121144161

201254286

314356398

--

--

-

-

---

4565

89

109130

176

217

263322

413524640768884

110013891563

172819582188

6 poles

1,1

1

0,9

Kc 0,8

0,7

0,6

0,55 15 25 35 45 55 65 75 85 95

71 - 400 IC411

f [Hz]

Curve 5: 6 poles - T3, T150°C

160 - 400 IC416

1,1

1

0,9

Kc 0,8

0,7

0,6

0,571 - 132 IC411

f [Hz]

Curve 6: 6 poles - T4, T135°C

160 - 400 IC411

105 15 20 25 30 35 40 45 50 55 75 80 95 100908560 65 70

160 - 400 IC416

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

Table 51: Not available with EEx de type of protection-: Not available

Page 33: Motori Per Aree Pericolose

31

400V 50Hz

P’n = Pn xTm

Tn

[kW] I’n = In xTm

Tn

[A]

SUPPLY FROM FREQUENCY CONVERTEREEx d IIB T4, EEx de IIB T4, IP65 T135°C

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

0,370,55

0,751,1

1,5

2,2

2,73,65

7,511

15

1820

30

37

4555

6790

110132144

160210230

250280315

80 MA6 1

80 MB6 1

90 S6 1

90 L6 1

100 LA6

112 M6

132 SA6132 MA6132 MB6

160 M6160 L6

180 L6

200 LA6200 LB6

225 M6

250 M6

280 S6280 M6

315 SM6315 MA6315 MB6315 MC6315 MD6

355 LX6355 LW6355 LY6

400 LX6400 LW6400 LY6

3,85,6

7,711,3

15,2

22,3

27,03650

71109

148

177196

294

362

438536

650873

106612801396

154320262219

239926873023

1,141,60

2,13,0

3,8

5,4

6,48,211,3

15,422,0

29,9

3539

57

70

85102

124165201240255

283371406

437489550

0,260,39

0,530,77

1,05

1,54

1,892,53,5

5,58,0

11,0

13,114,6

21,9

27,0

3340

49668096105

117153168

183204230

2,74,0

5,47,9

10,7

15,6

19,025,335

5479

108

129143

214

265

320391

4746377789341019

112714791620

175219622207

0,801,12

1,462,1

2,7

3,8

4,55,87,9

11,216,1

21,9

25,928,5

42

51

6274

90120147175186

206271297

319357402

0,220,33

0,450,66

0,90

1,32

1,622,23,0

4,56,6

9,0

10,812,0

18,0

22,2

27,033

4054667986

96126138

150168189

2,33,4

4,66,8

9,1

13,4

16,321,730

4565

89

106118

176

217

263322

390524640768838

92612151331

144016121814

0,680,96

1,251,80

2,3

3,2

3,84,96,8

9,213,2

18,0

21,323,4

34

42

5161

7499

121144153

160210230

250280315

--

--

-

-

---

7,511

15

1820

30

37

4555

6790

110132144

160210230

250280315

--

--

-

-

---

71109

148

177196

294

362

438536

650873

106612801396

154320262219

239926873023

--

--

-

-

---

15,422,0

29,9

3539

57

70

85102

124165201240255

283371406

437489550

--

--

-

-

---

4,56,6

9,0

10,812,0

18,0

22,2

27,033

4054667986

96126138

150168189

--

--

-

-

---

9,213,2

18,0

21,323,4

34

42

5161

7499121144153

160210230

250280315

--

--

-

-

---

4565

89

106118

176

217

263322

390524640768838

92612151331

144016121814

6 poles

Table 61: Not available with EEx de type of protection-: Not available

In case of operating frequencies out from the ranges shown in the table above, please proceed as follow.

Quadratic torqueIf fmax (maximum supply frequency) is ≤50Hz and the minimum supply frequency fmin is ≥5Hz, the available outputs remain those shown in tables 5 and 6 respectively fortemperature class T3 (or maximum surface temperature T150°C) or T4 (T135°C).

Constant torque1. By applying to the curve 5 or 6 given in the previous page, and depending on the class of temperature or the maximum surface temperature, calculate the Kc value

relate to frequency variation’s limits, and take into consideration the lower only in case of IC411, or that one at the max frequency as for IC416.2. In order to get the Tm value (maximum torque of the motor), multiply the Kc value by the Tn value of the quadratic torque’s column within the class of temperature

and/or max surface temperature (table 5 or table 6).3. The following formulas are to be applied to calculate the nominal power Pn and current In at 400V 50Hz.

Page 34: Motori Per Aree Pericolose

32

SUPPLY FROM FREQUENCY CONVERTEREEx d IIB T3, EEx de IIB T3, EEx d IIC T3, EEx de IIC T3, IP65 T150°C 400V 50Hz

0,180,25

0,370,55

0,751,1

1,4

2,23

45,57,5

11

15

18,522

30

3745

558396

110132

160200220

240270300

80 MA8 1

80 MB8 1

90 S8 1

90 L8 1

100 LA8100 LB8

112 M8

132 SA8132 MA8

160 MA8160 MB8160 L8

180 L8

200 L8

225 M8225 L8

250 M8

280 S8280 M8

315 SM8315 MA8315 MC8315 MD8315 ME8

355 LX8355 LW8355 LY8

400 LX8400 LW8400 LY8

2,63,5

5,27,6

10,515,1

19,1

29,641

547399

145

198

242288

392

481585

7101071123914191703

206525702824

307634613845

0,680,96

1,362,0

2,23,2

4,0

5,77,4

9,713,017,3

24,4

33

3946

63

7287

105156177202243

290361395

453510566

0,130,18

0,260,39

0,530,77

0,95

1,542,1

2,94,05,5

8,0

11,0

13,116,1

21,9

27,033

4055668088

110130143

156176195

1,822,4

3,75,3

7,410,6

12,9

20,728,5

395373

106

144

172210

286

351427

51870784810361130

141316711835

200022502499

0,480,67

0,961,37

1,562,3

2,7

4,05,2

7,19,512,6

18

24

2834

46

5364

77103121148161

198234257

294332368

0,110,15

0,220,33

0,450,66

0,81

1,321,80

2,43,34,5

6,6

9,0

10,813,2

18,0

22,227,0

3345546672

90102114

120138150

1,562,1

3,14,5

6,39,1

11,0

17,824,4

324460

87

119

141173

235

288351

426581697852929

116113111463

153817691923

0,410,57

0,821,18

1,341,93

2,4

3,44,4

5,87,8

10,4

14,7

19,7

23,727,9

38

4352

6393

106121146

174216237

272306340

--

--

--

-

--

45,57,5

11

15

18,522

30

3745

558396

110132

160200220

240270300

--

--

--

-

--

547399

145

198

242288

392

481585

7101071123914191703

206525702824

307634613845

--

--

--

-

--

9,713,017,3

24,4

33

3946

63

7287

105156177202243

290361395

453510566

--

--

--

-

--

2,43,34,5

6,6

9,0

10,813,2

18,0

22,227,0

3345546672

90102114

120138150

--

--

--

-

--

5,87,810,4

14,7

19,7

23,727,9

38

4352

6393106121146

174216237

272306340

--

--

--

-

--

324460

87

119

141173

235

288351

426581697852929

116113111463

153817691923

8 poles

1,1

1

0,9

Kc 0,8

0,7

0,6

0,55 15 25 35 45 55 65 75 85 95

71 - 400 IC411

f [Hz]

Curve 7: 8 poles - T3, T150°C

160 - 400 IC416

1,1

1

0,9

Kc 0,8

0,7

0,6

0,571 - 132 IC411

f [Hz]

Curve 8: 8 poles - T4, T135°C

160 - 400 IC411

105 15 20 25 30 35 40 45 50 55 75 80 95 100908560 65 70

160 - 400 IC416

For maximum frequency between 75Hz and 100Hz, please contact MarelliMotori.

