moving patients

32
Moving Patients Creating smoother transitions for immobile patients in the hospital Kirill Andreitšuk Fabien Bernard Mart Kekišev Patrick Mallon Kerstin Oppe 2014

Upload: design-engineering

Post on 12-Jan-2015

1.151 views

Category:

Design


6 download

DESCRIPTION

Medical Design project of Design & Engineering course. Autumn semester 2013/2014

TRANSCRIPT

Page 1: Moving Patients

Moving Patients!Creating smoother transitions for immobile patients in the hospital

Kirill Andreitšuk Fabien Bernard Mart Kekišev Patrick Mallon Kerstin Oppe

2014

Page 2: Moving Patients
Page 3: Moving Patients

Contents

01!02!03!05!06!07!09!10!11!12!19!22!23!25

profiles!general brief!

regionaal haigla!personas!

problem definition!market research!

design brief!concept sketches!

concept development!concept selection!

prototyping & testing!user feed back!

final design!technical drawings

Page 4: Moving Patients

Kerstin Oppe !BA interior architecture & furniture design [email protected]

Patrick Mallon!Bachelors of Architecture pjmallon.blogspot.com [email protected]

Fabien Bernard!MEng of Mechanical Engineering, Design & Ergonomics www.linkedin.com/pub/fabien-bernard/5b/57a/a33 [email protected] [email protected]

2014!

Kirill Andreitšuk!BSc (Bachelor in Science) in Mechanical Engineering, TUT, Production Engineering and Product Development [email protected]

Mart Kekišev!Bachelors of metal art and design artkek.carbonmade.com [email protected] !!

01

Page 5: Moving Patients

GeneralBrief

Hospital environments are designed from functional aspects to offer better treatment and

care. At the same time patients’ needs and expectations for privacy, personal dignity and

comfort have received little to no attention.

The aim of the project is to make patients’ hospital experience better by helping them feel less

vulnerable and more dignified in order to improve the quality of care.

Patient dignity

Patient safety

The aim of the project is to understand and test how design can be used to bring forward a better medical care in the hospital by approaching two subjects: patient safety and patient dignity

Human beings make mistakes mainly because the systems, tasks and processes they work in are poorly designed. Mistakes in hospital care are not unusual and could have very serious effects. !The aim of the project is to reduce number of errors within hospital care, make them easier to discover when they do happen and reduce the harmful effects of errors that do occur.

concept generation

problem definition

embodiment design and prototyping

testing with patients

research01

02

03

04

05

work structure

02

Page 6: Moving Patients

regionaal haigla

main !entrance

03

every workday…!3700 employees will come to work!1500 outpatient contact, incl. 250 emergencies!100-300 hospital admission/discharges!800-1000 patients treated as inpatients!up to 200 operations performed

ward floor plan

Average patient staying time in the hospital: 5 days

Page 7: Moving Patients

04

To be a recognised medical centre in Europe

To assure medical security to the Estonian population and health care system as a multi-profiled hospital providing acute care. To be in the forefront in t e a c h i n g , s c i e n t i fi c a n d developmental work in medicine and health care

hospital mission:

hospital vision:

Students of TUT Design and Engineering M.Sc. were invited to under take observat ional research at Perh Hospi ta l between the 19th and 23rd of September 2013 in the aims of to improving the areas of patient safety & dignity.

After attending a lecture given by the head surgeon we were informed that one of the biggest problems at the hospital was the continual need to move patients in and out of their beds and the difficulty in lifting them of the ambulance stretcher.

Page 8: Moving Patients

personasWe took our 2 personas from both ends of the process – a patient and a nurse. An important aspect

of this was to consider the behaviour and safety issues for both the performer and the passenger.

Nurse – Kristel 28

Kristel is a new worker in the hospital and thus is just getting to know the sy s tems o f tha t hosp i ta l . Her assignments are helping the ward with transporting patients from bed to wheelchair and back and transporting them to necessary locations.Issues

Regardless of her good general health, she has a high risk of back injury, because the lifting and moving of patients is done while her muscles are not warmed up to be resistant for strain. In these cases, it is quite easy to hurt herself while lifting a patient in a slightly wrong position. She would normally require the help of a bigger and stronger male ward assistant, but he is not always available. Because of this her shift at work is physically exhausting. what does she need?

