MSM Software Feature Difference Between the MRController and the IR Controller

Systems Engineering Note

S11252, Version 1.0March 2015

DB05-000341-00

Page 2: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

For a comprehensive list of changes to this document, see the Revision History.

Avago, Avago Technologies, the A logo, LSI, Storage by LSI, MegaRAID, MegaRAID Storage Manager, CacheCade, SSD Guard, and SafeStore are trademarks of Avago Technologies in the United States and other countries. All other brand and product names may be trademarks of their respective companies.

Data subject to change. Copyright © 2015 Avago Technologies. All Rights Reserved.

Corporate Headquarters Email Website

San Jose, CA [email protected] www.lsi.com

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Page 3: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Table of Contents

Avago Technologies Confidential- 3 -

Table of Contents

MSM Software Feature Difference Between the MR Controller and the IR Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 MegaRAID Storage Manager Main Menu Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2.1 Dashboard View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42.2 Physical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.3 Logical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.4 Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3 Creating a New Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.1 Creating a Virtual Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4 Monitoring Controllers and Their Attached Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154.1 Managing Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154.2 Managing Drive Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174.3 Managing Virtual Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174.4 Managing Physical Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194.5 Managing Battery Backup Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

5 Finding Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

6.1 Version 1.0, March 2015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Page 4: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 4 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

OverviewDashboard View

MSM Software Feature Difference Between the MR Controller and the IR Controller

1 Overview

This document provides an overview of MegaRAID Storage Manager® software feature differences between the MegaRAID® (MR) controller and the Integrated RAID (IR) controller.

2 MegaRAID Storage Manager Main Menu Windows

2.1 Dashboard View

The following table and the figures describe the dashboard view differences in the MR and IR controller.

Table 1 Dashboard View – MR Controller Versus IR Controller

MR Controller IR Controller

Displays the Bus ID, Device ID, and Domain ID of the controller. If the controller supports High Availability DAS, the HA Peer Controller Status field appears.

Displays the Bus ID and the Device ID of the controller.

NOTE The Domain ID of the controller is not displayed.

NOTE High Availability DAS is not supported in IR controllers.

The MegaRAID Advanced Software Options are enabled. NOTE The MegaRAID Advanced Software Options are disabled.

Allows you to perform operations, such as Create Virtual Drive, Create CacheCade® - SSD Caching, Load Configuration, Update Firmware, and Silence alarm.

You can perform operations, such as Create Virtual Drive, Load Configuration, and Update Firmware.

NOTE The Silence Alarm and Create CacheCade - SSD Caching features are not supported.

Link to the MR online help. Link to the IR online help.

Page 5: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 5 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsDashboard View

Figure 1 Dashboard View - MR Controller

Figure 2 Dashboard View - IR Controller

Page 6: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 6 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsPhysical View

2.2 Physical View

The following table and figures describe the physical view differences in the MR and IR controller.

Table 2 Physical View – MR Controller Versus IR Controller

MR Controller IR Controller

Displays the Bus ID, Device ID, and Domain ID of the controller. If the controller supports High Availability DAS, an additional parent mode, Server Domain, appears on the device tree in the Physical tab.

Displays the Bus ID and the Device ID of the controller.

NOTE The Domain ID of the controller is not displayed.

NOTE High Availability DAS is not supported.

The Properties tab displays the following properties for a controller: General properties, such as NVRAM information, BIOS version,

Flash size, memory size, Shield state, and chip temperature, and so on.

Shield State is supported Power State Properties Data Protection Properties Firmware Properties Drive Security Properties Background Operation Properties Emergency Spare Properties

The Properties tab displays the limited properties for a controller: General properties, such as NVRAM information, BIOS version, Flash

size, memory size, Shield state, and chip temperature, and so on. Firmware Properties Drive Security Properties

The Properties tab displays the following properties for an enclosure: Vendor ID Enclosure ID Serial Number Enclosure Model Enclosure Location Connector Information Number of Slots Production Revision Level Number of Fans Number of Power Supplies Number of Voltage Sensors.

The Properties tab displays the following properties for an enclosure: Vendor ID Serial Number Number of Slots Production Revision Level Number of Fans Number of Power Supplies Number of Voltage Sensors

NOTE Enclosure Model, Enclosure ID, Enclosure Location, and Connector information are not displayed.

Page 7: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 7 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsPhysical View

Figure 3 Physical View –Controller Properties – MR Controller

Figure 4 Physical View – Controller Properties – IR Controller

Page 8: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 8 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsPhysical View

Figure 5 Physical View – Enclosure Properties – MR Controller

Figure 6 Physical View – Enclosure Properties – IR Controller

Page 9: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 9 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsLogical View

2.3 Logical View

The following table and figures describe the logical view differences in the MR and IR controller.