Table 71: Not available with EEx de type of protection-: Not available

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

Page 35: Motori Per Aree Pericolose

33

400V 50HzSUPPLY FROM FREQUENCY CONVERTEREEx d IIB T4, EEx de IIB T4, IP65 T135°C

P’n = Pn xTm

Tn

[kW] I’n = In xTm

Tn

[A]

Table 8

0,180,25

0,370,55

0,751,1

1,35

2,23

45,57,5

11

15

1822

30

3745

557590

110120

150170190

200230250

80 MA8 1

80 MB8 1

90 S8 1

90 L8 1

100 LA8100 LB8

112 M8

132 SA8132 MA8

160 MA8160 MB8160 L8

180 L8

200 L8

225 M8225 L8

250 M8

280 S8280 M8

315 SM8315 MA8315 MC8315 MD8315 ME8

355 LX8355 LW8355 LY8

400 LX8400 LW8400 LY8

2,63,5

5,27,6

10,515,1

18,4

29,641

547399

145

198

235288

392

481585

710968

116114191549

193621852439

256429483204

0,680,96

1,362,0

2,23,2

3,8

5,77,4

9,713,017,3

24,4

33

3846

63

7287

105141166202221

272307342

377435472

0,130,18

0,260,39

0,530,77

0,95

1,542,1

2,94,05,5

8,0

11,0

13,116,1

21,9

27,033

4055668088

110124139

146168183

1,822,4

3,75,3

7,410,6

12,9

20,728,5

395373

106

144

172210

286

351427

51870784810361130

141315951780

187121522339

0,480,67

0,961,37

1,562,3

2,7

4,05,2

7,19,512,6

17,8

23,9

28,034

46

5364

77103121148161

198224249

276317344

0,110,15

0,220,33

0,450,66

0,81

1,321,80

2,43,34,5

6,6

9,0

10,813,2

18,0

22,227,0

3345546672

90102114

120138150

1,562,1

3,14,5

6,39,1

11,0

17,824,4

324460

87

119

141173

235

288351

426581697852929

116113111463

153817691923

0,410,57

0,821,18

1,31,9

2,4

3,44,4

5,87,8

10,4

14,7

19,7

23,727,9

38

4352

6393

106121146

163184205

226261283

--

--

--

-

--

45,57,5

11

15

1822

30

3745

557590

110120

150170190

200230250

--

--

--

-

--

547399

145

198

235288

392

481585

710968

116114191549

193621852439

256429483204

--

--

--

-

--

9,713,017,3

24,4

33

3846

63

7287

105141166202221

272307342

377435472

--

--

--

-

--

2,43,34,5

6,6

9,0

10,813,2

18,0

22,227

3345546672

90102114

120138150

--

--

--

-

--

5,87,810,4

14,7

19,7

23,727,9

38

4352

6393106121146

163184205

226261283

--

--

--

-

--

324460

87

119

141173

235

288351

426581697852929

116113111463

153817691923

8 poles

1: Not available with EEx de type of protection-: Not available

QUADRATIC TORQUE5 ÷ 50

MOTORTYPE

Pn [kW] Tn [Nm] In [A]

SELF VENTILATED (IC 411)

CONSTANT TORQUE10 ÷ 50

CONSTANT TORQUE10 ÷ 85

Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A] Pn [kW] Tn [Nm] In [A]

FORCE VENTILATED (IC 416)

CONSTANT TORQUE10 ÷ 85

CONSTANT TORQUE10 ÷ 50

In case of operating frequencies out from the ranges shown in the table above, please proceed as follow.

Quadratic torqueIf fmax (maximum supply frequency) is ≤50Hz and the minimum supply frequency fmin is ≥5Hz, the available outputs remain those shown in tables 7 and 8 respectively fortemperature class T3 (or maximum surface temperature T150°C) or T4 (T135°C).

Constant torque1. By applying to the curve 7 or 8 given in the previous page, and depending on the class of temperature or the maximum surface temperature, calculate the Kc value

relate to frequency variation’s limits, and take into consideration the lower only in case of IC411, or that one at the max frequency as for IC416.2. In order to get the Tm value (maximum torque of the motor), multiply the Kc value by the Tn value of the quadratic torque’s column within the class of temperature

and/or max surface temperature (table 7 or table 8).3. The following formulas are to be applied to calculate the nominal power Pn and current In at 400V 50Hz.

Page 36: Motori Per Aree Pericolose

400V 50Hz

343434

PERFORMANCE AT RATED OUTPUT MOMENTOF INERTIA

WEIGHT(IM 1001)

OUTPUT MOTORTYPE

Jkgm2

Approx.kg

kW

SPEED

n

DATA AT RATED VOLTAGE

RATED CURRENT(400 V)

IA p.u.

Ts / Tn

STARTINGTORQUE

p.u.

STARTING CURRENT

Is / Inmin-1

DOUBLE SPEED MOTORSEEx d IIB T3, EEx de IIB T3, IP65

0,310,44

0,620,85

1,181,55

2,053,1

4,4

57

1114

18,52225

30

3745

55

7080

95110130160

71 MA71 MB

80 MA80 MB

90 S90 L

100 LA100 LB

112 M

132 SA132 MA

160 M160 L

180 M180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MC315 MD

0,600,84

1,191,48

2,172,85

3,45,4

7,7

8,311,4

18,523,8

31,435,240,0

49

5667

81

105124

147167190228

3,23,8

3,53,3

3,64,2

4,55,0

6

6,67,3

5,56,0

6,06,56,5

7,0

7,57,5

7,5

7,07,2

7,27,57,57,5

3,03,2

3,43,8

3,94,4

4,64,6

6

6,66,9

5,56,0

6,06,06,0

6,5

6,56,5

6,5

6,36,5

6,56,56,86,8

1,92,4

2,52,6

2,52,9

2,42,5

3,0

2,52,5

1,82,0

2,02,22,2

2,2

2,22,2

2,2

2,02,0

2,02,22,22,2

0,00050,0006

0,00130,0016

0,00330,0040

0,00730,0090

0,0115

0,02380,0300

0,0620,075

0,0900,1100,150

0,190

0,3700,400

0,500

0,9101,050

1,152,102,503,10

16,317,3

21,322,8

27,331,8

4550

60

8090

130145

170190200

215

300320

345

533598

605785860965

2 / 4 poles = 3000 / 1500 min-1 - 50 Hz - single winding YY / ∆ connection0,861,19