We want to make her work in the hospital safer. Our goal is to change the heavy lifting of patients in a way that it becomes effortless for her and removes the most obvious possibilities for her to hurt herself. This way, her work will be easier and she will be less tired at the end of the shift.

Patient – Heli 71

Heli was taken to the hospital because of the severity of her joint pain. It has made her very hard and painful to move from her hips and legs. She is also in the hospital to get chemo therapy. This has made her a longer resident in the hospital. Above all, she misses being outdoors to see the sun and get fresh air instead of being in the ward all day with closed windows. Issues Currently she is transported around the hospital on her bed. The bed needs two assistants to move and takes a long time to navigate the big thing in the hallways. Putting her into a wheelchair is not an option due to her incapability of moving herself. She weighs about 90 kilos and would need 2 assistants to get her to move into the wheelchair. What does she need?We want her transport around the hospital not to need two assistants and for the whole process to be less space demanding. In addition to that, her capability of having progress in healing in any way is clearly dependent on her getting daily fresh air and sun, because it is healthy and it makes her happy. Right now, that is not possible, as it is not safe for her nor the nurses to lift her into a wheelchair, and a bed can not be transported outside. Our goal is to make it possible for her.05

Page 9: Moving Patients

problem definition

?

To explore current methods, cultures & technologies surrounding the lifting/moving of patients in the hospital, to identify inefficiencies and to propose creative solutions.

immobile patient

partially mobile patient

procedures &

operationsWC

examination room

washing & showering

Outside

patient lounge

patient journeys

06

“In a 2001 survey of some 5,000 nurses, 40 percent said they had been injured on the job, and 60

percent cited disabling back injuries as one of the culprits.”

American Nurses Association

“Patients are on average moved 4-5 times a day”

Jüri Tera, MD, FACS chief Oncological and General Surgical Centre

The need for patient-lifting equipment has grown in recent years. “What is happening nationally is that

patients are getting older, sicker and heavier Joan Forte, interim director of nursing at Stanford Hospital & Clinics

Page 10: Moving Patients

Sliding devices

mobile patient lift

07

static patient lift

chair bedbed chair

Page 11: Moving Patients

market research

barbers chair

massage chair

08

Research was conducted to determine the existence of products that moved patients in and out of their beds and around the hospital.!!An abundance of technological solutions were found to exist, ranging from engineering marvels such as a lifting robot donning a friendly bear exterior to a simple draw sheet that is placed underneath patients.!!Some of the devices on the market hinted possible dignity issues, (as what healthy individual is used to being hung in a bag)!!Other observations included the apparently awkward merging of technologies. A bed that could transform into unlikely chair, and a chair that could transform into an uncomfortable narrow bed, both provided useful guidance to design a product that was built from scratch for a specific purpose.!!The products which impressed us most were the draw sheet, for its ease of operation and minimal movement required of the patient, and other devices which aided the sliding motion such as a hover mat. We decided that this sliding motion would become a core of our design.!!Additional inspiration was also sought from other more static equipment, (massage chair, barber chair) as they provided some of the most ergonomic and smooth transitions. The obvious weight needed to ground these contraptions provided early concerns to whether we could engineer something that was comfortable, safe and still light enough to move around the hospital.!!Getting hands on with developing designs at university (see below) provided useful insights, but also reminded us that certain mechanisms were protected under copyright.!

chair research

Page 12: Moving Patients

Design BriefMaking the transportation of patients throughout the hospital safer for nurses and more comfortable for patients by improving the movement of the patients in and out of their ward bed.

To t r a n s f o r m t h e transport from bed to wheelchair safer for patients and staff by providing a device that demands no forced movements from the patient and minimal stress on the ward assistant.

conceptReducing physical stress for nurses & patients

09

Aim of the research: !To explore current methods, cultures & technologies surrounding the lifting/moving of patients in the hospital, to identify inefficiencies and to propose creative solutions. !!Research for the moving of patients has been divided into two main topics of enquiry: !(b2b) Bed to Bed : From the ambulance bed to the hospital/ examination bed in accident and emergency scenarios. !!(b2w) + (w2b) Bed to Wheelchair : The moving of conscious mobility impaired patients from their beds to wheelchair.