Figure 7 Logical View – MR Controller

Table 3 Logical View – MR Controller Versus IR Controller

MR Controller IR Controller

Displays the Bus ID, Device ID, and Domain ID of the controller. If the controller supports High Availability DAS, an additional parent mode, Server Domain, appears on the device tree in the Logical tab.

Displays the Bus ID and the Device ID of the controller.

NOTE The Domain ID of the controller is not displayed.

NOTE High Availability DAS is not supported.

The Properties tab displays the following properties for a controller: General properties, such as NVRAM information, BIOS version,

Flash size, memory size, shield state, and chip temperature, and so on.

Power State Properties Data Protection Properties Firmware Properties Drive Security Properties Background Operation Properties Emergency Spare Properties

The Properties tab for a controller displays limited properties for a controller: General properties, such as NVRAM information, BIOS version, Flash size,

memory size, shield state, and chip temperature, and so on. Firmware Properties Drive Security Properties

Page 10: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 10 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

MegaRAID Storage Manager Main Menu WindowsMenu Options

Figure 8 Logical View – IR Controller

2.4 Menu Options

The following table describes the main menu differences in the MR and IR controller.

Table 4 Menu Options– MR Controller Versus IR Controller

MR Controller IR Controller

The Manage menu displays the following options: Refresh Server Check Consistency Initialize Show Progress Exit

The Manage menu displays the following options: Refresh Server Check Consistency

NOTE Check Consistency is supported. However, it is enabled when the background initialization (BGI) is completed.

Show Progress Exit

NOTE The Initialize feature is not supported.

The Go To menu displays the following options: Controller Drive Group Physical Drive Virtual Drive BBU

The Go To menu displays the following options: Controller Drive Group Physical Drive Virtual Drive

NOTE The BBU feature is not supported.

Page 11: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 11 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Creating a New ConfigurationCreating a Virtual Drive

3 Creating a New Configuration

3.1 Creating a Virtual Drive

The following table and figures describe the virtual drive configuration differences in the MR and IR controller.

Table 5 Create Virtual Drive – MR Controller Versus IR Controller

MR Controller IR Controller

Simple Configuration You can use the free capacity of an existing drive group or

unconfigured drives for creating a configuration. MR controller supports RAID levels 0, 1, 5, and 6. Drive type mixing is allowed. You can assign an unconfigured drive as a hot spare during

volume creation. Drive security (Avago SafeStore™ Data Security Service) is

supported. If High Availability DAS is supported on the controller and

you are creating a virtual drive using simple configuration, by default, the virtual drive is shared with the other servers in that cluster.

See Figure 9.

Simple Configuration

NOTE The system creates the best configuration possible using the available drives.

NOTE IR controller supports RAID levels 0, 1, 10, and 1E.

NOTE Drive type mixing is not allowed.

NOTE Drive security ((Avago SafeStore™ Data Security Service)) is not supported.

NOTE High Availability DAS is not supported.

See Figure 10.

Advance Configuration You can create Spanned drive groups. MR controller supports RAID levels 0, 1, 5, 6, 10, 50, and 60. Drive security (Avago SafeStore™ Data Security Service) is

supported. You can set the following virtual drive settings:

— Virtual drive name— Initialization state— Strip Size— Read policy— Write policy— I/O policy— Access policy— Disk Cache policy

NOTE After you create the virtual drive, you cannot change Initialization state and Stripe size settings.

If the controller supports High Availability DAS, the Provide Shared Access option enables you to share the virtual drive to between the two servers in a cluster.

You can enable or disable SSD Caching on the new virtual drive.

See Figure 11 and Figure 13.

Advance Configuration

NOTE You cannot create Spanned drive groups.

NOTE IR controller supports RAID levels 0, 1, 10, and 1E.

NOTE Drive security ((Avago SafeStore™ Data Security Service)) is not supported.

NOTE All of the parameters except the virtual drive name in the virtual drive settings window are disabled. After you create the virtual drive, you can only change the Disk cache policy.

NOTE High Availability DAS is not supported.

NOTE SSD Caching feature is not available.

See Figure 12 and Figure 14.

