ms-mp serie - rankin usa · 2013-09-04 · ms-mp serie 62 ordering system ms0/00-0adiffuse -...
TRANSCRIPT
DIMENSIONAL DRAWING
2422
588
18 4
M18
x1
80
48 22
M12
x15818 4
M18
x1
8012
10
126 58 4
M18
x1
80
M12
x1
5819,5 4
M18
x1
81,5
12
155
Ø10.5Ø8
12 58 4
M18
x1
80
6
135
Ø8
Ø10
.5
5818 4
M18
x1
80
58 4
M18
x1
80
126M12x1
Ø10.4
14,5
MS*/00-0A
1
8
11MS*/00-0B
11MS*/00-0C MS*/00-0D
8
299
11
8
3 4
8
11
5
8
MS*/00-0E MS*/00-1H
6
8
9 10
MS*/00-0K
7
89
8 810
MS*/00-0* MS*/00-1*
Key1 Axial cable exit 8 Red LED (output state MS2-4-6-C-P-D-R)
Red LED (supply/check MSE)
2 Axial cable exit with tang (1) 9 Tightening nut plastic housing
3 Right angle cable exit 10 Tightening nut metal housing (SW24)
4 Right angle cable exit with tang (1) 11 Cable 4(2)x0,34 mm2, Ø4,7mm, PVC, 2m
5 M12 plastic plug cable exit 6
6 M12 metal plug cable exit 6
7 M12 right angle plug cable exit 6
6 6 Connectors CD serie
6 6 Accessories ST serie
(1) Available only on request
MS-MP serie
60
SERIE MS-MP
M18 photoelectric sensors DECOUT®axial and with right angle optics - DC
� Wide range of models: diffuse, retro-reflective, polarized, through-beam detection and with background suppression
� Through-beam modelswith high sensing range
� Retro-reflective models with polarized light (with visible beam)
� Models with right angle optic (MP)� Models with fixed distance background suppres-
sion (MS0 and MS1)� 7 cable exit options to suit any installation� M12 plug cable exit in axial or right angle shape
(also available in all metal construction - MS)� Check available for all through-beam models� IP67 protection degree� Complete protection againts electrical damage� Wide range of connectors, accessories and
reflectors available
DIMENSIONAL DRAWING
2422
8
M12
x1
M18
x1
M12
x1
33,716,5 23,874
12
425
,3
29,3
M18
x1
33,716,5 23,874
425
,3
29,3
8
221 23
M12
x1
33,718 23,8
75,5
12
425
,3
29,3
33,716,5 23,8
74
8
425
,3
29,3
4 22
MP2/00-**
MP*/00-0A MP*/00-0E
MP*/00-0*
MP*/00-1A MP*/00-1H MP*/00-1*
16
8
8
1
55
26
5
2
8
73 74
57
5
Key1 Axial cable exit
2 M12 plug cable exit (plastic housing)
3 Axial cable exit (metal housing)
4 M12 plug cable exit (metal housing)
5 LED
6 Tightening nut plastic housing
7 Tightening nut metal housing (SW24)
8 Cable 4(2)x0,34 mm2, Ø4,7mm, PVC, 2m
6
6 Connectors CD serie
6 Accessories ST serie
6
6
2.1
catalogue4.fm Page 60 Tuesday, March 26, 2002 12:07 AM
photoelectric switches
61
New through-beam with high sensing rangeMS series keeps the first place in the market for the high distance which can be reached thanks to the introduction of new MSE-MSD through-beam with sensing range of 32m.
New polarized models with visible red lightMSP retro-reflective and polarized model represent the most suitable solution for correct detection of high reflecting targets.
Multifunctional output DECOUT®(NPN, PNP, NO, NC all in a single sensor)The first sensor with multifunctional output able to perform all output configurations thus reducing operating and stocking costs. M.D. creation which became a standardon the market for the high flexibility in all possibleapplications thanks to the decoupled output.
Plastic or metal housing
Cable exit in 7different versionsTo meet any installation need:
standard cable exit,standard cable exit with tang,
right angle cable exit,right angle cable exit with tang,
plastic and metal M12 axial plug cable exitand M12 right angle plug cable exit.
Wide range of modelswith high sensing rangediffuse 100, 200 and 400mm;retro-reflective 4m;polarized 3m;through-beam 16 and 32m (also availablewith check for the remote control of the system)new fixed distance 50 and 100mm background suppression.
The decoupled DECOUT®The multifunction output allows:
1) to perform all the 4 possible output configurations (NPN,PNP, NO, NC) without changing model.