1,692,38

2,953,8

4,87,1

9,7

10,515,2

22,827,6

36,142,848,5

58

6882

100

124143

171193223276

0,200,29

0,420,59

0,921,25

1,452,4

3,5

45,6

912

1618,521

26

3137

45

5970

8095

110132

26002640

26002710

27302780

28102850

2985

29102915

28802890

290029202920

2920

29302930

2930

29402940

2940294529452945

2,02,6

2,12,3

2,42,6

2,22,2

3,0

2,32,5

2,02,3

2,32,22,2

2,0

2,22,2

2,2

2,22,2

2,22,42,42,4

13401360

13701380

13801390

14001405

1435

14651475

14501460

146014601465

1465

14651470

1470

14701470

1470147514751475

T1 ÷ T3, T 150°C

0,430,62

0,881,32

1,752,2

2,8

4,05,3

80 MA80 MB

90 S90 L

100 LA100 LB

112 M

132 SA132 MA

920930

930940

940945

945

950960

1,251,52

2,092,90

3,54,7

6,2

8,610,5

3,43,5

3,84,8

4,54,8

5,5

6,77,5

3,13,2

3,34,0

4,13,7

4,3

5,35,5

1,751,8

1,82,0

1,51,7

2,0

2,12,2

2,32,5

2,42,5

2,32,4

2,7

2,42,6

0,00240,0027

0,00370,0050

0,00730,0090

0,0115

0,02380,0300

21,323,3

27,834,3

4550

60

8090

4 / 6 poles = 1500 / 1000 min-1 - 50 Hz - single winding YY / ∆ connection1,621,90

2,663,90

4,55,3

6,5

9,111,8

0,310,45

0,660,95

1,01,4

1,85

2,93,7

14001410

14151420

14201420

1430

14401445

T1 ÷ T3, T 150°C

Is = Starting current; Ts = Starting torque.The motors shown on this page are not multivoltage.

6,68,8

111315

18,5

2530

40

5163

7085

103118140

160 M160 L

180 M180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

965970

970970970

970

970970

975

980980

980980980980980

9,012,4

15,218,120,0

25

2836

50

6276

86100124143162

6,06,5

6,87,07,0

7,0

6,57,0

7,0

6,56,5

6,56,56,56,56,5

5,05,5

5,86,56,5

6,5

6,57,0

7,0

6,06,0

6,26,06,06,06,0

1,92,2

2,22,22,0

2,0

2,02,0

2,0

2,02,0

2,01,61,81,81,8

2,02,2

2,22,22,2

2,2

2,22,2

2,2

2,22,2

2,22,02,02,02,0

0,0630,075

0,0900,1600,220

0,270

0,4200,520

0,670

1,0501,250

1,432,603,003,604,45

135145

165190195

215

390315

360

483523

5757558059001000

4 / 6 poles = 1500 / 1000 min-1 - 50 Hz - two separate windings12,817,1

20,924,728,5

35

4352

73

93114

124147181209247

4,46

7,59

10

12,5

1620

27

3442

4755708090

14701475

147514751475

1475

14751475

1480

14801480

14801480148014801480

T1 ÷ T3, T 150°C

Page 37: Motori Per Aree Pericolose

400V 50Hz

35

Is = Starting current; Ts = Starting torque.The motors shown on this page are not multivoltage.

DOUBLE SPEED MOTORSEEx d IIB T3, EEx de IIB T3, IP65

3,74,46

7,59

10,5

1519

25

3543

48607077

100

160 MA160 MB160 L

180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

710715725

730730

735

735735

735

740740

740740740740740

5,77,39,5

11,913,8

17

2320

41

5162

7187

100114143

5,56,06,0

6,06,0

6,0

6,06,0

6,0

6,06,0

6,06,06,06,06,0

4,54,85,0

5,05,0

5,8

6,06,0

6,0

5,55,5

5,55,55,55,55,5

1,71,81,8

1,81,8

1,8

1,81,8

1,8

1,81,8

1,81,81,81,81,8

1,71,71,8

1,81,8

1,8

1,81,8

1,8

1,81,8

1,81,81,81,81,8

0,0870,0920,110

0,1600,220

0,270

0,4200,520

0,670

1,0501,250

2,812,623,003,604,40

130135145

190195

215

290315

360

523553

6057558059001000

6 / 8 poles = 1000 / 750 min-1 - 50 Hz - two separate windings7,69,0

11,9

14,317,1

20

2835

51

6578

87109128141181

2,63,34,4

5,56,5

8

1115

18,5

2632

3745526075

965965970

970970

970

975975

975

975975

980980980980980

T1 ÷ T3, T 150°C

0,350,62

0,92

1,221,9

2,4

3,74,6

78

11

1518,5

21

2332

40

5163

668095110132

80 MA80 MB

90 L

100 LA100 LB

112 M

123 SA132 MA

160 MA160 MB160 L

180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

710690

665

705705

700

705705

710715725

730730

735

735735

735

740740

735740740740740

0,831,45

1,71

2,093,3

4,2

6,58,1

10,012,416,2

2125

29

3349

57

6778

95105125147171

2,83,5

3,5

4,44,8

5,5

6,06,0

6,06,06,0

6,06,0

6,5

7,07,0

7,0

6,56,5

6,86,56,56,56,5

2,32,7

2,3

3,73,8

4,1

4,14,2

4,54,54,5

5,05,0

6,0

6,06,0

6,0

5,55,5

5,75,55,55,55,5

1,31,7

1,9

1,92,0

2,0

2,82,5

1,81,81,8

2,02,0

2,0

2,22,2

2,2

2,02,0

2,02,02,02,02,0

1,62,1

2,4

2,22,4

2,5

2,22,2

1,81,81,8

2,02,0

2,2

2,22,2

2,2

2,02,0

2,22,02,02,02,0

0,00240,0027

0,0040

0,00930,012

0,017

0,0380,046

0,0870,0930,110

0,1600,220

0,270

0,4200,570

0,620

1,051,25

1,372,623,003,604,40

2123

32

4750

60

8095

130135145

190195

215

390315

360

523553

6057558058951000

4 / 8 poles = 1500 / 750 min-1 - 50 Hz - single winding YY / ∆ connection1,191,66

2,04

2,854,6

5,5

8,610,1

13,315,221

2936

41

4457

71

90107

114140163185223

0,180,31

0,42

0,600,95

1,2

2,12,6

45

6,5

911

13

1522

26

3137

4552637588

12701300

1300

13801410

1420

14201430

146014601460

14651465

1465

14701470

1470

14751475

14801480148014801480

T1 ÷ T3, T 150°C

PERFORMANCE AT RATED OUTPUT MOMENTOF INERTIA

WEIGHT(IM 1001)

OUTPUT MOTORTYPE

Jkgm2

Approx.kg

kW

SPEED

n

DATA AT RATED VOLTAGE

RATED CURRENT(400 V)

IA p.u.

Ts / Tn

STARTINGTORQUE

p.u.