Page 12: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 12 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Creating a New ConfigurationCreating a Virtual Drive

Figure 9 Create Virtual Drive (Simple) - MR Drive Group Window

Figure 10 Create Virtual Drive (Simple) - IR Drive Group Window

Page 13: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 13 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Creating a New ConfigurationCreating a Virtual Drive

Figure 11 Create Virtual Drive (Advance) - MR Drive Group Window

Figure 12 Create Virtual Drive (Advance) - IR Drive Group Window

Page 14: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 14 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Creating a New ConfigurationCreating a Virtual Drive

Figure 13 Create Virtual Drive (Advance) - MR Virtual Drive Settings Window

Figure 14 Create Virtual Drive (Advance) - IR Virtual Drive Settings Window

Page 15: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 15 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Monitoring Controllers and Their Attached DevicesManaging Controllers

4 Monitoring Controllers and Their Attached Devices

4.1 Managing Controllers

The following table and figures describe the controller operations differences in the MR and IR controller.

Table 6 Managing Controller – MR Controller Versus IR Controller

MR Controller IR Controller

You can perform the following controller operations: Create Virtual Drive Diable Alarm Silence Alarm Start Patrol Read Set Patrol Read Properties Disable SSD Guard™ Scan Foreign Configuration Save Configuration Clear Configuration Set Consistency Check Properties Schedule Consistency Check Set Adjustable Task Rates Manage Power Save Settings Update Controller Firmware Manage MegaRAID Advanced Software Options Manage Link Speed Save TTY Log

You can perform the following controller operations: Create Virtual Drive Scan Foreign Configuration Load Configuration Save Configuration Clear Configuration Update Controller Firmware

Page 16: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 16 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Monitoring Controllers and Their Attached DevicesManaging Controllers

Figure 15 Managing Controller - MR Controller

Figure 16 Managing Controller - IR Controller

Page 17: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 17 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Monitoring Controllers and Their Attached DevicesManaging Drive Groups

4.2 Managing Drive Groups

The following table and figures describe the drive group configuration differences in the MR and IR controller.

Figure 17 RAID Level Migration - MR Controller

4.3 Managing Virtual Drives

The following table and figures describe the virtual drive operations differences in the MR and IR controller.

Table 7 Managing Drive Group– MR Controller Versus IR Controller

MR Controller IR Controller

You can perform the following drive group operations: Modify Drive Group. RAID Level Migration.

NOTE RAID Level Migration is not supported.

Table 8 Managing Virtual Drives – MR Controller Versus IR Controller

MR Controller IR Controller

You can perform the following virtual drive operations: Rename Virtual Drive Delete Virtual drive Set Virtual Drive Properties Start and Stop Locating Virtual Drive Start Initialization Virtual Drive Erase Hide Virtual Drive

You can perform the following virtual drive operations: Delete Virtual drive Set Virtual Drive Properties Start and Stop Locating Virtual Drive

Page 18: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 18 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Monitoring Controllers and Their Attached DevicesManaging Virtual Drives

Figure 18 Managing Virtual Drives - MR Controller

Figure 19 Managing Virtual Drives - IR Controller

Page 19: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 19 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Monitoring Controllers and Their Attached DevicesManaging Physical Drives

4.4 Managing Physical Drives

The following table and figures describe the physical drive operations differences in the MR and IR controller.

Figure 20 Managing Physical Drives - MR Controller

Table 9 Managing Physical Drives– MR Controller Versus IR Controller

MR Controller IR Controller

You can perform the following physical drive operations: Assign Global Hot Spare Assign Dedicated Hot Spare Start and Stop Locating Drive Prepare for Removal Drive Erase Make JBOD

NOTE If the JBOD feature is enabled, you can make an unconfigured drive as a JBOD.

You can perform the following physical drive operations: Assign Global Hot Spare Start and Stop Locating Drive

NOTE JBOD feature is not supported

Page 20: MSM Software Feature Difference Between the MR … · MSM Software Feature Difference Between the MR Controller and the IR ... 3 Creating a New Configuration ... Start Patrol

Avago Technologies Confidential- 20 -

MSM Software Feature Difference Between the MR and the IR ControllersMarch 2015

Finding Additional InformationManaging Battery Backup Units

Figure 21 Managing Physical Drives - IR Controller

4.5 Managing Battery Backup Units

5 Finding Additional Information

In addition to this guide, refer the 12Gb/s MegaRAID® SAS Software User Guide for more information on the MegaRAID Storage Manager software features.

6 Revision History

6.1 Version 1.0, March 2015

Initial document release.

Table 10 Managing Battery Backup Units – MR Controller Versus IR Controller

MR Controller IR Controller

You can perform the following battery backup unit operations: Set Learn Cycle Properties. Start a Learn Cycle Manually.

You cannot connect a battery backup unit to an IR controller.