2) to obtain logic control through series/parallel connectionsof different sensors without numerical restriction thus
reducing the number of employed inputs
2.1
catalogue4.fm Page 61 Tuesday, March 26, 2002 12:07 AM
MS-MP serie
62
ORDERING SYSTEM
M S 0 / 0 0 - 0 A diffuse - retro-reflective - background suppression
serie cable exitM18 DECOUT® photoelectric sensor MS A axial cable exitM18 photoelectric sensor with right angle optic MP B (2) axial cable exit with tang
model C (3) right angle cable exit50mm backgroung suppression (1) 0 D (2)(3) right angle cable exit with tang100mm backgroung suppression (1) 1 E M12 plug cable exit (plastic housing)100mm diffuse reflection 2 H M12 plug cable exit (metal housing)200mm diffuse reflection 4 K (3) M12 right angle plug cable exit400mm diffuse reflection 6 housing4m retro-reflective C 0 plastic housing3m polarised retro-reflective P 1 metal housing
output stateNO/NC output state 0 (1) The background suppression are available
on MS serie only. (2) Available only on request.(3) Not available on MP serielogic
NPN/PNP output type 0
SPECIFICATIONSModel M*0/**-** M*1/**-** M*2/**-** M*4/**-** M*6/**-** M*C/**-** M*P/**-**Type diffuse reflection retro-reflective
background suppression standard standard polarizedNominal sensing distance(Sn) 50mm (1) 100mm (1) 100mm (1) 200mm (1) 400mm (2) 4m (3) 3m (3)
Emission infrared (880nm) red (660nm)Tolerance 0...+10% Sn +15/ -10% SnDifferential travel ≤5% ≤10%Repeat accuracy 5%Operating voltage 10 - 30 VdcRipple ≤10 %No-load supply current 40mA 30mALoad current ≤100 mALeakage current ≤ 10µAVoltage drop 1,2V max. IL=100mAOutput type DECOUT® (NPN, PNP, NO, NC)Switching frequency 80HzTime delay before availability 200 msSupply electrical protections transientOutput electrical protections short circuit (with hold)Temperature range -25°....+70°C (without freeze) -25°....+60°CTemperature drift 5% ≤10% SrInterference to external light 3000 lux (incandescent lamp), 10000 lux (sunlight)Protection degree (DIN 40 050) IEC IP67LED indicators red (output energized)Housing material PBT (plastic housing),nickel-plated brass (metal housing), polycarbonate (cable exit)Lenses material plexiglas 7NTightening torque 40Nm (metal housing)Weight (approx.) 150g(1) with 100x100mm white matt paper; (2) with 100x100mm white matt paper; (3) with standard reflector Ø80mm (RL110 supplied seperately).
CONNECTORSM12 (emitters) M12 (emitters with check) M12
( - )
( + )
34
21
( - ) check
( + ) check
34
21
( - )
( + )
OUT ( - ) Supply ( ± )
Supply ( ± ) OUT ( + )
34
21
2.1
catalogue4.fm Page 62 Tuesday, March 26, 2002 12:07 AM
photoelectric switches
63
ORDERING SYSTEM
M S E / 0 0 - 0 A through-beam
serie cable exitM18 DECOUT® photoelectric sensor MS A axial cable exitM18 photoelectric sensor with right angle optic MP B (1) axial cable exit with tang
model C (2) right angle cable exitstandard emitter E D (1)(2) right angle cable exit with tangstandard receiver 16m R E M12 plug cable exit (plastic housing)high distance receiver 32m D H M12 plug cable exit (metal housing)
output state K (2) M12 right angle plug cable exitstandars emitter / DECOUT® output 0 housingemitter with check X 0 plastic housing
logic 1 metal housingDECOUT® output / emitter 0
(1) Available only on request.
(2) Not available on MP serie.
SPECIFICATIONSModel M*E/**-** and M*R/**-** M*E/**-** and M*D/**-**Type through-beam
standard high distanceNominal sensing distance(Sn) 16m 32mMinimum detectable object Ø7,5mmEmission infrared (880nm)Tolerance see Sr (glossary)Differential travel ≤10%Repeat accuracy 5%Operating voltage 10 - 30 VdcRipple ≤10 %No-load supply current 15mA (emitter), 35mA (emitter with check), 25mA (receiver)Load current ≤100 mALeakage current ≤ 10µAVoltage drop 1,2V max. IL=100mAOutput type DECOUT® (NPN, PNP, NO, NC)Switching frequency 30HzTime delay before availability 200 msSupply electrical protections transientOutput electrical protections short circuit (with hold)Temperature range -25°....+70°C (without freeze)Temperature drift 10% SrInterference to external light 3000 lux (incandescent lamp), 10000 lux (sunlight)Protection degree (DIN 40 050) IEC IP67LED indicators red (output energized)Housing material PBT (plastic housing),nickel-plated brass (metal housing), polycarbonate(cable exit)
Lenses material plexiglas 7NTightening torque 40Nm (metal housing)Weight (approx.) 250g
WIRING DIAGRAMSDECOUT® output emitter with MSE/X0
In case of comboned load, the maximum admissible capacity C = 68nF, for max. output voltage and current. See Description on technical terms.