With emphasis on the swiftness & simplicity of the action

No forced movement required by the patient.

b2b - identified problems: !• High level of risk to patient due to lack

of information on the nature of injury. !• High levels of Physical strength required !• High number of staff required !• High degree of training required !• High level of risk of injury to both patient

and carers !• High level of pain for the patient !• Current technologies prohibitively

expensive and only designed for one use

b2w - identified problems: !• High numbers of staff required !• High tech mechanical solutions !• Low tech lifting/moving solutions require many trained

staff !• A degree of human error present and therefore patient

pain

Page 13: Moving Patients

fabric + rollers + static frame

10

concept sketches

Strong arm

searching for a pivot point

There was always the danger of creating an over engineered mechanical monstrosity lightness of touch was crucial

searching for a pivot point

It was established early o n t h a t p i s t o n technology was a sure w a y t o m a k e o u r product unnecessarily expensive and they were consciously left as a last option.

Page 14: Moving Patients

concept development

11

Most of the concept development focused on how many pivot points were necessary and where to place them. !We established from physical experience that a 90 degree lifting motion from the waist was uncomfortable for the patient, as the head moved such a long distance !Wheel designs were considered of secondary importance to transition movement and were designed at a later stage

Page 15: Moving Patients

concept selectionStress deformation and technical details

General mathematical information!In order to anticipate all necessary equations for each prototype, standard equations have been used. !Gravity Center!All CAD model are integrated in a 3D space, that is why, the gravity center is considered according to the axles X, Y and Z.

With i = the name of the part m = weight of the part v = volume of the part =density !This data is important for the mechanical aspect but also for the ergonomics aspect. Here, the human characteristics is essential. In this case, the mass ratio of the human body has to be known.

Prototype 1!To simplify our mathematical model, wheels and the brake system has not been modelled. The main static part is the support of the three pistons (and as well, of the wheels). !1) First solution, Static deformation (only in elastic area) in 90° wheelchair position.Modelled by Catia (with Manikin for having a real size in close relationship with standard data) Mathematical model and Stress deformation in mm (Von Mises criteria) by Ansys !Safety coefficient: 2 Maximal weight of patient: 150 kg Maximal load applied for this test: 3000 N Materiel used: Aluminium

12

Page 16: Moving Patients

2) Second solution, Static deformation (only in elastic area) in 130° wheelchair position. Modelled by Catia (with Manikin for having a real size in close relationship with standard data) Mathematical model and Stress deformation in mm (Von Mises criteria) by Ansys !Safety coefficient: 2 Maximal weight of patient: 150 kg Maximal load applied for this test: 3000 N -Leg part= 210N -Seat part= 2500N -Back part= 290N Materiel used: Aluminium

For dimensioning the size of the pistons, the system is simplified into 3 parts.

With: a=AB=300mm=0,3m b=BC=460mm=0,46m c=CD=950mm=0,95m !It is expected to find the Moment Force (N/m) on the points A, B, C and D. Immediately, the Moment Force in B is equivalent to 0 because it is fix (this mechanism turns around this point). !

With: F=m.g (g=9,81 m/s²) !Safety coefficient: 2

So:

Conclusion!In mechanics field, this solution works. So, the dimensioning of these three pistons, and the elbow part seems to be a good mechanical solution. The patient will have three possibilities: ! -bed position -wheel chair position (90°) -Transition position (here, team has decided to test a 130° angle (90+40)). !For the medical staff, the brake system can be control by the treadle or the hand system. The hydraulics system is sufficient and gives an easily help system to manipulate the patient with a very effort.

13

So:

Page 17: Moving Patients

The FEA has been carried out but with the same structure, the deformation is low and the system stays in the medical standard. Some parts have been removed and optimised. !Conclusion!This solution could be interesting b e c a u s e i t g i v e s t h e s a m e characteristics than before, but only manually. It will be more simple to make it and during the using, the nurse or the patient will not have any problem for use it.