STARTING CURRENT

Is / Inmin-1

Page 38: Motori Per Aree Pericolose

6,37,510

1517,5

20

2332

38

4863

667690

105118

160 MA160 MB160 L

180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

710710725

730730

735

735735

735

740740

735740740740740

9,010,914,7

2123

25

3349

57

6278

95100119139154

6,76,46,6

6,06,3

6,8

7,07,0

7,4

6,96,5

6,86,86,96,87,3

4,54,54,5

5,05,0

6,0

6,06,0

6,0

5,55,5

5,75,55,55,55,5

2,01,92,0

2,02,1

2,1

2,22,2

2,3

2,12,0

2,02,12,12,12,2

2,02,02,0

2,02,1

2,6

2,22,2

2,2

2,12,0

2,22,12,12,12,2

0,0870,0930,110

0,1600,220

0,270

0,4200,570

0,620

1,051,25

1,372,623,003,604,40

130135145

190195

215

275300

345

510540

6057558058951000

4 / 8 poles = 1500 / 750 min-1 - 50 Hz - single winding YY / ∆ connection12,014,319,0

2934

39

4457

68

85107

114133155177200

3,64,45,9

910,3

11

1522

26

2937

4550607179

146014601460

14651465

1465

14701470

1470

14751475

14801480148014801480

T4, T 135°C

400V 50Hz

36

DOUBLE SPEED MOTORSEEx d IIB T4, EEx de IIB T4, IP65

1113

172224

27

3443

50

6572

8593

110132

160 M160 L

180 M180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MC315 MD

18,524

303740

47

5367

77

104117

139150170200

5,56,5

6,56,56,8

7,8

8,27,8

8,3

7,58,0

8,08,98,99,1

5,56,3

6,66,06,3

7,2

7 26,9

7,1

6,67,2

7,27,68,08,2

1,82,2

2,22,22,3

2,4

2,42,3

2,4

2,22,2

2,22,62,62,7

0,0620,075

0,0900,1100,150

0,190

0,3700,400

0,500

0,9101,05

1,152,102,503,10

135145

170190200

215

285305

330

520585

605785860965

2 / 4 poles = 3000 / 1500 min-1 - 50 Hz - single winding YY / ∆ connection2327

354549

55

6682

95

120135

161171198239

911,5

14,518,520

23,5

2835

41

5663

728194

110

28802890

290029202920

2920

29302930

2930

29402940

2940294529452945

2,02,4

2,52,22,3

2,2

2,42,3

2,4

2,32,4

2,42,82,82,9

14501460

146014601465

1465

14651470

1470

14701470

1470147514751475

T4, T 135°C

6,37,9

9,912,314,2

17,5

2528,5

36

4454

637085

103112

160 M160 L

180 M180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

970975

975975975

970

970970

980

980980

980985980980985

11,013,0

16,318,320

24

3437

53

6372

918698

126138

6,37,6

7,87,47,4

7,4

7,07,4

7,8

7,57,6

6,57,97,97,48,1

5,26,1

6,56,86,8

6,8

6,57,4

7,9

6,26,8

6,27,07,66,97,1

2,02,5

2,42,32,1

2,1

2,02,1

2,2

2,32,3

2,01,92,22,12,3

2,12,4

2,52,32,3

2,3

2,22,3

2,5

2,32,5

2,22,32,52,32,4

0,0630,075

0,0900,1600,220

0,270

0,4200,520

0,670

1,051,25

1,432,603,003,604,45

135145

165190195

215

275300

345

470510

575755805895

1000

4 / 6 poles = 1500 / 1000 min-1 - 50 Hz - two separate windings13,717,2

212427

34

4655

67

8199

125123151184200

4,25,4

6,78,69,5

11,9

1619

24

3037

4247557076

14751480

148014801480

1480

14751475

1480

14801480

14851485148514851485

T4, T 135°C

3,74,46

6,79

10

1417

23

3543

4860667188

160 MA160 MB160 L

180 LA180 LB

200 L

225 S225 M

250 M

280 S280 M

315 SM315 MA315 MB315 MC315 MD

710715725

730730

735

735735

735

740740

740740740740740

5,77,39,5

10,813,8

17,1

2227

35

5162

7187

100114143

5,56,06,0

6,76,0

6,3

6,47,4

6,5

6,06,0

6,06,06,46,56,8

4,54,85,0

5,55,0

6,2

6,36,7

6,9

5,55,5

5,55,55,85,86,3

1,71,81,8

2,01,8

1,9

1,92,0

2,0

1,81,8

1,81,81,92,02,0

1,71,71,8

2,01,8

1,9

1,92,0

2,1

1,81,8

1,81,81,91,92,0

0,0870,0920,110

0,1600,220

0,270

0,4200,520

0,670

1,051,25

2,812,623,003,604,40

130135145

190195

215

275300

345

510540

6057558058951000

6 / 8 poles = 1000 / 750 min-1 - 50 Hz - two separate windings7,69,011,9

12,717,1

19,0

2731

47

6578

87109128141181

2,63,34,4

56,5

7,5

10,513,5

16

2632

3745495766

965965970

970970

970

975975

975

975975

980980980980980

T4, T 135°C

PERFORMANCE AT RATED OUTPUT MOMENTOF INERTIA

WEIGHT(IM 1001)

OUTPUT MOTORTYPE

Jkgm2

Approx.kg

kW

SPEED

n

DATA AT RATED VOLTAGE

RATED CURRENT(400 V)

IA p.u.

Ts / Tn

STARTINGTORQUE

p.u.

STARTING CURRENT

Is / Inmin-1

Is = Starting current; Ts = Starting torque.The motors shown on this page are not multivoltage.

Page 39: Motori Per Aree Pericolose

PERFORMANCE AT RATED OUTPUT

MOMENTOF INERTIA

WEIGHTIM 1001

RATEDOUTPUT

MOTORTYPE

J

kgm2

Approx.

kg

kW

BREAKDOWNTORQUE

TMAX / Tn

p.u.p.u. p.u.

Ts / Tn

SPEED

1/min

n

EFFICIENCY

ηη

%

RATEDCURRENT

(400V)