Z
T
TD
FC
NPN - NO
WH/2
BK/4
BN/1
BU/3
WH/2
BK/4
BU/3
BN/1
NPN - NC
NPN out
D
WH/2
BK/4
BU/3
BN/1PNP - NO
NPN out PNP out WH/2
BK/4
BU/3
BN/1
PNP - NC
PNP out
R4.7K
CHECK input4,5...30Vdc
FC
BK/4
BN/1
BU/3
WH/2
2.1
catalogue4.fm Page 63 Tuesday, March 26, 2002 12:07 AM
CHARACTERISTIC CURVESBackground suppression Background suppression Excess gain Parallel displacement
MS0
MS1
M*2
M*2
Gain
Gain
Gain
Dist
ance
Y (
mm
)
Distance (mm) Distance (mm) Distance (mm) Distance X (mm)
Distance / target size Excess gain Parallel displacement Distance / target size
M*2
M*4
M*4
M*4
Dis
tanc
e Xo
n(m
m)
Gain
Dist
ance
Y (
mm
)
Dis
tanc
e Xo
n(m
m)
Target dimension (mm) Distance (mm) Distance X (mm) Target dimension (mm)
Excess gain Parallel displacement Distance / target size Excess gain
M*6
M*6
M*6
M*C
Gai
n
Dis
tanc
e Xo
n(m
m)
Dist
ance
Xon
(m
m)
Gain
)
Distance X (mm) Target dimension (mm) Target dimension (mm) Distance X (cm)
Parallel displacement Excess gain Parallel displacement Excess gain
M*C
M*P
M*P
M*E
- M
*R
Dis
tanc
e Y
(mm
)
Gain
Dist
ance
Y (
mm
)
Gain
Distance X (m) Distance X (m) Distance X (mm) Distance X (m)
Parallel displacement Angular displacement Mutual interference Excess gain
M*E
- M
*R
M*E
- M
*R
M*E
- M
*R
M*E
- M
*D
Dis
tanc
e Y
(mm
)
Dist
ance
X (
m)
Dis
tanc
e Y
(mm
)
Gain
Distance X (m) Angle (°) Distance X (m) Distance X (m)
Parallel displacement Angular displacement Mutual interference
M*E
- M
*D
M*E
- M
*D
M*E
- M
*D
Dis
tanc
e Y
(mm
)
Dist
ance
X (
m)
Dis
tanc
e Y
(mm
)
Distance X (m) Angle (°) Distance X (m)
1 101
10
100
Bianco 90%
Nero 6%
50
White 90%
Black 6%
0,1 1 10 1001
10
100
White 90%
Black6%
1 10 100 10000,1
1
10
100
0 20 40 60 80 100-10
0
10
0 50 10030
60
70
80
90
100
110
1 10 100 10000,1
1
10
100
0 40 80 120 160 200-20
-10
0
10
20
0 50 100 15030
40
50
60
70
80
90
100
110
1 10 100 10000,1
1
10
100
1000
0 100 200 300 400 500-20
-10
0
10
20
0 50 100 150 20030
40
50
60
70
80
90
100
110
0 100 200 300 400 500 600 7000,1
1
10
100
0 1 2 3 4 5 6-100
-80
-60
-40
-20
0
20
40
60
80
100
0 1000 2000 3000 4000
1
10
0 1000 2000 3000 4000-40
-20
0
20
40
0 4 8 12 16 20 241
10
100
1000
0 4 8 12 16 20 24-600
-400
-200
0
200
400
600
-20 -10 0 10 200
4
8
12
16
20
24
0 5 10 15 20200
400
600
800
1000
1200
Operating area
Interference area
0 10 20 30 401
10
100
0 5 10 15 20 25 30 35 40 45 50-1500
-1000
-500
0
500
1000
1500
-20 -10 0 10 200
5
10
15
20
25
30
35
40
45
50
0 5 10 15 20 25 30 35400
800
1200
1600
2000
Operating area
Interference area
MS-MP serie
64
2.1
catalogue4.fm Page 64 Tuesday, March 26, 2002 12:07 AM