This following picture shows the human weight repartition for each part (feet, legs, seat, back and head).

14

Prototype 2 !As it is precised before in this report, the solution with piston has to replace by a solution working only with human force. With this condition, two others idea and prototype has been imagined and designed. !The prototype 2 looks like the prototype 1 but without non-automatic piston (system cheaper, cleaner and with less maintenance). Additionally, it works with the famous rule of “the lever arm” reducing the human force and allowing to move a heavy patient. The following pictures show an overview and the autonomous pistons. The front wheels are not represented to simplify the finite elements analysis.

Page 18: Moving Patients

Prototype 3!This new prototype is radically different. The s ize i s the same bu t the mechanism is different and also adapted for the human force. It works with a classic lever arm but with two translations (explained afterward).

The following picture shows the mechanism with two Translation/rotation which are in close relation with the central pivot. !The seat can rotate between 0° and 2 1 , 6 ° c o r r e s p o n d i n g o n t h e comfortable standards. This solution is autonomous, in other words, the mechanism allow to control every part by one part. !If the leg part (pink part) moves, the seat part (blue part) and the back part (green part) will move automatically. But here, the green part will be the point control and the motion of the blue part and the pink part will be control by this way.

This following picture shows the human weight repartition for each part (feet,

legs, seat, back and head).

15

Page 19: Moving Patients

To control the motion!This mechanism is interesting because it could control by one point. Indeed, with two translation/rotation and three rotations, every parts is linked between them. The motion of the Back part will cause the motion of the seat part and the leg part. !1. By springs!!To control the motion, it is decided to add two springs for both l inks “translation/rotation”, so 4 springs in total. !Determination of the Spring size: !!It is remembered: !So:

By safety, for both it will be chosen 20 N/mm

With the standards, we can take a spring with k=20,01N/mm

2. By piston !This technical solution seems better and mainly safer. We propose to add one or two pistons on the back part. It will be linked between the top of the back part and the frame. It will be a double acting and it will give a safety condition for the transition motion between the chair and the bed position. !This characteristic is given by:

16

One piston version:

So:With F=2310N

P=10 Bar=1N/mm² !To select the piston, we need the radius:

It will be necessary to use a piston with a radius of 15,3mm and a

pressure of 10 Bar.

Page 20: Moving Patients

17

Locking part!In order to lock our system in wheelchair position, we have chosen the same mechanism used in a bus (for example) with the elbow support. The following picture shows you the principe between 0° and 180° but with our system, it will work only between 0° and 21,6°.

Ergonomics This part is essential, again more in a hospital environment. Take in consideration the human factor allows to optimize the system during the designing and the virtual production. This system is thought to optimize the comfort of the patient, the medical staff but as well for the hospital environment with the dimension of the room, the corridor and every displacements. !Bed position!The medical staff can move and walk without any difficulty and the patient has enough place on the bed to feel comfortable.

As it was explained previously, the prototype 3 has been chosen for few reasons. !-the mechanism and the kinematic are not the most simple but the system uses only one piston (or two, depends on the space available). !-the reduction of the help systems (like piston, electric devices etc) allows to keep the light weight. !-the reduction of the pneumatic or hydraulic system is in correlation with the hospital environment !-the cost of the maintenance will be low !-the production will be simple because it limits the waste of material and the shape is classic (weld system). !-the ergonomics part has been optimize for the patient, medical staff but for the hospital environment as well.

general conclusion

Page 21: Moving Patients

18

Free wheely1st iteration

Page 22: Moving Patients

prototyping & testing

Lifting motion

19

its possible to go from flat to sitting to flat with very little effort while laying on it

Aluminium was our preferred material, but steel is much easier to weld

Page 23: Moving Patients

prototyping & testing

proof of concept

connection details

20

The form is slightly suggestive of a capable four legged animal

Page 24: Moving Patients

Second iterationthe system appears ready for the patient to be slid over the support rails

21

simplified joints and locking mechanism on the proof of concept prototype

The handle now visible beneath the plywood

Page 25: Moving Patients

22

Things we learned from prototyping No major systems were changed, for the main concept of the mechanism worked in practice. The prototype was made of the joints we had on the spot and could make up ourselves, but in the real life, some simple additions like ball bearings on the frame rolls will make it move considerably swifter with less f r ict ion when moved f rom horizontal to seat position.