I

A

RATEDTORQUE

Tn

Nm

POWERFACTOR

COS COS ϕϕ

DATA AT RATED VOLTAGE

STARTINGCURRENT

STARTINGTORQUE

Is / In

400V 50HzEEx d IIC, EEx de IIC, IP65

37

7590

280 S2280 M2

29602960

93,694,2

133157

242290

6,87,2

2,32,3

2,72,7

0,3500,416

575630

0,870,88

225 M245 2960 92,5 80 145 6,6 2,4 3,0 0,225 3200,88

250 M255 2960 93,0 98 177 6,7 2,4 3,0 0,250 3600,87

110132160200

3037

160 MA2160 MB2160 L2

292029252925

88,489,890,0

21,929,036,7

180 M2

364960

6,26,46,8

2,22,22,3

2,83,03,0

0,0300,0350,040

155160165

1115

18,5

22

3000 min-1 = 2 poles - 50 Hz0,820,830,81

2930 90,5 41,8 72 6,8 2,4 3,0 0,048 1880,84

200 LA2200 LB2

29452945

92,092,2

5467

97120

6,76,9

2,32,4

2,93,0

0,1650,180

250260

0,870,87

315 SM2315 MA2315 MC2315 MD2

2975297029752980

94,394,394,494,7

194235281351

353424513640

6,46,56,56,5

2,42,52,52,5

2,42,52,52,5

0,950,951,121,30

1050105011151195

0,870,860,870,87

T1 ÷ T4, T 135°C

18,522

180 M4180 L4

14601465

90,090,5

36,241,8

121143

6,26,3

2,32,4

2,52,5

0,0900,110

190240

0,820,84

1115

160 M4160 L4

14551460

88,689,4

22,129,9

7298

5,25,8

2,02,2

2,12,4

0,0340,075

165182

0,810,81

200 L430 1470 91,6 56 195 6,4 2,4 2,8 0,180 2700,84

3745

225 S4225 M4

14751475

92,592,5

6782

239291

6,56,5

2,32,4

2,82,8

0,3200,410

325342

0,860,86

7590

280 S4280 M4

14801480

93,793,9

134157

483580

7,07,1

2,52,7

2,32,4

0,8851,060

608665

0,860,88

250 M455 1475 93,0 98 356 6,4 2,3 2,6 0,520 4100,87

110132160200

1500 min-1 = 4 poles - 50 Hz

315 SM4315 MA4315 MC4315 MD4

1488148514851485

93,694,594,895,3

200237287353

70584810281285

6,56,26,26,5

2,62,52,52,5

2,62,52,52,6

2,102,102,503,10

1080108012101370

0,850,850,850,86

T1 ÷ T4, T 135°C

7590110132143

315 SM6315 MA6315 MB6315 MC6315 MD6

985985985985985

94,094,094,093,394,8

136163199238253

730872106512781385

6,36,06,06,36,3

2,62,52,52,52,5

2,62,52,52,52,5

2,602,603,003,604,40

10001000107011801310

0,830,850,840,850,86

180 L615 970 88,2 30,0 147 5,2 2,3 2,2 0,130 2310,82

18,522

200 LA6200 LB6

970972

88,289,0

36,543

182216

5,25,5

2,12,4

2,32,4

0,1700,220

250270

0,830,83

7,511

160 M6160 L6

965967

86,088,0

15,422,0

74108

5,05,5

2,22,3

2,32,5

0,0870,110

175182

0,820,82

225 M630 975 90,5 58 294 6,2 2,4 2,4 0,470 3300,84

4555

280 S6280 M6

980980

92,593,0

84103

440535

6,06,0

2,52,5

2,52,5

0,8501,075

560665

0,840,83

250 M637 975 91,0 70 362 6,5 2,6 2,6 0,570 4000,84

1000 min-1 = 6 poles - 50 Hz T1 ÷ T4, T 135°C

750 min-1 = 8 poles - 50 Hz T1 ÷ T4, T 135°C

18,522

3745

30

557590110132

15

45,57,5

11

225 S8225 M8

280 S8280 M8

250 M8

160 MA8160 MB8160 L8

180 L8

200 L8

315 SM8315 MA8315 MC8315 MD8315 ME8

735735

730730

730

710720720

725

725

740740740740740

92,593,0

89,090,0

91,0

81,082,484,7

86,7

88,0

93,593,894,494,594,6

0,800,80

0,760,76

0,76

0,730,740,74

0,75

0,75

0,820,820,830,830,83

7287

39,546,4

63

9,813,017,3

24,4

32,8

104139166202243

480569

242288

392

547399

145

197

709967116014181702

6,06,0

5,25,3

5,5

4,24,24,2

4,5

5,0

6,56,06,26,26,2

2,52,5

2,22,2

2,3

1,91,92,0

2,0

2,1

2,32,12,22,22,2

2,52,5

2,42,4

2,5

2,12,12,1

2,2

2,3

2,42,22,32,32,3

1,051,25

0,4200,520

0,620

0,0800,0920,110

0,160

0,220

2,82,83,54,04,3

505640

324340

405

140151184

255

280

10501050128013701440

Is = Starting current, Ts = Starting torque, Tmax = Breakdown torque.

The motors shown on this page are not multivoltage.

Page 40: Motori Per Aree Pericolose

38

400V 50Hz

PERFORMANCE AT RATED OUTPUT

RATEDOUTPUT

MOTORTYPE

kW

SPEED

min-1

n

DATA AT RATED VOLTAGE

RATEDCURRENT

(400V)

A

STARTINGCURRENT

Is / In

p.u. p.u.

Ts / Tn

STARTINGTORQUE

WEIGHTIM 1001

Approx.

kg

MOMENTOF INERTIA

J

kgm2

I

2 / 4 poles = 3000 / 1500 min-1 - 50 Hz - single winding YY / ∆ connection

3745

55

7080

30

18,52225

1114

95110130160

3137

45

5970

26

1618,521

912

8095110132

29302930

2930

29402940

2920

290029202920

28802890

2940294529452945

14651470

1470

14701470

1465

146014601465

14501460

1470147514751475

6882

100

124143

58

36,142,848,5

22,827,6

171193223276

5667

81

105124

49

31,435,240,0

18,523,8

147167190228

7,57,5

7,5

7,07,2

7,0

6,06,56,5

5,56,0

7,27,57,57,5

6,56,5

6,5

6,36,5

6,5

6,06,06,0

5,56,0

6,56,56,86,8

2,22,2

2,2

2,02,0

2,2

2,02,22,2

1,82,0

2,02,22,22,2

2,22,2

2,2

2,22,2

2,0

2,32,22,2

2,02,3

2,22,42,42,4

0,3700,400

0,500

0,9101,050

0,190

0,0900,1100,150

0,0620,075

1,152,102,503,10

325340

360

615675

270

190240250

165180

1080108512101375

225 S225 M

250 M

280 S280 M

200 L

180 M180 LA180 LB

160 M160 L

315 SM315 MA315 MC315 MD

T1 ÷ T3, T 150°C

4 / 6 poles = 1500 / 1000 min-1 - 50 Hz - two separate windings

2530

40

5163

18,5

111315

6,68,8

7085

103118140

1620

27

3442

12,5

7,59

10

4,46

4755708090

14751475

1480

14801480

1475

147514751475

14701475

14801480148014801480

970970

975

980980

970

970970970

965970

980980980980980

4352

73

93114

35

20,924,728,5

12,817,1

124147181209247

2836

50

6276

25

15,218,120,0

9,012,4

86100124143162

6,57,0

7,0

6,56,5

7,0

6,87,07,0

6,06,5

6,56,56,56,56,5

6,57,0

7,0

6,06,0

6,5

5,86,56,5

5,05,5

6,26,06,06,06,0

2,02,0

2,0

2,02,0

2,0

2,22,22,0

1,92,2

2,01,61,81,81,8

2,22,2

2,2

2,22,2

2,2

2,22,22,2

2,02,2

2,22,02,02,02,0

0,4200,520

0,670

1,0501,250

0,270

0,0900,1600,220

0,0630,075

1,432,603,003,604,45

310335

410

565600

245

190215225

165180

10001005107011801310

225 S225 M

250 M

280 S280 M

200 L

180 M180 LA180 LB

160 M160 L

315 SM315 MA315 MB315 MC315 MD

T1 ÷ T3, T 150°C

1518,5

911

14651465

730730

28,536,1

20,924,7

6,06,0

5,05,0

2,02,0

2,02,0

0,1600,220

255260

180 LA180 LB

21

2332

13

1522

1465

14701470

735

735735

41

4457

29

3349

6,5

7,07,0

6,0

6,06,0

2,0

2,22,2

2,2

2,22,2

0,270

0,4200,570

285

325340

200 L

225 S225 M

40

5163

26

3137

1470

14751475

735

740740

71

90107

57

6778

7,0

6,56,5

6,0

5,55,5

2,2

2,02,0

2,2

2,02,0

0,620

1,0501,250

405

610645

250 M

280 S280 M

78

11

45

6,5

146014601460

710715725

13,315,220,9

10,012,416,2

6,06,06,0

4,54,54,5

1,81,81,8

1,81,81,8

0,0870,0930,110

175175195

160 MA160 MB160 L

4 / 8 poles = 1500 / 750 min-1 - 50 Hz - single winding YY / ∆ connection

668095

110132

4552637588

14801480148014801480

735740740740740

114140163185223

95105125147171

6,86,56,56,56,5

5,75,55,55,55,5

2,02,02,02,02,0

2,22,02,02,02,0

1,372,623,003,604,40

10401040107011851315

315 SM315 MA315 MB315 MC315 MD

T1 ÷ T3, T 150°C

7,59

5,56,5

970970

730730

14,317,1

11,913,8

6,06,0

5,05,0

1,81,8

1,81,8

0,1600,220

255260

180 LA180 LB

10,5

1519

8

1115

970

975975

735

735735

20

2835

17

2320

6,0

6,06,0

5,8

6,06,0

1,8

1,81,8

1,8

1,81,8

0,270

0,4200,520

285

325340

200 L

225 S225 M

25

3543

18,5

2632

975

975975

735

740740

51

6578

41

5162

6,0

6,06,0

6,0

5,55,5

1,8

1,81,8

1,8

1,81,8

0,670

1,0501,250

405

610645

250 M

280 S280 M

3,74,46

2,63,34,4

965965970

710715725

7,69,0

11,9

5,77,39,5

5,56,06,0

4,54,85,0

1,71,81,8

1,71,71,8

0,0870,0920,110

175180195

160 MA160 MB160 L

6 / 8 poles = 1000 / 750 min-1 - 50 Hz - two separate windings T1 ÷ T3, T 150°C

48607077

100

3745526075

980980980980980

740740740740740

87109128141181

7187

100114143

6,06,06,06,06,0

5,55,55,55,55,5

1,81,81,81,81,8

1,81,81,81,81,8

2,812,623,003,604,40

10401040107011851315

315 SM315 MA315 MB315 MC315 MD

Is = Starting current; Ts = Starting torque.The motors shown o this page are not multivoltage.

DOUBLE SPEED MOTORSEEx d IIC, EEx de IIC, IP65

Page 41: Motori Per Aree Pericolose

39

DIMENSIONS D5 71-132 IM B3

AA

112

125

140

140

160

190

216

216

AB AC B BB BC CAD CA H KFRAME SIZE

SLLMSM

71

80

90

132

A

7

9

9

9

12

12

12

12

71

80

90

90

100

112

132

132

104

112

111

126

138

171

168

168

45

50

56

56

63

70

89

89

10

12,5

12,5

12,5

15

15

22,5

22,5

110

125

125

150

170

170

185

223

90

100

100

125

140

140

140

178

175

185

192

192

214

214

236

236

255

275

312

302

336

336

386

386

135

150

175

175

195

225

255

255

26

25

30

30

31

39

41

41

HD

161

180

206

206

240

252

273

273

100112

HA

8

8

10

10

12

12

15

15

LD

266

299

314

354

397

437

473

511

LC WD E F GA DA EA FA GC

FRAME SIZE

SLLMSM

71

80

90

132

L

16

21,5

27

27

31

31

41

41

5

6

8

8

8

8

10

10

30

40

50

50

60

60

80

80

14

19

24

24

28

28

38

38

16

21,5

27

27

31

31

41

41

5

6

8

8

8

8

10

10

30

40

50

50

60

60

80

80

14

19

24

24

28

28

38

38

120

130

142

142

162

172

202

202

299

342

367

407

461

501

557

595

297

330

345

385

425

468

504

542

100112

SHAFT EXTENSION

Page 42: Motori Per Aree Pericolose

40

DIMENSIONS D5 71-132 IM B5 AND IM V1

N130

165

165

165

215

215

265

265

P LA TKFFRAME SIZE

SLLMSM

71

80

90

132

M3,5

3,5

3,5

3,5

4

4

4

4

9,5

11,5

11,5

11,5

14,0

14,0

14,0

14,0

6

9

9

9

14

14

14

14

160

200

200

200

250

250

300

300

110

130

130

130

180

180

230

230

100112

FLANGE B5

AD

255

275

304

304

336

336

386

386

AE L LC LD W LED

LBE F GA GC

FRAME SIZE

SLLMSM

71

80

90

132

AC

16

21,5

27

27

31

31

41

41

16

21,5

27

27

31

31

41

41

5

6

8

8

8

8

10

10

30

40

50

50

60

60

80

80

14

19

24

24

28

28

38

38

267

290

295

335

368

408

424

462

120

130

142

142

172

172

202

202

297

330

345

328

428

468

504

542

299

342

367

407

461

501

557

595

239

262

267

307

341

381

397

435

266

299

314

354

397

437

473

511

125

182

182

182

212

212

264

264

175

185

192

192

214

214

236

236

EA30

40

50

50

60

60

80

80

100112

DA14

19

24

24

28

28

38

38

FA5

6

8

8

8

8

10

10

SHAFT EXTENSION

Page 43: Motori Per Aree Pericolose

41

DIMENSIONS D5 71-132 IM B35

LD

266

299

314

354

397

437

473

511

LC WM

FRAME SIZE

SLLMSM

71

80

90

132

L

130

165

165

165

215

215

265

265

120

130

142

142

162

172

202

202

299

342

367

407

461

501

557

595

297

330

345

385

425

468

504

542

100112

FLANGE B5 SHAFT EXTENSIONN

110

130

130

130

180

180

230

230

P160

200

200

200

250

250

300

300

LA6

9

9

9

14

14

14

14

KF9,5

11,5

11,5

11,5

14,0

14,0

14,0

14,0

T3,5

3,5

3,5

3,5

4

4

4

4

D14

19

24

24

28

28

38

38

E30

40

50

50

60

60

80

80

F5

6

8

8

8

8

10

10

GA16

21,5

27

27

31

31

41

41

DA14

19

24

24

28

28

38

38

EA30

40

50

50

60

60

80

80

FA5

6

8

8

8

8

10

10

GC16

21,5

27

27

31

31

41

41

AA

112

125

140

140

160

190

216

216

AB AC B BB BC CAD CA HFRAME SIZE

SLLMSM

71

80

90

132

A

71

80

90

90

100

112

132

132

104

112

111

126

138

171

168

168

45

50

56

56

63

70

89

89

10

12,5

12,5

12,5

15

15

22,5

22,5

110

125

125

150

170

170

185

223

90

100

100

125

140

140

140

178

175

185

192

192

214

214

236

236

255

275

312

302

336

336

386

386

135

150

175

175

195

225

255

255

26

25

30

30

31

39

41

41

HD

161

180

206

206

240

252

273

273

100112

HA

8

8

10

10

12

12

15

15

K

7

9

9

9

12

12

12

12

Page 44: Motori Per Aree Pericolose

DIMENSIONS D5 71-112 IM B14 AND IM V18

42

SHAFT EXTENSIONE

14

19

24

24

28

28

F GA GADAFRAME SIZE

SLLM

71

80

90

D16

21,5

27

27

31

31

14

19

24

24

28

28

16

21,5

27

27

31

31

5

6

8

8

8

8

30

40

50

50

60

60100112

DA14

19

24

24

28

28

EA30

40

50

50

60

60

FA5

6

8

8

8

8

GC16

21,5

27

27

31

31

AD

255

275

304

304

336

336

AE L LC LD WM

LBN P KF

FRAME SIZE

SLLM

71

80

90

AC

M6

M6

M8

M8

M8

M8

105

120

140

140

160

160

70

80

95

95

110

110

85

100

115

115

130

130

120

130

142

142

172

172

297

330

345

328

428

468

299

342

367

407

461

501

239

262

267

307

341

381

266

299

314

354

397

437

125

182

182

182

212

212

175

185

192

192

214

214100112

T2,5

3,0

3,0

3,0

3,5

3,5

FLANGE B14

Page 45: Motori Per Aree Pericolose

DIMENSIONS D5 160-315 IM B3

43

AA

254

254

279

279

318

356

356

356

406

406

457

457

457

457

508

508

508

508

508

508

AB AC BA BB BC C CAB H HA HD LFRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