What was beautiful in our discoveries is how the wheely lifts the patient eye height up to almost a regular persons shoulder. This changes the whole experience of being transported around and interacting to people. The patient is no longer at hip height, as they would be in a bed or a wheelchair, but at a more accessible height that o ther peop le can more eas i l y communicate with. The behavioural change is evident from the early test..

lessons learned

behavioural changes

user feedback

Page 26: Moving Patients

23

The perfect ward assistant

Free wheely works in conjunction with a draw mat, or other patient sliding device, to efficiently slide a patient from the lying position on bed to Free wheely, once there the nurse can release the locks and the patient will be smoothly assume a commanding upright position ready to be moved around the hospital in comfort. Once there the process is reversed to complete a safe transition.

Page 27: Moving Patients

Lifting patients using the Free wheely to the sitting position (and visa versa) requires almost no effort from the nurses or patients and wheeling it around is just like any other device or baby stroller. Using this device, a patient who may have

had to stay in their beds can now be easily transported around the hospital and possibly even outside to benefit

from the healing benefits of fresh air and sunshine.

Free wheely

24

nurse handle

potential !IV drip post add on

cushioned seat, faux leather

patient hand rest,!thermo treated oak veneers

leg rest support fixed !to the frame for stability

Page 28: Moving Patients

25

ISO

draw

ing m

etho

d "E

"

Mate

rial:

Tole

ranc

eSc

ale

Wei

ght

Draw

n:Su

perv

isor

Date

K. An

drei

tshu

k

13.01

.2014

Title

Talli

nn U

niver

sity

of T

echn

olog

y

Dep

artm

ent

of M

echa

nical

Eng

inner

ingSh

eet

Draw

ing

Numb

er

u.o.n.

ISO

2786

-mK

132

Item

Numb

erDo

cume

nt N

umbe

rTi

tleMa

ss (I

tem)

Quan

tity

1FW

0001

.0001

Fram

e30

,382

kg1

2FW

0001

.0003

Slid

er47

,079

kg1

3FW

0001

.0002

Hand

le7,4

88 k

g1 84

,9 kg

1 : 10

Free

Whe

elie

Gen

eral

Arr

ange

ment

FW00

01.GA

1 / 1

Vert

ical P

ositi

on (1

:20)

Sittin

g Po

sitio

n (1:

20)

1061

684

1970

68°

110°

116°

105°

155°

588

1429

46 46

78

237

247

Prel

imin

ary

Draw

ing -

Not

Issu

ed f

or p

rodu

ctio

n

Page 29: Moving Patients

ISO

draw

ing

meth

od "

E"

Mate

rial:

Tole

ranc

eSc

ale

Wei

ght

Draw

n:Su

perv

isor

Date

K. An

drei

tshu

k

13.01

.2014

Title

Talli

nn U

nive

rsity

of

Tech

nolo

gy

Dep

artm

ent

of M

echa

nical

Eng

inner

ingSh

eet

Draw

ing N

umbe

r

u.o.n.