A

648

648

648

723

723

830

800

830

830

830

960

960

960

960

1102

1132

1102

1132

1102

1132

446

446

466

488

508

593

593

593

618

618

710

710

710

710

820

820

820

820

820

820

22

22

24

24

24

28

28

28

28

28

40

40

40

40

45

45

45

45

45

45

160

160

180

180

200

225

225

225

250

250

280

280

280

280

315

315

315

315

315

315

223

179

179

216

178

260

235

235

178

178

272

272

221

221

299

299

299

299

299

299

108

108

121

121

133

149

149

149

168

168

190

190

190

190

216

216

216

216

216

216

21

21

21

21

22,5

24,5

24,5

24,5

28,5

28,5

30,5

30,5

30,5

30,5

32

32

32

32

32

32

296

296

283

321

350

360

360

360

406

406

480

480

480

480

520

520

520

520

520

520

95

95

65

90

75

100

100

100

95

95

110

110

110

110

165

165

165

165

165

165

210

254

241

279

305

286

311

311

349

349

368

368

419

419

457

457

457

457

457

457

314

314

314

354

354

411

411

411

411

411

490

490

490

490

604

604

604

604

604

604

300

300

324

324

368

406

406

406

465

465

540

540

540

540

590

590

590

590

590

590

55

55

58

58

63

76

76

76

90

90

90

90

90

90

110

110

110

110

110

110

K

14

14

14

14

18

18

18

18

22

22

22

22

22

22

27

27

27

27

27

27

W

761

761

761

836

836

945

915

945

945

945

1110

1110

1110

1110

1252

1282

1252

1282

1252

1282

D E GA DA EA FA GCFFRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

LC

45

45

45

45

45

59

59

59

59

59

64

64

64

64

64

69

64

69

64

69

12

12

12

12

12

16

16

16

16

16

18

18

18

18

18

18

18

18

18

18

110

110

110

110

110

110

110

110

110

110

140

140

140

140

140

140

140

140

140

140

42

42

42

42

42

55

55

55

55

55

60

60

60

60

60

65

60

65

60

65

45

45

51,5

51,5

59

64

59

64

64

69

69

79,5

69

79,5

69

85

69

85

74,5

95

12

12

14

14

16

18

16

18

18

18

18

20

18

20

18

22

18

22

20

25

110

110

110

110

110

140

110

140

140

140

140

140

140

140

140

170

140

170

140

170

42

42

48

48

55

60

55

60

60

65

65

75

65

75

65

80

65

80

70

90

279

279

279

296

296

318

288

318

318

318

350

350

350

350

387

417

387

417

387

417

SHAFT EXTENSION

Dimensions not valid for IIC motors.

Page 46: Motori Per Aree Pericolose

Z = n u m b e r o f h o l e s

DIMENSIONS D5 160-315 IM B5 AND IM V1

44

AD

314

314

314

354

354

411

411

411

411

411

490

490

490

490

604

604

604

604

604

604

L LC WD E F GA

LDDA EA FA GC

FRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

AC

45

45

45

45

45

59

59

59

59

59

64

64

64

64

64

69

64

69

64

69

12

12

12

12

12

16

16

16

16

16

18

18

18

18

18

18

18

18

18

18

110

110

110

110

110

110

110

110

110

110

140

140

140

140

140

140

140

140

140

140

42

42

42

42

42

55

55

55

55

55

60

60

60

60

60

65

60

65

60

65

45

45

51,5

51,5

59

64

59

64

64

69

69

79,5

69

79,5

69

85

69

85

74,5

95

12

12

14

14

16

18

16

18

18

18

18

20

18

20

18

22

18

22

20

25

110

110

110

110

110

140

110

140

140

140

140

140

140

140

140

170

140

170

140

170

42

42

48

48

55

60

55

60

60

65

65

75

65

75

65

80

65

80

70

90

279

279

279

296

296

318

288

318

318

318

350

350

350

350

387

417

387

417

387

417

710

710

710

790

790

895

865

895

895

895

1045

1045

1045

1045

1177

1207

1177

1207

1177

1207

761

761

761

836

836

945

915

945

945

945

1110

1110

1110

1110

1252

1282

1252

1282

1252

1282

648

648

648

723

723

830

800

830

830

830

960

960

960

960

1102

1132

1102

1132

1102

1132

286

286

286

308

308

368

368

368

368

368

430

430

430

430

505

505

505

505

505

505

SHAFT EXTENSION

Dimensions not valid for IIC motors.

M15

15

15

15

18

16

16

16

18

18

18

18

18

18

22

22

22

22

22

22

N P T ZSFRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

LA4

4

4

4

4

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

5

5

5

5

5

5

5

5

5

5

5

5

5

5

6

6

6

6

6

6

18

18

18

18

18

18

18

18

18

18

18

18

18

18

22

22

22

22

22

22

350

350

350

350

400

450

450

450

550

550

550

550

550

550

660

660

660

660

660

660

250

250

250

250

300

350

350

350

450

450

450

450

450

450

550

550

550

550

550

550

300

300

300

300

350

400

400

400

500

500

500

500

500

500

600

600

600

600

600

600

FLANGE

Page 47: Motori Per Aree Pericolose

Z = n u m b e r o f h o l e s

DIMENSIONS D5 160-315 IM B35

45

Dimensions not valid for IIC motors.