ISO

2786

-mK

1 : 10

Free

Whe

elie

Slid

er

FW00

01.00

031 /

1Pr

elim

inar

y Dr

awing

- N

ot Is

sued

for

pro

duct

ion

47,1

kg

2

9

1

64

83

5

710

1970

6278

1477

136

110°

116°

105°

155°

44

175

40

30

25

25

234,5

184

101

25

25

84,525

84,5

2525

198

130

53

570

220

880

1770

659

Item

Numb

erDo

cume

nt N

umbe

rTi

tleMa

teria

lQu

antit

y

1FW

0001

.0003

.02Fo

ot P

late

ABS

Plas

tic, m

edium

impa

ct1

2FW

0001

.0003

.04Hi

nge

Asse

mbly

8

3FW

0001

.0003

.07Sh

it Pl

ate

ABS

Plas

tic, h

igh

impa

ct1

4FW

.0001

.0003

.05Hi

p Pl

ate

ABS

Plas

tic, h

igh

impa

ct1

5FW

0001

.0003

.08To

rso

Plat

eAB

S Pl

astic

, hig

h im

pact

1

6FW

0001

.0003

.03He

ad P

late

ABS

Plas

tic, h

igh

impa

ct1

7SY

K-20

-TF

SKF

Bear

ing U

nitAs

semb

ly6

8FW

0001

.0003

.06Sh

aft

Stee

l, st

ruct

ural

3

9FW

0001

.0003

.01Br

acke

tAc

rylic

, hig

h im

pact

gra

de1

10DI

N933

A2

M10x

25Bo

ltA2

2

26

Page 30: Moving Patients

ISO

draw

ing

meth

od "

E"

Mate

rial:

Tole

ranc

eSc

ale

Wei

ght

Draw

n:Su

perv

isor

Date

K. An

drei

tshu

k

13.01

.2014

Title

Talli

nn U

niver

sity

of T

echn

olog

y

Dep

artm

ent

of M

echa

nical

Eng

inner

ingSh

eet

Draw

ing

Numb

er

u.o.n.

ISO

2786

-mK

30,4

kg1 :

10

Free

Whe

elie

Fra

me

FW00

01.00

011 /

1Pr

elim

inary

Dra

wing

- N

ot Is

sued

for

pro

duct

ion

A A

SECT

ION

A-A

2

118

4

107

5

3

Item

Numb

erTi

tleDo

cume

nt N

umbe

rMa

teria

lQu

antit

y

1Ma

in Be

amFW

0001

.0001

.04AI

SI31

62

2Bi

g Le

gFW

0001

.0001

.01AI

SI31

62

3Sm

all L

egFW

0001

.0001

.08AI

SI31

62

4Mi

d Be

amTu

be 5

0x50

x2AI

SI31

62

5Sh

imFW

0001

.0001

.07AI

SI31

64

6Ca

stor

Tent

e D1

50Pl

astic

4

7Ri

ght

Hold

erFW

0001

.0001

.06S3

55J2

R2

8Le

ft H

olde

rFW

0001

.0001

.03S3

55J2

R2

9Bo

ltDI

N933

A2

M10x

25A2

32

10Mi

d Ho

lder

FW00

01.00

01.05

S355

J2R

2

11Ha

ndle

Hol

der

FW00

01.00

01.02

S355

J2R

2

61 9

578

674

574

120°

120°

243,5

428

6725

660244,5B

VIEW

B

7717

8266306

1050

117

234

223

445

213

419

a3

2 2

u.o.n.

Cor

ner

weld

s -

u.o.n.

But

t we

lds

-

27

Page 31: Moving Patients

ISO

draw

ing

meth

od "

E"

Mate

rial:

Tole

ranc

eSc

ale

Wei

ght

Draw

n:Su

perv

isor

Date

K. An

drei

tshu

k

13.01

.2014

Title

Talli

nn U

niver

sity

of T

echn

olog

y

Dep

artm

ent

of M

echa

nical

Eng

inner

ingSh

eet

Draw

ing

Numb

er

u.o.n.

ISO

2786

-mK

1 : 5

Free

Whe

elie

Han

dle

FW00

01.00

021 /

1Pr

elim

inary

Dra

wing

- N

ot Is

sued

for

pro

duct

ion

7,5

kg

A ASE

CTIO

N A-

A

3

12

Item

Numb

erDo

cume

nt N

umbe

rTi

tleMa

teria

lQu

antit

y

1FW

0001

.0002

.02Be

amAI

SI31

62

2Fw

0001

.0002

.03Gr

ipS3

55J2

R1

3FW

0001

.0002

.01Ax

isS3

55J2

R1

500

20 20

5057

447

4

653

a3

a3

a3

2 2

u.o.n.

Cor

ner

weld

s -

u.o.n.

But

t we

lds

-

28

Page 32: Moving Patients

aitäh