D279

279

279

296

296

318

288

318

318

318

350

350

350

350

387

417

387

417

387

417

E F DA EA FA GC LAGA M N P ZFRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

W

4

4

4

4

4

8

8

8

8

8

8

8

8

8

8

8

8

8

8

8

350

350

350

350

400

450

450

450

550

550

550

550

550

550

660

660

660

660

660

660

250

250

250

250

300

350

350

350

450

450

450

450

450

450

550

550

550

550

550

550

300

300

300

300

350

400

400

400

500

500

500

500

500

500

600

600

600

600

600

600

15

15

15

15

18

16

16

16

18

18

18

18

18

18

22

22

22

22

22

22

45

45

45

45

45

59

59

59

59

59

64

64

64

64

64

69

64

69

64

69

12

12

12

12

12

16

16

16

16

16

18

18

18

18

18

18

18

18

18

18

110

110

110

110

110

110

110

110

110

110

140

140

140

140

140

140

140

140

140

140

42

42

42

42

42

55

55

55

55

55

60

60

60

60

60

65

60

65

60

65

45

45

51,5

51,5

59

64

59

64

64

69

69

79,5

69

79,5

69

85

69

85

74,5

95

12

12

14

14

16

18

16

18

18

18

18

20

18

20

18

22

18

22

20

25

110

110

110

110

110

140

110

140

140

140

140

140

140

140

140

170

140

170

140

170

42

42

48

48

55

60

55

60

60

65

65

75

65

75

65

80

65

80

70

90

S18

18

18

18

18

18

18

18

18

18

18

18

18

18

22

22

22

22

22

22

T5

5

5

5

5

5

5

5

5

5

5

5

5

5

6

6

6

6

6

6

SHAFT EXTENSION FLANGE

AA

254

254

279

279

318

356

356

356

406

406

457

457

457

457

508

508

508

508

508

508

AB AC BA BB BC C CAB H HA HD LCFRAME SIZE

2-8

POLES

MLMLLS

SMSMMA

MA-MCMD

MD-ME

M

D5_160

D5_180

D5_200

D5_225

D5_250

2-4

4-8

2-8

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

2

4-8

D5_315

S

M

D5_280M

A

761

761

761

836

836

945

915

945

945

945

1110

1110

1110

1110

1252

1282

1252

1282

1252

1282

446

446

466

488

508

593

593

593

618

618

710

710

710

710

820

820

820

820

820

820

22

22

24

24

24

28

28

28

28

28

40

40

40

40

45

45

45

45

45

45

160

160

180

180

200

225

225

225

250

250

280

280

280

280

315

315

315

315

315

315

223

179

179

216

178

260

235

235

178

178

272

272

221

221

299

299

299

299

299

299

108

108

121

121

133

149

149

149

168

168

190

190

190

190

216

216

216

216

216

216

21

21

21

21

22,5

24,5

24,5

24,5

28,5

28,5

30,5

30,5

30,5

30,5

32

32

32

32

32

32

296

296

283

321

350

360

360

360

406

406

480

480

480

480

520

520

520

520

520

520

95

95

65

90

75

100

100

100

95

95

110

110

110

110

165

165

165

165

165

165

210

254

241

279

305

286

311

311

349

349

368

368

419

419

457

457

457

457

457

457

314

314

314

354

354

411

411

411

411

411

490

490

490

490

604

604

604

604

604

604

300

300

324

324

368

406

406

406

465

465

540

540

540

540

590

590

590

590

590

590

55

55

58

58

63

76

76

76

90

90

90

90

90

90

110

110

110

110

110

110

K

14

14

14

14

18

18

18

18

22

22

22

22

22

22

27

27

27

27

27

27

L

648

648

648

723

723

830

800

830

830

830

960

960

960

960

1102

1132

1102

1132

1102

1132

Page 48: Motori Per Aree Pericolose

46

DIMENSIONS D5 355-400 IM B3

2

4-8

FRAME SIZE

D5_355

D5_400

L75

100

75

100

D140

210

140

210

E20

29

20

28

F79,5

106

79,5

106

GA75

75

75

75

DA140

140

140

140

EA20

20

20

20

FA79,5

79,5

79,5

79,5

GCPOLES

SHAFT EXTENSION

L 2

4-8

2

4-8

FRAME SIZE

LX - LW - LY

D5_355

D5_400

L

LZLX - LW - LY

LZ

610

610

686

686

686

686

A

130

130

150

150

150

150

AA

740

740

836

836

836

836

AB

750

750

805

805

805

805

AC

695

695

730

730

730

730

AD

755

755

820

820

820

820

AE

630

630

710

710

710

710

B

706

706

880

1025

880

1025

BB

38

38

85

85

85

85

BC

254

254

280

280

280

280

C

526

596

655

755

655

755

CA

355

355

400

400

400

400

H

26

26

35

35

35

35

HA

1050

1050

1130

1130

1130

1130

HD

27

27

33

33

33

33

K

1550

1620

1780

1880

1850

1950

L

1695

1765

1925

2025

1995

2095

LC

550

620

580

580

650

650

WPOLES

2

4-8

Page 49: Motori Per Aree Pericolose

47

DIMENSIONS D5 355-400 IM V1

2

4-8

FRAME SIZE

D5_355

D5_400

L740

740

940

940

M680

680

880

880

N800

800

1000

1000

P25

25

26

26

LAn°8x24

n°8x24

n°8x28

n°8x28

KF6

6

6

6

TPOLES

FLANGE

L 2

4-8

2

4-8

FRAME SIZE

LX - LW - LY

D5_355

D5_400

L

LZLX - LW - LY

LZ

755

755

820

820

820

820

AB

695

695

730

730

730

730

AD

1655

1725

1880

1980

1950

2000

LD

618

618

618

618

618

618

m

528

528

578

578

578

578

Z

550

620

580

580

650

650

W

75

100

75

75

100

100

D140

210

140

140

210

210

E20

29

20

20

28

28

F79,5

106

79,5

79,5

106

106

GAPOLES

2

4-8

SHAFT EXTENSION

Page 50: Motori Per Aree Pericolose

NOTES

48

Page 51: Motori Per Aree Pericolose

NOTES

45

Page 52: Motori Per Aree Pericolose

Gra

fich

e M

arco

lin S

chio

20

56

ASI.CT.028.2 GB MARELLI MOTORI reserves the right to change the design, technical specification and dimensions in order to update or improve its products, without prior notice.

Marelli Motori S.p.A.

Via Sabbionara, 1

36071 Arzignano (VI) Italy

(T) +39.0444.479711

(F) +39.0444.479888

www.fki-et.com/mm

[email protected]

Branches

Milan

(T) +39.02.66013166

(F) +39.02.66013483

Florence

(T) +39.055.431838

(F) +39.055.433351

U S AFKI Marelli-USA1524 Lebanon RoadDanville, KY 40422 - USA(T) +1.859.236.6600(F) +1.859.236.8877e-mail: [email protected]

G E R M A N YFKI Marelli - Central EuropeHeilswannenweg 5031008 Elze - Germany(T) +49.5068.462-400(F) +49.5068.462-409e-mail: [email protected]

S O U T H A F R I C AFKI Rotating Machines (Pty) LtdUnit 455 Activia Rd-Activia ParkElandsfontein, 1406GautengRepublic of South Africa(T) +27.11.8225566(F) +27.11.8288089e-mail: [email protected]

F R A N C EMarelli MotoriL’Atrium 4Rue du Colonel Chambonnet69500 Bron - France(T) +33.4.78602502(F) +33.4.78602737e-mail: [email protected]

G R E A T B R I T A I NAMCO MARELLI LtdMeadow LaneLoughboroughLeicesterLE 11 1NB(T) +44 1509.615518(F) +44 1509.615514e-mail: [email protected]

A S I A P A C I F I CFKI Energy Technology AP Sdn BhdLot 7, Jalan Majistret U1/26Hicom - Glenmarie Industrial Park40150 Shah AlamSelangor D.E., Malaysia(T) +60.3.7805.3736(F) +60.3.7803.9625e-mail: [email protected]

M a r e l l i M o t o r i o v e r s e a s o f f i c e s :

MarelliMotori S.p.A.

PART OF THE FKI GROUP OF COMPANIES

®